• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 408
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 421
  • 243
  • 83
  • 77
  • 63
  • 60
  • 54
  • 51
  • 49
  • 47
  • 46
  • 37
  • 36
  • 35
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Efeitos da terapia de ressincronização cardíaca no remodelamento ventricular reverso de pacientes com cardiopatia dilatada não isquêmica: avaliação pela ecocardiografia tridimensional / Effects of cardiac resynchronization therapy on left ventricular reverse remodeling in patients with non ischemic dilated myocardiopathy: evaluation by three dimensional echocardiography

Viviane Tiemi Hotta 18 June 2010 (has links)
Introdução: A terapia de ressincronização cardíaca (TRC) tem se mostrado como um tratamento eficaz no tratamento de pacientes com insuficiência cardíaca (IC) grave e distúrbio da condução ventricular. A ecocardiografia tridimensional (Eco 3D) consiste em uma nova modalidade diagnóstica com resultados promissores para a identificação da dissincronia cardíaca e avaliação dos resultados da TRC. Objetivos: Estudar os efeitos da TRC no remodelamento reverso do ventrículo esquerdo (VE), em pacientes com miocardiopatia não isquêmica, insuficiência cardíaca e distúrbio da condução intraventricular, por meio da ecocardiografia tridimensional em tempo real. Métodos: De janeiro de 2007 a junho de 2009, foram avaliados 24 pacientes com miocardiopatia dilatada não isquêmica, IC classe funcional (CF) III ou IV (NYHA), com tratamento medicamentoso otimizado, QRS > 120 ms ao eletrocardiograma, e fração de ejeção do ventrículo esquerdo (FEVE) < 0,35 submetidos à TRC. Os pacientes foram avaliados antes, três e seis meses após TRC pela CF (NYHA), qualidade de vida pelo escore de Minnesota (MLHFQ), eletrocardiograma (intervalo PR e duração do QRS), ecocardiograma bidimensional (volumes diastólico VDVE, e sistólico VSVE, do ventrículo esquerdo, fração de ejeção ventricular esquerda - FEVE), Doppler tecidual (TDI) (avaliação da dissincronia cardíaca) e análise tridimensional (VDVE, VSVE, FEVE e dissincronia pela análise do SDI systolic dyssynchrony index). Foi considerado remodelamento reverso redução > 15% do VSVE após a TRC. As diferenças das médias das variáveis contínuas foram analisadas com o teste T não pareado, entre os grupos respondedor e não respondedor, depois de satisfeita a condição de normalidade. Antes da TRC, foi realizada uma análise univariada das características clínicas, eletrocardiográficas e ecocardiográficas para a construção de um modelo de regressão logística. Resultados: 9/24(38%) dos pacientes analisados apresentaram remodelamento ventricular reverso após TRC. O grupo respondedor apresentou menores volumes ventriculares (VDVE: 230 + 35 ml vs 316 + 10 ml, p = 0,045; VSVE: 178 + 30 ml vs 238 + 10 ml, p = 0,047), avaliados pelo método de Simpson, além de maior dissincronia cardíaca, avaliada pelo Eco 3D (SDI:13 + 3% vs 9 + 3%, p = 0,005) e pelo TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). Após a análise de regressão logística, o SDI (SDI > 11%) foi o único fator independente na predição de remodelamento reverso, seis meses após a TRC (sensibilidade:0,78; especificidade:0,79). Conclusões: O Eco 3D foi eficaz na detecção do remodelamento reverso do VE após a TRC, por meio da detecção da redução dos volumes ventriculares esquerdos (VDVE, VSVE) e da melhora da FEVE. O SDI foi o único preditor independente de remodelamento reverso após a TRC. Apresentaram menor taxa de resposta seis meses após a TRC, os pacientes com maiores volumes ventriculares esquerdos e menor fração de ejeção ventricular esquerda. A TRC melhorou a CF (NYHA) de IC e a qualidade de vida pelo escore de Minnesota / Introduction: Cardiac resynchronization therapy (CRT) consists of an effective treatment for patients with severe heart failure and ventricular conduction disturbance. Three dimensional echocardiography (3D Echo) is a new diagnostic modality with promising results in the identification of cardiac dyssynchrony and for the evaluation of CRT results. Objectives: To evaluate the effects of CRT in the left ventricular (LV) reverse remodeling in patients with non ischemic dilated myocardiopathy, heart failure and intraventricular conduction disturbance by using three dimensional echocardiography. Methods: From January, 2007 to June, 2009, twenty-four consecutive patients with heart failure, sinus rhythm, QRS > 120 ms, and Functional Class III or IV (NYHA), despite optimized medical treatment and left ventricular ejection fraction (LVEF) < 0,35, underwent CRT. All patients were assessed regarding Functional Class (NYHA), and the quality of life was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). All patients were submitted to an electrocardiogram, two dimensional echocardiography (2D Echo) including the evaluation of cardiac dyssynchrony by Tissue Doppler Imaging (TDI) and 3D Echo (SDI - systolic dyssynchrony index), before, three and six months after CRT. Left ventricular reverse remodeling was defined as a reduction of at least 15% of the left ventricular systolic volume (LVSV) after CRT. The difference between the mean of the continuous variables were compared by students T test, after being tested for normality. Before CRT, it was performed a univariate analysis of clinical, electrocardiographic and echocardiographic baseline characteristics of the patients for the construction of a logistic regression model. Results: 9/24 (38%) of the patients presented with left ventricular reverse remodeling six months after CRT. Patients who presented LV reverse remodeling had smaller left ventricular volumes estimated by Simpsons rule (LV diastolic volume (LVDV): 230 + 35 ml vs 316 + 10 ml, p = 0,045; LVSV: 178 + 30 ml vs 238 + 10 ml, p = 0,047) and greater cardiac dyssynchrony detected by 3D Echo (SDI: 13 + 3% vs 9 + 3%, p = 0,005) and by TDI (138 + 31 ms vs 102 + 37 ms, p = 0,026). After logistic regression analysis, the best predictors of left ventricular reverse remodeling after CRT were the cardiac dyssynchrony indexes evaluated by TDI (twelve segments) and SDI, but SDI (SDI > 11%) was the only independent factor in the prediction of left ventricular reverse remodeling six months after CRT (sensitivity of 0,78 and specificity of 0,79). Conclusions: 3D Echo was effective in the detection of left ventricular reverse remodeling after CRT, by detecting the reduction in left ventricular volumes (LVDV, LVSV) and the increase in LVEF. SDI was the only independent predictor of LV reverse remodeling after CRT. Patients with larger LV volumes, and smaller LVEF were more prone to not respond six months after CRT. CRT improved Functional Class (NYHA) and quality of life evaluated by MLHFQ
362

Análise ecocardiográfica anatômica e funcional intraoperatória da valva mitral em pacientes com prolapso valvar submetidos à valvoplastia cirúrgica: estudo transesofágico bidimensional e tridimensional / Intraoperative anatomic and functional analyses of mitral valve in patients with valve prolapsed submitted to surgical valvuloplasty: a two-dimensional and three-dimensional transesophageal study

