• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 232
  • 17
  • 12
  • 12
  • 12
  • 12
  • 11
  • 7
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 267
  • 267
  • 220
  • 218
  • 79
  • 76
  • 74
  • 74
  • 64
  • 60
  • 57
  • 54
  • 34
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Avaliação de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias / Evaluation of experimental titanium alloys for prosthodontic frameworks

Adriana Cláudia Lapria Faria Queiroz 29 May 2009 (has links)
A utilização do titânio em odontologia tem aumentado devido suas propriedades mecânicas, biocompatibilidade, resistência à corrosão e baixo peso específico. Entretanto, o uso do titânio em próteses ainda não é rotineiro em virtude de dificuldades no processo de fundição. Uma das maneiras de superar estas dificuldades seria através do desenvolvimento de novas ligas cujo ponto de fusão fosse inferior ao do Ti cp. O objetivo deste estudo foi avaliar as propriedades mecânicas, biológicas e microestrutura de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias, após fundição odontológica, comparando-as ao Ti cp. As ligas experimentais avaliadas foram Ti-5Zr(%p), Ti-5Ta(%p) e Ti-5Ta-5Zr(%p). Os corpos-de-prova foram fundidos por arco voltaico em atmosfera de argônio e injeção por vácuo-pressão. Para avaliação das propriedades mecânicas, corpos-deprova em forma de halteres foram submetidos a ensaios de tração, barras foram submetidas a ensaios de flexão para avaliação do módulo de elasticidade, e hemi-esferas e discos foram submetidos ao teste de desgaste de dois corpos, sendo o perfil das amostras avaliado antes e após o teste para cálculo da perda de altura vertical. Discos foram utilizados para avaliação da microdureza e para caracterização microestrutural. Para avaliação das propriedades biológicas, células SCC9 foram cultivadas em meio de cultura D-MEM/HF12 suplementado sobre discos e poços sem discos foram usados como controle. Após períodos de 1, 4, 7, 10 e 14 dias, foi avaliada a proliferação celular pelo método histoquímico MTT. Aos 7 dias foi avaliada a viabilidade celular após marcação com azul de Trypan e contagem em hemocitômetro. A morfologia celular foi avaliada às 2, 12 e 24 horas através da visualização, em microscópio de fluorescência por epiluminação, do citoesqueleto de actina e dos núcleos, usando, respectivamente, faloidina e DAPI. Os resultados foram submetidos a testes estatísticos e a liga Ti-5Ta apresentou resistência à tração menor que as demais e módulo de elasticidade significativamente menor do que o Ti cp, embora não diferente das demais ligas experimentais. Com relação à resistência à abrasão, as ligas experimentais apresentaram desgaste significativamente menor do que o Ti cp e a liga Ti-5Zr apresentou microdureza significativamente maior do que os demais materiais. Não houve diferença na proliferação e na viabilidade celular entre os materiais. A avaliação da morfologia celular mostrou diferença na proporção de células nos diferentes estágios de desenvolvimento nos períodos de 2 e 12 horas, mas não em 24 horas. O Ti cp apresentou microestrutura do tipo feather-like com fase α, enquanto Ti-5Zr apresentou estrutura do tipo Widmanstätten com fase α e α´. As ligas Ti- 5Ta e Ti-5Ta-5Zr apresentaram as fases α, α´, α´´ e β, com arranjos lamelar e acicular, respectivamente. Os resultados deste estudo sugerem que as ligas estudadas apresentam potencial para aplicação em próteses dentárias, uma vez que suas propriedades biológicas foram semelhantes às do Ti cp, comprovado por proliferação, viabilidade e morfologia celular; e suas propriedades mecânicas, como resistência à abrasão, microdureza e resistência à tração foram satisfatórias, ainda que o módulo de elasticidade possa e deva ser melhorado. / The use of titanium in dentistry have increased due to its mechanical properties, biocompatibility, corrosion resistance and density. However, titanium has not been routinely used because of the difficulties related to casting technique. One of the options to solve these difficulties would be to develop new titanium alloys whose melting point was lower than cp Ti. So, the aim of this study was to evaluate the mechanical and biological properties and microstructure of experimental titanium alloys for prosthesis frameworks, after dental casting, comparing to cp Ti. The experimental alloys evaluated were Ti-5Zr(%w), Ti-5Ta(%w) and Ti-5Ta-5Zr(%w). The samples were cast by voltaic arc in argon atmosphere and vaccum/pressure injection. To evaluate the mechanical properties, dumbbell-shaped samples were submitted to tensile test, slab-shaped were submitted to flexure for modulus of elasticity evaluation, and stylus tips and disks were submitted to two-body wear test, evaluating the profile of the samples before and after the test to calculate vertical height loss. Disks were used for microhardness evaluation and microstructural observation. For the biological properties evaluation, SCC9 cells were cultured in D-MEM/HF12 supplemented on the disks and wells without disks were used as control. After 1, 4, 7, 10 and 14-day period, cell proliferation was measured by MTT method. After 7 days, cell viability was evaluated after Trypan blue marking and counting in a hemacytometer. Cell morphology was evaluated in 2, 12 and 24-hour periods examining, in fluorescence microscope under epifluorescence, actin cytoskeleton and cell nuclei, using, respectively, phalloidin and DAPI. The results were submitted to statistical analysis and Ti-5Ta alloy presented ultimate tensile strength lower than the others and modulus of elasticity statistically lower than cp Ti, but no different to the other experimental alloys. In relation to wear resistance, the experimental alloys presented wear significantly lower than cp Ti and the Ti-5Zr alloy presented microhardness greater than other materials. Cell morphology evaluation showed difference in the proportion of cells in the different stages in 2 and 12-hour periods, but not in 24. The cp Ti presented feather-like structure with α phase while Ti-5Zr presented a Widmanstätten structure with α and α´ phases. The Ti-5Ta and Ti-5Ta-5Zr alloys presented α, α´, α´´ and β phases with lamellar and acicular structures, respectively. The results of this study suggest that the studied alloys could be applied in dental prosthesis, once their biological properties were similar to cp Ti in cell proliferation, viability and morphology; and their mechanical properties, like wear resistance, microhardness and ultimate tensile strength were ideal, although the modulus of elasticity can and should be improved.
212

