Spelling suggestions: "subject:"canal radicular"" "subject:"canal adicular""
411 |
Impacto da ativação sônica e ultrassônica do cimento obturador dos canais radiculares na adaptação e resistência de união à dentina / Impact of sonic and ultrasonic activation of root canal sealer in the adaptation and bond strength to dentinPaúl Ernesto Baca Wiesse 07 April 2016 (has links)
O objetivo deste estudo foi avaliar a resistência de união, a penetração e a adaptação à dentina radicular de cimentos obturadores à base de resina epóxica e de silicato de cálcio com e sem ativação sônica e ultrassônica. Raízes de caninos superiores com 16 mm de comprimento foram submetidas a preparo biomecânico com instrumentos rotatórios de níquel titânio sob irrigação constante com NaOCl 2,5% e irrigação final com EDTA 17%. As raízes foram distribuídas em grupos de acordo com os cimentos obturadores: AH Plus e MTA Fillapex. Cada grupo foi subdividido em função da ativação do cimento obturador (n=13): sem ativação; ativação sônica por 30 segundos; ativação ultrassônica por 30 segundos. Em cada subgrupo, a manipulação dos cimentos obturadores foi realizada de acordo com as instruções dos fabricantes para 10 espécimes, para os 3 espécimes restantes, o cimento foi acrescido de Rodamina B 0,1% previamente à manipulação. A obturação foi realizada de acordo com o protocolo de cada subgrupo em relação ao cimento e ativação, utilizando-se a técnica de condensação lateral. Após três vezes os tempos de endurecimento dos cimentos, os espécimes foram seccionados obtendo-se 3 slices de 1,0 mm de espessura de cada terço radicular. Dois slices de cada terço foram submetidos ao teste de push-out e o padrão de falha foi determinado. O terceiro slice de cada terço radicular foi submetido à análise qualitativa da adaptação do cimento à dentina radicular e presença de vazios, por meio de microscopia confocal de varredura a laser. Nos espécimes em que o cimento foi acrescido de Rodamina B 0,1%, avaliou-se a penetração do cimento na dentina radicular por microscopia confocal de varredura a laser com fluorescência. Os dados foram analisados por testes estatísticos paramétricos e não-paramétricos. O cimento AH Plus (2,58±1,21) apresentou maior resistência de união comparado ao MTA Fillapex (1,45±0,71) (p<0,122). A ativação ultrassônica (2,64±1,44) propiciou maior resistência de união comparada aos grupos sem ativação (1,58±0,73) (p<0,0001) e com ativação sônica (1,83±0,85) (p<0,0001), não havendo diferença entre estes (p=0,3303). O terço cervical apresentou maior resistência de união (2,48±1,49) comparado ao médio (2,08±0,94) (p=0,0003) e apical (1,48±0,58) (p<0,001). Para o cimento MTA Fillapex houve predomínio de falhas adesivas mistas em todos os grupos, enquanto que para o cimento AH Plus houve predomínio de falhas adesivas mistas para os grupos sem ativação e ativação ultrassônica e falhas adesivas mistas e adesivas ao material obturador para o grupo de ativação sônica. A ativação ultrassônica promoveu, independente do cimento obturador, maior número, densidade e extensão de tags, com massa obturadora mais homogênea e adaptada às paredes do canal radicular. A ativação sônica, por sua vez, apresentou número, densidade e extensão de tags similares ao grupo sem ativação, no entanto a massa obturadora apresentou desadaptações e formação de bolhas. A ativação ultrassônica impactou na maior resistência de união, penetração, densidade e extensão de tags e melhor adaptação do cimento a dentina radicular, ao contrário da ativação sônica que não aumentou a resistência de união e penetração de tags e proporcionou maior desadaptação e inclusão de vazios na massa obturadora. / The aim of this study was to evaluate the bond strength, penetration and adaptation to the root dentin sealers based on epoxy resin and calcium silicate with and without sonic and ultrasonic activation. Maxillary canine roots with 16 mm length were submitted to biomechanical preparation with nickel titanium rotary files, under constant irrigation with 2.5% NaOCl and final irrigation with 17% EDTA. The roots were divided into groups according to the sealers: AH Plus and MTA Fillapex. Each group was subdivided based on sealer activation (n = 13): no activation; sonic activations (30 seconds); ultrasonic activation (30 seconds). In each subgroup, the sealer manipulation was performed according to the manufacturers instructions for 10 specimens, for the 3 remaining specimens, the Rhodamine B 0.1% was incorpored to the sealer prior to manipulation. The root canal filling was performed according to the protocol of each group relative to the sealer and activation, using the lateral condensation technique. After three times the sealer setting times, the specimens were sectioned and obtained 3 slices of 1.0 mm thickness of each root third. Two slices of each third were submitted to the push-out test and the failure pattern was determined. The third slice of each root third was submitted to qualitative analysis of sealer and root dentin adaptation and the presence of voids, by means of confocal laser scanning microscopy. In specimens in which Rhodamine B 0.1% was added in the sealer was evaluated the sealer penetration in root dentin by confocal laser scanning fluorescence. The data were analyzed using parametric and nonparametric statistical tests. The AH Plus (2.58 ± 1.21) showed higher bond strength compared to MTA Fillapex (1.45 ± 0.71) (p <0.122). The ultrasonic activation (2.64 ± 1.44) provided higher bond strength compared to no activation groups (1.58 ± 0.73) (p <0.0001) and sonic activation (1.83 ± 0.85) (p <0.0001), with no difference between them (p = 0.3303). The cervical third showed higher bond strength (2.48 ± 1.49) compared to the middle (2.08 ± 0.94) (p = 0.0003) and apical thirds (1.48 ± 0.58) (P < 0.001). For the MTA Fillapex there was a predominance of mixed adhesive failures in all groups, whereas for AH Plus there was a predominance of mixed adhesive failures for groups without activation and ultrasonic activation and mixed adhesive failures and adhesives to the filling material for the sonic activation group. Ultrasonic activation promoted, regardless of the sealer, the greater number, density and length tags with more homogenous and adapted root canal filling to the root canal walls. On the other hand, the sonic activation, presented number, density and length of tags similar to the group without activation, however the root canal filling showed mismatches and blistering. Ultrasonic activation impacted the highest bond strength, penetration, density and length tags and better adaptation of the sealer root dentin, unlike the sonic activation that not increased bond strength and penetration tags and provided greater mismatch and the inclusion of voids in the root canal filling.