Mirian Magalhães Pardi 01 December 2014 (has links)
Introdução: Embora o papel da ecocardiografia transesofágica (ETE) esteja bem estabelecido na avaliação morfológica e funcional da valva mitral e na seleção dos pacientes com prolapso da valva mitral (PVM) para a cirurgia reparadora, o impacto da ETE tridimensional (3D) no resultado cirúrgico ainda não está bem demonstrado. Os objetivos deste trabalho foram avaliar o valor diagnóstico adicional da ETE 3D em comparação com a técnica bidimensional (2D) e a associação de parâmetros anatômicos tridimensionais com o resultado cirúrgico em pacientes com PVM submetidos à valvoplastia. Métodos: Para a análise comparativa da sensibilidade, especificidade e acurácia diagnóstica entre ETE 2D e 3D, foram incluídos 62 pacientes operados por PVM com insuficiência importante, sendo a inspeção cirúrgica considerada padrão-ouro. Para a análise 3D, foram estudados 54 pacientes submetidos à plástica valvar que foram divididos em 2 grupos de acordo com o grau da insuficiência mitral pós-operatória (grupo 1, insuficiência mitral ausente ou grau I; grupo 2, insuficiência mitral grau II ou III). Foram medidos pela quantificação 3D os seguintes parâmetros anatômicos: diâmetros anteroposterior e intercomissural, altura, circunferência e área do anel mitral; comprimento, área e linha de coaptação das cúspides; volume e altura do prolapso; distância dos músculos papilares à borda da cúspide; e ângulos mitroaórtico e não planar. Para a identificação de variáveis associadas aos grupos de resultados cirúrgicos, foi realizada análise univariada (teste t de Student para as variáveis contínuas e teste qui-quadrado ou o teste de Fisher para as variáveis categóricas), análise multivariada com método de regressão logística e curva ROC para a obtenção do ponto de corte. Resultados: A ETE 2D apresentou maior sensibilidade no diagnóstico de prolapso nos segmentos A2, P1 e P3 que a ETE 3D (p = 0,019, 0,023, 0,012, respectivamente) enquanto que a ETE 3D apresentou maior especificidade no segmento P1 (p = 0,006). Não houve diferença na acurácia diagnóstica ente os dois métodos. A presença de prolapso das duas cúspides (p = 0,041) e a distância do músculo papilar posteromedial à borda da cúspide (p = 0,038) foram maiores no grupo 2. Análise multivariada identificou prolapso das duas cúspides e distância do músculo papilar posteromedial à borda da cúspide maior que 30 mm como fatores associados à insuficiência mitral pós-operatória grau II ou III (p = 0,039 e 0,015, respectivamente), e com risco de 5,3 e 6,3 vezes maior de insuficiência significativa pós-operatória, respectivamente. Conclusões: A ETE 2D e 3D apresentaram acurácia equivalente no diagnóstico de PVM, com maior sensibilidade da ETE 2D no diagnóstico de prolapso nos segmentos A2, P1 e P3, e maior especificidade da ETE 3D no segmento P1. A distância do músculo papilar posteromedial à borda da cúspide obtida pela análise quantitativa 3D e a presença de prolapso das duas cúspides mostraram associação com o grau da insuficiência mitral pós-operatória grau II e III / Background: Although the transesophageal echocardiography (TEE) is well established in the morphological and functional assessment of the mitral valve and in the choice of patients with mitral valve prolapse (MVP) eligible to valvuloplasty, the impact of tridimensional (3D) TEE on surgical results has not been well demonstrated yet. The present study aimed to evaluate the additional diagnostic value of 3D TEE in comparison with bidimensional (2D) technique, as well as the correlation between 3D anatomical parameters and the surgical results in patients with MVP submitted to valvuloplasty. Methods: In order to compare the sensitivity, specificity, and accuracy between 2D and 3D TEE, 62 patients with MVP and severe mitral regurgitation were enrolled; surgical appraisal was considered as the gold-standard. Regarding 3D analysis, 54 patients submitted to valvuloplasty were divided in two groups, according to their postoperative mitral regurgitation grades (group 1, absent or grade I mitral regurgitation; and group 2, grade II or III mitral regurgitation). The following parameters were assessed quantitatively by 3D TEE: anteroposterior diameter, commissural width, height, circumference and area of the mitral ring; anterior and posterior leaflets length, leaflets surface area, coaptation length, volume and height billow; distance from the tip of the anterolateral and posteromedial papillary muscle to leaflet border; non-planar and aortic-mitral angles. Univariate analysis (Student t test for continuous variables and Chi-square or Fischer test to the categorical ones), multivariate and ROC curve analyses were performed to identify the relationship between anatomical parameters and surgical results (p < 5%). Results: 2D TEE showed higher sensitivity to diagnose MVP in A2, P1, and P3 segments, when compared with 3D TEE (p= 0.019, 0.023, and 0.012, respectively), while 3D TEE showed greater specificity to identify P1 segment (p= 0.006). No difference was observed in the accuracy between both methods. The presence of bileaflet prolapse (p= 0.041) and the distance from posteromedial papillary muscle to leaflet border (p= 0.038) were higher in group 2. Multivariate analysis showed that bileaflet prolapse and distance of more than 30 mm from posteromedial papillary muscle to leaflet border were related to grade II or III postoperative mitral regurgitation (p= 0.039 and 0.015, respectively), representing 5.3 and 6.3 more risk of significant mitral regurgitation, respectively. Conclusions: Both 2D TEE and 3D TEE presented similar accuracy in the diagnosis of MVP; 2D TEE showed higher sensitivity to diagnose the prolapse in A2, P1 and P3 segments, while the 3D TEE presented greater specificity to identify the affected P1 segment. The distance from the tip of the posteromedial papillary muscle to the leaflet border quantitatively estimated by 3D TEE and the evidence of bileaflet prolapse showed to be associated to the degree of mitral regurgitation after valvuloplasty
363

Efeito do antagonismo de angiotensina II em pacientes portadores de cardiomiopatia hipertrófica não obstrutiva / Effect of angiotensin II antagonism in patients with non-obstructive cardiomyopathy

