• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 18
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 60
  • 60
  • 32
  • 31
  • 29
  • 19
  • 17
  • 14
  • 14
  • 12
  • 11
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Projeto conceitual de uma célula flexível de manufatura para acabamento de instrumentos cirúrgicos por Sandro Dias Vieira

Vieira, Sandro Dias January 2011 (has links)
Neste trabalho foram utilizados os conceitos de célula flexível de manufatura e de automação utilizando a robótica para desenvolver uma célula robotizada de acabamento de instrumentos cirúrgicos forjados, com o objetivo de obter aumento de produção e flexibilizar o sistema de manufatura. Na produção manual de acabamento dos instrumentos cirúrgicos incluídos no estudo são realizados processos de lixamento, eletropolimento, polimento vibratório, jateamento e polimento com manta sintética e escova. Foi identificado que o sistema utilizando trabalho manual restringe a produtividade a um número de pinças insuficiente para atender à demanda do mercado. Desse modo, foi desenvolvida uma célula robotizada de acabamento, com a intenção de suprir a necessidade do aumento de produção dos instrumentos cirúrgicos. Em paralelo ao desenvolvimento da célula flexível de manufatura, estudaram-se os processos de acabamento utilizados, resultando na eliminação de etapas de acabamento no processo automatizado. Com a célula flexível de manufatura desenvolvida se obteve um aumento de produção de 96,87 % e uma redução nos custos de 50,53 % em relação à linha manual. Os produtos cuja manufatura se deseja automatizar são pinças hemostáticas, de apreensão e de campo que foram selecionadas através da análise da demanda produtiva. A matéria-prima utilizada nestes instrumentos é aço inoxidável martensítico, de denominação AISI 420D. O processo de fabricação utilizado nos componentes é o forjamento, que permite a melhora das propriedades mecânicas, modificando a disposição dos constituintes do material deformado. No entanto, foi avaliada de forma experimental a viabilidade de substituição do forjamento pelo corte laser, visando a eliminação do processo de lixamento dos componentes, com consequente aumento na taxa de produção, o que não foi possível devido à menor resistência obtida pelos componentes assim produzidos. / In this study, were used the concepts of flexible cell manufacturing and automation using robotics to develop a finishing in forged surgical instruments robot cell, in order to get increased production and a more flexible manufacturing system. On completion of the manual production of surgical instruments included in the study of processes are performed grinding, electropolishing, vibratory polishing, sandblasting and polishing synthetic blanket and brush. Was identified that the system using manual labor productivity to a limited number of tweezers insufficient to meet market demand. Thus, was developed a robotic finishing cell, with the intention of meeting the need for increasing production of surgical instruments. In parallel to the development of flexible manufacturing cell, were studied the finishing processes used, resulting in the elimination of finishing steps in the automated process. With the flexible manufacturing cell development was obtained an increase of 96.87% and production cost savings of 50.53% compared to the online manual. The products whose manufacture is desirable to automate hemostat, apprehension and field tweezers that were selected by analyzing the production demand. The raw material used in these instruments is martensitic stainless steel, designations AISI 420D. The manufacturing process used in the components is forginig, which allows the improvement of mechanical properties by modifying the arrangement of the constituents of the deformed material. However, it was experimentally evaluated the feasibility of replacing the forging by laser cutting, in order to eliminate the process of grinding the components, with consequent increase in production rate, which was not possible due to a lower resistance obtained by the components thus produced.
22

Att skapa sitt eget system - operationssjuksköterskors erfarenheter vid uppdukning av kirurgiska instrument - : en kvalitativ intervjustudie / Creating your own system - operating room nurses' experiences of setting up surgical instruments - : a qualitative interview study

