• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 341
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 1
  • Tagged with
  • 346
  • 146
  • 70
  • 65
  • 56
  • 56
  • 46
  • 41
  • 39
  • 37
  • 37
  • 34
  • 28
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Oliveira, Laura Siqueira de 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
292

Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymers

Clarindo, José Eduardo dos Santos 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
293

Desenvolvimento de eletrodos de pasta de carbono modificados com filmes de azul da prússia / Development of carbon paste electrodes modified with Prussian Blue films

Ivama, Viviane Midori 24 February 2003 (has links)
Os eletrodos de pasta de carbono modificados com Azul da Prússia foram preparados usando a voltametria cíclica, deposição a um potencial controlado e a deposição a dois potenciais controlados. O último método foi melhor e produziu eletrodos modificados com alta sensibilidade e estabilidade durante a redução catalítica de peróxido de hidrogênio. A composição da solução modificadora foi 3,0 mmol L-1 de FeCl3 e 2,0 mmol L-1 de K3[Fe(CN)6] em pH 2,0 com HCI. O sistema de eletrodos foi imerso na solução modificadora e + 0,4 V foi aplicado no eletrodo de trabalho durante 2 minutos. Depois, o potencial foi revertido para - 0,4 V por mais 2 minutos. O processo total foi repetido mais duas vezes. Além disso, para melhorar a estabilidade dos eletrodos de pasta de carbono modificados com Azul da Prússia (EPC-AP), estes foram ciclados em solução contendo 1,0 m mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI na faixa de potencial - 0,4V ≤ Eapl ≤ 0,6V a 60 mV s-1 (50 ciclos). Estes eletrodos, denominados de EPC-AP-Rh, foram secos a temperatura ambiente por 24 horas antes de serem utilizados. Os EPC-AP-Rh apresentaram boa estabilidade durante sucessivos ciclos, com os picos anódico e catódico, referentes a 0,30 V e 0,18 V inicialmente atribuídos para um processo redox envolvendo Branco da Prússia / Azul da Prússia. Cálculos com (Ep,a + Ep,c / 2), é 0,24 V. Em solução tampão citrato de potássio / ácido cítrico contendo 0,5 mol L-1 de KCI, pH 6,1, as correntes de picos variam linearmente com a velocidade de varredura 0,025 Vs-1 ≤ ν ≤ 0,400 V s-1 mostrando que o processo é governado por difusão de íons do eletrólito suporte para a superfície do eletrodo (durante a etapa de redução) ou do eletrodo para a solução (durante a etapa de oxidação) para manter a eletroneutralidade. O excesso superficial foi 4,3 10-8 mol cm-2, calculado usando a carga anódica obtida pelo voltamograma cíclico, depois da subtração do fundo de carga referente a um eletrodo não modificado de pasta de carbono em solução eletrólito suporte (1,0 x 10-3 mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI, ν = 60 mV s-1). O eletrólito suporte usado para detecção para determinação de peróxido de hidrogênio foi o tampão10 mmol L-1 de citrato de potássio/ 2 mmol L-1 de ácido cítrico, pH 6,1 (força iônica= 0,16 mol L-1) contendo 0,5 mol L-1 de KCI. A ausência deste eletrólito ou a presença de íons fosfatos diminui a estabilidade deste sensor. Peróxido de hidrogênio foi determinado a 0,04 V (vs EAg/AgCI, KCI sat) na faixa linear de 5,1 x 10-5 mol L-1 a 8,6 x 10-4 mol L-1 com sensibilidade média de 1,4 ± 0,2 A mol-1 L cm-2 e limite de detecção de (2,5 ± 0,02) x 10-5 mol L-1. Neste potencial aplicado a contribuição da corrente de redução do oxigênio foi de 8,0 % na presença de 1,0 mmol L-1 de H2O2. Curvas analíticas obtidas durante a determinação de peróxidos de hidrogênio ao longo de 5 dias, cada curva analítica representa uma média de 6 curvas amperométricas consecutivas, que desempenhou em cada dia, apresentando uma diminuição de somente 27% na sensibilidade do eletrodo modificado. Quando fora de uso o eletrodo foi armazenado em solução 0,5 mol L-1 de KCI. A um potencial aplicado de 0,04 V não foi detectada uma interferência do mediador ou oxidação direta do ácido úrico. A interferência de ácido ascórbico foi apenas significativa para potenciais iguais ou superiores a 0,060 V. / Prussian Blue carbon paste modified electrodes were prepared using cyclic voltammetry and deposition atone and two controlled potentials. The last method was the best and produced modified electrodes with higher sensitivity and stability during the catalytic reduction of hydrogen peroxide. The composition of the modifying solution was 3.0 mmol L-1 FeCl3, 2.0 mmol L-1 K3[Fe(CN)6] in pH 2.0 with HCI. The electrode system was immersed in the modifying solution and + 0.4 V was applied to the working electrode during two minutes. After, the potential was just reverted to - 0.4 V once more two minutes. The total process was repeated twice. Further, to improve the stability of the Prussian Blue carbon paste modified electrodes (PB-CPME), they were cycled in a solution containing 1.0 mmol L-1 RhCl3, 0,05 mol L-1 KCI and 0.02 mol L-1 HCI in a - 0.4 ≤ E ≤ 0.6 V potential range at 60 mV s-1 (50 cycles). These electrodes, denominated of Rh-PBCPME, were dried at ambient temperature during 24 hours before use. The Rh-PBCPME shows good stability during successive cycles, with anodic and cathodic peaks recorded at 0.30 V and 0.18 V being attributed to a redox process involving Prussian White / Prussian Blue couple. Em, calculated as (Ep,a + Ep,c/2), is 0.24 V. In potassium citrate/ citric acid buffer solution containing 0.5 mol L-1 KCI, pH 6.1, the peak currents changed linearly with the square of sweep velocity in the range 0.025 Vs-1 ≤ v ≤ 0.400 Vs-1 showing that the process is governed by ion diffusion from support electrolyte to the electrode surface (during the reduction step) or from the electrode to the solution (during the oxidation step) to ensure the electroneutrality rule. The modifier surface excess was 4.3 x 10-8 mol cm-2, calculated using the anodic charge obtained from cyclic voltammograms, after subtraction of the background charge recorded with an unmodified carbon paste electrode in an electrolyte support solution (1.0 mmol L-1 RhCl3, 0.5 mol L-1 KCI and 0.02 mol L-1 HCI, v = 60 mV s-1). The supporting electrolyte used to detection of hydrogen peroxide was 10 mmol L-1 potassium citrate/ 2 mmol L-1 Citric acid buffer, pH 6.1 (ionic strength = 0.16 mol L-1) containing 0.5 mol L-1 KCI. The absence of this electrolyte or the presence of phosphate ions decreased the stability of the sensor. Hydrogen peroxide was detected at 0.04V (vs EAg/AgCI, KCI sat) in 5.1 x 10-5 - 8.6 x 10-4 mol L-1 linear range with sensitivity of 1.4 ± 0.2) A mo1-1 L cm-2 and detection limit of (2.5 ± 0.02) x 10-5 mol L-1. At this applied potential the contribution of oxygen reduction current was 8.0 % in the presence of 1.0 mmol L-1 H2O2. Analytical curves obtained during hydrogen peroxide detections along 5 days, ach one of them representing an average of 6 consecutive amperometric analytical curves, carried out in the same day, showed a decrease of only 27 % in the sensitivity of the modified electrodes. When was not using the electrode was kept, 0.5 mol L-1 KCI. At 0.04 V applied potential no interference was detected due to mediated or direct oxidation of uric acid. The interference of ascorbic acid was only significant to 0.060 V or higher applied potentials.
294

