• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 13
  • 1
  • 1
  • 1
  • Tagged with
  • 37
  • 37
  • 37
  • 21
  • 21
  • 21
  • 19
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

"Fisioterapia na cicatrização e recuperação funcional nos portadores de úlcera de hipertensão venosa crônica: uso da estimulação elétrica com corrente de alta voltagem" / Physical therapy in cicatrization and functional recovery of chronic venous hypertension ulcer bearers : the use of electrical stimulation by means of high voltage current

Eliane Jeronimo Pires 15 September 2005 (has links)
O objetivo deste trabalho foi avaliar os efeitos da estimulação elétrica com corrente de alta voltagem na cicatrização da úlcera de hipertensão venosa crônica, bem como na dor referida, em 13 pacientes portadores de 20 úlceras. Os pacientes diferiram quanto à variação da área da ferida ao longo do tratamento. As curvas individuais indicaram a eficácia do estudo. Dos 13 pacientes que participaram do estudo, observamos que em quatro as feridas cicatrizaram totalmente, enquanto em seis elas reduziram o seu tamanho e em três, aumentaram. Não foram observados efeitos adversos causados pela eletroestimulação. A dor apresentou melhora significativa ou cessação em todos os pacientes / The objectives of this study was to evaluate high voltage electric stimulation effects over chronic venous hypertension ulcer, as well over the referred pain, in 13 patients bearing 20 ulcers. The patients have differed among themselves in relation to the ulcer area throughout the study. The individuals curves indicated the treatment efficacy. It was observed that the ulcer area have been healed in four patients, reduced in six and increased in three of the thirteen patients who has participated in this study. It was not observed adverse effects due to electrical stimulation. The pain has showed meaningful advance or ceasing in all patients
22

Efeitos da neuroestimulação domiciliar associada ao treino motor em pacientes com acidente vascular cerebral na fase crônica / Effects of home-based neurostimulation associated with motor training in chronic stroke patients

