• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 713
  • 16
  • 12
  • 12
  • 12
  • 10
  • 9
  • 3
  • 1
  • 1
  • Tagged with
  • 734
  • 286
  • 273
  • 196
  • 173
  • 165
  • 152
  • 148
  • 148
  • 141
  • 140
  • 138
  • 121
  • 104
  • 102
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
561

MCML gate design methodology ante the tradeoffs between MCML and CMOS applications / Metodologia de projeto de portas lógicas MCML e a comparação entre portas lógicas CMOS e MCML

Canal, Bruno January 2016 (has links)
Este trabalho propõe uma metodologia de projeto para células digitais MOS Current-Mode Logic (MCML) e faz um estudo da utilização destes circuitos, frente à utilização de células CMOS tradicionais. MCML é um estilo lógico desenvolvido para ser utilizado em circuitos de alta frequência e tem como princípio de funcionamento o direcionamento de uma corrente de polarização através de uma rede diferencial. Na metodologia proposta o dimensionamento inicial da célula lógica é obtido a partir do modelo quadrático de transistores e através de simulações SPICE analisa-se o comportamento da célula e se redimensiona a mesma para obter as especificações desejadas. Esta metodologia considera que todos os pares diferencias da rede de pull-down possuem o mesmo dimensionamento. O objetivo através desta metodologia é encontrar a melhor frequência de operação para uma dada robustez da célula digital. Dimensionamos células lógicas MCML de até três entradas para três tecnologias (XFAB XC06, IBM130 e PTM45). Comparamos os resultados da metodologia proposta com o software comercial de otimização de circuitos, Wicked™, o qual obteve uma resposta de atraso 20% melhor no caso da tecnologia XFAB XC06 e 3% no caso do processo IBM130. Através de simulações de osciladores em anel, demonstramos que a topologia MCML apresenta vantagens sobre as células digitais CMOS estáticas, em relação à dissipação de potência quando utilizada em circuitos de alta frequência e caminhos de baixa profundidade lógica. Também demonstramos, através de divisores de frequência, que estes circuitos quando feitos na topologia MCML podem atingir frequências de operação que em geral são o dobro das apresentadas em circuitos CMOS, além do mais atingem este desempenho com uma dissipação de potência menor que circuitos CMOS. A natureza analógica das células MCML as torna susceptíveis às variações de processo. Variações globais são compensadas pelo aumento dos transistores da PDN, já casos de descasamentos, por não terem um método de compensação, acabam por degradar a confiabilidade do circuito. Na avaliação da área ocupada por célula, a topologia MCML mostrou consumir mais área do que a topologia CMOS. / This work proposes a simulation-based methodology to design MOS Current-Mode Logic (MCML) gates and addresses the tradeoffs of the MCML versus static CMOS circuits. MCML is a design style developed focusing in a high-speed logic circuit. This logic style works with the principle of steering a constant bias current through a fully differential network of input transistors. The proposed methodology uses the quadratic transistor model to find the first design solution, through SPICE simulations, make decisions and resizes the gate to obtain the required solution. The method considers a uniform sizing of the pull-down network transistors. The target solution is the best propagation delay for a predefined gate noise margin. We design MCML gates for three different process technologies (XFAB XC06, IBM130 and PTM45), considering gates up to three inputs. We compare the solutions of the proposed methodology against commercial optimization software, Wicked™, that considers different sizing for PDN differential pairs. The solutions of the software results in a 20% of improvement, when compared to the proposed methodology, in the worst case input delay for the XFAB XC06 technology, and 3% in IBM130. We demonstrate through ring oscillators simulations that MCML gates are better for high speed and small logic path circuits when compared to the CMOS static gates. Moreover, by using MCML frequency dividers we obtained a maximum working frequency that almost doubles the frequency achieved by CMOS frequency dividers, dissipating less power than static CMOS circuits. We demonstrate through a reliability analysis that the analog behavior of MCML gates makes them susceptible to PVT variations. The global variations are compensated by the bias control circuits and with the increase of the PDN transistor width. This procedure compensates the gain loss of these transistors in a worst case variation. In other hand, this increasing degrades the propagation delay of the gates. The MCML gates reliability is heavily affected by the mismatching effects. The difference of the mirrored bias current and the mismatching of the differential pairs and the PUN degrade the design yield. The results of the layout extracted simulations demonstrate that MCML gates performs a better propagation delay performance over gates that depend on complexes pull-up networks in standard CMOS implementation, as well as multi-stages static CMOS gates. Considering the gate layout implementation we demonstrate that the standard structures of pull-up and bias current mirror present in the gate are prejudicial for the MCML gate area.
562

