• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 706
  • 29
  • 9
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 756
  • 461
  • 128
  • 90
  • 86
  • 84
  • 77
  • 77
  • 75
  • 67
  • 61
  • 59
  • 56
  • 54
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Um controlador H 'infinito' alfa de Banda limitada para o controle ativo de vibração estrutural / A band limited H 'INFINITE¿ controller for the active control of structural vibration

Moreira, Fernando Jose de Oliveira 08 October 1998 (has links)
Orientador: Jose Roberto de França Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-24T09:38:32Z (GMT). No. of bitstreams: 1 Moreira_FernandoJosedeOliveira_D.pdf: 15667292 bytes, checksum: b9be95fa70780c1440ed7671ea43a6dd (MD5) Previous issue date: 1998 / Resumo: Neste trabalho é apresentada uma metodologia para controle ativo de vibração. O objetivo é amortecer modos de vibração de uma estrutura na região de média freqüência. A técnica empregada envolve controle por realimentação e se aplica tanto a problemas de controle de estruturas flexíveis como controle ativo de vibração e ruído. O enfoque proposto é o de controle robusto utilizando a teoria 'H IND. INFINITO¿. Desta forma, inserem-se no projeto características de robustez à dinâmica não modelada devido ao truncamento do modelo do sistema estrutural. Também estão presentes no projeto critérios de robustez à variação nos parâmetros da dinâmica do sistema. O resultado é um controlador de baixa ordem de fácil implementação que produz um eficiente amortecimento nos modos a serem controlados, sem alterar a dinâmica dos demais modos da estrutura. Dois exemplos experimentais são apresentados, comprovando a exeqüibilidade do projeto / Abstract: This work presents a new approach for the active control of structural vibration. The main goal is to damp some of the structural modes in the mid-frequency range. The feedback control strategy used in this work can be applied either to the control of flexible structures or to the control of vibration and noise. It consists of an 'H IND. INFINITE¿ controller which is robust to unmodeled residual uncertainty due to model truncation of the structural system. AIso, a parametric robustness requirement, due to parameter variations of the system dynamics, is included in the designo Only the damping of the modes to be controlled is modified, while the other ones are kept unchanged. Two experimental examples are shown to demonstrate that the practical implementation of the proposed controller is feasible / Doutorado / Mecanica dos Sólidos e Projeto Mecanico / Doutor em Engenharia Mecânica
232

Investigação de ruido e sensibilidade em MAGFETs e avaliação do seu emprego no controle de emissão eletromagnetica em circuitos integrados de potencia / Investigation of noise and sensintivity in MAGFETs and its aplicationin the control of electromagnetic emissions in power integrated circuits

Castaldo, Fernando Cardoso 06 March 2005 (has links)
Orientador: Carlos Alberto dos Reis Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T14:40:24Z (GMT). No. of bitstreams: 1 Castaldo_FernandoCardoso_D.pdf: 30688674 bytes, checksum: 38148b8964d0d87ceacc943afb795fbc (MD5) Previous issue date: 2005 / Resumo: Este trabalho aborda a questão da compatibilidade eletromagnética em circuitos chaveados integrados, tipicamente conversores DC-DC dedicados. Neste sentido, propõe-se uma técnica de controle da emissão eletromagnética baseada no sensoriamento do campo magnético próximo através da utilização de transistores MOS do tipo split-drain. Desta forma, pode-se integrar conjuntamente o transistor de potência e o split-drain. O sinal produzido pelo sensor pode ser enviado a um circuito de acionamento que controla a derivada da corrente no transistor de potência, limitando, desta forma, a emissão gerada. Entretanto, o ruído associado ao transistor split-drain limita severamente a resolução do sensor. Estudos realizados indicaram a existência de uma corrente de ruído em excesso observada através de medidas de correlação de ruído, denominada corrente de ruído transversal. Esta corrente limita a relação sinal-ruído do sensor magnético, principalmente no modo diferencial, com impacto direto na resolução do sistema detector. A partir do entendimento dos mecanismos de geração de ruído investigados, circuitos detectores de campo magnético que atendam determinada resolução podem ser projetados, viabilizando-se assim, a implementação de sensores de emissão eletromagnética / Abstract: This work deals with the electromagnetic compatibility (EMI) issues aimed to power integrated circuits, typically DC-DC converters. An EMI controlling approach based on magnetic near field measurements using CMOS split-drain transistors (MAGFETS) as magnetic sensors is investigated. Monolithic applications can be envisaged comprising the power circuit and the magnetic sensor. The detected signal can be sent to a slew-rate-based controlling driver that sets the electromagnetic emissions below a specific leveI. However, the electronic noise associated with the split-drain transistor affects the sensor resolution. In this sense, it was observed through correlation measurements an excess noise current associated with the split-drain transistor, called transversal noise current. A noise model taking into account the transversal noise current is proposed, allowing the implementation of magnetic sensors featuring a specific resolution aimed to electromagnetic emissions detectors / Doutorado / Eletrônica, Microeletrônica e Optoeletrônica / Doutor em Engenharia Elétrica
233

