• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 856
  • Tagged with
  • 856
  • 856
  • 684
  • 564
  • 240
  • 224
  • 217
  • 180
  • 179
  • 166
  • 143
  • 135
  • 120
  • 103
  • 101
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Gerenciamento ambiental de postos de serviço automotivos

Manzochi, Clarice Ilse Schwarz January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-18T10:05:18Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T20:57:29Z : No. of bitstreams: 1 181089.pdf: 20410516 bytes, checksum: 526ad67d54dbf095dd69990594ee648a (MD5) / A incidência de acidentes devido ao transporte e manejo impróprio de combustíveis vem atingindo índices preocupantes, decorrendo em contaminações da atmosfera, solos, cursos d'água, lençóis freáticos e orla marítima, além de apresentarem riscos elevados para a ocorrência de incêndios e de explosões. Este trabalho consistiu no desenvolvimento de uma análise das normas e legislações pertinentes ao Gerenciamento Ambiental de Postos de Gasolina, verificando-se as condições e os resultados reais de suas implementações frente aos demais fatores intervenientes, procurando-se propostas para uma otimização gerencial de postos de serviço, sob o aspecto ambiental. Apesar da existência de diversas normas e leis, poucos são os postos de serviço que possuem um Plano Gerencial realmente implementado. Somando-se a isto, constatado o derramamento de combustível, as alternativas de remediação de locais contaminados, destacando-se os casos em que a água subterrânea é atingida, revelam-se onerosas e muitas vezes com eficiência limitada. A incorporação da análise de risco na revisão dos padrões ambientais a serem atingidos surge como uma alternativa para diminuir os impactos decorrentes da limitação tecnológica e dos altos custos de remediação. Após a análise das legislações, selecionou-se o Posto Cidade Jardim localizado na cidade de Florianópolis, nas proximidades do Mangue do Saco Grande para a elaboração de um Estudo de Caso. Neste estabelecimento, a adequação dos equipamentos e procedimentos operacionais de segurança foi verificada, e o ocorrência de um vazamento fictício de combustíveis foi simulada por modelo matemático, possibilitando a elaboração de uma análise de risco de um acidente envolvendo a contaminação com hidrocarbonetos de petróleo em local de grande fragilidade ambiental. As simulações efetuadas com o modelo BIOSCREEN indicaram que os pontos críticos de exposição, materializados pelas valas de drenagem que conduzem as águas pluviais em direção ao Mangue do Saco Grande, deverão ser atingidas em aproximadamente 1 ano após a ocorrência de um acidente, oferecendo tempo hábil para a adoção de medidas de intervenção. Entretanto, o Posto Cidade Jardim não reflete a realidade dos Postos de Serviço no Brasil, cujo cenário real deverá ser retratado após o cadastramento preconizado pela Resolução CONAMA nº 263/2000. Os dados a serem obtidos a partir desta Resolução devem ser adequadamente tratados, dentro de uma perspectiva de análise de risco integrada para que não sirvam apenas como instrumento burocrático de liberação de licenças ambientais, mas que possam realmente ser utilizados como ferramenta para tomada de decisão frente a ocorrência de acidentes.
382

Utilização de reator de leito fluidizado trifásico aeróbio em sistema de tratamento combinado de águas residuárias

Campos, Rosane Hein de January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-18T11:51:02Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T00:06:49Z : No. of bitstreams: 1 182904.pdf: 26947699 bytes, checksum: 188065ff59b00e574141746a1e317ff0 (MD5) / Neste trabalho, foram desenvolvidos estudos em um sistema de tratamento combinando reator anaeróbio (tanque séptico) com reator aeróbio (leito fluidizado trifásico), tendo como objetivo avaliar o comportamento do reator aeróbio no tratamento de esgoto sanitário e do restaurante universitário (RU), da UFSC. Utilizou-se um reator de leito fluidizado trifásico aeróbio com volume de 62,80 L e foram testados dois tipos de materiais suportes, o poliestireno e o PVC, com densidades de 1065 kg/m3 e 1329 kg/m3 e diâmetro médio de 2,7 mm e 4,02 mm, respectivamente. Trabalhou-se em duas etapas. Na primeira etapa, foram realizados estudos hidrodinâmicos do reator e o tratamento biológico, com efluente doméstico do RU, utilizando o poliestireno como material suporte. A segunda etapa consistiu de estudos hidrodinâmicos do reator e o tratamento biológico, com efluentes domésticos do RU e esgoto urbano, utilizando o PVC como material suporte. O acompanhamento analítico do controle do processo foi efetuado pelos seguintes parâmetros: pH, temperatura, oxigênio dissolvido, sólidos suspensos, produção de lodo, polissacarídeos (PS) aderidos ao suporte e suspensos no efluente e proteínas (PN) aderidas ao suporte e suspensas no efluente. Os resultados mostraram que o poliestireno não se apresentou como uma boa alternativa para o tratamento biológico, para as condições operacionais utilizadas. Com a utilização do PVC, obtiveram-se eficiências médias de remoção de DQO filtrada, foram de 36% e 78% para cargas orgânicas volumétricas aplicadas (COVap.) de 17 kgDQO/m3d e 36 kgDQO/m3d, respectivamente. Observações feitas através do microscópio eletrônico de varredura mostraram um biofilme fino, com colonização no interior da matriz polissacarídica. A relação PS/PN aderida (entre 2,7 e 16,7) indicou a existência de um biofilme mais coeso e como conseqüência baixa produção específica de lodo (1,45 mg de biomassa/mg de DQO removida e 0,19 mg de biomassa/mg de DQO removida). O acompanhamento através do microscópio ótico revelou as condições microbiológicas do efluente. Observaram-se pequenos flocos ricos em Zoogleas, Zooflagelados, Ciliados fixos (Epystilis, Vorticellas) e livres (Uronemas, Metopus e outros), bactérias filamentosas e bactérias livres em suspensão. O coeficiente de desprendimento (bs), mostrou-se elevado, indicando um grande desprendimento do biofilme em meio líquido, devido ao cisalhamento pela passagem do líquido no reator, influenciando na concentração de sólidos suspensos na saída do reator. A combinação de reatores anaeróbios e reator de leito fluidizado trifásico aeróbio apresenta-se como uma alternativa interessante pela eficiência de remoção da matéria carbonácea, aplicando-se elevadas cargas volumétricas orgânicas (>10kgDQO/m3.dia).
383

