• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 144
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 146
  • 85
  • 64
  • 63
  • 49
  • 47
  • 44
  • 40
  • 35
  • 34
  • 29
  • 27
  • 27
  • 27
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

"Efeito tardio do ruído na audição e na qualidade do sono em indivíduos expostos a níveis elevados" / Delayed Effect of Elevated Noise Levels on Hearing and Sleep

Ana Lúcia Rios 24 February 2003 (has links)
Nos últimos vinte anos, os estudos sobre os efeitos do ruído na audição e conseqüente qualidade de vida do ser humano ganharam grande impulso, evidenciando sua importância. O propósito do presente estudo foi verificar o efeito do ruído persistente, decorrente das condições de trabalho, sobre a qualidade de vida, relativamente às repercussões sobre a audição e a qualidade do sono. Neste sentido visou contribuir para a valorização dos prejuízos do ruído excessivo e sistemático sobre a saúde. Foram estudados 20 trabalhadores do sexo masculino, da Seção de Engenharia do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto (HCFMRP-USP), com idade entre 33 e 50 anos, expostos a ruído ambiental maior ou igual a 85 dB, em jornada de oito horas de trabalho diário, há pelo menos oito anos; sem alterações anatômicas de orelha externa/média e de vias aéreas superiores. Outros 20 trabalhadores da Seção de Atividades Complementares do mesmo hospital na mesma faixa etária e mesmas características físicas, sócio-econômico-culturais, expostos ao ruído ambiental habitual inferior a 85 dB na jornada de trabalho de 8 horas diárias, compuseram um grupo controle. Os dados de audiometria tonal limiar e imitanciometria foram correlacionados com a qualidade do sono observada através da polissonografia e com parâmetros clínicos gerais de saúde. Com os resultados dos testes de comparação aplicados a idade, estatura, peso, índice de massa corporal, circunferência do pescoço, cintura e quadril e indicadores do estado sócio-econômico-cultural obtidos em entrevista, verificamos que as amostras foram semelhantes nestes aspectos. A análise estatística da audiometria e imitanciometria, nos dois grupos, feita pelo teste exato de Fischer revelou perda auditiva leve e moderada, do tipo PAIR, significante (p < 0,001) no G1. O sono dos indivíduos dos dois grupos apresentou anormalidades nas medidas de continuidade do sono revelando sono de má qualidade. Dos 40 indivíduos, treze (32,5 %) apresentaram distúrbio respiratório do sono, dez dos quais tinham sonolência pela Escala de Epworth; doze outros (30 %) tinham sonolência sem distúrbio respiratório do sono. Os indicadores da quantidade de sono revelaram-se normais. As comparações mostraram que o sono dos dois grupos é igual, quando analisado pelo teste de Mann – Whitney para dados independentes. Análise de contingência entre sono alterado e perda auditiva revelou ausência de interrelação (p = 0,4316). Concluimos que a permanência prolongada sob ruído ambiental superior aos níveis considerados seguros foi suficiente para produzir danos auditivos detectáveis laboratorialmente através dos testes usuais e que não há razão para crer que a má qualidade do sono do cidadão comum guarde relação com a convivência diurna em ambientes ruidosos. / In the last twenty years, the studies on the effect of noise in the hearing and consequently in the quality of life of the human have earned great impulse, evidencing its importance. The purpose of the present study was to verify the effect of persistent noise, occasioned by work conditions, on the quality of life, concerned to the repercussions on the hearing and on the quality of sleep. In this direction, this study aimed at contributing to the awareness of damages caused by extreme and systematic noise on health. Twenty male workers, from the Engineering Section of the Hospital of Clinics of the Faculty of Medicine of Ribeirão Preto (HCFMRP-USP), with ages between 33 and 50 years old, exposed to environmental noise louder or equal 85 dB, on a daily eight-hour working week, for at least eight years, with no anatomical alterations of the extern/medium ear and upper airways; were studied. Other twenty workers from the Complementary Activities Section of the same hospital, in the same age range and equal physical, social-economical-cultural characteristics, exposed to usual environmental noise (lower than 85 dB), on a daily eight-hour working week, composed a control group. The data from the pure tone audiometry and the impedance measurements were correlated with the quality of sleep observed through the polysomnography and with the general clinical health parameters. The results showed that two groups had similar physical social-economic and cultural aspects, when comparison tests where applied to age, height, weight, body mass index, size of the neck, wrist and hips and socio-economic and cultural markers obtained by clinical interview. Statistical analysis of audiometria e imitanciometria by Fischer’s test has shown significant (p = 0,001) mild and moderate hearing loss in G1. The majority of the subjects had bad sleep quality as shown by analysis of sleep disruption markers. The 40 subjects, thirteen (32,5 %) have had sleep disordered breathing ten of whom had day-time sleepiness as measured by Epworth scale; twelve other subjects (30 %) had day-time sleepiness without sleep disordered breathing. The sleep amount markers where normal. At statistical analysis by Mann-Whitney test the sleep of the two groups was equal. Analysis of contingency between altered sleep and hearing loss has shown no correlation (p = 0,4316). Conclusion long stay under noisy condition was enough to produce hearing loss detectable through usual laboratorial tests the there is no reason to believe that sleep of bad quality of ordinary people keep relation with diurnal stay under noisy condition.
32

Respostas auditivas de estado estável em crianças de 6 a 48 meses com audição normal

