• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 79
  • 34
  • 11
  • 2
  • Tagged with
  • 122
  • 62
  • 27
  • 20
  • 18
  • 15
  • 15
  • 14
  • 14
  • 13
  • 13
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Impact de l'extinction génique de la sialoprotéine osseuse (BSP) sur la différenciation des ostéoblastes et l'ostéogenèse in vitro : développement et validation d'un bioréacteur pour la culture ostéoblastique en trois dimensions / Effect of bone sialoprotein (BSP) knockout on osteoblast differentiation and osteogenesis in vitro : development and validation of a bioreactor for osteoblastic cultures in three dimensions

Bouët, Guénaëlle 23 September 2013 (has links)
La culture cellulaire traditionnelle en deux dimensions (2D) ne peut pas reproduire les propriétés des tissus observées dans des organes en trois dimensions (3D). Ces tissus, en particulier les tissus de soutien comme l'os, sont soumis à des contraintes mécaniques, facteurs majeurs de régulation des interactions cellulaires et cellules/matrices. Il y a donc un intérêt croissant pour les modèles 3D, afin de mieux comprendre les différents aspects du fonctionnement cellulaire et du remodelage osseux, dans des systèmes de moindre complexité que les modèles in vivo. Nous nous sommes intéressés ici aux cellules ostéoblastiques et à une de leur protéine matricielle, la sialoprotéine osseuse (BSP). La BSP appartient à la famille des "small integrin-binding ligand N-linked glycoproteins" (SIBLING), impliquées dans le développement, le remodelage et la minéralisation de l’os, et répondant rapidement à la contrainte mécanique. Notre objectif était d’analyser l’impact de cette protéine sur la différenciation ostéoblastique et l’ostéogénèse in vitro à partir de cellules de calvaria de souris présentant une extinction génique de la BSP (BSP-/-) cultivées en 2D et en 3D. Nous avons montré que les cellules BSP-/- présentaient un défaut de formation osseuse et de minéralisation qui est dépendant de la densité cellulaire. Puis nous avons développé et validé un bioréacteur perfusé et stimulable mécaniquement via le système ZetOsTM. Les premiers résultats obtenus avec cet outil contrôlé montrent que l’environnement 3D améliore la différenciation des cellules BSP-/-. Ces travaux restent à développer, notamment pour analyser l’effet des contraintes mécaniques sur ces cellules / Traditional (2D) cell culture cannot reproduce the tissue properties observed in 3 dimensional organs (3D). Weight-bearing organs such as bone are subjected to mechanical stresses, which are major regulating factors for cell and cell/matrix interactions. There is thus a growing interest in 3D culture models, in order to better understand the different aspects of cell function and bone remodeling in systems less complex than in vivo models. We are interested here in the osteoblastic cells and in one of their matrix proteins, the bone sialoprotein (BSP). BSP belongs to the family of the "small integrin -binding ligand N -linked glycoproteins" (SIBLING), involved in the development, remodeling and mineralization of bone, and responding quickly to mechanical stress. Our goal in this work was to analyze the impact of the absence of this protein on osteoblast differentiation and bone formation in vitro from mouse calvarial cells (MCC) with a gene knockout of BSP (BSP-/-), grown in 2D and 3D. We have shown that BSP-/- cells have a defect in bone formation and mineralization which is cell density dependent. We have developed and validated a perfused bioreactor able to apply mechanical stress to culture scaffolds via the ZetOsTM system. Our first results with this powerful tool show that a 3D environment improves BSP-/- cells differentiation. This work remains to be developed, in particular to analyze the effects of mechanical stress on these cells
92

Caractérisation de l'effet de traitement de nanocristallisation superficielle (SMAT) sur un alliage CoCrMo / Effect characterisation of a superficial nanocrystallisation treatment (SMAT) on a CoCroMo alloy

