• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 232
  • 17
  • 12
  • 12
  • 12
  • 12
  • 11
  • 7
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 267
  • 267
  • 220
  • 218
  • 79
  • 76
  • 74
  • 74
  • 64
  • 60
  • 57
  • 54
  • 34
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Análise da desadaptação marginal vertical e horizontal de infraestruturas de próteses fixas implantossuportadas confeccionadas através de diferentes técnicas /

Gomes, Jéssica Marcela de Luna. January 2018 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientadora: Sandra Lúcia Dantas de Moraes / Banca: Fellippo Ramos Verri / Banca: Mônica Maria Albuquerque Pontes / Resumo: O objetivo deste trabalho foi avaliar a desadaptação marginal vertical, horizontal e interna de infraestruturas e próteses fixas implantossuportadas confeccionadas através de diferentes técnicas. Além disso, realizar uma revisão sistemática e meta-análise avaliando o efeito da soldagem de infraestruturas de próteses fixas implantossuportadas em uma melhor adaptação quando comparada as infraestruturas confeccionadas em monobloco. Um total de 30 infraestruturas foram confeccionadas e divididas em 3 grupos: G1) Técnica convencional da cera perdida (n=10); G2) CAD/CAM (n=10); G3: CAD/CAM + Técnica da cera perdida (n=10). Uma matriz foi utilizada para simular uma prótese fixa implantossuportada de três elementos com um pôntico central. A infraestrutura do grupo G1 foi confeccionada em Ni-Cr, do grupo G2 em zircônia e G3 fresada em cera e fundida em Ni-Cr. Em todos os grupos a desadaptação marginal vertical e horizontal (subcontorno e sobrecontorno) foi avaliada através de um microscópio óptico tridimensional (Quick Scope, Mitutoyo). A revisão sistemática seguiu o critério PRISMA e está cadastrada na plataforma PROSPERO (CRD81865) e a busca foi realizada nas bases de dados Pubmed/MEDLINE, Embase and The Cochrane Library com artigos publicados até novembro de 2017. A questão PICO foi: "A técnica do ponto de solda contribui para uma melhor adaptação quando comparada a confecção em monobloco de infraestruturas e próteses fixas implantossuportadas?". O estudo in vitro demonstrou maior ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the marginal vertical, horizontal and internal misfit of implant-supported prostheses made through different techniques. In addition, to perform a systematic review and meta-analysis evaluating the effect of the welding technique on fixed prosthesis implants supported in make a better adaptation when compared the infrastructures made in one piece cast. A total of 30 infrastructures were made and divided into 3 groups: G1) Conventional- lost wax technique (n = 10); G2) CAD/CAM (n = 10); G3: CAD/CAM + lost wax technique (n = 10). A reference model was used to to simulate a 3-unit implant-supported fixed prostheses with a central pontic. In the G1 group the frameworks were made of Ni-Cr alloy, G2 group in zirconia and G3 milled in wax and fused in Ni-Cr alloy. In all groups, vertical and horizontal marginal misfit (under-contour and over-contour) was evaluated using a 3D optical microscope (Quick Scope, Mitutoyo, Japan). The systematic review and meta-analysis followed the PRISMA criteria and is registered on the PROSPERO (CRD81865). The search was performed in the Pubmed/MEDLINE, Embase and The Cochrane Library databases with selection of articles published until November 2017. The PICO question was: "The welding technique contributes to a better adaptation when compared to the one-piece cast frameworks of implant-supported prostheses?" The in vitro study showed a higher value of vertical marginal misfit for the G3 group (83.5μm), followed ... (Complete abstract click electronic access below) / Mestre
172

Avaliação do exame radiográfico convencional e digital e digital no diagnóstico da adaptação entre implantes dentários e protéticos