Nordström, Marielle, Ots, Karen January 2022 (has links)
Bakgrund: I Sverige genomförs årligen hundratusentals operationer. Vid dessa operationer behövs kirurgiska instrument samt en operationssjuksköterska som är ansvarig för hur de kirurgiska instrumenten iordningställs inför operationen. Uppdukningen av de kirurgiska instrumenten är en stor del i operationssjuksköterskans arbete. Det är viktigt att veta vilka instrument som ska dukas upp, deras användningsområde och vart de placeras. Det finns olika direktiv angående hur uppdukningen ska utföras. Motiv: Få studier är genomförda där operationssjuksköterskornas erfarenhet och upplevelse av uppdukning är beskrivna. Denna studie kan resultera i ökad kunskap om hur operationssjuksköterskan upplever uppdukning av kirurgiska instrument och hur det påverkar operationssjuksköterskans arbetssituation.  Syfte: Syftet med studien är att beskriva operationssjuksköterskans erfarenhet vid uppdukning av kirurgiska instrument. Metod: Individuella semistrukturerade intervjuer med åtta operationssjuksköterskor. Intervjuerna analyserades med kvalitativ innehållsanalys.   Resultat: Deltagarnas upplevelser och erfarenheter av att duka upp kirurgiska instrument beskriver hur de byggt upp deras eget uppdukningssystem baserat på klinisk erfarenhet. Att jobba efter ett eget system inbringade en känsla av trygghet och kontroll men trots detta fanns situationer i processen som gjorde att otrygghet och brist på kontroll upplevdes. Från intervjuerna identifierades tre huvudkategorier; Att forma ett eget system, Att arbeta efter ett eget system, Att gå ifrån sitt eget system. Konklusion: Att uppleva trygghet och kontroll vid uppdukning av kirurgiska instrument var viktigt för operationssjuksköterskorna. Det framkom faktorer som påverkar känslan av trygghet och kontroll både positivt och negativt. För att erhålla klinisk kompetens inom området krävs omfattande klinisk erfarenhet.   Nyckelord: Operationssjuksköterska, Erfarenheter, Kirurgiska instrument, Kvalitativ innehållsanalys / Background: In Sweden, hundreds of thousands of operations are conducted yearly. Each operation needs surgical instruments and an operating room nurse who is responsible for setting up and organizing the instruments prior to the operation. Setting up surgical instruments is an integral part of the operating room nurses’ responsibility. To set up the instruments it is of importance to know which instrument is needed for the operation, how the instrument is used, and where it should be placed. Practice guidelines differ in their recommendations regarding how surgical instruments should be set-up and organized prior to the operation. Motive: There is limited research about operating room nurses’ experiences of setting up and organizing surgical instruments. This study can result in increased understanding regarding how operating room nurses’ experience set-up of surgical instruments and how this affects their working environment.   Aim: The aim of this study is to describe operating room nurses’ experiences of setting up and organizing surgical instruments. Methods: Individual semi-structured interviews were conducted with eight operating room nurses. The interviews were analyzed with qualitative content analysis. Result: The participants' experiences of setting up and organizing surgical instruments describe how they build up their own organizational system based upon clinical experience. While utilizing their own system they experience a sense of security and control. However, there are situations in which feelings of insecurity and lack of control can occur. The interviews identified three main categories; Forming your own system, Working with your own system, Working outside your own system. Conclusion: Experiencing security and control related to set-up and organization of instruments was considered important for the operating room nurses. Factors were identified that affect the operating room nurses’ feelings of security and control both positively and negatively. Substantial clinical experience is necessary to achieve clinical competence setting up and organizing surgical instruments.  Keywords: Perioperative nursing, Experiences, Surgical instruments, Qualitative content analysis
23

Instrumental ortopédico de conformação complexa: avaliação do processamento, formação de biofilme e suas implicações / Orthopedic instruments of complex conformation: evaluation of the processing, formation of biofilm and its implications