Tchana Nkonta, Daniella Vashti 06 February 2017 (has links)
Ce travail a pour objectif d’évaluer le comportement à l’usure de pièces en CoCrMo utilisé dans l’orthopédie. Le procédé de nanocristallisation superficielle SMAT (Surface Mechanical Attrition Treatment) couplé à un polissage biomédical a été mis en œuvre dans cette étude pour améliorer les propriétés mécaniques, tribocorrosives d’un alliage CoCrMo. Dans un premier temps, une optimisation des paramètres SMAT sur un alliage CoCrMo a été réalisée. Différentes techniques de finition de surface ont ensuite été étudiées afin d’obtenir un état de surface acceptable pour des implants orthopédiques. Des techniques de caractérisation microstructurale ont alors été mises en œuvre sur des échantillons SMATés et polis : microscopie électronique à balayage et transmission (MEB ; MET), diffraction des électrons rétrodiffusés (EBSD), diffraction de kikuchi en transmission (TKD) et diffraction des rayons X (DRX). Les résultats obtenus ont montré que le traitement SMAT peut créer un raffinement des grains en surface de l’alliage CoCrMo avec notamment la présence de nano-grains en extrême surface. Des mesures d’indentation ainsi que des essais par la méthode du trou incrémental ont été effectués. Une augmentation de plus de 30% de la dureté a ainsi été observée après SMAT ainsi que la génération de contraintes résiduelles superficielles de compression. Les propriétés tribocorrosives de l’alliage CoCrMo ont également été étudiées par des essais d’usure par pion disque, scratch tests et des essais électrochimiques avant et après SMAT. / This aims of this work is to evaluate the wear behavior of CoCrMo parts used in orthopedics. The Surface Mechanical Attrition Treatment (SMAT) method coupled with biomedical polishing has been used in this study to improve the mechanical and tribocorrosive properties of a CoCrMo alloy. In a first step, an optimization of the SMAT parameters on a CoCrMo alloy was carried out. Different surface finishing techniques were then studied to obtain an acceptable surface finish for orthopedic implants. Microstructural characterization techniques were then applied on SMATed and polished samples: scanning and transmission electron microscopy (SEM, MET), backscattered electron diffraction (EBSD), transmission kikuchi diffraction (TKD), and ray diffraction X (XRD). The results obtained showed that the SMAT treatment can create a refinement of the surface grains of the CoCrMo alloy with the presence of nano-grains in the extreme surface. Indentation measurements as well as incremental hole tests were performed. An increase of more than 30% of the hardness was observed after SMAT as well as the generation of residual surface compressive stresses. The tribocorrosive properties of the CoCrMo alloy were also studied by disk wear tests, scratch tests, and electrochemical tests before and after SMAT.
93

Recherche de nouvelles stratégies thérapeutiques des métastases osseuses : utilisation de la chimiokine CX3CL1 ou de ciments chargés en bisphosphonates / Research of new therapeutic strategies for bone metastases : use of CX3CL1 or bisphosphonate-loaded calcium phosphate cements as new therapeutic tools

