• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 63
  • 61
  • 49
  • 47
  • 39
  • 38
  • 28
  • 27
  • 26
  • 18
  • 17
  • 15
  • 15
  • 15
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utiliza??o de m?todos de decomposi??o emp?ricos no pr?-processamento de dados de resson?ncia magn?tica funcional

Esper, Nathalia Bianchini 31 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-09-22T11:11:06Z No. of bitstreams: 1 DIS_NATHALIA_BIANCHINI_ESPER_COMPLETO.pdf: 4985859 bytes, checksum: 25572c47a501b6fd792c5a3384b19891 (MD5) / Made available in DSpace on 2016-09-22T11:11:06Z (GMT). No. of bitstreams: 1 DIS_NATHALIA_BIANCHINI_ESPER_COMPLETO.pdf: 4985859 bytes, checksum: 25572c47a501b6fd792c5a3384b19891 (MD5) Previous issue date: 2016-03-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Functional Magnetic Resonance Imaging is a noninvasive technique used to map and explore brain networks through the changes in the oxyhemoglobin concentration that is caused by neural activity. One of the techniques to evaluate and measure these brain funcions is resting-state fMRI, which is indicated to subjects with some degree of neurological impairment since no cognitive task is necessary. The main problem of this exam is that it is more sensitive to noise during scanning - from physiological sources, for example, such as heart beating and breathing. The most common and hardest to correct is noise caused by a subject?s head movement. Given this fact, the objective of this thesis is to study and evaluate the effectiveness of implement empirical decomposition methods in the preprocessing stage of fMRI data. Empirical Mode Decomposition and Empirical Mean Curve Decomposition were the chosen algorithms because of their use in non-stationary and nonlinear signals. Thirty-three children participating in the ACERTA Project were classified in two groups: good readers (14 subjects) and poor readers (19 subjects). These data were submitted to five different preprocessing strategies: two for the usual preprocessing steps using or not the movements censoring; one for the Empirical Mode Decomposition method; and two for the Empirical Mean Curve Decomposition, being that one strategy uses changes proposed in this work in original algorithm. According to statistical analysis, the Empirical Mean Curve Decomposition, both the original and the modified, proved to be a promissing method for noise reduction in real fMRI data. / A t?cnica de imagem por resson?ncia magn?tica funcional ? um exame n?o invasivo que permite mapear e explorar diversas fun??es cerebrais por meio de varia??es na concentra??o de oxi-hemoglobina nas regi?es de atividade neural. Uma das t?cnicas para avaliar e mapear essas fun??es cerebrais ? o exame em estado de repouso, que ? mais indicado em pacientes/volunt?rios que tenham algum tipo de problema neurol?gico, pois n?o faz o uso de tarefas cognitivas para gerar as imagens de mapeamento cerebral. O principal problema desse exame ? ser muito sens?vel aos diferentes tipos de ru?do presentes ao longo do exame, como os de origem fisiol?gica, principalmente provenientes da respira??o e dos batimentos card?acos. O tipo de ru?do mais comum e que mais afeta os dados ? causado pela movimenta??o da cabe?a do paciente/volunt?rio. Pensando nisso, esta disserta??o tem como objetivo estudar e avaliar a efic?cia da utiliza??o de m?todos emp?ricos de decomposi??o durante a etapa de pr?-processamento para a redu??o de ru?do em dados oriundos de exames por resson?ncia magn?tica funcional. Os algoritmos escolhidos foram o de Decomposi??o em Modos Emp?ricos e o de Decomposi??o Emp?rica da Curva M?dia. Esses algoritmos foram escolhidos por serem utilizados em sinais n?o-estacion?rios e n?o-lineares. Este estudo foi realizado com 33 crian?as do Projeto ACERTA (Avalia??o de Crian?as do Risco de Transtornos de Aprendizagem) classificadas em dois grupos: bons leitores (14 crian?as) e maus leitores (19 crian?as). Estes dados foram submetidos a cinco diferentes estrat?gias de pr?-processamento: duas para as etapas usuais de pr?-processamento utilizando ou n?o a etapa de censura dos movimentos; uma para o m?todo de Decomposi??o em Modos Emp?ricos; e duas para o m?todo de Decomposi??o Emp?rica da Curva M?dia, sendo que uma estrat?gia utiliza altera??es no algoritmo original propostas por este trabalho. De acordo com as an?lises estat?sticas realizadas, o algoritmo de Decomposi??o Emp?rica da Curva M?dia, tanto o original quanto o modificado, mostrou ser um m?todo promissor para a redu??o de ru?do nos dados reais de fMRI.
2

Estudo Computacional de Biochip em Fibra ?ptica Baseado na Resson?ncia de Pl?smons de Superf?cie

