• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 204
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 207
  • 94
  • 35
  • 28
  • 26
  • 22
  • 20
  • 20
  • 19
  • 19
  • 19
  • 18
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Estudo de perfusão e viabilidade miocárdicas por ressonância magnética em pacientes com doença renal crônica candidatos a transplante renal / Assessment of myocardial perfusion and viability using cardiovascular magnetic resonance in patients with end-stage renal disease

Joalbo Matos de Andrade 22 August 2006 (has links)
INTRODUÇÃO: A incidência de doença arterial coronária em candidatos a transplante renal é alta, sendo a principal causa de mortes neste grupo de pacientes. Os resultados obtidos com exames não invasivos usados na detecção de doença arterial coronariana destes pacientes têm-se mostrado variados e, de modo geral, insatisfatórios para uma condição clínica considerada grave. A ressonância magnética cardiovascular é utilizada cada vez mais no estudo de doença arterial coronária na população geral, apresentando bons resultados na identificação de isquemia e de fibrose miocárdica. Entretanto, este método, até o momento, não foi avaliado neste grupo de pacientes. O objetivo deste trabalho é avaliar a capacidade da ressonância magnética cardíaca em detectar doença arterial coronária em candidatos a transplante renal sob dois diferentes aspectos: diagnóstico de lesão coronariana significativa (redução do diâmetro luminal maior ou igual a 70%), avaliada pela alteração da perfusão miocárdica, comparando os resultados com a cintilografia e tendo a angiografia coronária como padrão de referência; e detecção de infarto miocárdico silencioso, comparando com a eletrocardiografia e cintilografia, tendo a ressonância magnética cardiovascular com a técnica de realce tardio como padrão de referência. MÉTODOS: Durante o período de janeiro de 2002 e janeiro de 2004 foram estudados 80 candidatos a transplante renal que apresentavam ao menos um dos seguintes critérios de inclusão: 1. idade igual ou acima de 50 anos; 2. diabete melito; 3. história ou evidência clínica de doença cardiovascular. Todos os pacientes foram encaminhados para serem submetidos a exames de eletrocardiografia, cintilografia, ressonância magnética cardiovascular e angiografia coronária no período máximo de até um ano entre os exames. Na pesquisa de alteração da perfusão miocárdica, comparou-se ressonância magnética cardiovascular com cintilografia em 76 pacientes, tendo a angiografia coronária como padrão de referência na identificação de lesão coronária significativa (estenose igual ou maior que 70% da luz vascular). Na identificação de infarto miocárdico silencioso, comparou-se a ressonância magnética cardiovascular com a eletrocardiografia e cintilografia em 69 pacientes. Os exames foram analisados de modo cego em relação aos resultados dos demais exames. Dados numéricos foram expressos como média, desvio padrão e intervalo de confiança, sendo calculado grau de concordância, testes diagnóstico e de significância entre os métodos. RESULTADOS: Na pesquisa de obstrução coronária significativa, a ressonância magnética cardiovascular apresentou sensibilidade, especificidade e acurácia de 84,1%, 56,3% e 72,4% e a cintilografia miocárdica 65,9%, 68,6% e 67,1%, respectivamente. A ressonância magnética cardiovascular foi significativamente mais sensível que a cintilografia (p=0,039). Na identificação de infarto miocárdico silencioso, o grau de concordância entre a ressonância magnética cardiovascular e o eletrocardiograma foi de 0,28 e entre a ressonância magnética cardiovascular e a cintilografia 0,52. Considerando-se a ressonância magnética cardiovascular como sendo o padrão de referência na identificação de infarto miocárdico silencioso, a sensibilidade, especificidade e acurácia do eletrocardiograma foram de 27,8%, 98% e 79,7% e da cintilografia foram de 66,7%, 87% e 81,2%, respectivamente. CONCLUSÃO: No diagnóstico de lesão coronariana significativa, a ressonância magnética cardiovascular mostrou acurácia similar e maior sensibilidade em relação à cintilografia. Na detecção de infarto miocárdico silencioso, o eletrocardiograma e a cintilografia apresentaram baixa concordância com a ressonância magnética cardiovascular / INTRODUCTION: Coronary artery disease in renal transplant candidates is frequent and is the most common cause of death. Results