• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 114
  • 106
  • 29
  • 18
  • 14
  • 10
  • 9
  • 7
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 381
  • 53
  • 51
  • 48
  • 40
  • 39
  • 37
  • 37
  • 36
  • 35
  • 34
  • 33
  • 32
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Avaliação da microdureza superficial da resina composta fotopolimerizada por aparelho de luz halógena e de diodo(LED) em função de opacidade e ação do flúor fosfato acidulado /

Firoozmand, Leily Macedo. January 2005 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Maria Amélia Máximo de Araújo / Banca: Maria Antonia Pereira / Banca: João Carlos da Rocha / Resumo: O objetivo deste trabalho foi verificar a influência da opacidade de cor, tipos de aparelhos fotopolimerizadores (luz halogena X led azul) e aplicação tópica do FFA 1,23% na microdureza da resina composta. A resina composta Esthet-X (Dentisply), nas cores A2 e A2-O foram inseridas em uma matriz de aço-inoxidável em cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halogena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 4 grupos com trinta amostras, sendo analisadas a superfície e a base das amostras. Estas foram armazenadas em água destilada, por 24h e posteriormente embutidas em RAAQ. Realizou-se a leitura da microdureza inicial em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. A seguir, foi aplicado o FFA 1,23% por 48 min e uma segunda leitura da microdureza foi realizada. O teste estatístico de ANOVA e Tukey (5%) demonstrou que a microdureza da superfície foi sempre maior que a da base. O aparelho de luz halógena apresentou maiores valores médios de microdureza da resina (57,61 HV) que o aparelho de LED (42,53 HV). Foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade, a resina A2-O apresentou os menores valores. A aplicação do FFA 1,23% promoveu menores valores de microdureza na resina. A opacidade da resina composta, o tipo e fonte polimerizadora, bem como a utilização tópica do FFA 1,23% influenciam no grau de microdureza resina. / Abstract: The aim of this study was to verify the influence of resin opacity, light curing units (halogen light X blue LED) and topic application of 1.23% acidulated phosphate fluoride (APF) on the resin hardness. The composite resin Esthet-X (Dentsply), shade A2 and A2-O was put in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a halogen light curing unit, XL 3000 (3M) or a blue LED unit, Optilight LD II (Gnatus), for 40s. Four groups with thirty samples were separated and the top and bottom of samples were analyzed. They were stored for 24h and afterwords, built-in acrylic resin. Vickers hardness measurements were made in Vickers Digital Microhardmeter, using 50g load and 30s time. The APF 1.23% was applied for 48 min and a second hardness measurement was done. Statistic test ANOVA and Tukey (5%) demonstrated that top hardness were always higher than bottom. The halogen unit presented higher hardness values (57.61 HV) than LED unit (42.53 HV). Significant differences were found between the hardness values when the opacity was varied, and depth wise the A2-O resin presented the lowest values. The use of 1.23% APF on the resin resulted in the lowest values of hardness. The resin opacity, the light curing unit and the use of 1.23% APF have all influence on the resin hardness. / Mestre
312

Misturas cinza volante e cal de carbureto : comportamento da resistência à compressão simples para cura acelerada