Vicente, Mauricio 06 May 2017 (has links)
Submitted by Alex Sandro R?go (alex@ifpb.edu.br) on 2017-06-06T12:00:22Z No. of bitstreams: 1 32- Mauricio Vicente - ESTUDO COMPUTACIONAL DE BIOCHIP EM FIBRA ?PTICA BASEADO NA RESSON?NCIA DE PL?SMONS DE SUPERF?CIE.pdf: 2764637 bytes, checksum: 32348af8b12e2c07b56a0ffc0014865a (MD5) / Approved for entry into archive by Alex Sandro R?go (alex@ifpb.edu.br) on 2017-06-06T12:04:04Z (GMT) No. of bitstreams: 1 32- Mauricio Vicente - ESTUDO COMPUTACIONAL DE BIOCHIP EM FIBRA ?PTICA BASEADO NA RESSON?NCIA DE PL?SMONS DE SUPERF?CIE.pdf: 2764637 bytes, checksum: 32348af8b12e2c07b56a0ffc0014865a (MD5) / Made available in DSpace on 2017-06-06T12:04:04Z (GMT). No. of bitstreams: 1 32- Mauricio Vicente - ESTUDO COMPUTACIONAL DE BIOCHIP EM FIBRA ?PTICA BASEADO NA RESSON?NCIA DE PL?SMONS DE SUPERF?CIE.pdf: 2764637 bytes, checksum: 32348af8b12e2c07b56a0ffc0014865a (MD5) Previous issue date: 2017-05-06 / O fen?meno de Resson?ncia de Pl?smons de Superf?cie (RPS) tem sido utilizado para a produ??o de biossensores por apresentar vantagens, como a possibilidade de miniaturiza??o, baixo custo, alta sensibilidade, alta seletividade e velocidade de resposta. Este trabalho tem como objetivo realizar um estudo computacional dos biossensores RPS em fibra ?ptica convencional (s?lica e/ou pol?mero). Neste caso, a casca da fibra ? removida na regi?o sensora, e o n?cleo ? recoberto por uma camada fina de metal, formando o biochip ?ptico. A an?lise computacional ? realizada com o aux?lio do software MATLAB, em que foi implementado o modelo de multicamadas de Fresnel, e o software COMSOL Multiphysics, baseado no m?todo dos elementos finitos, para a modelagem do biochip. O objetivo ? modificar e investigar os par?metros geom?tricos (dimens?es da fibra, espessura da camada met?lica) e eletromagn?ticos (comprimento de onda, ?ndice de refra??o, ?ngulo de incid?ncia, dentre outros) do biochip. Al?m disso, o tipo de metal utilizado ? de fundamental import?ncia, uma vez que sua oxida??o pode implicar na diminui??o do desempenho do biossensor, em contato com o analito (solu??o aquosa). O uso de metais nobres, como Ouro e Prata, na configura??o do biossensor oferece bons resultados, observados por meio dos valores de FWHM e refletividade, tanto para a ocorr?ncia do fen?meno RPS, quanto ao se analisar os par?metros de desempenho do biossensor. An?lises foram realizadas utilizando os modos de interroga??o angular e espectral. Por fim, tamb?m s?o consideradas configura??es de biochip com camadas de grafeno dispostas nas interfaces metal-fibra e metal-analito, com o fito de estudar a possibilidade de aumento da transmissividade do campo el?trico evanescente. Os resultados das an?lises s?o mostrados e discutidos.
3

Estudo da rela??o da obesidade na adolesc?ncia com altera??es da conectividade cerebral por resson?ncia magn?tica funcional em estado de repouso

Paganin, Ricardo Pessini 31 July 2017 (has links)
Submitted by PPG Pediatria e Sa?de da Crian?a (pediatria-pg@pucrs.br) on 2018-01-02T10:55:20Z No. of bitstreams: 1 Dissertac?a?o final Ricardo Paganin.pdf: 1872920 bytes, checksum: 7d8831f2c8ed4551b8e0568cd2551272 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-01-22T13:24:28Z (GMT) No. of bitstreams: 1 Dissertac?a?o final Ricardo Paganin.pdf: 1872920 bytes, checksum: 7d8831f2c8ed4551b8e0568cd2551272 (MD5) / Made available in DSpace on 2018-01-22T13:34:41Z (GMT). No. of bitstreams: 1 Dissertac?a?o final Ricardo Paganin.pdf: 1872920 bytes, checksum: 7d8831f2c8ed4551b8e0568cd2551272 (MD5) Previous issue date: 2017-07-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction: Obesity in childhood and adolescence represents a concerning healthcare issue, being considered a global epidemic by the World Health Organization and an important risk factor for adulthood obesity. The neurocognitive mechanisms that lead to obesity are still poorly understood, however new studies based on Functional Magnetic Resonance (FMR) including adult patients have revealed altered connectivities between obese and non-obese patients, which include reward related mechanisms and self control circuits. Nonetheless, these differences are not consistently studied in obese children and adolescents. Objective: To demonstrate possible differences of functional connectivity between obese adolescents and controls evaluated with Resting State FMR (RSFMR). Method: Data was obtained from 38 patients, aged between 15 and 18 years old, 16 in the obese group and 22 in the control group. The subjects underwent RSFMR, and also abdominal MR for the quantification of visceral adiposity. Body Mass Index (BMI data was also obtained. Using AFNI software, Z score maps of functional connectivity were obtained from regions of interest located in the amygdalae, posterior cingulate cortex and bilateral pre frontal cortex. These maps were correlated using t test and multiple regression analysis to the BMI and visceral adiposity data, considering a corrected p value of <0.05. Results: Group analysis showed no significant differences between obese and control patients. Multiple regressions analysis also showed no significant results with BMI data. However, multiple regression analysis with the visceral adiposity score showed decreasing functional connectivity between both amygdalae and both posterior insulae. Other reduced connectivities with this score were observed between right amygdala and cingulate cortex, the right prefrontal medial cortex and both parietal precuneus, the left prefrontal medial cortex and right precuneus and superior parietal lobule, as well as increased connectivity between the posterior cingulus and right precuneus. Conclusion: These findings suggest that adolescent obesity, specially associated with higher visceral adiposity, is also related with altered brain functional connectivity, possibly related with self-control and reward mechanisms. / Introdu??o: A obesidade na inf?ncia e adolesc?ncia representa um problema de sa?de preocupante, sendo considerada uma epidemia global pela Organiza??o Mundial de Sa?de e um importante fator para obesidade na vida adulta. Os mecanismos neurocognitivos que levam ? obesidade ainda s?o pobremente compreendidos, no entanto, novos estudos baseados em Resson?ncia Magn?tica Funcional (RMF), incluindo pacientes adultos, t?m revelado conectividades alteradas comparando pacientes obesos e n?o obesos, os quais incluem mecanismos relacionados a recompensa e circuitos de autocontrole. N?o obstante, estas diferen?as n?o s?o consistentemente estudadas em adolescentes e crian?as obesas. Objetivo: Demonstrar poss?veis diferen?as de conectividade funcional entre adolescentes obesos e controles, avaliados com RMF em Estado de Repouso (RMFER). M?todo: Dados foram obtidos de 38 pacientes, com idade entre 15 e 18 anos, sendo 16 no grupo obeso e 22 no grupo controle. Os sujeitos foram submetidos a RMFER, e tamb?m RM abdominal para a quantifica??o de adiposidade visceral. Dados de ?ndice de Massas Corporal (IMC) foram coletados. Usando o software AFNI, mapas de escore Z de conectividade funcional foram obtidos de regi?es de interesse localizadas nas am?gdalas, c?rtex do c?ngulo posterior e c?rtex pr?-frontal bilateral. Estes mapas foram analisados usando testes t e an?lise de regress?o m?ltipla com os dados de IMC e de adiposidade visceral, considerando significativo um valor p de < 0,05, corrigido atrav?s do software clustsim. Resultados: An?lise de grupo n?o demonstrou diferen?as em rela??o ao IMC entre os grupos obeso e n?o obeso. A an?lise de regress?o m?ltipla tamb?m n?o demonstrou diferen?as com os dados de IMC. No entanto, an?lise de regress?o com o coeficiente de adiposidade visceral demonstrou redu??o da conectividade entre ambas am?gdalas e as ?nsulas posteriores. Outras conectividades reduzidas com este coeficiente foram observadas entre a am?gdala direita e c?rtex do c?ngulo, entre o c?rtex pr?-frontal medial direito e ambos prec?neos parietais, entre o c?rtex pr?-frontal medial esquerdo e o prec?neo direito e l?bulo parietal superior direito, bem como conectividade aumentada entre o c?ngulo posterior e o prec?neo direito. Conclus?o: Estes achados sugerem que a obesidade na adolesc?ncia, especificamente associada a maior adiposidade visceral, ? tamb?m relacionada a altera??es da conectividade funcional cerebral, possivelmente devido a mecanismos de autocontrole e recompensa.
4