of standard noninvasive tests for the detection of coronary artery disease in this specific group are incosistent and, overall, considered inadequate for clinical decision making. Cardiovascular magnetic resonance has been used most frequently in the identification of coronary artery disease in the general population with good results in the analysis of myocardial ischemia and fibrosis. However, this method, until now, has not been evaluated for the diagnosis of coronary artery disease in renal transplant candidates. The goal of this study is to assess the capability of cardiovascular magnetic resonance for the detection of coronary artery disease in renal transplant candidates in two different aspects: the diagnosis of significant coronary stenosis (70% or more luminal diameter reduction) assessed by myocardial perfusion abnormalities, comparing the results with scintigraphy and using coronary angiography as the reference method; and the identification of unrecognized myocardial infarction, comparing with electrocardiography and nuclear medicine, using cardiovascular magnetic resonance late enhancement technique as the reference method. METHODS: Between January 2002 and January 2004 we studied 80 renal transplant candidates with at least one of these inclusion criteria: 1. 50 years of age or more, 2. diabetes mellitus, and 3. clinical history or evidence of coronary artery disease. All patients underwent electrocardiogram, nuclear medicine, cardiovascular magnetic resonance and coronary angiography examinations within a maximum period of one year. In the assessment of myocardial perfusion defect, we compared cardiovascular magnetic resonance with scintigraphy in 76 patients with coronary angiography as the reference method in the identification of significant coronary lesion (70% stenosis of the vascular lumen or more). In the identification of unrecognized myocardial infarction, we compared magnetic resonance with electrocardiogram and nuclear medicine in 69 patients. All exams were reviewed by readers blinded to the results of the other exams. Data was presented as mean, standard deviation and confidence interval. Percentual of agreement, diagnostic tests and statistical tests between the exams were calculated. RESULTS: On the assessment of significant coronary stenosis, cardiovascular magnetic resonance showed sensitivity, specificity and accuracy of 84.1%, 56.3%, and 72.4% and nuclear medicine 65.9%, 68.6%, and 67.1%, respectively. Cardiovascular magnetic resonance was significantly more sensitive than scintigraphy medicine (p=0.039). In the identification of unrecognized myocardial infarction, agreement between cardiovascular magnetic resonance and electrocardiogram was 0.28 and between cardiovascular magnetic resonance and scintigraphy was 0.52. Considering cardiovascular magnetic resonance as the reference method in the identification of unrecognized myocardial infarction, the sensitivity, specificity and accuracy of the electrocardiogram were 27.8%, 98% and 79.7%, and for scintigraphy were 66.7%, 87% and 81.2%, respectively. CONCLUSION: In the diagnosis of significant coronary stenosis, cardiovascular magnetic resonance showed similar accuracy and higher sensitivity compared to scintigraphy. In the detection of unrecognized myocardial infarction, the electrocardiogram and scintigraphy presented low agreement with cardiovascular magnetic resonance
202

Caracterização do perfil da micro-alternância da onda T na cardiomiopatia hipertrófica / Characterization of the profile of microvolt T-wave alternans in hypertrophic cardiomyopathy

Antunes, Murillo de Oliveira 19 March 2014 (has links)
Introdução: A cardiomiopatia hipertrófica (CMH) é definida, como a hipertrofia miocárdica ocorrida na ausência de doença cardíaca ou sistêmica, sendo a mais prevalente das cardiopatias de transmissão genética e a principal causa de morte súbita em jovens e atletas. A única opção de tratamento para prevenção dessa complicação é a indicação do cardiodesfibrilador implantável (CDI). Alguns marcadores de risco foram identificados, como: pacientes que sobreviveram à parada cardíaca por fibrilação ventricular, episódio de taquicardia ventricular sustentada; história familiar precoce de MSC; síncope inexplicada; espessura septal >= 30 mm; taquicardia ventricular não sustentada (TVNS) no Holter; queda da pressão sistólica (PAS) > 20 mmHg ou aumento < 20 mmHg no