Lopes, Lillian Kelly de Oliveira 20 December 2016 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-05-12T17:43:06Z No. of bitstreams: 2 Tese - Lillian Kelly de Oliveira Lopes - 2016.pdf: 5335353 bytes, checksum: f43aa281ba6ba16a4f2f6d881c9c2bac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-05-15T11:47:47Z (GMT) No. of bitstreams: 2 Tese - Lillian Kelly de Oliveira Lopes - 2016.pdf: 5335353 bytes, checksum: f43aa281ba6ba16a4f2f6d881c9c2bac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-15T11:47:47Z (GMT). No. of bitstreams: 2 Tese - Lillian Kelly de Oliveira Lopes - 2016.pdf: 5335353 bytes, checksum: f43aa281ba6ba16a4f2f6d881c9c2bac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-12-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Outro / INTRODUCTION: Depth gauge and flexible drill bite cutter are orthopedic surgical instruments of complex conformation and they are into loanered instrumentation box to different healthcare facilites. The challenge is to ensure that appropriatly cleaning was done to prevent the formation of biofilm in these instruments´models. There are no experimental or clinical studies analyzing the impact of different cleaning protocols on formation of biofilm on surfaces those two surgical instruments. OBJECTIVES: To validate and to evaluate laboratory method to formation of biofilms in stainless steel. To evaluate microbial load and to determine formation of biofilms after laboratory contamination and processing for several cycles in surgical instruments of complex conformation used in surgeries of orthopedic implants. METHOD: Experimental study was developed from November/2014 to March/2016, at the Laboratory of Macquarie University, Sydney (AU). Method´s validation: new forceps halsted hemostatic mosquito were contaminated within contaminant solution containing S. aureus (ATCC 25923) and sterilized in saturated steam. Forceps were divided into three groups according to cleaning: 1) rinsing, 2) manual cleaning and 3) manual cleaning followed by automated cleaning. After 6th, 13th and 20th three forceps from each protocol were analised for microbial load and protein amount (Bicinchoninic Acid Assay) and visual analysis by scanning electronic microscopy. The same method was used on new flexible drill bite cutters and depth gauges, and analised after 10th and 20th reprocessing. RESULTS: Method´s validation: forceps submitted to protocols 1 (positive control of cleaning) and 2 showed coccus in biofilms and forceps sumitted to protocol 3 showed organics residues after 20 reprocessing. No microbial load or residual protein was found. Complex instruments: flexible drill bite cutters submitted to rinsing presented high amount of protein with increase of 1699μg of protein from 10th to 20th reprocessing (P = 0.03). Depth gauge submitted protocol 1 presented high amount of protein, however there was no statistically significant difference from 10th to 20th processing (P = 0.60). All instruments submitted to manual and/or automated cleaning did not present residual protein. It was possible to identify residue and biofilm into lumen of surgical instruments after 20 reprocessing. CONCLUSION: Experimental techniques to formation and evaluation of biofilm in surgical instruments manufactures in stainless steel were validated and 20 inappropriated cleaning processing were enough to buildup biofilm. Biofilm was formed within lumens of flexible drill bite cutter and depth gauge, after 20 processing despite the instruments were submitted to “gold standard” cleaning, also accumulation of protein on flexible drill bite cutters. Depth gauge lumen allowed accumulation of waste using manual cleaning followed by automation cleaning and manual cleaning allowed buildup residue on its external surface. Manual cleaning allowed accumulation residue on deep gauge. It was not possible to recover viable S. aureus in biofilm on instrumental surface, but it indicates that design of instruments evaluated is not safe to processing. It is presumed have risk ratio for aseptic loss of prostheses and infection related to healthcare, since they are instruments of difficult cleaning control and circulate in numerous healthcare facilites using different cleaning protocols. / INTRODUÇÃO: O medidor de profundidade e a fresa flexível são instrumentos cirúrgicos ortopédicos de conformação complexa e integram as caixas cirúrgicas fornecidas por distribuidores aos diferentes serviços de saúde. O desafio é garantir limpeza adequada, impedindo a formação de biofilmes nesses modelos de instrumental. Não existem estudos experimentais ou clínicos analisando o impacto de diferentes protocolos de limpeza na formação de biofilme nas superfícies desses modelos de instrumental. OBJETIVOS: Validar método laboratorial de formação de biofilme e análise em instrumento de aço inoxidável, avaliar a carga microbiana e determinar a formação de biofilme após contaminação laboratorial e processamento por múltiplos ciclos em instrumental cirúrgico de conformação complexa utilizado em cirurgias ortopédicas com implantes. MÉTODO: Estudo experimental realizado de novembro/2014 a março/2016, no laboratório da Universidade Macquarie, Sydney (AU). Validação do método: pinças halsted mosquito novas foram contaminadas em solução contendo S. aureus (ATCC 25923) e esterilizadas em vapor saturado sob pressão. As pinças foram separadas em três grupos segundo a limpeza: 1) enxágue, 2) limpeza manual e 3) limpeza manual seguida de automatizada. Após os 6°, 13° e 20° processamentos, três pinças de cada protocolo foram submetidas à análise de carga microbiana, proteína (Bicinchoninic Acid Assay) e análise visual por microscopia eletrônica de varredura. A mesma metodologia foi seguida no experimento com a fresa flexível e medidor de profundidade novos, sendo as análises realizadas após os 10° e 20° processamentos. RESULTADOS: Validação do método: Pinças submetidas aos protocolos 1 (controle positivo da limpeza) e 2 apresentaram biofilmes, e a pinça submetida ao protocolo 3 apresentou resíduo após 20 processamentos e não foram identificados micro-organismos nem proteína. Experimento com instrumental de conformação complexa: fresa flexível submetida ao protocolo 1 apresentou elevada quantidade de proteína com aumento de 1699µg de proteína do 10° para o 20° processamento (P=0,03). Medidor de profundidade submetido ao mesmo protocolo também apresentou elevada quantidade de proteína, não sendo significante a diferença entre o 10° e o 20° processamento (P=0,60). Todo instrumental submetido à limpeza manual e/ou automatizada não apresentou resíduo de proteína. Foi possível identificar resíduo nos três grupos de limpeza após 20 processamentos. CONCLUSÃO: Técnicas, para formação e avaliação de biofilme em instrumental cirúrgico fabricado em aço inoxidável, foram validadas, e 20 processamentos inadequados formam biofilmes. Houve formação de biofilmes nos lúmens da fresa flexível e no medidor de profundidade após 20 processamentos, mesmo utilizando o padrão ouro da limpeza, bem como acúmulo de proteína na fresa flexível ao longo dos processamentos. O lúmen do medidor de profundidade desmontável permitiu acúmulo de resíduos, mesmo usando limpeza manual seguida de automatizada. Limpeza manual permitiu o acúmulo de resíduos no medidor de profundidade. Não foi possível recuperar S. aureus viáveis no biofilme aderido à superfície de instrumental, porém sinaliza que o design do instrumental avaliado não é seguro para o processamento. Presume-se relação de risco para perda asséptica de próteses e infecção relacionada à assistência à saúde, pois são instrumental de difícil controle da limpeza e circulam em inúmeros serviços de saúdes com diferentes protocolos de limpeza.
24

Sustainable Public Procurement as a Driver of Change : The Case of Surgical Instruments

van den akker, Dennis, Wakim, Riad Samir January 2019 (has links)
Although Sustainable Public Procurement (SPP) is often seen as a powerful tool to drive sustainability across its supply chain, there is little available research in terms of how SPP actually influences its suppliers’ sustainability practices and what challenges are being faced during the process. In this study, we shed light on both issues by exploring SPP using Institutional and Power Dependence Theory in the context of the surgical instrument industry in Sweden. Methodologically, the study is grounded in an exploratory design and employs in-depth interviews with multiple stakeholders to gain a holistic understanding of the phenomena being studied. The study revealed that SPP mainly influences suppliers by requiring them to evaluate their own sustainability practices, engage in collaborative actions and make alterations when they fail to comply with the contractual terms.The most significant challenge resulted to be the lack of resources, resulting in the inability to perform sufficient follow-ups, engage in meaningful conversations with suppliers and procurers having to buy unsustainable products because of their tight budgets. Another major challenge was Sweden’s forerunner position when it comes to SPP on an international level, resulting in reluctancy on the part of international suppliers to alter their sustainability practices.
25

Perfil biodinâmico de entrada dos trocartes em cirurgias laparoscópicas / Biodynamic profile of entry of trocars in laparoscopic surgeries