Desenvolvimento de sondas nanoestruturadas de ?xido de ferro para imageamento biom?dico n?o invasivo

Oliveira, Elisa Magno Nunes de 28 February 2014 (has links)
Made available in DSpace on 2015-04-14T13:59:06Z (GMT). No. of bitstreams: 1 457483.pdf: 5023547 bytes, checksum: e9f63d304ec1410bd1e9d8f328ceaa18 (MD5) Previous issue date: 2014-02-28 / In this work we investigated the synthesis, characterization and contrast properties of core-shell nanoparticles of iron oxide coated with dextran and functionalized with amine groups. Fluorophores groups were incorporated on the nanoparticles surface, allowing their use as contrast agents for magnetic resonance imaging and optical microscopy. The nanoparticles synthesis was performed by the coprecipitation method of iron salts in basic medium, along with the polymer coating. The synthesis parameters were modified to investigate their influence on the size distribution of nanoparticles. Transmission electron microscopy observations and dynamic light scattering showed a magnetic iron oxide core with an average diameter around 10-15 nm and the total average hydrodynamic diameters between 16-50 nm, depending on the synthesis conditions. The FTIR spectra showed characteristics absorption bands pure dextran in the synthesized core-shell nanoparticles. The zeta potential analysis showed positive values close to zero and stability at neutral pH. The magnetization curves of the nanoparticles revealed superparamagnetic behavior, with the characteristic absence of hysteresis and no magnetization at zero field. The UV-vis and flow cytometry analysis revealed the presence of fluorescent groups in the nanoparticles and the feasibility of their use in optical imaging. Studies of relaxation times of the nuclear magnetization have shown the decrease of the magnetic resonance signal with increasing nanoparticles concentration, reducing the relaxation times T1 and T2 in the nanoparticle aqueous solutions. The relaxivities ratios (r2/r1) ranged between 5.06 and 51.0 and were within the value of iron oxide contrast agents commercially available. / Neste trabalho, pesquisou-se a s?ntese, a caracteriza??o e as propriedades de contraste por imagem de nanopart?culas core-shell de ?xido de ferro, revestidas com dextran e funcionalizadas com grupos amina. Grupos fluor?foros foram incorporados na superf?cie das nanopart?culas, possibilitando seu uso como agente de contraste para imageamento por resson?ncia magn?tica e por microscopia ?ptica. As s?nteses das nanopart?culas foram realizadas pelo m?todo de coprecipita??o de sais de ferro, com o pol?mero de revestimento. Par?metros da s?ntese foram modificados para averiguar sua influ?ncia na distribui??o de tamanho das nanopart?culas. Os resultados da morfologia e da distribui??o de tamanhos por TEM e DLS mostraram um n?cleo com di?metros m?dios entre 10-15 nm e di?metros hidrodin?micos m?dios entre 16-50 nm, dependendo do procedimento de s?ntese. Os espectros de FTIR apresentaram bandas de absor??o caracter?sticas das liga??es presentes no dextran puro e nas nanopart?culas sintetizadas. A an?lise do potencial zeta revelou valores positivos pr?ximos de zero e estabilidade em pH neutro As medidas de magnetiza??o revelaram comportamento superparamagn?tico pela aus?ncia de histerese na curva de magnetiza??o. As an?lises por UV-vis e por citometria de fluxo revelaram a presen?a dos grupos fluorescentes nas nanopart?culas e a viabilidade de seu uso em imagens ?pticas. Os estudos nos tempos de relaxa??o magn?tica nuclear mostraram efeitos de contraste, perturbando a intensidade de sinal com o aumento da concentra??o, diminuindo os tempos de relaxa??o T1 e T2 das solu??es aquosas de nanopart?culas. A rela??o entre as relaxividades (r2/r1) foi entre 5.06 e 51.0, dentro dos valores dos agentes de contrastes de ?xido de ferro comercialmente dispon?veis.
5