Desenvolvimento e aplicação de eletrodos de difusão gasosa (EDG) modificados com óxidos bimetálicos de Ru e Nb em carbono amorfo para a eletrogeração de H2O2 / Development and application of gas diffusion electrodes (EDG) modified with bimetallic oxides of Ru and Nb in amorphous carbon for H2O2 electrogeneration.

Valim, Ricardo Bertholo 15 December 2016 (has links)
Neste trabalho foram estudadas a atividade e seletividade de materiais bimetálicos de rutênio e nióbio, adicionados em matriz de carbono do tipo Printex 6L, para a eletrogeração de peróxido de hidrogênio a partir da reação de redução de oxigênio. Os materiais foram caracterizados por aplicação de técnicas eletroquímicas em microcamada porosa e em eletrodos de difusão gasosa, em meio ácido. Foram realizados estudos de caracterização física e morfológica dos materiais para a compreensão dos possíveis óxidos formados em substrato de carbono, por análises de difração de Raios-X, por fluorescência de Raios-X, por microscopia eletrônica de varredura acoplada a um sistema de espectroscopia de Raios-X por dispersão de energia. Por caracterização eletroquímica em microcamada porosa, o material com 5,0% de Ru05%Nb95%Oz em carbono foi escolhido como o material com maior seletividade para a eletrogeração de peróxido de hidrogênio, com eficiência de corrente calculada de 84,6%, em potencial aplicado de -0,515 V (vs. Ag/AgCl), sendo posteriormente estudado em eletrodo de difusão gasosa, por cronopotenciometria, com concentração de peróxido de hidrogênio eletrogerado de 210,74 mg L-1, em 90 minutos de experimento, com uma densidade de corrente de -100 mA cm-2, cerca de 24,5% maior quando comparada a eletrogeração de H2O2 detectada para a matriz de carbono térmico, sem adição de elementos metálicos, nas mesmas condições experimentais. Os resultados de constante cinética obtidos na mesma densidade de corrente aplicada de -100 mA cm-2, foram: de 2,44 mg L-1 min-1 para o material com 5,0% de Ru05%Nb95%Oz, e de 1,78 mg L-1 min-1 para o eletrodo de difusão gasosa sem modificador. / In this work, the activity and selectivity of bimetallic materials composed by ruthenium and niobium, added on carbon matrix Printex 6L, for electrogeneration of hydrogen peroxide from oxygen reduction reaction. The materials were characterized by the application of electrochemical techniques in porous microlayer and gas diffusion electrodes, in acid medium. The physical and morphological characterization were made of the materials for understanding the possible metallic oxides formation in carbon substrate by analysis of X-rays diffraction , X-rays fluorescence , by scanning electron microscopy coupled by an energy-dispersive X-ray spectroscopy. For electrochemical characterization using porous microlayer, the material with 5.0% of Ru05%Nb95%Oz in carbon was chosen as the material with greater selectivity for the hydrogen peroxide electrogeneration, with calculated current efficiency of 84.6% in applied potential of -0.515 V (vs. Ag/AgCl), studied using a gas diffusion electrode, by chronopotentiometry, with obtained hydrogen peroxide concentration of 210.74 mg L-1, at 90 minutes of experiment, with a the current density of -100 mA cm-2, about 24.5% higher when compared with the hydrogen peroxide electrogeneration detected for a carbon matrix, without addition of metal elements, under the same experimental conditions. The results obtained for calculated kinetic constant, using the same applied current density of -100 mA cm-2: 2.44 mg L-1 min-1 for using the material with 5.0% Ru05%Nb95%Oz, and 1.78 mg L-1 min-1 for using the carbon matrix without modification.
295