esforço. Entretanto, a sensibilidade e especificidade desses critérios são limitadas, tornando necessário o conhecimento de novos métodos diagnósticos com capacidade de predizer MSC. A micro-alternância da onda T (MAOT) é utilizada como ferramenta diagnóstica na estratificação de pacientes com riscos de desenvolver arritmias ventriculares malignas e MSC auxiliando na indicação do CDI. Na CMH há poucos estudos realizados com objetivos e resultados diferentes e, atualmente, uma nova metodologia na realização desses exames foi desenvolvida, não sendo testada nesta população. Os objetivos do presente estudo foram: caracterizar os valores da MAOT pela metodologia Média Móvel Modificada (MMM) e avaliar a associação de seus resultados com os fatores de risco clínicos para MSC. Metodologia: Foram selecionados 132 pacientes com CMH que foram divididos em dois grupos: 1) Alto Risco, 67 pacientes, que apresentavam, pelo menos, um fator de risco para morte súbita cardíaca (história familiar de morte súbita; síncope inexplicada; espessura septal do miocárdio >=30 mm; taquicardia ventricular não sustentada; queda da pressão sistólica no teste de esforço) e 2) Baixo Risco, 65 pacientes, sem fatores de risco. A idade média foi de 37 ± 11,3 anos, sendo 63% do sexo masculino. A média da espessura de septo interventricular foi 23,9 ± 6,2 mm, da fração de ejeção 72 ± 8,1% e 26% apresentavam forma obstrutiva da doença. A MAOT foi avaliada pelo teste ergométrico com protocolo Naughton modificado, com dois fatores de atualização (FaT) 1/8 e 1/32, de forma quantitativa e qualitativa (positivo e negativo) e com três formas de análises: considerando todas as derivações do eletrocardiograma (plano periférico, frontal e ortogonal); desconsiderando os resultados do plano periférico e desconsiderando as derivações ortogonais. Resultados: A aferição da MAOT com FaT 1/8 apresentou maior sensibilidade em comparação com FaT 1/32 (FaT 1/8 MAOTméd. = 69,2 uV a 78,2 uV vs FaT 1/32 MAOTméd. = 33,2 uV a 38,7 uV, p < 0,01), resultando nas análises quantitativas de valores maiores da micro-alternância (MAOTmáx. - FaT 1/8 = 528 uV vs 124 uV = FaT 1/32, p < 0,01) e na análise qualitativa maior número de exames positivos (MAOT positiva - FaT 1/8 = 57,5% vs 19,0% = FaT 1/32). Os pacientes do grupo Alto risco apresentavam maiores valores de MAOT (Alto Risco MAOT média = 101,4 uV vs 54,3 uV Baixo Risco, p < 0,001) e 84% apresentavam exame positivo (56/67). A MAOT mostrou associação significativa com os fatores de risco para MSC: espessura septal >= 30 mm (p < 0,001), TVNS no Holter 24 h (p = 0,001), história familiar de MSC (p = 0,006) e queda da pressão arterial no esforço (p = 0,02). No rastreamento de pacientes de Alto risco, com ponto de corte de 53 uV o teste apresentou sensibilidade e especificidade de 84% e 71%, com acurácia de 0,77 (IC de 95%: 0,69 a 0,86). Conclusões: Os melhores resultados da MAOT pela metodologia Média Móvel Modificada foram encontrados analisando todas as derivações eletrocardiográficas (plano periférico, horizontal e derivações ortogonais), realizados de forma quantitativa, com Fator de Atualização 1/8 e ponto de corte para positividade 53 uV. A MAOT demonstrou associação significativa com a maioria dos fatores de risco clínicos apresentando boa acurácia no rastreamento dos pacientes de Alto Risco para MSC / Introduction: Hypertrophic cardiomyopathy (HCM) is defined as the myocardial hypertrophy in the absence of cardiac or systemic disease, being the most common genetic transmission cardiopathy and responsible for sudden cardiac death (SCD) in young adults and athletes. The first-line treatment option for prevention of SCD is the implantable cardioverter-defibrillator (ICD). Some clinical factors have been identified as high risk for the occurrence of SCD: history of cardiac resuscitation for ventricular fibrillation, episode of sustained ventricular tachycardia, family history of premature SCD, unexplained syncope, ventricular septal thickness >= 30 mm; nonsustained ventricular tachycardia (NSVT) in Holter and inadequate response of blood pressure to exercise: decrease in systolic blood pressure (SBP) > 20 mmHg or increase < 20 mmHg during effort. These criteria, however, are limited in sensitivity and specificity and new diagnostic methods have been required. The microvolt T-wave alternans (MTWA) is used as a diagnostic tool to identify high-risk patients predisposed