Saldanha, Rodrigo Beck January 2014 (has links)
A questão ambiental vem se tornando tema recorrente nos foros nacionais e internacionais, estando atualmente inserida na opinião pública, nas comunidades e sendo norteadora na geração de novos produtos e serviços na área industrial e comercial voltados para a sustentabilidade. Neste sentido, a indústria da construção é um dos principais causadores de impacto ambiental, pois consome consideráveis recursos naturais e gera grandes quantidades de resíduos. Sendo assim, a utilização de resíduos como matéria prima na indústria da construção possibilita benefícios ambientais e econômicos. Buscando avançar nesta discussão, a presente pesquisa procurou inserir dois resíduos (cinza volante e cal de carbureto), gerados na região metropolitana de Porto Alegre, como possibilidade de solução de Engenharia. Para isto, é necessário um estudo do seu comportamento mecânico decorrente da cimentação proporcionada pela mistura e compactação destes materiais. Contudo, ainda não existe uma formulação de dosagem dessa mistura baseadas em critérios mais racionais. Assim, a presente pesquisa busca fornecer subsídios para que, através do uso da relação porosidade/teor volumétrico de cal obtidas a partir da identificação e quantificação das variáveis mais importantes no controle da resistência da mistura de dois resíduos, possa determinar o seu comportamento. Isto é, a formulação de equações para previsão da resistência à compressão simples do material cimentado em cura acelerada. Para isso, foram realizados ensaios de compressão simples em corpos-de-prova com 5, 10 e 15% de cal, com peso específico aparente seco de 11, 12 e 13 kN/m³; curados por 1, 3 e 7 dias em câmara vaporizadora nas temperaturas 40, 60 e 80°C; e 3, 7 e 14 dias para cura sem vapor a 23°C. Os resultados demonstram que o aumento da quantidade de cal, do peso específico aparente seco, do tempo de cura e da temperatura provoca o aumento da resistência à compressão simples da mistura compactada. Entretanto, a temperatura apresentou um limite de influência para 3 e 7 dias, onde a variação de 60°C para 80°C não aumentou a resistência. A relação porosidade(/teor volumétrico de cal (Lv), ajustado por um expoente [/(Lv)0,11], mostrou-se adequado na formulação de equações na previsão da resistência do material cimentado para todas as temperaturas e tempos de cura estudadas. Além disso, a existência de relações únicas e distintas no controle da resistência à compressão simples em função da porosidade, teor volumétrico de cal e temperatura, assim como para o tempo de cura mostraram-se úteis para formulações de dosagem. Os resultados foram submetidos à análise de variância que comprovou que todos os fatores controláveis escolhidos para o experimento são significativos, assim como todas as interações entre eles. / The environmental issue is becoming a recurring theme in national and international forums, currently inserted in the public opinion, communities and being guiding the generation of new products and services in the industrial and commercial area focused to sustainability. In this sense, the construction industry is a major cause of environmental impact, it consumes considerable natural resources and generates large amounts of waste. Thus, the use of waste as a raw material in the construction industry provides economic and environmental benefits. Looking for progress in this discussion, this research sought to insert two wastes (fly ash and carbide lime), generated in the metropolitan region of Porto Alegre, as a possibility for solution of Engineering. For this, a study of its mechanical behavior due to cementation and compaction provided by the mixture of these materials is necessary. However there is not a rational dosage formulation of this mixture. Therefore, this research seeks to provide subsidy to determine behavior through the use of the relation of porosity/volumetric lime content obtained from the identification and quantification of the most important variables in the controlling of strength to the mixture of two residues. That is, the formulation of equations for predicting the compressive strength of cemented material into accelerated healing. For this, tests were conducted on samples with 5, 10 and 15% of lime; with dry unit weight of 11, 12 and 13 kN/m³; for 1, 3 and 7 curing days with steam in the temperature of 40, 60 and 80°C; and 3, 7 and 14 days without steam for 23°C. The results show that increasing the amount of carbide lime, dry unit weight, curing time and temperature has as consequence the increase of unconfined compression strength of the compacted mixture. However, the temperature had a limit of influence for 3 and 7 days, where the range of 60°C to 80°C did not increase the unconfined compression strength. The porosity()/volumetric lime content (Lv) ratio adjusted by an exponent [/(Lv)0,11], proved to be adequate to formulate equations to predict the strength of the cemented material for all temperatures and curing times studied. Furthermore, the existence of unique and distinct relationships in the control of unconfined compression strength of the mixture studied as a function of porosity, lime volumetric content, temperature, as for the cure time proved to be useful in dosage formulations. The results were subjected to analysis of variance showing that all the controllable factors chosen for the experiment are significant, as well as all interactions between them.
313

Comportamento clínico de restaurações classe I e II de resina composta realizadas com sistema adesivo universal em diferentes protocolos de aplicação - estudo clínico randomizado / Clinical performance of composite resin vlass I and II conducted with a universal adhesive system in different application protocols - randomized clinical study

Carvalho, Andreia Assis 20 April 2018 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-05-22T17:33:36Z No. of bitstreams: 2 Tese - Andreia Assis Carvalho - 2018.pdf: 4561805 bytes, checksum: 5562226572f75d161d963c396d0c974f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-05-23T11:38:00Z (GMT) No. of bitstreams: 2 Tese - Andreia Assis Carvalho - 2018.pdf: 4561805 bytes, checksum: 5562226572f75d161d963c396d0c974f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-23T11:38:00Z (GMT). No. of bitstreams: 2 Tese - Andreia Assis Carvalho - 2018.pdf: 4561805 bytes, checksum: 5562226572f75d161d963c396d0c974f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-04-20 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The objective of this study was to evaluate the clinical behavior of direct composite resin restorations (Class I and II), varying the universal dental adhesive application protocol, using the FDI and USPHS evaluation criteria. It was a randomized, double-blind, mouth5 divided, and sample-based randomized controlled trial. The selected participants should have a Class I and/or II restorative need for at least three dental elements or multiples of three resulting from the presence of carious lesions and/or unsatisfactory restorations. Three protocols for the application of the Single Bond Universal adhesive (3M ESPE) were tested (n=150): CAT (control) = etch-and-rinse + adhesive (n=50); CASE = selective etching in enamel + adhesive (n=50) and Ac = self-etch (n=50). The three groups were similarly restored using Filtek Z350 XT composite resin (3M ESPE) by means of the oblique incremental technique. Clinical evaluations were performed by two evaluators at the baseline (T1) and after 15.8 (±2.7 months) (T2), using the FDI and USPHS criteria. Friedman (between groups at different times), Wilcoxon (between times for each group) and McNemar (between FDI and USPHS criteria) were performed, α=0.05. The Kappa test showed excellent inter-examiner agreement (κ>0.80). For the "superficial staining" property, a statistically significant difference was observed in T2 between the CAT and CASE groups (p=0.01) with higher values for CAT and, when T1 and T2 were compared for each group, there were differences in the CAT group (p=0.001) and in the Ac group (p=0.007) for T2. For the other comparisons between groups and times there were no statistically significant differences, even when the FDI and USPHS criteria were compared (p≥0.05). It can be concluded that the different protocols of universal adhesive application (CAT, CASE and Ac) did not influence the clinical behavior of the restorations evaluated in 15.8 months of evaluation. The FDI and USPHS criteria provided comparable results. / Esse trabalho objetivou avaliar o comportamento clínico de restaurações diretas de resina composta (Classe I e II), variando o protocolo de aplicação do adesivo dentário universal, por meio dos critérios de avaliação FDI e USPHS. Trata-se de um ensaio clínico contrlado randomizado, duplo-cego, boca-dividida e de amostra por conveniência. Os participantes selecionados deveriam ter necessidade restauradora de Classe I e/ou II no mínimo em três elementos dentários ou múltiplos de três, resultantes da presença de lesões cariosas e/ou restaurações insatisfatórias. Três protocolos de aplicação do adesivo Single Bond Universal (3M ESPE) foram testados (n=150): CAT (controle) = Condicionamento ácido total + adesivo (n=50); CASE = Condicionamento ácido seletivo em esmalte + adesivo (n=50) e Ac = autocondicionante (n=50). Os três grupos foram restaurados de forma similar utilizando resina composta Filtek Z350 XT (3M ESPE) por meio da técnica incremental oblíqua. As avaliações clínicas foram realizadas por dois avaliadores no baseline (T1) e após 15,8 (±2,7 meses) (T2), por meio dos critérios FDI e USPHS. Foram realizados os testes Friedman (entre os grupos nos diferentes tempos), Wilcoxon (entre os tempos para cada grupo) e McNemar (entre os critérios FDI e USPHS), α=0,05. O teste Kappa apresentou excelente concordância interexaminadores (κ>0,80). Para a propriedade “manchamento superficial”, observou-se diferença estatisticamente significante no T2 entre os grupos CAT e CASE (p=0,01) com maiores valores para CAT e, quando comparados T1 e T2 para cada grupo, houve diferença no grupo CAT (p=0,001) e no grupo Ac (p=0,007) para T2. Para as demais comparações entre os grupos e tempos não houve diferenças estatisticamente significantes, inclusive quando os critérios FDI e USPHS foram comparados (p≥0,05). Pode-se concluir que os diferentes protocolos de aplicação do adesivo universal (CAT, CASE e Ac) não influenciaram o comportamento clínico das restaurações avaliadas em 15,8 meses de avaliação. Os critérios FDI e USPHS proporcionaram resultados comparáveis entre si.
314