Glória Apolônio dos Santos, Alexsandra 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T22:56:20Z (GMT). No. of bitstreams: 2 arquivo1280_1.pdf: 3928149 bytes, checksum: 5d8011de1e7ed97100edc1ddfde66b7f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / A utilização de métodos de avaliação que possam refletir uma estimativa abrangente e confiável da audição vem assumindo grande importância para o pleno desenvolvimento infantil, nos âmbitos, social, cognitivo e lingüístico. A resposta auditiva de estado estável é um procedimento eletrofisiológico que possibilita avaliar, ao mesmo tempo, limiares auditivos com especificidade, por frequências e por orelha. O objetivo deste estudo foi verificar como os limiares eletrofisiológicos obtidos por essa técnica podem estimar os níveis mínimos de resposta comportamentais obtidos pelo padrão ouro, a audiometria de reforço visual, em crianças com audição normal, averiguando assim a aplicabilidade clínica da resposta auditiva de estado estável na avaliação audiológica infantil. Foram avaliadas 65 crianças de ambos os sexos (35 crianças do sexo masculino e 30 do sexo feminino) com uma faixa etária compreendida entre 6 e 48 meses. Obtiveram-se as respostas auditivas de toda amostra mediante a técnica da resposta auditiva de estado estável em múltiplas frequências de forma dicótica, e da técnica da audiometria de reforço visual em campo livre (50 crianças) ou com fones supra-aurais do tipo TDH-39 (15 crianças). Foram pesquisadas as frequências de 500, 1000, 2000 e 4000 Hz em ambos os métodos de avaliação. As respostas auditivas foram analisadas para calcular suas correlações e outras variáveis. Os resultados encontrados neste estudo demonstraram que as amplitudes da resposta auditiva de estado estável não apresentaram diferença estatística significante entre o sexo feminino e sexo masculino. Também não foram encontradas diferenças significantes, para os limiares da resposta auditiva de estado estável e para os níveis mínimos de resposta da audiometria de reforço visual, com relação à idade e ao sexo. Em média, foram observados limiares eletrofisiológicos maiores que os níveis mínimos de resposta comportamentais, e uma tendência das diferenças serem maior para as crianças que utilizaram fones na audiometria de reforço visual. Ao utilizar os limites de concordância estabelecidos, foi possível verificar após a correção do viés, uma discrepância entre a resposta auditiva de estado estável e a audiometria de reforço visual em campo livre de até ± 23 dB NA, e de até ± 30 dB NA entre a resposta auditiva de estado estável e a audiometria de reforço visual realizada com fones. Esta diferença diminui para frequências agudas. A duração média para a realização da pesquisa da resposta auditiva de estado estável foi de 44 minutos, com o tempo mínimo de 15 minutos e o tempo máximo de 80 minutos. Os achados sugerem que a utilização da resposta auditiva de estado estável, como instrumento para se adquirir limiares auditivos, é viável em lactentes e crianças pequenas, contribuindo para a caracterização da configuração audiométrica. Recomenda-se, entretanto, a realização de novos estudos que visem o estabelecimento de critérios mínimos necessários para o planejamento e aplicação de protocolos com fins de padronização, contribuindo com a validação diagnóstica
33

LIMIAR TONAL DE AUDIBILIDADE DE TRANSPLANTADOS HEPÁTICOS EM USO DE DIFERENTES PROTOCOLOS DE IMUNOSSUPRESSÃO / PURE-TONE THRESHOLD OF AUDIBILITY OF LIVER TRANSPLANT PATIENTS USING DIFFERENT IMMUNOSUPPRESSION PROTOCOLS