Confiabilidade em resson?ncia magn?tica funcional no estado de repouso em diferentes estrat?gias de pr?-processamento

Aurich, Nathassia Kadletz 22 August 2014 (has links)
Made available in DSpace on 2015-04-14T13:56:33Z (GMT). No. of bitstreams: 1 463003.pdf: 2663394 bytes, checksum: 0158a49caa9b116197cb1f3a76c44980 (MD5) Previous issue date: 2014-08-22 / Resting State functional Magnetic Resonance Imaging (rs-fMRI) provides information about the functional connectivity of brain areas. However, prior to calculating the functional connectivity of the brain, there is a choice of several preprocessing steps that need to be selected. A critical source of variation between studies arises from distinct preprocessing approaches prior to the functional connectivity analysis. Therefore, a study to examine the reliability of different methods for pre-processing data from rs-fMRI is necessary. In this study, seven preprocessing strategies were tested and the reliability was evaluated between them in Graph Theoretical (GT). The sample used in this study is from a public database and consists of control subjects. Measures of GT were calculated using different strategies, after applying a method of subdividing the brain into 190 regions of interest. The following measures were calculated: global efficiency, characteristic path length, clustering coefficient and local efficiency. The results indicate that there is a significant difference in measurements of GT depending on the preprocessing strategy selected. It was also found that noise estimation parameters are correlated with GT measures. Moreover, it is observed that the level of thresholding chosen in the connectivity matrix can affect the measurements of GT, therefore further studies regarding this topic are needed. It was concluded, based on the sample used in this work that the method of scrubbing by outliers could increase the reliability of measurements of GT and reduce dependence on the movement of the patient's head. / A Resson?ncia Magn?tica Funcional no estado de repouso (rs-fMRI, do ingl?s resting state functional Magnetic Resonance) permite obter informa??es a respeito das ?reas de conectividade funcional do c?rebro. Por?m, a visualiza??o dessa conectividade s? ? poss?vel ap?s aplicar uma s?rie de etapas de processamento de imagens antes que se possa avaliar a conectividade cerebral. Considerando a limita??o na quantifica??o dos dados de rs-fMRI, e sabendo que uma fonte de varia??o cr?tica para a compara??o entre os estudos ? o fato de cada um deles remover, incluir ou mudar par?metros nos passos de pr?-processamento de rs-fMRI, ? necess?rio um estudo para analisar a confiabilidade de diferentes metodologias de pr?processamento de dados de rs-fMRI. Para tanto, a Teoria dos Grafos (TG) foi utilizada como par?metro final para avaliar a conectividade. Neste presente trabalho, foram testadas sete estrat?gias de pr?-processamento e foi avaliada a confiabilidade entre elas quando s?o feitas medidas de TG. A amostra utilizada neste trabalho ? de uma base de dados p?blica e ? composta por indiv?duos controle. As medidas de TG foram calculadas nas diferentes estrat?gias, ap?s aplicar um m?todo de parcelamento do c?rebro em 190 regi?es. Foram calculadas as seguintes medidas: efici?ncia global, comprimento do caminho caracter?stico, coeficiente de agrupamento e efici?ncia local. Os resultados indicaram que existe uma diferen?a significativa nas medidas de teoria dos grafos quando o pr?-processamento ? feito de diferentes maneiras. Foi encontrado tamb?m que par?metros de estimativa de ru?do s?o correlacionados com as medidas de TG. Al?m disso, observa-se que o n?vel de limiariza??o escolhido na matriz de conectividade pode afetar significativamente as medidas de TG, sendo necess?rio um estudo mais aprofundado a respeito deste tema. Concluiu-se, baseado na amostra utilizada neste trabalho, que o m?todo de scrubbing por outliers pode aumentar a confiabilidade das medidas de TG e reduzir a sua depend?ncia com o movimento da cabe?a do paciente.
6