Duarte, Glauber Vieira January 2007 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:44:03Z No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:01:18Z (GMT) No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) / Made available in DSpace on 2013-05-16T18:01:18Z (GMT). No. of bitstreams: 1 Dissertacao Glauber Duarte.pdf: 759281 bytes, checksum: 38271c0a48d32eb71858d76a5872d689 (MD5) Previous issue date: 2007 / A Implantologia é uma das modalidades de reabilitação bucal, inclusive pela alta taxa de sucesso das próteses implanto-suportadas. No entanto, estão sujeitas a alguns problemas exclusivos, como o afrouxamento do parafuso e a fratura do parafuso de fixação. A adaptação marginal de um pilar protético sobre o implante é imprescindível para que muitas destas falhas não ocorram. Além disso, desadaptações e cavidades entre estes componentes podem favorecer o acúmulo de bactérias e causar reações inflamatórias nos tecidos periimplantares. O estudo da adaptação marginal entre estes componentes faz parte de uma linha de pesquisa, com o objetivo de estabelecer um método diagnóstico padronizado, eficaz e reprodutível de avaliação. O presente estudo propôs-se a verificar a validade do método radiográfico convencional e sistema digital Digora, quanto à capacidade diagnóstica da adaptação marginal de cinco pilares protéticos, em titânio Procera Alltitan®, com diferentes aberturas entre o implante e o pilar protético. Os pilares foram aparafusados em um implante, que foi posteriormente fixado a uma base metálica hexagonal, permitindo a padronização das tomadas radiográficas e da avaliação microscópica. Os pilares foram avaliados quanto a sua adaptação no implante, utilizando um microscópio óptico comparador (Mitutoyo®), utilizado como padrão-ouro do estudo. Foram utilizados matrizes de poliéster em tiras com o intuito de obter aberturas marginais padronizadas de 50µm, 100µm, 150µm e 200µm, considerando que cada tira possui uma espessura de 50µm. Em cada sistema foram realizadas 75 tomadas radiográficas (15 de cada grupo de abertura marginal), obtendo imagens com cinco tipos de adaptação (adaptado, 50µm, 100µm, 150µm e 200µm). Deste modo, foram avaliados 150 pontos proximais, em cada sistema radiográfico. Dois radiologistas avaliaram as imagens e para a análise estatística foi utilizada uma matriz de decisões para a realização dos testes diagnósticos de: sensibilidade, especificidade, acurácia, valor preditivo positivo e negativo e a medida estatística Kappa. Os resultados obtidos indicaram que os sistemas radiográficos, convencional e digital, possuem alta sensibilidade, especificidade, acurácia, valores preditivos e bom nível de concordância com o grupo-ouro, com uma discreta, mas não relevante, redução da eficácia diagnóstica do sistema digital. Observou-se que os sistemas radiográficos avaliados são excelentes ferramentas de diagnóstico quando aberturas marginais maiores que 50µm não são aceitáveis. Deve-se considerar que o sistema radiográfico digital Digora® possui grandes vantagens sobre o sistema convencional, como a redução da dose de radiação, a eliminação de erros humanos durante o processamento e a economia de tempo. Deste modo, o sistema Digora pode ser incluído como uma ferramenta de grande importância na reabilitação protética sobre implantes. / Salvador
173

Influência da altura da coroa em implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais

Moraes, Sandra Lúcia Dantas de [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T18:46:01Z : No. of bitstreams: 1 moraes_sld_dr_araca.pdf: 1714349 bytes, checksum: d5ff02883440cb484b8e2bd8528c5f78 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração... / The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below)
174

Estudo da atividade antifúngica in vitro do óleo essancial de Schinus terebinthifolius Raddi contra espécies de Candida isoladads da cavidade bucal de usuários de prótese