Corrêa, Maria Elena Fortes Machado 28 January 2005 (has links)
Many are the problems already documented in scientific literature that can derive from immunosuppression, such as: infections, neurologic complications, systemic arterial hypertension, renal dysfunction, diabetes, bone disease, obesity, among others. Regarding hearing, there are reports in international scientific literature that associate change in the pure tone threshold of audibility to immunosuppressants. In the use of Csa, there is interaction with erythromicin and a case report of hearing loss associated with FK506. FK506 is a macrolide just like erythromycin, of which reports about sensorineural hearing loss have been described in literature for about three decades. Clinical observation of gross hearing alterations in patients subjected to orthotopic liver transplant has led to the interest in studying the auditory acuity of liver transplant patients (TxH), since in domestic literature there are no studies related with hearing in that population. The aim of this research was to verify the potential effects associated with hearing in liver transplant patients and compare the potential changes in the pure tone threshold stemming from the use of cyclosporin (Csa) and tacrolimus (FK506). The subjects were assessed by liminal pure tone audiometry for pure tone thresholds of audibility in 84 ears of 42 patients, before and after orthotopic liver transplant. The patients were divided in two groups, cyclosporin (Csa n=18) and tacrolimus (FK n=24). The statistic analysis was carried out through application of non-parametric tests and use of occupational audiology criteria. The results pointed out to a statistically significant change in pure-tone threshold, particularly in high frequencies, in orthotopic liver transplant. Csa and FK506 were assumed to have noxious effects on the inner ear of these patients. Other results showed a greater significant change in the pure-tone threshold, between the right and left ears, in high frequencies, in group FK. The analyses undertaken, from an occupational perspective, confirmed the statistic data that pointed out to a trend of change in the puretone threshold in group FK. It was concluded that: liver transplant patients showed a worse pure-tone threshold after orthotopic liver transplant; the ones using tacrolimus showed more accentuated losses than those using cyclosporin; the worsening in the pure-tone threshold of audibility is more accentuated in high frequencies; the ones using tacrolimus had a loss in the pure-tone threshold in both high and low frequencies. The effects of a worsened pure-tone threshold may be multifactorial, since these patients show more co-morbidities and, thus, are subjected to several drug treatments, being exposed to the adverse effects and side effects of the drugs used. It´s underscored, however, that in this study the patients served as witnesses to themselves before and after the orthotopic liver transplant. Further studies are suggested so that the variables can be sorted with the purpose of characterizing this population in order to institute a phonoaudiological counseling. / São muitos os problemas, já documentados na literatura científica, que podem decorrer da imunossupressão, tais como: infecções, complicações neurológicas, hipertensão arterial sistêmica, disfunção renal, diabete, doença óssea, obesidade, entre outros. Em relação à audição, há relatos na literatura científica internacional, que associam a alteração no limiar tonal de audibilidade aos imunossupressores. No uso da Csa há interação com a eritromicina e relato de um caso de perda auditiva associada com o FK506. O FK506 é um macrolídeo assim como a eritromicina cujos relatos a respeito de perda auditiva sensorioneural, são descritos na literatura há cerca de três décadas. A observação clínica de alterações grosseiras da audição, em pacientes submetidos ao transplante ortotópico de fígado (TOF), despertou o interesse por estudar a acuidade auditiva dos transplantados hepáticos (TxH), uma vez que, na literatura nacional, inexistem trabalhos relacionados à audição com esta população. O Objetivo desta pesquisa foi verificar os possíveis efeitos associados à audição em TxH e comparar possíveis alterações no limiar tonal de audibilidade (LTA) decorrentes do uso de ciclosporina (Csa) e do uso do tacrolimus (FK506). Os indivíduos foram avaliados por meio da audiometria tonal liminar para pesquisa dos limiares tonais de audibilidade (LTA) em 84 orelhas de 42 pacientes, antes e depois do TOF. Os pacientes foram divididos em dois grupos, ciclosporina (Csa n=18) e tacrolimus (FK n=24). A análise estatística foi realizada por meio da aplicação de Testes Não Paramétricos, e da utilização de critérios da audiologia ocupacional. Os resultados apontaram alteração no LTA estatisticamente significativa, em especial, nas freqüências altas, no TOF. Supõe-se que a Csa e o FK506 possam ter efeitos nocivos sobre a orelha interna desses pacientes. Outros resultados mostraram significativa alteração no LTA, entre a OD e OE, em freqüências altas, mais no Grupo FK. As análises realizadas, sob a ótica ocupacional, confirmaram os dados estatísticos, que apontaram uma tendência de alteração do LTA no Grupo FK. Concluiuse que: os pacientes transplantados hepáticos apresentam piora no LTA após o TOF; os que usam tacrolimus apresentam perdas mais acentuadas do que os da ciclosporina; a piora do LTA é mais acentuada nas freqüências altas; os que usam tacrolimus têm perda no LTA nas freqüências altas e baixas. Os efeitos de piora no LTA podem ser multifatoriais, pois esses pacientes apresentam muitas co-morbidades e, portanto, inúmeros tratamentos medicamentosos, expondo-se aos efeitos adversos ou reações colaterais das drogas utilizadas. Salienta-se, entretanto, que nesse estudo, os pacientes são testemunhos de si próprios, no pré e no pós TOF. Sugere-se mais pesquisas que possam separar as variáveis, no intuito de caracterizar essa população, para que se possa instituir aconselhamento fonoaudiológico.
34

Achados dos potenciais evocados auditivos de estado estavel em crianças ouvintes e crianças portadoras de deficiência auditiva neurossensorial

Calil, Daniela Bortoloti 29 March 2006 (has links)
Made available in DSpace on 2016-04-27T18:12:11Z (GMT). No. of bitstreams: 1 DANIELA BORTOLOTI CALIL.pdf: 2150975 bytes, checksum: 6eaccd0f12d1b70e0eb9ca98f9a3b284 (MD5) Previous issue date: 2006-03-29 / The Auditory Steady State Response (ASSR) is a technique of objective evaluation of the hearing and can be done using some frequencies in both ears at the same time. The method consists on modulating the amplitude of each stimulation with a different frequency and presenting them simultaneously. Objective: Describe the findings of the ASSR for children with normal hearing and children with sensorineural hearing loss, in the frequencies of 500, 1000, 2000 and 4000 Hz, simultaneously. Method: Fourteen children with normal hearing, aging from 2 to 19 months; and seven children with moderate to profound sensorineural hearing loss, aging from 3 to 35 months were evaluated using ASSR evoked by multiple simultaneous stimuli with frequencies at 500, 1000, 2000 and 4000 Hz and modulation between 77 and 103 Hz in both ears. Results: the threshold response observed ASSR in Children with normal hearing was 6 to 17,2 dBNAcg, there was no significant difference observed between the frequencies. Children with sensorineural hearing loss, the findings of the ASSR showed a strong correlation with the results of the behavior audiometry. Conclusions: The ASSR is capable of showing audiometric status, specifying the degree and configuration of the hearing loss. It is possible to get responses in the ASSR even when the ABR is absent. The technique of the ASSR must be included in the clinical routine of children s hearing thresholds / Introdução: O potencial evocado auditivo de estado estável (PEAEST) é uma técnica de avaliação objetiva da audição e pode ser realizada em várias freqüências em ambas as orelhas ao mesmo tempo. O método consiste em se modular a amplitude de cada estímulo com uma freqüência diferente e apresenta-los simultaneamente. No domínio da freqüência, a resposta a cada tom aparece na freqüência em que cada estímulo foi modulado. Objetivo: Descrever os achados do Potencial Evocado Auditivo de Estado Estável para crianças ouvintes e crianças portadoras de deficiência auditiva, nas freqüências de 500, 1000, 2000 e 4000 Hz, bilateralmente. Método: 14 crianças ouvintes, com idades entre 2 e 19 meses; 7 crianças portadoras de deficiência auditiva neurossensorial de grau moderado a profundo com idades entre 3 e 35meses. Foram pesquisadas as freqüências de 500, 1000, 2000 e 4000 Hz com estímulos múltiplos simultâneos, com taxas de modulações entre 77 e 103 Hz, binauralmente. Resultados: nas crianças ouvintes as médias dos níveis de respostas do PEAEST observadas foram de 6 a 17.2 dBNAcg. Não houve diferença significativa entre as freqüências. Para as crianças portadoras de deficiência auditiva neurossensorial, os achados do PEAEST mostraram forte correlação com os resultados da audiometria comportamental. Conclusões: O PEAEST é capaz de predizer o grau e a configuração do status audiométrico. É possível obter respostas no PEAEST mesmo quando o PEATE está ausente. A técnica do PEAEST deve ser inclusa na rotina clinica da avaliação audiológica infantil
35