Sistema para est?mulo olfativo em estudos de neuroimagem

Fachel, Fl?via Nathiely Silveira 15 January 2015 (has links)
Made available in DSpace on 2015-04-14T13:56:34Z (GMT). No. of bitstreams: 1 464986.pdf: 769829 bytes, checksum: 49435c45502b8b8d745ac315c7c4ac12 (MD5) Previous issue date: 2015-01-15 / In the last three decades, neuroimaging studies have provided significant advances in knowledge of the human brain, especially of brain areas hitherto little explored, such as olfaction. Many factors have been reported as able to alter the olfactory threshold and, more recently, the clinical relevance related to changes in this threshold has been largely addressed, principally in relation to neurodegenerative diseases. In parallel, many industries have sought innovative tools for assessing the impact of aromas in the population. Given the lack of adequate national tools for these applications, the present research aimed to develop a robust, automated and instrumented method for olfactory stimuli in neuroimaging studies, with a man-machine interface able to control and visualize the function in a user-friendly way. The results showed that the system was instrumented in a manner compatible with the functional magnetic resonance imaging environment. Furthermore, it nebulized the aromatic sample homogeneously and presented a similar velocity and flow of the air in the three valves. Therefore, this instrument will be able to help identify the mechanisms involved in olfactory threshold change in different situations and may provide important clinical advances. Additionally, it can be an auxiliary tool in business marketing strategies. / Os estudos de neuroimagem, nas ?ltimas tr?s d?cadas, proporcionaram avan?os significativos no conhecimento do c?rebro humano, especialmente, de ?reas cerebrais at? ent?o pouco exploradas, como, o olfato. Muitos fatores t?m sido referidos como capazes de alterar o limiar olfativo, e nos ?ltimos tempos, a relev?ncia cl?nica relacionada ?s altera??es nesse limiar tem sido bastante abordada, principalmente, em rela??o a doen?as neurodegenerativas. Em paralelo, muitas ind?strias t?m buscado instrumentos inovadores para avaliar o impacto dos aromas na popula??o. Dada a car?ncia de ferramentas nacionais adequadas para essas aplica??es, o presente trabalho desenvolveu um sistema para est?mulo olfativo robusto, instrumentado e automatizado para estudos de neuroimagens, com uma interface homem-m?quina capaz de controlar e visualizar o funcionamento de forma amig?vel. Os resultados obtidos demonstraram que o sistema desenvolvido foi instrumentado de forma compat?vel com o ambiente de Resson?ncia Magn?tica funcional. Al?m disso, nebulizou a amostra arom?tica de forma homog?nea. Dessa forma, esse instrumento ser? capaz de auxiliar na identifica??o dos mecanismos envolvidos na altera??o do limiar olfativo em diferentes situa??es, podendo proporcionar avan?os cl?nicos importantes; al?m, de poder ser uma ferramenta auxiliar em estrat?gias de marketing empresarial.
7

S?ntese do PET-CO-PLLA e avalia??o da biodegrada??o em solo preparado

Melo, Fernanda Colpo de 24 March 2009 (has links)
Made available in DSpace on 2015-04-14T13:58:31Z (GMT). No. of bitstreams: 1 413402.pdf: 2458200 bytes, checksum: ce9298755d819e0d071877d9d5b86560 (MD5) Previous issue date: 2009-03-24 / Este trabalho apresenta um estudo sobre a reciclagem qu?mica do poli(tereftalato de etileno) (PET) p?s-consumo atrav?s da s?ntese de novos copoli?steres alif?ticoarom?ticos obtidos a partir da polimeriza??o em massa, em altas temperatura (240 ?C), do poli(?cido L-l?ctico) com o PET p?s-consumo em diferentes propor??es em massa. Ap?s a s?ntese e caracteriza??o dos copol?meros realizou-se o processo de degrada??o em solo preparado pelas normas da ASTM G160 International. Atrav?s dos espectros de RMN 1H e FTIR foi poss?vel confirmar a forma??o dos copol?meros. Tamb?m, foi evidenciado pelos dados de DSC, TGA e MEV que os copol?meros que possuem menor teor de PET degradam com mais facilidade e possuem menor estabilidade t?rmica. Contudo, podemos observar que esta reciclagem qu?mica do PET ? um m?todo importante para ajudar na resolu??o do impacto ambiental gerado pelo ac?mulo deste material, que possui boas propriedades mec?nicas, alta resist?ncia qu?mica aliada ? alta produ??o.
8

S?ntese e caracteriza??o de nanoestruturas magn?ticas como agente de contraste em imagens biom?dicas