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Wendel Teixeira 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.
213

Eficácia da escovação associada à irrigação oral na manutenção dos tecidos peri-implantares e overdentures estudo clínico randomizado / Effectiveness of brushing associated with oral irrigation in maintenance of peri-implant tissues and overdentures randomized clinical trial

Marcela Moreira Salles 27 January 2017 (has links)
A manutenção das próteses implantossuportadas e da saúde dos tecidos peri-implantares está diretamente relacionada ao sucesso do tratamento reabilitador. O objetivo deste trabalho foi avaliar, por meio de estudo clínico randomizado, a eficácia de um método experimental (escovação associada à irrigação oral), na manutenção dos tecidos peri-implantares e overdentures. Foram analisadas capacidade de remoção de biofilme e manutenção da saúde dos tecidos orais, ação antimicrobiana e satisfação do paciente. Foram selecionados 38 pacientes usuários de prótese total superior convencional e overdenture inferior, retida por implantes ou mini-implantes e sistema de encaixe tipo o\'ring. Os pacientes utilizaram os seguintes métodos: ES (Controle): método mecânico da escovação - escova específica para próteses totais, escova dental de cerdas macias e dentifrício e WP (Experimental): associação da escovação com a irrigação oral (Waterpik). Os pacientes foram orientados a higienizar suas próteses e tecidos peri-implantares, por meio do método da escovação, por 2 minutos, 3 vezes ao dia, sendo que no método experimental, os pacientes utilizaram a irrigação oral, uma vez ao dia, após a escovação, direcionando o jato de água à margem gengival e região dos componentes protéticos das overdentures. Todos os pacientes utilizaram os dois métodos de higiene, em uma sequência aleatória, por um período de 14 dias, com um período intercalado de 7 dias de wash out. As avaliações foram realizadas antes (baseline) e após a utilização de cada método. A capacidade de remoção de biofilme e a manutenção da saúde oral dos tecidos foram avaliadas por meio do Índice de Placa Modificado (IP), Índice Gengival (IG), Profundidade de Sondagem (PS) e Índice de Sangramento à Sondagem (SS). Para a análise da ação antimicrobiana, o biofilme subgengival foi coletado por meio de cones de papel e biofilme presente nos componentes das overdentures por meio de microbrush, e as amostras coletadas foram processadas pela técnica de hibridização DNA Checkerboard (39 espécies microbianas avaliadas). Os pacientes responderam a um questionário específico por meio de Escala Visual Analógica (EVA) de 100,0 mm, após o uso de cada método. Os dados relacionados aos parâmetros clínicos e à ação antimicrobiana foram analisados por meio do teste de Friedman (&alpha;=0,05), seguido de comparações realizadas por meio do teste de Wilcoxon; as comparações entre implantes convencionais e mini-implantes foram realizadas por meio do teste de Mann-Whitney (&alpha;=0,05). A análise das respostas ao questionário de satisfação foi realizada por meio do teste de Wilcoxon (&alpha;=0,05). Os resultados mostraram que, quanto aos parâmetros clínicos, houve diferença estatisticamente significante entre os valores obtidos no baseline e os valores após os métodos avaliados (p<0,001); entre os métodos ES e WP, não houve diferença significante (IP, IG e PS: p=1,000; SS: p=0,828); houve diferença estatisticamente significante entre os diferentes tipos de implantes apenas do IP após ES (p<0,05). Houve diferença estatisticamente significante entre os métodos (p<0,05), quando comparados os valores da quantidade total de células microbianas presentes no biofilme subgengival, sendo WP mais efetivo que ES (p<0,05), porém não houve diferença entre baseline e WP (p>0,05); considerando os micro-organismos avaliados, WP promoveu redução mais efetiva que ES apenas da espécie C. rectus (p=0,001). A quantidade total de células microbianas presentes nos componentes das overdentures nas avaliações foi semelhante (p=0,607) e a microbiota identificada apresentou-se qualitativamente semelhante após cada um dos métodos. Não houve diferença estatisticamente significante entre os diferentes tipos de implantes quanto ao total de células microbianas presentes no sulco peri-implantar e nos componentes das overdentures, identificadas em cada uma das avaliações (p>0,05). As médias das respostas ao questionário de satisfação após ambos os métodos foram altas (acima de 80,0 mm) para todas as questões, porém não houve diferença estatisticamente significante entre as respostas dadas após o uso de ES e WP (p>0,05). Concluiu-se que o método experimental foi eficaz na redução dos parâmetros clínicos avaliados; apresentou ação antimicrobiana mais efetiva na redução da quantidade total de micro-organismos presentes no biofilme subgengival; porém, não apresentou ação antimicrobiana frente aos micro-organismos presentes nos componentes protéticos das overdentures; e proporcionou alto nível de satisfação do paciente. / The maintenance of implant-supported prostheses and peri-implant health is directly related to the success of rehabilitation treatment. The aim of this study was to evaluate, through randomized clinical trial, the efficacy of an experimental method (brushing associated with oral irrigation) in the maintenance of the peri-implant tissues and overdentures. Biofilm removal capacity and oral tissues health maintenance, antimicrobial action and patient satisfaction were analyzed. Thirty-eight patients, users of conventional maxillary complete denture and mandibular overdenture retained by implants or mini-implants and o\'ring-retained system, were selected. The patients utilized the following methods: MB (Control): mechanical brushing method specific brush for dentures, soft bristle toothbrush and dentifrice, and WP (Experimental): association of mechanical brushing with oral irrigation (Waterpik). Patients were instructed to clean their dentures and peri-implant tissues, by means of brushing method for 2 minutes, 3 times a day, and in the experimental group, patients used the oral irrigation, once a day, after brushing, directing the water jet to the gingival margin and the region of the prosthetic components of the overdentures. All patients used both hygiene methods in a random sequence for a period of 14 days, with a 7-day wash-out interposed period. The evaluations were performed before (baseline) and after using each method. Biofilm removal capacity and oral tissues health maintenance were evaluated through Modified Plaque Index (PI), Gingival Index (GI), Probing Depth (PD), and Bleeding on Probing Index (BP). For the antimicrobial action analysis, the subgingival biofilm was collected by means of sterile paper cones and the biofilm present on the overdentures components by microbrush, and the collected samples were processed by the Checkerboard DNA hybridization technique (39 microbial species evaluated). Patients answered to a specific questionnaire using the Visual Analogue Scale (VAS) of 100.0 mm, after application of each method. The data related to clinical parameters and antimicrobial activity were analyzed using the Friedman test (&alpha;=0.05), followed by comparisons using the Wilcoxon test; comparisons between conventional implants and mini-implants were performed using the Mann-Whitney test (&alpha;=0.05). The analysis of the satisfaction questionnaire responses was performed using the Wilcoxon test (&alpha;=0.05). The results showed that, regarding clinical parameters, there was a statistically significant difference between the values obtained at baseline and the values after the evaluated methods (p<0.001); between the MB and WP methods there was no significant difference (PI, GI and PD: p=1.000; BP: p=0.828); there was a statistically significant difference between the different types of implants only of PI after MB (p<0.05). There was a statistically significant difference between the methods (p<0.05) when comparing the values of the total amount of microbial cells in the subgingival biofilm, WP being more effective than MB (p<0.05), but there was no difference between baseline and WP (p>0.05); considering the evaluated microorganisms, WP promoted a more effective reduction than MB only of the C. rectus species (p=0.001). The total amount of microbial cells present in the components of overdentures in the evaluations was similar (p=0.607) and the identified microbiota appeared qualitatively similar after each method. There was no statistically significant difference between the different types of implants for the total microbial cells in the peri-implant sulcus and in the overdentures components identified in each of the evaluations (p>0.05). The means of the satisfaction questionnaire responses after both methods were high (above 80.0 mm) for all the questions, but there was no statistically significant difference between the answers given after the use of ES and WP (p>0.05). It was concluded that the experimental method was effective in reducing the clinical parameters evaluated; presented more effective antimicrobial action in reducing the total amount of microorganisms present in the subgingival biofilm; however, showed no antimicrobial action against microorganisms present in the prosthetic components of the overdentures; and provided high level of patient satisfaction.
214