Estruturação e aplicação do método da UEP em uma indústria eletrônica

Cornutti, Geraldine January 2017 (has links)
Atualmente as empresas estão inseridas em um cenário de acirrada competição, onde o consumidor torna-se cada vez mais exigente em termos de qualidade e atendimento. Neste contexto, os preços são ditados pelo mercado, cabendo às empresas adequarem seus custos de produção tornando-os compatíveis com os preços impostos pelo consumidor. Desta forma, o custo torna-se um elemento estratégico para a gestão de negócios, onde o controle dos mesmos é de suma importância para garantir a competitividade e sustentabilidade de uma organização. A escolha de um método de custeio adequado às necessidades da empresa permite identificar o mix ideal de vendas, bem como atuar no aumento da eficiência de produção de produtos menos rentáveis de forma a maximizar o lucro. O objetivo geral deste trabalho é propor e aplicar uma sistemática de custeio voltada para as indústrias eletrônicas, buscando atender às necessidades de gestão que são particulares das mesmas. A partir da aplicação, avaliou-se se as informações geradas são úteis para subsidiar o processo de tomada de decisão bem como a redução da imprecisão no cálculo dos custos de produção. / Nowadays companies are part of a scenario of intense competition, where the consumer becomes more and more demanding in terms of quality and service. In this context, prices are dictated by the market, and it is up to companies to adjust their production costs by making them compatible with the prices imposed by the consumer. Giving that, cost becomes a strategic element for business management, which control is crucial to ensure organizations competitiveness and sustainability. The choice of an appropriate costing method, compatible with the characteristics of the company, allows to maximize profit through the identification of the ideal mix of sales as well as to act on production efficiency improvements of less profitable products. The main goal of this work is to propose and apply a costing system focused on the electronic industry, aiming the improvement of cost management. Based on the new system results it will be able to analyze if the provided information is useful to guide the decision making process as well as the reduction of inaccuracy in the calculation of production costs.
563

Avaliação dos mecanismos de endurecimentoda liga AISI 300M submetida a diferentes ciclos de transformações martensíticas / Evaluation of hardening mechanisms Alloy AISI 300M under different cycles of martensitic transformations

Prado, Camila Cristina Silva do [UNESP] 28 July 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-28. Added 1 bitstream(s) on 2015-09-17T15:45:03Z : No. of bitstreams: 1 000848192.pdf: 8037220 bytes, checksum: 24efc4e89d7adb1282b6442410df4998 (MD5) / O aço AISI 300M, considerado um aço de ultra-alta resistência, foi desenvolvido como uma evolução ao aço SAE 4340, para adquirir melhor tenacidade e soldabilidade em aplicações que exigem melhores propriedades mecânicas e facilidade de têmpera. Sua utilização hoje está voltada para o segmento aeroespacial, sendo empregado em partes do veículo lançador de satélites (VLS), alguns veículos de sondagem que fazem parte do Programa Espacial Brasileiro e na confecção de seus envelopes motores (propulsores). A proposta deste trabalho é atribuir melhores características à utilização deste aço, mediante processos e equipamentos de baixo custo. Para isso foram realizados ciclos de transformações martensíticas com o intuito de refino da microestrutura. Os ciclos de transformações martensíticas foram realizados em fornos resistivos do tipo mufla. Buscando-se a nucleação de novos grãos a cada nova transformação martensítica. Para análise dos resultados obtidos foi utilizada a técnica da microcospia correlativa, que consiste na associação de técnicas de microscopia óptica e eletrônica de varredura com o intuito de investigar um mesmo assunto. Através dessa técnica foi possível caracterizar o material tornando possível a verificação e identificação de estruturas em microscopia óptica. Foram realizados ensaios mecânicos como ensaios de tração, dureza, além de análise microestrutural e difração de raios-x, para uma melhor análise dos resultados. Foi avaliado que a melhor condição para o refino dos grãos por ciclos de transformação martensítica foi para ciclos com o aquecimento até 900°C e têmpera em água / The AISI 300M steel, known as a ultra-high strength steel, was developed as an evolution of the SAE 4340 steel, in order to acquire a better tenacity and weldability in applications that demand better mechanical properties and quenching facility. Nowadays, its use is directed for the aerospace segment, being it applied in satellite launch vehicle (VLS) parts, in some probing vehicles that are part of the Brazilian Space Program and in the production of its propellant envelopes (propellant). The aim of this paper is to attribute better features to the use of this steel, through low cost procedures and equipment. For this purpose, martensitic transformation cycles were made to refine microstructures. The martensitic transformation cycles were made in a resistive mufla oven, aiming at nucleation of new grains in each new martensitic transformation. To analyze the results obtained, a correlative microscopy technique was used, which consists in the association of optical microscopy technique and electronic scanning with the purpose of investigating the same subject. Through this technique it was possible to check and identify the structures in an optical microscopy. Mechanical tests, such as tensile and hardness tests, besides a microstructural analysis and X-ray diffraction, were made in order to improve the results analysis. Cycles with heating to 900ºC and water quenching were considered the best condition of grain refining per martensitic transformation cycle
564

