• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 341
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 1
  • Tagged with
  • 346
  • 146
  • 70
  • 65
  • 56
  • 56
  • 46
  • 41
  • 39
  • 37
  • 37
  • 34
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Estudos eletroquímicos envolvendo eletrodos modificados por metaloporfirinas e aplicação na determinação de nitrato (NO3-) e nitrito (NO2-) / Electrochemical studies involving electrodes modified by metalloporphyrins and application in the determination of nitrate (NO3-) and nitrite (NO2-)

Rocha, José Roberto Caetano da 06 February 2001 (has links)
O presente trabalho inclui duas etapas da pesquisa. Na primeira fase do projeto, a oxidação eletroquímica do nitrito em eletrodo de carbono vítreo modificado com um filme obtido eletrostaticamente de Co-TRP/Zn-TPPS, foi investigada em pH 4,7. Um aumento de corrente foi detectado em 0,75V, cujo máximo foi proporcional à concentração do íons nitrito, exibindo uma dependência inversa com a espessura do filme. A velocidade de transferência de carga foi avaliada por cronoamperometria, sendo que a velocidade de difusão da carga eletroquímica através do filme é mais alta do que a velodicade de difusão do íon em solução. O processo catalítico envolvendo a oxidação do íon nitrito no filme de pares de depósitos alternados foi também investigado com as técnicas da voltametria cíclica e de disco rotativo. Em concentrações relativamente baixas de substrato, o processo mediado foi tratado como um sub-caso, SR, na notação de Saveant, permitindo o cálculo da constante de velocidade para a reação de troca na interface filme-solução, sendo que tal valor foi estimado em 3,4x103 dm3 mol-1 s-1. Na segunda parte da investigação, a potencialidade analítica do eletrodo modificado foi confirmada por experimentos de injeção em fluxo usando solução carregadora tampão pH 4,7. Devido à atividade catalítica da camada imobilizada, a determinação de nitrito foi realizada em potencial menos positivo do que aqueles obtidos em eletrodos polidos (0,75 V vs. Ag/AgCl) e os dados obtidos demostraram o melhor desempenho do eletrodo modificado, indicando excelente repetibilidade e maior sensibilidade. Na condição experimental otimizada, o nitrito foi determinado na configuração FIA com limite de detecção de 0,1 &#181mol L-1 e a faixa analítica de aplicabilidade do método foi de 1 a 1000 µmol L-1. Nitrato também foi quantificado após sua redução estequiométrica a nitrito pela passagem da solução através da coluna de cádmio/cobre. Ambos analitos foram quantificados em água mineral e amostras de saliva e os resultados foram concordantes com aqueles obtidos usando método oficial. / This present work includes two research steps. ln the first step the electrochemical oxidation on nitrite on a glassy carbon disc electrode, modified with an electrostatically assembled film of tetraruthenated cobalt porphyrin/(meso-tetra(4-sulphonatephenyl)porphyrinate zinc(II), was investigated at pH = 4.7. A current enhancement was observed by using the modified electrode, the signal being proportional to the concentration of nitrite ions and exhibiting an inverse dependence with the film thickness. The charge transfer rate was evaluated by chronoamperometry, showing that the rate of diffusion of electrochemical charge through the film is higher than the rate of diffusion of substrates in solution. The catalytic process involving the oxidation of the nitrite ions at the bilayered film was also investigated based on cyclic and rotating disc voltammetry. At relatively low substrate concentrations the mediated process has been dealt with in terms of the SR sub-case in Saveant\'s notation, allowing the calculation of the rate constant for the cross-exchange reaction at the film-solution interface as 3.4x103 dm3 mol-1 s-1. In the second part the analytical potentiality of the modified electrode was studied by flow injection experiments carried out by using a pH 4.7 buffer as carrier solution. Owing to the catalytic activity of the immobilized layer, the determination of nitrite was performed at less positive potentials (0.75 V versus Ag/AgCl) and the data obtained showed a better performance indicated by both an excellent repeatability and increased sensitivity. At the optimized experimental condition, nitrite was determined in the FIA configuration with a limit of detection of 0.1 µmol L-1. Nitrate was also quantified after its stoichiometric reduction to nitrite by passing the solution through a cadmium/copper column. Both analytes were quantified in mineral water and saliva samples and the results were in agreement with the ones obtained by using an official method.
272

Fenômeno fotoeletrocatalítico mediada por UV/TiO2: da rápida imobilização do TiO2 P25 em eletrodos de ouro ao seu comportamento na fotooxidação do sistema modelo EDTA em células de camada delgada irradiadas por LED UV / The photoelectrocatalytic phenomenon mediated by UV/TiO2: from the quick immobilization of the P25 TiO2 on gold electrodes to its behavior on the photooxidation of the model system EDTA in thin layer-type cells irradiated by UV LED