Al-Sahlanee, Rasha 28 October 2016 (has links)
Malgré les avancées thérapeutiques récentes, le pronostic des patients porteurs de métastases osseuses (MO) reste faible, ce qui incite à chercher des nouvelles stratégies thérapeutiques. Les chimiokines sont des acteurs majeurs de la réponse immune, et apparaissent comme des cibles potentielles de l’immunothérapie anti-cancéreuse. Nous avons recherché à définir si la chimiokine CX3CL1 pouvait représenter un axe thérapeutique efficace dans le contexte des MO. Pour cela nous avons développé des modèles murins de MO de cancer du rein et du poumon. Dans le modèle de MO de cancer du poumon, notre travail a démontré que l'expression de CX3CL1 inhibe la croissance tumorale. L’analyse transcriptomique des tumeurs a montré que CX3CL1 diminue (i) l’ostéloyse via un effet sur la triade OPG/RANKL/RANK (ii) l'expression de certains checkpoints, en faveur d’une réponse immune antitumorale. En revanche, dans le modèle de MO de cancer du rein, l’expression de CX3CL1 stimule le développement tumoral et l'ostéolyse via une action sur la triade OPG/RANKL/RANK et inhibe la réponse immune antitumorale via une augmentation de l'expression de certains checkpoints immunitaires. Les bisphosphonates (BPs) sont des agents utilisés pour le traitement des MO. Afin de réduire leurs effets indésirables, nous avons utilisé des ciments de phosphate de calcium (CPC), pour délivrer localement dans l’os des BPs (alendronate, ALN). Notre travail a mis en évidence que (i) ces ciments chargés en ALN relarguent en continue les BPs, (ii) le relarguage d’ALN est efficace pour induire des effets cytotoxiques et pro-apoptotiques vis à vis des cellules de cancer du sein / Despite recent therapeutic improvments, the prognosis for a patient with bone metastases (BM) remains poor, this situation prompting the research of new therapeutic strategies. Chemokines are central players in the immune response, and appear as potential targets in anti-cancer immunotherapies. We are interested to determine whether the CX3CL1 chemokine exerted pro or anti-tumor actions within the bone metastatic context. To address this issue, we developed mouse models of lung or renal cancer BM. In lung cancer BM model, our work demonstrated that CX3CL1 expression led to tumor growth inhibition. Tumors transcriptomic analysis revealed that CX3CL1: (i) impacted bone metabolism by modulating the OPG/RANKL/RANK triad (ii) decreased the expression of certain immune checkpoints, this up-regulating the anti-tumor immune response. By contrast, in renal cancer BM model, CX3CL1 expression stimulated bone tumor development and transcriptomic analysis showed that CX3CL1 (i) promoted osteolysis through an action on the OPG/RANKL/RANK triad (ii) -induced tumor development correlated with an increased expression of certain immune checkpoints, this down-regulating the anti-tumor immune response. Bisphosphonates (BPs) are targeted agents used for BM treatment. In order to reduce their side effects, we used resorbable calcium phosphate cements (CPC), which are frequently used as bone void fillers, as platform for a local delivery of BPs (alendronate, ALN). As a whole, our in vitro data demonstrated that: (i) ALN-CPC cements continuous released ALN; (ii) this ALN release was effective in inducing cytotoxic and pro-apoptotic effects in breast cancer cells
94

Développement d'un implant biodégradable à base de gentamicine et de monoléine destiné au traitement des ostéomyélites chroniques

Ouedraogo, Moustapha 22 February 2008 (has links)
L’ostéomyélite chronique est une infection chronique du tissu osseux et de la moelle. C’est une infection grave du fait de sa localisation au sein d’un tissu profond, de la complexité de sa prise en charge thérapeutique et de la mise en jeu du pronostic fonctionnel. L’incidence de l’ostéomyélite chronique est accrue sur certains terrains (drépanocytose, diabète, et polyarthrite rhumatoïde entre autres). Son traitement classique repose sur un curettage chirurgical associé à une antibiothérapie par voie générale durant au moins 6 semaines. Ce traitement est marqué le plus souvent par des échecs du fait de la difficulté de faire parvenir des antibiotiques à doses efficaces et de manière prolongée ou continue au niveau de l'os infecté.<p>\ / Doctorat en Sciences biomédicales et pharmaceutiques / info:eu-repo/semantics/nonPublished
95

Injectable hydrogels for innovative clinical applications / Hydrogels injectables pour applications cliniques innovants

