Desenvolvimento de processo para incorporação da etapa de otimização de parâmetros analíticos em procedimentos automatizados de análises por injeção sequencialSoares, Vitória Regina Bispo January 2009 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-08-31T12:55:32Z
No. of bitstreams: 1
Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-02T15:48:05Z (GMT) No. of bitstreams: 1
Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / Made available in DSpace on 2016-09-02T15:48:05Z (GMT). No. of bitstreams: 1
Dissertação de Vitória Regina B. Soares.pdf: 4140552 bytes, checksum: cfbde6e68fae6f80c2843951ea61ffde (MD5) / CNPq / Para aumentar o nível de automatização no desenvolvimento de procedimentos analíticos
em sistemas de análises por injeção sequencial foi proposta uma rotina em linguagem
QuickBasic que permitia incorporar a etapa de otimização multivariada como uma das
etapas do processo analítico, simplificando o gerenciamento do sistema. A rotina foi
desenvolvida para sistemas de análises por injeção sequencial, uma vez que esta estratégia
de análises em fluxo pode executar diferentes procedimentos sem reconfiguração do
sistema. O processo automatizado de otimização, calibração e medida foi aplicado para as
determinações espectrofotométricas de ferro total e de captopril em medicamentos,
empregando os métodos da 1,10-o-fenantrolina e do acoplamento com o radical
iminoquinona, respectivamente. Para rotina de otimização desenvolvida foi selecionado o
sinal líquido como resposta e a intervenção do operador se restringiu a selecionar as
variáveis do sistema sob otimização, definir os domínios experimentais de cada variável e
escolher o desenho experimental a ser executado. Entretanto, caso as condições ótimas
não fossem encontradas no domínio experimental selecionado a rotina foi programada de
modo a sugerir ao operador os deslocamentos que deveriam ser feitos nos domínios
experimentais. Os fatores investigados para a determinação de ferro total em amostras de
fortificantes foram os volumes amostrados dos reagentes e a vazão da solução
transportadora, enquanto que para o captopril foram investigados os volumes amostrados
dos reagentes, a acidez da solução do oxidante e da solução da amina aromática, além da
vazão da solução transportadora. Nas condições otimizadas os graus de sopreposição de
zonas para ambos os procedimentos variaram entre 0,79 e 1, indicando a eficiente mistura
das soluções das amostras e reagentes no percurso analítico. O procedimento SIA
otimizado para a determinação do teor de ferro total em fortificantes apresentou baixa
dispersão (<2%), limite de quantificação de 1,43 mg L-1 , com consumo de 0,7 mg de 1,10-o-
fenantrolina e 6 mg de ácido ascórbico por determinação. A freqüência analítica foi de 60
determinações h-1 e os resultados obtidos para diferentes amostras de fortificantes foram
comparados com o mesmo método em batelada e não apresentaram diferenças
significativas para 95% de confiabilidade. Trinta determinações de captopril em produtos
farmacêuticos por hora de trabalho foram executadas pelo procedimento de análise por
injeção seqüencial otimizado consumindo 0,15 mg de sulfato de N-N-dimetil-p-fenilodiamina
(DMPD) e 4 mg de FeCl3.6H2O por determinação. Faixa linear de trabalho entre 2,65 e 100
mg L-1 e boa precisão (ca. 1%) foram também obtidas. Os teores de captopril em amostras
de produtos farmacêuticos foram determinados pelo procedimento proposto e os resultados,
quando comparados com o método iodométrico de referência, não apresentaram diferenças
significativa para 95% de confiança / A QuickBasic routine was proposed to increase the automatization in the development of
analytical process for sequential injection analysis system in order to permit the inclusion of
multivariated optimization as one of the steps of analytical process leading to simplify the
system management. The routine was developed for sequential injection analysis once this
flow analysis strategy can perform diverse analytical procedures in the same manifold. The
automatized process for optimization, calibration and measurement was applied to determine
the total iron concentration in pharmaceutical formulations by 1,10-o-phenantroline
spectrophotometric method, as well as captopril in pharmaceutical formulations based on
coupling reaction with iminoquinone radical. Sensitivity (net signal) was selected as