Moreno, Danilo Galante 14 March 2019 (has links)
INTRODUÇÃO: A técnica laparoscópica tornou-se a via preferencial em grande parte dos procedimentos cirúrgicos, na tentativa de minimizar riscos e melhorar o pósoperatório. No entanto, o entusiasmo dos cirurgiões com a novas técnicas frequentemente omite uma avaliação clara das suas possíveis complicações. A laparoscopia pode oferecer alguns riscos tanto no acesso à cavidade abdominal (com trocartes sendo introduzidos muitas vezes às cegas), quanto na realização de todo o procedimento. Na literatura, poucos estudos compararam os diversos tipos de acesso e de trocartes, utilizando parâmetros objetivos e reprodutíveis do momento da punção. Nessa tese foram comparadas as diferenças no padrão biodinâmico de entrada de cinco diferentes trocartes,em modelos suínos. MÉTODOS: Foram utilizadas 11 porcas (fêmeas) e cinco tipos de trocartes (três marcas com lâmina - M1L, M2L, M3L e 2 sem lâmina - M4SL e M5SL). Todas as punções foram feitas pelo mesmo pesquisador e todos os trocartes eram novos no início do estudo. Realizada incisão bilateral a 4 cm da linha mediana do porco, endereçando toda a parede abdominal, desde as costelas (superiormente) até a crista ilíaca (inferiormente). Utilizado suporte metálico tracionando uma faixa mediana da parede abdominal do animal \"in vivo\" (posição supina). Desta forma, um espaço foi criado afastando a parede abdominal das vísceras e possibilitando a filmagem das punções. Para aferição da força na inserção foi desenvolvido um sensor de mão, ligado a um computador para aquisição dos dados. Avaliado força necessária para perfuração da aponeurose (F1) e do peritônio (F2). Utilizado uma câmera de alta resolução para captura de imagens durante a entrada dos trocartes e realizada análise comparativa da deformação da parede abdominal (Dd), do tempo (TLam) e distância (DLam) percorrida pela lâmina exposta para os cinco tipos de trocartes. Os sítios de punção foram predeterminados na linha mediana do suíno. Realizada análise uni e multivariada. RESULTADOS: Foram analisadas 180 punções, sendo 36 para cada um dos cinco modelos de trocartes. Comparando-se apenas trocartes com e sem lâminas, percebe-se maiores valores para os últimos quanto a força e deformação de parede (todos com p < 0,001). Comparando-se marca a marca temos: Dd (cm) - M1L (5,92) , M2L (5,85) e M3L (6,07) semelhantes entre si, menores que M4SL (8,33) e M5SL (8,15), semelhantes entre si; F1 e F2 (N) - M1L (5,73) e M2L (6,22) semelhantes entre si, menores que M3L (7,69), esse menor que M4SL (8,29) e M5SL (10,24), semelhantes entre si. DLam (cm) - não houve diferença estatística entre os trocartes (p=0,197); TLam (s) - M1L (0,5) e M2L (0,37) semelhantes entre si, menores que M3L (0,87). CONCLUSÕES: Trocartes com lâmina, em comparação aos sem lâmina, possuem menores forças e deformações em sua introdução. Os trocartes laminados cônicos e piramidais (M1L e M2L respectivamente) são semelhantes entre si em todos os parâmetros analisados. No entanto, esses dois tem menores deformações, força de inserção e tempo de lâmina expostos em comparação ao piramidal M3L. A análise da distância de lâmina exposta não mostrou diferença estatística entre os trocartes. Entre os trocartes sem lâmina, M5SL apresentou maiores forças de inserção e mesma deformação em comparação a M4SL / INTRODUCTION: Laparoscopic surgery has become a preference for most surgeons, proving to be versatile and applicable to several surgical procedures. However, the enthusiasm of surgeons with new techniques often omits a clear evaluation of their possible complications. Comparative studies of trocars, showing objective and reproducible parameters at the time of puncture, are still lacking in the literature. The objective of this study is to evaluate the biodinamic profile of entry of 5 different trocars in laparoscopic surgeries. METHODS: Using a porcine model, we evaluated the following characteristics in 11 pigs about the insertion of 5 types of trocars (3 bladed and 2 blunt): 1) the force necessary to push trocar through the abdominal wall aponeurosis (F1) and through the peritoneum (F2); 2) the amount of time (in seconds) in which the blade of the trocar is exposed within the peritoneal cavity; 3) the amount of deformity of the abdominal wall (in cm) prior to the blade of trocar cutting through the peritoneum; 4) the distance traveled by the blade within the peritoneal cavity (in cm). All punctures were made by the same researcher. The bilateral incision was performed at 4 cm of the pig\'s median line, addressing the entire abdominal wall, from the ribs (superiorly) to the iliac crest (inferiorly). Metallic support was used by traction of a median range of the abdominal wall of the animal \"in vivo\" (supine position). A space was created by pushing the abdominal wall away from the viscera and allowing the punctures to be filmed. To measure the insertion force was used a mechanical device designed for this, connected to a computer for data acquisition. A high-speed camera made the acquisition of the images. Puncture sites were predetermined at the midline of the pig. RESULTS: A total of 180 punches were analyzed, of which 36 were analyzed for each of the 5 trocar models. Greater deformations forces occurred in non-bladed compared to the bladed one (p < 0.001). Comparing the marks: Dd (cm) - M1L (5,92), M2L (5,85) and M3L (6,07) are similar to each other, smallers than M4SL (8,33) and M5SL (8,15), similar to each other; F1 e F2 (N) - M1L (5,73) and M2L (6,22) are similar to each other, smallers than M3L (7,69), and this smaller than M4SL (8,29) and M5SL (10,24), similar to each other. DLam (cm) - there is no diference between the all trocars (p=0,197); TLam (s) - M1L (0,5) and M2L (0,37) are similar to each other, smallers than M3L (0,87). CONCLUSIONS: The bladed trocars, compared to the non-bladed ones, have lower forces and deformations in their introduction. Conical (M1L) and pyramidal (M2L) trocars showed similar patterns of all analysed parameters. They have lower force and deformation, as well as time and distance of exposed blade in comparision of the pyramidal M3L. There is no diference in distance of exposed blade between the all bladed trocars. As for the non-bladed, the conical model (M5SL) required a greater deformation force than the pyramidal one (M4SL)
26