|
412 |
Evaluation of physicochemical properties of a new epoxy resinbased root canal sealer / Avaliação das propriedades físico-químicas de um novo cimento obturador de canais radiculares à base de resina epóxicaGislene Cristina Vertuan 10 July 2018 (has links)
Introduction: The aim of this study was to evaluate some of the physico-chemical properties of a new root canal sealer. Methodology: The sealers tested were Sealer Plus (MKLife, Porto Alegre, Rio Grande do Sul, Brazil), compared as AH Plus (Dentsply, DeTrey GmbH, Konstanz, Alemanha). For the radiopacity, flow, solubility and fabrication of test specimens relative to setting times the ANSI/ADA No. 57 (2000) and ISO 6876 (2012) specifications were followed. To measure the initial and final setting times the ASTM C266/2008 standard was used. pH was evaluated in the time intervals of 3, 24, 72 and 168 hours). Statistical tests were applied to the results obtained at a level of significance of 5%. Results: The results demonstrated that the Sealer Plus sealer showed a lower radiopacity value than AH Plus sealer (p<0.05), however, this was higher than the minimum value recommended by the specifications; that is 3 mm Al. Relative to flow, the value for Sealer Plus was 19.19 mm and for AH Plus, 19.81 mm (p>0.05). Sealer plus presented initial and final setting times of 138 min. and 210 min., respectively, while the values for AH Plus were 437 min. and 849 min., respectively, (p<0.05). Relative to solubility, Sealer Plus presented 0.21% and AH Plus, 0.27% (p>0.05). None of the sealers showed a significant increase in pH (p>0.05). Conclusion: Sealer Plus sealer presented physico-chemical properties in accordance with ANSI/ADA (2000) No.57 and ISO 6876 (2012) specifications. / Introdução: Este estudo objetivou avaliar algumas propriedades físico-químicas de um novo cimento obturador de canais radiculares. Metodologia: Para os testes de radiopacidade, escoamento, solubilidade e confecção dos corpos de prova para os tempos de presa foram seguidas as especificações nº57 da ANSI/ADA (2000) e ISO 6876 (2012). Para a medição dos tempos de presa, inicial e final, foi empregada a norma ASTM C266/2008. O pH foi avaliado nos períodos de 3, 24, 72 e 168 horas. Sobre os resultados foram aplicados testes estatísticos com nível de significância de 5%. Resultados: Os resultados demonstraram que o cimento Sealer Plus apresentou menor radiopacidade do que o cimento AH Plus (p<0.05), porém, superior ao mínimo recomendado pelas especificações, ou seja, de 3 mm de Al. Com relação ao escoamento, o do Sealer Plus foi 19,19 mm e do AH Plus 19,81 mm (p>0.05). O Sealer Plus apresentou tempos de presa inicial e final de 138 min. e 210 min., respectivamente, enquanto o AH Plus, 437 min. e 849 min., respectivamente, (p<0.05). Em relação à solubilidade, o Sealer Plus apresentou 0,21% e o AH Plus 0,27% (p>0.05). Nenhum dos cimentos apresentou aumento significativo do pH (p>0.05). Conclusão: O cimento Sealer Plus apresentou propriedades físico-químicas de acordo com as especificações nº 57 da ANSI/ADA (2000) e ISO 6876 (2012).
