• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 238
  • 1
  • 1
  • Tagged with
  • 243
  • 70
  • 67
  • 67
  • 62
  • 62
  • 49
  • 43
  • 30
  • 30
  • 28
  • 27
  • 25
  • 23
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Caracterização térmica, grau de conversão, resistência à flexão e dureza de compósitos comerciais tratados termicamente / Thermal characterization, degree of conversion, flexural strength and Knoop hardness of heat treated commercial composites

Miyazaki, Caroline Lumi 03 August 2010 (has links)
Visando otimizar as propriedades químicas e mecânicas de compósitos de uso direto aplicados na forma indireta, associados a tratamentos térmicos experimentais (TT), torna-se necessária uma caracterização térmica que permita a determinação de uma temperatura de TT segura (abaixo da temperatura de início de perda de massa). Assim, a primeira etapa deste estudo consistiu em caracterizar termicamente dez compósitos comerciais (Z100, Filtek Z250, Z350 e Supreme XT- 3M ESPE, Esthet-X e TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV e Point 4 - Kerr), fotoativados pelo método contínuo (C) e pulse-delay (PD) (20 J.cm-2), por termogravimetria (TG) (n=1) e calorimetria exploratória diferencial (DSC) (n=3). Foram escolhidas duas temperaturas de TT: 100 e 170°C, aplicadas por 10 min, 24h após a fotoativação. A partir disto, avaliaram-se: 1) o grau de conversão (GC), por espectroscopia FT-Raman (n=3); 2) a resistência à flexão em três pontos (RF) (n=10); e 3) a dureza Knoop (KHN) para as faces topo e base (n=3) de quatro destes compósitos (Filtek Z250 e Supreme XT, Esthet-X e Point 4), após diferentes condições: imediatamente, 1h, 6h e 24h após a fotoativação e 24h após fotoativação seguida de TT a 100 ou 170°C. Os dados obtidos foram submetidos à análise de variância e ao teste de Tukey (nível de significância de 5%). Quanto ao GC (%), houve significância estatística para o fator material (p=0,000): Point 4 (68,42) > Z250 (63,05) = Esthet-X (61,69) > Supreme (54,27); condição (p=0,000): TT170 (73,20) = TT100 (73,58) > 24h (62,60) = 6h (60,18) > 1h (55,10) = imediato (53,66); e ativação (p=0,006): C (62,97) > PD (60,75). Também foram significantes as interações material × condição (p=0,007) e material × condição × ativação (p=0,013). Para a RF (MPa), foram encontradas significâncias estatísticas para os fatores material (p=0,000): Z250 (165,48) > Supreme (153,96) > Point 4 (131,30) = Esthet-X (128,06); e condição (p=0,000): TT170 (194,56) > TT100 (182,91) > 24h (150,88) > 6h (131,79) > 1h (111,77) > imediato (96,30); assim como para as interações: ativação × condição (p=0,000), material × condição (p=0,000) e material × ativação × condição (p=0,000). Para a dureza, foram encontradas significâncias estatísticas para os fatores: materialativação (p=0,000): Supreme C (82,46) > Supreme PD (80,29) = Z250 C (77,46) > Z250 PD (74,30) > Esthet-X C (69,17) > Esthet-X PD (65,67) > Point 4 C (57,21) = Point 4 PD (56,71); condição (p=0,000): TT170 (81,35) > TT100 (73,72) > 24h (70,36) > 6h (67,92) > 1h (64,99) > imediato (64,12) e face (p=0,000): topo (71,40) > base (69,40); assim como para as interações: material-ativação × face (p=0,011), material-ativação × condição (p=0,000) e face × condição (p=0,000). A partir dos resultados obtidos, pôde-se concluir que os TTs experimentais propostos foram capazes de aumentar as propriedades estudadas, sendo, de maneira geral, os resultados obtidos com 170°C melhores do que os com 100°C, e ambos melhores do que as demais condições. / Aiming to optimize chemical and mechanical properties of direct composites applied in an indirect way, with an association to experimental heat treatments (TT), it is necessary a thermal characterization, in a way to determine a safe temperature for the TT (below the significant mass loss temperature). Thus, the first step of this study was to perform the thermal characterization of ten commercial composites (Z100, Filtek Z250, Z350 and Supreme XT 3M-ESPE, Esthet-X and TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV and Point 4 - Kerr) photoactivated by continuous (C) and pulse-delay (PD) methods (20 J.cm-2), by thermogravimetry (TG) (n=1) and differential scanning calorimetry (DSC) (n=3). After that, two temperatures were chosen for the TT: 100 and 170°C, which were applied for 10 min, 24h after photoactivation. Thus, some properties were evaluated for four composites (Filtek Z250 and Supreme XT, Esthet- X and Point 4): 1) degree of conversion (GC) by FT-Raman spectroscopy (n=3); 2) three-point bending test (RF) (n=10); and 3) Knoop hardness (KHN) for top and bottom surfaces (n=3). The conditions were: immediately, 1h, 6h and 24h after photoactivation and 24h after photoactivation followed by TT at 100 or 170°C. Data were analyzed by ANOVA and Tukeys test (level of significance of 5%). In relation to GC (%), there were statistical significance for the factors material (p=0.000): Point 4 (68.42) > Z250 (63.05) = Esthet-X (61.69) > Supreme (54.27); condition (p=0.000): TT170 (73.20) = TT100 (73.58) > 24h (62.60) = 6h (60.18) > 1h (55.10) = immediately (53.66); and activation (p=0.006): C (62.97) > PD (60.75); and for the interactions: material × condition (p=0.007) and material × condition × activation (p=0.013). For RF (MPa), statistical significance were found for the factors material (p=0.000): Z250 (165.48) > Supreme (153.96) > Point 4 (131.30) = Esthet-X (128.06); and condition (p=0.000): TT170 (194.56) > TT100 (182.91) > 24h (150.88) > 6h (131.79) > 1h (111.77) > immediately (96.30); and also for the interactions: activation × condition (p=0.000), material × condition (p=0.000) and material × activation × condition (p=0.000). For KHN, statistical significance were found for the factors material-activation (p=0.000): Supreme C (82.46) > Supreme PD (80.29) = Z250 C (77.46) > Z250 PD (74.30) > Esthet-X C (69.17) > Esthet-X PD (65.67) > Point 4 C (57.21) = Point 4 PD (56.71); condition (p=0.000): TT170 (81.35) > TT100 (73.72) > 24h (70.36) > 6h (67.92) > 1h (64.99) > immediately (64.12), and face (p=0.000): top (71.40) > bottom (69.40); as for the interactions: material-activation × face (p=0.011), material-activation × condition (p=0.000) and face × condition (p=0.000). By the results, it could be concluded that both proposed experimental TTs were capable of increasing the studied properties, with, in a general way, 170°C generating better mechanical properties than 100°C, and both better than the other conditions.
112