O impacto do uso de diferentes tipos de luvas e das mãos nuas na inspeção e preparo do instrumento cirúrgico limpo / The impact of the use of different kinds of gloves and bare hands when handling surgical instruments

Bruna, Camila Quartim de Moraes 17 March 2015 (has links)
Introdução: A inspeção e o acondicionamento dos instrumentais cirúrgicos limpos em caixas e bandejas, implicam na manipulação desses produtos. Na prática, é possível observar grande descompasso entre o cuidado dispensado a essa etapa, quando comparado ao rigor exigido para remoção completa de contaminantes por meio da limpeza. A falta de consenso quanto ao uso de luvas nessa etapa do processo chama a atenção e não se sabe se esse detalhe repercute na qualidade final do material quanto à segurança para o paciente cirúrgico. Objetivos: Determinar se há diferenças na resposta citotóxica relacionada ao uso de distintos tipos de luvas e das mãos nuas na inspeção e preparo do instrumental cirúrgico limpo e avaliar a carga microbiológica de instrumentais cirúrgicos preparados sem luvas e sua repercussão na esterilização. Método: Esta pesquisa realizou um experimento laboratorial com abordagem pragmática, utilizando cânulas de oftalmologia que foram manipuladas com diferentes tipos de luvas e com as mãos nuas. Posteriormente, o teste de citotoxicidade foi realizado por meio da difusão em ágar. Pinças anatômicas também fizeram parte da amostra para a análise exploratória microbiológica, após serem manipuladas sem luvas, e posteriormente, submetidas à avaliação de sua esterilidade, após autoclavação. Resultados: Nenhuma das amostras de cânulas de oftalmologia manipuladas por diferentes tipos de luvas e por mãos nuas apresentou efeito citotóxico.Todas as culturas microbiológicas das pinças anatômicas manipuladas sem luvas apresentaram crescimento de microrganismos aeróbios e anaeróbios, embora nenhum microrganismo tenha sido recuperado após a autoclavação. Conclusão: Não houve evidências de diferenças de resposta citotóxica relacionada ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas implica aumento dos custos do processo e na geração de resíduos, além do potencial risco alergênico ao látex. Esta pesquisa teve como relevância subsidiar a elaboração de protocolos para a etapa de preparo de instrumentais cirúrgicos limpos / Introduction: The aim of reprocessing surgical instruments is to provide instruments that are clean, in good working condition and ultimately sterile thus ensuring patient safety. During instrument there is no agreement about the necessity for glove use. Therefore, there is little reason for employees to wear gloves to protect themselves from possible residual contaminants on cleaned instruments that had previously been used during clean or sterile surgery. On the other hand, the use of the gloves to handle surgical instruments during preparation increases medical waste, increases medical costs and could increase the prevalence of glove allergies in staff. Aim: In this study we investigated the risk posed to patients from staff wearing different types of gloves or no gloves to prepare surgical kits. Method: Five cleaned ophtalmic cannulas were handled using different kinds of gloves and with bare hands, package and steam sterilized. An in vitro cytotoxicity test was conducted, using the agar diffusion test. Microbiological tests were conducted as well, in samples handled with bare hands. Results: All test samples showed the same mild reactivity (grade 2) indicating that handling instruments with gloves or bare hands did not leave any residual toxic products on the instrument surface. Conclusion: We found no difference in the iatrogenic risk to patients of either increased toxicity or increased risk of microbial contamination if surgical instruments are prepared with or without gloves. However, the use of gloves has some inherent disadvantages, such as the risk of latex sensitization of the workers and increased medical costs due to purchase and waste disposal
27

O impacto do uso de diferentes tipos de luvas e das mãos nuas na inspeção e preparo do instrumento cirúrgico limpo / The impact of the use of different kinds of gloves and bare hands when handling surgical instruments