Alonci, Giuseppe 12 December 2018 (has links)
Cette thèse porte sur la conception d'hydrogels injectables pouvant être utilisés en chirurgie mini-invasive, par exemple en dissection endoscopique sous-muqueuse (ESD) ou en réparation de hernie.Les polyamidoamines (PAAm) constituent une classe d'hydrogel intéressante à ces fins. Après avoir étudié les différents facteurs qui affectent leurs propriétés, nous montrons qu'il est également possible d'obtenir des microgels à base de PAAm pour la délivrance de médicaments ou l'encapsulation de cellules. Il est possible de synthétiser des PAAm dégradables qui peuvent être injectés dans la sous-muqueuse de l'estomac pour la ESD.Nous avons montré que les hydrogels hybrides alginate / PAAm peuvent être utilisés pour le traitement percutané de la hernie inguinale directe et des crèmes à base d'hydrogel ont été préparées pour être utilisées pour le colmatage des fistules. Le dernier chapitre de la thèse est consacré à la réticulation de l'acide hyaluronique pour la chirurgie esthétique. / This thesis deals with the design of injectable hydrogels that can be used in minimally invasive surgery, such as endoscopic submucosal dissection (ESD), percutaneous hernia repair or fistulas closure.Polyamidoamines (PAAm) constitute a class of hydrogel of special interest for these purposes. After studying the different factors that affect their properties, we show that it is also possible to obtain PAAM-based microgels for applications in drug delivery or cell encapsulation.It is possible to synthesize redox-responsive nanocomposite degradable PAAm that can be injected into the submucosa of the stomach to facilitate the ESD.We show that hybrid alginate/PAAm hydrogels can be used for the percutaneous treatment of direct inguinal hernia and hydrogel-based creams have been prepared for use in fistulas closure. The last chapter of the thesis is devoted to the development of a new crosslinking strategy for hyaluronic acid in cosmetic surgery.
96

Elaboration de bio-systèmes à relargage retardé de principes actifs : hydrogels physiques de chitosane fonctionnalisés par des liposomes / Development of bio-systems for drug delayed-release : Liposomes embedment into chitosan physical hydrogels

Peers, Soline 22 February 2019 (has links)
L’objectif de ce travail de recherche est le développement d’un biomatériau original permettant la libération retardée de principes actifs afin de résoudre les problématiques de diffusion trop rapide ou incontrôlée souvent rencontrées avec les systèmes de délivrance classiques. Un assemblage « hybride » composé de liposomes incorporant le principe actif, eux-mêmes incorporés dans un hydrogel physique de chitosane a été mis au point dans le cadre de ce travail. Pour élaborer ce système, une suspension de liposomes préformés est ajoutée à une solution de chitosane avant sa gelification. Une caractérisation des différents composants ainsi qu’une optimisation de ce processus d’élaboration ont été effectuées au cours de cette thèse. Les propriétés de relargage ont été étudiées via l’incorporation d’une molécule hydrosoluble jouant le rôle de modèle de principe actif. La carboxyfluorescéine (CF), dosable par fluorescence, a permis de confirmer le concept de « relargage retardé » : la quantité de CF libérée au cours du temps est plus élevée lorsque cette dernière est directement incorporée dans l’hydrogel, par rapport au cas où elle est intégrée dans l’assemblage « hybride ». Sur la base de ces résultats, l’incorporation et le relargage de deux principes actifs, la rifampicine (RIF), un antibiotique à large spectre, et la lidocaïne, un anesthésique local anti-arythmique, ont également été étudiées. Ce travail a permis de confirmer les résultats obtenus pour la molécule modèle, à savoir un retard au relargage significatif pour les assemblages par rapport aux hydrogels sans liposome. Diverses caractérisations ont également été menées pour examiner les propriétés rhéologiques et la morphologie de ces assemblages. Ces résultats représentent une avancée intéressante pour la valorisation de tels assemblages « hybrides » dans le domaine biomédical, et mettent en évidence le rôle des liposomes en tant que « réservoirs » de principes actifs au sein même de ces assemblages. / This work deals with the development of an original biomaterial in view of its application as drug delayed-release device in biomedical area. To overcome classic issues that may be encountered with common drug delivery systems such as the “burst effect” or fast outside diffusion of drugs, a « hybrid » system composed of liposomes entrapped within a chitosan physical hydrogel was developed. Its elaboration process consists in the addition of a suspension of pre-formed phosphatidylcholine liposomes within a chitosan solution before gelation process. A characterization of different components of the system and an optimization of the elaboration process were achieved. The release properties were firstly investigated using a water-soluble fluorescent model molecule, carboxyfluorescein (CF). The concept of delayed-release was confirmed. Indeed, the release of CF, assayed by fluorescence spectroscopy, was found to be higher in the “drug-in-hydrogel” systems in comparison with the “drug-in-liposomes-in-hydrogels” ones. Based on these results, the release of two drugs, rifampicin (RIF), a broad spectrum antibiotic, and lidocaine (LID), a local anaesthetic and anti-arrhythmic drug, were also studied. This work corroborated the data obtained for the model molecule, that is to say a significant delayed release for « hybrid » systems in comparison to hydrogels without liposome. Various characterizations were carried out to examine rheological properties and morphologies of assemblies. These first results showed that such systems could be a step forward in drug delivery, and highlighted the use of liposomes as drug « reservoirs » within assemblies.
97