Adaptação transcultural de um instrumento de avaliação do handicap auditivo para portadores de Perda Auditiva Induzida pelo Ruído Ocupacional

Tenório Gonçalves Holanda, Wanessa 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:13:35Z (GMT). No. of bitstreams: 2 arquivo4149_1.pdf: 789381 bytes, checksum: fab81cb7db18175a0d30cd38c10012a9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A Perda Auditiva Induzida pelo Ruído Ocupacional (PAIRO) é definida como uma doença crônica e irreversível resultante da exposição sistemática e prolongada a elevados níveis de ruído no ambiente de trabalho. Mesmo no estágio inicial, essa perda auditiva pode ser sentida e interferir na comunicação oral de seu portador, comprometendo em vários graus a qualidade de vida do mesmo. Não existe disponível, para a língua portuguesa, um instrumento específico de avaliação das implicações psicossociais da PAIRO e, por isso, o objetivo deste trabalho foi realizar a adaptação transcultural de um instrumento de avaliação do handicap auditivo da sua língua original (inglês) para o português e avaliar a sua confiabilidade e validade a partir da aplicação do mesmo numa população de 43 trabalhadores com PAIRO. Após a seleção do instrumento a partir de pesquisas nas bases de dados nacionais e internacionais, o questionário selecionado (Hearing Disability and Handicap Scale) passou por um processo de equivalência semântica que envolveu as etapas de tradução, retradução, apreciação formal da equivalência, pré-teste e crítica final por uma equipe multiprofissional para a elaboração de uma versão final para uso corrente no Brasil. O instrumento foi considerado de fácil compreensão e aplicação por parte dos trabalhadores e obteve medidas psicométricas consideradas, em geral, aceitáveis, considerando o tamanho reduzido da amostra e o fato de a população de estudo não possuir perdas auditivas muito significativas. Porém, a Escala de Inabilidades e Handicap Auditivo precisa ser testada em amostras maiores e representativas da população de trabalhadores brasileiros portadores de PAIRO a fim de ser ratificada a sua utilidade para a avaliação do handicap auditivo nessa população
234

Cancelador de eco para transmissão de voz via satelite : proposta de uma implementação

Matos, Carlos Jose de Campos 06 December 1991 (has links)
Orientador: João Marcos T. Romano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-17T11:46:13Z (GMT). No. of bitstreams: 1 Matos_CarlosJosedeCampos_M.pdf: 4047954 bytes, checksum: dbcb077c070a04d841327ae86ff984e1 (MD5) Previous issue date: 1991 / Resumo: Não informado / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
235

Inteligibilidade de fala em trabalhadores expostos a ruído com protetores auditivos / Speech intelligibility in workers exposed to noise with hearing protectors