Contribuições teórico-experimentais para a definição das propriedades mecânicas do concreto com fibras aplicadas em simulações numéricas com foco na interação flexão-cisalhamento em vigas de concreto armado / Theoretical-experimental contributions for the definition of the mechanical properties of steel fiber reinforced concrete applied in numerical simulations focusing on the flexion-shear interaction in reinforced concrete beams

Silva, Matheus Fernandes de Araújo 28 January 2019 (has links)
A verificação ao cisalhamento de vigas de concreto armado é realizada, geralmente, assumindo sua independência do comportamento à flexão. Dentre os mecanismos que influenciam na resistência à força cortante, a força cortante transmitida pelo banzo comprimido da viga e o engrenamento de agregados são os mais abordados em pesquisas nos ultimos anos. Ambos dependem do nível de tensões normais atuante na seção do elemento. Sendo assim, o comportamento ao cisalhamento fica evidentemente dependente do comportamento à flexão e de como o concreto se comporta à tração e à compressão. Para melhor entender este comportamento, este trabalho compreendeu duas frentes de análise: experimental e numérica. Ensaios de tirantes foram realizados no intuito de avaliar o enrijecimento à tração do concreto com fibras. Além disso, ensaios de flexão em três pontos em prismas de 15cm x 15cm x 50 cm foram feitos para avaliar o comportamento pós-pico à tração do concreto. Ensaios de compressão em cilindros de concreto 10×20cm foram realizados de maneira a apontar estimativas para a energia de fratura à compressão e o comportamento pós-pico do concreto com diferentes taxas volumétricas de fibras. Seguindo os resultados experimentais, simulações numéricas dos ensaios de flexão em três pontos e dos ensaios de compressão foram desenvolvidas com o intuito de melhorar o entendimento dos ensaios realizados. Estes estudos aperfeiçoaram primordialmente os conhecimentos do comportamento do concreto à tração e compressão pós-fissuração. Foram ensaiadas nove vigas de concreto armado variando volume de fibras e a relação entre a distância da carga até o apoio mais próximo e a altura útil da viga ( a / d). Os resultados destes ensaios mostram que a resistência à força cortante aumenta com a taxa volumétrica de fibras e que o esquema estático adotado interfere pouco na resistência. Além disso, os resultados do estudo de caracterização do comportamento pós-pico do concreto foi aplicado na simulação numérica da viga. Os resultados numéricos apontam diferenças na rigidez global quando comparados com os resultados experimentais. / The shear strength verification of reinforced concrete beams is generally performed assuming their independence from the flexural behavior. Among the mechanisms that influence the shear strength, the shear force transmitted by the concrete compressed zone of the beam and the aggregate interlock are the most studied in the last years. Both depend on the level of normal stresses acting on the element section. Therefore, the shear behavior is obviously dependent on the flexural behavior and how the concrete behaves in tension and compression. For a better understanding, this work comprised two fronts of analysis: experimental and numerical. Tension ties tests were performed in order to evaluate the tension stiffening of concrete with fibers. In addition, three-point bending tests on 15cm x 15cm x 50cm prisms were made to evaluate the post-peak tension behavior of the concrete, or tension softening. Compression tests on 10 × 20cm concrete cylinders were carried out in order to estimate the compression fracture energy and the post-peak behavior of concrete with different volumetric fiber rates. Following the experimental results, numerical simulations of the three-point bending tests and the compression tests were developed with the aim of improving the understanding of the tests performed. These studies have the aim of improving the understanding of the three-point bending and compression tests performed. Nine reinforced concrete beams were tested, varying the volume of fibers and the relation between the distance of the load to the closest support and the useful height of the beam (a/d). The results of these tests show that shear strength increases with the volumetric rate of fibers and that the static scheme adopted does not interfere in resistance. In addition, the results of the post-peak concrete characterization study of the concrete were applied in the numerical simulation of the beam. Numerical results show differences in overall stiffness when compared with experimental results.
113