Renata Laurenti dos Santos 30 April 2010 (has links)
A estimulação somatossensitiva através da estimulação repetitiva de nervos da mão parética é uma abordagem promissora na recuperação motora do membro superior de pacientes com acidente vascular cerebral (AVC) na fase crônica e habitualmente é realizada em ambiente hospitalar. A dificuldade de comparecimento frequente de pacientes com AVC ao hospital pode prejudicar a implementação desta estratégia terapêutica em nosso meio. A reabilitação domiciliar pode ser uma alternativa interessante, além de ser menos dispendiosa do que a reabilitação hospitalar. O atual estudo teve como objetivo principal verificar a melhora em desempenho na função do membro superior parético após uma intervenção de estimulação somatossensitiva associada a treino motor, em ambiente domiciliar. Foi realizado um ensaio clínico aleatorizado, com mascaramento duplo e dois tipos de intervenção: ativa ou controle. Os pacientes do grupo ativo foram instruídos a utilizar um dispositivo de estimulação elétrica do nervo mediano, por duas horas. Os pacientes do grupo controle também foram instruídos a usar o dispositivo durante duas horas, porém sem que houvesse estimulação do nervo. Imediatamente após a utilização do dispositivo, todos os pacientes foram orientados a realizar um treino motor baseado no teste de Jebsen-Taylor. O tratamento foi realizado diariamente, ao longo de um mês. O desfecho primário foi o efeito da estimulação somatossensitiva (ativa versus controle) associada a treino motor sobre a melhora da função do membro superior parético avaliada pelo teste de Jebsen-Taylor. Os desfechos secundários foram: 1) melhora na independência funcional, avaliada pela Medida de Independência Funcional (MIF); 2) aderência às intervenções propostas, avaliada através de registros em uma agenda, e de relatos orais dos pacientes; 3) eventos adversos decorrentes dessas intervenções. O desempenho no teste de Jebsen-Taylor e na Medida de Independência Funcional (MIF) foi avaliado antes das intervenções (D0), ao seu término (D30) e quatro meses após o seu término (D150). Para a comparação da melhora em desempenho no teste de Jebsen-Taylor e da melhora em pontuação na MIF no grupo ativo e no grupo controle, foi utilizada análise de variância com medidas repetidas (ANOVAMR) com fatores grupo (ativo e controle) e tempo (D30 e D150). Foi observado um efeito significativo de grupo (F=5,02; p=0,038) na ausência de efeitos significativos de tempo ou interação grupo*tempo (p>0,05) em relação à melhora em desempenho no teste de Jebsen-Taylor. Não houve diferenças estatisticamente significantes entre os grupos em relação à pontuação na MIF após o tratamento. O grupo ativo apresentou maior aderência ao tratamento do que o grupo controle, porém esta conclusão foi baseada em informações fornecidas pelos pacientes, sem observação direta da pesquisadora. Não observamos eventos adversos relevantes. Este estudo é pioneiro por demonstrar efeitos benéficos, em longo prazo, da estimulação somatossensitiva associada a treino motor realizado em ambiente domiciliar, sem a supervisão de um terapeuta. Para a realização de estudos futuros, sugerimos algumas modificações em relação ao protocolo de estimulação somatossensitiva e treino motor, assim como combinações da técnica utilizada a outras técnicas de neuroestimulação / Somatosensory stimulation in the form of peripheral nerve stimulation is a promising strategy to improve motor function of the upper limb in chronic stroke patients and is usually administered in research laboratories. The usual difficulty in commutting to and from the hospital in a regular basis at short intervals of time is an obstacle for implementation of this therapeutic approach in our country. Home-based rehabilitation may be an interesting alternative, in addition to being less expensive than hospital-based rehabilitation. The current study aims to evaluate the improvement in performance of the paretic upper extremity after an experimental intervention consisting of somatosensory stimulation associated with motor training, performed at home. This study is a randomized, double-blind clinical trial, with two different types of interventions: active or control. Patients in the active group were instructed to use a device of electrical stimulation of the median nerve, for two hours. Patients in the control group were also instructed to use the device for two hours, and sham stimulation was administered. Immediately after the use of the device, all patients were instructed to train tasks that are part of the Jebsen-Taylor test. Treatment was performed daily, for one month. The primary outcome was improvement in performance of the paretic hand, evaluated by the Jebsen-Taylor test. Secondary outcomes were: 1) improvement in the Functional Independence Measure (FIM); 2) compliance with the proposed interventions, assessed through a daily written log, and oral reports of the patients; 3) possible adverse events from these interventions. Performance in the Jebsen-Taylor test and FIM scores were assessed before the interventions (D0), immediately after its end (D30) and four months after its end (D150). Analysis was performed with repeated- measures ANOVA (ANOVARM) with factors GROUP (active and control) and TIME (D30 and D150). Regarding Jebsen-Taylor test improvement, there was a significant effect of GROUP (F=5.02; p=0.038) in the absence of significant effects of TIME or interaction GROUP*TIME (p>0.05). There were no significant differences in FIM scores in either group after treatment. Compliance with treatment was greater in the active than in the control group, but conclusions about this finding are limited because data were collected solely based on information provided by patients. No relevant adverse events were observed. This study pioneered home-based somatosensory stimulation combined with motor training, without direct supervision of a therapist. We suggest changes to be made in the protocol in future studies, as well as investigation of effects of somatosensory stimulation combined with other neurostimulation techniques
23

Avaliação clínico-experimental dos efeitos da estimulação neuronal na resposta funcional, na neuroproteção e na neuroplasticidade após isquemia cerebral. Estudo da FES em pacientes portadores de sequela de AVE em modelo experimental em ratos / The motor recovery and cortical plasticity after stroke induced by functional electrical stimulation therapy