Clayton Henrique Rocha 12 May 2017 (has links)
Introdução: O ruído é um dos principais agentes de poluição ambiental, que em intensidades elevadas, poderá causar a perda auditiva induzida por níveis de pressão sonora elevadas (PAINPSE). A PAINPSE é o segundo tipo de perda auditiva neurossensorial mais frequente, e considerada uma das principais doenças ocupacionais. Para evitar os prejuízos da exposição ao ruído ocupacional, legislações determinam o monitoramento e o desenvolvimento de ações para reduzir os efeitos da exposição, sendo o uso de dispositivos de proteção auditiva (DPA) a mais empregada. Contudo é comum que o trabalhador relate dificuldades para se comunicar com o DPA, o que pode induzi-lo ao uso inadequado. Os estudos já realizados apresentam discordâncias sobre os efeitos do DPA para a inteligibilidade da fala, além de serem poucos os que compararam participantes com perdas auditivas com normo-ouvintes. Objetivos: Avaliar a inteligibilidade de fala em trabalhadores expostos a ruído durante o uso de DPA. Métodos: Trata-se de um estudo transversal, aprovado pelo Comitê de Ética em Pesquisa da instituição nº 130/14, com amostra de 36 participantes, todos do sexo masculino e expostos ao ruído. Foram divididos em grupo normo-ouvintes (G1), com 20 participantes e com perda auditiva (G2), com 16 participantes. Todos os participantes realizaram avaliação da inteligibilidade de fala em campo acústico, utilizando listas de monossílabas e sentenças, em situações de uso do DPA no silêncio e no ruído e sem o uso do DPA no ruído. Resultados: Na avaliação da inteligibilidade de fala com DPA utilizando as monossílabas, ambos os grupos apresentaram porcentagens de acertos superiores à 95% na situação de silêncio. Na presença do ruído com o DPA, não foi detectado efeito de interação envolvendo grupo (p>=0,106) e nem efeito de grupo (p=0,182), mas houve efeito de interação entre intensidade de fala e relação sinal/ruído (S/R) (p=0,006). Na avaliação da inteligibilidade de fala no ruído sem o DPA, foi detectado efeito de interação entre uso do DPA e relação S/R (p=0,010) sobre a média das porcentagens de acertos. Na avaliação com listas de sentenças, a porcentagem de acertos com DPA foram superiores a 98% no silêncio; contudo, no ruído houve piora, com efeito de interação entre intensidade de fala e relação S/R (p=0,010) e entre grupo e relação S/R (p=0,039). Na comparação do uso/não uso do DPA, houve efeito de interação entre uso do DPA e as relações S/R (p=0,009) sobre a média das porcentagens de acertos. Conclusões: Para ambos os grupos, houve piora da inteligibilidade de fala com o aumento da intensidade do ruído; contudo, a dificuldade foi maior para o G2. Na comparação das situações com/sem o uso do DPA, o uso dificultou a inteligibilidade de fala, mas não houve diferença significante entre as situações. Por fim, ressalta-se a importância de realizar mais estudos dos efeitos do DPA na comunicação, além de inserir nas avaliações ocupacionais testes que avaliam a fala no ruído, para determinar as dificuldades que podem surgir no ambiente ocupacional, e assim desenvolver medidas que beneficiem os trabalhadores que necessitam se comunicar durante as atividades laborais / Introduction: Noise is one of the main agents of environmental pollution, and at high intensities, it may provoke noise-induced hearing loss (NIHL). NIHL is the second most frequent type of sensorineural hearing loss and it is considered one of the main occupational diseases. In order to avoid the effects of the exposition to occupational noise, legislation determines the monitoring and development of actions to reduce the effects of such exposure and one of the most applied measure is the mandatory use of hearing protection devices (HPD). However, workers often report difficulties to communicate when using the HPD, what may induce them to use it improperly. Previous studies showed divergences between the effects of HPD on speech intelligibility; besides, few studies compared participants with hearing loss to those with normal hearing. Purpose: To assess speech intelligibility of workers exposed to noise during the use of HPD. Methods: This is a cross-sectional study, approved by the Institution\'s Ethics Committee (nº 130/14) and counted on a sample of 36 participants, all males and exposed to noise. They were distributed into a normal hearing group (G1), with 20 participants and hearing loss group (G2), with 16 participants. All participants were submitted to an assessment of speech intelligibility in free field, using monosyllable and sentence lists, when using the HPD in silence and noise situation, and also without the use of HPD in noise. Results: In the assessment of speech intelligibility with HPD using the monosyllables, both groups presented percentages of correct answers above 95%. In the presence of noise with HPD, there was no interaction effect involving group (p>=0.106) or group effect (p=0.182), but there was found an interaction effect between speech intensity and signal-to-noise ratio (SNR) (p=0.006). In the assessment of speech intelligibility in noise without HPD, an interaction effect between HPD use and SNR (p=0.010) was detected over the mean percentage of correct answers. In the evaluation with lists of sentences, the percentage of correct answers with HPD were superior to 98% in the silence; however, in noise, there was a decrease on the interaction effect between speech intensity and SNR (p = 0.010) and between group and SNR (p = 0.039). In the comparison with/without use of HPD, there was found an interaction effect between hearing protection use and SNR (p = 0.009) on the mean percentage of correct answers. Conclusions: For both groups, it was noticed that speech intelligibility decrease with the increasing of noise intensity; nevertheless, the difficulty was greater for the group with hearing loss. In the comparison of situations with and without the use of HPD, its use made speech intelligibility more challenging, but no significant difference between the situations was found. Finally, it is important to highlight the importance of further studies regarding the effects of HPD on communication and, besides, inserting speech-in-noise tests in occupational examination in order to determine the difficulties that may arise in the occupational environment and thus, develop measures that benefits the workers who need communicate during their labor activities
236

Uma contribuição aos sistemas de monitoramento de integridade estrutural baseados na impedância eletromecânica sob aplicações de baixa relação sinal-ruído /