Camila Quartim de Moraes Bruna 17 March 2015 (has links)
Introdução: A inspeção e o acondicionamento dos instrumentais cirúrgicos limpos em caixas e bandejas, implicam na manipulação desses produtos. Na prática, é possível observar grande descompasso entre o cuidado dispensado a essa etapa, quando comparado ao rigor exigido para remoção completa de contaminantes por meio da limpeza. A falta de consenso quanto ao uso de luvas nessa etapa do processo chama a atenção e não se sabe se esse detalhe repercute na qualidade final do material quanto à segurança para o paciente cirúrgico. Objetivos: Determinar se há diferenças na resposta citotóxica relacionada ao uso de distintos tipos de luvas e das mãos nuas na inspeção e preparo do instrumental cirúrgico limpo e avaliar a carga microbiológica de instrumentais cirúrgicos preparados sem luvas e sua repercussão na esterilização. Método: Esta pesquisa realizou um experimento laboratorial com abordagem pragmática, utilizando cânulas de oftalmologia que foram manipuladas com diferentes tipos de luvas e com as mãos nuas. Posteriormente, o teste de citotoxicidade foi realizado por meio da difusão em ágar. Pinças anatômicas também fizeram parte da amostra para a análise exploratória microbiológica, após serem manipuladas sem luvas, e posteriormente, submetidas à avaliação de sua esterilidade, após autoclavação. Resultados: Nenhuma das amostras de cânulas de oftalmologia manipuladas por diferentes tipos de luvas e por mãos nuas apresentou efeito citotóxico.Todas as culturas microbiológicas das pinças anatômicas manipuladas sem luvas apresentaram crescimento de microrganismos aeróbios e anaeróbios, embora nenhum microrganismo tenha sido recuperado após a autoclavação. Conclusão: Não houve evidências de diferenças de resposta citotóxica relacionada ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas implica aumento dos custos do processo e na geração de resíduos, além do potencial risco alergênico ao látex. Esta pesquisa teve como relevância subsidiar a elaboração de protocolos para a etapa de preparo de instrumentais cirúrgicos limpos / Introduction: The aim of reprocessing surgical instruments is to provide instruments that are clean, in good working condition and ultimately sterile thus ensuring patient safety. During instrument there is no agreement about the necessity for glove use. Therefore, there is little reason for employees to wear gloves to protect themselves from possible residual contaminants on cleaned instruments that had previously been used during clean or sterile surgery. On the other hand, the use of the gloves to handle surgical instruments during preparation increases medical waste, increases medical costs and could increase the prevalence of glove allergies in staff. Aim: In this study we investigated the risk posed to patients from staff wearing different types of gloves or no gloves to prepare surgical kits. Method: Five cleaned ophtalmic cannulas were handled using different kinds of gloves and with bare hands, package and steam sterilized. An in vitro cytotoxicity test was conducted, using the agar diffusion test. Microbiological tests were conducted as well, in samples handled with bare hands. Results: All test samples showed the same mild reactivity (grade 2) indicating that handling instruments with gloves or bare hands did not leave any residual toxic products on the instrument surface. Conclusion: We found no difference in the iatrogenic risk to patients of either increased toxicity or increased risk of microbial contamination if surgical instruments are prepared with or without gloves. However, the use of gloves has some inherent disadvantages, such as the risk of latex sensitization of the workers and increased medical costs due to purchase and waste disposal
28

Carga microbiana de trocartes reprocessaveis apos laparoscopias ginecologicas / Microbial load of reusables trocars after gynecology laparoscopy