Baccaro, Alexandre Luiz Bonizio 22 February 2017 (has links)
O demorado tratamento térmico, comum no preparo de fotocatalisadores e sua imobilização em substratos, foi contornado nesta tese, em que se investigaram duas estratégias de modificação de eletrodos de ouro com TiO2 P25. A primeira consiste em promover a formação de uma nanocamada pela simples exposição do metal por 1 min à suspensão aquosa de TiO2 (10 g L-1 em HCl 0,1 mol L-1); na segunda, deposita-se uma pequena alíquota (5 ou 8 µL) da suspensão diretamente no substrato (drop coating) para secá-lo em seguida por irradiação com lâmpada incandescente (60 W a 20 cm), obtendo-se bons resultados de uma a três camadas depositadas. Comprovou-se grande aumento da estabilidade da suspensão aquosa e duplicação da atividade fotocatalítica do nanofilme de TiO2 em decorrência da repulverização de P25 comercial em almofariz, melhoria inalcançável por sonicação da suspensão. O tamanho de partícula médio obtido por DLS para o TiO2 disperso em meio de HCl 0,1 mol L-1 atingiu 103±3 nm, enquanto que o filme depositado na superfície do ouro (observado por MEV e caracterizado por EDS) não ultrapassou 100 nm de espessura, sendo dominado por partículas de diâmetro de 20 (anatase) a 30 nm (rutilo), observadas por MET. A estabilidade da suspensão é susceptível ao ânion do ácido utilizado, sendo que resultados igualmente satisfatórios foram obtidos com HCl e HclO4 0,1 mol L-1, enquanto que para a mesma concentração de H2SO4 o TiO2 sofreu sedimentação rápida e o eletrodo preparado com a suspensão apresentou fotoatividade 10x menor. Filmes de espessuras bastante distintas (100 nm e 2 m) depositados a partir de suspensão 10 g L-1 por contato e drop coating com gota de 5,0 µL, respectivamente, foram comparados em relação à sua capacidade de transporte de elétrons e resposta eletroquímica ao Fe(CN)6 3 1,0 mmol L-1, sendo que a carga líquida formal de oxidação do EDTA 1,0 mmol L-1 é apenas 50 % maior para o filme 20x mais espesso, além de gerar distorções consideráveis nas ondas voltamétricas do sistema-sonda reversível em relação ao filme nanométrico e à superfície polida. Com eletrodos modificados pelo protocolo otimizado de drop coating (8,0 µL de TiO2 2 g L-1), testou-se o efeito da presença de diferentes eletrólitos de suporte (ácidos 0,1 mol L-1) em processos anódicos de fotooxidação em geral. A curva de decaimento da fotocorrente iph com o tempo pode ser descrita por uma equação de decaimento exponencial duplo iph = i0 + A1 exp(k1t) + A2 exp( k21t), permitindo distinguir as contribuições da fotocorrente de oxidação da água (i0) e de termos referentes a dois tipos de sítio superficiais, sendo um de cinética rápida e outro de cinética lenta. A seguinte ordem foi determinada para a fotocorrente total inicial (iph0 total) dos eletrólitos: HNO3 > HClO4 > HCl > H1SO4 > H3PO4 e as explicações propostas para tal se embasam na adsortividade dos ânions no TiO2 e na reatividade dos respectivos traps formados. O mesmo modelo de ajuste matemático foi utilizado para avaliar a fotoatividade do eletrodo modificado pela sua irradiação sucessiva e repetida em HNO3 0,1 mol L-1 (sem EDTA), sendo observada redução significativa principalmente nos parâmetros relativos aos sítios de reação e, assim, sugere-se um impedimento dos mesmos através, p. ex., da formação de peróxidos superficiais. Na presença também de EDTA, a carga líquida total despendida na sua fotooxidação se mantém relativamente constante nas sucessivas irradiações. Por fim, os experimentos de fotooxidação do EDTA sob varredura de potencial revelaram uma região de relação linear entre a fotocorrente e o potencial aplicado ao eletrodo modificado com TiO2 que se estende até a região de saturação de fotocorrente ser atingida, comportamento compatível com filmes nanoparticulados porosos não-dopados. A inclinação da região linear aumenta em função da [EDTA], como se os valores de condutância (di/dE) se elevassem dependendo da reação interfacial. Ajuste de modelo matemático hiperbólico correlacionando a (foto)resistência do filme em função da fotocorrente de saturação R = R0 + kIsph1, fornece resistência ôhmica do filme R0 de 5,0 kΩ e uma constante atrelada ao fotopotencial de 237 mA Ω. Já a curva monotônica de fotocorrente de saturação (Isph) com a [EDTA] apresenta comportamento linear até cerca de 0,7 mmol L-1, sugerindo-se que nessa região o controle por transporte de massa é a etapa limitante do processo global. Acima dessa concentração o coeficiente angular diminui gradualmente à medida que a reação de cinética de captura das lacunas passa a ser o determinante até um limite máximo (aparentemente 5,0 mmol L-1 de EDTA, nas condições do experimento) onde a disponibilidade de lacunas fotogeradas passa a governar. / The lengthy thermal treatment is a common step during the preparation and immobilization of photocatalysers on substrates, which by the way, was overcome in this thesis by the investigation of two strategies of modification of gold electrodes with P25 TiO2. The first one consists in promoting the formation of a nanolayer by the simple exposure of the metal surface to an aqueous suspension of TiO2 (10 g L-1 on 0.1 mol L-1 HCl) during 1 min; the second involves the deposition of a small drop (5 or 8 L) of the suspension on the gold substrate (drop coating) and its drying by irradiation with an incandescent lamp (60 W at 20 cm far), with worthy results also for two or three deposited layers. The stability of this aqueous suspension was appreciably improved by the repulverization of commercial P25 in a grinding mortar. As a consequence the photocatalytic activity conferred to the electrode by the formation of the TiO2 nanofilm doubled. Such improvements cannot be attained by bath sonication of the suspension. The average particle size determined by DLS for the TiO2 dispersed in 0.1 mol L-1 HCl was 103±3 nm, while the film deposited on the surface of gold consisted of particles of 20 nmn (anatase) and 30 nm (rutile) characterized by TEM and barely achieved a thickness of 100 nm (characterized by SEM and EDS). The stability of the modifying suspension is susceptible to the type of anion of the electrolyte. Good results were found with 0.1 mol L-1 HCl and HClO4, but not with 0.1 mol L-1 H2SO4. This last medium causes fast sedimentation of TiO2 and generates electrodes with one tenth of the photoactivity achieved with the other acids. The effect of film thickness on the photoactivity was evaluated for films with 100 nm and 2.0 µm prepared from a 10 g L-1 TiO2 suspension by the contact and drop coating (5 µL) strategies, respectively. The electron transport across both films and the electrochemical response for the 1.0 mmol L-1 Fe(CN) 63- probe was compared. The formal net charge for the 1.0 mmol L-1 EDTA oxidation was only 50 % higher for the 20x thicker film that also considerably distorts the voltammetric waves of the aforementioned reversible probe. The effect of different supporting electrolytes (0.1 mol L-1 acids) on the anodic photooxidation processes in general was tested with electrodes modified by an optimized drop coating protocol (8.0 µL of 2 µg L-1 TiO2). The curve describing the photocurrent decay in function of time might be ascribed to an equation of double exponential decay iph = i0 + A1 exp(k1t) + A2 exp (k2t), which allows the distinction of the contribution of water oxidation (i0) from terms of two types of surface sites: a kinetically fast site and a slow one. The total initial photocurrent (iph0 total) of the following electrolytes decays in the order: HNO3 > HClO4 > HCl > H2SO4 > H3PO4; explanations comprise the adsorbability of each respective anion on TiO2 and the reactivity of the corresponding traps formed. Similar curve fitting applied to the data of photoactivity of the gold electrode during successive irradiations of its surface in 0.1 mol L-1 HNO3 (absence of EDTA) revealed that sites reactivities underwent considerable reduction. It is suggested that during repetitive experiments the sites are impaired by the formation of surface peroxides. However, in the presence of 1.0 mmol L-1 of EDTA, the formal net charge of oxidation of the organic species remains almost unaltered. Ultimately, the experiments concerning the photooxidation of EDTA under linear potential scan revealed a region of linear relation between the photocurrent and the potential applied to the electrode modified with a TiO2 film (nanometric or micrometric), which holds until the saturation photocurrent is attained. This behavior is typical for porous non-doped nanoparticulate electrodes. The slope of the linear region increase somewhat with the EDTA concentration, as though the conductance values (di/dE) were raised depending on the interfacial reaction rate. The fitting of a hyperbolic model R = R0 + kIsph-1 for the correlation of the (photo)resistence (R) of the film with the photocurrent of saturation (Isph) allows the estimation of an ohmic resistance of 5.0 kΩ, and a photopotential related constant of 237 mA Ω. The curve of correlation between Isph and the [EDTA] is linear fit until 0.7 mmol L-1, suggesting that in this initial region the mass transport to the interface is the limiting step of the global process. Above that concentration, the slope of the curve is gradually reduced as the kinetic of capture of the holes becomes the determining step and from 5.0 mmol L-1 on an asymptotic Isph is reached (under the conditions of the experiments), where the holes photogeneration might start governing.
273