Castro, Bruno Albuquerque de. January 2019 (has links)
Orientador: Fabricio Guimarães Baptista / Coorientador: Francesco Ciampa / Banca: André Luiz Andreoli / Banca: Paulo Roberto de Aguiar / Banca: Rosemar Batista da Silva / Banca: Breno Ortega Fernandez / Resumo: Os sistemas de monitoramento de estruturas aeroespaciais, civis e navais, também conhecidos como sistemas de SHM ("Structural Health Monitoring"), têm como objetivo a detecção de danos estruturais em estágio inicial e, desta forma, se garantir a segurança dos usuários e reduzir os custos com manutenção. Entre as várias técnicas existentes para a detecção de danos, a técnica da impedância eletromecânica (E/M) se destaca pela sua metodologia simples e por utilizar transdutores piezelétricos de baixo custo. Basicamente, o diagnóstico de falhas estruturais se dá pela extração da impedância elétrica de um transdutor acoplado em uma estrutura hospedeira, e o diagnóstico estrutural é realizado pela aplicação de índices estatísticos como o desvio da raiz média quadrática - root mean square deviation (RMSD) - que é baseado na norma Euclidiana e o desvio do coeficiente de correlação - correlation coefficient deviation metric (CCDM) - baseado no coeficiente de correlação. Apesar de ser uma técnica promissora e eficaz, as pesquisas envolvendo a técnica da impedância eletromecânica são realizadas em laboratórios sob condições ideais. Todavia, na prática, durante a medição de impedância, é inevitável a contaminação dos sinais por ruído, o que pode influenciar e prejudicar significativamente o diagnóstico de danos estruturais, limitando a aplicabilidade da técnica E/M. Tomando como base essa questão, o objetivo deste trabalho é explorar novas técnicas de processamento de sinais oriundos das... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Structural Health Monitoring (SHM) systems aim to avoid and detect structural damages at the initial stage in order to promote human safety and reduction of maintenance costs. Among numerous SHM methods for damage detection, the electromechanical impedance (EMI) technique stands out to be a simple methodology that uses low-cost piezoelectric transducers. Basically, the structural damage diagnosis is achieved by extracting the electrical impedance of a transducer attached to a host structure and the failure quantification is accomplished by traditional statistical indices such as the root mean square deviation (RMSD) and the correlation coefficient deviation metric (CCDM). Although the EMI stands out to be an effective and promising SHM technique, research involving the electromechanical impedance is commonly performed in laboratories under ideal conditions. However, in practical applications, during the impedance measurements, it's inevitable the signal contamination by noise, which can significantly influence and impair the diagnosis of structural condition, limiting the applicability of the EMI. Based on this issue, the objective of this work is to explore new signal processing techniques from impedance measurements of piezoelectric transducers, aiming to expand the applicability of this promising SHM approach for low signal-to-noise ratio inspections conditions. Experimental tests were carried out on a carbon fiber reinforced plate and an aluminum component, which are wide... (Complete abstract click electronic access below) / Doutor
237

Presenteísmo e ruído ocupacional : estudo de associação /

Tavares, Renata da Silva Cardoso Rocha January 2019 (has links)
Orientador: Jorge Muniz Junior / Resumo: A produção e os fatores de risco que interferem na produtividade do trabalhador, vêm sendo discutido como um fator estratégico na administração das empresas. O presenteísmo visa analisar quais são os fatores de saúde que interferem na produtividade do trabalhador. O ruído ocupacional é uma realidade na qual os trabalhadores estão expostos diariamente e na qual há evidências científicas do efeito do ruído na saúde do funcionário. Este estudo tem como objetivo investigar a associação entre variáveis sociodemográficas e do trabalho com a ocorrência do presenteísmo e a relação com a exposição ao ruído ocupacional. Para tal estudo, a pesquisa caracterizara-se como exploratória, com abordagem quantitativa. No delineamento foi realizado um estudo de caso em uma indústria localizada no Vale do Paraíba, com uma amostra de 306 sujeitos. Os dados foram obtidos por meio da aplicação do protocolo WLQ de presenteísmo, do questionário de dados sociodemográficos e documentos a respeito do ruído fornecidos pela empresa. A análise de associação dos desfechos foi realizada por meio de regressão logística multivariada e com nível de significância de 5%. Pode-se verificar que, a demanda física foi a que teve maior escore, bem como que o ruído pode ser considerado como variável que influencia o presenteísmo. Dentre as variáveis significativas estão dor de cabeça, dor nas costas, percepção de saúde, sono, bem-estar, tensão no trabalho, turno de trabalho e sexo. Pretendeu-se com esta pesquisa contri... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Production and risk factors that interfere with worker productivity have been discussed as a strategic factor in the management of companies. The presenteeism aims to analyze which are the health factors that interfere in the productivity of the worker. Occupational noise is a reality in which workers are exposed daily and in which there is scientific evidence of the effect of noise on employee health. This study aims to investigate the association between sociodemographic variables and work with the occurrence of presenteeism and the association with exposure to occupational noise. For this study, the research was characterized as exploratory, with a quantitative approach. A case study was conducted in an industry located in Vale do Paraíba, with a sample of 320 subjects. The data were obtained through the application of the WLQ protocol of presenteeism, the sociodemographic data questionnaire and documents about the noise provided by the company. The association analysis of the outcomes was performed using multivariate logistic regression and with significance level of 5%. It can be verified that the physical demand was the one that had the highest score, as well as that the noise can be considered as a variable that influences the presenteeism. Among the significant variables are headache, back pain, health perception, sleep, well-being, tension at work, work shift and sex. This research aimed to contribute to the search for improvements in what relates to worker's product... (Complete abstract click electronic access below) / Doutor
238