|
413 |
"Análise da citotoxicidade do EDTA e do ácido cítrico aplicados em cultura de macrófagos peritoneais residentes" / Cytotoxicity analysis of EDTA and citric acid applied on murine resident macrophages culture.Amaral, Kali Fatima 08 December 2004 (has links)
O presente estudo avaliou in vitro o efeito citotóxico das soluções de EDTA a 17% e ácido cítrico a 15% sob macrófagos peritoneais residentes, valendo-se do método MTT. Após anestesia e sacrifício de 32 camundongos Swiss machos, procedeu-se a coleta do exsudato celular pela injeção e aspiração de meio de cultura estéril na cavidade abdominal dos animais. Pelo processamento do exsudato peritoneal, obteve-se em média 95% de macrófagos. Alíquotas de 5 x 10 5 células foram plaqueadas em triplicata, de acordo com os grupos experimentais. Diluições de 0,5% de EDTA e ácido cítrico foram adicionadas ao meio de cultura num total de 1 mL. O grupo controle recebeu somente meio de cultura estéril. Verificou-se a citotoxicidade em dois momentos: períodos de curto prazo (0, 6, 12 e 24 horas) e médio prazo (1,3, 5, 7 dias). Ao final dos referidos tempos de observação, as amostras foram tratadas pelo corante MTT, obtendo-se valores de absorbância em leitora ELISA 550 nm. Todo o procedimento experimental foi repetido 2 vezes. No período de curto prazo, a análise de variância apontou diferenças significantes (p< 0,05), sendo Fc=46,07 contra Ft= 3,15, para os grupos avaliados: os Grupos EDTA (0,253 nm) e ácido cítrico (0,260 nm) foram mais citotóxicos que o Grupo controle (0,355 nm). Observações de médio prazo revelaram significância estatística (p< 0,05) entre os grupos, sendo Fc= 171,0 contra Ft= 3,15. Ambas as soluções, EDTA (0,158 nm) e ácido cítrico (0,219 nm), mostraram maior toxicidade em relação ao controle (0,310nm), porém o EDTA apresentou-se mais citotóxico que o ácido cítrico, reduzindo substancialmente a população macrofágica. Como conclusão, as soluções irrigantes testadas exerceram toxicidade aos macrófagos peritoneais em cultura, no entanto, a viabilidade tardia destas células foi menos alterada pelo ácido cítrico / The present study evaluated in vitro cytotoxic effects of 17% EDTA and 15% citric acid in murine resident macrophages using MTT assay. After anesthesia and sacrifice of thirty two Swiss male mice, it had processed the peritoneal cellular exudates by fresh culture medium injection and aspiration in peritoneal animals cavities. The peritoneal exudates were composed approximately by 95% of macrophages. 5x 10 5 cells were plated in triplicate, according experimental groups. Each 0.5% dilutions of EDTA and citric acid were applied in medium culture, resulting 1 mL volume. Fresh medium served as control. The cytotoxicity was evaluated in two moments: short term (0, 6, 12, 24 hours) and long term (1, 3, 5, 7 days). After tested periods, the samples were treated by MTT ink assay and absorbance was determined using ELISA microplate reader at 550 nm. All these procedures were repeated twice. To short term period, ANOVA showed significant differences (p< 0.05) among groups (Fc= 46.07 x Ft= 3.15). EDTA (0.253 nm) and citric acid (0.260 nm) groups exhibited more cytotoxicity than control group. Long term observations exhibited statistical differences (p< 0.05), that Fc= 171.0 x Ft= 3.15. EDTA (0.158 nm) and citric acid (0.219 nm) solutions were cytotoxic when compared to control group, thus EDTA reduced greater macrophages viability than citric acid. Based on our results it seems that final irrigants tested presented toxic effects to murine macrophages culture, but in long term evaluation citric acid was considered less irritant.
|
414 |
CONDICIONAMENTO DA SUPERFÍCIE DE PINOS DE FIBRA DE VIDRO: INFLUÊNCIA NA RESISTÊNCIA ADESIVA APÓS CICLAGEM MECÂNICA E NA RESISTÊNCIA À FLEXÃO DOS PINOS / Post surface conditioning: effect on bond strength to composites after aging and on flexural strength of fiber posts.Amaral, Marina 06 November 2010 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Aim: To evaluate the bond strength between glass fiber post and intrarradicular dentin or core composite resin after several post surface treatments, and the effect of surface treatments on posts flexural strength. Material and methods: The following post surface treatments were evaluated: G1- no conditioning; G2- cleaning with alcohol (AL); G3- AL + silane application (SIL); G4- Al2O3 + SIL; G5- H2O2 + SIL; G6- HF + SIL; G7- H3PO4 + SIL. Tem double-tapered fiber posts from each evaluated surface treatment were cemented into bovine teeth previously embedded into acrylic resin. After, a standard composite resin cylindrical core was build up. Samples were submitted to mechanical cycling (106 cycles, 4 Hz, 37ºC) and sectioned into 2 mm slices. For root portion the bond strength was measured through push-out test, while core slices were machined into hour-glasses and submitted to microtensile bond strength test. The three point bending test was applied to cylindrical posts from G1, G4, G5, G6 and G7, to flexural strength evaluation. Moreover, two posts from these groups were conditioned for scanning electron microscopy (SEM). One-way analysis of variance followed by Tukey s test were applied to each evaluation (α=0,05). Results: the post surface conditioning had no effect on post retention into root canal (p=0,876), however the microtensile bond strength