Nova abordagem na transmissão de energia transcutânea para dispositivos de assistência ventricular implantáveis / New Approach in Transcutaneous Energy Transmission for Implantable Ventricular Assist Devices

Silva, Evandro Drigo da 20 June 2018 (has links)
Com a crescente demanda por dispositivos implantáveis de suporte cardíaco (vulgarmente chamados de Coração Artificial) no tratamento da insuficiência cardíaca, surge a demanda por sistemas de transmissão de energia transcutânea (TET) para recarregamento das baterias implantadas. Esses sistemas reduzem os riscos de infecções, por não terem cabos atravessando a pele para alimentar os implantes; evitando também intervenções cirúrgicas reincidentes para troca de baterias. Normalmente, são pesquisados e testados sistemas TET por acoplamento magnético (indutivo) entre bobinas através da pele. Este trabalho propõe um modelo para o acoplamento por meio do campo elétrico, através de um capacitor, cujo dielétrico é constituído por polímeros (materiais biocompatíveis) e tecido biológico vivo (pele humana). Provas de conceito para transmissão de energia pelo acoplamento capacitivo apresentaram a possibilidade de mitigar problemas relacionados ao alinhamento axial exigido pelo acoplamento indutivo. Simulações computacionais de circuitos elétricos equivalentes ao acoplamento capacitivo foram confrontadas com experimentos in vitro e ex vivo, com tecidos vivos, validando o modelo proposto e servindo de base para o desenvolvimento de uma nova tecnologia. / Heart failure (HF) is a complex syndrome and a problem in the world. Ventricular assistive devices (VADs) are being used as target therapy in the treatment of HF. In order to avoid infectious due to the driveline passing through the patients, transcutaneous energy transmission systems (TET) have been developed to VADs. These TETs usually act by magnetic coupling between coils. The present work proposes a modeling for capacitive coupling through a dielectric composed of polymer and human skin. Bench tests demonstrated advantages over the axial alignment required by inductive systems. Computational simulations of the equivalent electric circuit for capacitive coupling were compared with in vitro experiments and validated the proposed model.
274

Caracterização eletroquímica e eletromodificação de superfícies de estanho em meio bicarbonato / Electrochemical characterization and electromodification of tin surfaces in bicarbonate medium