Rebeca Boltes Cecatto 10 May 2011 (has links)
INTRODUCÃO: O Acidente Vascular Encefálico (AVE) é uma das principais causas mundiais de morte e incapacidade crônica de acordo com a Organização Mundial da Saúde (OMS). Os mecanismos neuronais envolvidos na aquisição de funcionalidade e independência aapós o AVE estão em discussão na literatura e compreendem provavelmente a reativação do tecido neuronal da zona de penumbra, a resolução da diásquise, a reparação tecidual das áreas acometidas, e provavelmente mecanismos plásticos neuronais do tecido preservado adjacente à lesão. A estimulação elétrica funcional (FES) é utilizada com sucesso desde os anos 1960 para a estimulação e aquisição de funcionalidade após as lesões motoras corticais encontradas no AVE. A despeito disso, pouco se sabe sobre a influência da FES na neuroplasticidade e no neurotrofismo das áreas envolvidas com o controle motor. OBJETIVOS: Este estudo tem por objetivo avaliar a melhora funcional e mudanças na neuroplasticidade cortical de ratos submetidos à isquemia cerebral, tratados com um modelo experimental da FES. MÉTODOS: Analisamos um grupo de 8 ratos portadores de hemiparesia esquerda após isquemia encefálica cortical frontoparietal direita da área sensitivomotora das patas anterior e posterior, divididos em 2 grupos: A) sem uso de qualquer terapia após a lesão; e B) submetidos a um período de 14 dias de estimulação neuromotora com o uso de um modelo experimental da FES. Para a avaliação clínico-funcional foram realizados a Análise do Comportamento Motor Espontâneo pelo Infrared, e o Foot Fault Test nos momentos prévios a lesão, posterior a lesão antes da estimulação e posterior a 14 dias de estimulação com a FES. As respostas plásticas nesses animais foram analisadas através de imunorreatividades com o MAP-2 e o NF 200 nas regiões corticais e de corpo caloso. Todos os dados foram sumetidos à análise estatística. RESULTADOS: Foram encontradas diferenças estatísticas nos parâmetros funcionais do Foot Faul Test, na Análise do Comportamento com o Infrared e na imunomarcação da MAP-2 nas comparações dos grupos ESTIMULADO e NÃO ESTIMULADO, sendo que o grupo estimulado apresentou maior grau de recuperação motora que o grupo não estimulado. A análise da imunomarcação da MAP-2 demonstrou aumento na área imunomarcada no hemisfério lesado do grupo estimulado em comparação ao hemisfério não lesado e em comparação ao grupo não tratado. CONCLUSÕES: A recuperação motora induzida pela FES nestes animais foi acompanhada de modificações corticais representadas por uma maior imunorreatividade da MAP-2 no hemisfério lesado de animais tratados / INTRODUCTION: Stroke is the leading cause of disability and the third-leading cause of death among adults worldwide. The neural mechanisms involved in the acquisition of functionality and independence in the long term after stroke have been discussed in the literature. These include the reactivation of neuronal tissue from the penumbra, resolution of transhemispheric diaschisis, compensation of the affected areas by functional replacement behavior and also probably include the natural neuroplasticity of remaining preserved perilesional tissue. Functional electrical stimulation (FES) is used successfully since the 1960s for stimulation and acquisition of motor function after cortical ischaemic lesions found in stroke. In despite of this, little is known about the influence of FES on neuroplasticity involved with motor control. OBJECTIVES: This study aims to assess the functional improvement and changes in cortical neuroplasticity in rats with cerebral ischemia treated with an experimental model of FES. METHODS: We analyzed a group of eight rats with left hemiparesis after right cerebral cortical ischemia divided into two groups: A) without use of any therapy after the injury, and B) underwent a period 14 days of neuromotor stimulation using an experimental model of FES. For the clinical and functional evaluation were performed the Spontaneous Motor Behavior Analysis by Infrared and Foot Fault Test in times prior to injury after injury before stimulation and after 14 days of stimulation with FES. Plastic responses in these animals were analyzed by immunochemistry techniques with MAP-2 and NF 200 in the cortical areas and corpus callosum. All data were submitted to statistical analysis. RESULTS: There were statistical differences in Foot Faul Test, in Behavior Analysis with the Infrared and immunochemistry of MAP-2 in the comparison groups, while the STIMULATED group had a greater degree of motor recovery that UNSTIMULATED group. Analysis of MAP-2 demonstrated an increase in the immunochemistry of injured hemisphere of the STIMULATED group compared to the uninjured hemisphere and compared to the UNSTIMULATED group. CONCLUSIONS: FES-induced motor recovery in these animals was accompanied by cortical changes represented by increased immunoreactivity of MAP-2 in the injured hemisphere of treated animals
24

Efeitos da estimulação magnética transcraniana de repetição nas alucinações auditivas de pacientes com esquizofrenia super-refratária ao tratamento / Effects of repetitive transcranial magnetic stimulation on auditory hallucinations of patients with schizophrenia refractory to treatment