Lima, Francisco Ant?nio Paquete 24 August 2012 (has links)
Made available in DSpace on 2015-04-14T13:58:54Z (GMT). No. of bitstreams: 1 442327.pdf: 1822421 bytes, checksum: 8245c1989efe77ad16c8f717de01179d (MD5) Previous issue date: 2012-08-24 / In this study we investigated the synthesis and characterization (morphological structural and magnetic) of iron oxide nanoparticles coated with dextran and functionalized with amino groups, which are useful as contrast agents for magnetic resonance imaging. For the synthesis we used the method of co-precipitation of Fe (III) and Fe (II) with ammonium hydroxide. Three batches of samples were synthesized under identical conditions. The analysis of samples from each batch revealed some differences in the stability against agglomeration and iron concentrations (ranging from 10 to 8 mg / mL). A narrow size distribution of the nanoparticles was observed by DLS (Dynamic Light Scattering) in all cases with a mean hydrodynamic diameter of about 10 nm. The mean particle size was confirmed by TEM (Transmission Electron Microscopy), images. Elemental analysis by Rutherford Backscattering Spectrometry (RBS) and Energy Dispersive Spectroscopy (EDS) revealed a structure compatible with iron oxide, and a thermal decomposition pattern dominated by the polymer coating of the particles. The magnetic properties of the particles were confirmed by Alternating Gradient Force Magnetometer (AGFM) whit reveals a vanishing hysteresis loop. Measurements of the magnetic nuclear relaxivity were performed directly in a magnetic resonance imaging (MRI) equipment Whit an MRI phantom containing samples with different concentrations of the FeNP. The study of magnetic relaxation with test objects indicated a clear effect of the FeNP or the MRI signal through the decreases and T1 and T2 in aqueous solutions. Measured relaxivities obtaining from the curves of the relaxation rate versus FeNP concentration were between 41 and 24 mM-1s-1 for r2 and 2,0 to 1,7 mM-1s-1 for r1. We conclude that the method applied in the synthesis of the FeNP was be very efficient in producing NPs with suitable properties for use as a contrast agent in MRI images / Nesse trabalho investigou-se a s?ntese e caracteriza??o morfol?gica, estrutural e magn?tica de nanopart?culas de ?xido de ferro, recobertas com dextran e funcionalizadas com grupos amina, ?teis como uma plataforma de agentes de contraste para imageamento por resson?ncia magn?tica. Para a s?ntese, foi usado o m?todo de coprecipitac?o do Fe (III) e Fe (II) com hidr?xido de am?nio. Foram sintetizados tr?s lotes de amostras. A an?lise de amostras de cada um dos lotes revelou algumas diferen?as quanto ? estabilidade frente a aglomera??o e a concentra??o de ferro (variando de 8 -10 mg/mL). Foi observado por Espalhamento de Luz Din?mico uma distribui??o estreita de tamanho das nanopart?culas em todos os casos, com um di?metro hidrodin?mico m?dio em torno de 5-8 nm, confirmados pelas imagens de TEM (Microscopia Eletr?nica de Transmiss?o). Atrav?s de an?lise de Espectroscopia de Energia Dispersiva (EDS) e Retroespalhamento Rutherford (RBS) obtivemos uma distribui??o elementar compat?vel com a do ?xido de ferro, e padr?o de decomposi??o t?rmico dominado pelo recobrimento polim?rico demonstrado nas curvas do an?lise termogravim?trica (TGA). Curvas de magnetiza??o obtidas por um Magnet?metro de Gradiente de for?a Alternada (AGFM) confirmaram a caracter?stica magn?tica das part?culas e aus?ncia de histerese. Medidas de relaxividade magn?tica nuclear foram feitas diretamente num equipamento de imagens por resson?ncia magn?tica (MRI) atrav?s de um phantom contendo amostras com diferentes concentra??es das nanopart?culas de ?xido de ferro (FeNP). O estudo da relaxa??o magn?tica em objetos teste indicou um efeito claro de perturba??o do sinal pelas part?culas, com diminui??es do tempo de relaxa??o longitudinal (T1) e do tempo de relaxa??o transversal (T2) em solu??es aquosas, confirmando a obten??o do efeito de contraste desejado, com relaxividades que variaram entre 41 e 24 mM-1s-1 para relaxividade (r2) e 2,0 a 1,7 mM-1s-1 para a relaxividade (r1). Conclu?mos que, o m?todo qu?mico por coprecipita??o de Fe(II) e Fe(III) utilizado na s?ntese de nanopart?culas magn?ticas mostrou-se apropriado para produzir nanopart?culas (NPs) com propriedades adequadas para uso como agente de contraste em imagens por MRI
9