L'évaluation de la génotoxicité des biomatériaux métalliques par l'essai « in situ end-labeling » en microscopie électronique

Assad, Michel 07 1900 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal. / Des études cliniques ont démontré que certains implants métalliques pouvent déclencher des réactions de carcinogénicité. En effet, il semble que le relargage ionique et la corrosion peuvent initier des néoplasmes. Le noyau semble être le compartiment cellulaire cible de ces ions métalliques. Le développement d'essais quantitatifs in vitro capables d'évaluer cette carcinogénicité potentielle est donc essentiel dans la présélection des biomatériaux métalliques. Cependant à l'échelle ultrastructurale, actuellement il n'existe pas véritablement d'essais capables de localiser et de quantifier à la fois les dommages occasionnés à la molécule d'ADN ainsi qu' à sa réparation. Dans ce travail, il s'agissait d'abord d'adapter, en biocompatibilité, une méthode simple capable de détecter, quantifier et localiser précisément les cassures d'ADN qu'induisent les biomatériaux métalliques à la chromatine cellulaire. Pour ce faire, l'essai «in situ end-labeling » (ISEL) en microscopie électronique a été évalué après avoir utilisé un protocole d'extraction des biomatériaux en conditions semi-physiologiques et exposé des lymphocytes sanguins humains normaux. Cette technique immunocytochimique utilise l'exonucléase III pour sa capacité de digérer et d'amplifier les lésions d'ADN produites. Une polymérisation est ensuite exécutée en présence des quatre nucléotides de l'ADN: la thymidine est toutefois remplacée par une base analogue, soit la biotine-dUTP. Cette dernière est localisée par marquage immunologique à l'or colloïdal comme rapporteur moléculaire. Les particules d'or sont alors détectées en microscopie électronique à transmission; elles correspondent aux cassures simple-brin induites à la molécule d'ADN lors de la culture de cellules en présence de l'extrait à étudier. La quantification a été effectuée avec l'aide du Programme Image du NIH. L'ISEL s'est avéré très utile pour sa rapidité, sa capacité de marquer à la fois la chromatine interphasique et métaphasique, et la possibilité de quantifier les dommages causés à l'ADN. Par ailleurs, il ne nécessite pas l'utilisation de la radioactivité. De plus, il semble capable de détecter des phénomènes de mort cellulaire telle que l apoptose. L'« in situ end-labeling » en microscopie électronique s'avère aussi un instrument intéressant pour la présélection des biomatériaux. En effet, la génocompatibilité du titane (Ti) pur, bien connu pour sa biocompatibilité, a été évaluée afin de valider cet essai. Ensuite, la génotoxicité relative du nickel-titane (NiTi) a été évaluée et comparée à celle du titane pur, du nickel (Ni) pur et de l'acier inoxydable. Le NiTi représente un biomatériau potentiel, cependant sa biocompatibilité est controversée vu son important contenu en nickel soit de 50%. L'évaluation de la carcinogénicité du NiTi représente donc un intérêt important. Un essai d'absorption atomique a aussi été réalisé afin d'évaluer le relargage de nickel et de titane, et afin de mieux comprendre le rôle des ces ions dans la carcinogénicité métallique. L'ISEL a semblé ici tout aussi utile dans l'évaluation de la biocompatibilité du nickel-titane. En effet, grâce à cet essai, des résultats fort encourageants ont été obtenus avec le NiTi. Ce dernier a donné des résultats comparables à ceux du titane pur. Par contre, l'acier inoxydable 316-L peut dans certains cas produire aussi des dommages à la chromatine. Par conséquent, cet essai in vitro de génotoxicité nous permet d'être optimiste quand à l'utilisation éventuelle de NiTi à titre d'implant chirurgical permanent.
98