Coleta de resíduos sólidos domiciliares em local de entrega obrigatória: aspectos de custos e opinião dos usuários.

Souza, Edson Marcondes de 30 November 2005 (has links)
Made available in DSpace on 2016-06-02T20:00:14Z (GMT). No. of bitstreams: 1 DissEMS.pdf: 2946767 bytes, checksum: 0c7cd953c849c0ed69dae475e18c7bfe (MD5) Previous issue date: 2005-11-30 / This work presents a comparison between conventional solid waste collection, also known as door to-door collection which is used by most of the Brazilian s municipalities and the Mandatory Drop-Off Waste Collection At Specific Sites (CLEO), to where the residents must transport their domestic solid waste to be collected. Literature points to the Mandatory Drop-Off (CLEO) as likely to have the lowest cost in the solid waste system. Also, the paper proposes to compare this type of collection with the door-to-door collection. And in addition, to find out the residents opinion about this type of collection, a survey was conducted with the residents of a street segment in Bebedouro-SP, where a drop-off collection is currently made at specific sites, but not in a mandatory way. The survey points that the collection at specific points is 10 to 30 per cent less expensive than the door-to-door collection. (If crew and vehicles are taken in consideration) Bebedouro/SP s survey shows that 75% of respondents are involved and know about the collection of solid waste services. Most of residents that live around main street approved the way that collection and disposal are made, at a central island. However, 60% do not want a container in the curbside of their front house. Another important issue that the respondents declared is their disposition to make a certain sacrifice , like to walk a lot a distance to dispose their solid waste in order to pay their Town s taxes at a discount rate. / Neste trabalho é apresentada uma comparação entre a coleta convencional de resíduos sólidos domiciliares, denominada porta-a-porta, realizada na maioria dos municípios brasileiros e a coleta em locais de entrega obrigatória (CLEO), realizada em pontos específicos, para onde os residentes devem levar os resíduos por eles gerados para serem recolhidos. A literatura aponta este segundo tipo de coleta como o de menor custo no sistema de resíduos sólidos e, neste trabalho buscou-se compara-la com a coleta porta-a porta e conhecer as opiniões a respeito deste tipo de coleta, através de pesquisa com residentes num setor onde é realizada de modo não obrigatório, na cidade de Bebedouro SP. A comparação teórica baseada no modelo de Aguiar (1993) apontou que a coleta em locais de entrega obrigatória pode ser de custo menor que a coleta porta-a-porta em cerca de 10 a 30%, considerando-se a redução de frota e de guarnição. A pesquisa informou que 75% dos respondentes acham-se envolvidos e conhecem os serviços de coleta dos RSD e a maioria aprova o modo como se dispõe e se coleta o lixo, nas lixeiras da ilha central, mas 60% não admitiram ter uma lixeira coletiva na calçada de sua casa. Outro dado importante observado é que a população pesquisada aceita trocar certo sacrifício de sua parte (no caso andar uma distância maior para dispor o lixo) por um benefício concedido pelo poder público (desconto nos tributos municipais).
384

Estudo de um método de priorização de resíduos industriais para subsídio à minimização de resíduos químicos de laboratórios de universidades.