Mascaramento clínico: limiares auditivos pelos métodos Platô e Otimizado

Fernandes, Kelly Cristina de Souza 09 October 2007 (has links)
Made available in DSpace on 2016-04-27T18:12:24Z (GMT). No. of bitstreams: 1 Kelly Cristina de Souza Fernandes.pdf: 272473 bytes, checksum: fd1b99ff0dcaf5e12bdb0ad1b9c2912e (MD5) Previous issue date: 2007-10-09 / INTRODUCTION: Many situations may difficult the obtaining of thresholds for each ear, separately, in pure tone audiometry, demanding the use of masking. The plateau method, developed by Hood (1960) has being the most utilized for more than four decades. Nevertheless, Turner (2004) has suggested a masking protocol with a different method, called optimized, which could replace the previous one with efficacy in specific cases. PURPOSE: To verify if there is a difference among air and bone conduction hearing thresholds, using the two clinical masking methods: plateau and optimized. METHOD: Forty individuals aged from 15 to 65 years old, with either unilateral or bilateral hearing losses, considering unilateral, bilateral, symmetrical and just bone, proposed by Turner s classification, have participated of this study. They underwent air and bone conduction pure tone audiometry for both ears, without and with the use of the two masking methods. RESULTS: There was a 6.1% difference between the results for the air conduction threshold retest and a 15.1 % for the bone conduction threshold retest, taking into consideration the symmetrical model and a 12.8% for the bone conduction retest, considering the just bone model. There was no statistically significant difference between the air and bone conduction hearing thresholds with the two masking methods, considering unilateral and bilateral models. CONCLUSION: The plateau method can be utilized for all models and the optimized one is the most efficient for unilateral and bilateral models, having no indication for the symmetrical model. Therefore, both masking methods have presented advantages and disadvantages, implying that the audiologist must have knowledge of them in order to choose correctly the masking method to be used / INTRODUÇÃO: Na realização da audiometria tonal, determinadas situações dificultam a obtenção dos limiares para cada orelha separadamente, havendo a necessidade de utilização do mascaramento. O Método Platô, desenvolvido por Hood (1960), vem sendo o mais utilizado há mais de quatro décadas. Contudo, em 2004, Turner sugeriu um protocolo de mascaramento no qual um diferente método, denominado Método Otimizado, poderia substituí-lo de forma eficaz em casos específicos. OBJETIVO: Verificar se há diferença entre os limiares auditivos obtidos, por via aérea e via óssea, utilizando-se dois métodos de mascaramento clínico: o Método Platô e o Otimizado. MÉTODO: Participaram deste estudo 40 indivíduos, com idades entre 15 e 65 anos, que apresentavam perda auditiva unilateral ou bilateral, considerando os modelos unilateral, bilateral, simétrico e somente-ósseo, propostos pela classificação de Turner (2004). Foram realizados os procedimentos de audiometria tonal liminar por via aérea e óssea, para ambas as orelhas, sem e com a utilização dos dois métodos de mascaramento. RESULTADOS: Não houve diferença estatisticamente significante entre os limiares auditivos obtidos com os dois métodos de mascaramento por via aérea e via óssea considerando-se os modelos, unilateral e bilateral. No entanto, houve diferença de 6,1% dos resultados para o re-teste dos limiares por via aérea e de 15,1% para o re-teste por via óssea, considerando o modelo simétrico e de 12,8% para o re-teste de via óssea, considerando o modelo somente-ósseo. CONCLUSÃO: O Método Platô pode ser utilizado para todos os modelos e o Otimizado é mais eficaz para os modelos unilateral e bilateral, não sendo indicado para o modelo simétrico. Diante disso, ambos os métodos de mascaramento apresentaram vantagens e desvantagens, sugerindo que o audiologista tenha conhecimento destas para que proceda a seleção do método de forma consciente
36

Programa de Triagem Auditiva em crianças de risco em um Serviço de Saúde Auditiva de São Paulo / Hearing Screening Program in risk children in a Hearing Health Servide of São Paulo