Proposta de programa de prevenção de perdas auditivas para músicos

Munhoz, Graziella Simeão 16 February 2016 (has links)
INTRODUÇÃO: A audição é um dos sentidos mais importantes para o ser humano, e seu funcionamento está interligado à sua produtividade, o que não é diferente aos músicos, já que ela é de suma importância para a qualidade de seu trabalho e permanência na carreira. O desenvolvimento de um programa de prevenção de perdas auditivas tem por objetivo modificar o comportamento dos músicos em relação à sua audição, uma vez que, constantemente, estão expostos a níveis de pressão sonora elevados e ao surgimento de lesões irreversíveis. Contudo, se medidas preventivas não forem realizadas corretamente, as exposições dos músicos frente à intensidade sonora elevada podem trazer prejuízos à saúde e alguns destes, irreversíveis como, a Perda Auditiva Induzida por Níveis de Pressão Sonora Elevados (PAINPSE) ou Perda Auditiva Induzida por Música (PAIM). OBJETIVO GERAL: submeter os músicos ao programa de prevenção de perdas auditivas (PPPA) e verificar sua eficácia. MATERIAL E MÉTODOS: Participaram componentes de quatro bandas musicais, correspondendo a um total de 16 participantes. Esses membros foram submetidos ao Programa de Prevenção de Perdas Auditivas (PPPA) que engloba as seguintes etapas: (1) medição do nível de pressão sonora no ensaio e show; (2) entrevista específica, Audiometria Tonal Liminar e de Altas Frequências, Logoaudiometria, Imitanciometria e Emissões Otoacústicas por estímulo Transientes e Produto de Distorção; (3) orientação sobre a utilização do Equipamento de Proteção Individual (EPI); e (4) a realização de medidas educativas por meio de workshops. RESULTADOS: O Nível de Pressão Sonora (NPS) durante os ensaios e apresentações/shows, encontram-se elevados, sintomas não auditivos estão presentes em 68, 75% da população total da amostra, presença de zumbido após o show em 100% da amostra; maiores dificuldades de compreensão de fala no ruído nos músicos que tocam baixo (75%). Ao traçar o perfil audiológico do músico foram encontrados: maiores médias dos limiares audiológicos por frequência das bandas estudadas em 500Hz e 3KHz (B1), 3KHz e 4KHz (B2), 3KHz, 4KHz e 6KHz (B3) e em 3KHz (B4); as maiores médias dos limiares audiológicos por frequência dos instrumentos estudados foram em 3KHz, 4KHz e 6KHz (voz), 3KHz e 4KHz (guitarra), 3KHz, 4KHz e 6KHz (baixo) e 3KHz, 4KHz (bateria); presença de entalhe nas frequências de 2KHz, 4KHz, 6KHz e 8KHz na audiometria tonal liminar; já na audiometria de altas frequências em todas as frequências apareceram ao menos um caso, reflexos ausentes em 4KHz (ipsilateral e contralateral); ausência de resposta em 4KHz para todos os baixistas bilateralmente (100%) quando pesquisado EOE por estímulo transiente e na produto de distorção foram encontradas ausência de respostas em 50% da amostra na frequência de 6KHz, sendo assim pesquisada a curva de crescimento (dp growth rate) aparecendo resposta em 75dB em quase 100% dos casos em que houve necessidade de sua realização. Quanto aos achados obtidos da avaliação realizada pelos participantes (músicos) referente ao website, os resultados mostraram que o mesmo atende às necessidades propostas, ou seja, a promoção da saúde auditiva em músicos. CONCLUSÃO: Existe a necessidade de serem tomadas medidas preventivas e a inserção dos músicos em um Programa de Prevenção de Perdas Auditivas (PPPA) a fim de proporcioná-los maiores condições de qualidade de vida e em seu trabalho, já que necessitam da sua audição para desempenhar com eficácia suas atividades e se manter no mercado de trabalho atuando como músico. / INTRODUCTION: Hearing is one of the most important senses for the human being, and its operation is interconnected to its productivity, which is no different to the musicians, since it is of the utmost importance for the quality of their work The development of a hearing loss prevention program, aims to modify the musicians behavior in relation to their hearing, once, constantly, are exposed to high sound pressure levels and the emergence of permanent injury. However, if preventives measures are not performed correctly, the exposures of the musicians facing the high sound intensity can bring losses to health and some of these, irreversible such as, Hearing Loss Induced by High Sound Pressure Levels (HLIHSPL) or Music-induced hearing loss (MIHL) - Noise-Induced Hearing Loss (NIHL). GENERAL OBJECTIVE: submit the musicians to the Hearing Loss Prevention Program (HLPP) and verify its effectiveness. MATERIAL AND METHODS: participated components from four musical bands, corresponding to a total of 16 participants. These members were submitted to the Hearing Loss Prevention Program (PPPA) that include the following steps: (1) measurement of the sound pressure level at the rehearsal and concert; (2) specific interview, Pure Tone Audiometry and High Frequencies, Logoaudiometry, Imitanciometry and Distortion Product Evoked Otoacoustic Emissions (DPEOE); (3) guidance on the use of Personal Protective Equipment (PPE); and (4) the achievement of educational measures through workshops. RESULTS: The Sound Pressure Level (SPL) during the rehearsals and performances/shows are elevated, symptoms not auditory are presents in 68,75% of the total sample population, presence of tinnitus after the show in 100% of the sample; major difficulties of speech comprehension in the noise of the musicians who playing bass (75%). When plotting the audiological profile of the musician were found: highest averages of audiological thresholds by frequency from the studied bands in 500Hz and 3KHz (B1), 3KHz and 4KHz (B2), 3KHz, 4KHz and 6KHz (B3) and in 3KHz (B4); the major averages of audiological frequency thresholds of the studied instruments were in 3KHz, 4KHz and 6KHz (voice), 3KHz and 4KHz (electric guitar), 3KHz, 4KHz and 6KHz (bass) and 3KHz, 4KHz (drums); presence of notch in the frequencies of 2KHz, 4KHz, 6KHz and 8 kHz in the pure tone audiometry; but in the high audiometry frequencies, in all frequencies appeared at least one case, missing reflexes in 4KHz (ipsilateral and contralateral); missing reply in 4KHz for all bassists bilaterally (100%) when researched EOE by transient stimulus and in the distortion product were found missing responses in 50% of the frequency sample of 6KHz, so researched the growth curve (dp growth rate) showing response in 75dB at almost 100% of cases which there was need for its achievement. CONCLUSION: there is a need to take preventive measures and the insertion of the musicians in the Hearing Loss Prevention Program (HLPP) in order to provide them greater conditions of quality of life and in their work, since they need their hearing to play effectively their activities and stay in the labor market working as a musician.
239