Pérez, Ana Luiza Alves de Lima 20 January 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-03-06T13:42:11Z No. of bitstreams: 1 arquivo total.pdf: 3124767 bytes, checksum: 920ef6140aafef097406f7ff339fa3eb (MD5) / Made available in DSpace on 2017-03-06T13:42:11Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 3124767 bytes, checksum: 920ef6140aafef097406f7ff339fa3eb (MD5) Previous issue date: 2016-01-20 / Introduction: The phytotherapy has encouraged the evaluation of different herbal products activity to control dental problems, by creating new strategies for the chemical control of oral cavity infections, in an attempt to overcome the drawbacks and weaknesses of market products. Objective: To isolate, identify Candida genus yeasts from denture wearers (removable partial dentures or complete dentures) and evaluate the in vitro antifungal activity of an essential oil extracted from the leaves of Schinus terebinthifolius Raddi. Materials and Methods: It was collected biological material from 23 prosthesis wearers and the identification of yeasts was based on macro and micro-morphology, physiological and biochemical tests. In the antifungal activity tests of S. terebinthifolius Raddi was used four strains of Candida albicans (C. albicans LM-1A, C. albicans LM-3A, C. albicans LM-16B, C. albicans LM-19A), four strains of Candida tropicalis (C. tropicalis LM-2A, C. tropicalis LM-7A, C. tropicalis LM-11A, C. tropicalis LM-13A) of yeasts isolated and identified by biological material collect and standard strains of the american collection ATCC (American Type Culture Collection): C. albicans ATCC 76485 and C. tropicalis ATCC 13803. The sensitivity profile to synthetic antifungal was evaluated by diffusion technique in solid medium suitable for antifungal susceptibility test. The antifungal agents used were amphotericin B (100 μg), fluconazole (25 μg), itraconazole (10 μg), miconazole (50 μg), nystatin (100 I.U.), ketoconazole (50 μg). It was determined the minimum inhibitory concentration (MIC) of essential oil by the microdilution technique and calculated the minimum fungicidal concentration (MFC) by subculture on Sabouraud Dextrose Agar (SDA). Results: Most of the denture wearers were female (78%) and the average age was 48 years and two months. C. albicans and C. tropicalis were the most prevalent species in samples taken in the palatal mucosa (17.39% each) and the bases of prostheses (21.73% each). The antifungal that all strains tested were sensitive to was amphotericin B followed by nystatin, ketoconazole and miconazole with respectively 90%, 80%, 50% of the susceptible strains. Most strains (90%) were resistant to fluconazole and all were to itraconazole. The MIC values varied from 128μg/mL to 256μg/mL, being determined the MIC100% as 256μg/mL. For nystatin, the MIC100% was 16μg/mL. The MFC/MIC ratio indicates fungicidal activity against 80% of the strains tested and is considered fungistatic against C. tropicalis LM-7A and C. tropicalis LM-13A. For nystatin, indicated fungicidal activity against all tested strains. Conclusion: The most prevalent species in denture wearers were C. albicans and C. tropicalis, with a varied susceptibility profile compared to synthetic antifungal, highlighting a pattern of resistance of some strains, particularly to fluconazole and itraconazole. The essential oil of S. terebinthifolius Raddi showed fungicidal activity against most of the strains tested. / Introdução: A fitoterapia tem estimulado a avaliação da atividade de diferentes produtos à base de plantas para o controle de problemas bucais, visando criar novas estratégias para o controle químico das infecções da cavidade bucal, na tentativa de suprir os incovenientes e fragilidades dos produtos do mercado. Objetivo: isolar, identificar leveduras do gênero Candida da cavidade bucal de usuários de prótese (parcial e total removível) e avaliar a atividade antifúngica in vitro do óleo essencial extraído das folhas de Schinus terebinthifolius Raddi (aroeira). Materiais e Métodos: Foram coletados material biológico de 23 usuários de prótese e a identificação das leveduras foi realizada com base na macro e micromorfologia, provas fisiológicas e bioquímicas. Para os ensaios da atividade antifúngica de S. terebinthifolius Raddi foram utilizadas quatro cepas de Candida albicans (C. albicans LM-1A, C. albicans LM-3A, C. albicans LM-16B, C. albicans LM-19A), quatro cepas de Candida tropicalis (C. tropicalis LM-2A, C. tropicalis LM-7A, C. tropicalis LM-11A, C. tropicalis LM-13A) de leveduras isoladas e identificadas da coleta do material biológico e cepas padrão da coleção americana ATCC (American Type Culture Collection) C. albicans ATCC 76485 e C. tropicalis ATCC 13803. O perfil de sensibilidade aos antifúngicos sintéticos foi avaliado pela técnica de difusão em meio sólido indicada para antifungigrama. Os antifúngicos utilizados foram anfotericina B (100 μg), fluconazol (25 μg), itraconazol (10 μg), miconazol (50μg), nistatina (100 U.I.), cetoconazol (50μg). Foi determinada a concentração inibitória mínima (CIM) do óleo essencial e da nistatina (controle) pela técnica da microdiluição e calculada a concentração fungicida mínima (CFM) através do subcultivo em Agar Sabouraud Dextrose (ASD). Resultados: A maioria dos usuários de prótese eram do sexo feminino (78%) e a média de idade de 48 anos e dois meses. C. albicans e C. tropicalis foram as espécies mais prevalentes nas coletas realizadas nas mucosas palatinas (17,39% cada) e nas bases das próteses (21,73% cada). O antifúngico que todas as cepas testadas apresentaram-se sensíveis foi a anfotericina B, seguida da nistatina, cetoconazol e miconazol com respectivamente 90%, 80%, 50% das cepas sensíveis. A maioria das cepas (90%) foram resistentes ao fluconazol e todas foram ao itraconazol. Os valores da CIM do óleo essencial variaram entre 128μg/mL (CIM60%) e 256μg/mL (CIM100%). Para a nistatina a CIM100% foi de 16μg/mL. A relação CFM/CIM do óleo essencial indica atividade fungicida frente a 80% das cepas testadas, sendo considerada fungistática diante da C. tropicalis LM-7A e C. tropicalis LM-13A. E a relação CFM/CIM da nistatina indica atividade fungicida frente a todas as cepas estudadas. Conclusão: As espécies mais prevalentes nos usuários de prótese foi C. albicans e C. tropicalis, com perfil de sensibilidade variado em relação aos antifúngicos sintéticos, com destaque para um padrão de resistência de algumas cepas, especialmente ao fluconazol e itraconazol. O óleo essencial de S. terebinthifolius Raddi apresentou atividade fungicida sobre a maioria das cepas testadas.
175