Scaziotta, Monica de Almeida Cardillo-Martins 22 February 2007 (has links)
Made available in DSpace on 2016-04-27T18:12:20Z (GMT). No. of bitstreams: 1 Monica Cardillo-Martins.pdf: 724563 bytes, checksum: 8fa0beb198e22f36ba90f80c0a618b4d (MD5) Previous issue date: 2007-02-22 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A National Policy on Hearing Health Care was established in September 2004 in Brazil, giving the opportunity to structure health services in different levels of complexity, developing actions regarding prevention, detection, diagnosis and intervention of hearing problems in all ages. The present study describes the findings of an Infant Hearing Screening Program performed in a Hearing Health Service;55 high risk children, referred by a maternity hospital in São Paulo were evaluated. The methodology includes interview with mothers and the Hearing Screening, using Transient Evoked Otoacoustic Emissions (TEOAE), Distortion Product Otoacoustic Emissions (DPOAE), Auditory Brainstem Response (ABR), and eye blink reflex. The Hearing Screening attendancy rate was 76% (42 infants). The Hearing Loss prevalence was 14.3%, and all children showed conductive hearing loss. The most effective procedures in order to identify conductive hearing loss were TEOAE and ABR, when used together. The group who attended the screening program had lower weight, larger period of NICU hospitalization, higher number of risk indicators, less children in the family, higher family income per person and higher number of pre natal visits when compared to those who did not attend the screening test. No children with Sensorineural Hearing Loss were found, probably due to the sample s size. The findings show that Hearing Screening is viable to be conducted in Hearing Health Centers, if maternity staff is well committed with the Hearing Screening Program / Em setembro de 2004, foi instituída a Política Nacional de Atenção à Saúde Auditiva que estruturou os serviços em diferentes níveis de complexidade, atuando na prevenção, detecção, diagnóstico e intervenção das alterações auditivas. O estudo descreve os achados de um programa de triagem em 55 crianças de alto risco, encaminhadas de uma maternidade de São Paulo, realizado em um serviço de Saúde Auditiva. A metodologia incluiu a análise de prontuário, entrevista com as mães e a triagem auditiva por meio da pesquisa de emissão otoacústica evocada por estímulo transiente (EOAT), produto de distorção (EOAPD), potencial evocado auditivo de tronco encefálico (PEATE) e pesquisa do Reflexo Cócleo Palpebral (RCP). As características sócio-econômico-culturais do grupo que realizou e do que faltou na triagem foram comparadas. O comparecimento à triagem auditiva foi de 76% (42) e a prevalência de perda auditiva foi de 14,3%, sendo todas do tipo condutivo. Os procedimentos que se mostraram mais efetivos na identificação de perdas auditivas condutivas foram EOAT e PEATE aplicados em conjunto. O grupo que compareceu à triagem apresentou peso menor, maior período de internação na UTI, maior número de indicadores de risco, menor número de filhos, maior renda familiar por pessoa e maior número de consultas pré-natal, em comparação aos que não compareceram. Não foram encontradas crianças com perda auditiva do tipo neurossensorial, possivelmente devido ao tamanho da amostra. Os achados demonstram a viabilidade da realização da triagem em Centros de Referência em Saúde Auditiva
37

O cuidado com a saúde auditiva em motoristas de ônibus urbano em uma empresa de transporte coletivo no Rio de Janeiro