Souza, Karina Elias de 28 February 2005 (has links)
Made available in DSpace on 2016-06-02T20:00:54Z (GMT). No. of bitstreams: 1 DissKES.pdf: 879729 bytes, checksum: 2dcd7a8440cd57e6f8cdff1aae4b8311 (MD5) Previous issue date: 2005-02-28 / The majority of the Brazilian universities don t have systematic waste minimization program, especially for chemical laboratory wastes. However, the industries, due to legal responsibilities, economical factors and in order to use waste management as marketing, have been developed waste minimization procedures. This work presents a study of waste prioritization methods to be minimized and applied a industrial method and mathematical model developed by CERCAL (2000), which was adapted to teaching and research chemical laboratories waste of the Chemical Department (DQ) of Universidade Federal de São Carlos. The CERCAL s method covers three type of analysis: economical value, risk and waste minimization capacity. The economical value analysis won t be applied because the University doesn t have cost/benefit control sufficient for the application. The other two analysis were applied using questionnaire answered by technicians, teachers and researchers, where were determined the waste risk and minimization capacity and consequently, its prioritization. Thirteen DQ s laboratories were researched resulting in 107 answers, each one corresponding to one research or teach practice breeder of waste. The wastes were identified and grouped following the place they came from and its chemical likeness, in 27 groups. Among the 27 groups, 12 were classified by the application of the CERCAL s method as essentially priority to be minimized. / A grande maioria das universidades brasileiras não tem programas sistemáticos de minimização de seus resíduos, principalmente resíduos de laboratórios químicos. No entanto, as indústrias, por responsabilidades legais, por fatores econômicos e para utilizar como seu marketing, têm desenvolvido cada dia mais, técnicas de minimização de resíduos. Este trabalho fez um estudo de métodos de priorização de resíduos a serem minimizados e aplicou um método e modelo matemático de priorização de minimização de resíduos industriais desenvolvido por CERCAL (2000), os quais foram adaptados para os resíduos dos laboratórios químicos de ensino e pesquisa do Departamento de Química (DQ) da Universidade Federal de São Carlos. O método de CERCAL abrange três tipos de análises: análise do resíduo por valor econômico; análise por risco ambiental/saúde humana e análise por facilidade de minimização. A análise por valor não pode ser aplicada na Universidade devido a dificuldades de obtenção de dados de custos e valor de produtos e resíduos. Já as outras duas análises foram aplicadas sobre questionários respondidos por técnicos, docentes e pesquisadores, a partir dos quais puderam ser determinados o risco e a facilidade de minimização dos resíduos e consequentemente, a sua priorização. Foram pesquisados treze laboratórios do DQ, resultando em 107 questionários respondidos, cada um correspondente a uma prática de ensino ou pesquisa geradora de resíduos. Os resíduos foram identificados e agrupados, segundo seu local de geração e suas semelhanças químicas, em 27 grupos. Destes, 12 grupos foram classificados através da aplicação do método de CERCAL como essencialmente prioritários para fins de minimização.
385

Fatores ambientais que afetam a distribuição e estrutura populacional de bivalves límnicos em lagoas adjacentes ao Rio Cuiabá

Michiura, Anderson Wakinaguni 27 February 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-03-13T15:32:07Z No. of bitstreams: 1 DISS_2015_Anderson Wakinaguni Michiura.pdf: 703669 bytes, checksum: 60597a6b6125e23795b4c0739d397627 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-03-14T15:58:39Z (GMT) No. of bitstreams: 1 DISS_2015_Anderson Wakinaguni Michiura.pdf: 703669 bytes, checksum: 60597a6b6125e23795b4c0739d397627 (MD5) / Made available in DSpace on 2017-03-14T15:58:39Z (GMT). No. of bitstreams: 1 DISS_2015_Anderson Wakinaguni Michiura.pdf: 703669 bytes, checksum: 60597a6b6125e23795b4c0739d397627 (MD5) Previous issue date: 2015-02-27 / CAPES / Os bivalves de água doce são um grupo com alto risco de extinção devido às mudanças climáticas, expansão urbana, construção de reservatórios hidrelétricos, crescimento populacional, eutrofização, degradação dos habitats, poluição pontual e difusa dos ecossistemas aquáticos. O objetivo deste trabalho foi identificar quais fatores físicos e químicos da água e sedimento que determinam a estrutura da comunidade de bivalves em 18 lagoas adjacentes ao rio Cuiabá, nos ambientes urbanos e não urbanos. A amostragem dos bivalves foi realizada pelo tateio no fundo das lagoas e por coleta de sedimentos ao longo do transecto com auxílio de uma peneira. Variáveis físicas e químicas da água e % de matéria orgânica do sedimento foram mensuradas e usadas como preditoras da abundância e estrutura da comunidade de bivalves pela ordenação da análise de componentes principais, regressão multivariada e análise de redundância (RDA). A RDA demonstrou uma relação das concentrações de nitrato e % de matéria orgânica com a estrutura da comunidade de bivalves. As espécies encontradas foram A. trapesialis (50,66%), Pisidium sp. (26,98%), C. fluminea (7,48%), C. inflata (6,82%) e A. elongatus (6,16%). As populações de A. trapesialis e A. elongatus estiveram relacionadas positiva e significativa com o nitrato. O aumento da % de matéria orgânica no sedimento esteve relacionado com menor abundância de A. elongatus, entretanto pouca relação com a classe de comprimento das valves. A espécie A. trapesialis teve efeito positivo e significativo com a variável oxigênio dissolvido em relação à classe de comprimento das valves. Os fatores ambientais que refletem os nutrientes podem influenciar na distribuição da comunidade de bivalves de água doce, no entanto, não determinam a estrutura da comunidade em lagoas urbanas e não urbanas. / Freshwater mussels are a group at high risk of extinction due to climate change, urban expansion, construction of hydroelectric reservoirs, population growth, eutrophication, habitat degradation, pollution and diffuse spot of aquatic ecosystems. This works was to identify which physical and chemical factors of the water and sediment that determine the structure of mussels community in 18 of ponds the Cuiaba river, in urban and non-urban environments. Sampling of mussels was conducted by groping the bottom of ponds and collecting sediment along transect with the aid of a sieve. The physical and chemical water variables and % organic matter in the sediment were measured and used as predictors of abundance and structure of the mussel community by ordering the principal component analysis, multivariate regression and redundancy analysis (RDA). The RDA showed a ratio of nitrate concentrations and % organic matter having the structure of mussels community. The species were A. trapesialis (50,66%), Pisidium sp. (26.98%) C. fluminea (7,48%), C. inflata (6,82%) and A. elongatus (6,16%). Populations of A. trapesialis and A. elongatus were positively and significantly related to nitrate. Increased % of organic matter in the sediment was associated with a lower abundance of A. elongatus, however little to do with the length class of valves. The species A. trapesialis had a positive and significant effect on the variable dissolved oxygen relative to the valves length class. Environmental factors that reflect the nutrients may influence the distribution of freshwater mussels community, however, not determine the community structure in urban and non-urban environments.
386