Incidência de perda auditiva induzida por ruído ocupacional entre trabalhadores de uma mineradora e pelotizadora de minério de ferro / Incidence of hearing loss induced by occupational noise among workers in a company engaged in iron ore mining and pelletizing

Amaral, Bruno Vianna do 03 September 2014 (has links)
INTRODUÇÃO: Em consequência da modernização tecnológica e industrial, surgiram novos fatores que originaram estudos específicos e direcionados sobre os possíveis efeitos nocivos desta evolução no trabalhador. Dentre estes, está o ruído, agente físico que pode causar danos ao organismo humano com efeitos de curto e médio prazo. O ruído, ao atuar sobre o trabalhador pode alterar processos internos do organismo, com consequências fisiológicas e emocionais. A diminuição gradual da acuidade auditiva decorrente da exposição continuada a níveis elevados de pressão sonora é denominada perda auditiva induzida pelo ruído (PAIR), segundo o Comitê Nacional de Ruído e Conservação Auditiva. A PAIR é caracterizada por perda neurossensorial, irreversível, quase sempre bilateral e simétrica, não ultrapassando 40dB(NA) nas frequências graves e 75dB(NA) nas frequências agudas; manifesta-se, primeiramente, em 6kHz, 4kHz e/ou 3kHz, progredindo lentamente às frequências de 8kHz, 2kHz, 1kHz, 500Hz e 250Hz. (MTE, Portaria 19, 1998). Entre os fatores que influenciam no desencadeamento da PAIR, destacam-se as características físicas do ruído (tipo, espectro e intensidade da pressão sonora), o tempo de exposição e a suscetibilidade individual. A PAIR está entre as doenças do trabalho de maior prevalência, com agravante de tratar-se de uma doença irreversível. Acomete com mais frequência o setor industrial. Este estudo avalia a incidência de perda auditiva por ruído e a existência de uma associação positiva entre estes diagnósticos e a exposição a diferentes níveis de pressão sonora em trabalhadores de duas unidades de uma mineradora e pelotizadora de minério de ferro. MÉTODOS: Estudo de coorte histórica com 1.069 trabalhadores divididos em dois grupos, tendo como referência os níveis de pressão sonora aos quais estavam expostos (menor ou igual a 88 dB e acima de 88 dB). A avaliação da audição foi realizada por análise dos resultados das audiometrias realizadas nos exames admissionais e periódicos constantes dos prontuários médicos. Foram calculadas as incidências de perda auditiva de acordo com os grupos de exposição e o tempo médio de início das alterações auditivas em cada grupo. Foram realizadas análises descritivas das variáveis, comparação de médias (teste U de Mann-Whitney), teste de associação de qui-quadrado e, para estimar fatores de risco, modelos de regressão logística univariada e múltipla. RESULTADOS: Entre os participantes do estudo foram identificados 128 casos (11,97%) de perda auditiva. No grupo composto pelos trabalhadores que ficaram expostos aos níveis mais altos de pressão sonora encontra-se uma incidência de 11,84% em alterações de exames audiométricos, enquanto no grupo menos exposto obteve-se uma incidência de 12,4%. O tempo médio para o desencadeamento de alterações audiométricas foi de 3,07 anos (desvio padrão = 1,21) no grupo mais exposto e de 2,88 anos (desvio padrão = 1,53) no grupo menos exposto. Estar na faixa etária acima de 28 anos e 8 meses (RC = 3,33; IC 95%: 2,01 - 5,49) e trabalhar na Unidade 1 (RC = 1,64; IC 95%: 1,09 - 2,46) se mostraram fatores de risco robustos para perda auditiva induzida por ruído. CONCLUSÃO: A perda auditiva ocorre de maneira precoce, prioritariamente até o terceiro ano de exposição e faixa etária, e unidade de trabalho se mostraram os fatores de risco mais relevantes para a perda auditiva induzida por ruído. O estudo mostra a necessidade de uma