Aloir Queiroz de Araújo Sobrinho 23 September 2005 (has links)
FUNDAMENTOS: Na cardiomiopatia hipertrófica (CMH) a disfunção diastólica do ventrículo esquerdo (VE) é causada por hipertrofia dos miócitos e fibrose intersticial. A Angiotensina II (Ang II) pode promover hipertrofia, fibrose e alteração de relaxamento miocárdico. Na hipertrofia secundária a hipertensão o bloqueio dos receptores tipo 1 (AT1) da Ang II diminui a hipertrofia e a fibrose e, em animais com CMH losartan causou reversão da fibrose miocárdica. Os efeitos do antagonismo da Ang II na CMH humana não são conhecidos. OBJETIVOS: Avaliar os efeitos do losartan, um bloqueador dos receptores AT1 da Ang II, sobre a hipertrofia e a função diastólica do VE em pacientes com CMH não obstrutiva. CASUÍSTICA E MÉTODO: Foram estudados 27 pacientes consecutivos portadores de CMH na forma não obstrutiva, com média de idade de 34,4 anos, sendo 14 homens, que receberam losartan 100 mg/dia durante 6 meses. Antes do tratamento e ao final do mesmo foram avaliadas: a classe funcional (CF), a hipertrofia e a função diastólica do VE esquerdo pela ecocardiografia (modo-M, Doppler mitral, venoso pulmonar e Doppler tecidual do anel mitral) e a concentração plasmática do fragmento amino-terminal do pro-peptídeo natriurético tipo B (NT-proBNP). Valores bi-caudais de p<0,05 em testes pareados foram considerados estatisticamente significantes. v RESULTADOS: CF - dos 19 pacientes sintomáticos antes do tratamento, 8 (42%) tornaram-se assintomáticos (p=0,008). A CF média passou de 2,04±0,81 para 1,48±0,64 (p=0,0001). Doppler ecocardiografia - redução do diâmetro atrial esquerdo de 43,3±6,2 mm para 40,5±6,1 mm (p<0,0001), diminuição da velocidade da onda atrial reversa do fluxo venoso pulmonar de 36,4±9,7 cm/s para 32,2±6,2 cm/s (p=0,008), aumento da velocidade diastólica inicial (Ea) do anel mitral de 10,7±3,2 cm/s para 11,95±3,01 cm/s (p=0,004), aumento da razão Ea/Aa de 1,11±0,36 para 1,33±0,48 (p=0,009), e diminuição da razão E/Ea de 8,37±5,4 para 6,46±3,2 (p=0,004). Não ocorreram modificações nas espessuras parietais nem nos diâmetros do VE. NT-proBNP - diminuição do valor mediano de 652 pg/ml para 349 pg/ml, assim como dos quartis e dos valores máximo e mínimo (p=0,003). CONCLUSÃO: Em pacientes com CMH não obstrutiva o antagonismo da angiotensina II com losartan 100 mg/dia durante 6 meses resultou em melhora bioquímica e da função diastólica do VE, sem evidente regressão de hipertrofia ao ecocardiograma. Esses resultados são promissores e indicam possíveis benefícios que podem ser obtidos com medicamentos que atuam inibindo o sistema renina-angiotensina em pacientes com CMH. / BACKGROUND: In hypertrophic cardiomyopathy (HCM) diastolic dysfunction of the left ventricle (LV) is caused by myocite hypertrophy and interstitial fibrosis. Angiotensin II (Ang II) has trophic and profibrotic effects on the heart, and may impair myocardial relaxation. In hypertensive LV hypertrophy Ang II type 1 (AT1) receptors blockade can reverse hypertrophy and fibrosis, and in animals with HCM, losartan reversed myocardial fibrosis. The effects of Ang II antagonism in humans with HCM are unknown. OBJECTIVES: To evaluate the effects of losartan, an AT1 blocker, in patients with non-obstructive HCM, with emphasis on LV diastolic function. PATIENTS AND METHODS: 27 consecutive patients, mean age 34.4 years, 14 males, were treated with losartan 100 mg/day during 6 months. Evaluations were performed at baseline and at 6 months, as follows: functional class (FC), left atrium diameter (LAD), LV hypertrophy and LV diastolic function (M-mode echocardiography, mitral flow and pulmonary venous flow Doppler, mitral annulus tissue Doppler), and plasma concentrations of the amino-terminal fragment of proBNP (NT-proBNP). RESULTADOS: FC - of the 19 symptomatic patients before the treatment, 8 (42%) were free of symptoms at 6 months (p=0.008). There were no changes in LV wall and cavity measures. LAD decreased from 43.3±6.2 mm to 40.5±6.1 mm (p<0.0001), and pulmonary venous atrial reverse velocity decreased from 36.4±9.7 cm/s to 32.2±6.2 cm/s (p=0.008). Tissue Doppler: mitral annulus early diastolic velocity (Ea) increased from 10.7±3.2 cm/s to 11.95±3.01 cm/s (p=0.004), Ea/Aa ratio increased from 1.11±0.36 to 1.33±0.48 (p=0.009), and E/Ea ratio decreased from 8.37±5.4 to 6.46±3.2 (p=0.004). NT-proBNP - there was a decrease in the median value from 652 pg/ml to 349 pg/ml, as well as a decrease in quartiles, maximum and minimum values (p=0.003). CONCLUSION: In patients with non-obstructive HCM, treatment with losartan 100 mg/day during 6 months resulted in Doppler echocardiographic and biochemical changes indicative of LV diastolic function amelioration, in the absence of evident LV hypertrophy regression. These preliminary results are promising and suggest that inhibition of the renin-angiotensin system may be benefic in human HCM
364

Avaliação de massas cardíacas pela ecocardiografia com perfusão em tempo real / Evaluation of cardiac masses by real time perfusion imaging echocardiography