Densidade e caracterização genotípica de comunidades bacterianas em área suscetível a contaminação por hidrocarbonetos de petróleo na Amazônia Meridional, Mato Grosso, Brasil

Oliveira, Andrea Ferreira de 18 December 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-03-14T14:40:28Z No. of bitstreams: 1 DISS_2015_Andrea Ferreira de Oliveira.pdf: 1343240 bytes, checksum: f3c795b84863003dd18f3429beee0ae5 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-03-14T16:01:26Z (GMT) No. of bitstreams: 1 DISS_2015_Andrea Ferreira de Oliveira.pdf: 1343240 bytes, checksum: f3c795b84863003dd18f3429beee0ae5 (MD5) / Made available in DSpace on 2017-03-14T16:01:26Z (GMT). No. of bitstreams: 1 DISS_2015_Andrea Ferreira de Oliveira.pdf: 1343240 bytes, checksum: f3c795b84863003dd18f3429beee0ae5 (MD5) Previous issue date: 2015-12-18 / CAPES / A elevada manipulação, distribuição e armazenamento dos combustíveis e seus compostos, como os hidrocarbonetos de petróleo, aumenta a probabilidade de acidentes ambientais podendo causar contaminação de solo e fontes de abastecimento público, tais como as águas subterrâneas. Atualmente, a biorremediação destaca-se como uma das técnicas mais utilizadas para recuperação ambiental, empregando bactérias na degradação dos compostos contaminantes. A pesquisa foi realizada em Alta Floresta – MT, e dividida em dois trabalhos. O primeiro verificou se os hidrocarbonetos de petróleo interferem na densidade populacional das comunidades bacterianas de ambientes contaminados nos períodos sazonais de seca e cheia, e o segundo analisou a similaridade bacteriana entre dois poços de monitoramento contaminados. Foram coletadas amostras de água subterrânea e solo do local contaminado utilizando bailers e frascos de plástico estéreis, as amostras foram acondicionadas e transportadas refrigeradas de acordo com técnicas padronizadas. No primeiro trabalho foi avaliada a área contaminada em Alta Floresta, BTEX, variáveis ambientais, e densidade bacteriana de coliformes totais, Escherichia coli, bactérias heterotróficas totais (BHT) e bactérias degradadoras de hidrocarbonetos de petróleo. O levantamento para determinação das áreas contaminadas foi realizado na SEMA-MT, sendo que para os BTEX foi utilizado cromatógrafo a gás, detector de massas e injetor. A sonda multiparâmetros, por sua vez, foi usada para aferir as variáveis ambientais enquanto que as técnicas convencionais de microbiologia foram utilizadas para determinar as densidades bacterianas. No segundo trabalho foram analisadas as variáveis ambientais, BTEX, densidade e diversidade de bactérias degradadoras de hidrocarbonetos, tendo sido utilizada sonda multiparâmetros para as variáveis ambientais, cromatógrafo a gás, detector de massas e injetor para os BTEX, além de técnicas de microbiologia convencional para determinar a densidade bacteriana e técnicas moleculares (BOX-PCR e aplicativo Bionumerics 7.1) para determinar a diversidade. A pesquisa feita no primeiro trabalho confirmou que na cidade de Alta Floresta constava apenas dois postos de combustíveis contaminados (dados da Secretaria Estadual de Meio Ambiente), e as análises realizadas na área de estudo constatou contaminação por BTEX no posto onde o estudo foi realizado, sendo que em alguns pontos o valor encontrado foi elevado como no PM2 apresentou 597,05 μg/L. Durante a primeira coleta, os resultados mais elevados para as variáveis ambientais foram de 6,87 para pH, 29,7 °C de temperatura, 6,96 mg/L de oxigênio dissolvido e 604 mS/m de condutividade elétrica. O PM4 foi o que apresentou maior densidade de coliformes totais (5,95 Log NMP/100 mL) durante a segunda coleta e ausência de E. coli durante ambos os períodos. Para o solo, o ponto com maior densidade de BHT foi o S8 com 5,92 Log UFC/g e para água foi no PM4, durante a primeira coleta com 4,30 Log UFC/mL. A densidade das bactérias degradadoras de hidrocarbonetos foi mais elevada no PM4 (3,68 Log UFC/mL) na primeira coleta. No segundo trabalho o ponto mais contaminado foi o PM1, sendo que o Tolueno foi o composto mais encontrado (267,08 μg/L), a