Le larynx artificiel : de l'in vitro à la première implantation clinique

Bories, Agnès 30 September 2013 (has links) (PDF)
Objectifs : Ce travail a pour but de développer un larynx artificiel composé de 2 structures : 1) une structure inamovible en titane poreux prolongeant la trachée; 2) une double valve remplissant la fonction de sphincter. Matériels et Méthodes : L'intégration de la prothèse en remplacement trachéal a été testée in vitro et in vivo sur les modèles animaux rats, lapins et brebis. Suite à l'ensemble de ces résultats, nous avons réalisé la première application clinique du larynx artificiel. Résultats : 1) L'ajout d'un tube de silicone endoprothétique améliore la survie chez le gros animal; 2) l'intégration tissulaire de la prothèse de trachée associée à un matériel polymérique biodégradable était supérieure à celle des prothèses en titane poreux nu; 3) la vitesse de colonisation des prothèses en titane poreux était accélérée lorsque l'on diminuait la taille des billes. Un premier patient a été implanté avec une prothèse de larynx artificiel avec des résultats satisfaisants à 9 mois. Conclusions : Nos études concernant l'intégration de prothèses de trachées in vitro et in vivo ont permis de contribuer à l'aboutissement de la première application clinique de larynx artificiel.
99

Caractérisation de systèmes biologiques à l'échelle nanométrique : études des interactions entre des modèles membranaires et des agents exogènes

Beauvais, Estelle 15 October 2013 (has links) (PDF)
Les membranes biologiques sont impliquées dans divers mécanismes comme la reconnaissance moléculaire ou encore la fusion membranaire. Les lipides, principaux composants des membranes, sont inhérents à ces processus cellulaires, mais leur organisation et leur rôle fonctionnel au sein de ces systèmes sont très complexes. Dans ce travail, nous avons utilisé des modèles membranaires mimant ces systèmes biologiques pour identifier les interactions mises en jeu avec divers agents exogènes (AEs), en utilisant la microscopie à force atomique (AFM). Nous avons donc travaillé sur deux AEs différents qui interagissent potentiellement avec ces membranes. Le premier intervient directement dans le cadre de l'étude du paludisme. Le mécanisme moléculaire de cette maladie (impliquant probablement des structures lipidiques) n'étant pas clair, la compréhension de celui-ci faciliterait le développement de nouvelles molécules antipaludiques et/ou cibles thérapeutiques. Parallèlement notre étude s'est portée sur l'interaction des nanoparticules (NPs) de TiO2, notre second AE, avec les membranes. Très utilisées dans l'industrie, ces NPs de TiO2 pourraient avoir un impact sur la santé humaine, en interagissant notamment avec les membranes cellulaires. Des techniques biophysiques classiques ont tout d'abord été utilisées pour évaluer l'interaction de l'AE avec des systèmes biomimétiques. Ensuite, lorsque celle-ci est prouvée, l'AFM est utilisée pour visualiser les changements morphologiques des modèles membranaires en présence de ces AEs. Ainsi, pour chaque AE, nous avons finalement suggéré un mécanisme d'interaction afin de répondre aux problématiques soulevées.
100

L'élastographie ultrasonore dynamique vasculaire : une nouvelle modalité d'imagerie non-invasive pour la caractérisation mécanique de la thrombose veineuse