Cervical muscle strength and motor control assessment using dynamometry and surface electromyography in women with migraine and chronic migraine: a controlled study / Avaliação da força máxima e do controle motor da coluna cervical pela dinamometria e pela eletromiografia de superfície em mulheres com migrânea e migrânea crônica: estudo controlado

Florencio, Lidiane Lima 08 February 2017 (has links)
Objectives: to verify if women with migraine present altered neck muscles function and altered muscle activity in comparison to non-headache subjects. Moreover, we aimed to identify if there is any relationship between neck muscles dysfunction and the chronicity of migraine attacks. Methods: women with migraine, stratified by episodic and chronic, and age-matched non headache women were the subject of the current thesis. Neck pain relateddisability was assessed by the Neck Disability Index. Neck muscles strength was assessed by a customized hand-held dynamometer. Myoelectrical signals of the sternocleidomastoid, anterior scalene, splenius capitis and upper trapezius were assessed using surface electromyography. Experimental conditions involved maximal isometric voluntary contractions in flexion, extension and lateral bending directions and; craniocervical flexion test, a low load test applied to verify deep cervical flexors ability to supply adequate cervical spine stability. Finally, identification of myofascial trigger points and head and cervical posture photogrammetric evaluation were made in order to be correlated to the muscles electrical activity in the craniocervical flexion test. Results: Although both groups presents high prevalence of neck related disability, subjects with chronic migraine are more likely to report neck related disability, especially the most disabling forms, than episodic migraine. Episodic migraine demonstrated to different neck muscle control only under maximal voluntary tasks. Chronic migraine presented alterations in comparison with controls at maximal conditions, i.e., lower extension force; more time to produce maximal force; greater antagonist coactivation and greater fatigability. During craniocervical flexion test, chronic migraine also differs from control group presenting greater activity of neck extensors. Presence of active trigger points in neck muscles and extended head posture can influence the neck muscles activity during the craniocervical flexion test. Conclusions: migraine is associated to a deterioration of neck muscles functions and to an altered motor control. We can assume an interaction between chronicity of migraine frequency and cervical dysfunction, specially related to neck extensors. More severe disabilities and the majority of the altered function or motor control could only be evidenced in the chronic form / Objetivos: verificar se mulheres com migrânea apresenta alteração na função e atividade dos músculos do pescoço quando comparados a mulheres sem cefaleia. Ainda, objetivamos identificar se há relação entre disfunção cervical muscular e a cronicidade da frequência de crises migranosas. Materiais e métodos: mulheres com migrânea, estratificada entre episódica e crônica, e mulheres sem cefaleia com idade semelhante foi o objeto de estudo dessa tese. Foi investigada a incapacidade relacionada à dor cervical pelo questionário Neck Disability Index e a força muscular cervical utilizando um dinamômetro manual customizado. Ainda, a atividade elétrica dos músculos esternocleidomastoideo, escaleno anterior, esplênio da cabeça e trapézio superior foi verificada pela eletromiografia de superfície. Os procedimentos experimentais foram contração isométrica voluntária máxima em flexão, extensão e inclinação lateral; e o teste de flexão craniocervical, que avalia a habilidade dos músculos flexores cervicais profundos em prover adequada estabilidade para esse segmento. Por fim, a identificação de pontos gatilhos nos músculos cervicais e a avaliação da postura da cabeça e do pescoço por foto foram realizadas a fim de correlacionar os achados com a atividade eletromiográfica. Resultados: embora ambos os grupos de migrânea tenham apresentado alta prevalência de incapacidade relacionada à dor cervical, a migrânea crônica apresenta maior risco de relatar incapacidades mais severas em relação a migrânea episódica. O grupo de migrânea episódica apresentou controle muscular cervical alterado em condição de contração voluntária máxima. Já o grupo migrânea crônica apresentou alterações sob condições máximas, como por exemplo, redução da força dos extensores, mais tempo para gerar pico de força em flexão e inclinação lateral, maior coativação do antagonista e maior susceptibilidade à fadiga. Ainda, durante o teste de flexão craniocervical, o grupo migrânea crônica apresentou maior atividade dos extensores indicando alteração no controle motor. A presença de pontos gatilhos nos músculos do pescoço e a postura em extensão de cabeça pode influenciar a atividade elétrica dos músculos cervicais durante a execução do teste de flexão craniocervical. Conclusões: a migrânea está associada a uma deteriorização da função e do controle motor cervical. Podemos assumir ainda que há uma interação entre a cronicidade da frequência das crises migranosas e a disfunção muscular cervical, especialmente relacionada aos extensores. Incapacidades mais severas e a maioria das disfunções musculares e alteração no controle motor só puderam ser evidenciadas para o grupo com migrânea crônica
114