Intoxicação cúprica experimental em ovinos: aspectos clínicos e laboratoriais

Pereira, Wanderson Adriano Biscola [UNESP] 05 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-05Bitstream added on 2014-06-13T19:41:09Z : No. of bitstreams: 1 pereira_wab_dr_jabo.pdf: 854556 bytes, checksum: 9d7af941da3e924cbf09a5ce3f63ef48 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os ovinos possuem tendência a acumular cobre no organismo. Quando a capacidade de armazenagem hepática se esgota, o cobre é liberado para o sangue causando sinais clínicos da intoxicação. Para verificar as alterações presentes na bioquímica sérica, hemograma, morfologia eritrocitária, perfil de proteínas séricas e concentração de cobre sérico, durante as fases pré-hemolítica e hemolítica da intoxicação crônica por cobre, foram utilizados seis ovinos distribuídos aleatoriamente em dois grupos: G-1 (controle) e G-2 (experimentalmente intoxicados). Os três ovinos do G-2, além da dieta diária receberam 3mg de CuSO4. 5H2O/Kg PV, seguido de aumentos semanais de 3mg de CuSO4. 5H2O/ Kg PV na dose diária. Diariamente realizou-se o exame físico dos ovinos de ambos os grupos. Para obtenção do hemograma e dos componentes bioquímicos sanguíneos foram colhidas amostras com antes (M0 – M3), durante (M4) e após (M5 e M6) a crise hemolítica. Foram realizadas necropsias dos ovinos do G-2 que morreram e dos ovinos do G-1, submetidos à eutanásia ao fim do experimento e fragmentos do fígado desses animais foram colhidos para avaliação histopatológica. Durante a fase pré-hemolítica evidenciaram-se poucas alterações, entretanto durante a crise hemolítica os ovinos do G-2 apresentaram anemia macrocítica normocrômica, predomínio de hemácias com morfologia de acantócitos, leucocitose por neutrofilia, elevação nas atividades séricas de AST,GGT, CK e hipercupremia; Os teores séricos de ceruloplasmina apresentaram-se diminuídos e os teores de transferrina, proteína de 35.000 Da e IgG de cadeia leve apresentaramse aumentados no M2; os animais intoxicados apresentaram anorexia, membranas mucosas ictéricas, fezes amolecidas de coloração verde-escura e hemoglobinúria. À necropsia observou-se mucosas, fígado e demais tecidos de coloração amarelada... / Sheep have a tendency to accumulate copper in the body. When the liver storage capacity is exhausted, copper is released into the blood causing clinical signs of poisoning. Six lambs fed a basal diet were randomly assigned to 2 groups: G - 1 (control) and G-2 (experimentally intoxicated). The three sheep of the G-2, were drenched initially with 3 mg of CuSO4. 5H2O/ kg bw daily for a week. Every week an additional dose of 3mg CuSO4. 5H2O/ kg bw was included in the drench until signs of copper poisoning appeared. Every day, the lambs were monitored clinically. before (M0 – M3), during (M4) and after (M5 and M6) to hemolytic crisis, sample blood were obtained for biochemical analysis of AST, GGT and CK, blood count, serum proteins and serum concentration of copper. The lambs of the G-2 that died in the course of the experiment and the lambs of the G-1 euthanized at the end, were necropsied and fragments of liver, were obtained for histopathology. During the pre-hemolytic phase few changes were evidenced, however thought the hemolytic crisis the sheep of the G-2 were presented macrocytic normochromic anemia, a predominance of erythrocytes with acantocytes morphology, leukocytosis by neutrophilia, elevation in serum activities of AST, GGT and CK and hipercupremia; Serum levels of ceruloplasmin was presented reduced and the levels of transferrin, 35,000 of protein and IgG- light chain were increased in M2; the lambs of G-2 exhibited anorexia, jaundiced mucous membranes, soften and dark-green feces and hemoglobinuria. Gross examination of poisoned lambs revealed mucous membranes, liver and other tissues yellowish, dark kidneys and brownish urine. Histopathology of the liver showed megalocitose of hepatocytes, the disorganization of strands of hepatocytes, cholestasis and inflammatory infiltrate lymphocytic peri-portal.
565