Misturas cinza volante e cal de carbureto : comportamento da resistência à compressão simples para cura acelerada

Saldanha, Rodrigo Beck January 2014 (has links)
A questão ambiental vem se tornando tema recorrente nos foros nacionais e internacionais, estando atualmente inserida na opinião pública, nas comunidades e sendo norteadora na geração de novos produtos e serviços na área industrial e comercial voltados para a sustentabilidade. Neste sentido, a indústria da construção é um dos principais causadores de impacto ambiental, pois consome consideráveis recursos naturais e gera grandes quantidades de resíduos. Sendo assim, a utilização de resíduos como matéria prima na indústria da construção possibilita benefícios ambientais e econômicos. Buscando avançar nesta discussão, a presente pesquisa procurou inserir dois resíduos (cinza volante e cal de carbureto), gerados na região metropolitana de Porto Alegre, como possibilidade de solução de Engenharia. Para isto, é necessário um estudo do seu comportamento mecânico decorrente da cimentação proporcionada pela mistura e compactação destes materiais. Contudo, ainda não existe uma formulação de dosagem dessa mistura baseadas em critérios mais racionais. Assim, a presente pesquisa busca fornecer subsídios para que, através do uso da relação porosidade/teor volumétrico de cal obtidas a partir da identificação e quantificação das variáveis mais importantes no controle da resistência da mistura de dois resíduos, possa determinar o seu comportamento. Isto é, a formulação de equações para previsão da resistência à compressão simples do material cimentado em cura acelerada. Para isso, foram realizados ensaios de compressão simples em corpos-de-prova com 5, 10 e 15% de cal, com peso específico aparente seco de 11, 12 e 13 kN/m³; curados por 1, 3 e 7 dias em câmara vaporizadora nas temperaturas 40, 60 e 80°C; e 3, 7 e 14 dias para cura sem vapor a 23°C. Os resultados demonstram que o aumento da quantidade de cal, do peso específico aparente seco, do tempo de cura e da temperatura provoca o aumento da resistência à compressão simples da mistura compactada. Entretanto, a temperatura apresentou um limite de influência para 3 e 7 dias, onde a variação de 60°C para 80°C não aumentou a resistência. A relação porosidade(/teor volumétrico de cal (Lv), ajustado por um expoente [/(Lv)0,11], mostrou-se adequado na formulação de equações na previsão da resistência do material cimentado para todas as temperaturas e tempos de cura estudadas. Além disso, a existência de relações únicas e distintas no controle da resistência à compressão simples em função da porosidade, teor volumétrico de cal e temperatura, assim como para o tempo de cura mostraram-se úteis para formulações de dosagem. Os resultados foram submetidos à análise de variância que comprovou que todos os fatores controláveis escolhidos para o experimento são significativos, assim como todas as interações entre eles. / The environmental issue is becoming a recurring theme in national and international forums, currently inserted in the public opinion, communities and being guiding the generation of new products and services in the industrial and commercial area focused to sustainability. In this sense, the construction industry is a major cause of environmental impact, it consumes considerable natural resources and generates large amounts of waste. Thus, the use of waste as a raw material in the construction industry provides economic and environmental benefits. Looking for progress in this discussion, this research sought to insert two wastes (fly ash and carbide lime), generated in the metropolitan region of Porto Alegre, as a possibility for solution of Engineering. For this, a study of its mechanical behavior due to cementation and compaction provided by the mixture of these materials is necessary. However there is not a rational dosage formulation of this mixture. Therefore, this research seeks to provide subsidy to determine behavior through the use of the relation of porosity/volumetric lime content obtained from the identification and quantification of the most important variables in the controlling of strength to the mixture of two residues. That is, the formulation of equations for predicting the compressive strength of cemented material into accelerated healing. For this, tests were conducted on samples with 5, 10 and 15% of lime; with dry unit weight of 11, 12 and 13 kN/m³; for 1, 3 and 7 curing days with steam in the temperature of 40, 60 and 80°C; and 3, 7 and 14 days without steam for 23°C. The results show that increasing the amount of carbide lime, dry unit weight, curing time and temperature has as consequence the increase of unconfined compression strength of the compacted mixture. However, the temperature had a limit of influence for 3 and 7 days, where the range of 60°C to 80°C did not increase the unconfined compression strength. The porosity()/volumetric lime content (Lv) ratio adjusted by an exponent [/(Lv)0,11], proved to be adequate to formulate equations to predict the strength of the cemented material for all temperatures and curing times studied. Furthermore, the existence of unique and distinct relationships in the control of unconfined compression strength of the mixture studied as a function of porosity, lime volumetric content, temperature, as for the cure time proved to be useful in dosage formulations. The results were subjected to analysis of variance showing that all the controllable factors chosen for the experiment are significant, as well as all interactions between them.
315