between post and composite resin was significantly affected (p<0,001), where G3 presented the highest values of bond strength. The flexural strength was also influenced by post surface conditioning, where sandblasting with Al2O3 125 μm significantly decreased the posts strength. The analysis through SEM revealed different patterns of surface s modification after conditioning. Conclusions: (1) post retention into root dentin was not affected by post surface conditioning, bust silane application promotes higher microtensile bond strength between post and composite resin; (2) sandblasting posts surface with Al2O3 125 μm decreased posts flexural strength; and (3) different patterns of surface conditioning were observed under SEM. / Objetivo: O objetivo deste estudo foi avaliar a resistência adesiva entre pino de fibra de vidro e dentina intrarradicular ou resina composta do núcleo após diferentes tratamentos de superfície dos pinos, e a influência do tratamento de superfície da resistência à flexão dos pinos. Materiais e Métodos: Os seguintes métodos para tratamento da superfície dos pinos foram avaliados: G1- sem tratamento; G2- limpeza com álcool; G3- limpeza com álcool + aplicação de silano (SIL); G4- Al2O3 125 μm + SIL; G5- H2O2 + SIL; G6- HF + SIL; G7- H3PO4 + SIL. Dez pinos de fibra de vidro duplo-cônicos condicionados com cada um dos tratamentos listados acima (n=10) foram cimentados em raízes bovinas, embutidas perpendicularmente em resina acrílica. Após, um núcleo cilíndrico padronizado foi reconstruído em resina composta. Os corpos de prova foram submetidos a 106 ciclos mecânicos (100 N, 4 Hz, 37°C, 45°) antes de serem seccionados em fatias de 2 mm de espessura. Para a porção radicular, a resistência adesiva foi medida através do teste de extrusão push-out, enquanto que para a resistência adesiva da porção coronária, foi utilizado o teste de microtração com espécimes em forma de ampulheta. Para avaliação da resistência à flexão, pinos com os tratamentos correspondentes aos grupos G1, G4, G5, G6 e G7 (n=5) foram submetidos ao teste de flexão de três pontos. Além disso, dois pinos com tratamentos de superfície destes grupos foram cobertos com ouro e submetidos à análise em MEV. Análise de variância 1-fator foi aplicada para cada uma das avaliações, seguida do teste de Tukey para contraste de médias (α=0,05). Resultados: Para retenção no canal radicular, a modificação da superfície dos pinos não foi relevante (p=0,876). Porém, a adesão entre pino de fibra e resina composta foi estatisticamente afetada pelos tratamentos de superfície (p<0,001), sendo do G3 os maiores valores de resistência adesiva à microtração. O fator de estudo também afetou a resistência à flexão: Al2O3 125μm apresentou diminuição significativa na resistência dos pinos. Sob análise em MEV, diferentes padrões de superfície foram observados após condicionamentos. Conclusões: (1) a retenção do pino no canal radicular não foi afetada pelos tratamentos sugeridos, porém a aplicação de silano na superfície do pino parece aumentar a retenção do núcleo de resina composta; (2) o jateamento da superfície dos pinos com Al2O3 125 μm pode ser danoso para as propriedades de flexão dos pinos; e (3) diferentes padrões de morfologia de superfície foram observados sob MEV.
|
415 |
Avaliação clínica do uso de pinos de fibra de carbono na restauração de dentes tratados endodonticamente : um estudo retrospectivoCoppo, Priscilla Pessin 16 April 2010 (has links)
Made available in DSpace on 2016-12-23T13:54:32Z (GMT). No. of bitstreams: 1
Priscilla Pessin Coppo.pdf: 1791694 bytes, checksum: 6f106783f17f1ac295e2e147181651cf (MD5)
Previous issue date: 2010-04-16 / Os estudos clínicos de dentes desvitalizados e restaurados com pinos mostram resultados semelhantes no que diz respeito ao percentual de falhas ou insucessos, apesar de tantas variações técnicas, metodológicas e operatórias entre eles. Os insucessos são maiores quando se tratam de elementos dentais coronariamente destruídos ou comprometidos periapicalmente. Com o objetivo de identificar o efeito das variações clínicas que influenciam na longevidade do tratamento e a prevalência de descimentação de pinos, cárie marginal, fraturas radiculares e de lesões periapicais, foi realizada uma análise retrospectiva do desempenho clínico de dentes restaurados com pino de fibra de carbono. Foram avaliados 139 dentes em 75 pacientes, três anos após a data de cimentação dos pinos. Os dentes foram submetidos a tratamentos endodônticos, incluindo preparos dos condutos para pino, e tratamentos restauradores, realizados pelo mesmo endodontista e protesista, respectivamente, segundo protocolos padronizados. Através de exame clínico, radiográfico, fotográfico, laudos endodônticos e informações obtidas de prontuários, os dentes foram classificados de acordo com: grupos dentais, modalidade de tratamento endodôntico recebida, intervalo decorrido entre a última sessão endodôntica e a cimentação do pino, morfologia do pino, quantidade de remanescente dentinário coronário após preparo protético e sistema da coroa protética utilizado. Não foram constatadas descimentações de pinos, fraturas
radiculares, ou cáries, e a classificação foi favorável para 99,3% (138 dentes) dos tratamentos endodônticos realizados. De acordo com os parâmetros analisados, os resultados desse estudo revelaram que as variações clínicas identificadas,