Avaliação in vitro da microinfiltração marginal e análise da fenda marginal cervical através da microscopia eletrônica de varredura, em restaurações de classe V de resina composta. Efeito dos sistemas adesivos e técnica de preparo cavitário

Orbegoso Flores, Victor Humberto [UNESP] 07 May 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-05-07Bitstream added on 2014-06-13T19:41:17Z : No. of bitstreams: 1 orbegosoflores_vh_dr_arafo.pdf: 838219 bytes, checksum: 839e8fda83a571e900cce3e586d69abb (MD5) / O objetivo deste trabalho foi avaliar a formação de fendas marginais cervicais através da microscopia eletrônica de varredura, assim como, a microinfiltração marginal em preparos de classe V. foram utilizadas duas técnicas de preparo: P1 utilizando fresa carbide no 245 e P2 que utilizou o jato de ar abrasivo Mach 4.0 (80psi de pressão, 27 æm de tamanho de partícula). O tamanho das cavidades foi padronizado com 1,5 mm de profundidade, 2,0 mm de altura e 3,0 mm de largura. Os materiais utilizados foram: G1 -Optibond solo Plus, G2 - Prime & BondNT e G3 - Scotchbond Multiuso Plus (grupo controle), a resina composta Point 4 utilizada para restaurar as cavidades foi padronizada para todas as restaurações. Foram utilizados 42 dentes molares hígidos divididos em 3 grupos de 14 cada, utilizando a face vestibular e lingual sendo que os preparos mostraram a margem oclusal em esmalte e a margem cervical em cemento/dentina. Após as restaurações serem confeccionadas foram armazenadas em água deionizada durante 24 horas, para posteriormente realizar os procedimentos de acabamento e polimento, a seguir os dentes foram isolados com araldite e esmalte para unha e submetidos a testes de ciclagem térmico (400 ciclos)e imediatamente imersos numa solução de nitrato de prata, durante 2 horas, removidos, lavados e colocados numa solução fotoreveladora durante 16 horas. Nessas condições os dentes foram limpos e seccionados no sentido mésio/distal obtendo duas metades as quais por sua vez foram seccionadas no sentido vestíbulo lingual dividindo as restaurações pela metade. Assim, uma metade da restauração foi avaliada através da lupa esteroscópica para observar a microinfiltração e a outra metade preparada e metalizada para ser avaliada através da microscopia eletrônica de varredura. A análise estatística aplicada aos resultados permite concluir que... . / The aim of this study was to evaluate the formation of cervical gap with SEM, and the marginal microleakage in cavities class V. There were used two techniques for the preparations: P1 using a carbide # 245 and P2 using abrasive air Mach 4.0 (80 psi of preasure, 27nm measurement of the particle). The measurements of the cavities were standardized in 1.5mm of deepness, 2,0mm of highness and 3,0mm of lengthiness. The materials used were: G1 Optibond Solo Plus, G2 Prime & Bond NT and G3 Scotchbond Multiuso Plus (control group), it was used the composite Point 4 as the restorative material for all cavities. Forty-two healthy molars, divided in three groups of 14 each one, were used. Cavities were prepared in the buccal and lingual faces, its occlusal margin was in enamel and its cervical margin was in dentin/cement. After that finishing and polishing was made. Teeth were isolated with analdite and nail varnish and thermocycled (400 times). The preparations were dyed with silver nitrate for two hours. Preparations were stored in a photo developing solution for 16 hours. After that time teeth were cleaned and cut (buccal/lingual) Half of the preparation was observed in a stereoscopic microscope and the other half in a SEM. Results: 1.Preparations with abrasive air had a bigger gap; 2.Adhesive systems do not eliminate the formation of gaps; 3.Best results were found in the group prepared with bur and the adhesive Optibond Solo Plus, with a cervical gap 0,84nm, and in the other hand Scotchbond Multiuso Plus showed marginal gaps of 6,36nm; 4.In the occlusal margin Optibond Solo Plus had more microleakage tha Scotchbond Multiuso Plus and Prime & Bond NT.; 5. In the cervical margin, Optibond Solo Plus had good behavior controlling the marginal microleakage, compared with Scotchbond Multiuso Plus and Prime & Bond that had similar leakage between... (Complete abstract, click electronic address below).
566