Mosca, Silvia Helena Bonilla 05 September 2001 (has links)
Medidas eletroquímicas, incluindo voltametria cíclica com e sem rotação do eletrodo, cronoamperometria, deconvolução experimental, aplicação de procedimentos eletroquímicos de envelhecimento e programas de perturbação de potencial foram empregadas no estudo eletroquímico da interface estanho/solução de bicarbonato de sódio 0,5 mol L-1. Os estudos preliminares evidenciaram a natureza complexa dos processos que ocorrem no sistema e várias séries de ensaios foram propostos a partir desses resultados. Observou-se o deslocamento do principal pico catódico, devido à mudanças das configurações de energia do filme, que foram analisadas mediante a aplicação de procedimentos de envelhecimento potenciostático e potenciodinâmico. A ocorrência de reativação em condições de baixa velocidade de varredura e a razão entre as cargas anódica e catódica sempre superior à unidade foram atribuídas à dissolução. O emprego de eletrodo de disco rotativo permitiu acompanhar a presença de espécies solúveis de Sn(II) envolvidas nos primeiros estágios de formação de filme. Foi observado que há contribuição difusional no controle da cinética dos dois primeiros processos anódicos. A variação da corrente com a rotação deve-se à difusão de uma mesma espécie nos dois processos anódicos. A presença de óxidos formados em diferentes condições experimentais com características e propriedades elétricas diferentes, evidenciada nos ensaios preliminares, foi analisada sob uma abordagem modelística. A ocorrência de processos de nucleação na redução, sugerida pela presença de histerese de corrente e pela dependência da corrente do pico de redução com a velocidade de varredura, foi confirmada com o emprego de medidas cronoamperométricas. Programas de perturbação de potencial, com o objetivo de eletromodificar a superfície do estanho, foram aplicados. A influência das variáveis de interesse (velocidade da perturbação, tempo de duração, limites de potencial, catodização e número de catodizações) no aparecimento de mudanças no perfil padrão foi estudada. A cinética de desprendimento de oxigênio foi analisada mediante curvas de Tafel, para avaliar as mudanças das propriedades eletrocatalíticas das superfícies resultantes da aplicação dos programas de perturbação. / Electrochemical measurements including cyclic voltammetry with and without electrode rotation, chronoamperometry, experimental deconvolution, electrochemical ageing procedures, and perturbing potential programmes, were carried out in order to study the tin/0,5 mol L-1 sodium bicarbonate solution interface. Preliminary studies evidence the complex nature of the processes and enable the proposal of various series of experiments. The potential shift of the main cathodic current peak was assigned to changes in the energetic configuration of the species formed during the positive scan. That effect was studied by means of potenciostatic and potentiodynamic ageing procedures. Reactivation occurrence at low sweep rates and the anodic to cathodic charges ratio always higher than one, were attributed to dissolution. Rotating disc measurements evidence the presence of soluble species, probably Sn(II) species, involved in the first steps of film formation. It was observed that a diffusional contribution has to be taken into account into the global control that involves the first two anodic processes. The same current-rotation dependence observed suggests the diffusion of the same species for both the anodic processes. The films formed under different experimental conditions, which exhibit differences in nature and electric properties, were studied under a modelistic approach. Current hysteresis presence as well as the dependence of peak current with sweep rate observed at the preliminary studies, suggest cathodic nucleation processes. Nucleation was confirmed by means of chronoamperometric measurements. In order to electromodify tin surface, the electrode was subjected to perturbing potential programmes. The influence of experimental variables (as perturbation sweep rate, perturbation time, potential limits, cathodic polarization and number of cathodic polarization applied) on the cathodic profile was studied. Oxygen evolution reaction, in terms of Tafel plots, was used in order to evaluate changes in the electrocatalytic properties of the modified surfaces.
275

Eletrodos quimicamente modificados com Poli (benzil viologênio): comportamento eletroquímico de fármacos nitroderivados. / Chemically modified electrodes with Poly (benzyl viologen): electrochemical behavior of nitro derivative drugs.