Rosa, Marina Odebrecht 04 July 2006 (has links)
Onze pacientes com diagnóstico de esquizofrenia pelo DSM-IV-TR e alucinações auditivas mesmo em uso de clozapina foram distribuídos aleatoriamente para receber estimulação magnética transcraniana de repetição (EMTr) ativa (n=6) ou inativa (n=5) no córtex têmporo-parietal esquerdo. Um total de 160 minutos de EMTr a 1 Hz foi administrada ao longo de 10 dias, 90% do limiar motor, com desenho paralelo, com pacientes e avaliadores cegos, em desenho controlado com grupo inativo. Houve um efeito de grupo significativo nos escores da escala de alucinações (realidade e influência: p=0,0360 e p=0,0493 respectivamente) e no subitem sintomas positivos da PANSS. A EMTr ativa em associação com clozapina pode ser administrada com segurança para tratar as alucinações auditivas. Embora a amostra consistia de pacientes extremamente refratários, estes resultados sugerem haver alguns efeitos da EMTr a 1 Hz no córtex têmporo-parietal esquerdo. / Eleven schizophrenics patients according to DSM-IV-TR criteria and experiencing auditory hallucinations in spite of treatment with clozapine were randomly allocated to receive repetitive transcranial magnetic stimulation (rTMS) (n=6) or sham stimulation (n=5) over left temporo-parietal cortex. A total of 160 minutes of 1 Hz rTMS was administered over 10 days at 90% motor threshold, with patients and raters blind to treatment modality, using a sham-controlled, parallel design. There was a significant group effect for the Auditory Hallucinations Rating Scale scores (reality and attencional salience: p=0.0360 and p=0.0493 respectively) and the sub item positive symptoms of PANSS. Active rTMS in association with clozapine can be administered safely to treat auditory hallucinations. Although the sample consisted of extremely refractory patients, the results suggest some effects of 1 Hz rTMS over Left temporoparietal.
25

Efeitos da eletroestimulação neuromuscular durante a imobilização nas propriedades mecânicas do músculo esquelético / Effects of neuromuscular electric stimulation during the immobilization in the mechanical properties of the skeletal muscle.

Matheus, João Paulo Chieregato 14 December 2005 (has links)
A estimulação elétrica neuromuscular (EENM) é um importante recurso utilizado na medicina esportiva para acelerar processos de recuperação. O objetivo deste estudo foi analisar os efeitos da EENM durante a imobilização do músculo gastrocnêmio, em posições de alongamento (LP) e encurtamento (SP). Para tanto, 60 ratas fêmeas jovens WISTAR foram distribuídas em seis grupos e acompanhadas durante 7 dias: controle (C), eletroestimuladas (EE), imobilizadas em encurtamento (ISP), imobilizadas em alongamento (ILP), imobilizadas em encurtamento e eletroestimuladas (ISP+EE) e imobilizadas em alongamento e eletroestimuladas (ILP+EE). Para a imobilização, o membro posterior direito foi envolvido por uma malha tubular e ataduras de algodão juntamente à atadura gessada. A EENM foi utilizada com uma freqüência de 50 Hz, 10 minutos por dia, totalizando 20 contrações em cada sessão. Após 7 dias os animais foram submetidos à eutanásia e os músculos gastrocnêmios foram retirados para a realização do ensaio mecânico de tração em uma máquina universal de ensaios (EMIC®). A partir dos gráficos carga versus alongamento foram calculadas as seguintes propriedades mecânicas: alongamento no limite de proporcionalidade (ALP), carga no limite de proporcionalidade (CLP), alongamento no limite máximo (ALM), carga no limite máximo (CLM) e rigidez. As imobilizações SP e LP promoveram reduções significativas (p<0,05) nas propriedades de ALP, CLP, ALM e CLM sendo mais acentuada, principalmente, no grupo ISP. Quando utilizada a EENM, houve acréscimo significativo (p<0,05) destas propriedades somente no grupo ISP. Já, em relação à rigidez, foi observada redução significativa (p<0,05) somente do grupo C para o grupo ISP. Quando utilizada a EENM, a rigidez do grupo ILP+EE foi significativamente (p<0,05) maior e mais próxima do grupo C que a do grupo ISP+EE. Neste modelo experimental, a imobilização dos músculos em alongamento atrasou a queda das propriedades e a estimulação elétrica, contribuiu para a manutenção das propriedades mecânicas durante o período de imobilização, principalmente no grupo ILP+EE. / The neuromuscular electric stimulation (NMES) is an important tool used in sport medicine to accelerate the recovery process. The objective of this study was to analyze the effects of NMES during the immobilization of the gastrocnemius muscle, in lengthened (LP) and shortened positions (SP). Sixty young female rats WISTAR were distributed into six groups and followed for 7 days: control (C), electric stimulation (ES), immobilized in shortened (ISP), immobilized in lengthened (ILP), immobilized in shortened and electric stimulation (ISP+ES) and immobilized in lengthened and electric stimulation (ILP+ES). For the immobilization, the right hind limb was involved by a tubular mesh and cotton rolls and plaster. NMES was used in a frequency of 50 Hz, 10 minutes a day, totaling 20 contractions in each session. After 7 days the animals were killed and their gastrocnemius muscles of the right side were submitted to a mechanical test in traction in an universal test machine (EMIC®). From the curves load versus elongation the following mechanical properties were obtained: elongation in the yield limit (EPL), load in the yield limit (LPL), elongation in the ultimate load (EUL), ultimate load (UL) and stiffness. The immobilizations SP and LP promoted significant reductions (p<0,05) in the properties of EPL, LPL, EUL and UL being more accentuated mainly in group ISP. When used NMES, there was significant increment (p<0,05) of such properties only in group ISP. As for stiffness, significant reduction was observed (p<0,05) only of the group C for group ISP. When the NMES was used, the stiffness of group ILP+EE was significantly (p<0,05) higher and closer to group C than for group ISP+EE. We conclude that in this experimental model the immobilization of the muscles in the lengthened position delayed the reduction of the properties and the electric stimulation contributed to the maintenance of the mechanical properties during the immobilization period, mainly for group ILP+ES.
26

Efeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanos

Rocha, Clarice Sperotto dos Santos, Vaz, Marco Aurelio January 2012 (has links)
O objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho. / The goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.
27

Efeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanos

Rocha, Clarice Sperotto dos Santos, Vaz, Marco Aurelio January 2012 (has links)
O objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho. / The goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.
28

Efeitos do uso da corrente interferencial no tratamento da dor decorrente de microlesão induzida por exercício excêntrico nos músculos flexores e extensores do joelho em humanos

Rocha, Clarice Sperotto dos Santos, Vaz, Marco Aurelio January 2012 (has links)
O objetivo do presente trabalho foi avaliar os efeitos da corrente interferencial na sensibilidade dolorosa e no torque muscular dos músculos flexores e extensores do joelho após a realização de um protocolo de exercícios excêntricos. A amostra foi constituída de 41 indivíduos saudáveis do sexo masculino com idade entre 18 e 33 anos, que foram divididos aleatoriamente em dois grupos experimentais: grupo corrente interferencial (n=21) e grupo placebo (n=20). Para indução da microlesão muscular, ambos os grupos realizaram 100 contrações musculares isocinéticas excêntricas máximas (10 séries de 10 repetições) dos músculos flexores e extensores do joelho na velocidade angular de 60°.s-1. No dia seguinte, os voluntários receberam tratamento com corrente interferencial ou tratamento placebo em ambos os grupos musculares. O tratamento foi realizado durante 30 minutos utilizando-se 4 kHz de frequência portadora (modulação de 80-150 Hz) e 125 μs de duração do pulso. O limiar de dor mecânica, o pico de torque e a concentração da proteína creatina cinase foram avaliados em quatro momentos diferentes: antes da indução da microlesão, imediatamente após o exercício, 24 horas após a indução e após o tratamento com corrente interferencial ou tratamento placebo. Tanto para os músculos flexores quanto extensores do joelho, ambos os grupos experimentais apresentaram uma redução significativa no pico de torque e no limiar de dor mecânica após a realização dos exercícios excêntricos, assim como uma elevação na concentração de proteínas marcadoras de lesão, mostrando que o protocolo de exercícios foi efetivo na indução da microlesão. Após o tratamento, apenas o grupo experimental, que recebeu a corrente interferencial, apresentou um aumento significativo no limiar de dor mecânica para ambos os grupos musculares avaliados, mostrando que a corrente foi efetiva na diminuição da sensibilidade dolorosa. Os valores de torque e a concentração das proteínas não sofreram alteração após o tratamento. Os resultados indicam que a corrente interferencial foi efetiva no tratamento da dor relacionada com microlesão muscular induzida por exercício excêntrico a partir de um aumento do limiar de dor mecânica nos músculos flexores e extensores do joelho. / The goal of the work presented here was to evaluate the effects of the interferential current in the pain sensibility and muscular torque of the flexor and extensor knee muscles after the performance of an eccentric exercise protocol. The sample was comprised of 41 healthy male individuals aged 18 to 33 years old, randomly divided into two experimental groups: interferential current group (n=21) and placebo group (n=20). To induce muscle soreness, both groups performed a hundred maximal isokinetic eccentric muscular contractions (10 series of 10 repetitions) in the flexor and extensor knee muscles, with an angular velocity of 60°.s- 1. On the following day volunteers were treated with interferential current or with the placebo treatment in both muscular groups. Treatment was carried out for 30 minutes using a 4 kHz carrier frequency (80-150 Hz) and a pulse duration of 125 μs. Mechanical pain threshold, peak torque and creatine kinase protein concentration were evaluated at four different times: before muscle soreness induction, immediately after exercise, 24 hours after induction and after the interferential current treatment or the placebo treatment. For both flexor and extensor knee muscles, both experimental groups presented a significant reduction in peak torque and mechanical pain threshold after performing the eccentric exercises, as well as a rise in injurysignaling protein concentration, demonstrating the efficiency of the exercise protocol in inducing muscle soreness. After treatment, only the experimental group that received the interferential current presented significant increases in mechanical pain threshold for both evaluated muscular groups, thus showing that the current was effective in diminishing pain sensitivity. Torque values and protein concentration underwent no changes after the treatment. The results pointed out that the interferential current was effective in the treatment of pain related to muscle soreness induced by eccentric exercise through an increase in mechanical pain threshold in the flexor and extensor knee muscles.
29