Estudo dos estados imune e de portador em marrecos de pequim (Anas platyrhynchos) frente ao vírus da doença de Newcastle

Nishizawa, Márcia [UNESP] 22 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-22Bitstream added on 2014-06-13T18:07:34Z : No. of bitstreams: 1 nishizawa_m_dr_jabo.pdf: 817217 bytes, checksum: c7d2f29bf8d4ac1ee5c3fbc71c4756c1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Parâmetros imunológicos, clínicos, epidemiológicos e patológicos da vacinação em marrecos de Pequim foram avaliados por 3 experimentos. Para tanto, foram utilizadas amostras vacinais Ulster 2C, B1 e LaSota do vírus da doença de Newcastle (VDN). No experimento 1, foram utilizados 120 marrecos de Pequim de 1 dia de idade, distribuídos em 4 tratamentos de 30 animais cada, submetidos a diferentes programas imunoprofiláticos. A resposta imune foi avaliada pelo teste de HI, com posterior desafio frente a estirpe patogênica do VDN, aos 60 dias de vida das aves. Após o desafio, em todos os grupos, procedeu-se o reisolamento de vírus patogênico em embriões SPF. Independente do grupo experimental, sinais clínicos da reação vacinal não foram observados. Os resultados dos títulos de anticorpos (HI) mostraram que os programas imunoprofiláticos ensaiados foram igualmente eficientes no estímulo da resposta imune humoral. Os marrecos de Pequim desafiados mostraram-se refratários à enfermidade clínica com o VDN. Entretanto, ficou caracterizado o estado de portador de VDN nesta espécie decorridos até 30 dias da infecção experimental com este patógeno. Nos grupos vacinados, o reisolamento de vírus patogênico foi nulo, evidenciando -se assim a importância da imunoprofilaxia na supressão do estado de portador de VDN dos marrecos de Pequim. No experimento 2, aves SPF foram colocadas em contato íntimo com marrecos de Pequim inoculados com uma estirpe patogênica do VDN, decorridos cinco e 14 dias... / The clinical, epidemiological, immunological and pathological parameters of vaccination in white Pekin ducks were investigated using 3 experiments. Ulster 2C, B1 and LaSota vaccines strains of the Newcastle disease virus (NDV) were used. In experiment 1, 120 one-day-old white Pekin ducks were used, and divided into 4 different groups with 30 birds per group. They were submitted to different vaccination programs. The immunological responses in these birds were measured by HI test. These birds were also challenged with a pathogenic VDN strain at 60 days of age. After challenge, in all the groups, tracheal and cloacal swabs were collected for re-isolation of the virus in SPF embrionated eggs. Independent of the group, clinical signs of reaction to the vaccine were not observed. The antibody titers (HI) results showed that the immune vaccine programs adopted were equally efficient in stimulating protective levels of humoral immune responses. Challenged white Pekin ducks were refractory to the NDV clinical disease. However, a NDV carrier state was shown in this species until 30 days after experimental infection. The vaccinated groups of white Pekin ducks did not present any virus in the re-isolation of the pathogenic virus. Therefore, these results show the relevance of vaccination in suppressing a NDV carrier state in the white Pekin ducks. In experiment 2, SPF chickens housed with white Pekin ducks which were previously inoculated with a pathogenic NDV strain, developed severe and characteristic NDV lesions and died, after five and 14 days...(Complete abstract, acess undermentioned eletronic address)
567