consideradas desfavoráveis, não foram fatores determinantes para o insucesso, partindo-se do conjunto de procedimentos e materiais utilizados para o tratamento dos dentes desses pacientes / Clinical studies of devitalized teeth restored with posts show similar outcomes with regard to the percentage of faults or failures, despite many technical variations, methodological and operative between them. The failures are greater when dealing with teeth coronally destroyed or periapically compromised. The aim of this study was identify the effect of clinical variants that influence the longevity of treatment and
prevalence of dislodgment of post, marginal caries, root fracture and periapical lesions was performed a retrospective analysis of clinical performance of teeth restored with carbon fiber post. 139 teeth were evaluated in 75 patients, three years after the date of cementing the posts. The teeth were root canal treatments, including preparations of the conduits to posts, and restorative treatments, performed by the same endodontist and prosthetics, respectively, according to standardized protocols. Through clinical, radiographic, photographic, endodontic reports and information obtained from medical records, the teeth were classified according to: tooth groups, type of endodontic treatment received, time span between the last endodontic session and bonded post, morphology of the post, amount of remaining dentin after
crown preparation and prosthetic crown system used. There were no dislodgment of post, root fractures, or caries, and the rank was favorably for 99.3% (138 teeth) of endodontic treatment. According to these parameters, the outcomes of this study revealed that the clinical variations identified, that are considered unfavourable, were not determining for the failure, starting from the set of procedures and materials used
for dental treatment of these patients
|
416 |
Análise microscópica de capeamento pulpar direto com diferentes materiais em dentes humanos / Microscope analyze of direct dental pulp capping with differents materials in human teethPatricia de Oliveira Penina 06 November 2007 (has links)
O capeamento pulpar direto busca preservar a vitalidade pulpar. Este trabalho apresenta a resposta tecidual de polpas humanas ao capeamento pulpar direto com o Agregado de Trióxido Mineral (MTA) comparado com o hidróxido de cálcio. Foram utilizados 20 pré-molares de dez pacientes com extração indicada para tratamento ortodôntico. Todos os dentes apresentavam vitalidade pulpar e neles foram feitos capeamentos pulpares diretos com MTA ou com o hidróxido de cálcio. Os dentes foram extraídos num período de 14 dias ou 45 dias, estabelecendo os seguintes grupos experimentais: Ca(OH) 14 dias; Ca(OH) 45 dias; MTA 14 dias e MTA 45 dias. Estes dentes foram analisados microscopicamente por dois examinadores treinados. Os dados obtidos foram tabulados, utilizando-se o teste Kappa para observar o grau de concordância entre os examinadores. Para avaliação comparativa entre as respostas citotóxicas dos materiais testados foi aplicado o teste não paramétrico Kruskal-Wallis e o teste de Dunn para comparações individuais e identificação da significância dos achados. Na análise dos resultados não houve diferença estatisticamente significante entre os grupos nos períodos experimentais de 14 e 45 dias, e nem na resposta inflamatória pulpar frente ao hidróxido de cálcio quando comparado ao MTA. Quanto à espessura e à organização da barreira dentinária reparatória com o hidróxido de cálcio, quando comparado com o MTA também não apresenta diferença estatisticamente significante. Conclui-se que o MTA satisfaz os requisitos de um material capeador pulpar em dentes de humanos, apresentando propriedades físicas e biológicas que o indicam para este tratamento. / The direct dental pulp capping aims to preserve the pulp vitality. This work shows the tissue response from human pulps to that procedure with the Mineral Trioxide Agregate (MTA) compared to calcium hydroxide - Ca(OH)2. Twenty premolars from 10 patients with extraction indicated to orthodontic treatment were used. All teeth showed pulp vitality and were treated with direct dental pulp capping with MTA or with calcium hydroxide. The teeth have been extracted within 14 or 45 days, stablishing the following experimental groups: Ca(OH)2 14 days; Ca(OH)2 45 days; MTA 14 days; and MTA 45 days. These teeth were analyzed under microscopy by two observers trained. The data obtained were put in table using the Kappa test to note the agreement degree between the observers. For the comparative assessment between the citotoxic response from material tested has been applied the non-paired Kruskal-Wallis test, and the Dunns test for individual comparisons and identifying the significance of findings. In the analysis of results there had no statistically significant difference between the groups in experimental periods of 14 days and 45 days, not even in the pulp inflammatory response to calcium hydroxide when compared to MTA. The thickness and arrangement of the healing dentin barrier faced with calcium hydroxide, when compared to MTA, also showed no statistically significant difference. It may be concluded that the MTA fulfils the requirements of pulp capping material in human teeth showing biological and physical properties that indicate it for this treatment.