densidade mais elevada das bactérias degradadoras de petróleo, por sua vez, foi no PM2 com 4,05 Log UFC/mL. A diversidade foi maior no PM1, sendo que apenas 20% das linhagens apresentaram similaridade de 100%. De forma geral os postos de combustíveis são áreas suscetíveis a contaminação, os BTEX e as variáveis ambientais podem alterar a densidade e diversidade das comunidades bacterianas do local contaminado. Com os resultados encontrados na pesquisa observa-se que a contaminação no local ocorre de forma difusa e que a hipótese de biorremediação na área não pode ser descartada. / The high handling, distribution and storage of fuels and their compounds such as petroleum hydrocarbons, increases the likelihood of environmental accidents may cause soil contamination and public sources of supply, such as groundwater. Currently, bioremediation stands out as one of the most widely used techniques for environmental restoration, using bacteria in degradation of the contaminating compounds. The survey was conducted in Alta Floresta - MT, and split into two pieces. The first verified that the petroleum hydrocarbons interfere with the population density of the bacterial communities of contaminated environments in seasonal periods of drought and flood, and the second examined the bacterial similarity between two contaminated monitoring wells. Ground water and local soil samples were collected using bailers contaminated and sterile plastic bottles, the samples were chilled packaged and transported according to standard techniques. In the first study evaluated the contaminated area in Alta Floresta, BTEX, environmental variables, and bacterial density of coliforms, Escherichia coli, total heterotrophic bacteria (THB) and degrading bacteria petroleum hydrocarbons. The survey to determine the contaminated areas was held at the SEMA-MT, and for BTEX was used gas chromatograph, mass detector and gun. The Multiparameter probe, in turn, was used to measure environmental variables, while the conventional microbiological techniques were used to determine the bacterial densities. In the second study analyzed environmental variables, BTEX, density and diversity of hydrocarbon degrading bacteria, having been used probe multiparameter to environmental variables, gas chromatograph, mass detector and gun for BTEX, in addition to conventional microbiological techniques for determine the bacterial density and molecular techniques (BOX-PCR and application Bionumerics 7.1) to determine the diversity. The research done in the first work confirmed that the city of Alta Floresta contained only two contaminated gas stations (data from the State Department of the Environment), and the analyzes performed in the study area found contamination by BTEX in the position where the study was conducted, and in some places the value was high as the PM2 had 597.05 μg/L. During the first collection, the highest results for the environmental variables were 6.87 for pH, 29.7°C, 6.96 mg/L of dissolved oxygen and 604 mS /m conductivity. The PM4 was the one with the highest density of coliform (5.95 Log MPN/100mL) during the second collection and absence of E. coli during both periods. To the ground, the point with greatest density was HBT S8 to 5.92 Log FUC/g and the water was PM4, during the first sample with Log 4.30 FUC/mL. The density of hydrocarbon degrading bacteria was higher in PM4 (3.68 Log FUC/mL) in the first collection. In the second working point the most contaminated was M1, and the t luene was und m e c mp und (267.08 μg/L), the highest density of petroleum degrading bacteria, in turn, was in PM2 to 4.05 Log FUC/mL. Diversity was higher in the PM1, with only 20% of the strains showed similarity of 100%. In general, the gas stations are areas susceptible to contamination, BTEX and environmental variables can alter the density and diversity of the bacterial communities of the contaminated site. With the results found in the study it was observed that the contamination at the site occurs diffusely and bioremediation hypothesis in the area can not be ruled out.
387