Ação do laser de Er:YAG e de diodo na adesão de elementos sanguíneos e na morfologia de superfícies radiculares irradiadas. Estudo através de microscopia eletrônica de varredura

Theodoro, Letícia Helena [UNESP] 18 June 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-06-18Bitstream added on 2014-06-13T19:04:26Z : No. of bitstreams: 1 theodoro_lh_dr_arafo.pdf: 4192650 bytes, checksum: 68b3ce4f45242d419b74abad0df09354 (MD5) / O objetivo deste estudo foi avaliar in vitro, a adesão de elementos sanguíneos sobre superfícies radiculares irradiadas com laser de Er:YAG e de Diodo, e a ação destes sobre as superfícies radiculares. Foram obtidas 120 amostras de dentes humanos extraídos por doença periodontal, que foram previamente raspados e aplainados com instrumentos manuais, sendo a seguir divididas aleatoriamente em 6 grupos com 20 amostras cada. O G1 (controle)- não recebeu nenhum tratamento; o G2- recebeu aplicação tópica de EDTA 24%; G3- foi irradiado com laser de Er:YAG com 7,6 J/cm2; o G4- irradiado com laser de Er:YAG com 12,9 J/cm 2; o G5 -irradiado com laser de Diodo com 90 J/cm2 e o G6 - foi irradiado com laser de Diodo com 108 J/cm2. Após a realização dos tratamentos, em 10 amostras de cada grupo foi depositado imediatamente a sua punção, tecido sanguíneo originado da vascularização periférica de humano, sendo que 10 amostras não receberam tal tratamento. Após processamento laboratorial as amostras foram analisadas através de microscopia eletrônica de varredura. As fotomicrografias obtidas foram avaliadas através de dois índices: adesão de elementos sanguineos e de morfologia da superfície radicular e estatisticamente analisadas (Kruskall Wallis e Mann-Whitney). Os resultados demonstraram que em relação a adesão de elementos sanguíneos não houve diferenças estatisticamente significante entre o grupo controle e os tratados com o laser de Er:YAG (p=0,7733 e 0,7831) ; O G5 mostrou-se menos efetivo que o controle na adesão de elementos sanguíneos ( p=0,0305 ) e o G2 foi o menos efetivo de todos na adesão. Com relação a morfologia da superfície radicular houve diferenças significantes entre o controle e os grupos do laser de Er:YAG (p= 0,0001) e entre o G5 do Diodo (0,0259); entre o EDTA e os grupos do laser de Er:YAG (p=0,0150 ) e entre o... . / The aim of this study was to evaluate in vitro the adhesion of blood components on root surfaces irradiated with Er:YAG and Diode lasers and these lasers effects on root surfaces. It was obtained 120 samples of human teeth extracted by periodontal disease. They were planed and scaled previously with manual instruments and randomly divided into 06 groups of 20 samples each. The groups were treated according to the following procedures: G1 (Control Group) -received no treatment; G2- had a topical application of EDTA 24%; G3- was irradiated with Er:YAG laser (7,6 J/cmø); G4 - was irradiated with Er:YAG laser (12,9 J/cmø); G5 - was irradiated with Diode laser (90 J/cmø) and G6 was irradiated with Diode laser (108 J/cmø). After these treatments were conducted, 10 samples of each group received a stippler, a blood tissue originated from peripheral vascularization, and the reminiscent samples did not receive such treatment. After laboratorial analysis the samples were analyzed through a scanning electronic microscopy. The photomicrographs obtained were evaluated according to adhesion of blood components and morphology of root surface; and statistically analyzed (Kruskall Wallis and Mann-Whitney). With relation to the adhesion of blood components, the results have shown that there were no significant differences between the Control Group and the groups treated with Er:YAG laser (p=0,7733 and 0,7831); G5 was less effective than the Control Group in adhesion of blood components (p=0,0305) and G2 was the least effective of all groups in this case. With relation to the morphology of root surface there were significant differences among the Control Group, the Er:YAG laser groups (p=0,0001) and the Diode laser G5 (p=0,0259); between the EDTA and the Er:YAG laser groups (p=0,0150) and also between the Diode laser G6 and the Er:YAG laser groups (p=0,0032)... (Complete abstract, click electronic address below).
568