Rodrigues, Andrea Maria dos Santos January 2011 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2015-11-27T17:21:30Z No. of bitstreams: 1 Andrea Maria dos Santos Rodrigues.pdf: 1631844 bytes, checksum: c774a006e60a7f7184ae9622e64078b1 (MD5) / Made available in DSpace on 2015-11-27T17:21:30Z (GMT). No. of bitstreams: 1 Andrea Maria dos Santos Rodrigues.pdf: 1631844 bytes, checksum: c774a006e60a7f7184ae9622e64078b1 (MD5) Previous issue date: 2011 / Mestrado Profissional em Enfermagem Assistencial / Trata-se de uma pesquisa desenvolvida junto ao Mestrado Acadêmico em Ciências do Cuidado em Saúde que tem como objeto de estudo o cuidado com a saúde auditiva em motoristas de ônibus urbanos, considerando que a saúde auditiva é um dos aspectos fundamentais para a comunicação humana. A pesquisa fundamentou-se nos pressupostos teóricos da audição, na área da saúde do trabalhador e na perspectiva do cuidado em saúde, pois cuidar da saúde do trabalhador é buscar espaços e condições de trabalho saudáveis fazendo com que sua atividade diária seja cada vez menos prejudicial, tanto no campo físico quanto no campo psíquico. Os objetivos do estudo foram: identificar a existência de variação nos limiares auditivos dos motoristas de ônibus através das audiometrias ocupacionais ao longo de três anos consecutivos; verificar os saberes dos motoristas de ônibus urbano em relação aos riscos de exposição ao ruído e sobre o cuidado com sua saúde auditiva; descrever o Programa de Conservação Auditiva da Empresa de Transporte Coletivo; e discutir ações de cuidado com a saúde auditiva para compor o Programa de Conservação Auditiva. A abordagem metodológica utilizada foi um estudo de caso em uma empresa de transporte coletivo localizada na Cidade do Rio de Janeiro. A caracterização do estudo é observacional, do tipo coorte, que significa a seleção de indivíduos conforme o status de exposição, sendo acompanhados para avaliação da incidência de doença. Para análise dos dados estatísticos foram utilizados como métodos: ANOVA de Friedman para verificar a existência de variação significativa nas audiometrias, ao longo de três anos consecutivos; o teste de comparações múltiplas de Nemenyi, para identificar quais os anos que apresentam diferenças significativas entre si; e o teste dos postos sinalizados de Wilcoxon para verificar a existência de variação na audiometria entre as orelhas, direita e esquerda. Esta pesquisa foi aprovada pelo Comitê de Ética e Pesquisa do Hospital Universitário Antonio Pedro da Universidade Federal Fluminense (HUAP/ UFF) sob CAAE - 6141.0.000.258-10. Os resultados da pesquisa apontam que existem variações nos limiares auditivos dos motoristas de ônibus ao longo de três anos consecutivos, separadamente, por orelha. Comparando-se os limiares da orelha direita e esquerda observou-se que a orelha direita não apresentou diferenças significantes nas frequências analisadas dos exames audiométricos realizados, porém a orelha esquerda apresentou diferenças significativas em três frequências (500 Hz, 1000 Hz e 3000 Hz). De acordo com a Classificação da Portaria 19 (1998), evidenciou-se que houve uma redução do número de motoristas com exame de referência dentro dos limites de normalidade, em relação ao terceiro ano observado (exame sequencial). Cabe ressaltar, que a ocorrência das classificações de agravamento ou desencadeamento de Perda Auditiva Induzida por Ruído (PAIR) não foram identificadas na amostra avaliada. Destaca-se que os motoristas de ônibus em sua maioria não possuem conhecimento sobre os riscos de exposição e cuidados com a saúde auditiva, advindos da falta de informação. Esse estudo aponta que a atuação do fonoaudiólogo através de ações de cuidado inseridas no Programa de Conservação Auditiva é imprescindível para promover a saúde auditiva noambiente de trabalho. / This is a survey developed along the Academic Masters in health care sciences that have as an object of study the hearing health care in urban bus drivers, since the hearing health is one of the fundamental aspects to human communication. The survey was based on theoretical assumptions of the hearing, in the area of workers' health and the prospect of health care because care of workers' health is seeking spaces and healthy working conditions causing their daily activity to become less and less harmful, both in physical and psychic field. The objectives of the study were to: identify the existence of variation in auditory thresholds of bus drivers through the occupational audiometries over three consecutive years; verify the knowledge of urban bus drivers in relation to risks of exposure to noise and about the care of their health hearing; describe the company's Hearing Conservation program of Collective Transport; and discuss actions of hearing health care to compose the Hearing Conservation program. The methodological approach used was a case studied in a public transportation company located in the city of Rio de Janeiro. The characterization of the observational study is of a kind cohort, which means the selection of individuals as the exposure status, being monitored with a view to assessing the incidence of the disease. For analysis of the statistical data were used as methods: Friedman's ANOVA to verify the existence of significant variation in audiometries, over three consecutive years; multiple comparisons testing Nemenyi, to identify which year that have significant differences between themselves; and testing of flagged posts of Wilcoxon to verify the existence of variation in audiometry between the ears, right and left. This research was approved by the Ethics Committee and University Hospital Research Antonio Pedro of the Universidade Federal Fluminense (HUAPUFF) under CAAE-6141.0.000.258-10. Search results show that there are variations in the auditory thresholds of bus drivers over three consecutive years, separately, by ear. Comparing left and right ear thresholds observed that the right ear did not present significant differences in frequencies of audiometric tests conducted, analyzed but the left ear presented significant differences in three frequencies (500 Hz, 1000 Hz and 3000 Hz). According to the classification of the Gatehouse 19, it showed that there was a reduction in the number of drivers with reference examination within the bounds of normality, in relation to the third year observed (sequential examination). Please note that the occurrence of the trigger or worsen ratings for Noise-induced hearing loss (PAIR) were not identified in the sample evaluated. It is noteworthy that the bus drivers mostly do not have knowledge about the risks of exposure and hearing health care, from lack of information. This study points out that the actions of the audiologist through careful actions entered in the Hearing Conservation program is essential to promote hearing health in the working environment.
38

Zumbido: estudo dos mecanismos cocleares / Tinnitus: study of cochlear mechanisms