Efeito de duas técnicas de gradação da zircônia no limite de fadiga de próteses parciais fixas monolíticas de três elementos /

Rocha, Regina Furbino Villefort. January 2016 (has links)
Orientador: Luiz Felipe Valandro Soares / Coorientadora: Renata Marques de Melo Marinho / Banca: Marco Antonio Bottino / Banca: Paulo Francisco César / Banca: Estevam Augusto Bonfante / Banca: Lilian Costa Anami / Resumo: O objetivo deste estudo foi avaliar os efeitos de duas técnicas de gradação da zircônia no limite de fadiga de próteses parciais fixas (PPFs) de 03 elementos. Blocos pré-sinterizados de 3Y-TZP (zircônia policristalina parcialmente estabilizada por 3% mol de ítria) foram fresados para obter 69 PPFs, que foram divididas em 3 grupos (n = 23). O grupo controle (CTL) foi sinterizado e glazeado odedecendo os parâmetros usuais. Nos dois grupos experimentais as PPFs receberam sílica/vidro antes da sinterização. O grupo sílica sol-gel (SSG) foi graduado pela rota de processamento sol-gel, enquanto o grupo vidro-zircônia-vidro (GZG) foi graduado pela técnica de suspensão (slurry). Os grupos graduados não receberam a camada de glaze após a sinterização. Todas as PPFs foram cimentadas nos pilares de compósito com cimento resinoso de dupla polimerização, incluídas em poliuretano e armazenadas em água por cinco dias. A carga inicial do teste de fadiga foi calculada com base nos resultados do ensaio monotônico de três amostras de cada grupo. Para determinar o limite de fadiga 20 amostras de cada grupo foram submetidas ao método da escada ou staircase (100.000 ciclos/5 Hz). Os limites de fadiga (em Newton) foram: CTL = 1607,27; SSG = 1824,31; GZG = 2006,57 e o teste de Dixon e Mood indicou diferença estatística entre os grupos (intervalo de confiança de 95%). As infiltrações de sílica e vidro no corpo da zircônia, por dois diferentes métodos de gradação, aumentaram o limite de fadiga de PPFs... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effects of two grading zirconia techniques on the fatigue limit of 3-unit fixed dental prostheses (FDPs). Presintered blocks of 3YTZP (3 mol% yttria-stabilized tetragonal zirconia polycrystal) were milled to obtain sixty-nine 3-unit FDPs, which were divided into three groups (n = 23). The control group (CTL) was sintered and glazed following the usual parameters. In the two experimental groups presintered FDPs received silica/glass before sintering. Silica sol-gel group (SSG) was graded by the sol-gel processing route, while the glasszirconia-glass group (GZG) was graded by a slurry technique. Graded groups did not receive a glaze layer after sintering. All FDPs were then luted with a dual-curing resin cement on composite abutments, embedded in polyurethane and stored in water for five days. The initial load of the fatigue test was calculated based on the results of the monotonic testing applied on three specimens of each group. To determine the fatigue limit, 20 samples of each group were subjected to staircase testing (100,000 cycles/5 Hz). The fatigue limits (in Newtons) were CT = 1607.27, SSG = 1824.31, and GZG = 2006.57, and the Dixon and Mood test indicated statistically significant differences among groups (95% confidence interval). The infiltration of silica and glass on zirconia bulk, by two different grading methods, increased the fatigue limits of monolithic zirconia FDPs / Doutor
176