Detecção e quantificação eletroquímica de substâncias de interesse clínico, ambiental e forense utilizando eletrodo de pasta de grafite modificado com trisilanol poss ligado a suportes porosos e eletrodos impressos obtidos via screen-printed / Electrochemical detection and quantification of clinical, environmental and forensic interest substances using carbon paste electrode modified with trisilanol-poss bonded to porous supports and screen-printed electrodes

Cumba, Loanda Raquel [UNESP] 04 March 2016 (has links)
Submitted by LOANDA RAQUEL CUMBA null (loandacumba@gmail.com) on 2016-04-18T17:28:50Z No. of bitstreams: 1 Tese Final - Loanda Cumba (2016).pdf: 4586367 bytes, checksum: c39a78169180c1ccedbe3f393fccbaee (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-04-19T16:39:26Z (GMT) No. of bitstreams: 1 cumba_lr_dr_ilha.pdf: 4586367 bytes, checksum: c39a78169180c1ccedbe3f393fccbaee (MD5) / Made available in DSpace on 2016-04-19T16:39:26Z (GMT). No. of bitstreams: 1 cumba_lr_dr_ilha.pdf: 4586367 bytes, checksum: c39a78169180c1ccedbe3f393fccbaee (MD5) Previous issue date: 2016-03-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho descreve a preparação, caracterização e aplicação eletroanalítica de um metalosilsesquioxano ligado em uma sílica mesoporosa (MCM-41) e em uma zeólita (H-FAU-Si/Al 40) com hexacianoferrato de níquel adsorvido em sua superfície. Algumas técnicas espectroscópicas como: Espectroscopia no infravermelho por transformada de Fourier (FTIR), Microscopia eletrônica de varredura (MEV), Espectroscopia por Energia Dispersiva de Raios X (EDS) e Voltametria cíclica, foram utilizadas na caracterização dos materiais formados. Os espectros na região do Infravermelho para o MTTiPNiH e ZTTiPNiH apresentaram as bandas de seus precursores (TTiP, MCM-41 e H-FAU-Si/Al 40), apenas duas absorções diferiram dos demais espectros, uma em, aproximadamente, 2168 cm-1 e outra a 2098 cm-1, tais resultados foram atribuídos ao estiramento ν (C≡N). Para o MTTIPNiH, através das micrografias pode-se observar partículas com tamanhos variados, entre 0,30 µm a 0,60 µm. Para o ZTTiPNiH as micrografias apresentaram um pequeno aumento no tamanho de partículas, aproximadamente de 50 nm, quando comparado a seus precursores. O EDS determinou a composição química semi-quantitativa dos elementos carbono, oxigênio, silício, titânio, fósforo, níquel e ferro, presentes em ambas as amostras. O eletrodo de pasta de grafite exibiu um par redox bem definido com potencial de médio padrão (E°’) de +0,53 V e +0,51 V para o MTTiPNiH e ZTTiPNiH, respectivamente, atribuído ao processo redox FeII(CN)6 / FeIII(CN)6 em presença de níquel. O eletrodo de pasta de grafite modificado com MTTiPNiH apresentou atividade eletrocatalítica para dipirona e para o sulfito, já o eletrodo de pasta de grafite modificado com ZTTiPNiH apresentou atividade eletrocatalítica apenas para o sulfito. Em uma segunda etapa, prepararam-se eletrodos impressos via screen-printed para detecção e quantificação de pindolol utilizando a técnica de voltametria de onda quadrada em uma faixa de concentração de 0,10 µmol L-1 – 10,0 µmol L-1. Após a detecção de pindolol, o protocolo de detecção foi utilizado na avaliação e recuperação desta substância a partir de urina humana. Eletrodos impressos via screen-printed foram empregados pela primeira vez na detecção da substância psicoativa Synthacaine. A detecção eletroquímica indireta para MPA/2-AI simultaneamente, utilizando eletrodos impressos apresentou resultados satisfatórios. Após a detecção simultânea de MPA e 2-AI, amostras reais de Synthacaine foram utilizadas para quantificar, através de técnicas eletroquímicas, estes analitos por meio do protocolo de detecção anteriormente proposto. / This research describes the preparation, characterization and electroanalytical application of a metalosilsesquioxane bonded in mesoporous silica (MCM-41) and in zeolite (H-FAU-Si/Al 40) with nickel hexacyanoferrate adsorbed on their surface. Techniques as fourier transform infra-red spectroscopy (FTIR), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS) and cyclic voltammetry were used in the characterization of the synthesized materials. The spectra in the infrared region for MTTiPNiH and ZTTiPNiH showed the bands of their precursors (TTiP, MCM-41 and H-FAU Si/Al 40), only two absorption differed from the others spectra, one at, approximately, 2168 cm-1 and another at 2098 cm-1 , which were attributed to stretching ν(C≡N). For MTTIPNiH through the micrographs can be observed particles with varied sizes between 0.30 µM to 0.60 µm. For ZTTiPNiH the micrographs showed a small increase in particle size, approximately, 50 nm, as compared to their precursors. EDS determined the semi-quantitative chemical composition of carbon, oxygen, silicon, titanium, phosphorus, nickel and iron present in both samples. The carbon paste electrode exhibited a well-defined redox couple with E°' = +0.53 V and +0.51 V for MTTiPNiH and ZTTiPNiH, respectively, attributed to the redox process FeII(CN)6 / FeIII(CN)6 in presence of nickel. Carbon paste electrode modified with MTTiPNiH showed electrocatalytic activity to dipyrone and sulfite. However the carbon paste electrode modified with ZTTiPNiH showed electrocatalytic activity only for sulfite. In a second step, screenprinted electrodes were produced for the detection and quantification of pindolol using square wave voltammetry technique at a concentration range of 0.10 µmol L-1 to 10.0 µmol L-1 . After pindolol detection, the protocol of detection was used in the evaluation and recovery of pindolol from human urine. Screen-printed electrodes were used for the first time in the detection of psychoactive substance Synthacaine. Indirect electrochemical detection for MPA/2-AI simultaneously, using Screen-printed electrodes showed satisfactory results. After the simultaneous detection of MPA and 2-AI, real samples of Synthacaine were used to quantify through electrochemical techniques, these analytes by protocol of detection previously proposed.
296