Estudo comparativo entre duas técnicas para montagem do modelo de gesso de arcadas superiores em articulador semi-ajustável / A comparative study between two techniques to mount the maxillary cast in semi-adjustable articulator

Costa, Rogério Ribas da 20 November 2001 (has links)
Este estudo avaliou a habilidade de duas técnicas, uma convencional e uma de transferência direta do molde, para a montagem do modelo de gesso maxilar no articulador. Um único paciente do sexo feminino, 39 anos, portador de arcada superior de Classe I de Kennedy (desdentado posterior bilateral) foi usado para esta investigação. Foram obtidos 20 modelos de gesso em cada técnica, totalizando 40 montagens nos articuladores. Com o modelo maxilar montado, cada articulador foi fotografado do mesmo lado direito da radiografia em norma lateral da paciente, obtida com o arco facial montado em sua face. As medidas analisadas nos traçados realizados sobre as fotografias e na radiografia, foram obtidas calculando-se o ângulo entre a interseção do plano oclusal da maxila e o plano de referência horizontal (plano de Frankfurt), representado pelo arco facial na radiografia da paciente, comparando-o com o ângulo entre o plano oclusal do modelo de gesso e o ramo superior do articulador em ambas as técnicas, por meio do software UTHSCSA Image Tool. O dados foram submetidos à análise estatística. Os resultados deste estudo demonstraram uma capacidade maior de reprodução daquele ângulo quando uma técnica de transferência direta do molde é usada. Da mesma maneira, foi verificado uma distorção significante na reprodutibilidade dos modelos montados pela técnica convencional. / This study assessed the ability of two techniques to mount the maxillary cast in the articulator, a conventional technique and one of direct transfer of the maxillary arch impression from the patient\'s mouth to the articulator. A single female subject, 39 years old, with a partially edentulous arch, Kennedy´s Class I, was used in this investigation. It was obtained 20 casts in each technique, totaling 40 cast mountings in the articulators. With the maxillary cast mounted, each articulator was photographed in the same right side of the lateral skull cephalometric radiograph of the patient with the face-bow mounted in her face. The measures obtained by the photographic and cephalometric tracings were evaluated by calculating the angle made by the intersection of the maxillary occlusal plane with craniofacial horizontal reference plane (Frankfort´s plane) on the patient´s cephalogram and comparing it with the angle between the occlusal plane of the cast with the upper member of the articulators in both techniques using the UTHSCSA Image Tool computerized program. The measuring data was submitted to the statistical analysis. The results of this study demonstrated a better capacity of reproduction of that angle when a direct transfer technique is used. In the same way, it was found a significant low level of reproducibility in mounting the maxillary cast when a conventional technique is used.
215

Análise comparativa da interface entre intermediários e estruturas fundidas e CAD/CAM em Co-Cr e zircônia antes e após queima de cerâmica e ciclagem mecânica / Comparative analysis of the interface between different abutments and casted or CAD/CAM prostheses before and after ceramic firing and behavior after mechanical cycling.