Escore de Williams aplicado na resson?ncia magn?tica para avalia??o hep?tica de crian?as com fibrose c?stica

Baldissera, Marilisa 03 March 2017 (has links)
Submitted by PPG Pediatria e Sa?de da Crian?a (pediatria-pg@pucrs.br) on 2018-01-02T16:51:55Z No. of bitstreams: 1 Disserta??o Mestrado Marilisa.pdf: 905969 bytes, checksum: 348718dad9108301470f73e80e214e5c (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-01-24T12:31:32Z (GMT) No. of bitstreams: 1 Disserta??o Mestrado Marilisa.pdf: 905969 bytes, checksum: 348718dad9108301470f73e80e214e5c (MD5) / Made available in DSpace on 2018-01-24T12:33:57Z (GMT). No. of bitstreams: 1 Disserta??o Mestrado Marilisa.pdf: 905969 bytes, checksum: 348718dad9108301470f73e80e214e5c (MD5) Previous issue date: 2017-03-03 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Cystic fibrosis (CF) has long been described as a fatal genetic disease. Currently, improvement in the care of these patients contributes to longer survival and thereby allows the observation of other symptoms related to mutations of the cystic fibrosis transmembrane chloride regulator (CFTR) gene, responsible for the disease. Although pulmonary disease continues to be the leading cause of morbidity and mortality, CF also requires that attention be given to manifestations of the disease in other organs, such as liver disease. CF-associated liver disease (CFLD) can be considered an independent risk factor for mortality and lung transplantation. The major challenge is to diagnose CFLD, because the changes may remain asymptomatic until advanced stages of the disease. There is currently no single test that is sensitive and specific enough to assess liver function, and early diagnosis of CFLD requires a combination of regular clinical examination, biochemical tests, and imaging studies. There are high expectations for noninvasive tests that are harmless to patients and can be easily repeated and compared in order to detect changes as early as possible. Imaging techniques have improved significantly over the past decade and new technologies are being incorporated into clinical practice. Ultrasonography (US), computed tomography and magnetic resonance imaging (MRI) are the main imaging modalities currently used for examination, but new MRI-based techniques have acquired great importance. Thus, it would be desirable to develop a more accurate method than US, which is the most widely used routine examination, as well as the ultrasound scoring system described by Williams et al in 1995 and used so far. This study aimed to describe possible MRI abnormalities in children with CF and correlate them with US findings, particularly in relation to parameters of parenchyma, border, and liver fibrosis. Methods: Patients with a diagnosis of CF underwent clinical examination, anthropometric measurements, US, and MRI. MRI was performed without sedation or contrast. The liver was evaluated using the scoring system described by Williams et al on US and MRI images. Other MRI features were also analyzed, including degenerative nodules, atrophy of the right hepatic lobe, and posterior notch sign of the hepatic lobe. Results: The US and MRI findings of 20 patients were analyzed. Patient age ranged from 8 to 19 years. Five patients showed US abnormalities with an ultrasound score greater than 3, 4 patients with a score of 7, and 1 patient with a score of 9. When the Williams scoring criteria were applied to MRI, 5 patients were evaluated as having a score of 9. US did not assess liver fibrosis in the same way as MRI. In the US evaluation, 4 patients received a score of 1 for this parameter, while in the MRI evaluation all patients received the maximum score. MRI revealed 4 patients with atrophy of the right hepatic lobe, 3 patients with degenerative nodules, and 2 patients with esophageal varices. Four patients (80%) showed the posterior notch sign of the hepatic lobe. Conclusion: Although there was a good correlation between US and MRI, MRI performed better than US in the assessment of liver fibrosis. The Williams scoring system can also be applied to hepatic MRI. Thus, MRI stands out as a noninvasive method that can provide further information related to CFLD, contributing to the overall assessment of patients with CF. / A fibrose c?stica (FC) foi por muito tempo descrita como uma doen?a gen?tica fatal. Atualmente, a melhora nos cuidados de sa?de destes pacientes possibilitou uma maior sobrevida e assim a observa??o de outras sintomatologias relacionadas ? muta??o do gene CFTR (cystic fibrosis transmembrane chloride regulator), respons?vel pela doen?a. Apesar da doen?a pulmonar continuar sendo a principal causa de morbidade e mortalidade, a FC exige aten??o tamb?m para manifesta??es de doen?a em outros ?rg?os, como o caso da doen?a hep?tica. A doen?a hep?tica associada ? FC (DHFC) pode ser considerada um fator de risco independente para a mortalidade e transplante pulmonar. O grande desafio ? o seu diagn?stico, pois suas altera??es podem permanecer assintom?ticas at? est?gios avan?ados da doen?a. N?o h? dispon?vel um teste que seja sens?vel e espec?fico para avaliar a fun??o hep?tica, o diagn?stico precoce da DHFC requer o conjunto de exame cl?nico regular, exames de bioqu?mica e de imagem. ? grande a expectativa por exames n?o invasivos que sejam in?cuos para o paciente e possam ser facilmente repetidos e comparados para a busca de altera??es o mais precoce poss?vel. As t?cnicas de imagem t?m melhorado significativamente na ?ltima d?cada e as novas tecnologias est?o come?ando a entrar na pr?tica cl?nica. Ultrassonografia (US), tomografia computadorizada e resson?ncia magn?tica (RM) s?o as principais modalidades usadas atualmente, mas novas t?cnicas baseadas em RM est?o em destaque. Desta forma, seria desej?vel desenvolver uma metodologia mais acurada que a US que ? o exame rotineiramente mais difundido, assim como o escore ultrassonogr?fico descrito por Williams et al em 1995, utilizado at? ent?o. Nosso objetivo ? descrever as poss?veis altera??es encontradas na RM em crian?as com FC e correlacionar com os achados da US, principalmente em rela??o aos par?metros de par?nquima, borda e fibrose hep?tica. M?todos: Pacientes com diagn?stico de fibrose c?stica realizaram avalia??o cl?nica, antropom?trica, exames de ultrassonografia e resson?ncia magn?tica. Os exames de resson?ncia magn?tica foram realizados sem seda??o e sem contraste. O f?gado foi avaliado segundo o escore descrito por Williams et al na ultrassonografia e na resson?ncia magn?tica. Foram analisados ainda outros diferentes aspectos na RM entre eles: n?dulos degenerativos, atrofia do lobo hep?tico direito, o sinal do entalhe posterior do lobo hep?tico. Resultados: Os exames de vinte pacientes foram analisadas, os participantes do estudo tinham idade entre 8 e 19 anos. Cinco pacientes apresentaram exame de US alterado com escore ultrassonogr?fico maior que 3, quatro pacientes com escore 7 e um com escore 9. Ao aplicar os crit?rios do escore de Williams na resson?ncia magn?tica, os 5 pacientes foram avaliados com escore 9. A ultrassonografia n?o pode avaliar a fibrose hep?tica da mesma forma que a resson?ncia, na US quatro pacientes receberam pontua??o 1 para o par?metro, j? na RM todos receberam pontua??o m?xima. Na RM, foram identificados quatro pacientes com atrofia do lobo hep?tico direito, tr?s pacientes com n?dulos degenerativos e 2 pacientes com varizes esof?gicas. Quatro pacientes (80%) apresentaram o sinal do entalhe posterior do lobo hep?tico direito. Conclus?o: Existe uma boa correla??o entre US e RM, por?m a RM teve melhor desempenho na avalia??o da fibrose hep?tica. O escore de Williams tamb?m pode ser aplicado para an?lise hep?tica pela RM. Assim a RM se destaca como um m?todo n?o invasivo que nos fornecer ainda outras informa??es relacionadas com a DHFC que contribuem na avali??o global do paciente com FC.
10

Estudo da sequ?ncia de difus?o atrav?s da resson?ncia magn?tica de 3 Tesla em pacientes com doen?a de crohn