to malignant ventricular arrhythmias and SCD. Therefore, MTWA may be helpful to indicate ICD. There are no reports in the literature concerning the use of MTWA in HCM. This research aims to evaluate the values of MTWA by modified moving average (MMA) method and the association with clinical factors for SCD. Methods: We enrolled 132 patients with HCM that were divided into two groups: 1) High Risk (HR) group, 67 patients, that had at least one risk factor for sudden cardiac death (family history of SCD; unexplained syncope; ventricular septal thickness >= 30 mm; nonsustained ventricular tachycardia; inadequate response of blood pressure to exercise) and 2) Low Risk (LR) group, 65 patients, without risk factors. The most participants were male (63%) and their mean age was 37 (± 11.3) years. All individuals were evaluated by echocardiography: 23,9 ± 6,2 mm interventricular septal thickness; 72 ± 8.1% ejection fraction and 26% left ventricular outflow gradient of more than 30 mmHg. Patients performed exercise stress testing with modified Naughton Protocol. In the present study, MTWA was assessed with the MMA method, updating factor (UF) 1/8 and 1/32, quantitative and qualitative way (positive and negative). In addition, the values of the MTWA were evaluated in three ways: all the leads of electrocardiogram; disregarding the leads of peripheral plane; disregarding the orthogonal leads. Results: The analysis of MTWA with UF 1/8 showed greater sensitivity compared with UF 1/32 (Mean MTWA, UF 1/8 = 69.2 uV to 78.2 uV vs UF 1/32 = 33.2 uV to 38.7 uV, p < 0.01). Like this, in quantitative and qualitative (positive and negative) analysis of MTWA, the values were larger in the group of UF 1/8 (UF1/8 = 528 uV vs UF 1/32 = 124 uV, p < 0.01/ Positive MTWA, UF 1/8 = 57.5% vs UF 1/32 = 19.0%, p < 0.01). The patients of High Risk group presents higher values of MTWA (HR = 101.4 uV vs LR = 54.3 uV, p < 0.001) and 84% had the positive test. The MTWA was significantly associated with risk factors for SCD: ventricular septal thickness >= 30 mm (p < 0.001), NSVT (p = 0.001), family history of SCD (p = 0.006), inadequate response of blood pressure to exercise (p = 0.02). In the analysis of high risk group, using a cutoff value of 53 uV, we observed a sensitivity of 84%, specificity of 71% and accuracy of 0.77 (95% confidence interval: 0.69 to 0.86). Conclusions: The best results of MTWA by MMA method were found by analyzing all lead ECG (frontal and peripheral plane and orthogonal leads), using UF 1/8, quantitative analysis and cut-off value 53 uV. The MTWA was significantly associated with clinical risk factors, showing a good accuracy, and can be used to effectively select high-risk patients for SCD
203

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Neves, Itamara Lucia Itagiba 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.
204

Proposta de protocolo de telemonitoramento sob demanda de sinais biomédicos usando internet das coisas, computação móvel e armazenamento em nuvem / Protocol proposal for on-demand remote monitoring of biomedical signals using internet of things, mobile computing and cloud storage

Machado, Francisco Muller 28 April 2016 (has links)
Este trabalho apresenta a proposta de um protocolo de comunicação de dados integrando tecnologias de internet das coisas, computação móvel e armazenamento em nuvem, aplicado ao telemonitoramento sob demanda de sinais fisiológicos. O objetivo do trabalho foi adquirir, transmitir, armazenar, receber e permitir a visualização sob demanda, mantendo a integridade da representação do sinal biomédico para a análise médica, sem alterar a mobilidade do paciente em monitoramento. O trabalho utiliza um canal de ECG, para adquirir o sinal de eletrocardiografia do paciente, que é conectado via Bluetooth com um dispositivo de computação móvel. O dispositivo de computação móvel, com acesso a internet sem fio, envia o sinal fisiológico através do protocolo proposto para uma base segura de armazenamento de informações em nuvem, podendo ser acessada sob demanda por um especialista para realizar a avaliação médica. O telemonitoramento sob demanda permite ao especialista: visualizar e analisar dados recentes, como se fosse um monitoramento remoto em tempo real do paciente; e visualizar e analisar dados anteriores que estão armazenados na nuvem, semelhante à análise de um exame realizado previamente. O protocolo proposto