Cura e propriedades físicas de bulbos de Amarílis (Hippeastrum x hybridum Hort.) / Curing and physical properties of Hippeastrum bulbs

Martins, Marcelo Luis 16 August 2018 (has links)
Orientador: Sylvio Luis Honório / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-16T03:54:41Z (GMT). No. of bitstreams: 1 Martins_MarceloLuis_M.pdf: 770308 bytes, checksum: 481ff6a7c14306c173ede0d4ee971464 (MD5) Previous issue date: 2010 / Resumo: Com a finalidade de determinar algumas características físicas e químicas do Hippeastrum hybridus da variedade Apple Blossom durante o armazenamento foi conduzido este experimento na faculdade de Engenharia Agrícola - UNICAMP. O experimento foi realizado no mês de agosto do ano de 2008 em virtude da época de colheita do bulbo. Apos a coleta do material uma parcela dos bulbos foi impactada, todas as parcelas foram curadas até que perdessem cerca de 15% de matéria fresca. Após este tratamento os bulbos foram divididos entre aqueles que foram impactados e os não impactados, ambas as parcelas foram colocadas sob refrigeração a 13ºC durante 3 meses, uma parcela do material não impactado foi mantido a temperatura de 25±3 durante o mesmo período para efeito de comparação. Foram realizadas analises físico-químicas e visuais antes de depois dos tratamentos, e a cada 10 dias durante todo o período de armazenagem a frio do material. Acompanharam-se as alterações físico-químicas, mediante avaliação dos parâmetros, sólidos solúveis, altura, circunferência. A aparência geral do bulbo também foi acompanhada pela presença ou não de vermelhidão por impacto. Os bulbos submetidos ao ensaio de volume apresentaram volume médio igual a 495cm³ com coeficiente de variação igual a 0, 028%, o volume aparente possui valor igual 95,625 kg, a massa específica aparente 0, 617cm³, e o volume intersticial determinado foi igual a 174cm³. A massa específica real possui valor igual a 0,834g/cm³.Os bulbos submetidos à pesagem apresentaram massa média de valor igual a 413g com coeficiente de variação igual a 0,28%, a porosidade equivalente a 27%. Os valores dos coeficientes de variação demonstram que os bulbos apresentaram boa uniformidade de volume e massa e baixa porosidade na massa. Os resultados das analises realizadas permitiram avaliar que os bulbos impactados e mantidos sob refrigeração não apresentam diferenças significativas em nível de significância de 5% para o parâmetro de sólidos solúveis quando comparados aos bulbos não impactados sob mesma condição climática. Entretanto o bulbo colocado fora da refrigeração apresentou diferença significativa em nível de significância de 5% para o parâmetro de lidos solúveis quando comparado ao bulbo não impactado e sob refrigeração. O bulbo é um esferóide oblato com 90,8% de esferificidade / Abstract: It was developed a research to determinate some physical and chemical characteristics of Hippeastrum hybridus (Apple Blossom variety) during storage, the experimental tests were conducted on the UNICAMP lab. The experiment tests were carried out in august, 2008 because of the harvest season of the bulbs. After the harvest part of the material were impacted and the whole material were separated in portions and then received the curing treatment with hot air at 30ºC for twenty four hours making the bulbs lose about 15% of water.After curing treatment the material were divided on "impacted" and "non impacted" both portions were stored for 3 months on 13ºC, one portion didn't receive the cold treatment. After that, some physical and chemical analyses were conducted, a visual analysis was made as well, and the analyses started 10 days after the product was impacted. The following parameters were evaluated: moisture content, soluble solids (ºBRIX), weight, circumference and general appearance. The statistical analysis results showed that the impact did not affect the bulbs soluble solids but the cold chain affects them. In matters of volume the bulbs showed medium volume equal to 495cm³, the variation about 0, 028%, the apparent volume 95,625 kg , specific mass apparent 0, 617cm³ and the interstitial volume equal to 174cm³, the specific real mass it's equal to 0,834g/cm³, porosity it's equal to 27%. The bulb is an oblate spheroid with 90, 8% of sphericity / Mestrado / Tecnologia Pós-Colheita / Mestre em Engenharia Agrícola
316