Cantilever em Próteses : análise da deformação de estruturas metálicas em NiCr, com diferentes configurações, em função da carga aplicada /

Alves, Luciana Mara Negrão. January 2010 (has links)
Orientador: Humberto Gennari Filho / Banca: Maria Cristina Rosifini Alves Rezende. / Banca: Ricardo Shibayama / Resumo: O êxito clínico nos tratamentos com próteses fixas implanto-suportadas com cantilever é determinado pela maneira como o estresse mecânico é transferido ao implante e ao tecido ósseo circundante sem gerar forças de grande magnitude e pelo estado de saúde dos tecidos adjacentes. Nestes tratamentos, as tensões oclusais se concentram nas extensões distais havendo uma maior incidência de fratura da estrutura, na união entre a prótese e o implante mais distal. Reconhecendo a influência do desenho da estrutura do cantilever sobre os implantes, bem como a necessidade dessas terem formatos que facilitem a higienização e manutenção do tecido periimplantar, o objetivo desse estudo será analisar a relação entre a força aplicada e a deformação ocorrida em barras para cantilever, com áreas de secção transversal em forma de triangulo, quadrada, semi lua, em L e I, através de uma Máquina de Ensaio Universal "EMIC". Serão confeccionadas 25 barras, em liga de NiCr, divididas em 5 grupos, um para cada formato de barra, com 5 corpos de prova cada um. Uma carga vertical de 200N será aplicada na extremidade do segmento de 15 mm, com velocidade de 0,5mm por minuto. As barras que suportaram uma maior carga foram as em formato quadrado, seguida pela meia lua, L, triangular sendo a em formato de I a que suporta menor força de mordida. Houve diferenças estatisticamente significantes quando comparadas as em formato quadrado em relação às outras formas e as em meia lua também com as outras formas, sendo que as em formato de L, I e triangular não apresentaram diferenças estatisticamente significantes. É importante definirmos corretamente o formato da secção transversal da barra do cantilever de uma prótese, em função de sua relação com a classe de prótese antagônica, para que não haja deformação durante a função proporcionando estruturas leves, confortáveis e com espaço suficiente para higienização / Abstract: The clinical success in treatment with implant-supported fixed prostheses with cantilever is determined by how the mechanical stress is transferred to the implant and the surrounding bone without generating forces of great magnitude and the health of tissues. In these treatments, the occlusal stress focus on the distal extensions and a higher incidence of fracture of the structure, the bond between the prosthesis and the most distal implant. Recognizing the influence of the cantilever design of the structure on implants, and the need to have these formats to facilitate the cleaning and maintenance of peri-implant tissue, the aim of this study will examine the relationship between the applied force and deformation occurred in bars for cantilever with areas of cross section in the shape of triangle, square, half moon, L and I, through a Universal Testing Machine "EMIC". 25 bars will be made in NiCr, divided into five groups, one for each bar shape, with five specimens each. 200N of a vertical load is applied at the end of the segment of 15mm with a speed of 0.5 mm per minute. The bars that bore a greater burden were square in shape, then the half moon, L, and the triangular-shaped supports that I less bite force. There were statistically significant differences when comparing the square in shape relative to other forms and in a half-moon also with other forms, and the L-shaped, triangle and I did not show statistically significant differences. It is important to properly define the shape of the cross section bar of the cantilever of a prosthesis, because of its relationship with the class of prosthesis antagonistic, so that no deformation during function, providing lightweight structures, comfortable with enough space for cleaning / Mestre
177