Análise de tendências hidrológicas na bacia do Rio das Mortes e suas relações com as mudanças na cobertura do solo

Rosin, Cássia 27 February 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-03-14T14:12:37Z No. of bitstreams: 1 DISS_2015_Cassia Rosin.pdf: 1981747 bytes, checksum: 255846d68f24309d20764dc0e60fdd9f (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-03-14T16:03:05Z (GMT) No. of bitstreams: 1 DISS_2015_Cassia Rosin.pdf: 1981747 bytes, checksum: 255846d68f24309d20764dc0e60fdd9f (MD5) / Made available in DSpace on 2017-03-14T16:03:05Z (GMT). No. of bitstreams: 1 DISS_2015_Cassia Rosin.pdf: 1981747 bytes, checksum: 255846d68f24309d20764dc0e60fdd9f (MD5) Previous issue date: 2015-02-27 / CAPES / O Cerrado mato-grossense sofreu intensivo processo de desmatamento a partir dos anos 60, por iniciativas do Governo Federal aliado a interesses internacionais que visavam o desenvolvimento da agricultura nessa região. Estimativas atuais indicam a existência de um remanescente de apenas 55% de Cerrado, porém, a fronteira agrícola continua em expansão, comprometendo estas áreas que ainda se encontram preservadas. Grande parte dos resultados encontrados na literatura sobre os efeitos da remoção da vegetação são referentes a florestas tropicais e ainda para bacias hidrográficas inferiores a 1 km². Para a Floresta Amazônica, foram realizados diversos estudos sobre o desmatamento. No entanto, há carência de estudos sobre os efeitos da transformação do Cerrado em paisagem agropastoril. Portanto, o presente trabalho visa correlacionar a mudança da cobertura do solo com a variação temporal da precipitação e vazão na bacia do Rio das Mortes. Para avaliar possíveis alterações hidrológicas, foram utilizadas series de precipitação e vazão de médias, máximas e mínimas diárias mensais e anuais dos períodos seco e chuvoso, para as quais realizou-se a análise de tendência de Mann-Kendall. De posse das series diárias mensais dos dados pluviométricos e fluviométricos, foram preparadas as médias decadais consecutivas, as quais foram apresentadas em gráficos bloxplot e as médias entre os três períodos (1975 a 1984; 1985 a 1994; e 1995 a 2004) foram comparadas pelo teste t-student. Para avaliação da cobertura do solo foram utilizadas imagens de 12 orbitas-pontos do satélite Landsat 5 sensor TM, com intervalo decadal, no período de 1984, 1994 e 2004. As imagens foram pré-processadas e classificadas pelo algoritmo vizinho mais próximo. As análises de tendências de Mann-Kendall para as séries temporais pluviométricas foram pouco expressivas resultando em apenas 11% das séries com tendências significativas, sugerindo que sistema climatológico local depende muito pouco da evaporação da superfície da área. As análises de tendências de Mann-Kendall para as séries temporais fluviométricas apresentaram tendências tanto negativas como positivas. A estação cujas análises apresentaram em todas as séries tendência negativa, demonstra forte conexão em relação ao tipo de uso e sobre-exploração dos recursos hídricos. Já nas estações que apresentaram tendência de aumento, podemos notar que o tipo de uso e as caraterísticas físicas do solo influenciam a dinâmica hídrica na bacia. Analisando as áreas de vegetação nativa da Bacia do Rio das Mortes, verifica-se que houve uma redução das mesmas nos anos de 1984, 1994 e 2004, as quais correspondem, respectivamente, a 79%, 71% e 57% da área. Enquanto as classes que expressam uso antrópico em 1984 ocupavam 21% da bacia e em 2004 passaram a ocupar 43% da área da bacia do Rio das Mortes. A redução da vegetação nativa e aumento das classes de uso antrópico se deu de forma mais intensa na região do Alto Rio das Mortes, resultando em alteração da vazão que apresentou redução de fluxo em função da sobre-exploração. Porem a analise das estações pluviométricas evidencia grande variabilidade na precipitação, o que sugere que o sistema climatológico local possa ter maior dependência dos padrões de circulação atmosféricos que da evaporação da superfície da área. / The Mato Grosso Cerrado suffered intensive deforestation process from the 60s, by Federal Government initiatives combined with international interests aimed at the development of agriculture in this region. Current estimates indicate that there is a remnant of only 55% of Cerrado, however, the agricultural frontier continues to expand, committing these areas that are still preserved. Much of the results found in the literature on the effects of vegetation removal are for tropical forests and watersheds yet for less than 1 km². To the Amazon rainforest, were conducted several studies on deforestation. However, there are few studies on the effects of the transformation of the Cerrado in agropastoral landscape. Therefore, this study intends to correlate the change of land cover with the temporal variation of precipitation and flow in the Rio das Mortes. To evaluate possible hydrological changes were used series of precipitation and flow averages, monthly and annual daily maximum and minimum of dry and wet periods, for which there was the Mann-Kendall trend analysis. Having the monthly series of daily rainfall and runoff data were prepared averages consecutive decadal, which were presented in bloxplot graphics and the average of the three periods (1975-1984, 1985-1994, and 1995-2004) were compared by Student's t-test. For assessment of land cover were used images of 12-point orbits of Landsat 5 TM sensor, with decadal interval, from 1984, 1994 and 2004. The images were pre-processed and classified by the nearest neighbor algorithm. Analysis Mann-Kendall trends for rainfall was insignificant time series resulting in only 11% of the series with significant trends suggesting that the local climatological system depends very little evaporation of surface area. Analyses of Mann-Kendall trend for fluviometric time series presented both negative and positive trends. The station whose analyzes presented in all negative trend series shows strong connection with the type of use and over-exploitation of water resources. Already in the stations showed an increasing trend, we note that the type of use and the physical characteristics of the soil influence the water dynamics in the basin. Analyzing the areas of native vegetation of the Rio das Mortes Basin, it appears that there was a reduction of the same in 1984, 1994 and 2004, which correspond, respectively, to 79%, 71% and 57% of the area. While the classes expressing anthropic use in 1984 occupied 21% of the basin and in 2004 came to occupy 43% of the basin area of Rio das Mortes. The reduction of native vegetation and increased anthropogenic use classes occurred more intensely in the Upper Rio das Mortes region, resulting in change of flow that decreased flow due to the over-exploitation. However, analysis of rainfall stations shows great variability in the precipitation, which suggests that local climatological system can be increased reliance on air flow patterns that the evaporation surface area.
388

Densidade e caracterização genotípica das linhagens de ferrobactérias isoladas de água de poços rasos em Cuiabá - Mato Grosso