Vilas-Boas, Vanessa Aparecida, 1981- 14 August 2018 (has links)
Orientador: Maria Isabel Pedreira de Freitas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-14T15:03:05Z (GMT). No. of bitstreams: 1 Vilas-Boas_VanessaAparecida_M.pdf: 29367721 bytes, checksum: c5b64e8b977736f8ec3c05b44d7edf96 (MD5) Previous issue date: 2009 / Resumo: A transmissão de infecções hospitalares está relacionada à sobrevivência de microrganismos nas superfícies ambientais e no instrumental cirúrgico. Nos últimos anos, o Brasil tem se deparado com um cenário disperso em relação à validação do processo de limpeza e esterilização de instrumentos cirúrgicos utilizados em acessos minimamente invasivos, principalmente os procedimentos realizados por vídeo. Para implantação de medidas eficazes no reprocessamento é necessário saber como está o material em termos de contaminação e verificar se a carga microbiana trazida por esse instrumental é superior ao desafio microbiano imposto pelos indicadores biológicos. Deste modo, espera-se que a análise quanti-qualitativa dos microrganismos presentes em instrumentos cirúrgicos laparoscópicos após o uso clínico possa nortear a tomada de decisão pelos profissionais de saúde a contribuir para a melhoria do processo de trabalho visando à segurança do paciente. Objetivo: Identificar a carga microbiana presente nos trocartes reprocessáveis de 5 mm e 10 mm, usados para realização de laparoscopias ginecológicas. Material e Método: Tratase de um estudo exploratório descritivo. Um total de 57 trocartes de 5 mm e 10 mm de diâmetro foi recolhido na sala de operação, imediatamente após o uso na paciente, sendo acondicionados separadamente em embalagem plástica esterilizada, acrescentado 250 ml de água destilada estéril, lacrado e agitado a 120 rpm por 10 minutos. Com técnica asséptica, os trocartes foram retirados da embalagem e o lavado obtido foi levado ao Laboratório de Microbiologia onde foi filtrado por um filtro contendo uma membrana de celulose de 0,22 µm que foi colocada em placa Petri contendo ágar sangue. As placas foram incubadas em estufa e encaminhadas para contagem de microrganismos, expressa em unidades formadoras de colônias (UFC) e identificação seguindo técnicas laboratoriais padrão. Resultados: Em 52,63% dos trocartes não foram recuperados microrganismos viáveis, 45,62% apresentaram crescimento microbiano de 1-100 UFC, e somente em 1,75% dos trocartes recuperou-se carga microbiana maior que 100 UFC. Os microrganismos mais frequentemente isolados foram o Staphylococcus coagulase negativo (28%) e o Bacillus sp (22%). Outros microrganismos de importância clínica conhecida incluíram: Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli e Aeromonas hidrophyla. Discussão: O estudo demonstrou que o desafio microbiano enfrentado pelos Centros de Material e Esterilização é baixo quando comparado com o desafio imposto pelos indicadores biológicos que monitoram os ciclos de esterilização, correspondentes a 106 UFC de bacilos esporulados. Além disso, apesar dos trocartes, utilizados em laparoscopias ginecológicas consideradas limpas, apresentarem baixa carga microbiana, não se pode inferir que os riscos de complicações infecciosas sejam mínimos. Conclusão: Os trocartes aparoscópicos utilizados em laparoscopias ginecológicas limpas apresentaram carga microbiana baixa (?10 a ?102 UFC) / Abstract: The transmission of hospital infections is related to survival of microorganisms on environmental surfaces and surgical instruments. In recent years, Brazil has been facing a scenario scattered on the validation of cleaning and sterilizing surgical instruments used in minimally invasive procedures performed primarily for video. For implantation of effective reprocessing and need to know how this stuff in terms of contamination and whether the microbial load brought by this instrument is superior to the microbial challenge imposed by biological indicators. Thus, it is expected that the quantitative and qualitative analysis of microorganisms in laparoscopic surgical instruments after use to guide the surgical decision-making by health professionals to contribute to the improvement of the work aimed at patient safety. Objective: To identify the microbial load present in reprocessable trocars of 5 mm and 10 mm, used for realization of gynecological laparoscopy. Material and Method: This is an exploratory descriptive study. A total of 57 trocars of 5 mm and 10 mm in diameter was collected in the operating room, immediately after use in the patient, and packed separately in sterile plastic bag, added 250 ml of sterile distilled water, sealed and shaken at 120 rpm for 10 minutes. With aseptic technique, the trocars were removed from the pack and washed obtained was taken to the microbiology laboratory where it was filtered through a filter containing a cellulose membrane of 0,22µm which was placed in Petri dishes containing blood agar. The plates were incubated in and sent to the microorganism counts expressed as colony forming units (CFU) and identification following standard laboratory techniques. Results: In 52.63% of the trocars were not recovered microorganisms, 45.62% had microbial growth of 1-100 UFC, and only 1.75% of the trocars recovered microbial counts greater than 100 CFU. The microorganisms most frequently isolated were coagulase negative Staphylococcus (28%) and Bacillus sp (22%). Other organisms known clinically important included: Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli and Aeromonas hidrophyla. Discuss: The study showed that the microbial challenge faced by the Centers for Sterilization is low compared with the challenge posed by biological indicators that monitor the sterilization cycle, corresponding to 106 CFU of sporulated bacilli. Moreover, despite the trocars used during gynecological laparoscopy considered clean, have lower microbial load, one can not infer that the risk of infectious complications are minimal. Conclusion: The laparoscopic trocars used during gynecological laparoscopy showed microbial clean low (?10 a ?102 UFC) / Mestrado / Enfermagem e Trabalho / Mestre em Enfermagem
29

Avaliação da incidência de micro trincas dentinárias após instrumentação reciprocante e rotatória /

Melo, Allana Agnes Pereira de. January 2019 (has links)
Orientador: Eduardo Galera da Silva / Banca: Claudio Hideki Kubo / Banca: Rodrigo Máximo de Araújo / Resumo: Para que o tratamento endodôntico tenha sucesso, buscam-se meios de realizar uma limpeza eficiente e modelagem adequada do canal radicular. No entanto, na prática clínica, alguns problemas podem ser encontrados durante a instrumentação, sendo um deles a formação de micro trincas e linhas de fratura, que podem evoluir após o estresse causado pelas forças oclusais e resultar em uma fratura completa da raiz. O presente estudo teve por objetivo avaliar a incidência de micro trincas dentinárias em 48 incisivos inferiores humanos extraídos, utilizando estereomicroscópio e Tomografia Computadorizada de Feixe Cônico (TCFC), após o preparo do canal radicular com o sistema ProDesign S (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brasil) em movimento rotatório e reciprocante, o sistema ProDesign R (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brasil) em movimento reciprocante e o sistema Reciproc (VDW, Munich, Germany) em movimento reciprocante. Além disso, buscouse analisar a superfície dos instrumentos quando sem uso, após o primeiro uso, e sucessivamente até o terceiro uso, através de estereomicroscópio e microscopia eletrônica de varredura. Os resultados foram submetidos à análise estatística por meio da Prova de Friedman. Houve formação de micro trincas dentinárias em todos os grupos avaliados em Estereomicroscópio após o preparo do canal radicular utilizando o sistema ProDesign S em movimento rotatório e reciprocante, o sistema ProDesign R em movimento reciprocant... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: So that the endodontic treatment is successful, means to achieve an efficient cleaning and proper modeling of root canal are sought. However, in clinical practice, some problems may be encountered during the instrumentation, one of them being the formation of micro cracks and lines of fracture, which may evolve after the stress caused by occlusal forces and result in a complete root fracture. The objective of this study is to evaluate the incidence of dentin micro cracks in 48 extracted human incisors using stereomicroscope and cone beam computed tomography (TCFC), after the root canal preparation with ProDesign S system (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil), in rotatory and reciprocating movement, ProDesign R system (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil) in reciprocating movement and Reciproc system (VDW, Munich, Germany) in reciprocating movement. In addition, it was aimed to analyze the instruments surface when without use, after first use, and successively until the third use, through a stereomicroscope and scanning electron microscopy. The results will be subjected to statistical analysis by means of the Friedman test. Dentin micro cracks were formed in all groups evaluated in a stereomicroscope after root canal preparation using the ProDesign S system in rotating and reciprocating motion, the ProDesign R system in reciprocating motion and the Reciproc system in reciprocating motion; but without statistically significant dif... (Complete abstract click electronic access below) / Mestre
30