possui características de segurança da informação, mantendo a integridade da representação no tempo do sinal fisiológico, ainda que dados sejam corrompidos. O trabalho envolveu o uso de tecnologias recentes aplicadas às necessidades de registros de sinais fisiológicos. Estas tecnologias estão em evolução, os padrões não estão consolidados, ocorrendo alterações à medida que novas necessidades vão sendo apresentadas, assim como novas soluções venham a ser desenvolvidas. Como dispositivo de computação móvel foi utilizado neste trabalho um tablet, podendo ser utilizado um smartphone. O protocolo para este trabalho foi utilizado com o sinal de um canal de eletrocardiografia, podendo ser modificado para atender outras necessidades, incluindo outros sinais fisiológicos. Neste trabalho foi utilizado como sinal fisiológico o sinal de um simulador de ECG. / This work shows a proposal for a data communication protocol integrating internet of things technologies, mobile computing and cloud storage, applied to on-demand remote monitoring physiological signals. The aim of this work was to acquire, transmit, store, receive and allow the on-demand visualization, keeping the integrity of the biomedical signals representation for medical analysis, without changing the mobility of the patient being monitored. The work uses an ECG channel to acquire the patient’s electrocardiography signal, which is linked via Bluetooth to a mobile computing device. The mobile computing device, with wireless internet access, sends the physiological signal through the proposed protocol to a safe base of cloud information storage, which can be accessed on demand by a specialist to do the medical evaluation. On-demand remote monitoring allows the specialist to visualize and analyze recent data, as if it were real time remote monitoring of the patient, and visualize and analyze previous data that are stored in the cloud, similar to an analysis of a previously made exam. The proposed protocol has information security features, keeping the integrity of the time representation of the physiological signal, even if the data are corrupted. The work involved the use of new technologies applied to the necessity of physiological signals record. These technologies are evolving. The patterns are not consolidated, and changes are made as new necessities are presented and new solutions developed. For this work, it was used a tablet as a computing mobile device. However, a smartphone could also be used. The protocol was used with an electrocardiography channel signal, which can be modified to attend other necessities, including other physiological signals. As a physiological signal, for this work, it was used an ECG simulator signal.
205

Classificação automática de cardiopatias baseada em eletrocardiograma

Bueno, Nina Maria 30 October 2006 (has links)
This work is dedicated to study of the recognition and classification of cardiac disease, diagnosised through the electrocardiogram ECG. This examination is normally used in heart medical center, emergency, intensive therapy, and with complement diagnosis in heart disease as: acute myocardium infarction, bundle block branches, hypertrophy and others. The software was developed for support to the model, with focus on extraction of ECG signal characteristics, and an artificial neural network for recognition of diseases. For extraction these characteristics, we have used a auto-regressive model, AR, with the algorithm least mean square LMS, to minimize the minimum error. The neural network, with architecture multilayer perceptron and back propagation algorithm of training, was chosen for the recognition of the standards. The method was showed efficient. / Este trabalho dedica-se ao estudo do reconhecimento e classificação de cardiopatias, diagnosticadas através do exame de eletrocardiografia, ECG. Esse exame é comumente utilizado em visitas a cardiologistas, centros de emergência, centros de terapia intensiva e exames eletivos para auxílio de diagnóstico de cardiopatias como: infarto agudo do miocárdio, bloqueios de ramos, hipertrofia e outros. O aplicativo desenvolvido para apoio ao trabalho focaliza a extração de características do sinal ECG, representado por ciclos e a aplicação destas características a uma rede neural artificial para reconhecimento das cardiopatias. Para extração das características do sinal, utilizamos o modelo matemático de previsão de comportamento de curvas, chamado de auto-regressivo, AR, onde utilizamos o passado histórico recente da curva para determinar o próximo ponto; em nosso caso, utilizamos o algoritmo dos mínimos quadrados para adequação do erro, conhecido como LMS. A rede neural de topologia perceptron multicamadas e com algoritmo de treinamento backpropagation foi escolhida para o reconhecimento dos padrões, pela sua capacidade de generalização. O método se mostrou adequado e eficiente ao objetivo proposto. / Mestre em Ciências