Deliberto, Laíla Aparecida 15 March 2013 (has links)
Na área da saúde, destacam-se alguns fármacos amplamente administrados, os quais possuem grupamentos nitro em suas moléculas, como o Clonazepam (CNZ), Nitrazepam (NTZ) e Nimesulida (Nimes). O CNZ e o NTZ são utilizados ilicitamente em coquetéis entorpecentes, fragilizando vítimas. A Nimes é anti-inflamatório amplamente administrado e frequentemente usado sem prescrição médica. As metodologias de detecção e quantificação destes fármacos são, na sua maioria, dispendiosas, desenvolvidas por HPLC, GC, etc. Poucos trabalhos utilizam determinação eletroanalítica e dentre eles, menos ainda utilizam eletrodos quimicamente modificados (EQMs). Os EQMs melhoram a seletividade e sensibilidade das análises. Dentre as formas de modificação, a metodologia de filmes poliméricos é muito versátil e possibilita o desenvolvimento de eletrodos específicos. Uma classe importante de polímeros é a dos derivados de viologênio, como o Poli (benzil viologênio) (PBV). Este polímero é empregado com diferentes finalidades. Possui três estados de oxidação, um deles; o PBV+ atua como mediador redox. E, a partir de experimentos prévios em nosso laboratório demonstrou ainda a possibilidade de atuar na redução de nitrocompostos. Neste sentido, este trabalho determinou as melhores condições experimentais para obtenção de um EQM com o PBV para seu emprego em análise e quantificação de fármacos nitroderivados (CNZ, NTZ e Nimes), bem como em amostras comerciais, utilizando a técnica de voltametria cíclica. Este trabalho contribuiu para o desenvolvimento de uma metodologia eficaz de modificação do eletrodo de carbono vítreo (CV) com o PBV sintetizado. Este método garantiu o controle da cobertura e a linearidade nas análises. Assim, o método foi padronizado com a aplicação de eletrólise por 30 s durante o terceiro ciclo em -0,4 V. A varredura adotada foi 50 mV s-1 de 0 a -0,8 V. Esse padrão forneceu de 2,0 a 3,0 nmol cm-2 de cobertura. O eletrodo CV-PBV não apresentou dificuldades na transferência de carga da superfície do eletrodo para o polímero, apesar do valor de k = 5,2 s-1 em tampão fosfato 0,1 mol L-1 pH 7,0. O valor do coeficiente difusional de cada fármaco foi determinado em tampão fosfato 0,1 mol L-1 pH 7,0. Os estudos de redução dos fármacos em diferentes pHs estão de acordo com o mecanismo descrito na literatura. Além disso, os resultados indicam que o eletrodo modificado diminui a influência do pH sobre a redução dos fármacos. As quantificações dos fármacos foram feitas por curvas padrões com os eletrodos CV e Au, polidos e modificados. As correntes foram lineares até a concentração de 120 mol L-1. A modificação do eletrodo de CV com o PBV diminuiu, no mínimo, em aprox. 80 mV o potencial de redução dos fármacos em pH 7,0 em relação ao eletrodo de CV polido. A exceção foi o eletrodo de ouro modificado (Au-PBV) na análise de Nimes. Pode-se ainda, atribuir à modificação do eletrodo com o PBV o aumento da sensibilidade das análises em comparação aos respectivos eletrodos polidos. Somente a determinação do NTZ não apresentou o mesmo efeito. O eletrodo CV-PBV foi empregado com sucesso na quantificação dos fármacos (NTZ, CNZ e Nimes) em amostras comerciais de Rivotril®, Sonebon® e Nimesulida - medicamento genérico. As quantificações apresentaram aproximadamente 100% de recuperação. A normalização das diferentes análises pelos valores das coberturas dos eletrodos mostrou uma curva analítica com boa correlação linear. Finalmente, os resultados apresentados neste trabalho sugerem a possibilidade de desenvolver eletrodos descartáveis. Estes eletrodos podem ser empregados na análise de substâncias utilizadas de forma ilícitas, neste caso, o coquetel chamado Boa noite Cinderela, para uso da perícia forense em análise amperométrica, no próprio local investigado. Estes eletrodos também podem ser aplicados nas indústrias farmacêuticas, nos setores de controle de qualidade de fármacos e medicamentos. / In health care, broadly administered drugs can be highlighted, which possess nitro group moieties within their molecules, such as the Clonazepam (CNZ), Nitrazepam (NTZ), and Nimesulide (Nimes). CNZ and NTZ are illicitly administered as part of narcotics drinks, weakening their victims. Nimes is an anti-inflammatory drug widely administered and often used in self-medication. Detection and quantification methods of these drugs are in the majority of cases costly and involve techniques such as HPLC, gas chromatography, etc. Only few studies have made use of electroanalytical determination, and among them, even fewer have made use of chemically modified electrodes (CME). CMEs improve selectivity and sensitivity of analysis. Among of modification methods, polymeric films are very versatile and make possible the development of specific electrodes. An important type of polymers comprise Viologen derivatives, such as Poly (benzyl viologen) (PBV). This polymer is used serving different purposes. This polymer has three oxidation states; one of them, PBV+, acts as a redox mediator. Also in addition, our group has provided evidence for the possibility of PBV+ to act reducing nitro compounds. In this way, in the present work it was determined the best experimental conditions for developing CME with PBV for further application in analysis and quantification of nitro derivative drugs (CNZ, NTZ and Nimes), as well as commercial samples, through the use of cyclic voltammetry technique. This work has contributed to the development of an effective methodology for the modification of glassy carbon (GC) electrodes with synthesized PBV. This method guaranteed the control of coverage and the linearity of the analysis. In this way, this method was standardized with a potential hold during the third cycle of about -0.4V for 30 sec. Scan rate of potential was 50 mV s-1, from 0 to -0.8 V. This method provided a coverage 2.0 to 3.0 nmol cm-2. The electrode GC-PBV did not show difficulties to charge transfer from the electrode surface to polymer, although the value of k was 5.2 s-1 in 0.1 mol L-1 phosphate buffer solution, pH 7.0. The difusional coefficient value of each drug was determined in 0.1 mol L-1 phosphate buffer solution, pH 7.0. Reduction studies of drugs in different pHs were in agreement with mechanisms described in the literature. Furthermore, results suggest that modified electrode decreased pH influence regarding drug reduction. Drug quantification was achieved from standard curves using GC and gold electrodes, polished and modified. Currents were linear up to 120 mol L-1. GC electrode modification with PBV decreased, at least, in approximately 80 mV, the drug potential reduction at pH 7.0 compared to respective polished electrode. The exception was found for gold modified electrode during Nimes analysis. It can be also attributed to modification with PBV the increase of analysis sensitivity when compared to respective polished electrodes. Only NTZ determination did not show the same effect. The GC-PBV was successfully employed for drug quantification (NTZ, CNZ and Nimes) from commercial samples, such as Rivotril®, Sonebon® and Nimesulide generic medicine. Drug quantification exhibited recovery close to 100%. Standardization of different analysis by electrode coverage value showed good linear correlation. Finally, results suggest the possibility to develop disposable electrodes. These electrodes can be employed to illicit substance analysis, in the present case, the narcotic drinks known in Brazil as Boa noite Cinderela, in addition to use in forensics during amperometic analysis at the site of investigation. Also, such electrodes could be used in pharmaceutical industries, for drug and medicine quality control.
276

Estudo da segurança e da estabilidade do implante de cabo-eletrodo atrial direito pela via epidemiocárdiaca através do seio transverso em modelo animal suíno / Evaluation of safety and stability of right atrial lead implantation by epimyocardial access through the transverse sinus in a swine model