Coró, Vitor 05 July 2013 (has links)
As próteses sobre implantes apresentam alto índice de sucesso, mas ainda existem relatos de complicações técnicas e mecânicas, principalmente em relação à adaptação e desaperto de parafusos. Técnicas CAD/CAM foram desenvolvidas tentando melhorar adaptação e passividade, e hoje existem vários materiais e sistemas como opção de trabalho. A proposta deste estudo foi avaliar, por meio de leitura em microscópio, a adaptação de próteses de três elementos sobre dois implantes confeccionadas em diferentes materiais, por diferentes técnicas, antes e após a queima de cerâmica. Também foi verificado se o método/material utilizado, assim como o grau de adaptação influenciariam no comportamento das peças frente a um ensaio de fadiga mecânica. Foram formados 5 grupos de 10 amostras (n=10). Após leituras, prensagem de cerâmica e ensaio de fadiga, os dados foram submetidos aos testes ANOVA e Tuckey-Kramers. As médias de desajuste vertical pré e pós aplicação da cerâmica (&mu;m), quando ambos parafusos apertados foram para G1: Estruturas fundidas em Co-Cr com cilindros calcináveis (26,03 ± 18,4) e (36,5 ± 9) G2: Estruturas sobrefundidas em liga de Co-Cr, utilizando cilindros com base de Co-Cr (4,86 ± 5) e (10,5 ± 6); G3: Estruturas fundidas em liga de Co-Cr, associadas à técnica do cilindro cimentado (0 ± 0)e (0 ± 0); G4: Estruturas usinadas em Co-Cr CAD/CAM (0 ± 0) e (2,7 ± 2);G5: Estruturas usinadas em Zircônia CAD/CAM (14,87 ± 9) e (15,2 ± 8). Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado parafusado, os resultados foram para G1: 9,63 ± 1 e 34,8 ± 8; G2: 2,37 ± 5 e 11,9 ± 9; G3: 0 ± 0 e 0 ± 0; G4: 0 ± 0 e 3,4 ± 3; G5: 17,69 ± 1 e 20,8 ± 9. Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado desparafusado, os resultados foram para G1: 124,22 ± 37 e 129,8 ± 37; G2: 64,79 ± 47 e 80,6 ± 46; G3: 12,34 ± 17 e 2,1 ± 3; G4: 3,54 ± 5 e 17,6 ± 8; G5: 37,77 ± 25 e 42,4 ± 19. O torque de desaperto (Ncm) dos parafusos protéticos foi verificado antes e após ensaio de fadiga com 300.000 ciclos. Os valores médios encontrados foram respectivamente: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. Os grupos CC, Co-Cr CAD/CAM e Zi, apresentaram os melhores resultados quanto ao ajuste vertical, seguidos pelo grupo Co-Cr e calcinável. Os grupos CC, Co-Cr e Co-Cr CAD/CAM apresentaram perda de torque dos parafusos protéticos após oensaio de fadiga mecânica. O grupo Zi teve menor perda de torque entretodos grupos, comparando antes e após o teste de fadiga. Nenhum dos grupos apresentou perda de torque suficiente para que a prótese perdesse estabilidade da junção. / The implant-supported prostheses present a high success rate, but there are still reports of technical and mechanical complications, mainly regarding adaptation and loosening of screws. CAD/CAM techniques have been developed trying to improve adaptation and passivity, and today there are many options of materials and systems to work with. The purpose of this study was to evaluate, by microscope, fitting of three elements prostheses retained by two implants, made of different materials, different techniques, before and after ceramic firing. It was also verified if the method/material used, as well as the degree of adjustment would influence on the behavior of the prostheses after a fatigue test. Five groups of ten specimens were formed (n = 10). After reading, ceramic pressing and fatigue test data were submitted to ANOVA and Tukey-Kramer\'s tests. The mean vertical misfit pre and post application of ceramic (&mu;m), whit both screws tightened to G1: Structures casted in Co-Cr with castable cylinders (26.03 ± 18.4) and (36.5 ± 9) G2: Structures casted in Co-Cr, with Co-Cr basis cylinder (4.86 ± 5) (10.5 ± 6); G3: Structures casted in Co-Cr associated with the cemented cylinder technique (0 ± 0) and (0 ± 0); G4: Machined structures in Co-Cr CAD/CAM (0 ± 0) and (2.7 ± 2), G5: Structures machined in zirconia CAD/CAM (14.87 ± 9) and (15.2 ± 8). To the measurement condition of only one side tighted, pre and post ceramic, on the tightned side, the results were G1: 9.63 ± 1 and 34.8 ± 8; G2: 2.37 ± 5 and 11.9 ± 9; G3: 0 ± 0 and 0 ± 0; G4: 0 ± 0 and 3.4 ± 3; G5: 17.69 ± 1 and 20.8 ± 9. To the measurement condition of only one side tightened, pre and post ceramic, on the untightened side, the results were in G1: 124.22 ± 37 and 129.8 ± 37; G2: 64.79 ± 47 and 80.6 ± 46; G3: 12.34 ± 2.1 and 17 ± 3; G4: 5 ± 3.54 and 17.6 ± 8; G5: 37.77 ± 25 and 42.4 ± 19. The loosening torque of the prosthetic screws (Ncm) was checked before and after fatigue test to 300,000 cycles. The mean values were: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. CC groups, Co-Cr CAD/CAM and Zi, showed the best results regarding vertical adjustment, followed by the Co-Cr group and castable. CC groups, Co-Cr and Co-Cr CAD/CAM presented loss of torque after fatigue test. The Zi group showed less loss of torque among all groups, comparing before and after fatigue test. None of the groups showed enough loosening to loose joint stability.
216

Relação da distância interimplantar e altura do ponto de contato na formação de papilas gengivais: estudo em cães / Influence of interimplantar distance and height from the point of contact in the formation of gingival papilae: a study in dogs