Estudo biomecânico comparativo da resistência de segmentos ósseos de rádios de cães autoclavados ou desvitalizados em nitrogênio líquido / Biomechanical comparative study of the strength of autoclaved and devitalized in liquid nitrogen bone segments from the radius of dogs

Bó, Ísis dos Santos Dal 27 February 2015 (has links)
O presente estudo visa comparar biomecanicamente, por meio do ensaio de flexão em quatro pontos, a resistência de segmentos de rádios de cães autoclavados e desvitalizados em nitrogênio líquido. Foram utilizados 20 cadáveres de cães de mais de dois anos de idade e massa corporal superior a 20 kg, portanto 40 rádios, que foram divididos em quatro grupos: grupo autoclave (GA), grupo controle autoclave (GCA), grupo nitrogênio (GN) e grupo controle nitrogênio (GCN). Os corpos de prova dos grupos GCA e GCN pertenciam ao lado contralateral dos grupos GA e GN, respectivamente. Os ossos foram autoclavados a 121ºC, por 20 min a 2 atm. A desvitalização em nitrogênio foi realizada por meio da imersão em nitrogênio líquido, por 20 min, seguida de descongelamento à temperatura ambiente, sendo finalizada por imersão em solução de NaCL a 0,9%, por mais 15 min. A avaliação da resistência biomecânica foi realizada pelo ensaio de flexão em quatro pontos. Foi utilizado o programa de computador PMI para calcular o momento de inércia após o ensaio biomecânico destrutivo. Foram comparadas as variáveis força máxima, rigidez, altura máxima à secção transversa do corpo de prova, deslocamento do baricentro em relação ao eixo x, flecha, tensão-tração, tensão compressão e tensão máxima. Não foram encontradas diferenças estatisticamente significantes entre os grupos GN e GCN. Foram encontradas diferenças estatisticamente significantes entre os grupos GA e GCA somente na comparação da variável força máxima. A análise das variáveis tensão-tração, tensão-compressão e tensão máxima evidenciou diferenças estatisticamente significantes entre os grupos GA e GN, sendo os valores maiores para o grupo GA. Também foi realizada comparação entre os deltas (GN menos GCN e GA menos GCA) em que não foram observadas diferenças estatísticas. / The present study aim to, biomechanically compare through the four points bending test, the strenght of autoclaved and devitalized in liquid nitrogen radius segments. 20 corpses of dogs (>2 years of age and >20 kg of weight) were used. 40 radius were collected and divided into 4 groups, Autoclave Group (GA), Control Autoclave Group (GCA), Nitrogen Group (NG) and Control Nitrogen Group (GCN). Bone segments from groups GCA and GCN were contralateral to GA and NG. The segments were autoclaved at 121ºC and 2 atm for 20 minutes. Nitrogen devitalization of the bone segments was obtained by 20 minutes immersion, followed by thawing at room temperature and 15 minutes immersion in 0,9% NaCL solution. The biomechanical strenght evaluation was performed in the four points bending test; afterwards, PMI computer program calculated the moment of inertia after the destructive biomechanical assay. Variables compared were maximum strength, stiffness, maximum high trough the transverse section of the bone segment, centers of mass dislocation in relation to x axe, arrow, stress-tension, stress-compression and maximum stress. No statistically significant differences between the GN and GCN groups were found. Statistically significant differences were found between groups GA and GCA only in the comparison of the maximum force variable. The analysis of variable stress-tension, stress-compression and maximum stress showed statistically significant differences between the GA and GN groups, with higher values for the GA group. Comparison of the deltas (GN least GCN and GA least GCA) that no statistical differences were observed was also performed.
115