Avaliação da influência de diferentes materiais oclusais na confecção de próteses fixas implantossuportadas unitárias com diferentes diâmetros dos implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /

Santiago Júnior, Joel Ferreira. January 2010 (has links)
Resumo: A literatura científica ainda é escassa em relação à influência de diferentes materiais na confecção de próteses fixas implantossuportadas unitárias em relação aos diferentes diâmetros dos implantes osseointegrados na distribuição das tensões; as suas manifestações e repercussões na prática clínica ainda não estão totalmente esclarecidas, sendo a fundamentação científica indispensável. Assim, o objetivo desta dissertação foi avaliar a influência do material de revestimento oclusal na confecção de prótese fixa implantossuportada unitária com diferentes diâmetros de implantes osseointegrados. Para o estudo foram elaborados 08 modelos, representando cada qual uma secção de osso mandibular (osso esponjoso e cortical), com a presença apenas de um implante (Conexão Master Screw, Sistemas de Próteses, São Paulo, Brasil) do tipo hexágono externo de 3.75 mm x 10 mm (4 modelos) e de 5.00 mm x 10 mm (4 modelos) com coroas de porcelana feldspática, ou de resina acrílica, ou de resina composta ou coroa liga de NiCr. Para confecção dos modelos foram utilizados os programas de desenho assistido: Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, EUA) e SolidWorks® 2006 (SolidWorks Corp, Massachusetts, USA). Os desenhos tridimensionais foram exportados para o programa de elementos finitos NEI Nastran® 9.0 (Noran Engineering, Inc, EUA), para geração da malha, aplicação da carga e análise. Os resultados foram visualizados através dos mapas de tensão von Mises de cada modelo proposto, a fim de avaliar as variações individuais da distribuição das tensões no implante e na coroa; no osso os resultados foram visualizados através dos mapas de tensão máxima principal. Na carga axial (200 N), o osso cortical não mostrou grandes diferenças entre todos os modelos e o osso trabecular sofreu um aumento das tensões por tração... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The scientific literature is still scarce about the influence of different veneering materials used in fabricating superstructures for implant-retained fixed prostheses in relation to different implant diameters on stress distribution, and the manifestations and implications in clinical practice were not clarified. The aim of this dissertation was to evaluate the influence of occlusal material for single implant-supported fixed prostheses with different implant diameters. For this study were simulated 8 models, representing a section of the mandibular bone (trabecular and cortical bone) with a single external hexagonal implant (Master Screw, Conexão Sistema de Prótese ltda., Sao Paulo, Brazil) of 3.75 x 10 mm (4 models) and 5.00 mm x10 mm (4 models) with a crown with different occlusal materials: feldspathic porcelain crowns, or acrylic resin or composite resin crown or NiCr alloy. The models were designed using computer-aided design softwares : Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA) and SolidWorks® 2006 (SolidWorks Corp., Massachusetts, USA). The three-dimensional designs were exported to the finite element program NEI Nastran® 9.0 (Noran Engineering, Inc, USA) for mesh generation, load application and analysis. The results were visualized through von Mises stress maps of each model, to assess individual variations of the stress distribution on the implant and crown; bone results were visualized through maps of maximum principal stress. In axial loading (200 N), cortical bone showed no significant differences in all models,on the trabecular bone the tensile stress increased, with regular implant diameter. For non-axial loads (100 N), the cortical bone, the tensile stress increased significantly on the side common the load application, when it reduced the implant diameter; in the trabecular bone showed seemed stress patterns, although more... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Fellippo Ramos Verri / Banca: Paulo Sérgio Perri de Carvalho / Banca: Alcides Gonini Júnior / Mestre
178

Influência da inclinação das cúspides, tipo de retenção e envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas sobre implantes /