Cruvinel, Diogo Rodrigues 24 April 2009 (has links)
Os implantes dentais são considerados uma modalidade de tratamento bastante previsível para a reposição de dentes perdidos. Os implantes osseointegráveis principalmente quando colocados em regiões anteriores devem oferecer, além de excelente função, ótima estética, e fonética. Sendo que o critério para o sucesso envolve o estabelecimento do contorno de tecido mole, apresentando a área interproximal intacta. O propósito deste estudo foi avaliar a influência das diferentes distâncias (3 e 5 mm) entre a crista óssea e ponto de contato interdental, na formação de papila gengival associado à presença de diferentes distâncias (2 e 3 mm) entre implantes contíguos e na região de extremo livre mesial e distal. Foram selecionados para o experimento 8 cães adultos jovens e executada a exodontia dos 4 pré-molares mandibulares: p1, p2, p3, p4, para cada hemi-mandibula. Três meses após as exodontias foram colocados 3 implantes Replace Select Tapered com superfície tratada e dimensões de 4,3 X 10 mm, em cada hemimandibula animal. O primeiro implante foi colocado a 10 mm da distal do canino remanescente, o segundo (intermediário) foi colocado a 2 mm do primeiro e o terceiro implante (posterior) foi colocado a 3 mm do segundo. Foi iniciada a reabilitação protética, no dia da colocação dos implantes. Primeiramente foi feita a moldagem para a confecção das próteses metálicas. As coroas metálicas definitivas, confeccionadas, apresentaram distância do ponto de contato à crista óssea de 3 e 5 mm lado esquerdo e direito respectivamente. Ao completar 12 semanas pós-colocação das próteses definitivas, os animais foram sedados e as análises clínicas foram executadas. Esta avaliação foi feita a partir da utilização de um compasso de pontas secas, medindo as distâncias entre os pontos de contato e as pontas das papilas (PC - P) e dos pontos de contato aos extremos livres mesial e distal (PC - ELM e PC ELD respectivamente). O delineamento das situações experimentais foi executado levando em consideração as associações das diferentes distâncias interimplantar com as diferentes distâncias do ponto de contanto a crista óssea, assim encontramos a seguinte disposição: Situação 01 (PC3A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado esquerdo; Situação 02 (PC3B) Distância do ponto de contato, a gengiva interproximal sendo à distância interimplantar de 2 mm, lado esquerdo da mandíbula; Situação 03 (PC3C) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado esquerdo da mandíbula; Situação 04 (PC3D) Distância do ponto de contato a gengiva do extremo livre distal, do lado esquerdo Situação 05 (PC5A) Distância do ponto de contato a gengiva do extremo livre mesial, do lado direito; Situação 06 (PC5C) Distância do ponto de, a gengiva interproximal sendo a distância interimplantar de 3 mm, lado direito da mandíbula; Situação 07 (PC5B) Distância do ponto de contato, a gengiva interproximal sendo a distância interimplantar de 2 mm, lado direito da mandíbula e Situação 08 (PC5D) Distância do ponto de contato a gengiva do extremo livre distal, do lado direito. Ao analisar as medias das alturas gengivais temos: PC3A a média de 2,9±0,5 mm; PC3D 2,5±0,5 mm; PC3B 1,8±0,6 mm; PC3C 2,0±0,8 mm; PC5A 3,0±0,5 mm; PC5D 3,5±0,4 mm; PC5C 3,6±0,4 mm e PC5B 3,9±0,7 mm. Como as premissas de aderência à distribuição normal, independência entre os indivíduos estudados e pareamento entre as diferentes etapas foram cumpridas, empregou-se a análise de variância (ANOVA) para mensurações repetidas, a dois fatores. Nos casos em que a ANOVA encontrou diferença entre as situações testadas, uma comparação a posteriori foi executada por meio do teste de Bonferroni. O nível de significância empregado para todos os testes foi de 0,05 (5%). Logo as distâncias de 2,0 e 3,0 mm entre implantes contíguos não apresentaram diferença significativa na formação de papila quando as restaurações protéticas são confeccionadas com 3 ou 5 mm de distância entre o ponto de contato e a crista óssea. Considerando a provável reabsorção óssea em ambos os grupos, quando a distância do ponto de contato à crista óssea foi inicialmente de 3 mm esta condição apresentou melhores resultados na formação de papilas do que a distância de 5 mm em todas as situações estudadas. A presença do ponto de contato de 3 mm influência positivamente na formação de papila, quando comparada com as regiões de extremo livre. / The dental implants are considered a form of treatment rather predictable for replacement of lost teeth Implants should offer, as well as excellent function, aesthetics and phonetics great, especially when placed in anterior regions, where the criterion for success involves the establishment contour of the soft tissue, showing the area intact interproximal The purpose of this study was to evaluate the influence of different distances between the bone crest and interdentally contact point, with 3 and 5 mm, the formation of gingival papilla associated with the presence of different distances of 2 and 3 mm between implants and the adjacent region of mesial and distal end free. Were selected for the experiment 08 dogs and young adults performed the extraction of the 4 pre molars mandibles: p1, p2, p3, p4, for each hemi-mandible. Three months after the tooth extractions were placed 3 Replace Select Tapered implants with treated surface and dimensions of 4.3 X 10 mm in each animal hemi mandibles. The first implant was placed at 10 mm distal of the canine left, the second (middle) was placed at 2 mm from the first and third implant (back) was placed at 3 mm from the second. Prosthetics rehabilitation has begun on the day of the placement of implants. First was the casting for the manufacture of metal stents, since the provisional prostheses were made of acrylic resin so that the distance between the point of contact and the bone crest is 3 mm on the left side of the mandible and 5 mm on the right. The final metal crowns, made, made from the point of contact to bone crest of 3 and 5 mm. After completing 12 weeks after placement of final prosthesis, the animals were sedated and the clinical tests were performed. This evaluation was made from the use of a dry bar for tips, measuring the distances between the points of contact and the tips of the papillae (PC - P) and the contact points of the mesial and distal ends free (PC - PC and ELM - ELD respectively). The design of the experimental situations was implemented taking into account the associations of different distances interimplantar with different distances from the long bone crest, we found the following provision: Location - 01 (PC3A) Distance from the point of contact to end the free gingiva mesial to the left; Situation - 02 (PC3B) Distance from the point of contact, the gingival interproximal distance being interimplantar of 2 mm, the left side of the mandible; Situation - 03 (PC3C) Distance from the point of contact, the gingival interproximal and interimplantar a distance of 3 mm, the left side of the mandible; Situation - 04 (PC3D) Distance from the point of contact to the extreme free gingival distal to the left position - 05 (PC5A) Distance from the point of contact to the extreme free gingival mesial on the right side; Situation - 06 (PC5C) distance from the interproximal gingival interimplantar the distance of 3 mm, right side of the jaw; Situation - 07 (PC5B) Distance from the point of contact, the gingival interproximal the distance interimplantar of 2 mm, the right side of the mandible and Situation - 08 (PC5D) Distance from the point of contact to free distal end of the gingival on the right side. In examining the measures of gingival heights are: PC3A an average of 2.9 ± 0.5 mm; PC3D 2.5 ± 0.5 mm; PC3B 1.8 ± 0.6 mm; PC3C 2.0 ± 0.8 mm; PC5A 3.0 ± 0.5 mm; PC5D 3.5 ± 0.4 mm; PC5C 3.6 ± 0.4 mm and PC5B 3.9 ± 0.7 mm. As adherence to the assumptions of normal distribution, independence among the subjects studied and matching between the different stages have been completed, using the analysis of variance (ANOVA) for repeated measurements, the two factors. Where ANOVA found the difference between the conditions tested, a posteriori comparison was performed using the Bonferroni test. The significance level used for all tests was 0.05 (5%). Once the distances of 2.0 and 3.0 mm between adjacent implants showed no significant difference in the formation of the papilla when prosthetic restorations are made with 3 or 5 mm distance between the point of contact and the bone crest. Considering the probable bone resorption in both groups, where the distance from the point of contact to the bone crest was originally the condition of 3 mm showed better results in the formation of papillae than the distance of 5 mm in all cases studied. The presence of the point of contact 3-mm positively influence the formation of papilla, when compared with regions of extreme freedom.
217