Efeito em curto prazo da corrente interferencial associado a cinesioterapia no tronco de paciente com acidente vascular encefálico

Andrade, Daniela da Costa Maia de 21 February 2018 (has links)
Introduction: Among the main causes of disability associated with stroke, are: impairment of voluntary movements, spasticity, pain and loss of selective activity of muscles responsible for trunk control. The use of interferential current (IFC) in stroke patients has been recently reported in the literature for managing pain and spasticity. Aims: 1. to identify the evidence from studies evaluating the effects of IFC in patients with central neurological diseases (a systematic review); 2. To determine the short-term effect of IF associated with kinesiotherapy on pain of stroke patients; 3. To investigate the short term effects of IFC associated with kinesiotherapy on motor performance and functional gains of the trunk of patients with stroke. Methods: 1) A systematic review of clinical trials on 8 databases (Medline, Scopus, Science Direct, Web of Science, CINAHL, Scielo, Cochrane Central Register and PEDro) was conducted by two investigators by using the following key-words: interferential current OR interferential current therapy OR interferential electrical stimulation OR interferential electrical stimulation therapy OR interferential therapy OR interferential stimulation. The Cochrane collaboration tool was used for methodological quality analysis. 2 and 3) A randomized, double-blinded, placebo-controlled, crossover-type clinical trial was performed. 36 stroke patients were recruited and randomly included in one of two groups: active IFC group (IFC application + kinesiotherapy of trunk) and placebo IFC group (30 minutes of placebo IFC + kinesiotherapy of trunk). Both groups received 10 session of treatment, twice a week, for 60 minutes, with 05 sessions at each treatment group and a washout period of one week between treatments. Results: 1) 2004 studies were found, but only two were included based on the proposed inclusion criteria. After one single session, IFC was effective in reducing pain and spasticity and at improving balance, gait and range of motion of stroke patients. 2 and 3) there was improvement in pain during movement, pain catastrophizing and reaching of the affected member, when comparing pre and post treatment averages. There was no change in fatigue, self-esteem, motivation, trunk control, posture, flexibility and muscle tone in both groups. Conclusion: IFC might have influenced the improvements in trunk control and motor performance of stroke patients when associated with kinesiotherapy. It is recommended that new studies with a higher number of sessions be conducted to better clarify the effects of IFC associated with kinesiotherapy. / Introdução: Entre as principais causas de incapacidades do AVE podemos citar: o comprometimento dos movimentos voluntários, a espasticidade, a dor e a perda da atividade seletiva dos músculos responsáveis pelo controle do tronco. O uso da corrente interferencial (CI) em pacientes com AVE tem sido reportado recentemente na literatura científica, na prática isolada, no tratamento da dor e na espasticidade. Objetivos: 1. Identificar a evidência dos estudos que avaliaram os efeitos da CI em pacientes com doenças neurológicas centrais (revisão sistemática); 2. Determinar o efeito da CI associado a cinesioterapia na dor dos pacientes com AVE; 3. Investigar a performance motora e ganhos funcionais do tronco dos pacientes com AVE após aplicação de CI associado a cinesioterapia. Método: 1) busca sistemática de estudos em 8 bases de dados (Medline, Scopus, Science Direct, Web of Science, CINAHL, Scielo, Cochrane Central Register e PEDro) realizada por dois investigadores, através dos descritores interferential current OR interferential current therapy OR interferential electrical stimulation OR interferential electrical stimulation therapy OR interferential therapy OR interferential stimulation. Para avaliação metodológica desses estudos, foi utilizada a ferramenta da Colaboração Cochrane. 2 e 3) Ensaio clínico randomizado, controlado por placebo e duplamente encoberto, do tipo crossover. Foram recrutados 36 pacientes com AVE, que foram aleatoriamente incluídos em um dos dois grupos de estudo: grupo CI Ativa (aplicação de CI por 30 minutos + cinesioterapia de tronco) e grupo CI Placebo (placebo da CI + cinesioterapia de tronco). Ambos os grupos receberam intervenção por 10 sessões, duas vezes por semana, 60 minutos, sendo 05 sessões para cada forma de tratamento e um período de washout de uma semana. Resultados: 1) Foram encontrados 2004 estudos, porém apenas dois artigos foram incluídos por seguirem os critérios de inclusão propostos. Após administração única, a CI mostrou-se eficaz na redução da dor, da espasticidade e na melhora do equilíbrio, da marcha e da amplitude de movimento de ombro de pacientes pós AVE. 2 e 3). Houve melhora na dor em movimento, catastrofização da dor e no alcance para o lado acometido quando comparadas as médias pré e pós-tratamento. Não houve alteração da fadiga, da autoestima, da motivação, do controle de tronco, da postura, da flexibilidade e do tônus em ambos os grupos. Conclusão: A CI pode ter influenciado a melhora do tronco e performance motora de pacientes pós AVE associado a cinesioterapia. Recomenda-se, assim, a realização de novos estudos com um maior número de sessões para melhor esclarecer os efeitos da CI associada a cinesioterapia. / São Cristóvão, SE
30