integração maior entre as áreas de saúde ocupacional e segurança do trabalho na busca de ações preventivas e corretivas, que possam minimizar o surgimento de novos casos ou o agravamento dos já identificados. Este é um estudo preliminar que servirá de apoio a pesquisas futuras sobre o assunto / INTRODUCTION: As a result of technological and industrial modernization new factors have arisen which led to specific studies have focused on the possible harmful effects of this evolution on the worker. Among these factors is noise, a physical agent which can harm the human body with short and medium term effects. Noise can alter internal body processes, with physiological and emotional consequences. The gradual reduction of hearing acuity resulting from a continued exposure to high levels of noise pressure is called noise-induced hearing loss (NIHL), according to the National Committee of Noise and Hearing Conservation. NIHL is characterized by a permanent sensorioneural impairment, almost always bilateral and symmetrical, not exceeding 40dB (NA) at lower frequencies and 75dB (NA) at higher frequencies. It first manifests at 6kHz, 4kHz and/or 3kHz, slowly progressing to the frequencies of 8kHz, 2kHz, 1kHz, 500Hz and 250Hz. (MTE, Ruling 19, 1998). Among the factors which trigger NIHL are the physical characteristics of the noise (type, spectrum and intensity of sound pressure), duration of exposure, and individual susceptibility. NIHL is among the most common occupational diseases, with the aggravating aspect of being irreversible. It is most often found in the industrial sector. This study will evaluate the incidence of noise-induced hearing loss and the existence of a positive association between these diagnoses and the exposure to different levels of sound pressure in workers at two operational units of a iron ore mining and pelletizing organization. METHODS: historical cohort study with 1069 workers, divided in two groups, using as baseline the sound pressure levels to which they were exposed (less than or equal to 88 dB and above 88 dB). The hearing assessment was carried out by means of an analysis of the results of the audiometry exam upon induction and at regular intervals, as recorded in the medical history of the individual. A calculation was made of the degree of hearing loss according to the groups of exposure, and the average time it took for hearing changes to be observed in each group. RESULTS: Among the participants in the study, 128 (11.97%) cases of hearing loss were identified. In the group formed by workers who had been exposed to the highest levels of sound pressures, we found an incidence of 11.84% of changes in the audiometry exams, while in the group subject to lesser exposure we observed an incidence of 12.4%. The average time for the development of hearing impairment was 3.07 years (standard deviation = 1.21) in the group with greater exposure, and 2.88 years (standard deviation = 1.53) in the group with lesser exposure. Robust risk factors for noise-induced hearing loss included being aged over 28 years and 8 months (RC = 3,33; IC 95%: 2,01 - 5,49) and working at Unit 1 (RC = 1,64 ; IC 95%: 1,09 - 2,46). CONCLUSION: Early hearing impairment occurs mainly before the end of the third year of exposure, and age bracket and work location proved to be the most relevant risk factors for noise-induced hearing loss. The study showed the need for a greater integration among the occupational health and safety areas to seek the design and implementation of preventive and corrective actions to minimize the development of new cases or the aggravation of those already identified. This is a preliminary study which will serve as a basis for a more detailed subsequent data analysis
240