Schmitt, Cédric 04 1900 (has links)
L’accident thromboembolique veineux, tel que la thrombose veineuse profonde (TVP) ou thrombophlébite des membres inférieurs, est une pathologie vasculaire caractérisée par la formation d’un caillot sanguin causant une obstruction partielle ou totale de la lumière sanguine. Les embolies pulmonaires sont une complication mortelle des TVP qui surviennent lorsque le caillot se détache, circule dans le sang et produit une obstruction de la ramification artérielle irriguant les poumons. La combinaison d’outils et de techniques d’imagerie cliniques tels que les règles de prédiction cliniques (signes et symptômes) et les tests sanguins (D-dimères) complémentés par un examen ultrasonographique veineux (test de compression, écho-Doppler), permet de diagnostiquer les premiers épisodes de TVP. Cependant, la performance de ces outils diagnostiques reste très faible pour la détection de TVP récurrentes. Afin de diriger le patient vers une thérapie optimale, la problématique n’est plus basée sur la détection de la thrombose mais plutôt sur l’évaluation de la maturité et de l’âge du thrombus, paramètres qui sont directement corrélées à ses propriétés mécaniques (e.g. élasticité, viscosité). L’élastographie dynamique (ED) a récemment été proposée comme une nouvelle modalité d’imagerie non-invasive capable de caractériser quantitativement les propriétés mécaniques de tissus. L’ED est basée sur l’analyse des paramètres acoustiques (i.e. vitesse, atténuation, pattern de distribution) d’ondes de cisaillement basses fréquences (10-7000 Hz) se propageant dans le milieu sondé. Ces ondes de cisaillement générées par vibration externe, ou par source interne à l’aide de la focalisation de faisceaux ultrasonores (force de radiation), sont mesurées par imagerie ultrasonore ultra-rapide ou par résonance magnétique. Une méthode basée sur l’ED adaptée à la caractérisation mécanique de thromboses veineuses permettrait de quantifier la sévérité de cette pathologie à des fins d’amélioration diagnostique. Cette thèse présente un ensemble de travaux reliés au développement et à la validation complète et rigoureuse d’une nouvelle technique d’imagerie non-invasive élastographique pour la mesure quantitative des propriétés mécaniques de thromboses veineuses. L’atteinte de cet objectif principal nécessite une première étape visant à améliorer les connaissances sur le comportement mécanique du caillot sanguin (sang coagulé) soumis à une sollicitation dynamique telle qu’en ED. Les modules de conservation (comportement élastique, G’) et de perte (comportement visqueux, G’’) en cisaillement de caillots sanguins porcins sont mesurés par ED lors de la cascade de coagulation (à 70 Hz), et après coagulation complète (entre 50 Hz et 160 Hz). Ces résultats constituent les toutes premières mesures du comportement dynamique de caillots sanguins dans une gamme fréquentielle aussi étendue. L’étape subséquente consiste à mettre en place un instrument innovant de référence (« gold standard »), appelé RheoSpectris, dédié à la mesure de la viscoélasticité hyper-fréquence (entre 10 Hz et 1000 Hz) des matériaux et biomatériaux. Cet outil est indispensable pour valider et calibrer toute nouvelle technique d’élastographie dynamique. Une étude comparative entre RheoSpectris et la rhéométrie classique est réalisée afin de valider des mesures faites sur différents matériaux (silicone, thermoplastique, biomatériaux, gel). L’excellente concordance entre les deux technologies permet de conclure que RheoSpectris est un instrument fiable pour la mesure mécanique à des fréquences difficilement accessibles par les outils actuels. Les bases théoriques d’une nouvelle modalité d’imagerie élastographique, nommée SWIRE (« shear wave induced resonance dynamic elastography »), sont présentées et validées sur des fantômes vasculaires. Cette approche permet de caractériser les propriétés mécaniques d’une inclusion confinée (e.g. caillot sanguin) à partir de sa résonance (amplification du déplacement) produite par la propagation d’ondes de cisaillement judicieusement orientées. SWIRE a également l’avantage d’amplifier l’amplitude de vibration à l’intérieur de l’hétérogénéité afin de faciliter sa détection et sa segmentation. Finalement, la méthode DVT-SWIRE (« Deep venous thrombosis – SWIRE ») est adaptée à la caractérisation de l’élasticité quantitative de thromboses veineuses pour une utilisation en clinique. Cette méthode exploite la première fréquence de résonance mesurée dans la thrombose lors de la propagation d’ondes de cisaillement planes (vibration d’une plaque externe) ou cylindriques (simulation de la force de radiation par génération