206

Caracterização do perfil da micro-alternância da onda T na cardiomiopatia hipertrófica / Characterization of the profile of microvolt T-wave alternans in hypertrophic cardiomyopathy

Murillo de Oliveira Antunes 19 March 2014 (has links)
Introdução: A cardiomiopatia hipertrófica (CMH) é definida, como a hipertrofia miocárdica ocorrida na ausência de doença cardíaca ou sistêmica, sendo a mais prevalente das cardiopatias de transmissão genética e a principal causa de morte súbita em jovens e atletas. A única opção de tratamento para prevenção dessa complicação é a indicação do cardiodesfibrilador implantável (CDI). Alguns marcadores de risco foram identificados, como: pacientes que sobreviveram à parada cardíaca por fibrilação ventricular, episódio de taquicardia ventricular sustentada; história familiar precoce de MSC; síncope inexplicada; espessura septal >= 30 mm; taquicardia ventricular não sustentada (TVNS) no Holter; queda da pressão sistólica (PAS) > 20 mmHg ou aumento < 20 mmHg no esforço. Entretanto, a sensibilidade e especificidade desses critérios são limitadas, tornando necessário o conhecimento de novos métodos diagnósticos com capacidade de predizer MSC. A micro-alternância da onda T (MAOT) é utilizada como ferramenta diagnóstica na estratificação de pacientes com riscos de desenvolver arritmias ventriculares malignas e MSC auxiliando na indicação do CDI. Na CMH há poucos estudos realizados com objetivos e resultados diferentes e, atualmente, uma nova metodologia na realização desses exames foi desenvolvida, não sendo testada nesta população. Os objetivos do presente estudo foram: caracterizar os valores da MAOT pela metodologia Média Móvel Modificada (MMM) e avaliar a associação de seus resultados com os fatores de risco clínicos para MSC. Metodologia: Foram selecionados 132 pacientes com CMH que foram divididos em dois grupos: 1) Alto Risco, 67 pacientes, que apresentavam, pelo menos, um fator de risco para morte súbita cardíaca (história familiar de morte súbita; síncope inexplicada; espessura septal do miocárdio >=30 mm; taquicardia ventricular não sustentada; queda da pressão sistólica no teste de esforço) e 2) Baixo Risco, 65 pacientes, sem fatores de risco. A idade média foi de 37 ± 11,3 anos, sendo 63% do sexo masculino. A média da espessura de septo interventricular foi 23,9 ± 6,2 mm, da fração de ejeção 72 ± 8,1% e 26% apresentavam forma obstrutiva da doença. A MAOT foi avaliada pelo teste ergométrico com protocolo Naughton modificado, com dois fatores de atualização (FaT) 1/8 e 1/32, de forma quantitativa e qualitativa (positivo e negativo) e com três formas de análises: considerando todas as derivações do eletrocardiograma (plano periférico, frontal e ortogonal); desconsiderando os resultados do plano periférico e desconsiderando as derivações ortogonais. Resultados: A aferição da MAOT com FaT 1/8 apresentou maior sensibilidade em comparação com FaT 1/32 (FaT 1/8 MAOTméd. = 69,2 uV a 78,2 uV vs FaT 1/32 MAOTméd. = 33,2 uV a 38,7 uV, p < 0,01), resultando nas análises quantitativas de valores maiores da micro-alternância (MAOTmáx. - FaT 1/8 = 528 uV vs 124 uV = FaT 1/32, p < 0,01) e na análise qualitativa maior número de exames positivos (MAOT positiva - FaT 1/8 = 57,5% vs 19,0% = FaT 1/32). Os pacientes do grupo Alto risco apresentavam maiores valores de MAOT (Alto Risco MAOT média = 101,4 uV vs 54,3 uV Baixo Risco, p < 0,001) e 84% apresentavam exame positivo (56/67). A MAOT mostrou associação significativa com os fatores de risco para MSC: espessura septal >= 30 mm (p < 0,001), TVNS no Holter 24 h (p = 0,001), história familiar de MSC (p = 0,006) e queda da pressão arterial no esforço (p = 0,02). No rastreamento de pacientes de Alto risco, com ponto de corte de 53 uV o teste apresentou sensibilidade e especificidade de 84% e 71%, com acurácia de 0,77 (IC de 95%: 0,69 a 0,86). Conclusões: Os melhores resultados