|
417 |
Biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) / Biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta)Felipe Gonçalves Belladonna 04 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo desse trabalho foi avaliar a biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) em tecido subcutâneo de camundongos. A guta-percha convencional foi utilizada como referência para comparação. Para isso, foram utilizados 30 camundongos, os quais foram distribuídos aleatoriamente em dois grupos (Bio-Gutta e guta-percha convencional). Os materiais avaliados foram implantados na região dorsal dos camundongos. Após 7, 21 e 63 dias, os animais foram sacrificados e 5 amostras por grupo por tempo experimental foram obtidas. As amostras histológicas foram seccionadas em 5 m de espessura e coradas convencionalmente com hematoxilina e eosina. Um escore de I-IV foi utilizado para graduar a reação inflamatória. O teste U de Mann-Whitney com correção de Bonferroni foi utilizado para análise estatística (p < 0,05). Os resultados mostraram que, após 7 dias, a Bio-Gutta induziu uma reação tecidual de leve a moderada (II) e a guta-percha convencional apresentou uma resposta inflamatória de moderada a intensa (III). Após 21 dias, a Bio-Gutta induziu uma leve reação tecidual (I), enquanto que a guta-percha convencional ainda apresentava uma resposta inflamatória moderada (III). Uma reação tecidual de leve a ausente (I) foi observada na Bio-Gutta após 63 dias, ao passo que na guta-percha convencional observou-se uma resposta inflamatória de leve a moderada (II). Houve diferença significativa na mediana do grau de inflamação entre os grupos em cada tempo experimental (p = 0,005, aos 7 dias; p = 0,011, aos 21 dias; e p = 0,003, aos 63 dias). Concluiu-se então que a Bio-Gutta foi mais biocompatível que a guta-percha convencional em tecido subcutâneo de camundongos apresentando uma boa resposta tecidual. / The purpose of this study was to evaluate the biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta) in connective tissue of mice. Conventional gutta-percha was used as reference for comparison. Thirty mice were used in this study and they were randomly assigned into two groups (Bio-Gutta and conventional gutta-percha). The tested materials were implanted in the dorsal region of mice. After 7, 21 and 63 days, animals were sacrificed and 5 samples per group per time-point were obtained. Histologic samples were sectioned in 5 m thickness and stained with conventional hematoxylin and eosin. A grade from I-IV was used to graduate the inflammatory reaction. Bonferroni-corrected Mann-Whitney U test was used for statistical analysis (p < 0,05). The results showed that after 7 days Bio-Gutta induced a slight to moderate tissue reaction (II) and conventional gutta-percha presented a moderate to intense inflammatory response (III). After 21 days, Bio-Gutta presented a slight tissue reaction (I), while conventional gutta-percha still showed a moderate inflammatory response (III). A slight to absent tissue reaction (I) was observed in Bio-Gutta after 63 days, whereas conventional gutta-percha showed a slight to moderate inflammatory response (II). There was a significant difference in the median degree of inflammation between the groups at each time-point (p = 0,005, at 7 days; p = 0,011, at 21 days; and p = 0,003, at 63 days). It was concluded that Bio-Gutta was more biocompatible than conventional gutta-percha in subcutaneous tissue of mice showing a good tissue response.
|
418 |
Avaliação microtomográfica de canais mesiais de molares inferiores preparados com sistemas rotatórios e reciprocantes / Computed microtomography analysis of mesial canals of mandibular molars prepared with rotary and reciprocating systemsMarília Fagury Videira Marceliano Alves 12 September 2013 (has links)
O objetivo do presente trabalho foi avaliar, em microtomografia computadorizada (CT), o preparo de canais de molares inferiores com diferentes sistemas acionados a motor. Foram selecionadas 58 raízes mesiais patentes, de diâmetro anatômico correspondente a #10. Para a avaliação em TC, um anel de aço inoxidável foi confeccionado nos moldes do suporte para amostra do microtomógrafo, para que servisse de fôrma para a inclusão das raízes em resina Duralay, a fim de padronizar a posição do espécime no escaneamento inicial e final. Os canais foram preparados com os sistemas Reciproc R25 (n=16); WaveOne Primary File (n=16); Twisted File (n=14), e HyFlex (n=12). Após serem escaneados, foram reconstruídos tridimensionalmente e avaliados quantitativamente quanto à variação de volume (mm3), área de superfície (mm2) e structure model index (SMI). Foi, ainda, realizada a avaliação qualitativa das seções transversais por terço e por quadrante (MV, ML, DV, DL), sendo avaliado o toque de paredes. Os dados paramétricos foram analisados estatisticamente pelos testes ANOVA e t para amostras pareadas (α=5%). Não foi observada diferença estatística nos parâmetros quantitativos avaliados para Reciproc (142,77 76,75; 42,22 19,22; e 14,68 17,69, respectivamente); WaveOne (105,09 64,82; 29,54 19,21; 14,81 9,10, respectivamente); Twisted File (111,83 43,09; 33,31 18,40; 9,16 6,57, respectivamente), e HyFlex (151,74 149,37; 43,08 41,44; 10,80 8,52, respectivamente) (p=0,423). Dentro de cada grupo, foi observada diferença significante entre