Bueno, Sávia Christina Pereira 13 June 2013 (has links)
Introdução: Embora o implante de marcapasso atrioventricular pela via endovenosa seja considerado o estado da arte, situações clínicas e técnicas que podem impossibilitar o implante transvenoso de cabos-eletrodos têm sido cada vez mais frequentes, tornando-se necessária a proposição de abordagens cirúrgicas alternativas. Objetivos: O presente estudo visou o implante de marcapasso atrioventricular utilizando nova técnica para implante de cabo-eletrodo atrial no átrio direito, com o objetivo de avaliar no período intra-operatório e nos 30 primeiros dias de seguimento: a segurança e a reprodutibilidade do procedimento cirúrgico; a taxa de deslocamento dos cabos-eletrodos; as condições de estimulação e sensibilidade; as alterações morfológicas na cavidade pericárdica e as alterações histopatológicas epimiocárdicas. Métodos: Sob anestesia geral, foram operados 10 porcos adultos da raça Large White. Os cabos-eletrodos foram implantados, sob visão direta, no ventrículo esquerdo e no átrio direito, pelo seio transverso, através de toracotomia anterolateral esquerda. As condições de estimulação e de sensibilidade para os cabos-eletrodos atrial e ventricular, nas configurações unipolar e bipolar, foram avaliadas no intra-operatório, pós-operatório imediato, no 7º e 30º dias de pós-operatório. Ao final do estudo, os animais foram reoperados por toracotomia longitudinal mediana para observação das aderências pericárdicas e análise das condições histopatológicas da junção entre o cabo-eletrodo e o epimiocárdico. Resultados: Todos os animais permaneceram vivos até o último dia do estudo, não tendo ocorrido complicações intra-operatórias graves. As condições de estimulação e sensibilidade para os cabos-eletrodos atriais e ventriculares, nas configurações unipolar e bipolar, mantiveram-se estáveis ao longo do estudo e apresentaram comportamento semelhante. Notou-se aumento progressivo dos limiares atriais, variando de 0,50 ± 0,38 a 1,86 ± 1,31 volts nos períodos intra-operatório e 30o pós-operatório, respectivamente. Comportamento semelhante foi observado para os limiares ventriculares, que variaram de 0,43 ± 0,23 volts, no intra-operatório, a 1,22 ± 0,49 volts, no 30o pós-operatório. As medidas de impedância atrial e ventricular apresentaram uma discreta queda ao longo do tempo, sendo que a impedância atrial variou de 486,80 ± 126,35 a 385,0 ± 80,52 Ohms no período intra-operatório e 30o pós-operatório, respectivamente. A impedância ventricular variou de 700,40 ± 203,67 Ohms, no intra-operatório, a 409,30 ± 58,96 Ohms, no 30o pós-operatório. A sensibilidade, tanto em átrio quanto em ventrículo, mostrou-se estável a partir do pós-operatório imediato. A inspeção da cavidade pericárdica mostrou aderências em todos os animais e em todas as regiões avaliadas, não sendo observados derrame ou constrição pericárdica. A análise microscópica mostrou que o contato com os cabos-eletrodos provocou espessamento do epimiocárdio no átrio direito, ventrículo esquerdo e na artéria pulmonar. A cicatriz formada na junção entre o cabo-eletrodo e o epimiocárdio atrial foi semelhante à formada na região do implante dos cabos-eletrodos ventriculares. Conclusões: O implante do cabo-eletrodo atrial direito pelo seio transverso foi seguro e reprodutível. A efetividade do procedimento foi confirmada pelas condições estáveis de estimulação e de sensibilidade durante o período de seguimento pós-operatório. A única alteração morfológica encontrada na cavidade pericárdica foi a formação de aderências. Ocorreu adequada cicatrização na junção entre o cabo eletrodo e o epimiocárdio atrial / Introduction: Although transvenous access for atrioventricular pacemaker implantation is considered the state of the art, clinical and technical situations that may impede transvenous leads implantation have become increasingly common, making it necessary the proposal of new surgical approaches. Objectives: The present study was design to perform the implant of atrioventricular pacemaker using a new technique for placement of the atrial lead in the right atrium, aiming to evaluate in the intraoperative period and during the first 30 days of follow-up: the safety and reproducibility of the surgical procedure; lead dislodgment rate; conditions of pacing and sensing; morphological changes in the pericardium, as well as, histopathological changes in the epimyocardium. Methods: A total of 10 Large White adult pigs underwent pacemaker implantation under general anesthesia. By using an anterolateral thoracotomy, leads were implanted under visual guidance in the left ventricle and in the right atrium through the transverse sinus. Pacing and sensing parameters, in unipolar and bipolar modes, were obtained during the intraoperative and immediate postoperative period and on the 7th and the 30th postoperative day. At the end of the study, all animals underwent reoperation by thoracotomy through a median longitudinal sternotomy for evaluation of pericardial adhesions and histopathological analysis of the junction between the lead and epimyocardial wall. Results: All animals were alive until the end of the study and there were no serious intraoperative complications. Pacing and sensing parameters for atrial and ventricular leads in both unipolar and bipolar modes remain stable throughout the study and showed similar performance. We observed a progressive increase in atrial thresholds, ranging from 0.50 ± 0.38 to 1.86 ± 1.31 volts, during the intraoperative and on the 30-day postoperative, respectively. Similar result was observed for ventricular thresholds, which ranged from 0.43 ± 0.23 volts, intraoperatively, to 1.22 ± 0.49 volts on the 30-day postoperative. Atrial and ventricular impedance measurements decreased slightly over time, and the atrial impedance ranged from 486.80 ± 126.35 to 385.0 ± 80.52 Ohms during the intraoperative and on the 30-day postoperative, respectively. Ventricular impedance ranged from 700.40 ± 203.67 Ohms, intraoperatively, to 409.30 ± 58.96 Ohms, on the 30-day postoperative. Both atrial and ventricular sensing measurements remain stable since the immediate postoperative period. Pericardial adhesions were found in all animals and in all studied regions. There was no noticeable pericardial effusion or myocardial constriction. Microscopic analysis showed that contact with the electrode had caused thickening of the right atrium, left ventricle and pulmonary artery. Similar scar formation was found at the interface between atrial lead and epimyocardial, such as ventricular lead and epimyocardial. Conclusion: Implantation of the right atrial lead through the transverse sinus was safe and reproducible. The effectiveness of the procedure was confirmed by stable conditions of pacing and sensing parameters throughout the postoperative follow-up. Pericardial adhesion was the only change found in the pericardial morphology. There was adequate scar formation between the interface of atrial lead and the epimyocardial
277