Desenvolvimento de uma família de reatores eletrônicos para lâmpadas fluorescentes sem eletrodos empregando a técnica de integração de conversores / Development of an electronic ballast family to feed electrodeless fluorescent lamps applying the integration technique of converters

Silva, Marcelo Freitas da 30 November 2012 (has links)
This paper presents the design and development of an electronic ballasts family obtained through the use of the integration technique of converters for feeding the electrodeless fluorescents lamps (EFL). This type of lamp is driven by electromagnetic effects and because of this the electrodes are eliminated. Thus, the EFL has longer lifetime associated with low lumen depreciation representing an alternative to lighting systems among other discharge lamps. It is necessary to develop an electrical model capable of describing the behavior of the lamp in order to design electronic circuits to provide a good operation. In this work, the developed model includes not only, the lamp static behavior at different operating points, but also the magnetic losses involved. Because of the EFL magnetic characteristics, the operation frequency of this type of system has to be high in order to reduce the size of inductive elements avoiding the glare. Due to this, it is proposed a set of electronic systems for feeding the lamp in an efficient way. The systems are studied to establish relationships regarding the behavior and limitations imposed by them. This work also presents the power control delivered to the lamp. Finally, experimental results are presented in order to validate the developed project. / Este trabalho apresenta o projeto e o desenvolvimento de uma família de reatores eletrônicos obtidos através da técnica de integração de conversores estáticos, aplicados à alimentação de lâmpadas fluorescentes sem eletrodos (LFSE). O acionamento deste tipo de lâmpada é realizado a partir de efeitos eletromagnéticos, sem a necessidade de eletrodos. Em virtude disso, as LFSE apresentam, dentre as demais lâmpadas de descarga, uma longa vida útil associada a uma baixa depreciação do fluxo luminoso, representando uma alternativa atraente para sistemas de iluminação. Visando obter circuitos eletrônicos capazes de proporcionar o funcionamento satisfatório da LFSE, faz-se necessário o desenvolvimento de um modelo elétrico capaz de descrever o comportamento da mesma. Tal modelo desenvolvido nesse trabalho contempla, não só o comportamento estático da lâmpada em diferentes pontos de operação, como também suas perdas magnéticas envolvidas. Em virtude das características magnéticas das LFSE, a frequência de operação desse tipo de sistema deve ser elevada, com o objetivo de reduzir o volume dos elementos indutivos, evitando o sombreamento causado pelos mesmos. Com isso, propõem-se um conjunto de sistemas eletrônicos capazes de realizar o acionamento eficiente da lâmpada. O estudo de tais sistemas tem por finalidade estabelecer relações e comparações quanto ao comportamento e as limitações impostas pelos mesmos. Neste trabalho, o controle da potência entregue a lâmpada também foi analisado. No final, os resultados experimentais são apresentados no intuito de validar o projeto desenvolvido.
297

Desenvolvimento de procedimentos analíticos para a determinação de N-acetilcisteína em produtos farmacêuticos. / Development of analytical procedures for determination of n-acetylcysteine in pharmaceutical formulations.