dependent parameter for the optimization step and the analyst action was limited to select
the parameters to be optimized and the experimental design to be used as well to define the
experimental domains of all parameters. A decision of the analyst was also expected in the
cases where the optimal conditions were not attained in the domains previously selected
and, once new domains are suggested by the software, a new sequence of experiments will
be carried out with human agreement. Aliquots volumes of reagents and carrier solution flow
rate were the parameters evaluated for total iron determination in supplements, while the
acidity and volumes of reagents solutions and the flow rate of carrier solution were optimized
for captopril determination flow procedure. For both analytical procedures in the optimized
conditions the index of zone overlapping was varied from 0.79 and 1, suggesting an efficient
mixture of solutions in the analytical path. The optimized SIA procedure for total iron
determination in supplement samples has low dispersion (<2%), limit of quantification of 1.43
mg L-1, leading to consume 0.7 mg of 1,10-o-phenantroline and 6 mg of ascorbic acid per
determination. An analytical throughput of 60 determinations h-1 was estimated and no
significant difference (95% confidence level) was observed by comparing the results
obtained by the flow method in optimized conditions and those obtained by the
spectrophotometric procedure in batch mode. Thirty captopril determinations in
pharmaceutical formulations per hour were carried out by employing the optimized sequential
injection analysis procedure, consuming 0.15 mg of N,N-dimethyl-p-phenylenediamine
(DMPD) and 4 mg of FeCl3.6H2O. Linear range from 2.65 to 100 mg L-1 with high precision
(ca. 1%) was also obtained and no significant differences (95% confidence level) were
observed by comparing the optimized flow procedure with the iodometric reference method.
|
32 |
A derivatização na determinação de proteínas e aminoácidos em fluidos biológicos / Derivatization in the determination of proteins and amino acids in biological fluidsOrlando Guarilha Junior 06 June 2003 (has links)
No presente trabalho são apresentadas análises de amostras de proteínas totais e aminoácidos empregando-se os reagentes p-benzoquinona e tetraamin cobre (II). No caso do reagente p-benzoquinona, as análises foram feitas através de um sistema inédito em fluxo, no qual a mistura reacional passava através de um reator composto de um tubo capilar de aço inoxidável aquecido num banho de glicerina. Os derivados formados passavam através de uma cela de fluxo acoplada a um espectrofotômetro, onde eram feitas as leituras das absorbâncias. Este método se mostrou mais rápido em relação àquele feito em banho-maria. A utilização de um sistema de análise por injeção em fluxo (FIA) com o reagente tetraamin cobre (II), permitiu que as análises fossem feitas de forma rápida, a baixo custo e com a vantagem de não necessitarem de aquecimento, como no caso da p-benzoquinona. Os resultados das análises de amostras de albumina humana obtidos em ambos os métodos acima apresentaram boa concordância quando comparados àqueles obtidos pelo método Kjeldahl para as mesmas amostras. / This work describes two methods for analysis of total proteins and aminoacids using both p-benzoquinone (PBQ) and tetraamin copper (II) reagents. With the p-benzoquinone reagent the method was performed by an original flow system made with stainless steel capillary tubing, conveniently heated into a glycerin bath, where the reactional mixture travels in its way to the detector. The derivate products are carried out to a flow cell adjusted to a spectrophotometer where the absorbances are measured. This method was efficient, with a fair cost, and providing results very faster than in the batch mode of operation. The second method, using the tetraamin copper (II) reagent, was performed by a common flow injection system (FIA). When compared with the PBQ method, the FIA tetramin copper (II) method was also rapid, efficient, with a fair cost and with the great advantage of simplicity, once it is performed at room temperature. The results obtained with human albumine samples using both methods are in agreement with those ones obtained by the Kjeldahl method for the same samples.