Avaliação de critérios de falhas de compósitos poliméricos reforçados aplicados a vigas sob carregamento de flexão / Evaluation of failure criteria for reinforced composite materials applied on beams submited to flexural loads

Souza, Gilberto Pereira de 15 September 2003 (has links)
Este trabalho apresenta um estudo de aplicabilidade de diferentes critérios de falhas para materiais compósitos poliméricos reforçados, especificamente laminados compostos de fibras unidirecionais, submetidos a carregamento de flexão. Consiste inicialmente de um levantamento bibliográfico para descrever os principais mecanismos de falhas e como estes podem ser analisados. É realizada uma avaliação dos principais critérios de falhas existentes, em estudos de casos de vigas do material submetidas a esforços de flexão três pontos. Para tal avaliação utilizou-se o método dos elementos finitos, devido à complexidade da análise de tensões em compósitos poliméricos reforçados. Posteriormente foram implementadas rotinas computacionais para o cálculo de alguns dos critérios de falhas encontrados na literatura. Assim, analisou-se as potencialidades e limitações desses critérios nos estudos de caso abordados. / This work presents a study about the applicability of different failure criteria for laminated reinforced composite materials made of unidirectional fibers, under flexural loads. First, it is described the failure mechanisms of this material, and how this can be evaluated. Some of the most important failure criteria are tested for beams under flexural loads. Because of the complexity of composite stress analysis, it was used the Finite Element Method. After that, some computational routines were implemented to calculate the failure criteria. The advantages and limitations of these theories could be verified for the flexural case studies.
116

A influência da não-linearidade física do concreto armado na rigidez à flexão e na capacidade de rotação plástica. / The influence of physical non-linearity of the reinforced concrete on flexural rigidity and on plastic rotation capacity.

Buchaim, Roberto 18 July 2001 (has links)
O presente trabalho é uma contribuição para o esclarecimento e a quantificação das influências na deformabilidade e na capacidade portante de elementos unidimensionais de concreto armado em solicitação plana, decorrentes da não-linearidade física dos materiais concreto e aço, bem como da fissuração e do enrijecimento da armadura tracionada, também na sua fase plástica. Para aplicações práticas determinam-se a rigidez à flexão e a capacidade de rotação plástica dos elementos estruturais, o que permite limitar com mais precisão e coerência a demanda de rotação plástica obtida na análise. De início, descrevem-se os comportamentos não-lineares do concreto e do aço, aplicando-se conceitos da Mecânica da Fratura, bem como a atuação conjunta destes materiais, sob os aspectos de aderência e de fissuração. O núcleo deste trabalho concentra-se na obtenção do diagrama momento-curvatura e dos seus pontos principais, e na subseqüente determinação da capacidade de rotação plástica dos mencionados elementos. Consideram-se as seções geradas a partir da seção duplo T assimétrico, com várias camadas de armadura, sujeitas à flexão composta normal. Com dados deste diagrama e através do modelo da viga equivalente simétrica, posteriormente estendido à viga equivalente assimétrica e às vigas contínuas de pórticos planos, determina-se a capacidade de rotação plástica, considerando-se nesta suas múltiplas influências. Por fim, comparam-se os resultados teóricos e experimentais da capacidade de rotação plástica, e resumem-se as principais conclusões encontradas e os pontos que exigem subseqüente desenvolvimento. / The present study is a contribution to the enlightenment and evaluation of the influences on deformability and load carrying capacity of one-dimensional elements of reinforced concrete subject to in-plane loading, arisen from the constitutive non-linearity of concrete and steel, as well as from the concrete cracking and the tension stiffening of the reinforcement, prior and after yielding. For practical applications, the flexural rigidity and the plastic rotation capacity of structural elements are determined, which makes it possible to limit, more precisely and coherently, the plastic rotation demand coming from the analysis. Firstly, the non-linear behaviors of concrete and steel are described, applying concepts of Fracture Mechanics, and then the joint action of both materials concerning bond and cracking is studied. The core of this study lies on obtaining the bending moment-curvature diagram, specially its main points, and on the subsequent determination of the plastic rotation capacity of the aforementioned elements. The cross-sections generated from an asymmetric double T cross-section are considered, with several layers of reinforcement, acted upon simple or combined bending about one principal axis. With data based on this diagram and through the model of equivalent symmetric beam, later extended to equivalent asymmetric beam and to continuous beams of plane frames, the plastic rotation capacity is determined, considering its multiple influences. Finally, theoretical and experimental results of plastic rotation capacity are compared, and the main conclusions and points in need of subsequent development are summarized.
117