Eliza Kaori Uenishi 11 May 2011 (has links)
Introdução: As massas cardíacas (MC) podem ser tumores, trombos ou pseudotumores. A avaliação da vascularização poderá ser uma ferramenta adicional para o seu diagnóstico diferencial. Neste estudo, demonstrou-se o valor diagnóstico da ecocardiografia com perfusão na caracterização das MC or meio de análises qualitativas e quantitativas de perfusão. Métodos: Estudo prospectivo que envolveu 107 pacientes, classificados em quatro grupos: 33 trombos, 23 tumores malignos (TM), 24 tumores benignos (TB) e 6 pseudotumores; 21 pacientes foram excluídos por não terem diagnóstico definitivo confirmado. A avaliação de perfusão foi realizada pela ecocardiografia com perfusão em tempo real, utilizando contraste à base de microbolhas. Em um grupo selecionado de pacientes (32), o estudo foi complementado com dipiridamol para avaliação da reserva de fluxo da massa. A análise foi feita qualitativa e quantitativamente por dois observadores independentes. Na análise qualitativa, os parâmetros foram: intensidade da perfusão (escore 0 a 3), velocidade do repreenchimento microvascular (escore 0 a 2), padrão de perfusão central ou periférico (escore 0 a 2) e presença de áreas de necrose (escore 0 e 1). Os dois parâmetros de quantificação das massas foram: volume de sangue microvascular (A) e fluxo microvascular regional, que é o produto da velocidade de fluxo () e volume (A). Resultados: Na análise qualitativa, o padrão mais frequente para o grupo trombos foi: sem perfusão (81,9%), sem velocidade de perfusão (81,9%) e sem área de necrose (93,4%); nos tumores, predominou perfusão discreta (62,3%), com velocidade lenta (64,2%) e áreas de necrose (30,2%). Na análise qualitativa, a variação intraobservador para escore de perfusão e de velocidade foi de 20%, para áreas de necrose de 25% e para padrão de perfusão foi de 45%. Na análise quantitativa, o grupo trombos apresentou valores de A e Ax significativamente menores quando comparados ao grupo de tumores: Trombos: A = 0,08 (0,01-0,22dB); Ax = 0,03 (0,010,14dB/s-1); TM: A = 2,78 (1,31-7,0dB); Ax = 2,0 (0,995,58dB/s-1); TB: A = 2,58 (1,24-4,55dB); Ax = 1,18 (0,453,4dB/s-1). Quando comparados apenas os grupos de tumores com o uso de dipiridamol, os TM apresentaram volume sanguíneo microvascular (A) maiores: A = 4,18 (2,14-7,93dB); Ax = 2,46 (1,424,59dB/s-1), TB: A = 2,69 (1,11-4,26dB); Ax = 1,55 (0,555,50dB/s-1). Na análise com a curva ROC, a área sob a curva = 0,95, no parâmetro volume sanguíneo microvascular (A) < 0,65dB na ecocardiografia de perfusão com e sem uso de dipiridamol foi preditor para trombo, bem como o parâmetro fluxo sanguíneo microvascular (Ax) < 0,30dB/s-1, (área sob a curva = 0,94). Para distinguir entre TM de TB, o parâmetro volume sanguíneo microvascular (A), com o uso de dipiridamol > 3,28dB foi preditor de TM (área sob a curva = 0,75). Conclusão: O estudo ecocardiográfico para avaliação da perfusão das MC mostrou que a análise qualitativa é um método diagnóstico rápido e reprodutível para diagnosticar trombos. Os tumores cardíacos apresentam volume microvascular e fluxo sanguíneo regional maior se comparados com os trombos. O uso do dipiridamol foi útil na diferenciação entre os TM e TB / Background: Cardiac masses (CM) can be tumors, thrombi or pseudotumors. Evaluation of their vascularization might be an additional tool to perform a differential diagnosis. In the present study we demonstrated the diagnostic value of perfusion echocardiography for CM characterization, by qualitative and quantitative analyses of perfusion. Methods: We prospectively studied 107 patients, who were classified into 4 groups: 33 thrombus, 23 malignant tumors (MT), 24 benign tumors (BT) and 6 pseudotumors, of which 21 were excluded because no definitive diagnosis could be confirmed. Perfusion evaluation was performed by contrast echocardiography with real time perfusion imaging using microbubbles. A group of patients (32) was selected for a complementary study using dipyridamole to evaluate mass flow reserve. Qualitative and quantitative analyses were performed by two independent observers. Parameters for qualitative analysis were perfusion intensity (0-3 score), microvascular refilling velocity (0-2 score), central or peripheral perfusion pattern (0-2 score), and presence of areas of necrosis (0 or 1 score). The two parameters for quantification of masses were microvascular blood volume (A), and regional microvascular flow which is the product of blood flow velocity and vomume (A). Results: The most frequent pattern for the thrombi group in the qualitative analysis was absence of perfusion (81.9%), followed by no perfusion velocity (81.9%), and no areas of necrosis (93.4%), whilst among tumors there was predominance of discrete perfusion (62.3%), with slowed velocity (64.2%), and areas of necrosis (30.2%). Qualitative analysis, perfusion velocity showed intraobserver variability 20%, presence of areas of necrosis of 25% and perfusion pattern of 45%. In the quantitative analysis, the thrombi group was shown to have A and Ax values significantly smaller compared to the tumor group: Thrombi: A = 0.08 (0.01-0.22dB); Ax = 0.03 (0.010.14dB/s-1); MT: A = 2.78 (1.31-7.0dB); Ax = 2.0 (0.995.58dB/s-1); BT: A = 2.58 (1.24-4.55dB); Ax = 1.18 (0.453.4dB/s-1). When only the tumor groups with the use of dipyridamole were compared, MT was shown to have greater microvascular blood volume (A): A = 4.18 (2.14-7.93dB); Ax = 2.46(1.424.59dB/s-1), BT: A = 2.69 (1.11-4.265dB); Ax = 1.55 (0.555.50dB/s-1). Analysis of the ROC curve showed that an area of 0.95 for a microvascular blood volume of A < 0.65 dB predictive curve on perfusion echocardiography, both with and without dipyridamole, predicts thrombi, and so does a <0.30dB/s-1microvascular blood flow (Ax), area under curve = 0.94. In order to distinguish MT from BT, a >3.28dB microvascular blood volume (A) using dipyridamole was predictor of MT (area under curve = 0.75). Conclusion: The echocardiographic study to evaluate CM perfusion showed that qualitative analysis is reproducible diagnostic approach for diagnosing thrombi. Cardiac tumors show greater microvascular volume and regional blood flow when compared with thrombi. Dipyridamole quantitative stress mass perfusion was useful to differentiate MT from BT
365

Visibilização de artérias coronárias epicárdicas em imagens ecocardiográficas tridimensionais com contraste de microbolhas / Visualization of the epicardial coronary arteries in microbubble contrasted tri-dimensional echocardiographic images

Danilo Meneses Lage 01 October 2010 (has links)
Com os avanços tecnológicos das últimas décadas, a ecocardiografia surgiu como uma alternativa de diagnóstico por imagem de relativo baixo custo, que não faz uso de energia ionizante ou radioativa. Recentemente, o advento dos agentes de contraste por microbolhas e dos transdutores matriciais tornou possível a visualização tridimensional da anatomia das artérias coronárias. Neste projeto, é proposta a avaliação de métodos de segmentação capazes de visibilizar as artérias coronárias epicárdicas em Imagens de ecocardiografias tridimensionais com contraste de microbolhas. Esse é o primeiro passo para o desenvolvimento de ferramentas computacionais eficazes e eficientes na assistência não invasiva ao acompanhamento do quadro clínico de pacientes, do diagnóstico ao pós-operatório. Propõe-se, uma metodologia que facilite o acesso às coronárias a partir de imagens de ecocardiografia tridimensionais com aplicação de contraste por microbolhas. Dentre as metodologias estudadas, as técnicas baseadas na teoria Fuzzy Connectedness (FC) foram identificadas como as mais promissoras. Estudou-se, portanto, seis abordagens baseadas nessa teoria, três delas são descritas na literatura (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) e três proposições originais (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). Para avaliar a acurácia desses algoritmos, confeccionou-se um conjunto de imagens simuladas, composto por 360 imagens, e selecionou-se um conjunto de imagens de exames reais, composto de 10 imagens reais de pacientes com quadro de Cardiomiopatia Hipertrópica. Para as imagens simuladas, os métodos da literatura alcançaram acurácia de 85,5% para GFC, 89,5% para RFC e 92,0% para DyWFC. Enquanto isso, os métodos propostos alcançaram acurácia de 88,9% para ASFC, 91,7 % para USkFC e 95,2% para GuFC. Para as imagens reais, os métodos convergiram para uma segmentação satisfatória quanto à usabilidade na clínica médica. Esses resultados demonstraram, ainda, o melhor desempenho do método proposto GuFC ante os demais. Dessa forma, ele se torna um candidato para ingressar na etapa de segmentação de uma ferramenta computacional para visibilização das coronárias epicárdicas no futuro / With the technological advances of recent decades, echocardiography has emerged as a relatively low cost imaging diagnostic alternative, that does not use ionizing or radioactive energy. Lately, the advent of microbubble-based contrast agents and array transducers turned possible the visualization of three-dimensional coronary arteries anatomy. The present project proposes to evaluate segmentation methods able to deal with the visualization of the epicardial coronary arteries in microbubble-based three-dimensional echocardiography images. This is the first step towards the development of effective and efficient computational tools for diagnosis and prognosis assistance of cardiac pacient. We propose a methodology to facilitate the access to epicardial coronary arteries in tridimensional echocardiographic images. Among the studied approaches, Fuzzy Connectednessbased segmentation methods were identified as being the most promising. We studied six approaches based on this theory, three of them are described in the literature (Generalized FC GFC; Relative FC RFC; Dynamic Weighted FC DyWFC) and three original contributions (Area of Search FC ASFC; Ultrasound-k FC USFC; Guided FC GuFC). To evaluate the accuracy of these algorithms, a set composed of 360 simulated images were created. We also selected a set of 10 real images, composed of hypertrophic cardiomyopathy patients. For simulated images set, the methods of literature achieved accuracy of 85.5% for GFC, 89,5% for RFC and 92,0% for DyWFC, meanwhile, the proposed method achieved accuracy of 88.9% for ASFC, 91,7 % for USkFC and 95,2% for GuFC. Using the real images set, the methods converged to good results for clinical purposes. These results demonstrate that the proposed method GuFC has shown a better performance than the others, becoming a candidate to the segmentation step in a computational tool for coronary arteries visualization in the future
366