Suarez, Willian Toito 17 February 2005 (has links)
Made available in DSpace on 2016-06-02T20:36:10Z (GMT). No. of bitstreams: 1 1426.pdf: 2212976 bytes, checksum: 075a2ca195e9ee733003690b11772140 (MD5) Previous issue date: 2005-02-17 / Universidade Federal de Sao Carlos / In this dissertation four analytical procedures for the determination of Nacetylcysteine in pharmaceutical formulations are described. The first procedure developed was a flow injection analysis system for turbidimetric determination of Nacetylcysteine employing Ag+ ions in an acid medium as the precipitant reagent. In this system, 250 µL of 0.01 mol L-1 AgNO3 solution and 500 µL of sample solution were inserted simultaneously into a merging zones flow system. After the precipitate formation in a 100 cm coil reactor, the precipitate generated was monitored turbidimetrically at 400 nm. Desionised water flowing intermittently at 6.3 mL min-1 was used to wash out the precipitate during the sampling stage. The analytical curve was linear in the N-acetylcysteine concentration range from 1.0 x 10-4 to 1.0 x 10-3 mol L-1; with a detection limit of 8.0 x 10-5 mol L-1 (3σB/slope) and sampling frequency of 60 h-1 was obtained. The relative standard deviation was smaller than 1% for Nacetylcysteine solutions in the concentrations of 1.0 x 10-4 and 5.0 x 10-4 mol L-1 (n=20). The recoveries obtained for two samples ranged from 104 to 122%. A flow injection system with spectrophotometric detection is proposed for determining Nacetylcysteine in pharmaceutical formulations. In this system, N-acetylcysteine was oxidized by Fe(III) and the Fe(II) produced is spectrophotometrically monitored as Fe(II)-1,10-phenantroline complex at 515 nm. Under the optimum analytical conditions, the linearity of the calibration graph for N-acetylcysteine ranged from 1.8 x 10-5 to 1.5 x 10-4 mol L-1. The detection limit of 6.3 x 10-6 mol L-1 (3σB/slope) and recoveries between 102 to 113 % were obtained. The preparation and electrochemical characterization of a carbon paste electrode modified with copper (II) hexacyanoferrate(III) (CuCHF) as well as its behaviour as electrocatalyst toward the oxidation of N-acetylcysteine were investigated. The electrochemical behaviour of the modified electrode and the electrooxidation of N-acetylcysteine were explored using sweep linear voltammetry. The best voltammetric response was observed for a paste composition of 20%(w/w) copper (II) hexacyanoferrate(III) complex, acetate buffer solution at pH of 6.0 as the electrolyte and scan rate of 10 mV s-1. A linear voltammetric response for N-acetylcysteine was obtained in the concentration range xiv from 1.2 x 10-4 to 8.3 x 10-4 mol L-1, with a detection limit of 6.3 x 10-5 mol L-1 (3σB/slope). The proposed electrode is useful for the quality control and routine analysis of N-acetylcysteine in pharmaceutical formulations. Finally, a simple, precise, rapid and low-cast potentiometric method for N-acetylcysteine determination in pure form and in pharmaceutical preparations is proposed. N-acetylcysteine present in tablets containing known quantity of drug was potentiometrically titrated in aqueous solution with AgNO3. No interferences were observed in the presence of common components of the tablets as saccharin, sucrose and EDTA. The analytical results obtained by applying the proposed method compared very favorably with those obtained by the comparative method. Recovery of N-acetylcysteine from various tablets dosage formulations range from 98.7 to 103.0%. Compared to others procedures reported in the literature the procedures developed in this dissertation shows to be better and cheaper to determination of N-acetylcysteine in pharmaceutical formulations. / Nessa dissertação descreve-se quatro procedimentos analíticos para a determinação de N-acetilcisteína em formulações farmacêuticas. O primeiro procedimento desenvolvido foi um sistema de análise por injeção em fluxo para a determinação turbidimétrica de N-acetilcisteína empregando como reagente precipitante íons Ag+ em meio ácido. Nesse sistema, solução do reagente AgNO3 0,01 mol L-1 e da amostra foram inseridos simultaneamente em zonas coalescentes em volume de 250 e 500 µL, respectivamente. Após a formação do precipitado em uma bobina reacional de 100 cm, o produto gerado foi monitorado turbidimetricamente em 400 nm. Adaptou-se um fluxo intermitente de água desionizada a uma vazão de 6,3 mL min-1 para a limpeza do sistema durante a amostragem. A curva analítica foi linear no intervalo de concentração de Nacetilcisteína de 1,0 x 10-4 a 1,0 x 10-3 mol L-1, com limite de detecção de 8,0 x 10-5 mol L-1 (3σB/inclinação) e freqüência de amostragem de 60 h-1. Os desvios padrões relativos foram menores que 1% para soluções de N-acetilcisteína de 1,0 x 10-4 e 5,0 x 10-4 mol L-1 (n=20). Os valores do teste de recuperação em duas amostras comerciais variaram na faixa de 104 a 122%. Como um segundo procedimento, um sistema de análise por injeção em fluxo com detecção espectrofotométrica foi proposto. Nesse sistema, N-acetilcisteína foi oxidada por Fe(III), sendo o Fe(II) produzido monitorado espectrofotometricamente como Fe(II)-1,10-ortofenantrolina em 515 nm. Sobre as condições analíticas otimizadas, a curva analítica foi linear em um intervalo de concentração de N-acetilcisteína entre 1,8 x 10-5 a 1,5 x 10-4 mol L-1. O limite de detecção obtido foi de 6,3 x 10-6 mol L-1 (3σB/inclinação) e as recuperações variaram na faixa de 102 a 113%. A caracterização e a preparação de um eletrodo de pasta de carbono modificado com hexacianoferrato de cobre(II) (CuHCF) foi investigado. O comportamento eletroquímico do eletrodo modificado para eletrooxidação da N-acetilcisteína foi explorado usando voltametria linear. As melhores respostas voltamétricas foram: composição da pasta de carbono de 20% (m/m) do complexo de hexacianoferrato de cobre(II), solução tampão acetato como xii solução eletrolítica e velocidade de varredura de potenciais de 10 mV s-1. A curva analítica foi linear na região de concentração de N-acetilcisteína entre 1,2 x 10-4 a 8,3 x 10-4 mol L-1, com um limite de detecção de 6,3 x 10-5 mol L-1 (3σB/inclinação). O eletrodo proposto foi usado para o controle e análise de rotinas de formulações farmacêuticas. Finalmente, um método potenciométrico simples, preciso, rápido e de baixo custo foi proposto para a determinação de N-acetilcisteína na forma pura e em formulações farmacêuticas. A N-acetilcisteína presente em formulações farmacêuticas foi determinada potenciometricamente empregando-se como titulante uma solução aquosa de AgNO3. Interferências não foram observadas na presença de componentes comumente encontrados nas formulações farmacêuticas, a saber: sacarina, sacarose e EDTA. Os resultados analíticos obtidos a partir da aplicação do método proposto estão em uma boa concordância com aqueles obtidos pelo método comparativo. A recuperação obtida para a N-acetilcisteína em várias formulações farmacêuticas variou de 98,7 a 103,0%. Em comparação com a maioria dos procedimentos descritos na literatura, os procedimentos desenvolvidos nessa dissertação mostraram-se ser mais baratos e simples para a determinação de Nacetilcisteína em formulações farmacêuticas.
298