Buzo, Byanka Cagnacci 01 March 2013 (has links)
Introdução: O zumbido pode ser definido como a percepção consciente de um som, sem a participação de uma fonte sonora externa. A presença isolada do zumbido, sem a perda auditiva associada sugere que o mesmo pode ser o primeiro sintoma de alterações cocleares que somente serão percebidas depois do aparecimento da perda. Considerando que o zumbido está frequentemente relacionado a disfunções cocleares e mais especificamente a alterações nas células ciliadas, e que nesse caso as funções desempenhadas por elas podem estar comprometidas em algum grau, é possível que alterações nos mecanismos cocleares em pacientes com limiares auditivos ditos normais e queixa de zumbido sejam encontradas. Objetivo: O objetivo do presente estudo foi verificar as diferenças entre as respostas cocleares em mensurações eletroacústicas e psicoacústicas em indivíduos sem perda auditiva, com e sem queixa de zumbido. Método: Participaram do estudo 57 indivíduos com limiares audiométricos dentro dos padrões de normalidade, divididos em dois grupos: grupo-controle composto por 41 sujeitos (81 orelhas) sem queixa de zumbido, e grupo-zumbido composto por 16 sujeitos (31 orelhas) com queixa de zumbido. Os sujeitos foram submetidos à pesquisa das Curvas de Crescimento das Emissões Otoacústicas Produto de Distorção, pesquisa das Curvas Psicofísicas de Sintonia e aplicação do teste TEN. Resultados: Para as CC-EOAPD somente foi observada diferença estatística nas curvas de 3000 e 6000 Hz, para L2=45 dBNPS e L2=55 dBNPS, respectivamente. Para as curvas psicofísicas de sintonia, foram observadas diferenças estatísticas localizadas nas extremidades das curvas, isto é, para a CPS de 2000 Hz com ruído de 6000 e 8000, para a CPS de 3000 Hz, para 8000 Hz, para a CPS de 4000 Hz para o ruído de 2000 e 8000 Hz e para as CPS de 6000 e 8000 Hz para os ruídos de 3000 e 2000 Hz. Para o teste TEN, não foi encontrada presença de zonas mortas da cóclea, entretanto foi observado padrão diferente entre os grupos, caracterizado pelo limiar na presença de ruído ipsilateral estatisticamente mais elevado no grupo-zumbido do que no grupo-controle. Conclusão: Foi observado que apesar de audiologicamente normais, os grupos apresentam desempenhos estatisticamente distintos nos testes aplicados, principalmente nas Curvas Psicofísicas de Sintonia e no teste TEN, evidenciando funcionamentos cocleares diferentes que, possivelmente, comprometem em algum grau os mecanismos cocleares, principalmente a seletividade de frequência / Introduction: Tinnitus can be defined as the conscious perception of a sound without the participation of an external sound source. The association between tinnitus and hearing loss has been well described. The isolated presence of tinnitus, without hearing loss, suggests that it may be the first symptom of cochlear dysfunctions that will be noticed only after the emergence of the hearing loss. Whereas tinnitus is often related to cochlear dysfunction, specifically in hair cells, their mechanisms could be impaired to some degree. Thus, patients with normal hearing and tinnitus, could show some dysfunctions in cochlear mechanisms. Objective: The aim of this study was to investigate the differences between the cochlear responses in electroacoustic and psychoacoustic measurements in subjects with normal hearing, with and without tinnitus. Method: The study included 57 subjects with audiometric thresholds within normal limits, divided into two groups: control group consisted of 41 subjects (81 ears) without tinnitus and tinnitus group consisted of 16 subjects (31 ears) with tinnitus. The subjects were tested for DPOAE-I/O functions, Psychophysical Tuning Curves (PTC) and TEN test. Results: For DPOAE-I/O only statistical difference was observed in the curves of 3000 and 6000 Hz, for L2 = 45 dBSPL and L2 = 55 dBSPL respectively. For the psychophysical tuning curves, statistical differences were observed at the ends of the curves, i.e. for the PTC 2000 Hz with noise 6000 and 8000 to 3000 PTC Hz to 8000 Hz to 4000 Hz PTC for noise 2000 and 8000 Hz and the PTC 6000 and 8000 Hz for the noise of 3000 Hz and 2000 TEN For the TEN test, there were no presence of \"dead regions in the cochlea,\" however different pattern was observed among groups, characterized by the presence of noise threshold ipsilateral statistically higher in the tinnitus group than the control group. Conclusion: We found that despite normal hearing, the groups have statistically different performances in the test applied, especially in psychophysical tuning curves and the TEN test, showing that different runs cochlear possibly commit to some degree the cochlear mechanisms, mainly the frequency selectivity
39

Estudo da saúde auditiva em adultos jovens da área odontológica / Hearing health at the dentistry young adults: knowledge and audiological profile