Avaliação prospectiva do comportamento da pressão arterial, rigidez arterial e parâmetros ecocardiográficos de pacientes hipertensos com e sem a apneia obstrutiva do sono / Prospective evaluation of blood pressure behavior, arterial stiffness and echocardiographic parameters in hypertensive patients with and without obstructive sleep apnea

Fernanda Fatureto Borges 06 March 2018 (has links)
Introdução: A variabilidade de resposta pressórica e de melhora de parâmetros de lesão de órgãos-alvo frente ao ajuste do tratamento medicamentoso na Hipertensão Arterial Sistêmica (HAS) pode sofrer influências de comorbidades pouco investigadas na prática clínica. Neste contexto, estudos prévios demonstram que a apneia obstrutiva do sono (AOS), condição muito associada à HAS, está relacionada à elevação da pressão arterial (PA) e lesões de órgãos-alvo em pacientes hipertensos. No entanto, não é conhecido se durante o tratamento anti-hipertensivo, a AOS não tratada pode contribuir para um pior controle pressórico, bem como para uma menor redução da rigidez arterial e de alterações ecocardiográficas. Objetivos: Avaliar o comportamento da PA, rigidez arterial e parâmetros ecocardiográficos em pacientes hipertensos com e sem AOS em tratamento medicamentoso para PA ao longo de 18 meses. Métodos: Recrutamos pacientes hipertensos que foram submetidos ao uso padronizado de hidroclorotiazida 25mg e enalapril 20mg 2x ao dia (ou losartan 50mg 2x ao dia) por 30 dias. Após avaliação clínica, monitorização ambulatorial da pressão arterial (MAPA), polissonografia noturna, medida da rigidez arterial pela velocidade de onda de pulso (VOP) carótida-femoral e ecocardiograma transtorácico, os pacientes foram seguidos com um protocolo padronizado de adição de anti-hipertensivos, visando o controle da PA. A AOS foi definida por um índice de apneia e hipopneia >=15 eventos/hora de sono. Foram realizadas reavaliações da MAPA, do ecocardiograma e da VOP aos 6 meses e 18 meses de seguimento. O tratamento foi orientado sem o conhecimento da presença ou não da AOS. Usamos equações de estimação generalizada para comparação dos grupos e dos tempos de avaliação de forma não ajustada e, posteriormente, com ajuste para fatores de confusão tais como sexo, idade, índice de massa corpórea, diabetes, estimativa de taxa de filtração glomerular e número de medicamentos anti-hipertensivos. Resultados: Após recrutarmos inicialmente 125 pacientes, 94 foram analisados (idade média: 55±9 anos). A frequência da AOS foi de 55% (52 pacientes). Comparados aos pacientes sem AOS, pacientes com AOS tinham um predomínio do sexo masculino (31% vs. 53,8%; p=0,026) e maior circunferência cervical (37,7±4 vs. 40,4±3,7cm; p=0,001), respectivamente. Não observamos diferenças nas medidas de PA sistólica (127±17 vs. 133±16mmHg; p=0,259), diastólica (80±11 vs. 81±12 mmHg; p=0,590) e média (96±13 vs. 99±13mmHg; p=0,542) entre os grupos sem AOS e com AOS após 30 dias da medicação padronizada descrita acima (período basal). Comparado ao período basal, não observamos diferenças significativas na redução da PA sistólica e diastólica de 24hs e da vigília aos 6 meses e 18 meses entre os grupos com e sem AOS. A PA sistólica durante o sono também não teve diferenças significantes, mas a PA diastólica no sono foi reduzida de forma mais pronunciada no grupo com AOS do que sem AOS (6 meses: -4,9±11,8 vs. -0,3±10,3mmHg; e 18 meses: -6,7±11,1 vs. - 1,2±10,6mmHg; p=0,027), respectivamente. Após ajustes, encontramos uma forte tendência de maior redução da PA diastólica durante o sono no grupo com AOS (p=0,057). A taxa de controle da PA nas 24hs ( < 130x80mmHg) foi semelhante entre os grupos com e sem AOS (basal: 42,3 vs. 45,2%; 6 meses: 46,9 vs. 57,5%; 18 meses: 66,7 vs. 61,5%), respectivamente. Não houve diferença na evolução na quantidade e classes de medicações anti-hipertensivas usadas no seguimento. O índice de massa corpórea teve um discreto aumento no seguimento, mas sem diferença entre os grupos. Com relação à rigidez arterial, o grupo com AOS apresentou VOP maior comparado aos pacientes sem AOS na avaliação basal (10,3±1,9 vs. 9,2±1,7 m/s; p=0,024). Evolutivamente, ambos os grupos apresentaram redução semelhante da VOP ao longo do seguimento. Não encontramos diferenças entre os grupos na análise basal e evolutiva do ecocardiograma transtorácico após ajustes. Conclusão: O tratamento antihipertensivo combinado promoveu uma resposta similar na redução da PA de 24hs, na melhora da rigidez arterial e na evolução de parâmetros ecocardiográficos em pacientes hipertensos com e sem AOS / Introduction: The blood pressure (BP) response and improvement of target organ damage parameters are variable in response to drug therapy of hypertension (HTN) and may be influenced by comorbidities frequently underdiagnosed in clinical practice. In this context, previous studies show that obstructive sleep apnea (OSA) is very common in HTN and associated with elevated BP and target organ damage in hypertensive patients. However, it is unknown whether untreated OSA may contribute to impair BP control, as well as to a lower reduction of arterial stiffness and echocardiographic parameters during antihypertensive treatment. Objectives: To evaluate BP behavior, arterial stiffness and echocardiographic parameters in response to blood pressure treatment during 18 months in hypertensive patients with and without obstructive sleep apnea. Methods: We recruited hypertensive patients who underwent standardized use of hydrochlorothiazide 25mg daily and enalapril 20mg twice a day (or 50mg losartan twice a day) for 30 days. After clinical evaluation, ambulatory BP monitoring (ABPM), nocturnal polysomnography, arterial stiffness measurement by carotid-femoral pulse wave velocity (PWV) and transthoracic echocardiogram, all patients were followed up using a standardized protocol adding anti-hypertensives aiming BP control. OSA was defined by an apneahypopnea index >= 15 events/hour of sleep. The ABPM, echocardiogram and PWV were reassessed at 6 months and 18 months of follow-up. Physicians responsible for BP treatment did not have access to sleep data. We used generalized estimation equations to compare the groups and the evaluation times in an unadjusted manner and further adjusted for confounding variables such as gender, age, body mass index, diabetes, estimated glomerular filtration rate and number of antihypertensive drugs. Results: After initially recruiting 125 patients, 94 were analyzed (mean age: 55±9 years). The frequency of OSA was 55% (52 patients). Compared to patients without OSA, patients with OSA had a predominance of males (31% vs. 53.8%, p=0.026) and larger cervical circumference (37.7±4 vs. 40.4±3.7cm; p=0.001), respectively. We did not observe differences in the 24hs systolic (127±17 vs. 133±16mmHg, p = 0.259), diastolic (80±11 vs. 81 ±12 mmHg, p=0.590) and mean BP (96±13 vs. 99±13mmHg; p=0.542) between groups after 30 days of the standardized medication described above (baseline period). Compared to baseline, we did not observe significant differences in the reduction of 24hs, daytime systolic and diastolic BP at 6 months and 18 months between OSA and no OSA groups. The nighttime systolic BP also did not have significant differences, but the nighttime diastolic BP decreased significantly in the OSA group compared to no OSA group (6 months: -4.9±11.8 vs. -0.3±10.3mmHg; 18 months: -6.7±11.1 vs. - 1.2±10.6mmHg; p=0.027), respectively. After adjustments, we found a strong tendency for a greater reduction of nighttime diastolic BP in the OSA group (p=0.057). The BP control rate at 24 hours ( < 130x80mmHg) was similar between the groups with and without OSA (baseline: 42.3 vs. 45.2%; 6 months: 46.9 vs. 57.5%; 18 months: 66.7 vs. 61.5%), respectively. There was no difference in the amount and classes of antihypertensive medications prescribed during the follow-up. Body mass index had a slight increase in the follow-up, but similar in both groups. Regarding arterial stiffness, patients with OSA had higher PWV compared to patients without OSA at baseline (10.3±1.9 vs. 9.2±1.7m/s; p=0.024). However, both groups presented similar PWV reductions in the follow-up. We did not find differences between the groups in the basal and follow-up echocardiogram analysis after adjustments. Conclusions: Combined antihypertensive treatment aiming BP control promoted similar 24-hour BP reduction, arterial stiffness improvement and echocardiographic parameters evolution in hypertensive patients with and without OSA
367