Poluição sonora urbana: a influência de modificações em escapamentos de motocicletas na emissão de ruído / Urban noise pollution: influence of modifications on exhaust systems for noise emission

Forcetto, André Luiz Silva 11 April 2016 (has links)
A poluição sonora urbana, em especial a gerada por motocicletas com escapamentos modificados, afeta indistintamente a saúde de toda população de diversas maneiras e tende a aumentar, ao contrário da emissão de gases, que vem se reduzindo ao longo dos anos. Com o objetivo de conter o ruído gerado pelo tráfego urbano, vários países desenvolvem procedimentos, leis e ações mitigatórias como barreiras acústicas e asfaltos fonoabsorventes, porém há grande quantidade de motocicletas, veículo tipicamente de alto potencial de incômodo e ruidoso, que circulam com sistemas de escapamento adulterados e emitem ainda mais excesso de ruído. A inspeção veicular é ferramenta importante no controle de emissões de gases poluentes de veículos em uso, mas falha em restringir aqueles que ultrapassam os limites legais de ruído e, somado a isto, há o agravante de o condutor submeter-se a poluição sonora que ele mesmo produz. A fiscalização de rua surge como alternativa de controle ambiental, mas algumas vezes é contestada por ser subjetiva ou por faltar uma metodologia simples, confiável e eficaz. Buscou-se então compreender a relação entre o aumento do nível sonoro da motocicleta com escapamento modificado ao circular no trânsito e a emissão sonora medida na condição de inspeção, o chamado ruído parado, para trazer subsídios à formação de métodos mais eficazes de fiscalização e controle. Para isto foram avaliadas motocicletas quanto à emissão de ruído em circulação e ruído parado e os resultados obtidos apontam que os escapamentos modificados possuem nível sonoro muito mais elevado que os originais, com forte correspondência entre os dois métodos de medição. Esta poluição sonora atinge de modo particularmente intenso os profissionais, motoboys, que modificam suas motocicletas, pois eles se submetem a todos os fatores que favorecem a perda auditiva por excesso de ruído. Outras questões surgiram em paralelo ao tema principal e foram brevemente avaliadas para se compor o quadro geral, como o nível sonoro de escapamentos não originais avaliados segundo os procedimentos de homologação, a contribuição que a motocicleta traz ao ruído urbano e que resultados estes trazem quanto ao torque e potência da motocicleta. Estes estudos indicaram que a motocicleta modificada contribui fortemente para a poluição sonora urbana, afetando principalmente o condutor e sem trazer ganhos efetivos em termos de potência e dirigibilidade. / The urban noise pollution, in particular the one produced for motorcycles with tampered exhaust systems, affects indistinctly the health of all people in many ways and tends to grow up, in opposite to gaseous emissions, that is getting down through years. With the goal of mitigate noise generated from urban traffic, many countries develop procedures, laws and actions as acoustic barrier and phono absorbent asphalt, but there are still a great amount of motorcycles, typically a high annoying and noisy vehicle, running with tampered mufflers and producing excessive noise. In use vehicle inspection is an important tool on gaseous emissions control but fails to restrain excessive noise, a problem that get worse up due the rider is subjects him/herself to the own sound pollution. Roadside control comes as an alternative but sometimes is rejected as subjective or due a lack of a simple, easy, trustable method. This research looks for the relationship between increased sound level of modified motorcycles in traffic and noise emission in inspection mode, also known as stationary noise, to bring subsidies to develop more efficient control methods. For this, it were evaluated motorcycles for traffic and stationary noise emission and the results point that modified exhaust systems have a very higher sound level than original mufflers, with strong relationship between these two measurement methods. This sound pollution affects in a very special mode the professionals, called in Brazil motoboys, which modify their motorcycles, because they subjected themselves to all factors for noise-induced hearing loss. Other questions come in parallel to the main focus and were briefly studied in order to compound the whole picture as sound level of replacement mufflers according homologation procedures, the motorcycle contribution to the urban sound pollution and the results for power and torque. These studies point to that modified motorcycles strongly contribute to urban noise, affecting especially the driver and with no effective gain in engine power and motorcycle handling.

Page generated in 0.0781 seconds