Santos, Cibele Carméllo 31 May 2011 (has links)
Introdução: Profissionais da área odontológica lidam diariamente com instrumentos que emitem ruído, o que pode vir a causar alterações auditivas e efeitos negativos na comunicação e na qualidade de vida desses profissionais. Considerando o fato de que tais ruídos não podem ser eliminados, é importante que a conscientização dos futuros profissionais da odontologia seja iniciada ainda no início do curso universitário, mencionando os riscos a que estarão sendo expostos para que possam controlá-los com prevenção e tratamento, bem como obter informações consistentes a respeito do comportamento dos limiares auditivos dos cirurgiões-dentistas. Objetivo: Investigar o conhecimento de alunos do curso de graduação em Odontologia sobre saúde auditiva e caracterizar o perfil audiológico e os hábitos auditivos dos participantes da pesquisa. Metodologia: Após a aprovação do Comitê de Ética sob o processo número 045/2009, o projeto foi realizado em duas etapas. A primeira constituiu-se da aplicação de questionários aos 367 alunos dos cursos de graduação em Odontologia da Faculdade de Odontologia de Bauru FOB/USP e USC e da Faculdade de Odontologia de São Paulo FO/USP. Na segunda etapa, 25 alunos do primeiro e quarto anos de graduação das faculdades de Bauru foram convidados a realizar as seguintes avaliações: audiológica convencional, logoaudiometria, imitanciometria e a avaliação complementar (audiometria de altas frequências e emissões otoacústicas transientes e por produto de distorção). Resultados: Na primeira etapa, verificou-se que os alunos desconhecem o risco que o ambiente ocupacional e de lazer proporcionam à saúde auditiva e, desse modo, verificou-se que se faz necessária a conscientização sobre a exposição do ruído e suas consequências a fim de criar um programa de promoção e prevenção principalmente na saúde ocupacional dessa população, considerando que essa problemática interfere na qualidade de vida dos que atuam na profissão odontológica. Na segunda etapa completaram as provas 25 participantes (X= 23 anos). Apesar dos limiares se encontrarem de acordo com a normalidade para a OMS (Organização Mundial de Saúde) e também para a Portaria nº 19 do Ministério do Trabalho, houve uma entalhe na frequência de 6 kHz e 12,5 kHz em ambas as orelhas na audiometria convencional e audiometria tonal de altas frequências. A média mínima encontrada na orelha direita foi de 4,6 dB em 14 kHz e para a orelha esquerda foi de 4 dB em 1 kHz e a média máxima para a orelha direita foi de 12,4 dB em 6 kHz e para a orelha esquerda foi de 14 dB em 6 kHz. Para a logoaudiometria e imitanciometria, 100% dos participantes apresentaram exame de forma compatível com a audiometria convencional. No registro das EOE, pôde-se verificar que quanto maior o limiar de audibilidade nas frequências estudadas mais se evidencia a ausência das EOE-t e EOE-DP para ambas as orelhas, exceto na comparação do limiar de audibilidade em 1 kHz nas EOE-t, provavelmente devido à contaminação pelo ruído de fundo durante o registro das mesmas e na frequência de 3 kHz nas EOE-DP. Conclusão: Os questionários aplicados se mostraram eficientes atingindo o objetivo proposto. Quanto à caracterização do perfil audiológico foi possível concluir que o exame de emissões otoacústicas tanto transientes quanto por produto de distorção se mostraram mais eficientes como um exame complementar para identificar precocemente as alterações auditivas nessa população. / Introduction: Professionals of the dental area handle daily with noisy instruments, what may come to cause audibly alterations and negative effects at the communication and life quality of these professionals. Considering the fact that such noise can not be eliminated, it is important that the awareness of future dental professionals is initiated early on in the university, mentioning the risks to which they are being exposed so that they can control them with prevention and treatment, as well as acquire consistent information about the behavior of the auditory thresholds of surgeon dentists. Objective: To investigate the knowledge about hearing health of students of graduation in odontology, characterize the audiological profile and listening habits of the research participants. Methodology: After approval by the Ethics Committee under case number 045/2009, the project was conducted in two stages. The first consisted of questionnaires to 367 students of undergraduate courses in Odontology from the Faculty of Odontology of Bauru FOB/USP and USC and from Faculty of Odontology of São Paulo FO/USP. In the second stage, 25 students from first and fourth years of undergraduate faculties of Bauru were invited to conduct the following assessments: audiometry, speech audiometry, impedance tests and additional assessment (high frequency audiometry and otoacoustic emissions and distortion product). Results: In the first stage, it was observed that students are unaware of the risk the workplace and the leisure environment provide the hearing health and, thereby, it was verified that awareness is needed about noise exposure and its consequences, in order to create a program of promotion and prevention, especially in occupational health in this population, considering that this problem affects the quality of life of those who work in the dental profession. In the second phase 25 participants completed the tests (X = 23 years). Although the thresholds meet according to normality by the WHO (World Health Organization) and also to Ordinance No. 19 of Ministry of Labor, there was a notch in the frequency of 6 kHz and 12,5 kHz in both ears in conventional audiometry and high frequency audiometry. The average minimum found in the right ear was 4.6 dB at 14 kHz to the left ear was 4 dB at 1 kHz and the average maximum for the right ear was 12.4 dB at 6 kHz and to the left ear was 14 dB at 6 kHz. For speech audiometry and immittance, 100% of the participants presented examination consistent with conventional audiometry. In the record of EOE, it was found that the higher the threshold of audibility frequencies studied, the more evident is the lack of EOE-t and EOE-DP for both ears, except when comparing the hearing threshold at 1 kHz in the EOE-t, probably due to contamination by background noise during the registration thereof and in the frequency of 3 kHz in the EOE-DP. Conclusion: The questionnaires applied proved to be efficient, reaching the objective. As for the characterization of the audiological profile, it was concluded that, the test of both transient otoacoustic emissions and distortion product, proved more efficient as a complementary test for early detection of hearing alterations in this population.
40

"Audiometria de altas freqüências em indivíduos com audição normal entre 250 e 8.000 Hz com e sem queixa de zumbido" / High frequency audiometry in individuals with normal hearing between 250 and 8.000 Hz with and with no tinnitus complaint

Guedes, Ana Paula de Souza 31 August 2005 (has links)
Indivíduos com audição normal entre 250 e 8.000 Hz podem apresentar zumbido. Além da avaliação audiológica convencional, a audiometria de altas freqüências tem sido aplicada nestes casos. O objetivo desta pesquisa foi avaliar os limiares de audibilidade nas altas freqüências em indivíduos com audição normal entre 250 e 8.000 Hz com e sem queixa de zumbido. A pesquisa foi realizada em 33 indivíduos com zumbido e 33 sem zumbido. Houve piora estatisticamente significante entre os limiares de audibilidade dos indivíduos com zumbido em relação aos indivíduos sem zumbido para as seguintes freqüências: 9.000, 10.000, 12.500, 14.000, 16.000, 18.000 e 20.000 Hz / Subjects with normal hearing between 250 and 8.000 Hz may show tinnitus. Beyond the conventional audiological evaluation, the high frequency audiometry has been applied in these cases. The research's goal was to evaluate the audibility thresholds in high frequencies in subjects with normal hearing between 250 and 8.000 Hz with and with no tinnitus complaint. The research was carried through in 33 individuals with tinnitus and 33 with no tinnitus. A significant statistical worsening occurred between hearing thresholds of subjects with tinnitus with relation to subjects with no tinnitus for the following frequencies: 9.000, 10.000, 12.500, 14.000, 16.000, 18.000 and 20.000 Hz

Page generated in 0.0486 seconds