Biossegurança no controle da infecção hospitalar: desenvolvimento de imunossensor impedimétrico para detecção de Staphylococcus aureus em áreas críticas hospitalares / Biosafety in the control of hospital infection: development of an impedimetric immunosensor for detection of Staphylococcus aureus in critical areas of hospitals

Fialho, Ana Cristina Vasconcelos 21 October 2011 (has links)
Made available in DSpace on 2016-06-02T19:02:40Z (GMT). No. of bitstreams: 1 3890.pdf: 2739392 bytes, checksum: fdb93cb69cafb89992f3e6a155deacfb (MD5) Previous issue date: 2011-10-21 / The Biosafety is a very important tool for the Control of Hospital Infection establishing through methods, techniques and standards, measures to be adopted in order to prevent and control risks that may contribute to hospital infection. This work reports the development of an impedimetric immunosensor for detection of pathogenic bacteria, specifically Staphylococcus aureus (S. aureus), in hospital critical areas (Surgical Centers and Intensive Care Units) to contribute to the hospital infection control. Different parameters were studied: direct immobilization of protein A of S. aureus on the surface of the transducer or the working electrode (screen-printed electrode - SPE), immobilization of protein A on SPEs modified with self-assembled monolayers (SAMs) of cystamine (CYS) and glutaraldehyde (GA); different incubation times and dilutions were used for both modifiers as for protein A and anti- S. aureus antibodies; blocking with bovine serum albumin (BSA) and immunoassay (antigen-antibody reaction, Ag-Ab). Electrochemical techniques (electrochemical impedance spectroscopy - EIS and cyclic voltammetry - CV) and non electrochemical (microscopy) were used for the characterization and construction of the immunosensor. The impedance measurements and cyclic voltammetry showed the good results with self-assembled monolayer of cystamine 2 x 10-2 mol L-1 and glutaraldehyde 2,5% with incubation periods of 2 and 1h, respectively; immobilization of protein A 1:20 (tincub = 12 h) and anti-S. aureus monoclonal Ab (tincub = 3 h) and step blocking with 0.5% BSA (tincub = 1 h). For the Ag-Ab interaction S. aureus ATCC - 6535 strains (analyte) were used and incubation for 30 min. The immunosensor developed has proven to be an effective method for monitoring of S. aureus in a hospital environment and that can be applied as an indicative tool of the effectiveness of the standards and procedures applied to the control of hospital infection. / A Biossegurança constitui uma ferramenta de grande relevância para o Controle da Infecção Hospitalar estabelecendo através de métodos, técnicas e normas, condutas a serem adotadas com o intuito de prevenir e controlar os riscos que podem favorecer à infecção hospitalar. Este trabalho relata o desenvolvimento de um imunossensor impedimétrico para detecção de Staphylococcus aureus (S. aureus), em áreas críticas hospitalares (Centros Cirúrgicos e Unidades de Terapia Intensiva) visando contribuir para o controle de infecção hospitalar. Diferentes parâmetros foram estudados: imobilização direta da proteína A de S. aureus na superfície do transdutor ou eletrodo de trabalho (screen-printed electrode - SPE); imobilização da proteína A sobre SPEs modificados com monocamadas auto-organizadas (SAMs) de cistamina (CYS) e glutaraldeído (GA); diferentes tempos de incubação e diluições foram utilizados tanto para os modificadores como para a proteína A e anticorpos anti-S. aureus; bloqueio com soroalbumina bovina (SAB) e imunoensaio (reação antígeno-anticorpo, Ag-Ac). Técnicas eletroquímicas (espectroscopia de impedância eletroquímica - EIS e voltametria cíclica - VC) e não eletroquímicas (microscopias) foram utilizadas para a caracterização e construção do imunossensor. As medidas de impedância e voltametria cíclica mostraram bons resultados com monocamadas auto-organizadas de cistamina 2 x 10-2 mol L-1 e glutaraldeído 2,5% com tempos de incubação de 2 e 1 h, respectivamente;assim como as imobilizações da proteína A 1:20 (tincub = 12 h); Ac monoclonais anti-S. aureus (tincub = 3 h) e etapa de bloqueio com SAB 0,5% (tincub = 1 h). Na interação Ag-Ac utilizou-se cepas de S. aureus ATCC - 6535 (analito) e incubação de 30 min. O imunossensor desenvolvido indicou ser um método efetivo para monitoramento de S. aureus em ambiente hospitalar e que pode ser aplicado como instrumento indicativo da efetividade das normas e condutas aplicadas para o controle de infecção hospitalar.
299