Avaliação da resitência à flexão, dureza e grau de conversão de compósitos para a técnica indireta em função da cor\" / Evaluation of resistance to bending, hardness, degree of conversion of composites for The technique indirect depending on color

Franco, Luciane de Lima 01 December 2005 (has links)
O objetivo do trabalho foi avaliar a resistência à flexão, microdureza e grau de conversão de 9 resinas compostas para uso indireto: Solidex (Sl), Epricord (Ep), Belleglass (Be), Signum (Sg), Sinfony (Sy), Tescera (Te), Cristobal (Cr), Targis (Ta) e Adoro (Ad); e uma resina para uso direto como controle, Esthet X (Et), em função da cor: esmalte (E), dentina (D) e translúcido (T). O teste de resistência à flexão (n=15) obedeceu ao método dos três pontos (Kratos) e, após a obtenção dos valores de carga, os corpos de prova fraturados eram posicionados em fita matriz de poliéster e fixados com resina quimicamente polimerizável (Adaptic) no paralelômetro. Em seguida, os corpos de prova eram levados ao microdurômetro (Shimadzu), para obtenção dos valores de microdureza Knoop (n=15), através da aplicação de uma carga de 50gramas por 30 segundos. Para o grau de conversão (n=3), os corpos eram construídos na mesma matriz usada para resistência à flexão, e posicionados em frente ao feixe de infravermelho do espectrofotômetro Raman (Bruker RFS 100/S - 64 scans) para leitura do grau de conversão. A análise de Variância e teste de Tukey foram usados para tratamento dos dados obtidos. A partir dos resultados, chegou-se às seguintes conclusões: 1. Resistência à flexão: O ranqueamento variou em função da cor e as resinas Cr, Sy, Be e Ta tiveram valores de resistência flexural estatisticamente superiores aos dos outros materiais. Os piores materiais foram o Ep, Sg e Sl. A cor não mostrou diferenças significantes (p=12), mas a interação (p<0,0001) e o material (p<0,0001) mostraram. Dois grupos intermediários entre estes foram encontrados. Um deles com valores muito próximos ao grupo com maiores médias de resistência flexural, os quais se encontram os materiais, Et e Te e, um terceiro grupo foi composto pelo material Ad. 2. Microdureza: As resinas Te > Cr > Be > Et, se destacaram com os maiores valores de dureza, (em ordem decrescente de valores de dureza, e com diferenças significantes entre elas). Os piores valores foram obtidos por Ad e Sy com diferenças significantes entre eles. Ep, Sg, Sl e Ta constituíram um grupo com valores intermediários. Portanto, o material (p<0,0001) e a interação (p<0,0001), obtiveram diferenças significantes. Em relação à cor (p<0,0002), a cor indicada para esmalte apresentou valores estatisticamente inferiores do que dentina e translúcido, e deve ser atribuída aos baixos valores em esmalte, em relação a outras cores do material Te. 3. Grau de conversão: Os maiores valores foram obtidos pelo material Te > Be > e = Cr > ou = Sy = Ad. Os materiais Ep e Ta apresentaram valores de grau de conversão logo abaixo destes materiais, e os piores valores de grau de conversão foram mensurados nos materiais Sg, Et e Sl, com diferenças estatisticamente significantes entre eles. Em relação à cor (p<0,0001), a cor indicada como translúcido apresentou valores estatisticamente superiores aos das duas outras cores. Estes resultados são devido aos altos valores apresentados pelos materiais Sy e Ep. Também tiveram valores significantemente diferentes o material (p<0,001) e a interação (p<0,0001). / Objectives: To characterize nine laboratory-processed composite systems (Adoro [Ad], Belleglass [Be], Cristobal [Cr], Epricord [Ep], Sinfony [Sy], Signum [Sg], Solidex [Si], Targis [Ta] andTescera [Te], ) and one composite for direct placement (Esthet-X [Et]) in terms of particle-size distribution and to compare the flexural strength (FS), Knoop hardness (KH) and degree of conversion (DC) of these composites. Materials and methods: Approximately 5 g of composite paste were dissolved in acetone pro analysi, mixed and centrifuged for 30 min at 3000 rpm. The remaining filler particles were dried (37 °C/12 h) and ultrasonically agitated. A computer-controlled apparatus using laser-diffraction technology was used to determine particle size distribution. Specimens (10 x 2 x 1 mm) were fractured with a 3-point bending test (n=15). KH was measured on fragments obtained after the flexural test (25g/30s). Raman spectra of both unpolymerized and polymerized resins were measured at room temperature in the backscattering geometry using the FT-Raman spectrometer. FS, KH and DC data were analyzed with one-way ANOVA and Tukey\'s post-hoc test (?=0.05). Results: The range of particle sizes was dramatically different for each composite. The composite Et showed the narrowest range of particle size while Sg showed the widest range. The highest DC means were observed for Te, Be and Cr. The lowest means were observed for Sg, Et and Si. Cr, Sy and Ta showed the highest FS values, while Ep, Sg and Si showed the lowest FS values. Te, Cr, Be and Et showed the highest KH means, while Ad and Sy the lowest. Conclusions: The composites Te, Cr and Be showed the best performance in all methods evaluated. On the other hand, the indirect composites Ep, Sg and Si demonstrated the worst performance.
118