Impacto do uso rápido dos betabloqueadores sobre a mortalidade e remodelamento ventricular na insuficiência cardíaca avançada / Impact of rapid beta-blockers therapy on mortality and ventricular remodeling in advanced heart failure

Domingos Sávio Barbosa de Melo 25 March 2011 (has links)
Fundamento: A terapia com betabloqueadores é fundamental para o tratamento da insuficiência cardíaca congestiva. Entretanto, apesar dos dados que documentam os benefícios dos betabloqueadores, a otimização da dose desses medicamentos durante a hospitalização ainda não foi testada. Objetivos: Avaliar a segurança da efetividade do betabloqueio rápido em pacientes hospitalizados por Insuficiência Cardíaca avançada. Métodos: Em estudo clínico randomizado, foram incluídos 92 pacientes com insuficiência cardíaca e fração de ejeção do ventrículo esquerdo <45%: 46 no grupo tratamento e 46 no grupo controle. Do total 59 (64,1%) pacientes eram do sexo masculino, com idade média de 62,25±14,43 anos. Durante o período de internação esses pacientes foram alocados aleatoriamente para receber incrementos da dose de betabloqueadores de forma rápida, a cada dois dias (grupo tratamento), ou a cada 15 dias (grupo controle). O desfecho principal foi a ocorrência de reinternação ou morte por causas diferentes. Foram considerados como efeitos adversos hipotensão arterial, bradicardia e piora da insuficiência cardíaca. Resultados: A fração de ejeção média do ventrículo esquerdo foi de 27,24±9,08, o diâmetro diastólico final médio 66,15±8,65 e o diâmetro sistólico final médio 57,04±9,96. No grupo tratamento, houve redução significativa do DSFVE em três meses e um ano (p<0,001), enquanto no grupo controle permaneceu inalterado (p=0,337). O DDFVE apresentou redução significativa (p=0,036) no grupo tratamento que não foi significativa no grupo controle (p=0,250). Houve aumento significativo da FEVE no grupo tratamento (p<0,001) em três meses, o que não ocorreu no grupo controle (p=0,151), mas não houve diferença entre os grupos em um ano. A distância percorrida no teste de caminhada de 6min aumentou significativamente (p<0,001) no grupo tratamento em relação ao grupo controle. O grupo tratamento apresentou probabilidade livre de internação significativamente maior que a do grupo controle (p=0,045). Com referência à sobrevida, o grupo tratamento apresentou níveis significativamente maiores que a do grupo controle no período avaliado (p=0,002). Conclusões: O incremento rápido da dose de betabloqueador durante a internação por descompensação de insuficiência cardíaca foi segura e melhorou a sobrevida, o remodelamento ventricular e a capacidade de fazer exercícios / Background: The beta-blocker therapy is essential in congestive heart failure treatment. However, despite data documenting, the benefits of beta-blockers, and the optimization of these medications dosage during hospitalization has not been tested. Objectives: To evaluate the safety of the efficiency of acute beta-blockade on hospitalized patients due to advanced heart failure. Methods: In a randomized clinical trial, 92 patients with heart failure and ejection fraction of left ventricle <45% were included: 46 in the treatment group and 46 in the control group. In the assessed group 59 (64.1%) patients were male, with mean age of 62.25 ± 14.43 years. During the hospitalization period and those who were randomized to acute beta-blocker dose increments, every other day (treatment group) or every 15 days (control group) were selected. The main outcome was the occurrence of rehospitalization or death for different causes. Hypotension, bradycardia, and worsening heart failure were considered as adverse effects. Results: The mean ejection fraction of left ventricle was 27.24±9.08, the average end-diastolic diameter 66.15±8.65 and the average end-systolic diameter 57.04±9.96. In the treatment group, significant reduction of DSFVE in three months and one year (p<0.001) has been observed, whereas in the control group remained unchanged (p=0.337). The LVEDD decreased significantly (p=0.036) in the treatment group and in the control group it was not significant (p=0.250). There was a significant increase of the LVEF in the treatment group (p<0.001) in three months, and no difference occurred in the control group (p=0.151), and no difference between groups in a year was observed. During the 6 min walking test the treatment group showed a significant distance increase (p<0.001) when compared with the control group. The treatment group had free admission probability significantly higher than the control group (p=0.045). As to patients survival, the treatment group showed significantly higher levels than the control group during the evaluation period (p=0.002). Conclusions: Fast increase of the beta-blockers dosage during hospitalization in decompensated heart failure was safe and improved survival, ventricular remodeling, and exercise capacity
368