Detecção e quantificação eletroquímica de substâncias de interesse clínico, ambiental e forense utilizando eletrodo de pasta de grafite modificado com trisilanol poss ligado a suportes porosos e eletrodos impressos obtidos via screen-printed /

Cumba, Loanda Raquel January 2016 (has links)
Orientador: Devaney Ribeiro do Carmo / Resumo: O presente trabalho descreve a preparação, caracterização e aplicação eletroanalítica de um metalosilsesquioxano ligado em uma sílica mesoporosa (MCM-41) e em uma zeólita (H-FAU-Si/Al 40) com hexacianoferrato de níquel adsorvido em sua superfície. Algumas técnicas espectroscópicas como: Espectroscopia no infravermelho por transformada de Fourier (FTIR), Microscopia eletrônica de varredura (MEV), Espectroscopia por Energia Dispersiva de Raios X (EDS) e Voltametria cíclica, foram utilizadas na caracterização dos materiais formados. Os espectros na região do Infravermelho para o MTTiPNiH e ZTTiPNiH apresentaram as bandas de seus precursores (TTiP, MCM-41 e H-FAU-Si/Al 40), apenas duas absorções diferiram dos demais espectros, uma em, aproximadamente, 2168 cm-1 e outra a 2098 cm-1, tais resultados foram atribuídos ao estiramento ν (C≡N). Para o MTTIPNiH, através das micrografias pode-se observar partículas com tamanhos variados, entre 0,30 µm a 0,60 µm. Para o ZTTiPNiH as micrografias apresentaram um pequeno aumento no tamanho de partículas, aproximadamente de 50 nm, quando comparado a seus precursores. O EDS determinou a composição química semi-quantitativa dos elementos carbono, oxigênio, silício, titânio, fósforo, níquel e ferro, presentes em ambas as amostras. O eletrodo de pasta de grafite exibiu um par redox bem definido com potencial de médio padrão (E°’) de +0,53 V e +0,51 V para o MTTiPNiH e ZTTiPNiH, respectivamente, atribuído ao processo redox FeII(CN)6 / FeIII(CN)6 em... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This research describes the preparation, characterization and electroanalytical application of a metalosilsesquioxane bonded in mesoporous silica (MCM-41) and in zeolite (H-FAU-Si/Al 40) with nickel hexacyanoferrate adsorbed on their surface. Techniques as fourier transform infra-red spectroscopy (FTIR), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS) and cyclic voltammetry were used in the characterization of the synthesized materials. The spectra in the infrared region for MTTiPNiH and ZTTiPNiH showed the bands of their precursors (TTiP, MCM-41 and H-FAU Si/Al 40), only two absorption differed from the others spectra, one at, approximately, 2168 cm-1 and another at 2098 cm-1 , which were attributed to stretching ν(C≡N). For MTTIPNiH through the micrographs can be observed particles with varied sizes between 0.30 µM to 0.60 µm. For ZTTiPNiH the micrographs showed a small increase in particle size, approximately, 50 nm, as compared to their precursors. EDS determined the semi-quantitative chemical composition of carbon, oxygen, silicon, titanium, phosphorus, nickel and iron present in both samples. The carbon paste electrode exhibited a well-defined redox couple with E°' = +0.53 V and +0.51 V for MTTiPNiH and ZTTiPNiH, respectively, attributed to the redox process FeII(CN)6 / FeIII(CN)6 in presence of nickel. Carbon paste electrode modified with MTTiPNiH showed electrocatalytic activity to dipyrone and sulfite. However the carbon paste electrode... (Complete abstract click electronic access below) / Doutor
300

Desenvolvimento e caracterização de filmes de poli(ácidos hidroxifenilacéticos) para aplicação na biodetecção de Neisseria meningitidis e Anaplasma marginale