Ramos, Pâmila Nayana Ferreira 02 February 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-03-18T12:36:02Z No. of bitstreams: 1 DISS_2015_Pâmila Nayana Ferreira Ramos.pdf: 1319570 bytes, checksum: e4382482fe0507e46d18d8e8662bc3c2 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-03-18T15:10:36Z (GMT) No. of bitstreams: 1 DISS_2015_Pâmila Nayana Ferreira Ramos.pdf: 1319570 bytes, checksum: e4382482fe0507e46d18d8e8662bc3c2 (MD5) / Made available in DSpace on 2017-03-18T15:10:36Z (GMT). No. of bitstreams: 1 DISS_2015_Pâmila Nayana Ferreira Ramos.pdf: 1319570 bytes, checksum: e4382482fe0507e46d18d8e8662bc3c2 (MD5) Previous issue date: 2015-02-02 / A utilização de poços rasos como fonte de abastecimento de água é uma prática comum em todo o mundo devido à qualidade dos aquíferos serem adequadas para diversos usos, principalmente ao consumo humano. Todavia, a poluição desse recurso pode ocorrer por diversas formas, como a contaminação bacteriológica, mais especificamente por Ferrobactérias. Assim sendo, este estudo tem como objetivo analisar o perfil genotípico de Ferrobactérias isoladas da água de poços rasos no Bairro Pedra Noventa, Cuiabá-MT. As coletas de água nos pontos amostrais foram realizadas em novembro de 2013 (início do período chuvoso) e janeiro de 2014 (chuvas regulares), no Bairro Pedra Noventa, em Cuiabá, utilizando como amostrador o manual tipo bailer. Após a quantificação das Ferrobactérias, via meio seletivo, foram isoladas para extração de DNA e caracterização genotípica utilizando o iniciador BOX-PCR. A partir do produto da eletroforese do BOXPCR, foram gerados dezesseis géis que contabilizam dezessete pontos para cada período amostral. A similaridade das amostras foi determinada por matrizes binárias de presença e ausência para cada um dos pontos de análise, em função da posição que as bandas ocupavam no gel. A partir da matriz de dissimilaridade foram agrupados em dendrogramas UPGMA e análise de similaridade de Jaccard (2%) para o percentual de similaridade entre os isolados de cada ponto. Para análises do metal ferro foram realizadas duas coletas em dois períodos distintos os pontos P2, P7, P10 e P16, apresentaram concentrações acima aos Valores Máximos Permissíveis para consumo humano. Para análises microbiológicas todas as amostras analisadas apresentaram contaminação por Ferrobactérias. Através dos dendrogramas de dissimilaridade, notou-se que 10,9% dos isolados obtiveram uma similaridade acima de 70%, o que leva a inferir que 89,1% dos isolados apresentaram diversidade gênica. / The use of shallow wells as water source is a common practice worldwide for the quality of aquifers are suitable for various uses, mainly for human consumption. However, pollution of this resource can occur in various forms, such as bacterial contamination, specifically by Iron Bacteria. Therefore, this study aims to analyze the genotypic profile of Iron Bacteria isolated from water from shallow wells in the neighborhood Stone Ninety, Cuiaba-MT. The water sampling in the sampling points were held in November 2013 (the beginning of the rainy season) and January 2014 (regular rainfall), in the neighborhood Stone Ninety in Cuiaba, as sampler using the manual type bailer. After quantification of Iron Bacteria, via selective medium, were isolated for DNA extraction and genotypic characterization using BOX-PCR primer. From the product of BOX-PCR electrophoresis, gels were generated which account sixteen seventeen points for each sampling period. The similarity of the samples was determined by binary matrices presence and absence for each of the analysis points, depending on the position occupied bands in the gel. From the dissimilarity matrix were grouped into UPGMA dendrograms and Jaccard similarity analysis (2%) to the percentage of similarity among isolates of each point. To iron metal analyzes were performed two collections into two distinct periods points P2, P7, P10 and P16 showed concentrations above the Maximum Allowable Values for human consumption. For microbiological analyzes all samples were contaminated by Iron Bacteria. Through dendrograms dissimilarity, it was noticed that 10.9% of the isolates obtained a similarity greater than 70%, which leads to the inference that 89.1% of the isolates showed genetic diversity.
389

Estudo da qualidade física e química das águas subterrâneas da área urbana de Sinop/MT

Knechtel, Régis 28 February 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-03-18T13:08:07Z No. of bitstreams: 1 DISS_2015_Régis Knechtel.pdf: 3190530 bytes, checksum: 1a53fffb95e0f9867a330ff74d0ee9b8 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-03-18T15:11:40Z (GMT) No. of bitstreams: 1 DISS_2015_Régis Knechtel.pdf: 3190530 bytes, checksum: 1a53fffb95e0f9867a330ff74d0ee9b8 (MD5) / Made available in DSpace on 2017-03-18T15:11:40Z (GMT). No. of bitstreams: 1 DISS_2015_Régis Knechtel.pdf: 3190530 bytes, checksum: 1a53fffb95e0f9867a330ff74d0ee9b8 (MD5) Previous issue date: 2015-02-28 / As águas subterrâneas têm se tornado um recurso cada vez mais explorado no mundo todo e Sinop-MT não é exceção. Com abastecimento público e privado exclusivamente subterrâneo, a cidade pode ser considerada um local de alta vulnerabilidade à contaminação, devido à sua localização sobre os aquíferos do Grupo Parecis, que possuem alta condutividade hidráulica e nível freático muito próximo à superfície. Nesse contexto, o presente estudo tem por objetivo principal estudar a qualidade das águas subterrâneas da área urbana de Sinop-MT através da determinação dos seus parâmetros físicos e químicos, de forma a subsidiar a conservação desse recurso, bem como possibilitar a validação de mapas de vulnerabilidade em estudos futuros. Devido à composição essencialmente quartzo-feldspática do Grupo Parecis, as águas da região apresentam baixa concentração de todos os íons analisados, pouca salinidade, pH com tendência ácida e alcalinidade e dureza baixas. Também foi detectada uma possível contaminação em um dos poços da cidade, podendo ser causada por problemas construtivos. Apesar disso, as águas apresentaram boa qualidade física e química e, com a adequação dos despejos de efluentes domésticos e industriais da cidade e maior controle no uso de defensivos agrícolas, é possível garantir a conservação do Sistema Aquífero Parecis. / Groundwater has become an increasingly exploited resource worldwide, and Sinop-MT is no exception. With public and private supply exclusively underground, the city can be considered as a high vulnerability site to contamination due to its location on the Parecis Group aquifers, which has a high hydraulic conductivity and water table very close to the surface. In this context, the main objective of this work is to study the groundwater quality of Sinop-MT urban area by determining their physical and chemical parameters, in order to support the conservation of this resource and to enable the validation of vulnerability maps in forthcoming studies. Due to its essentially quartz-feldspar composition, the Parecis Group groundwaters have low concentration of all the analyzed ions, low salinity, pH trending to acidic and low alkalinity. A possible contamination was also detected in one of the city wells, which may be caused by constructive problems. Nevertheless, the waters have good physical and chemical quality and, with the adequacy of domestic and industrial waste dumps of the city and greater control over the use of pesticides, it is possible to ensure the conservation of the Parecis Aquifer System.
390