Dispositivos para cristais piezelétricos de quartzo com eletrodos separados para estudos de processos físicos e químicos de superfícies e filmes depositados / Separated electrodes piezelectric quartz crystal devices for studies ogf physical and chemical process and film coated

Neves, Carlos Antonio 02 October 2000 (has links)
Este trabalho descreve o desenvolvimento de dispositivos usando cristais piezelétricos de quartzo com eletrodos separados (ESPC) que, através do monitoramento da freqüência de oscilação e do espectro de impedância, permitem estudar modificações superficiais do cristal. Para o monitoramento de freqüência de oscilação, usou-se um circuito oscilador TTL seguido por um freqüencímetro e por uma interface conectada a um microcomputador. Para o controle desta interface, foi desenvolvida uma biblioteca de ligação dinâmica e um programa em HP-VEE 4.0. Os espectros de impedância foram obtidos via programas que controlam um analisador de impedâncias via protocolo GPIB. O primeiro dispositivo presta-se a estudos de filmes depositados (DFD) e é feito em acrílico com eletrodos em latão posicionados a décimos de milímetros do cristal. Sua parte superior possui uma camisa de água para a termostatização. O segundo, semelhante ao primeiro, permite a modificação de superfície (DMS) de ESPC através da introdução de reagentes na fase gasosa. Os dois dispositivos foram caracterizados e o primeiro mostrou boa linearidade entre as massas depositadas e aquelas estimadas pela equação de Sauerbrey. O DFD foi utilizado para monitoramento em tempo não real da modificação superficial do cristal por N-[3-(trimetoxisilil)propil]-1,2-etanodiamina seguida por reação com ácido iodoacético. Os resultados mostraram evidências de aumento de massa e mudança nas propriedades viscoelásticas do filme. O DMS foi utilizado para monitoramento em tempo real da modificação superficial com trimetilclorosilano (TMCS) e dimetildiclorosilano (DMDCS). Com o TMCS, devido à formação de uma monocamada, não foi possível monitorar variações significativas de freqüência de oscilação. Com o DMDCS foi possível verificar a formação de poli(dimetilsiloxano). / This dissertation describes the development of devices based on separated-electrode piezoelectric quartz crystals (ESPC) to study surface modifications. This is accomplished by monitoring the oscillation frequency and impedance spectrum of the crystal in the cell. A TTL oscillator coupled to a frequency counter and a microcomputer interface is used for monitoring the oscillation frequency. A dynamic link library and HP-VEE 4.0 programs were developed to control the interface. Other programs were also developed to acquire the impedance spectra from a spectrum analyzer by using the GPIB protocol. The first device (DFD) is intended to study deposited films. It is made in Plexiglas, with brass electrodes positioned at a few tenths of millimeters from the crystal surface, and a thermostatic water jacket. The second device (DMS) is similar to the first one, but allows the use of corrosive reagents in the gas phase for surface modification. The performance of both devices was evaluated and the results showed good agreement between the deposited mass and the one predicted by Sauerbrey equation. The DFD was used for offline monitoring of the crystal surface modification by N-[3-(triethoxysilyl)propyl]-1,2-ethanediamine followed by iodoacetic acid. The results show evidences of mass and viscoelastic variations of the film. The DMS was used for on-line monitoring during surface modification with trimethylchlorosilane (TMCS) and dimethyldichlorosilane (DMDCS). Due to the monolayer formed by TMCS, no significant frequency variation could be observed. On the other hand, the polymerization of DMDCS could be monitored.
278

Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense / Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.

Menezes, Matheus Manoel Teles de 14 November 2014 (has links)
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito. / Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.
279

Desenvolvimento de dispositivos eletroquímicos baseados em papel para monitoramento não invasivo de lactato em suor / Development of wearable electrochemical paper-based devices for noninvasive monitoring of lactate in sweat