Espectros de raios-x em MEV indicam associação entre Al e Si em plantas acumuladoras de Al do Cerrado

Bressan, Anna Carolina Gressler [UNESP] 28 March 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-28Bitstream added on 2014-08-13T18:01:26Z : No. of bitstreams: 1 000765379.pdf: 1983514 bytes, checksum: 9d6fa551e175e088411c3d7822770964 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Plantas acumuladoras de alumínio (Al) estão distribuídas ao redor do mundo, mas no Cerrado, ou savana brasileira, existem espécies hiper-acumuladoras sendo algumas até mesmo dependentes da presença do Al no solo. Descrevemos padrões anatômicos de armazenamento de Al nos tecidos foliares de espécies acumuladoras e não acumuladoras de Al, empregando diferentes corantes, específicos na detecção deste elemento em tecidos. Em adição, medimos o espectro de raios – x específico para Al em regiões diferentes dos tecidos das folhas, analisados através de microscopia eletrônica de varredura (MEV). Seções transversais da nervura central de folhas de plantas adultas acumuladoras, Miconia albicans, M. rubiginosa (Melastomataceae), Qualea grandiflora, Q. parviflora (Vochysiaceae) e não acumuladoras Styrax ferrugineus e S. camporum (Styracaceae) foram coradas com hematoxilina ou cromo azurol S e visualizadas em microscopia de luz. Análises em MEV e espectros de raios-x foram usados para identificar locais de deposição de Al. Cromo azurol S demonstrou ser um corante específico para Al mais nítido e contrastante em relação à hematoxilina. Confirmamos que os principais locais de acúmulo de Al são paredes celulares de tecidos não lignificados. Observou-se também a presença de grânulos, com alta concentração de Al, confinados em cavidades no parênquima cortical de uma espécie acumuladora. A descrição anatômica da deposição do Al nas folhas e o padrão consistente de o Al estar associado a paredes celulares sugere um papel mais estrutural do que fisiológico para o Al em folhas de plantas lenhosas do Cerrado / Aluminum (Al) accumulator plants are distributed all over the world, but in the Brazilian savanna or Cerrado there are hyper accumulator species, and some are Aldependent. We described anatomical patterns of Al storage in leaf tissues of Alaccumulators and non-accumulators using different Al-specific dyes. In addition, we measured Al-specific x-ray spectra from different regions in leaf tissues analyzed by scanning electron microscopy (SEM). Cross sections from leaves of adult plants from the Al-accumulators, Miconia albicans, M. rubiginosa (Melastomataceae), Qualea grandiflora, Q. parviflora (Vochysiaceae), and the non-accumulators Styrax ferrugineus and S. camporum (Styracaceae) were stained with hematoxylin and chrome azurol S for light microscopy. SEM analyses and x-ray spectra were used to identify sites of Al accumulation in leaves. Chrome azurol S was demonstrated to be a sharper and more contrasting Al-specific dye in relation to hematoxylin. We confirmed that the main sites for Al accumulation are cell walls of non-lignified leaf tissues of Al-accumulating plants. In these plants, we also observed Al-constitutive granules confined in cavities formed in the cortical parenchyma. The anatomical description of Al accumulation in leaves and the consistent pattern of Al association with cell walls strongly suggest structural rather than physiological roles of Al in leaves of Cerrado woody plants
569

Um sistema eletrônico de 2kW para emulação/simulação experimental da característica estática de saída, tensão (versus) corrente, de sistemas de geração com células combustível tipo PEM /