Influencia da eletroestimulação intravaginal e na qualidade de vida da mulheres com incontinencia urinaria / The influence of intravaginal electrical stimulation on vaginal ecosystem and quality of life on female urinary incontinence

Rett, Mariana Tirolli 13 August 2018 (has links)
Orientador: Paulo Cesar Giraldo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-13T17:48:41Z (GMT). No. of bitstreams: 1 Rett_MarianaTirolli_D.pdf: 1995626 bytes, checksum: 4efa60d32a9f7e4d934df9d4da99bb70 (MD5) Previous issue date: 2009 / Resumo: Objetivos: Avaliar o ecossistema vaginal e a qualidade de vida (QV) de mulheres com incotinência urinária (IU) submetidas a tratamento fisioterápico com eletroestimulção intravaginal (EEIV). Métodos: Estudo de ensaio clínico realizado entre setembro de 2006 a novembro de 2008 envolveu 67 mulheres com queixa clínica de IU. O tratamento fisioterápico consistiu de 8 sessões (2x/semana) de EEIV (frequência=35Hz, largura de pulso=0,5ms e tempo=20min), orientações comportamentais e exercícios de fortalecimento do assoalho pélvico. O ecossistema vaginal foi avaliado quanto ao tipo de flora, inflamação e pH da mucosa vaginal antes e após a EEIV. O conteúdo coletado do terço médio vaginal foi corado pela técnica de Gram e analisado sob microscopia óptica em flora bacilar ou normal, intermediária e, cocóide/ cocobacilar ou vaginose bacteriana (VB). A intensidade da inflamação foi determinada contando-se o número médio de células de defesa (polimorfonucleares neutrófilos e linfócitos) encontradas em 10 campos de grande aumento (400X). A QV foi avaliada pelo questionário "Consultation on Incontinence Questionnaire-Short Form" antes e após o tratamento. Os dados foram coletados pelo mesmo investigador e analisados por apenas um microbiólogo de forma cega. O estudo foi aprovado pelo Comitê de Ética em Pesquisa etodas as pacientes assinaram termo de consentimento livre e esclarecido. Resultados: Foram selecionadas 78 mulheres, sendo 11 excluídas para a análise microbiológica e 6 para análise da QV. Das 67 mulheres incluídas, a média de idade foi de 51,3 (±11,8) anos, a maioria branca, do lar, pós-menopausada e com sintomas de IUM (76,4%) e IUE (23,6%). Antes da EEIV, 43 mulheres apresentaram microbiota normal, 24 intermediária e nenhum caso de VB ou candidíase vaginal (CV). Após as 8 sessões de EEIV não houve mudança significativa da flora vaginal, sendo que das 43 mulheres que apresentaram flora normal, 36 permaneceram na mesma categoria, 5 apresentaram flora intermediária e 2 apresentaram VB. Das 24 identificadas com microbiota intermediária, 15 permaneceram na mesma categoria, 7 foram identificadas com microbiota normal e 2 com VB. O aparecimento de 4 casos de VB foi estatisticamente significativo (p<0,05). A análise do processo inflamatório identificou que 60 mulheres não apresentavam inflamação, 4 tinham inflamação leve/moderada e 3 inflamação intensa. Após o tratamento não houve mudança significativa, sendo que 58 mulheres não apresentavam inflamação, 6 apresentaram inflamação leve/moderada e 3 inflamação intensa. Também não foram encontradas diferenças significativas nos valores do pH antes e após cada sessão de EEIV. Para a avaliação da QV foram incluídas 72 mulheres. Encontrou-se uma redução significativa dos escores da frequência de perda urinária de 3,4(±1,4) para 