Rocha, Cibele Oliveira de Melo. January 2015 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Francisco de Assis Mollo Junior / Banca: Ricardo Faria Ribeiro / Resumo: O objetivo do estudo foi avaliar a influência da inclinação das cúspides, do tipo de retenção e do envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas implanto-suportadas. Para o ensaio estático utilizou-se seis grupos (n=10): coroas cimentadas com cúspide de inclinação padrão (CIP) de 33º ou cúspides de inclinação reduzida (CIR) de 20°, parafusadas com o orifício de acesso ao parafuso (OAP) não-restaurado com CIP ou CIR e parafusadas com OAP restaurado com CIP ou CIR. Para o efeito do envelhecimento, 4 grupos foram utilizados (n=20): cimentadas com CIP ou CIR; e parafusadas com OAP não-restaurado com CIP ou CIR, em que 50 % das amostras de cada grupo foram cicladas mecanicamente previamente ao ensaio estático. Coroas de um segundo molar inferior foram confeccionadas sobre análogos de implante hexágono externo 5.0 (Biomet 3i, West Palm Beach, FL). O ensaio estático foi realizado aplicando-se força até a fratura da porcelana e para o efeito do envelhecimento, a ciclagem foi realizada (1 x 106; 125 N; 10Hz) antes do ensaio de resistência máxima à fratura. Após análise estatística observou-se que as médias de resistência à fratura apresentaram efeito significativo para Forma de Retenção (FR) e Inclinação de cúspide (IC) (p<0,01). Para FR apenas as coroas parafusadas não apresentaram diferenças estatísticas entre si (p>0,05), porém ambas apresentaram valores estatisticamente menores do que as cimentadas. Para IC, CIP apresentaram menores valores de resistência à fratura. Após o envelhecimento mecânico foi observado efeito significativo somente para os fatores isolados Forma de Retenção e Inclinação de cúspide (p<0,01), com melhores resultados para coroas cimentadas e CIR, respectivamente. O fator Envelhecimento Mecânico (p=0,659) não apresentou efeito significativo. Diante dos resultados, conclui-se que isoladamente... (Resumo completo, clicar acesso eletrônica abaixo) / Abstract: The aim of this study was evaluate the influence of cusp inclination, type of retention and mechanical aging on fracture strength of implant-supported metal-ceramic (MC) single crowns. To static test, six groups were used (n=10): cemented crowns with 33° standard cusp inclination (SCI) or with 20° reduced cusp inclination (RCI), screwed crowns with screw access hole (SAH) not restored with SCI or RCI and screwed crowns with SAH restored with SCI or RCI. To test aging effect, 4 groups were used (n=20): cemented with SCI or RCI; and screw-retained with SAH not restored with SCI or RCI, in which 50% of specimens of each group were submitted to mechanical aging previously to static test. Crowns of a lower second molar were made on the analog implant external hexagon 5.0 (Biomet 3i, West Palm Beach, FL). The cycling (1.106; 125N; 10Hz) will be performed before the fracture resistance test. The static test was performed in a universal testing machine EMIC DL2000, with load application until porcelain failure. After statistical analysis it was observed that the mean fracture resistance of porcelain showed significant effect (p<0.01), to type of retention (TR) and cusp inclination (CI), respectively. To TR, screwed crowns did not show statistical differences (p>0.05), however, both two showed statistically lower values than cemented. To CI, crowns with SCI showed lower values of fracture resistance. After mechanical aging, TR and CI showed significant effect (p<0.01), with better results to cemented crowns and RCI, respectively. The factor mechanical aging did not show significant effect (p=0.659). According to these results, it was concluded that alone, type of retention and the cusp inclination showed influence on fracture resistance of MC crowns, being cemented crowns and reduced cusps mechanically more resistant against a static and cyclic load. The mechanical aging had no significant... (Complete abstract electronic access below) / Mestre
179

Influência da altura da coroa em implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /

Moraes, Sandra Lúcia Dantas de. January 2011 (has links)
Resumo: Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração ... (Resumo completo, clicar acesso eletrônco abaixo) / Abstract: The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Jorge Vicente Lopes da Silva / Banca: Fellipo Ramos Verri / Banca: Regina Tamaki / Banca: Estevão Tomomitsu Kimpara / Banca: Cátia Maria Fonseca Guerra / Doutor
180

Avaliação da resistência ao cisalhamento de sistemas para reparo em metalocerâmicas /