Durayski, Evandra 07 March 2018 (has links)
Submitted by PPG Medicina e Ci?ncias da Sa?de (medicina-pg@pucrs.br) on 2018-06-12T14:01:32Z No. of bitstreams: 1 EVANDRA_DURAYSKI.pdf: 1831041 bytes, checksum: 14177d40991ac101fe309c07dd96d0a7 (MD5) / Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2018-06-22T18:42:06Z (GMT) No. of bitstreams: 1 EVANDRA_DURAYSKI.pdf: 1831041 bytes, checksum: 14177d40991ac101fe309c07dd96d0a7 (MD5) / Made available in DSpace on 2018-06-22T18:51:12Z (GMT). No. of bitstreams: 1 EVANDRA_DURAYSKI.pdf: 1831041 bytes, checksum: 14177d40991ac101fe309c07dd96d0a7 (MD5) Previous issue date: 2018-03-07 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Introduction: Crohn's disease (CD) is an idiopathic inflammatory bowel disease, which mainly affects the terminal ileum A biopsy colonoscopy with regard to the gold standard in the assessment of disease and the area of education costly and with anesthetic risks. Noninvasive methods of evaluation such as magnetic resonance enterography (MRE) have been developed in the last decade. Evaluation systems such as the magnetic resonance index of activity (MaRIA) and Clermont score are used in clinical studies to quantify inflammation in patients with CD. A diffusion-weighted magnetic resonance imaging (DWI) evaluates a restitution of the water molecules in the tissues. Studies have shown a correlation between a restriction of diffusion on the wall of the intestine with inflammation. However, few studies with MRE of 3 Tesla support analysis a apparent diffusion coefficient (ADC) correlactionan in inflammatory proces in the terminal ileum. Purpose: To determine the applicability of the sequence DWI in 3 Tesla MRE in the identification of inflammatory signs in the distal ileum in patients with Crohn?s disease. Materials and Methods: We retrospectively studied 38 individuals with CD, who underwent MRE between March 2014 to september 2017 and had an anatomopathological and endoscopic evaluation in the distal ileum. The following variables were evaluated: diffusion (DWI), quantitative ADC, wall thickening, intramural edema, ulcerations, stricture, segmental mural hyperenhancement, relativo contrast enchancement (RCE), MaRIA and Clermont score. Results: The mean duration of the disease was 7 ? 5 years, 19 patients (50%) were male. Eighteen patients (47%) had active inflammatory disease and twenthy (53%) had disease in remission in the terminal ileum. Patients with active inflammatory disease in the distal ileum had a greater restriction on DWI, intramural edema, wall thickening, MaRIA and Clermont score, when compared to the group of patients without inflammation. The correlation between MaRIA and Clermont score (r = 0.975) was strong. The Kappa coefficient of interobserver agreement was excellent for the MaRIA, Clermont score and restriction DWI, moderate for ADC and weak for RCE. The best cut-off point in this study for the inflammation identified by the colonoscopy for the ADC was 2.1x103mm2/s, with sensitivity of 88.8% and specificity of 95.0%. The DWI presented accuracy of 89.4%, sensitivity of 88.9% and specificity of 90.0% in relation to inflammation identified by colonoscopy. Conclusion: The quantitative values of ADC have a good sensitivity in detecting inflammation at colonoscopy. Analysis of the diffusion sequence of good accuracy in the detection of ileum inflammmation in patients with Crohn's disease. However, when in association with intramural enhancement, edema and wall thickening it has a strong correlation with severe inflammation identified at colonoscopy. / Introdu??o: A Doen?a de Crohn (DC) ? uma doen?a inflamat?ria intestinal idiop?tica, que acomete principalmente o ?leo terminal. A colonoscopia seguida de bi?psia, apesar de ser considerada o padr?o-ouro na avalia??o de doen?a ativa, ? uma ferramenta de monitoramento onerosa e com riscos anest?sicos. M?todos de avalia??o n?o invasivos, como a enterorresson?ncia (Entero-RM), foram desenvolvidos na ?ltima d?cada. Os sistema de pontua??o como o ?ndice MaRIA e escore de Clermont s?o utilizados em estudos cl?nicos para quantificar a inflama??o em pacientes com DC. A difus?o ? uma sequ?ncia da resson?ncia que avalia a restri??o das m?leculas de ?gua nos tecidos. Estudos demonstraram correla??o entre a restri??o da difus?o na parede do intestino com a inflama??o. Entretanto, poucos estudos com a Entero-RM de 3 Tesla avaliaram se a an?lise quantitativa do ADC (coeficiente de difus?o aparente) teria sensibilidade na avalia??o de processo inflamat?rio no ?leo terminal. Objetivos: Determinar a aplicabilidade da sequ?ncia de Difus?o na Entero-RM de 3 Tesla na identifica??o de sinais inflamat?rios no ?leo distal em pacientes com DC. Materiais e M?todos: Foram estudados retrospectivamente 38 indiv?duos com DC, submetidos a entero-RM no per?odo mar?o de 2014 a setembro de 2017 e que tinham avalia??o anatomopatol?gica e endosc?pica no ?leo distal. Foram avaliadas a seguintes vari?veis: difus?o, ADC quantitativo, espessamento parietal, edema, ulcera??es, estreitamento, realce pelo contraste, realce relativo ao contraste (RCE), ?ndice MaRIA e escore de Clermont. Resultados: A m?dia da dura??o da doen?a foi de 7 ? 5 anos, 19 pacientes (50%) eram do sexo masculino. Dezoito pacientes (47%) tinham doen?a inflamat?ria ativa e 20 (53%) tinham doen?a em remiss?o no ?leo terminal. Os pacientes que apresentavam doen?a inflamat?ria ativa no ?leo distal tiveram maior restri??o a difus?o, edema na mucosa, espessamento parietal, ?ndice de MaRIA e maior valor no escore de Clermont, quando comparados com o grupo de pacientes sem inflama??o. Foi forte a correla??o entre o ?ndice MaRIA com o escore de Clermont (r=0,975). O Coeficiente Kappa de concord?ncia interobservador foi excelente para ?ndice MaRIA, escore de Clermont e restri??o a difus?o, moderada para ADC e fraca para o RCE. O melhor ponto de corte neste estudo para a inflama??o identificada pela colonoscopia para o ADC foi de 2,1x10-3mm2/s, com sensibilidade de 88,8% e especificidade de 95,0%. A sequ?ncia da difus?o apresentou acur?cia de 89,4%, sensibilidade de 88,9% e especificidade de 90,0% em rela??o a inflama??o identificada pela colonoscopia. Conclus?o: Os valores quantitativos do ADC t?m uma boa sensibilidade na detec??o de inflama??o na colonoscopia. A an?lise da sequ?ncia da difus?o tem boa acur?cia na detec??o de segmentos intestinais ileais inflamados em pacientes com doen?a de Crohn. Em suma, quando a restri??o a difus?o tem associa??o com realce, edema e espessura da parede, aumenta a correla??o com a inflama??o severa identificada na colonoscopia.

Page generated in 0.0385 seconds