Rodrigues, Luciano Pereira 08 August 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this study we investigated the electropolymerization isomers hydroxyphenylacetic acid, for their application in the construction of polymeric systems, by immobilizing synthetics molecules for development of biological sensors. The graphite electrodes electrochemically modified were characterized for morphology and electrochemical behavior showing that the poly(2-hydroxyphenylacetic acid), poly(3-hydroxyphenylacetic acid) and poly(4-hydroxyphenylacetic) are electroactive, and the latter showed a lower yield in electrosynthesis in agreement with the images of atomic force microscopy showed that the surface of graphite electrodes were changed less with this material compared to its isomers. The electrochemical impedance spectra of poly (4-hydroxyphenylacetic acid) showed that this material is more resistive with respect to its other isomers which are more conductive in accordance with the values of current and voltage shown by tests ion exchange the probes positive and negative. The ratio between the masses electrodeposited and the loads required to carry out the redox process these materials remained constant demonstrating that the same number of electrons are involved in reduction and oxidation of these materials according to the diagnostic reversibility applied by cyclic voltammetry are unanimously reversible systems, however poly(3-hydroxyphenylacetic acid) was more stable during repeated cycling electrochemically in perchloric acid. The optimized tridimensional structures justify the electrochemical and morphologic behavior of these three platforms, wherein the poly(2-hydroxyphenylacetic acid) and poly(3-hydroxyphenylacetic acid) have structures with a more ordered arrangement, unlike poly(4-hydroxyphenylacetic acid), which has a rather more disordered structure and therefore more resistive, while isomers are more conductors. The mechanistic proposal begins with the anodic oxidation of monomers whose square wave voltammetry experiments showed the loss of an electron. The couplings between cation radicals promote a formation of ether leaving the acetate groups exposed on the structure. The pairing occurs between the phenolic oxygen and carbon of the aromatic ring whose potential were studied by spin density and consistent with the resonance structures of the cation-radical that are in the suggested mechanisms. In tests incorporation of nitrogenous bases found that poly(3-hydroxyphenylacetic acid) also proved more effective in the retention of the same and for this reason associated with their better electrochemical behavior described above, it was selected among others for applying isomers polimeric systems by immobilizing synthetics molecules by physical adsorption. In the first system froze synthetic oligonucleotides that mimic fragments of DNA from the bacterium Neisseria meningitidis able to recognize their genomic DNA in samples of pure cultures by differential pulse voltammetry and electrochemical impedance spectroscopy, and this latter showed a better response sensitivity signal in relation to the increasing concentration of the target. In the second system, there immobilization of synthetic peptides compatible to the cell membrane of Anaplasma marginale able to selectively recognize antibodies in their sera samples from cattle. The images made by atomic force microscopy of the two procedures backing the effective recognition of both polimeric systems developed for the detection of Neisseria meningitidis and Anaplasma marginale bacteria causing bacterial meningitis and bovine anaplasmosis, respectively. / Neste trabalho foi investigada a eletropolimerização dos isômeros do ácido hidroxifenilacético, visando sua aplicação na construção de sistemas poliméricos, através da imobilização de moléculas sintéticas para o desenvolvimento de sensores biológicos. Os eletrodos de grafite eletroquimicamente modificados foram caracterizados quanto à morfologia e o comportamento eletroquímico, evidenciando que o poli(ácido 2-hidroxifenilacético), poli(ácido 3-hidroxifenilacético) e poli(ácido 4-hidroxifenilacético) são eletroativos, sendo que este último apresentou um menor rendimento em massa na eletrossíntese, em concordância com as imagens de microscopia de força atômica, que mostraram que a superfície dos eletrodos de grafite foram menos alteradas com este material em relação aos seus isômeros. Os espectros de impedância eletroquímica do poli(ácido 4-hidroxifenilacético), mostraram que esse material é mais resistivo em relação aos seus outros isômeros que são mais condutores em concordância com os valores de corrente e potencial evidenciados nos ensaios de troca iônica nas sondas positiva e negativa. A relação entre as massas eletrodepositadas e as cargas necessárias para realizar o processo redox nestes materiais foi constante, indicando que o mesmo número de elétrons está envolvido na oxidação e redução destes materiais, que se comportaram como sistemas reversíveis segundo os diagnósticos de reversibilidade aplicados por voltametria cíclica, todavia o poli(ácido 3-hidroxifenilacético) mostrou-se mais estável eletroquimicamente durante sucessivas ciclagens em ácido perclórico. As estruturas tridimensionais otimizadas justificam o comportamento eletroquímico e morfológico destas três plataformas, em que os poli(ácido 2-hidroxifenilacético) e poli(ácido 3-hidroxifenilacético) apresentam estruturas com um arranjo mais ordenado e por isso são mais condutores ao contrário do poli(ácido 4-hidroxifenilacético) que tem uma estrutura mais desordenada, e por isso mais resistiva. A proposta mecanística inicia-se com a eletrooxidação dos monômeros, cujas investigações experimentais por voltametria de onda quadrada, mostraram a perda de um elétron. Os acoplamentos entre os cátions radicais promovem uma formação de éter deixando os grupos acetato expostos na estrutura. O emparelhamento ocorre entre o oxigênio fenólico e carbonos do anel aromático, cujas possibilidades foram estudadas pela densidade de spin e concordantes com as estruturas de ressonância dos cátions-radicais que estão nos mecanismos sugeridos. Nos testes de incorporação de bases nitrogenadas, verificou-se que o poli(ácido 3-hidroxifenilacético) mostrou-se mais eficiente na retenção das mesmas e por este motivo associado ao seu melhor comportamento eletroquímico, foi selecionado dentre os outros isômeros como o sistema polimérico mais adequado para aplicação nas detecções, através da imobilização por adsorção física de moléculas sintéticas de reconhecimento. No primeiro sistema, imobilizou-se oligonucleotídeos sintéticos compatíveis a fragmentos de DNA da bactéria Neisseria meningitidis, capazes de reconhecer seu DNA genômico em amostras por voltametria de pulso diferencial e espectroscopia de impedância eletroquímica, sendo que esta última mostrou uma melhor sensibilidade de resposta de sinal em relação ao aumento de concentração do alvo. No segundo sistema, ocorreu a imobilização de peptídeos sintéticos compatíveis à membrana celular da Anaplasma marginale, capazes de reconhecer seletivamente seus anticorpos em amostras de soros sanguíneos bovinos. As imagens feitas por microscopia de força atômica, respaldam o reconhecimento eficaz de ambos os sistemas poliméricos desenvolvidos para detecção das bactérias Neisseria meningitidis e Anaplasma marginale, causadores de meningite bacteriana e anaplasmose bovina, respectivamente. / Doutor em Química

Page generated in 0.0757 seconds