Gomes, Nathalia Oezau 22 February 2019 (has links)
O lactato é um metabólito chave formado pelo metabolismo anaeróbico da glicose nos músculos, e tem se tornado um biomarcador importante no âmbito clínico e esportivo. Atualmente, existem biossensores eletroquímicos portáteis que são capazes de determinar os níveis de lactato no organismo em tempo real. No entanto, tal método é invasivo uma vez que requer amostras de sangue. O presente projeto tem como objetivo desenvolver um biossensor eletroquímico descartável para detecção de lactato no suor. Para isto a configuração do dispositivo foi feita utilizando a celulose bacteriana como substrato para obtenção de um dispositivo que seja resistente à deformação mecânica, especialmente quando molhado e, também, permeável ao suor. A impressão dos eletrodos de carbono neste substrato foi efetuada utilizando o processo de serigrafia. Com os dispositivos produzidos foram realizados experimentos de voltametria cíclica e espectroscopia de impedância eletroquímica, a fim de caracterizar o sensor desenvolvido e investigar a influência do pré-tratamento eletroquímico na sua performance analítica. A partir da modificação da superfície eletródica com nanocubos de Azul da Prússia foi possível desenvolver um sensor eletroquímico para detecção de peróxido de hidrogênio. A cronoamperometria foi utilizada para a determinação da curva analítica para o peróxido de hidrogênio. Com todos os parâmetros da cronoamperometria otimizados, uma dependência linear da corrente catódica com a concentração de peróxido de hidrogênio foi obtida, com a equação: Ip = 0,1 + 4,30 [H2O2], com r2 = 0,999 (n = 3). Esta curva analítica mostrou que a metodologia apresenta um Limite de Detecção e de Quantificação de mol L-1 e mol L-1, respectivamente. Para a configuração do biossensor eletroquímico a enzima lactato oxidase foi incorporada à superfície do papel pelo método de ligação covalente. Adotando esta metodologia foi verificado um aumento da área eletroativa que possibilitou uma melhora significativa no desempenho do sensor desenvolvido. No qual se obteve uma região linear de 1-24,0 mmol L-1 em suor sintético, obtendo-se Limites de detecção e Quantificação de e mol L-1. Tais parâmetros se mostraram adequados já que o suor pode apresentar níveis de aproximadamente 25 mmol L-1 de lactato. De modo geral, foi possível desenvolver uma plataforma eletroquímica no substrato de celulose bacteriana para a detecção de lactato em amostras de suor sintético. O dispositivo desenvolvido apresentou uma boa durabilidade e resistência ao se executarem sucessivas medidas corroborando a viabilidade deste substrato na projeção de sensores vestíveis para a aplicação direta na pele e monitoramento dos níveis de lactato em tempo real. / Lactate is a key metabolite formed in the anaerobic metabolism of glucose in the muscles. It has become an important biomarker in the clinical and sport scopes. Currently, there are portable biosensors that are able to determine lactate levels in real time. However, these methods are invasive since they require blood samples. Herein, we aim to develop a disposable wearable electrochemical biosensor for detection of lactate in sweat. For this purpose the configuration of the device was made with bacterial cellulose substrate in order to be permeable to sweat and resistant to mechanical deformation, especially when wet. The fabrication of the electrodes was made through screen printing technique. Electrochemical impedance spectroscopy and cyclic voltammetry were used to characterize the sensor developed in order to investigate the influence of the electrochemical pre-treatment in the analytical performance of the electrodes. To develop an electrochemical sensor for the detection of hydrogen peroxide the screen printed electrode was modified with Prussian blue nanocubes. Chronoamperometry experiments were used to detect of hydrogen peroxide. From optimized chronoamperometry parameters, a linear dependence of the cathodic current with the hydrogen peroxide concentration was obtained with the equation: Ip = 0.1 + 4.30 [H2O2], with r2 = 0.999 (n = 3). The limit of detection (LOD) and the limit of quantification (LOQ) were mol L-1 e mol L-1, respectively. For the configuration of the electrochemical biosensor the lactate oxidase enzyme was immobilized on the paper surface by the covalent bonding method. Adopting this methodology was verified an increase of the electroactive area that allowed a significant improvement in the performance of the developed sensor. In which a linear concentration range of 1-24.0 mmol L-1 was obtained in the synthetic sweat, obtaining LOD and LOQ of mol L-1 e mol L-1, respectively. Such parameters were adequate since sweat may have lactate levels of approximately 25 mmol L-1. Finally, it was possible to develop an electrochemical platform using the bacterial cellulose substrate for the detection of lactate in samples of synthetic sweat. The developed device presented a good durability and resistance when performing electrochemical measurements assuring the feasibility of this substrate in the projection of wearable sensors for the direct application to skin and monitoring of lactate levels in real time.
280

Desenvolvimento de métodos voltamétricos para a quantificação de LSD utilizando-se o eletrodo de pasta de carbono modificado com complexo de base de Schiff / Development of voltammetric methods for the quantification of LSD using a carbon paste electrode modified by a Schiff base complex

Ribeiro, Maria Fernanda Muzetti 29 October 2015 (has links)
Nos últimos anos, vários métodos eletroanalíticos foram desenvolvidos a fim de tornarem mais práticas e acessíveis às análises químicas de substâncias entorpecentes realizadas pela polícia científica. Com a sensibilidade e seletividade compatíveis com as dos métodos instrumentais convencionais, é a portabilidade da técnica eletroanalítica que se sobressai e tem apresentado grande potencial para tais aplicações. O uso de complexos metálicos com as bases de Schiff como modificadores do eletrodo de trabalho, tornou ainda mais promissora a utilização destes métodos para a detecção e quantificação de entorpecentes. Os eletrodos de pasta de carbono também contribuem para a praticidade da eletroanalítica, uma vez que são produzidos de forma simples e barata. Desta forma, neste projeto foram desenvolvidos métodos voltamétricos para a quantificação da dietilamida do ácido lisérgico (LSD), utilizando-se o eletrodo de pasta de carbono modificado com o complexo [UO2(Ac-ophen)]·H2O. A aplicação do KCl como eletrólito suporte, em solução aquosa, diferencia estes métodos do encontrado na literatura. Nas análises, foram empregadas as técnicas de voltametria cíclica, onda quadrada e de pulso diferencial. A linearidade no aumento da corrente frente às variações da concentração do LSD possibilitou a obtenção das curvas analíticas com desvio padrão e limites de detecção e quantificação de 2,45, 0,62 e 1,02 mol L-1, respectivamente, como melhores resultados. As análises de recuperação das amostras, 103 e 108%, demostra a possibilidade da utilização destas no âmbito forense. / The development of electroanalytical methods for forensic science has been growing in recent years by the fact of their practicality and low cost. Once sensibility and selectivity values are compatible to conventional methods, as chromatography and spectrometry, the portability of this system consists on interesting advantages. The simple modification of the carbon paste working electrode with Schiff bases complexes became even more promising to use this method for the detection and quantification of narcotics. The carbon paste electrode itself contributes for the practicality of the analyses, once it is made of simple carbon powder, which can be disposable. This project aimed to develop voltammetric methods for the quantification of the lysergic acid diethylamide (LSD) using a carbon paste electrode modified with the complex [UO2(Ac-ophen)]·H2O. The use of aqueous solution of KCl as supporting electrolyte characterizes a less pollutant methodology, differently of other methods that still use toxic solvents The combination of the differential pulse and square wave voltammetries with the modified carbon paste was crucial for the detection of trace levels of the LSD. The linear response in various concentrations of LSD results on analytical curves with standard deviation, detection, and quantification limits of 2,45, 0,62, 1,02 mol L-1, respectively. And the recovery values of 103 and 108 % indicates the possibility of using this method in the forensic science

Page generated in 0.0472 seconds