Santos, Juliana Gomes dos. January 2004 (has links)
Orientador: Renata Garcia Fonseca / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: O reparo em próteses metalocerâmicas é um procedimento útil em determinadas situações clínicas. Recentemente surgiram no mercado alguns materiais designados para tal finalidade que, segundo seus fabricantes, são promissores. Neste trabalho foi avaliada a resistência ao cisalhamento de determinados sistemas de reparo para metalocerâmicas. Foram confeccionadas amostras cilíndricas em liga de NiCr (Vera Bond II) e em porcelana feldspática (Noritake). Após inclusão destas em anel de PVC, suas superfícies foram lixadas (320) e, com auxílio de matriz bi-partida (5 mm diâmetro e 2 mm altura), receberam um dos seguintes tratamentos (n=10): 1) sistema Clearfil SE Bond/Clearfil AP-X (Kuraray), 2) sistema Bistite II DC/Palfique (Tokuyama), 3) sistema Cojet Sand/Z100 (3M-ESPE), 4) jateamento com Al2O3 e sistema Scotchbond Multi Uso Plus/Z100 (3M-ESPE) (grupo controle), e 5) jateamento com Cojet Sand e sistema Scotchbond Multi Uso Plus/Z100. Os corpos-de-prova foram armazenados por 24 horas em água destilada a 37ºC, termociclados (1.000 ciclos - 5º a 55ºC) e, então, deixados nas condições descritas acima por mais 8 dias. O ensaio foi realizado em máquina MTS 810 com velocidade de 0,5 mm/min. Os valores originais foram submetidos à análise de variância (ANOVA) e teste de Tukey. No metal, as médias de resistência dos grupos de 1 a 5 foram respectivamente de 18,40 MPa (B), 8,57 MPa (D), 25,24 MPa (A), 16,26 MPa (BC) e de 13,11 MPa (C) (valor crítico 3,2). Em porcelana, foram de 16,91 MPa (B), 18,04 MPa (AB), 19,54 MPa (AB), 21,05 MPa (A) e de 16,18 MPa (B) (valor crítico 3,7). A melhor opção mediante exposição em metal foi o sistema Cojet Sand. Em porcelana, os sistemas Scotchbond Multi Uso Plus associado ao jateamento com Al2O3, Cojet Sand e Bistite II DC apresentaram os melhores resultados. / Abstract: Fracture of porcelain in metal-ceramic restorations is a common clinical problem and sometimes the repair is a useful solution. Recently some new repair materials with promising results according to their manufactures are available. The aim of this study was to evaluate the shear bond strengths of porcelain repair systems. Fifty disks in NiCr alloy (Vera Bond II) and in feldspatic porcelain (Noritake) were made. The specimens were included in acrylic resin and the surfaces were ground with 320-grit silicon carbide paper. Metal and porcelain specimens were divided into five groups of ten each and the bonding sites received one of the following treatments: 1) Clearfil SE Bond/Clearfil AP-X (Kuraray), 2) Bistite II DC/Palfique (Tokuyama), 3) Cojet Sand System/Z100 (3M-ESPE), 4) air-abrading with Al2O3 and Scotchbond Multi Purpose/Z100 (3M-ESPE) (control group) and 5) air-abrading with Cojet Sand and Scotchbond Multi Purpose/Z100. After storage for 24 hours in distilled water at 37°C, thermocycling (1.000 cycles - 5º and 55ºC) and storage for more 8 days at the same conditions above, the shear bond strength test was performed in a testing machine MTS 810 at a crosshead speed of 0.5mm/min until fracture. Statistical analysis of the data was accomplished by analysis of variance (ANOVA) and Tukey's test. In metal, the bond strengths of groups 1 to 5 were, respectively 18,40 MPa (B), 8,57 MPa (D), 25,24 MPa (A), 16,26 MPa (BC) and 13,11 MPa (C). In porcelain, the bond strengths of the five groups were 16,91 MPa (B), 18,04 MPa (AB), 19,54 MPa (AB), 21,05 MPa (A) and 16,18 MPa (B). The best option when occurs metal exposure is Cojet Sand System. In porcelain, air-abrading with Al2O3 and Scotchbond Multi Purpose, Cojet Sand System and Bistite II DC showed the best results. / Mestre

Page generated in 0.1396 seconds