Contribuição aos estudos da influência da nanossílica nas propriedades mecânicas e na trabalhabilidade de concretos para produção em centrais e para fabricação de pré-moldados / Contribution to the studies of the influence of nanosilica on the mechanical properties and workability of concretes for batching plants and for manufacture of precast pieces

Moraes, Mayara Queiroz 11 December 2012 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-10-21T20:50:08Z No. of bitstreams: 2 Dissertação - Mayara Queiroz Moraes - 2012.pdf: 2306074 bytes, checksum: 39f99dfabbb79296b809313dd0730f16 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-22T19:07:28Z (GMT) No. of bitstreams: 2 Dissertação - Mayara Queiroz Moraes - 2012.pdf: 2306074 bytes, checksum: 39f99dfabbb79296b809313dd0730f16 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-22T19:07:28Z (GMT). No. of bitstreams: 2 Dissertação - Mayara Queiroz Moraes - 2012.pdf: 2306074 bytes, checksum: 39f99dfabbb79296b809313dd0730f16 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2012-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Unlike the silica fume, whose benefits on the properties of the concretes are already widely known, little is known regarding nanosilica. This research offers an analysis of the contribution of different types of nanosilica in mechanical characteristics and workability maintenance of concretes, as well as an evaluation of the behavior of these additions when subjected to steam curing. For this, there were compared among themselves laboratory test results in concretes with different characteristics and different purposes (one of them suitable for production at batching plants and the other for metering precast elements). The results confirmed advantages for the simple addition of nanossílica at mechanical properties of concretes for batching plants with strengths above 40 MPa (a/c<0.52), but showed that the most advantageous situation consists in adding it together with sílica fume, since the concrete with both additions exceeded the reference concrete above 36 MPa (a/c<0.615), which highlights the importance of combining pozzolanic effect of silica fume, the creation of nucleation sites caused by nanossílica and better packaging mix, size distribution generated by the two additions give the folder.Regarding the maintenance of workability, the nanosilica dispersed in superplasticizer demonstrated satisfactory performance. In the analysis of concretes for precast elements, the addition of nanosilica dispersed superplasticizer and silica fume together was also the one which showed the best results in terms of resistance in 28 days of conventional curing. However, with steam curing, a great improvement was noted in the behavior of nanosilica dispersed in water, which had not achieved good results with the conventional cure, while nanosilica dispersed in superplasticizer did not respond well to the process, possibly due to the shape of the polycarboxylate used in the dispersion of the particles. Probably, the nanosilica dispersed in water showed no significant pozzolanic activity levels, but with the rise of temperature and the agitation of the particles, the formation of nucleation sites was intensified. As the development of resistance in early ages, all additions had positive effects, but the best performance was observed on the concrete with the simple addition of nanosilica dispersed in superplasticizer. With this addition, the concrete has reached 40 MPa after only 12 hours of steam curing, within about four times lower than the reference concrete (44 hours), which suggests that its addition to the concrete could result in na almost four times greater productivity of a precast elements factory. / Ao contrário da sílica ativa, cujas vantagens nas propriedades do concreto já são amplamente conhecidas, pouco se sabe em relação à nanossílica. Esta pesquisa contempla uma análise da contribuição de diferentes tipos de nanossílica nas características mecânicas e de manutenção do abatimento de concretos, bem como uma avaliação do comportamento destas adições frente à cura térmica. Para isto, compararam-se entre si resultados de ensaios laboratoriais em concretos com diferentes traços e diferentes finalidades (produção em centrais dosadoras e fabricação de pré-moldados). Os resultados confirmaram vantagens para a adição simples de nanossílica quanto à resistência à compressão dos concretos para centrais com resistências acima de 40 MPa (a/c<0,52), mas mostraram que a melhor situação consiste na adição conjunta de sílica ativa e nanossílica, já que o concreto com a adição conjunta superou o de referência a partir de 36 MPa (a/c<0,615). Isso deixa clara a importância de aliar o efeito pozolânico da sílica ativa, a criação de pontos de nucleação ocasionada pela nanossílica e o melhor empacotamento da mistura, gerado pela distribuição granulométrica que as duas adições juntas conferem à pasta. Quanto à manutenção do abatimento, a nanossílica dispersa em aditivo superplastificante demonstrou desempenho satisfatório. Em relação aos concretos para pré-moldados, foi a adição conjunta de sílica ativa e nanossílica dispersa em superplastificante a que apresentou melhores resultados de resistência aos 28 dias de cura convencional. No entanto, com a cura térmica, notou-se melhora substancial do comportamento da nanossílica dispersa em água, que não havia atingido bons resultados com cura convencional, enquanto a nanossílica dispersa em superplastificante não respondeu bem ao processo, possivelmente por influência da forma do policarboxilato usado na dispersão das partículas. Provavelmente, a nanossílica dispersa em água não apresentou atividade pozolânica relevante, mas com a elevação da temperatura e a agitação das partículas, a formação de pontos de nucleação foi intensificada. Quanto ao desenvolvimento de resistências nas idades iniciais, todas as adições apresentaram efeitos positivos, mas o melhor desempenho foi observado no concreto com adição simples da nanossílica dispersa em superplastificante. Com ela, o concreto atingiu 40 MPa com apenas 12 horas de cura térmica, prazo quase quatro vezes menor do que o do concreto de referência (44 horas), o que leva a crer que sua adição ao concreto poderia implicar em uma produtividade quase quatro vezes maior de uma fábrica de elementos pré-moldados.
317