Melo, Guilherme de Azevedo e. January 2007 (has links)
Orientador: Carlos Alberto Canesin / Banca: Fabio Toshiaki Wakabayashi / Banca: Luiz Carlos de Freitas / Resumo: Este trabalho apresenta o desenvolvimento e implementação de um emulador para a característica estática de saída (Tensão versus Corrente) equivalente àquela de fontes de energia com células combustível. O emulador apresenta como vantagens, em relação à aquisição de uma FC, o baixo custo, o reduzido espaço físico e a flexibilidade via software para a implementação de diversas características baseadas em diferentes tipos de células combustível. Neste sentido, o emulador proposto permite a realização de ensaios preliminares durante a fase de projeto e os testes dinâmicos dos subsistemas de condicionamento de energia, sem a necessidade do acoplamento com o sistema de geração à células combustível, reduzindo-se os custos associados a estes testes laboratoriais. O emulador proposto consiste em um conversor Buck isolado "Full-Bridge", com potência de saída de 2kW e alimentação via barramento de 400VCC, permitindo a emulação da característica nominal de saída de um conjunto de células tipo PEM ("Proton Exchange Membrane" - Membrana de Troca Protônica), em uma faixa de tensão de saída variando entre 32VCC e 72VCC, dependendo da corrente drenada pela carga. O circuito principal de controle é realizado através... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a design and implementation of an emulator to the static output characteristic (Voltage versus Current) that is similar to Fuel Cell generators. There are many advantages on using the Fuel Cell emulator. The emulator is cheaper, smaller and more flexible than the real Fuel Cell systems, because it is possible to emulate different characteristics through the use of a computer. In this context, a Fuel Cell emulator is proposed in this work in order to allow laboratory testes in the power conditioning system during its design and development stage. The proposed emulator is an insulated "Full-Bridge" converter with "Buck" operation, 2kW output power and 400VCC input voltage. This emulator achieves the output characteristic of a PEM (Proton Exchange Membrane) Fuel Cell stack with output voltage range of 32VCC to 72VCC, depending on the output current. The main control circuit is based on FPGA (Field Programmable Gate Array) and VHDL (Very High Speed Integrated Circuit Hardware Description Language) language. The experimental results demonstrate that the proposed emulator achieves the output static characteristic of the PEMFC Fuel Cell System and this output characteristic can be easily modified in order to obtain another desirable static... (Complete abstract click electronic access below) / Mestre
570

Estudo do comportamento eletromiográfico do masseter e temporal após o tratamento da mordida cruzada posterior funcional com o aparelho quadrihélice

Santos, José Ricardo Prando dos [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:56:45Z : No. of bitstreams: 1 santos_jrp_me_araca.pdf: 407793 bytes, checksum: 3faf7f15cedfc7025c0f5d9686f97b5b (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo deste estudo foi avaliar a atividade eletromiográfica dos músculos masseter e temporal anterior em crianças com mordida cruzada posterior unilateral funcional. A amostra foi composta por 8 crianças com idade de 5 a 10 anos, um menino e sete meninas que não apresentavam hábitos parafuncionais, sintomas neuromusculares como dor ou fadiga e disfunção temporomandibular. As análises eletromiográficas foram realizadas nestes músculos na posição de repouso, máximo apertamento dentário na posição de máxima intercuspidação e durante a mastigação no lado da mordida cruzada e no lado não cruzado, antes (T1) e após (T2) o tratamento da mordida cruzada posterior unilateral funcional com a utilização do aparelho ortodôntico quadrihélice. Os resultados mostraram uma diferença significante somente para o músculo temporal anterior do lado da mordida cruzada para a posição de repouso, mas houve uma tendência para um aumento no temporal anterior do lado não cruzado e para o masseter do lado cruzado, enquanto houve uma diminuição no masseter do lado não cruzado. Durante o apertamento dentário na posição de máxima intercuspidação, todos os músculos monstraram uma tendência ao aumento da atividade eletromiográfica. Durante a mastigação, houve uma tendência para diminuir a atividade em todos os músculos, exceto para o temporal anterior do lado da mordida cruzada, que registrou um aumento. / The purpose of this study was to evaluate the electromyographic activity of masseter and anterior temporal muscles in children with unilateral functional posterior crossbite. The sample was compounded of 8 children aged 5 to 10 years, one boy and seven girls that not present parafunctional habits, neuromuscular symptoms referring to pain or fadigue and temporomandibular disfunction. Electromyographic evaluations were carried out in these muscles at rest position, maximal bite in the intercuspal position and during chewing on the crossbite side and on the noncrossbite side, before (T1) and after (T2) unilateral functional posterior crossbite treatment by using quadhelix orthodontic appliance. The results showed significant difference only for anterior temporal muscle on the crossbite side at rest position, but there was tendency to increase in the anterior temporal on the noncrossbite side and in the masseter on the crossbite side, while there was a decrease in masseter on the noncrossbite side. During maximal bite in the intercuspal position before treatment, all muscles showed a tendency to increase the electromyograpihc activity. During chewing, there was a tendency for decrease activity in all muscles, except for anterior temporal on the crossbite side, that registered an increase.

Page generated in 0.0455 seconds