Medida do strain bidimensional do ventrículo esquerdo pré-implante percutâneo de endoprótese valvar aórtica: correlação com a evolução após o procedimento / Measurement of bidimensional strain of left ventricle before percutaneous implantation of aortic valve endoprosthesis: correlation with evolution after the procedure

Lucas Arraes de França 24 May 2017 (has links)
INTRODUÇÃO: O implante transcateter de prótese valvar aórtica (TAVI) surge nos dias atuais como uma opção terapêutica para os pacientes sintomáticos portadores de estenose aórtica grave. Cerca de 200 mil pacientes em todo o mundo já foram submetidos ao TAVI. Não há grandes estudos que tenham avaliado a correlação prognóstica entre parâmetros ecocardiográficos antes do TAVI e eventos cardiovasculares a longo prazo. É relevante analisar se o strain pré-procedimento e outros parâmetros se comportam como fatores preditores independentes de eventos após o procedimento. MÉTODOS: Foram avaliados, de novembro de 2009 a outubro de 2016, 86 pacientes, submetidos a avaliação ecocardiográfica antes do TAVI e 30 dias após o procedimento, com análise do strain do ventrículo esquerdo pelo speckle tracking bidimensional e outros parâmetros ecocardiográficos. Esses pacientes foram acompanhados clinicamente e avaliados quanto aos desfechos: mortalidade global, mortalidade cardiovascular, classe funcional de insuficiência cardíaca e necessidade de reinternação cardiovascular. RESULTADOS: O strain global longitudinal pré-TAVI reduzido (valor absoluto) aumentou a chance de reinternação cardiovascular (OR: 0,87; 0,77 ±0,99; P= 0,038). A redução da relação E/e´ em 30 dias após o TAVI associou-se à queda da mortalidade global (OR: 0,97; 0,95 ±0,99; P = 0,006), bem como valores elevados pré procedimento dessa relação se associaram a maiores taxas de insuficiência cardíaca classe funcional III ou IV da New York Heart Association após a intervenção (OR: 1,08; 1±1,18; P = 0,049). CONCLUSÃO: Os resultados deste trabalho indicam que o strain global longitudinal pré-procedimento demonstrou ser um preditor de reinternação cardiovascular pós-intervenção a longo prazo. A relação E/e´ pré-procedimento apresentou correlação diretamente proporcional com o desenvolvimento de insuficiência cardíaca classe funcional III ou IV a longo prazo, assim como sua queda acentuada 30 dias após o procedimento correlacionou-se com menor mortalidade global. / INTRODUCTION: Transcatheter aortic valve replacement (TAVR) is a therapeutic option for symptomatic patients with severe aortic stenosis. Approximately 200,000 patients around the world have already undergone TAVR. No large studies have evaluated prognostic correlation between echocardiographic parameters before TAVR and long-term cardiovascular events. It is relevant to analyze strain before procedure and how other parameters work as independent predictors of events after the procedure. METHODS: A total of 86 patients were evaluated from November 2009 to October 2016. They underwent echocardiographic evaluation before TAVR and 30 days after the procedure with analysis of strain of the left ventricle by bidimensional speckle tracking and other echocardiographic parameters. Patients were followed clinically and evaluated in relation to outcomes: global mortality, cardiovascular mortality, functional class of heart failure and need for cardiovascular readmissions. RESULTS: Global longitudinal strain before reduced TAVR (absolute value) increased the chance of cardiovascular readmission (odds ratio: 0.87; 0.77 ± 0.99; p = 0.038). Reduction of E/e´ relationship 30 days after TAVI was associated with a drop in global mortality (odds ratio: 0.97; 0.95 ± 0.99; p = 0.006). In addition, high values for this relation before the procedure were associated with higher rates of New York Heart Association functional class III or IV heart failure after the intervention (odds ratio: 1.08; 1.00 ± 1.18; p = 0.049). CONCLUSIONS: Results of this study indicate that global longitudinal strain before the procedure is a predictor of cardiovascular readmission after TAVR. The E/e´relationship before the procedure presented a correlation directly proportional to the development of long-term functional class III or IV heart failure as well as its accentuated drop 30 days after the procedure was correlated with lower global mortality.
369

Identificação de lesões coronárias graves por meio do strain bidimensional longitudinal do ventrículo esquerdo na síndrome coronariana aguda sem elevação do segmento ST / Severe coronary artery stenosis identification by two dimensional strain in non-ST- elevation acute coronary syndrome