1,4(±5,9) [p<0,03], da quantidade de perda urinária de 3,6(±1,6) para 2,0(±1,3) [p<0,04] e do impacto da IU na QV de 7,7(±2,4) para 3,8(±2,9) [p<0,001]. O escore total do ICIQ-SF diminuiu de 14,6(±4,2) para 7,2(±4,5) [p<0,001]. Conclusões: O ecossistema vaginal neste estudo não foi significativamente influenciado pela EEIV quanto ao tipo de flora vaginal, inflamação da mucosa vaginal, mudança do pH vaginal e aparecimento de CV, apesar de terem aparecido 4 casos de VB. A EEIV proporcionou uma melhora significativa na QV de mulheres com IU. / Abstract: Objectives: To evaluate vaginal ecosystem and quality of life (QOL) of women submitted to intravaginal electrical stimulation (IVES) as physicaltherapy treatment. Methods: A clinical trial was carried out from September 2006 to November 2008 including 67 women presenting IU as symptom. Physicaltherapy treatment consisted in 8 IVES sessions during 4 weeks (frequency=35Hz, pulse width=0,5ms, duration=20min), pelvic floor muscle exercises (PFME) and behavioral orientation. Vaginal ecosystem was assed concerning type of flora, inflammation and pH before and after treatment. Vaginal bacterioscopy swab was collected from e middle third of the vagina (vaginal smear was collected for subsequent Gram stain). The inflammatory process intensity was determined by the average number of white defense cells (neutrophils and limphocytes) found in 10 observation fields (magnified 400X). Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) was used to asses QoL. All data was collected by a single investigator and analyzed by the same microbiologist. This study was approved by Institutional Ethitics Committee and every patient signed an agreement term. Results: 78 women were selected and 11 were excluded from microbiologic analyzes and 6 from QoL analyses. Of the 67 women included, the mean age was 51.3(±12.2), most were white, housewives, post menopausal, presenting symptoms of MUI (76.4%) and SUI (23.6%). Before IVES 43 women had a normal vaginal flora, 24 presented intermediary flora and none had bacterial vaginoses (BV) or vaginal candidiasis (VC). After 8 sessions of IVES no significant alteration was noticed, 43 were unaltered, 36 remained in the same category, 5 showed intermediary microbiota and 2 were identified as having VB. Of those 24 initially identified as intermediary, 15 remained in the same category, 7 were normal and 2 with VB. Four cases of BV was statistically significant (p<0,05). The inflammatory process analyses identifiyed that 60 women did not present any inflammation, 4 had slight-moderate and 3 showed it as intense. No significant changes in pH were observed in the measurements before and after each IVES session. Also, it was observed a significant reduction in scores of frequency of leakage from 3.4(±1,4) to 1.4(±5.9) [p<0.03], amount of leakage from 3.6(±1.6) to 2.0(±1.3) [p<0.04] and impact of UI in Qol from 7.7(±2.4) to 3.8(±2.9) [p<0.001]. Total score ICIQ-SF decreased from 14.6(±4.2) to 7.2 (±4.5) [p<0.001]. Conclusion: No significant influence was observed in the vaginal ecosystem, inflammatory process, and vaginal pH after IVES, but 4 cases of BV were reported. The IVES provided a significant improvement in QoL of women with UI. / Doutorado / Tocoginecologia / Mestre em Tocoginecologia

Page generated in 0.5319 seconds