Efeito do pré-aquecimento e da pós-polimerização nas propriedades mecânicas e grau de conversão de um compósito experimental reforçado com fibra de vidro / Effect of pre-heating and post-curing on mechanical properties and degree of conversion of an experimental composite reinforced with glass fiber

Almeida, Letícia Nunes de 25 February 2016 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2016-09-21T13:42:33Z No. of bitstreams: 2 Dissertação - Letícia Nunes de Almeida - 2016.pdf: 4956536 bytes, checksum: ff3b7edcf1cb8b45c40f2292cb032676 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-09-21T13:45:21Z (GMT) No. of bitstreams: 2 Dissertação - Letícia Nunes de Almeida - 2016.pdf: 4956536 bytes, checksum: ff3b7edcf1cb8b45c40f2292cb032676 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-09-21T13:45:21Z (GMT). No. of bitstreams: 2 Dissertação - Letícia Nunes de Almeida - 2016.pdf: 4956536 bytes, checksum: ff3b7edcf1cb8b45c40f2292cb032676 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The pre-heating and post-curing can improve the mechanical properties of composites, even though there be no studies of fiber reinforced composites. The aim of this study was to evaluate the effect of pre-heating and post-curing autoclave and microwave in flexural strength (FS), diametral tensile strength (DTS), knoop microhardness (KHN) and degree of conversion (DC) of a experimental fiber- reinfoced composite. The experimental material was prepared with 30% glass fibers (3 mm), 22.5% of the resin matrix (40/60 Bis-GMA / TEGDMA) and 47.5% barium silicate particles. Six experimental groups were created by the interaction between the factors under study: heating, on two levels (without heating and heating at 60°C) and post-curing in 3 levels (conventional curing without post-curing, autoclave (120°C for 15 minutes) and microwaves (540 W for 5 minutes) The groups were: F - curing at 1500 mW/cm2 for 40 seconds; F + M - curing and post- polymerization in microwave; F + A - curing and post-curing in an autoclave , AQ + F - the composite heating prior to curing, AQ + F + M - heating prior to curing and post-curing in microwave;. AQ + F + A - heating prior to curing and post-curing and autoclave heating was conducted digital oven for 5 minutes at 60°C. Ten samples of the RF dimensions 25 x 2 x 2 mm and DTS in dimensions of 3 x 6 mm were tested in a universal testing machine Instron 5965, 0.5 mm/min. the KHN test was performed on samples of 3 x 6 mm with a load of 50 g for 30 sec, totaling 50 indentations per group. GC was obtained by Spectroscopy Fourier Transform Infrared (FTIR) on 5 samples. Data were analyzed by a factorial 2x3 and general linear model ANOVA and Tukey tests (α = 0.05). Factor analysis showed significant interaction between the factors just for RTD (p = 0.0001); preheating was significant factor for RF (p = 0.0001), RTD (p = 0.020) and KHN (p = 0.0001); post-curing factor for KHN was significant (p = 0.0001). ANOVA and Tukey tests showed statistically significant differences between groups for DTS (p = 0.001: AQ + F ≥ AQ + F + M = F + A = AQ + F + A = F + M ≥ F), FS (p = 0.016: AQ + F + M ≥ AQ + F + A + F = AQ = AQ + A + M ≥ F ≥ F) and KHN (p = 0.0001: AQ + F + M ≥ AQ + A + F = F = F + A + M ≥ F ≥ M + AQ). GC results showed no statistically significant difference. Through the Pearson correlation coefficient was observed significant positive correlation between the GC and RTD (r = 0.473, p = 0.008) and between DTS and FS (r = 0.263, p = 0.042). The pre-heating and post- polymerization were shown to be favorable to promote better mechanical properties of fiber reinforced composite by studied, specific for each property being analyzed. / O aquecimento prévio à polimerização e a pós-polimerização podem melhorar propriedades mecânicas em compósitos, embora inexistam estudos em compósitos reforçados com fibra. O objetivo deste estudo foi avaliar o efeito do pré- aquecimento e da pós-polimerização em autoclave e microondas na resistência flexural (RF), resistência à tração diametral (RTD), microdureza knoop (KHN) e grau de conversão (GC) de um compósito experimental reforçado por fibra de vidro. O material experimental foi confeccionado com 30% de fibras de vidro (3 mm), 22,5% de matriz resinosa (40/60 Bis-GMA/TEGDMA) e 47,5% de partículas de silicato de bário. Seis grupos experimentais foram criados pela interação entre os fatores em estudo: aquecimento, em dois níveis (controle sem aquecimento e aquecimento a 60oC) e pós-polimerização, em 3 níveis (fotopolimerização convencional sem pós- polimerização, autoclave (120oC por 15 minutos) e microondas (540 W por 5 minutos). Os grupos foram: F - fotopolimerização à 1500 mW/cm2 por 40 segundos; F+M - fotopolimerização e pós- polimerização em microondas; F+A - fotopolimerizacão e pós-polimerização em autoclave; AQ+F - aquecimento do compósito previamente à fotopolimerização; AQ+F+M - aquecimento previamente à fotopolimerização e pós-polimerização em microondas; AQ+F+A - aquecimento previamente à fotopolimerização e pós-polimerização e autoclave. O aquecimento foi realizado em estufa digital por 5 minutos a 60oC. Dez amostras de RF nas dimensões de 25 x 2 x 2 mm e de RTD nas dimensões de 3 x 6 mm foram testadas em máquina de ensaio universal Instron 5965, a 0,5mm/min. O teste de KHN foi realizado em amostras de 3 x 6 mm com carga de 50 g por 30 s, totalizando 50 indentações por grupo. O GC foi obtido através de Espectroscopia de Infravermelho por Transformada de Fourrier (FTIR) em cinco amostras. Os dados foram analisados por um modelo linear geral fatorial 2x3 e testes de ANOVA e Tukey (α=0,05). A análise fatorial mostrou interação significativa entre os fatores apenas para RTD (p=0,0001); o fator pré-aquecimento foi significante para RF (p=0,0001), RTD (p=0,020) e KHN (p=0,0001); o fator pós-polimerização foi significante para KHN (p=0,0001). Os testes de ANOVA e Tukey mostraram diferença estatística entre os grupos para RTD (p = 0,001: AQ+F ≥ AQ+F+M = F+A = AQ+F+A = F+M ≥ F), RF (p = 0,016: AQ+F+M ≥ AQ+F+A = AQ+F = AQ+A ≥ F+M ≥ F) e KHN (p = 0,0001: AQ+F+M ≥ AQ+F+A = F+A= F+M ≥ AQ+F ≥ F). Os resultados de GC não apresentaram diferença estatisticamente significante. Através do coeficiente de correlação de Pearson foi possível observar correlação positiva significante entre o GC e RTD (r = 0,473, p = 0,008) e entre RTD e RF (r = 0,263, p = 0,042) . O pré- aquecimento e a pós-polimerização mostraram-se favoráveis para promover melhores propriedades mecânicas do compósito reforçado por fibra estudado, sendo específicos para cada propriedade analisada.
318