os resultados pré e pós-operatórios. O teste não paramétrico de Kruskal Wallis foi aplicado para a avaliação relativa ao toque de paredes. Foi observado que o sistema HyFlex apresentou a maior porcentagem de toques (82,3 13,1), seguido por Reciproc (81,3 16,9), Twisted File (78,3 14,4) e, por fim, WaveOne (76,9 21,7) (p>0,05). Em relação aos terços não foi observada diferença significativa (p=0,424). Os resultados da avaliação dos quadrantes intergrupo não demonstraram diferenças, porém indicaram tendência do preparo em direção à parede distal no terço cervical. Ao final, pôde-se concluir que os sistemas testados se equivalem quanto ao preparo de canais mesiais de molares inferiores; porém, nenhuma das técnicas foi capaz de tocar completamente em todas as paredes do canal radicular. / The aim of this work was to analyze, in X-ray computed microtomography (CT), the root canal preparation of mandibular molars with different engine driven systems. 58 mesial roots were selected, of anatomic diameter corresponding to #10. For the analysis in TC, a stainless steel ring was manufactured in the same shape as the brace for CT sampling, in order to serve as a mold to insert the roots in Duralay resin, so as to standardize the position of the specimen in the initial and final scanning. The canals were prepared with the Reciproc R25 (n=16), WaveOne Primary File (n=16), Twisted File (n=14) and HyFlex (n=12) systems. After being scanned, they were three-dimensionally reconstructed and quantitatively evaluated as regards the variation of volume (mm3), surface area (mm2) and structure model index (SMI). In addition, the qualitative evaluation of the cross sections by third and by quadrant (MV, ML, DV, DL) was carried out, along with the wall touching evaluation. The parametric data were statistically analyzed by ANOVA and t-tests for paired samples (α=5%). No statistical difference was observed in the qualitative parameters evaluated for Reciproc (142.77 76.75; 42.22 19.22; and 14.68 17.69; respectively), WaveOne (105.09 64.82; 29.54 19.21; 14.81 9.10; respectively), Twisted File (111.83 43.09; 33.31 18.40; 9.16 6.57; respectively) and HyFlex (151.74 149.37; 43.08 41.44; 10.80 8.52) (p=0,423). Significant difference was observed within each group between the pre- and post-results. The Kruskal-Wallis non-parametric test was applied for the evaluation as regards root canal wall touching. At the end, we observed that the HyFlex system presented the highest touching rate (82.3 13.1), followed by the Reciproc (81.3 16.9), Twisted File (78.3 14.4) and, finally, WaveOne (76.9 21.7) systems (p>0.05). As for the thirds, was not observed any significant difference (p=0.424). The results of the evaluation in the intergroup quadrants did not show any difference; however, they showed that there was a preparation trend towards the distal wall in the cervical third. At the end, it can conclude that the systems tested are equivalent as regards the preparation of mesial canals of mandibular molars, but none of the techniques was capable of fully touching all root canal walls.
|
419 |
Influência da espessura do filme de cimento na resistência adesiva de pinos de fibra de vidro cimentados em condutos radiculares de dentes humanos / Influence of the cement film thickness on the push out bond strength of glass fiber posts cemented in human root canalsNatália Araújo Silva Prado 08 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo visa avaliar a influência da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro em diferentes regiões do conduto radicular (cervical, médio e apical), cimentados com cimento resinoso autoadesivo, com e sem a adição de Rodamina B, por meio do teste de push-out. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Após sete dias, os condutos foram desobstruídos e aleatoriamente divididos em 4 grupos (n=10), de acordo com as brocas do sistema de pinos de fibra WhitePost DC (FGM) usadas: (G1) broca #2; (G2) broca #3; (G3) broca #4; (G4) broca #2. O preparo foi realizado a uma profundidade de 10 mm. A cimentação foi realizada com o cimento resinoso autoadesivo RelyX U100 (3M ESPE), e apenas nos grupos G1, G2 e G3 uma pequena quantidade de Rodamina B em pó foi usada como corante no cimento. Após uma semana, cada raiz foi seccionada em máquina de corte, obtendo-se 6 fatias de 1 0,1 mm de espessura. Antes do ensaio de push-out, imagens digitais foram obtidas, por meio de um estereomicroscópio, de ambas as faces de cada fatia, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram obtidas para determinação do modo de falha. Para determinar a espessura de cimento, foi desenvolvida uma rotina (macro) no software KS 400. Os dados foram estatisticamente analisados com análise de variância (ANOVA) 2 fatores (influência do diâmetro da broca e influência dos terços) e Kruskal-Wallis (influência da espessura do filme de cimento). Comparações múltiplas foram realizadas com o teste Duncan. Todos os testes foram aplicados com α=0,05. Houve diferenças significantes entre os grupos em relação ao diâmetro da broca (p<0,0001), sendo G2 (14,62 5,15 MPa) > G1 (10,04 5,13 MPa) > G3 (7,68 6,14 MPa). O terço do conduto exerceu influência significativa sobre a resistência adesiva (p<0,0001), sendo os maiores valores obtidos no terço apical. As espessuras do filme de cimento foram estatisticamente diferentes