Análise da distribuição das tensões em restaurações cerâmicas sobre dente natural e implante por meio do método dos elementos finitos /

Freitas Júnior, Amilcar Chagas. January 2008 (has links)
Resumo: As restaurações cerâmicas têm proporcionado resultados satisfatórios estética e biomecanicamente. Porém, a comparação dos dados sobre a distribuição das tensões nos casos de diferentes restaurações suportadas por dente ou por implante é inconclusiva. O objetivo desse estudo foi avaliar, através da análise de elementos finitos bidimensional, a distribuição interna das tensões nos materiais e estruturas de suporte em função de duas possibilidades restauradoras em cerâmica (faceta laminada e coroa total) e dois tipos de suportes (dente natural e implante). Foram confeccionados 8 (oito) modelos (M) no programa AutoCad 2006, variando o tipo de suporte e restauração: MA (controle) - representação do incisivo central maxilar, hígido, seccionado sagitalmente; MB1, MB2 e MB3 - semelhantes ao MA, restaurados com faceta laminada pelo sistema IPS Empress, IPS Empress Esthetic e Laminado Procera, respectivamente; MC1 e MC2 - semelhantes ao MA, com coroa total pelo sistema IPS Empress 2 (MC1) e Procera AllCeram (MC2); MD1 e MD2 - porção coronária semelhante ao MC1 e MC2, respectivamente, com a presença de um implante osseointegrado (Sistema Bränemark - 4,3 X 15,0 mm) e pilar em zircônia. Para análise numérica (Ansys 10.0), os modelos foram carregados (C) sob duas condições (50N): C1 - 45º de inclinação com o longo eixo dental, no terço médio da face palatina; C2 - perpendicular à borda incisal. Adicionalmente, uma terceira condição foi adotada para o MA: C3 - 50N na borda incisal paralelo ao longo eixo dental. Foram obtidas a tensão equivalente de von Mises (σvM) e a máxima tensão principal em tensão (σmax.t) e compressão (σmax.c). Observou-se que C3 proporcionou a menor variação de svM no dente e estruturas de suporte quando comparada à C1 e C2. / Abstract: The ceramics restorations have provided excellent aesthetic and biomechanical clinical results. However, the data about the stress distribution in tooth and implant-supported restorations are inconclusive. Using two-dimensional finite element analysis, the purpose of this study was to evaluate the stress distribution in the materials and support structures based on two ceramics restorative possibilities (laminate veneer and ceramic crown) and two support structures (tooth and implant). 8 models (M) were built in the program AutoCAD 2006, varying the restorations and their support structures: MA (control) - an intact maxillary central incisor in sagittal cut; MB1, MB2 and MB3 - similar to MA, with laminate veneers of IPS Empress, IPS Empress Esthetic and Procera veneer, respectively; MC1 and MC2 - similar to MA, with a full crown of IPS Empress 2 (MC1) and Procera AllCeram (MC2); MD1 and MD2 - coronary portion similar to MC, with an osseointegrated implant (Bränemark System - 4.3 X 15.0 mm) and zircon abutment. To the numerical analysis (Ansys 10.0), the following loadings (L) were performed (50N): L1 - on the medium third of the lingual face, in 45º with the dental long axis; L2 - perpendicular to the incisal edge; L3 - 50N in the incisal edge parallel to the tooth long axis (only for the natural tooth). The von Mises equivalent stress (σvM) and maximum principal stress in tension (σmax.t) and compression (σmax.c) were obtained. It was observed that L3 provided the smallest variation of σvM in the tooth and support structures in comparison with L1 and L2. The beam3 elements used for the periodontal ligament modeling showed an appropriate behavior for parallel loading. In the MB and MC, the ceramics increased the σvM in the adhesive interface, mainly for Procera. In the models with implant, the IPS Empress2 showed higher σvM than that for Procera AllCeram. / Orientador: Eduardo Passos Rocha / Coorientador: Paulo Henrique dos Santos / Banca: Altair Antoninha Del Bel Cury / Banca: Wirley Gonçalves Assunção / Mestre
218

Distribuição de tensões geradas por próteses esplintadas ou individualizadas sobre implantes com reabilitações em diferentes rebordos. Análise pelo método dos elementos finitos / Stress distribution generated by splinted or individualized implant prostheses with rehabilitation in different edges. A finite element analysis