Avaliação da formação e degradação de filmes de vernizes curados por radiação ultravioleta e feixe de elétrons e expostos ao envelhecimento acelerado / Evaluation of parameters associated with UV/EB cured clearcoats degradation used in outdoor environment

Carmen Silvia Bentivoglio Ruiz 24 June 2003 (has links)
Os revestimentos curáveis por radiação ultravioleta (UV) ou feixe de elétrons (EB) são sistemas líquidos reativos compostos por resinas, diluentes (monômero) e aditivos, capazes de formar compostos poliméricos termorrígidos por reações de polimerização e reticulação induzidas por radiação. Esta tecnologia tem sido empregada como alternativa aos processos convencionais no desenvolvimento de uma variada gama de produtos. Um dos grandes desafios da aplicação da tecnologia de cura UV/EB em produtos a serem submetidos ao intemperismo é a manutenção de suas propriedades físicas e de sua aparência. Este trabalho apresenta informações sobre o comportamento de quatro vernizes com e sem aditivos estabilizantes à luz-curados por radiação UV ou EB quando submetidos ao processo de envelhecimento acelerado. Os vernizes foram caracterizados por técnicas termoanalíticas como termogravimetria (TG), calorimetria exploratória diferencial (DSC) e fotocalorimetria diferencial (foto-DSC); espectroscopia de absorção no infravermelho e no ultravioleta, e propriedades mecânicas. Os vernizes sob a forma de filmes de 50 &#181;m de espessura foram curados com diferentes doses de radiação UV ou EB. A cura por radiação UV foi conduzida em túnel de luz, provido de uma lâmpada de mercúrio de média pressão e esteira rolante com velocidade variável. As diferentes doses de radiação UV de 50 a 1500 mJ cm-2 foram obtidas variando-se a velocidade da esteira. A cura por EB foi realizada utilizando-se acelerador de elétrons de energia de 1,5 MeV, sob atmosfera de nitrogênio, aplicando-se doses no intervalo de 1,6 a 300 kGy. O grau de cura dos diferentes filmes foi calculado por meio dos valores das entalpias de reação da cura residual obtidos por DSC. Os testes de envelhecimento acelerado dos filmes curados foram feitos em câmara de envelhecimento do tipo Weather-Ometer por períodos de exposição de 100 a 3000 horas. Os dados obtidos experimentalmente foram avaliados em função da composição dos vernizes, da dose e do tipo de radiação empregada na cura e do tempo de permanência na câmara de envelhecimento. Os resultados indicam que os filmes curados por EB apresentam maior durabilidade frente ao intemperismo do que os seus pares curados por radiação UV. Os filmes não estabilizados (sem aditivos) apresentam grande instabilidade nas condições do teste de envelhecimento. O efeito do envelhecimento foi observado por meio de dados de dureza, brilho, rugosidade, índice de amarelecimento e alteração das bandas de absorção dos espectros FTIR. / The materials curable by ultraviolet (UV) or electron beam (EB) radiation such as inks, adhesives and coatings are reactive compounds made up of resin, monomer, photoinitiator and additives which undergo polymerization and crosslinking under irradiation producing thermoset products. This technology has been used in a great variety of industrial applications, replacing the conventional curing process in the development of new products. One of the challenging applications has been to design weatherable radiation cured coating which maintain their desirable physical properties and aesthetic appearance. This research reports information about the behavior of four UV and EB curable clear coatings -with or without light stabilizer additives- under accelerated weathering. Thermogravinietry, differential scanning calorimetry, differential photocalorimetry, infrared and ultraviolet spectroscopy and tensile properties were used to evaluate these formulations. Clear coating 50 &#181;m thick films were cured with UV and EB radiation at different doses. The UV curing process was carried out at room temperature using an UV tunnel, with a medium pressure mercury lamp and a transport belt with variable speed. The ultraviolet radiation doses were in the range of 50 to 1500 mJ cm-2. The EB curing process was performed under N2 atmosphere, with doses in the range from 1,6 to 300 kGy using the IPEN-CNEN/SP Dynamitron electron beam accelerator with energy of 1.5 MeV. The cure degree was determined by means of the residual reaction heat of the undercured samples obtained from photo-DSC or DSC measurements. The accelerated aging tests were carried out using a Weather-Ometer chamber with exposition times in the range of 100 to 3000 hours. The experimental data obtained from the photo-aged samples were evaluated and correlated to the formulation composition, type of radiation - UV or EB, radiation dose and residence time in the aging chamber. The results have shown that the EB cured films have a better resistance to photoinduced weathering effects than UV cured ones. UV/EB films with light stabilizers have shown larger stability than those counterparts with no additives. The aging effects were evaluated by parameters such as hardness, gloss, surface roughness, yellowness index and changes in the FTIR absorption bands.
319