da MAOT pela metodologia Média Móvel Modificada foram encontrados analisando todas as derivações eletrocardiográficas (plano periférico, horizontal e derivações ortogonais), realizados de forma quantitativa, com Fator de Atualização 1/8 e ponto de corte para positividade 53 uV. A MAOT demonstrou associação significativa com a maioria dos fatores de risco clínicos apresentando boa acurácia no rastreamento dos pacientes de Alto Risco para MSC / Introduction: Hypertrophic cardiomyopathy (HCM) is defined as the myocardial hypertrophy in the absence of cardiac or systemic disease, being the most common genetic transmission cardiopathy and responsible for sudden cardiac death (SCD) in young adults and athletes. The first-line treatment option for prevention of SCD is the implantable cardioverter-defibrillator (ICD). Some clinical factors have been identified as high risk for the occurrence of SCD: history of cardiac resuscitation for ventricular fibrillation, episode of sustained ventricular tachycardia, family history of premature SCD, unexplained syncope, ventricular septal thickness >= 30 mm; nonsustained ventricular tachycardia (NSVT) in Holter and inadequate response of blood pressure to exercise: decrease in systolic blood pressure (SBP) > 20 mmHg or increase < 20 mmHg during effort. These criteria, however, are limited in sensitivity and specificity and new diagnostic methods have been required. The microvolt T-wave alternans (MTWA) is used as a diagnostic tool to identify high-risk patients predisposed to malignant ventricular arrhythmias and SCD. Therefore, MTWA may be helpful to indicate ICD. There are no reports in the literature concerning the use of MTWA in HCM. This research aims to evaluate the values of MTWA by modified moving average (MMA) method and the association with clinical factors for SCD. Methods: We enrolled 132 patients with HCM that were divided into two groups: 1) High Risk (HR) group, 67 patients, that had at least one risk factor for sudden cardiac death (family history of SCD; unexplained syncope; ventricular septal thickness >= 30 mm; nonsustained ventricular tachycardia; inadequate response of blood pressure to exercise) and 2) Low Risk (LR) group, 65 patients, without risk factors. The most participants were male (63%) and their mean age was 37 (± 11.3) years. All individuals were evaluated by echocardiography: 23,9 ± 6,2 mm interventricular septal thickness; 72 ± 8.1% ejection fraction and 26% left ventricular outflow gradient of more than 30 mmHg. Patients performed exercise stress testing with modified Naughton Protocol. In the present study, MTWA was assessed with the MMA method, updating factor (UF) 1/8 and 1/32, quantitative and qualitative way (positive and negative). In addition, the values of the MTWA were evaluated in three ways: all the leads of electrocardiogram; disregarding the leads of peripheral plane; disregarding the orthogonal leads. Results: The analysis of MTWA with UF 1/8 showed greater sensitivity compared with UF 1/32 (Mean MTWA, UF 1/8 = 69.2 uV to 78.2 uV vs UF 1/32 = 33.2 uV to 38.7 uV, p < 0.01). Like this, in quantitative and qualitative (positive and negative) analysis of MTWA, the values were larger in the group of UF 1/8 (UF1/8 = 528 uV vs UF 1/32 = 124 uV, p < 0.01/ Positive MTWA, UF 1/8 = 57.5% vs UF 1/32 = 19.0%, p < 0.01). The patients of High Risk group presents higher values of MTWA (HR = 101.4 uV vs LR = 54.3 uV, p < 0.001) and 84% had the positive test. The MTWA was significantly associated with risk factors for SCD: ventricular septal thickness >= 30 mm (p < 0.001), NSVT (p = 0.001), family history of SCD (p = 0.006), inadequate response of blood pressure to exercise (p = 0.02). In the analysis of high risk group, using a cutoff value of 53 uV, we observed a sensitivity of 84%, specificity of 71% and accuracy of 0.77 (95% confidence interval: 0.69 to 0.86). Conclusions: The best results of MTWA by MMA method were found by analyzing all lead ECG (frontal and peripheral plane and orthogonal leads), using UF 1/8, quantitative analysis and cut-off value 53 uV. The MTWA was significantly associated with clinical risk factors, showing a good accuracy, and can be used to effectively select high-risk patients for SCD
207

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Itamara Lucia Itagiba Neves 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.

Page generated in 0.0572 seconds