Toniollo, Marcelo Bighetti 28 August 2014 (has links)
O emprego dos implantes ósseointegráveis na odontologia moderna tem conquistado destaque nas reabilitações de forma crescente. Em casos de perda óssea vertical severa, a qual se faz bastante presente em áreas posteriores mandibulares, o uso de implantes curtos e de diâmetro reduzido se faz necessário. Para que a reabilitação mantenha o plano oclusal nivelado, utiliza-se próteses sobre implantes com proporção coroa/implante aumentada, sendo importante avaliar se há sobrecarga das estruturas de suporte, e se convém a esplintagem da infraestrutura reabilitadora. Um dos métodos utilizados atualmente para análise de distribuição de tensões na odontologia é o método dos elementos finitos. Assim, este estudo teve o objetivo geral de comparar o desempenho biomecânico de próteses, esplintadas (PSIE) ou individualizadas (PSII), sobre implantes cone Morse de comprimento regular e curto, em área posterior de mandíbula. Foram usados modelos geométricos tridimensionais de implantes regulares &empty; 4x11 mm e curtos - &empty; 4x5 mm alojados em rebordos representativos do hemi-arco mandibular esquerdo posterior envolvendo o dente 34 adjacente ao espaço anodôntico, desenhados no programa SolidWorks 2007. Os 8 grupos experimentais foram: grupo controle E (3 implantes regulares reabilitados com PSIE), grupo 1E (2 implantes regulares e 1 curto reabilitados com PSIE), grupo 2E (1 implante regular e 2 curtos reabilitados com PSIE) e grupo 3E (3 implantes curtos reabilitados com PSIE); grupo controle I (3 implantes regulares reabilitados com PSII), grupo 1I (2 implantes regulares e 1 curto reabilitados com PSII), grupo 2I (1 implante regular e 2 curtos reabilitados com PSII) e grupo 3I (3 implantes curtos reabilitados com PSII); As alturas dos pilares usados foram 3,5 mm para implantes regulares e 0,8 mm para implantes curtos. Foram simuladas forças oblíquas (45° - linguo-vestibular) de 365N em molares e 200N em prémolares. Análises qualitativas e quantitativas da distribuição de tensões máximas e mínimas principais (ossos cortical e esponjoso) e tensão equivalente de von Mises (implantes, componentes e infraestruturas) foram feitas por meio do programa AnsysWorkbench10.0. Os resultados obtidos permitiram concluir que o uso de PSIE propiciou uma série de vantagens e benefícios com relação à distribuição de tensões nos elementos envolvidos no sistema, sendo benéfica a todos os grupos experimentais do presente estudo, notoriamente ao grupo com presença apenas de implantes curtos, diminuindo as tensões no osso circunjacente aos implantes, principalmente em sua abrangência. Também diminuiu as tensões na superfície dos implantes, na área de transmucoso dos pilares/componentes, na região interna das infraestruturas e sua abrangência ao osso circunjacente aos implantes curtos nos grupos com implantes regulares e curtos. No entanto, nesse mesmo contexto, gerou maior tensão ao osso circunjacente aos implantes regulares intermediários comparativamente aos grupos individualizados. Também favoreceu a diminuição das tensões ao osso circunjacente ao dente adjacente, quando na presença de proporção coroa/implante aumentada. O uso PSII apresentou-se vantajosa na diminuição das tensões na parte superior dos pilares e na área de conexão entre coroas, além do grupo controle, apenas com implantes regulares e próteses de proporção normal, sendo viável sua utilização neste contexto frente às vantagens clínicas não oferecidas pelas próteses esplintadas. / The use of dental implants in modern dentistry has gained prominence in oral rehabilitations. In cases of severe vertical bone loss, which is very much present in mandibular posterior areas, the use of short implants and reduced diameter is necessary. To maintain the occlusal plane level rehabilitation it is necessary the use of prostheses with increased crown/implant ratio , and it is important assess whether there is overhead of supporting structures, and befits splinting the rehabilitating infrastructure. One of the methods currently used to analyze the stress distribution in dentistry is the finite element method. Thus , this study has the overall objective to compare the biomechanical performance of prostheses, splinted (PSIE) or individualized (PSII) over Morse taper implants of regular and short length in the posterior area of the mandible. It were used three-dimensional geometric models of regular implants - &empty; 4x11 mm and short implants - &empty; 4x5 mm housed in representative edges of the posterior left mandibular hemi-arch tooth involving 34 teeth, designed in SolidWorks 2007 program. The 8 experimental groups were: control group E (3 regular implants rehabilitated with PSIE ), group 1E (2 regular and 1 short implants rehabilitated with PSIE) , 2E group (1 regular implant and 2 short implants rehabilitated with PSIE) and 3E group (3 short implants rehabilitated with PSIE); control group I (3 regular implants rehabilitated with PSII), group 1I (2 regular and 1 short implants rehabilitated with PSII), 2I group (1 regular implant and 2 short implants rehabilitated with PSII) and 3I Group (3 short implants rehabilitated with PSII); The pillars heights used for regular implants were of 3.5 mm and 0.8 mm for the short implants. Oblique forces (45° linguo-vestibular) were simulated in molars (365N) and premolars (200N). Qualitative and quantitative analysis of the distribution of maximum and minimum principal stresses (cortical and cancellous bone) and von Mises equivalent stress (implants, components and infrastructure) were made through the software AnsysWorkbench10.0. The results showed that the use of PSIE provided advantages and benefits regarding the stresses distribution in the elements involved in the system, being beneficial to all experimental groups of this study notoriously in the group with only short implants, reducing stresses in the surrounding bone to implants, especially in coverage. Also decreased the stresses on the implants surface, in the transmucosal abutments area, in the inner region of the infrastructure and its reach to the surrounding bone to short implants in groups with regular and short implants. However, in that respect, generated higher stresses to the surrounding bone of intermediate implants compared to the individualized groups. Also favoring a decrease of the stresses to surrounding bone adjacent to the tooth, in the presence of increased crown/implant ratio. The use PSII showed to be advantageous in reducing stresses on top of the abutments and the area of connection between crowns, and in the control group, only with regular implants and prostheses of normal crown/implant ratio, so it can be used in this context facing the clinical advantages not offered by splinted prostheses.
219

Novo formato de pilar protético em zircônia estabilizada por Itría (Y-Tzp) para implantodontia desenvolvido pela técnica de slip casting /