Andréa de Andrade Vilela 20 October 2014 (has links)
Estimativas nacionais e internacionais indicam que a síndrome coronariana aguda é uma das principais causas de internação hospitalar e óbito. A maioria desses pacientes tem diagnóstico de síndrome coronariana aguda sem supradesnivelamento do segmento ST (SCASSSST) e possui amplo espectro de gravidade, que varia de acordo com características clínicas e laboratoriais. A estratificação de risco é essencial para auxiliar na decisão clínica, discriminando quais pacientes se beneficiam de estratégias mais agressivas. Os escores TIMI e GRACE são os mais utilizados e com valor prognóstico estabelecido por estudos de coorte prospectiva. O strain longitudinal bidimensional (S2DL) permite a quantificação da deformidade miocárdica por meio do rastreamento de \"marcas acústicas\" naturais do músculo cardíaco pelo ultrassom, apresentando valores reduzidos na presença de isquemia miocárdica. O objetivo principal desse trabalho foi identificar, por meio do S2DL do ventrículo esquerdo, quais pacientes com SCASSSST apresentam estenose coronariana maior ou igual a 70%. Os objetivos secundários foram: 1) Identificar a porcentagem de pacientes categorizados como de baixo risco e moderado risco, segundo os escores TIMI e GRACE, que apresentaram estenose coronária maior ou igual a 70%; 2) Determinar um valor de corte do S2DL e número mínimo de segmentos adjacentes acometidos que se correlacionem com o território irrigado pela coronária comprometida (com estenose maior ou igual a 70%) nos pacientes portadores de SCASSSST. Total de 100 pacientes com Idade de 60±11,4, 62% do sexo masculino e predomínio de pacientes (p) de baixo e moderado risco cardiovascular (80% pelo escore TIMI e 99% pelo escore GRACE). Divididos em grupo A (34p) com estenose coronária < 70% e grupo B (66p) com estenose coronária >=70%. Os escores clínicos foram maiores no grupo B (TIMI 3,59±1,4; p=0,008 e GRACE 88,7±24,18; p=0,040). O strain longitudinal global (SLG) permitiu identificar os pacientes com estenose coronária >=70% (AUC=0,72, sensibilidade=50%, especificidade=90%, valor preditivo positivo= 75,1% e valor preditivo negativo=74,9%). No grupo B, 72,8% e 98,5% foram categorizados como de baixo e moderado risco pelos escores TIMI e GRACE, respectivamente. O strain longitudinal segmentar (SLS) permitiu identificar a coronária culpada pelo evento isquêmico, com valor de cut-off e número mínimo de segmentos estimados em: -14 e 4 segmentos para coronária descendente anterior, -16 e 3 segmentos para a coronária circunflexa e coronária direita. Concluímos que o SLG mostrou ser acurado em discriminar pacientes com estenose coronária grave, mesmo naqueles com escore de risco baixo e moderado pelos escores TIMI e GRACE. O SLS permite estimar a área de miocárdio isquêmico por meio do número de segmentos com deformidade alterada, e conhecer a coronária culpada mais provável. / National and international estimates indicate that acute coronary syndrome is one of the major causes of hospitalization and death. Most of these patients have a diagnosis of non-ST-elevation acute coronary syndrome (NSTE-ACS) and have wide spectrum of severity. Risk stratification is essential to assist in clinical decision. The TIMI and GRACE risk scores are the most used and the prognostic values were established by prospective cohort study. Myocardial strain by speckle tracking is a technique based on widely available two-dimensional grayscale echocardiography, enabling the accurate evaluation of global and regional myocardial function, and it is has been shown to be sensitive to abnormalities caused by ischemia. The main objective of this study was to identify, through global longitudinal strain, whose patients (p) with NSTE-ACS had >= 70 % coronary stenosis. The secondary objectives were: 1) Identify the percentage of p categorized as low or moderate risk according to the TIMI and GRACE risk scores , who showed coronary stenosis >= 70 % ; 2) Determine a cutoff value of regional strain and the minimum number of segments allowing the identification of the culprit coronary artery in p with NSTE-ACS. Hundred (p) with diagnosis NSTE-ACS were stratified according to TIMI and GRACE risk scores, and all p underwent coronary angiography. Global longitudinal strain (GLS) and territorial strain (TS) were calculated. Age 60 ± 11.4, 62% male. Majority were low and moderate cardiovascular risk (TIMI score by 80 % and 99 % by the GRACE score). They were divided into group A (34p) with coronary stenosis < 70 % and group B (66p) with coronary stenosis >= 70 %. Clinical scores were higher in group B (TIMI 3.59 ± 1.4, p = 0.008 and 88.7 ± GRACE 24.18, p = 0.040). SLG was accurate identifying p with coronary stenosis >= 70 % (AUC = 0.72, p=0.001, sensitivity = 50 %, specificity = 90 %, positive predictive value = 75.1 % and negative predictive value = 74.9 %). Group B were low and moderate cardiovascular risk 72.8 % by TIMI risk score and 98.5 % by GRACE risk scores. TS was able to identify the culprit coronary in an ischemic event with cutoff values and minimum number of damaged segments as follow: -14 and 4 segments for anterior descending coronary, -16 and 3 segments to the circumflex coronary and right coronary. SLG has proved accurate in discriminating patients with severe coronary stenosis, even in those with low and moderate risk by TIMI and GRACE risk scores. TS estimates the area of ischemic myocardium by the number of segments with abnormal deformity, and suggests the most likely culprit coronary.
370

Ecocardiografia fetal no primeiro trimestre da gestação / First trimester fetal echocardiography

Sandra Regina Marques Carvalho 15 December 2006 (has links)
Os objetivos deste estudo foram determinar o índice sucesso na realização de um ecocardiograma fetal completo entre a 11ª e a 14ª semanas, estabelecer a semana mais adequada para a realização de um exame completo, mensurar os diâmetros dos anéis das valvas cardíacas e comparar os diâmetros obtidos com o comprimento crânio-nádegas (CCN) correlacionando a evolução das dimensões cardíacas com o crescimento fetal nesta fase evolutiva. Avaliamos por ecocardiografia 46 fetos que apresentavam translucência nucal e avaliação Doppler do fluxo do ducto venoso normais. O estudo ecocardiográfico fetal foi realizado por via transvaginal, entre a 11ª e a 14ª semanas, com intervalos seriados de uma semana. Em cada exame, foram obtidos os três principais planos ecocardiográficos básicos e os diâmetros das valvas aórtica, pulmonar, mitral e tricúspide. As medidas dos diâmetros valvares foram comparadas ao diâmetro do CCN. Os resultados demonstraram uma taxa de sucesso na obtenção de um ecocardiograma completo de 37% na 11ª semana, de 85% na 12ª semana e de 100% entre a 13ª e a 14ª semanas. O corte mais freqüentemente obtido, nas duas primeiras semanas, foi o eixo longo e o mais difícil de ser visibilizado foi o eixo curto. As curvas de crescimento dos diâmetros das valvas mitral, tricúspide, aórtica e pulmonar demonstraram uma correlação linear com o crescimento fetal com valores de r² de 0,74, 0,75, 0,77 e 0,73. Não houve diferença estatisticamente significativa entre os diâmetros das valvas atrioventriculares e entre os diâmetros das valvas ventriculoarteriais. A obtenção dos três planos ecocardiográficos básicos em 85% dos casos na 12ª semana e 100% dos casos, a partir da 13ª semana, demonstra que é possível a realização de um ecocardiograma fetal completo no primeiro trimeste da gestação, por via transvaginal. Houve correlação positiva entre os diâmetros valvares e o CCN demonstrando uma curva de crescimento neste período. A comparação entre diâmetros valvares mitral e tricúspide, do mesmo modo que, a comparação entre os diâmetros valvares aórtico e pulmonar não apresentaram diferenças estatisticamente significativas, sugerindo não haver dominância no tamanho destas estruturas, nesta fase do desenvolvimento em fetos normais. / The aim of this study was to assess the feasibility of performing a complete echocardiography study during the first trimester of pregnancy by transvaginal approach and to establish the best week to accomplish a complete evaluation. A correlation between the measurements of the diameters of the cardiac valves and the gestational age along this period of the fetal life was made. Forty-six fetuses with normal nuchal translucency and Doppler evaluation of the venous duct were submitted to fetal echocardiography studies by transvaginal approach between the 11 and 14 weeks of gestation with a week interval. The following measurements were obtained: mitral, tricuspid, aortic and pulmonary valves diameters and the crown-rump length (CRL). The obtained results of the cardiac dimensions were compared with the CRL in the four weeks determinations. The rates of complete echocardiography evaluation were 37%, 85% and 100% at 11, 12 and 13 – 14 weeks, respectively. The longitudinal view was the easiest to obtain (100% at 12 weeks) and the short view was the most difficult one. There was no statistically significant difference between neither the diameters of the mitral and tricuspid nor the aortic and pulmonary valves. The diameters of the valves were correlated with the CRL and a linear growing curve was obtained with values of r2 of 0.74, 0.75, 0.77 and 0.73 respectively. The study demonstrated the feasibility of a complete fetal echocardiography evaluation by transvaginal approach during the first trimester of gestation. The rate of a complete evaluation increased along the period and reached 100% at 13 weeks. The longitudinal view was the easiest to obtain with a success rate of 100% at 12 week. There was a linear correlation between de cardiac valves diameters and the cranial caudal measurement revealing a relationship between the cardiac and fetal development during this phase of fetal life. The absence of statistically significant difference between the left and right valves dimensions possibly means that there is no predominance of right or left chambers during this period of evaluation.

Page generated in 0.0403 seconds