Dimensionamento de pilares de concreto com seção transversal retangular usando envoltórias de momentos / Concrete columns design with rectangular cross section using envelopment of moments

Pinto, Vinicius Slompo 29 May 2017 (has links)
A ABNT NBR 6118:2014 &#8211; Projeto de Estruturas de Concreto apresenta quatro métodos para dimensionamento de pilares, sendo necessário o uso de envoltórias de momentos quando houver flexão composta oblíqua. Devido à complexidade, não se considera de forma adequada a não linearidade física, a verificação de flexão composta oblíqua e as imperfeições geométricas locais. Este trabalho apresenta diretrizes para o dimensionamento de pilares retangulares de concreto com armadura simétrica, submetidos à flexão composta oblíqua, empregando-se as envoltórias mínimas e resistentes para verificação da armadura. São feitas análises de como as não linearidades influem no estado-limite último de instabilidade e como elas devem ser consideradas nos métodos de dimensionamento. São indicadas duas situações que podem ser críticas para o pré-dimensionamento. São elaborados roteiros para determinação das envoltórias solicitantes, para cada método de dimensionamento, e das envoltórias resistentes, por meio do cálculo direto ou com o uso de ábacos para flexão composta normal. Há, também, dois apêndices, um sobre a determinação dos diagramas momento fletor &#8211; força normal &#8211; curvatura para qualquer tipo de seção, e outro sobre obtenção dos diagramas de interação (Nu, Mu), construção de ábacos para flexão composta normal e definição da taxa mecânica de armadura &#969;, sem o uso de ábacos para concretos de classe até C50. Concluindo, este trabalho constitui uma bibliografia atualizada para o projeto de pilares seguros e economicamente viáveis, esclarecendo conceitos tais como momento fletor resistente, envoltórias solicitantes e resistentes e utilização das não linearidades nos métodos de dimensionamento. / The Brazilian Code ABNT NBR 6118:2014 &#8211; Design of concrete structures presents four methods for columns dimensioning, requiring the use of envelopment of moments when there is biaxial bending. Due to complexity, do not accurately consider physical nonlinearity, biaxial bending and local geometric imperfections. This work presents guidelines for the design of concrete rectangular columns with symmetrical reinforcement, subjected to biaxial bending, employing the minimum and resisting envelopment curves for the verification of the reinforcement. Analysis are made of how nonlinearities influence in the ultimate limit state of instability and how they should be considered in design methods. Two situations are indicated that can be critical for the pre-dimensioning of the reinforcement. Procedures are developed to determine the envelopment of acting moments, for each design method, as well as the envelopment of resisting moments by means of either direct method or use of abacuses for eccentrical compression. There is also two appendixes, one about the determination of the diagrams bending moment &#8211; normal force &#8211; curvature for any kind of section, and another one about getting interaction diagrams (Nu, Mu), construction of abacuses for eccentrical compression and definition of &#969;, the reinforcement mechanical rate, without the use of abacuses for C50 concrete class or below. In conclusion, this constitutes an updated bibliography for the safe and economically viable columns project, clarifying concepts such as resistant moment, envelopments of acting and resisting moments, and the use of nonlinearities in the design methods.
119