Caracterização da qualidade da água pluvial retida em módulos experimentais de telhados verdes e o seu estudo como alternativa tecnológica para redução do volume da água pluvial escoada

Vacari, Thaisa Camila 11 December 2015 (has links)
Submitted by Jordan (jordanbiblio@gmail.com) on 2017-03-18T14:30:48Z No. of bitstreams: 1 DISS_2015_Thaisa Camila Vacari.pdf: 1558380 bytes, checksum: dcb4da4099b9976d50084ce1abf2a5e3 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-03-18T15:15:38Z (GMT) No. of bitstreams: 1 DISS_2015_Thaisa Camila Vacari.pdf: 1558380 bytes, checksum: dcb4da4099b9976d50084ce1abf2a5e3 (MD5) / Made available in DSpace on 2017-03-18T15:15:39Z (GMT). No. of bitstreams: 1 DISS_2015_Thaisa Camila Vacari.pdf: 1558380 bytes, checksum: dcb4da4099b9976d50084ce1abf2a5e3 (MD5) Previous issue date: 2015-12-11 / CAPES / FAPEMAT / A alternativa tecnológica de telhados verdes tem sido usada há muitos anos por países europeus e norte-americanos, porém somente na última década tem ganhado mercado no Brasil. Entre seus benefícios estão a redução de ilhas de calor, a diminuição das variações de temperatura, a minimização de ruídos e poluição do ar. Também podem aumentar a biodiversidade urbana e tornar o ambiente esteticamente mais agradável. Ainda podem melhorar a gestão de águas pluviais e a sua qualidade desta água. Por isso este estudo teve como objetivo caracterizar qualitativamente as águas pluviais captadas de módulos experimentais de telhados verdes, com três tipos diferentes de vegetações localizados no município de Cuiabá, MT. E também, avaliar a porcentagem de retenção das águas pluviais captadas pelos mesmos módulos experimentais de telhados verdes e analisar se a intensidade da chuva influencia o volume de água pluvial retido. Para isso foram construídos três módulos de telhados verdes testando três vegetações diferentes que foram comparados a um telhado convencional. Na água captada dos telhados foram analisadas quinze variáveis de qualidade da água. Assim com relação à qualidade da água captada pelos módulos experimentais de telhados verdes foi possível observar que aumentaram as características da cor e turbidez e atuaram como concentradores de todos os nutrientes analisados. As concentrações de DBO, bactérias heterotróficas e fungos cultiváveis não apresentaram diferenças entre telhado convencional e telhados verdes. Em relação aos coliformes totais nos telhados verdes os resultados apresentaram valores de concentrações superiores ao telhado convencional, porém, o contrário ocorreu em relação à Escherichia coli. Também se notou que não há vegetação mais adequada para melhorar a qualidade da água, pois diversos são fatores que a influenciam e que cada vegetação atua de forma diferente. Os telhados verdes podem ser usados como minimizadores de problemas relacionados à drenagem urbana, já que os resultados demostraram que os telhados verdes podem reter de 46 a 61% da água. Ainda se observou que o tipo de vegetação do telhado verde tem efeito sobre as quantidades de retenção de escoamento e que os telhados verdes de herbácea e gramínea foram os que apresentaram maior porcentagem de retenção da água pluvial drenada por eles. Também se observou que existe uma relação inversa entre a intensidade da precipitação e a porcentagem de águas pluviais que é retida pelos telhados verdes, pois quanto menor a intensidade da chuva maior é o volume retido de água pluvial. / The alternative technology of green roofs has been used for many years by European and North American countries, but only in the last decade has gained market in Brazil. Among its benefits are the reduction of heat islands, the decrease of temperature variations, minimizing noise and air pollution. They can also increase urban biodiversity and make more aesthetically pleasing environment. Still can improve stormwater management and the quality of this water. Therefore, this study aimed to qualitatively characterize the rainwater captured experimental modules of green roofs, with three different types of vegetation located in the city of Cuiabá, MT. Also, evaluate the percentage of retention of rainwater captured by the same experimental modules of green roofs and analyze the intensity of rain influences the volume of retained rainwater. For that it was built three modules of green roofs testing three different vegetations were compared to a conventional roof. The water collected from the roofs were analyzed fifteen variables of water quality. So with regard to the quality of water abstracted by the experimental modules of green roofs has been observed that increased color characteristics and turbidity and acted as hubs of all analyzed nutrients. The concentrations of BOD, heterotrophic bacteria and fungi cultivated no differences between conventional roof and green roofs. In relation to total coliforms in green roofs results showed values of concentrations exceeding the conventional roof, however, the opposite occurred with respect to Escherichia coli. It was also noted that there is no longer adequate vegetation to improve the quality of the water, as are many factors that influence and that each vegetation operates differently. Green roofs can be used as minimizing problems related to urban drainage, since the results showed that green roofs can retain 46-61% water. Yet it was observed that the type of green roof vegetation has an effect on the flow retention amounts and green roofs of herbaceous and grassy showed the highest percentage of retention of rainwater drained by them. It was also observed that there is an inverse relationship between the intensity of precipitation and the percentage of rainwater is retained by green roofs, because the lower the intensity of the rain is higher retained volume of rainwater.

Page generated in 0.1106 seconds