Silva, Lucas Hian da. January 2011 (has links)
Orientador: Rubens Nisie Tango / Banca: Alexandre Luíz Souto Borges / Banca: Sebastião Ribeiro / Resumo: O objetivo deste estudo foi desenvolver um novo formato de pilar protético estético em zircônia (3Y-TZP) visando suprimir a utilização do parafuso trespassante utilizado no formato convencional de pilares protéticos em zircônia. Inicialmente foi feita a caracterização do material utilizado na técnica de colagem de barbotina (slip casting) através da confecção de uma barra que teve suas propriedades mecânicas, módulo de elasticidade (E) e coeficiente de Poisson (), grau de contração e dimensão de suas partículas após sinterização avaliados pelos métodos de frequências naturais de vibração e microscopia eletrônica de varredura (MEV), respectivamente. Previamente à confecção do pilar protótipo, este teve seu comportamento mecânico avaliado e comparado a um pilar de 3YTZP convencional com parafuso trespassante pela análise por elementos finitos (FEA) durante sua instalação em implante e recebendo carga oblíqua simulando força de mastigação (210,5 N). O protótipo foi confeccionado pela técnica de colagem de barbotina em um molde de gesso obtido a partir de uma duplicata ampliada em cera. A densidade final foi avaliada pelo método de Archimedes em água. Obteve-se o módulo de elasticidade de 187,97 ± 4,84 GPa e coeficiente de Poisson de 0,19 ± 0,04 para o material. O grau de contração de sinterização foi de 58 vol% e o tamanho do grão foi de 0,705 ± 0,424 μm. Na análise por FEA verificou-se concentrações de tensões na região inicial da rosca para ambos os pilares, e durante o carregamento foram observadas tensões de tração no lado em que incidiu a carga, com presença de tensões de compressão no lado oposto. Ainda, observou-se durante o carregamento do pilar protético convencional concentração de tensão na região do pescoço do parafuso trespassante. A densidade final obtida para o pilar protótipo em 3Y-TZP foi de 95,68% em ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to develop a new esthetic zirconia (3YYTZP) implant abutment shape to suppress the use of the fixing screw commonly used by the conventional zirconia abutments. A material characterization, Young's modulus (E), Poisson's rate (), shrinkage and particles dimensions after sintering was performed for a bar shape specimen obtained by slip casting evaluated by the natural torsional and flexural vibration frequencies and scanning electron microscope (SEM), respectively. Previously to the prototype abutment confection, its mechanical behavior was evaluated and compared to a conventional zirconia abutment with a fixing screw by finite element analisys (FEA) simulating the abutment installation and oblique loading (210.5 N). The prototype was confectioned by the slip casting technique using a gypsum mould obtained from a wax expanded replica. The abutment had its density measured by Archimedes' method. Through the natural vibration frequencies a Young's modulus of 187.97 ± 4.84 GPa and a Poisson's rate of 0.19 ± 0.04 were obtained for the material. The shrinkage was 58 vol% and the grain size was 0,705 ± 0,424 μm . The FEA showed stress concentration at the first thread pitch for both abutments, and tensile stress concentration were observed at the side that received the oblique load with compressive stress at the opposite side. Whereas, for the conventional abutment model a stress concentration was observed at the screw's stem. The final density for the zirconia prototype abutment was 95.68% from the theoretical density (6.12 g.cm-3). The zirconia abutment obtained by slip casting presented satisfactory physical properties. The suppressing of the fixing screw could provide better performance to the abutment due to the lack of stress concentration in the screw when an oblique load is applied, when evaluated by FEA / Mestre
220

Efeito da ausência de passividade no sistema coroa-implante-parafuso de retenção por meio do MEF-2D /

Gomes, Érica Alves. January 2006 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Flávio Domingues das Neves / Resumo: Objetivo: avaliar o deslocamento e distribuição interna de tensões do sistema coroa/implante/parafuso de retenção e tecido ósseo adjacente, em função de diferentes níveis de desadaptação angular unilateral, por meio do MEF-2D. Materiais e método: foram confeccionados 4 modelos matemáticos, representativos de coroa metálica conectada a implante por meio de parafuso deretenção, inseridos em tecido ósseo, determinando os 4 grupos estudados: Grupo 1 (controle), coroa completamente adaptada ao implante; Grupo 2, 3 e 4, coroa com desadaptações angulares unilaterais de 50æm, 100æm e 200æm, respectivamente. A partir do programa de elementos finitos Ansys, os modelos receberam carga de 133N, com angulação de 30o e deslocamento de 2mm do longo eixo do implante em lado oposto a desadaptação, sendo analisados os mapas de tensões e deslocamento. Resultados: com o aumento das desadaptações angulares, os mapas de tensões mostraram aumento gradativo das tensões na coroa (1056 N/mm2 a 2326N/mm2) e no parafuso de retenção (909.91 N/mm2 a 987.02N/mm2) e uniformidade na distribuição de tensões no implante e tecido ósseo medular. Quanto ao deslocamento, verificou-se inclinação do conjunto de 0.3101mm (controle) a 0.3179mm no grupo 4, em função do carregamento e das desadaptações. Conclusão: a redução do contato unilateral entre a coroa e o implante levou ao deslocamento de todo conjunto e alteração na distribuição e magnitude das tensões ao longo do sistema, principalmente na região da coroa e parafuso de retenção, sendo que, de modo geral, as desadaptações angulares unilaterais de 100æm e 200æm mostraram maiores valores de tensões em relação ao controle. / Abstract: Objectives: the aim of this study was to evaluate the displacement and stress inner distribution of the prostheses/implant/abutment screw set and surrounding bone, with prostheses presenting different levels of angular misfit unilateral through FEA-2D. Materials and methods: four mathematic models were made, representing metal prostheses in connection of the implant through abutment screw, inside bone tissue, determining 4 groups: Group 1 (control) prostheses fit on the implant; Groups 2, 3 and 4, prostheses with angular misfit unilateral of 50æm, 100æm and 200æm, respectively. It was applied a load of 133N with 30o angulation and off-axis at 2mm of long axis of the implant in opposite direction of misfit on the models, through finite element program Ansys. Results: with upper of angular misfit, the stress maps showed gradual increased of prostheses stress (1056N/mm2 at 2326N/mm2) and uniform stress distribution in the implant and trabecular bone. About the displacement, observed inclination of the set of 0.3101mm (control) at 0.3179mm in the group 4 due to loading and misfit. Conclusions: the lower of the unilateral contact between prostheses and implant proportionate the displacement of all set and the distribution and magnitude alterations of the stress of all the system, principally in the prostheses and abutment screw regions; as a general rule, the angular misfit unilateral of the 100æm and 200æm showed higher stress values in relation to the control. / Mestre

Page generated in 0.0924 seconds