Protótipo de ponteira acoplada aos aparelhos fotopolimerizadores para colagem de bráquetes e acessórios ortodônticos

Mota Júnior, Sergio Luiz 14 February 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:18:46Z No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:47:10Z (GMT) No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Made available in DSpace on 2016-07-01T18:47:10Z (GMT). No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) Previous issue date: 2012-02-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi o desenvolvimento de uma nova ponteira para ser acoplada aos aparelhos fotopolimerizadores utilizados para colagem de bráquetes e acessórios ortodônticos, e teste da efetividade da mesma em ensaio mecânico in vitro. A ponteira é espelhada na superfície interna e baseia-se em conceitos físicos de refração e reflexão de luz. Apresenta como principal vantagem, a redução do tempo clínico necessário para o procedimento de colagem, reduzindo, dessa forma, a possibilidade de contaminação durante o processo. Através do ensaio de resistência mecânica ao cisalhamento e da determinação do Indice Remanescênte de Adesivo (IRA), testou-se a ponteira em uma amostra composta por 120 corpos de prova, sendo a mesma dividida em 2 grupos. No grupo 1 foi utilizado aparelho fotopolimerizador de fonte de luz halógena e no grupo 2 foi utilizado fonte de LED. Cada grupo foi subdividido. Nos subgrupos H1 e L1 utilizou-se a ponteira convencional dos respectivos instrumentos. Nos subgrupos H2 e L2 a colagem foi feita utilizando-se a ponteira desenvolvida. Os valores dos testes de cisalhamento e IRA para os subgrupos foram comparados entre si. Os resultados mostraram que não houve diferença estatisticamente significante, tanto para os ensaios de resistência ao cisalhamento (p>0,05), quanto para o IRA (p>0,05) entre os subgrupos. Conclui-se que 1 - os testes de ensaios mecânicos, assim como a análise do IRA mostraram que a nova ponteira desenvolvida, cumpriu os requisitos necessários à colagem dos acessórios ortodônticos; 2 – o tempo de colagem foi reduzido pela metade, sendo necessária uma só incidência. / The porpose of the present study was the development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories and test of its efficacy in “in vitro” mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the lesser possibility of contamination during the process. 120 bodies of proof were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used and in group 2 a led lightcuring unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used. In subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p>0,05) and the ARI (p>0,05) between the subgroups. Conclusions are that 1 - The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requisites for bonding orthodontic accessories; 2 - time for bonding was reduced to half, being necessary only one light exposure.
320

Experimentell provning av sprintlyft för att lyfta betongbalkar / Experimental testing of sprint lift for liftingconcrete beams

Schönbeck, Sofie, Johansson, Anna January 2017 (has links)
Sprintlyftet är ett vanligt lyft som används på byggarbetsplatser idag för att montera betongbalkar och det används dessutom när betongbalkarna hanteras i fabriken där de tillverkats. Allt fler prefabricerade byggelement tillverkas och det leder till att lyftens kapacitet behöver säkerställas. I den här studien provades kapaciteten experimentiellt i ett specifikt lyft, sprintlyftet. Det är ett lyft som Abetong använder till sina betongbalkar. Det som under studien kontrollerades var om betongbalkarna idag klarar mer än vad de gjorde vid motsvarande provning för 42 år sedan. En jämförelse mellan provningar som gjordes av Abetong år 1975 och den här studiens provning visar att sprintlyften som används idag klarar av mer last än vad provningarna från 1975 gjorde. Förklaringen till det är främst att kvalitén av betongen har utvecklats under åren. / The sprint lift is a common lift used on construction sites today to mount concrete beams and it is also used when the concrete beams are handled in the factory where they were manufactured. More and more prefabricated building elements are manufactured and this means that the lifts capacity needs to be ensured. In this study, capacity was experimentally tested in a specific lift, the sprint lift. It is a lift that Abetong uses for its concrete beams. What was checked during the study was if the concrete beams today manage more than they did in the corresponding test 42 years ago. A comparison of tests made by Abetong in 1975 and this study's test show that the sprint lift used today is capable of more load than what the 1975 tests did. The explanation for this is primarily that the quality of the concrete has developed over the years.

Page generated in 0.0229 seconds