supersonique). DVT-SWIRE est appliquée sur des fantômes simulant une TVP et les résultats sont comparés à ceux donnés par l’instrument de référence RheoSpectris. Cette méthode est également utilisée avec succès dans une étude ex vivo pour l’évaluation de l’élasticité de thromboses porcines explantées après avoir été induites in vivo par chirurgie. / The venous thromboembolism such as the lower limb deep venous thrombosis (DVT) is a vascular pathology characterized by a blood clot formation that induces partial or total vessel lumen occlusion. Pulmonary embolism is a fatal complication of DVT where the clot detaches from the wall, circulates in the blood flow, and produces an obstruction of pulmonary arterial branches. The combination of clinical prediction rules (signs or symptoms) and blood tests (D-dimer testing) coupled to venous ultrasonography (i.e. compression ultrasonography, color Doppler) allows an accurate diagnosis of first DVT. Nevertheless, such clinical tools present poor results to detect recurrent thrombotic events. Then, in order to guide patients towards optimal therapy, the problem is no more to detect the presence of thrombus, but to evaluate its maturity and its age, which are correlated to their mechanical properties (e.g. elasticity, viscosity). The dynamic elastography (DE) has been recently proposed as a novel non-invasive imaging modality capable to characterize the quantitative mechanical properties of tissues. The DE is based on the analysis of acoustical parameters (i.e. velocity, attenuation, wave pattern) of low frequency (10-7000 Hz) shear waves propagating within the probed medium. Such shear waves generated by external vibration, or remotely using ultrasound beam focalisation (radiation force), were tracked using ultra-fast ultrasound or magnetic resonance imaging. A method based on DE and adapted to mechanical characterization of venous thrombosis may allow the quantification of diseases severity in order to improve the final diagnosis. This thesis presents the works related to the development and complete validation of a novel non-invasive elastography imaging method for the quantitative and reliable estimation of mechanical properties of venous thrombosis. In order to fulfil the main objective, it is first necessary to improve knowledge about mechanical behaviours of blood clot (coagulated blood) subjected to a dynamic solicitation similar to DE. The shear storage (elastic behaviour, G’) and loss (viscous behavior, G’’) moduli of porcine blood clots are measured by DE during the blood coagulation kinetics (at 70 Hz) and after completely coagulation (between 50 Hz and 160 Hz). These results are the first dynamic behaviour measurements of blood clots in such wide frequency range. The subsequent step consists in introducing an innovative reference instrument (« gold standard »), called RheoSpectris, dedicated to measure the hyper-frequency viscoelasticity (between 10 Hz and 1000 Hz) of materials and biomaterials. This tool is indispensable to validate new dynamic elastography techniques. A comparative study between RheoSpectris and classical rheometry is performed to validate the measurements on different materials (silicon, thermoplastic, biomaterials, gel). The excellent agreement between both technologies allows to conclude that RheoSpectris is a reliable instrument for mechanical measurements at high frequencies, which is not always possible with current tools. The theoretical basis of a novel elastographic imaging modality, labelled SWIRE (« shear wave induced resonance dynamic elastography ») is presented and validated on vascular phantoms. Such approach allows the characterization of mechanical properties of a confined inclusion (e.g. blood clot) from its resonance (displacement amplification) due to the propagation of judiciously oriented shear waves. SWIRE has also the advantage to amplify the vibration amplitude within the heterogeneity to help for its detection and segmentation. Finally, the method DVT-SWIRE ((« Deep venous thrombosis – SWIRE ») is adapted to the quantitative elasticity estimation of venous thrombosis in the context of clinical use. DVT-SWIRE exploits the first resonance frequency measured within the thrombosis during the plane (vibration of rigid plate) or cylindrical (simulating supersonic radiation force generation) shear waves propagation. The technique is applied on DVT phantoms and the results are compared to those given by the RheoSpectris reference instrument. This method is also used successfully in an ex vivo study for the elasticity assessment of explanted porcine thrombosis surgically induced in vivo.

Page generated in 0.1111 seconds