Surgical Instruments based on flexible micro-electronics

Rivkin, Boris 15 December 2022 (has links)
This dissertation explores strategies to create micro-scale tools with integrated electronic and mechanical functionalities. Recently developed approaches to control the shape of flexible micro-structures are employed to fabricate micro-electronic instruments that embed components for sensing and actuation, aiming to expand the toolkit of minimally invasive surgery. This thesis proposes two distinct types of devices that might expand the boundaries of modern surgical interventions and enable new bio-medical applications. First, an electronically integrated micro-catheter is developed. Electronic components for sensing and actuation are embedded into the catheter wall through an alternative fabrication paradigm that takes advantage of a self-rolling polymeric thin-film system. With a diameter of only 0.1 mm, the catheter is capable of delivering fluids in a highly targeted fashion, comprises actuated opposing digits for the efficient manipulation of microscopic objects, and a magnetic sensor for navigation. Employing a specially conceived approach for position tracking, navigation with a high resolution below 0.1 mm is achieved. The fundamental functionalities and mechanical properties of this instrument are evaluated in artificial model environments and ex vivo tissues. The second development explores reshapeable micro-electronic devices. These systems integrate conductive polymer actuators and strain or magnetic sensors to adjust their shape through feedback-driven closed loop control and mechanically interact with their environment. Due to their inherent flexibility and integrated sensory capabilities, these devices are well suited to interface with and manipulate sensitive biological tissues, as demonstrated with an ex vivo nerve bundle, and may facilitate new interventions in neural surgery.:List of Abbreviations 1 Introduction 1.1 Motivation 1.2 Objectives and structure of this dissertation 2 Background 2.1 Tools for minimally invasive surgery 2.1.1 Catheters 2.1.2 Tools for robotic micro-surgery 2.1.3 Flexible electronics for smart surgical tools 2.2 Platforms for shapeable electronics 2.2.1 Shapeable polymer composites 2.2.2 Shapeable electronics 2.2.3 Soft actuators and manipulators 2.3 Sensors for position and shape feedback 2.3.1 Magnetic sensors for position and orientation measurements 2.3.2 Strain gauge sensors 3 Materials and Methods 3.1 Materials for shapeable electronics 3.1.1 Metal-organic sacrificial layer 3.1.2 Polyimide as reinforcing material 3.1.3 Swelling hydrogel for self assembly 3.1.4 Polypyrrole for flexible micro actuators 3.2 Device fabrication techniques 3.2.1 Photolithography 3.2.2 Electron beam deposition 3.2.3 Sputter deposition 3.2.4 Atomic layer deposition 3.2.5 Electro-polymerization of polypyrrole 3.3 Device characterization techniques 3.3.1 Kerr magnetometry 3.3.2 Electro-magnetic characterization of sensors 3.3.3 Electro-chemical analysis of polypyrrole 3.3.4 Preparation of model environments and materials 3.4 Sensor signal evaluation and processing 3.4.1 Signal processing 3.4.2 Cross correlation for phase analysis 3.4.3 PID feedback control 4 Electronically Integrated Self Assembled Micro Catheters 4.1 Design and Fabrication 4.1.1 Fabrication and self assembly 4.1.2 Features and design considerations 4.1.3 Electronic and fluidic connections 4.2 Integrated features and functionalities 4.2.1 Fluidic transport 4.2.2 Bending stability 4.2.3 Actuated micro manipulator 4.3 Magnetic position tracking 4.3.1 Integrated magnetic sensor 4.3.2 Position control with sensor feedback 4.3.3 Introduction of magnetic phase encoded tracking 4.3.4 Experimental realization 4.3.5 Simultaneous magnetic and ultrasound tracking 4.3.6 Discussion, limitations, and perspectives 5 Reshapeable Micro Electronic Devices 5.1 Design and fabrication 5.1.1 Estimation of optimal fabrication parameters 5.1.2 Device Fabrication 5.1.3 Control electronics and software 5.2 Performance of Actuators 5.2.1 Blocking force, speed, and durability 5.2.2 Curvature 5.3 Orientation control with magnetic sensors 5.3.1 Magnetic sensors on actuated device 5.3.2 Reference magnetic field 5.3.3 Feedback control 5.4 Shape control with integrated strain sensors 5.4.1 Strain gauge curvature sensors 5.4.2 Feedback control 5.4.3 Obstacle detection 5.5 Heterogenous integration with active electronics 5.5.1 Fabrication and properties of active matrices 5.5.2 Fabrication and operation of PPy actuators 5.5.3 Site selective actuation 6 Discussion and Outlook 6.1 Integrated self assembled catheters 6.1.1 Outlook 6.2 Reshapeable micro electronic devices 6.2.1 Outlook 7 Conclusion Appendix A1 Processing parameters for polymer stack layers A2 Derivation of magnetic phase profile in 3D Bibliography List of Figures and Tables Acknowledgements Theses List of Publications

Page generated in 0.0927 seconds