Estruturas tipo sanduíche com placas de argamassa projetada / Sandwich-type structures with plates made of projected mortar

Bertini, Alexandre Araújo 22 February 2002 (has links)
Elementos tipo sanduíche, com placas de argamassa projetada, têm sido utilizados na construção de edificações em alguns países, inclusive no Brasil, apresentando boas características de resistência mecânica, térmica e acústica. De maneira geral, a aplicação desse tipo de elemento tem se restringido a obras de edificações, sendo utilizado principalmente como painéis de fechamento, portantes ou não, existindo ainda um potencial a ser explorado em obras de infra-estrutura, tais como: muros de arrimo, canais, galerias e reservatórios de água. Apesar de ser um método utilizado na construção de edificações, existem dúvidas, tais como: resistência efetiva da argamassa projetada, colaboração entre as placas resistentes em função do tipo de núcleo, modo de combater os efeitos de retração da argamassa, etc. Apresenta-se neste trabalho um estudo sobre a resistência efetiva da argamassa projetada, no qual se obteve que a sua resistência é de aproximadamente 80% da resistência à compressão de corpos-de-prova cilíndricos. Realizaram-se ainda ensaios para analisar a ligação entre elementos tipo sanduíche e seu comportamento à flexão, que comprovam o bom desempenho estrutural. Acredita-se que essa técnica de construção sanduíche possa ser aplicada em obras de infra-estrutura de interesse social, trazendo vantagens tecnológicas e econômicas em relação a sistemas tradicionais / Sandwich–type elements, with plates made of projected mortar, have been used in the construction of buildings in some countries, including Brazil, showing expressive thermical, acoustical and mechanical strength characteristics. In general, the application of this kind of element have been limited to buildings, mainly used as cladding panels, with carrying load capacity or not, and have other potential uses in infra-structural works to be explored such as bearing walls, channels, and water reservoirs. Although it is a method that have been conventionally applied in the construction of buildings, there are uncertainties in some parameters, like the effective strength of the projected mortar, interaction between the plates related to the type of core, the mode against shrinkage of the mortar etc. It is showed in this work a study concerning the effective strength of the projected mortar. As a result of a series of tests in walls made of projected mortar, it is determined that the effective strength of the projected mortar is 80% of that one measured from cylindrical specimens in compression tests. As well, some tests have been executed to analise the bending behaviour and the connections between the plates of the sandwich-type specimens, which demonstrated a relatively high structural performance. It is believed that this technical solution can be well applied to public works of social interest, and can offer technological and economical advantages in contrast to the traditional systems
120

Perfis de aço conformados a frio submetidos à flexão: análise teórico-experimental / Cold-formed steel members in flexure: theoretical-experimental analyses

Javaroni, Carlos Eduardo 10 December 1999 (has links)
Atualmente, os perfis de chapa dobrada têm encontrado intensa aplicação como elementos estruturais nas construções em aço e como consequência, estão sujeitos aos mais diversos tipos de carregamentos. Este trabalho apresenta os aspectos gerais do dimensionamento de perfis de chapa dobrada submetidos à flexão enquanto utilizados como vigas propriamente dito e, também, enquanto utilizados como terças. Analisam-se seções tipo U, tipo U enrijecido e tipo Z enrijecido. Os ensaios em perfis fletidos foram realizados sobre 3 diferentes condições de carregamento, com dois vãos distintos, em um total de sessenta e quatro perfis ensaiados. Para os perfis conectados às telhas de aço, os ensaios foram realizados em uma \"caixa de sucção\" desenvolvida especificamente para este projeto. Os perfis foram conectados às telhas pela mesa por meio de parafusos auto-brocantes, sendo realizados quinze ensaios. Os resultados dos ensaios são comparados com os resultados teóricos, resultados normatizados e resultados de alguns procedimentos aproximados. / Nowadays, the cold-formed steel members have intense application as structural elements in constructions and, in consequence, they are subjected to several types of loads. This work presents the general aspects of the study of cold-formed steel members subjected to flexion used as beams and, also, as purlins. Sections of type U, type C and type Z are analysed. The tests in beams were carried out under three different conditions of loads, with two distinct spans, in total of sixty four tests. For the purlins connected to roof system, the tests were in a \"suction box\", developed especially for this project. The purlins were connected to the roof system by the flange by using self-drilling screws, being carried out fifteen tests. The results of those tests are compared with the theoretical results, design specification provisions and results of some approximated procedures.

Page generated in 0.0289 seconds