nos grupos. Os maiores valores de espessura de cimento foram obtidos no G3 (248,78 μm), seguido de G2 (185,91 μm) e G1 (110,16 μm), sendo o último estatisticamente semelhante ao G4 (119,99 μm). Os resultados de G1(10,04 5,13 MPa) e G4 (8,89 + 5,18 MPa) foram estatisticamente semelhantes, indicando que a presença da Rodamina B não influencia significativamente na resistência de união. O tipo de falha predominante no G1 foi mista, no G2, adesiva entre pino e cimento, e no G3 e G4, adesiva entre cimento e dentina. O diâmetro da broca influenciou significativamente nos resultados de resistência de união ao teste de push-out. O ligeiro aumento na espessura do filme de cimento promoveu um aumento nos valores de resistência, quando comparado com filmes de cimento muito finos ou muito espessos. / The present study has the purpose of evaluating the influence of the cement film thickness on the bond strength of glass fiber posts in different portions of the root canal (cervical, medium, and apical), cemented with self-adhesive resin cement, with and without the addition of Rhodamine B, by means of the push-out test. Forty roots were included in epoxy resin, underwent endodontic treatment, and were filled with gutta-percha and endodontic cement without eugenol. After seven days, the canals were de-obstructed and randomly divided into four groups (n=10), according to the WhitePost DC (FGM) fiber glass post systems burs: (G1) bur #2; (G2) bur # 3; (G3) bur #4; (G4) bur #2. The preparation was made at a 10 mm depth. The posts were cemented with RelyX U100 (3M ESPE) self-adhesive resin cement, and only in groups G1, G2, and G3 a small amount of powdered Rhodamine B was used as a stain in the cement. After one week, each root was sliced in a cutting machine, resulting in six slices 1 0,1 mm thick. Before the push-out test, a stereomicroscope was used to obtain digital images of both sides of each slice, in order to determine the radius of the posts, as well as the thickness of the cement film. After the mechanical test, new images were obtained, to determine the failure mode. In order to determine the cement thickness, a macro routine was developed in the software KS 400. The data were analyzed statistically through two-way ANOVA (influence of the bur diameter and influence of the thirds), and Kruskal-Wallis (influence of the cement film thickness). Duncan test was used for multiple comparisons. All tests were run with α=0,05. There were significant differences between the groups regarding the bur diameter (p<0,0001), with G2 (14,62 5,15 MPa) > G1 (10,04 5,13 MPa) > G3 (7,68 6,14 MPa). The canal portion had significant influence on the bond strength, and the highest values were obtained at the apical third (p = 0,0001). The cement film thicknesses were statistically different in all groups. The highest cement thickness values were obtained in G3 (248,78 μm), followed by G2 (185,91 μm), and G1 (110,16 μm), the latter being statistically similar to G4 (119,99 μm). G1 (10,04 5,13 MPa) and G4 (8,89 + 5,18 MPa) showed statistically similar results, which indicates that the presence of Rhodamine B did not significantly influence the bond strength. The predominant type of failure for G1 was mixed, for G2 was adhesion between post and cement, and for G3 and G4 was adhesion between cement and dentin. The bur diameter significantly influenced the results for shear bond strength for the push-out test, as well as the cement film thickness. The slight increase in the cement thickness allowed an increase in the values of shear bond strength in comparison with very thin or very thick cement films.
|
420 |
Avaliação da citotoxicidade de cimentos endodônticos em relação aos reativos intermediários do oxigênio e nitrogênio em culturas de macrófagos peritoneais de camundongosSilva, Paulo Tadeu da [UNESP] 30 August 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-08-30Bitstream added on 2014-06-13T18:42:17Z : No. of bitstreams: 1
silva_pt_dr_arafo.pdf: 428042 bytes, checksum: fe2b6b39c1693d5ed4af444bc6e9be75 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Analisou-se a citotoxicidade dos seguintes cimentos: Endofill, Sealapex e Polifil, quanto à liberação de óxido nítrico (NO) e peróxido de hidrogênio (H2O2) em culturas de macrófagos peritoneais de camundongos e também utilizamos um método de análise colorimétrica usando M.T.T. Concluiu-se que as considerações presentes após os resultados, discussão e constatação os cimentos que apresentaram o menor nível de citotoxicidade foi o Endofill, seguido da equivalência de liberação de Polifil e Sealapex, embora todos foram menos citotóxicos que o Grupo Controle Zimosan-A para H2O2 e o LPS para o NO. / It was analyzed the citotoxicity of the following cements Endofill, Sealapex, and Poliol regarding the nitric oxide (NO) release and the hydrogen peroxide (H2O2) in the peritoneais macrophages medium of mice in different concentrations and we have also analyzed a colorimetric method using the M.T.T. It was concluded from the considerations which were present in the results, discussion, and verification that the cement which presented the lowest citotoxicity level was the Sealapex followed by the Polifil and the Endofill, although all of them were less citotoxic than the Zimosan-A control group for H2O2 and the LPS for the NO.
|
Page generated in 0.0644 seconds