|
33 |
Développement d’un lab-on-chip pour la mesure d’acidité libre de solutions chargées en cations hydrolysables / Development of a lab-on-chip for free acidity measurement in aqueous solutions containing hydrolytic cationsNeri Quiroz, José Antonio 25 November 2016 (has links)
Une étude conjointe du CEA et d'AREVA la Hague a montré qu'une des voies d'amélioration majeure des usines de traitement/recyclage du combustible nucléaire usagé, actuelles et futures, concerné le domaine de l'analyse. En effet, le suivi et le pilotage des procédés déployés dans ces usines nécessitent de nombreuses analyses générant de grandes quantités d'effluents radioactifs. Réduire les volumes mis en jeu lors de ces analyses permettrait donc de réduire la nocivité des échantillons et des effluents et donc d'accroitre la sureté pour le personnel et de réduire l'impact sur l'environnement et le coût de fonctionnement des usines. Parmi toutes les analyses effectuées, la mesure d'acidité libre est la plus fréquente, car c'est un paramètre indispensable pour pouvoir piloter correctement le procédé. C'est pourquoi, ces travaux de thèse ont abouti à l'amélioration de la méthode de mesure via une réduction d'échelle de l'analyse et une automatisation du protocole de mesure. Deux voies ont été étudiées : - le titrage par injection séquentielle (SIA), qui est un dispositif de 25 L de volume et qui par rapport à la méthode d'analyse de référence, réduit 1000 fois le volume d'échantillon nécessaire à l'analyse, 8 fois le temps d'analyse et 40 fois le volume d'effluents générés. - le titrage ballist-mix emploie un dispositif microfluidique qui, après intégration et réduction des composants, peut atteindre un volume de 25 mL et offre des performances analytiques comparables à celles obtenues en SIA. La méthode par SIA a été validée sur des solutions chargées en uranium alors que la technologie utilisée pour développer les titrages ballist-mix est en cours de validation. Cependant le principe opératoire du titrage ballist-mix est plus avantageux puisqu'il simplifie le travail de développement analytique du fait de la possibilité de simuler en avance les phénomènes physicochimiques ayant lieu lors du titrage / A joint study between the CEA and Areva La Hague has shown that chemical analysis is a crucial parameter for achieving a better performance in present and future spent nuclear fuel reprocessing plants. In fact, each plant’s process monitoring and control require a significant amount of laboratory analysis leading in overall to a considerable amount of nuclear waste. Hence, reducing the sample’s required volume for analysis would reduce its toxicity and subsequent waste, therefore increasing personnel safety, decreasing the environmental impact and the plant’s operation cost. Among the process control analytical workload, the free acidity measurement has been identified as a key analysis due to its measurement frequency. For this reason, the main objective of this research has been focused in the improvement of a reference method for free acidity measurement. The following work has been divided in two main studies seeking for the reduction of the sample volume and the automation of the analytical method protocol: - Sequential Injection Analysis (SIA) titration, whose application requires the employment of a device occupying a 25 L space, and which reduces 1000 fold the sample volume per analysis, 8 times the analysis time and 40 fold the amount of waste generated when compared to the reference analytical method. - Ballist-mix titration, whose analytical performance is equivalent to the SIA titration, but whose implementation is done inside a microfluidic device occupying a volume as low as 25 mL after integration of all of the elements needed for analysis. At the present time, the SIA titration has been validated using nitric acid samples containing uranyl cations, whereas the ballist-mix titration is being validated with the same sample conditions. However, this last analytical technique features a simplified operating principle which allows the user to shorten the analytical development process by opening the possibility to simulate the process before any experimentation
|
34 |
Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and wasteGalhardo, Cristiane Xavier 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.
|
35 |
Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and wasteCristiane Xavier Galhardo 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.
|