• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 78
  • 6
  • 3
  • 2
  • 1
  • Tagged with
  • 90
  • 90
  • 59
  • 30
  • 28
  • 21
  • 20
  • 19
  • 18
  • 18
  • 18
  • 16
  • 16
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Processos de tratamento não convencionais para degradação do antibiótico sulfadiazina em meio aquoso. / Non-conventional treatment processes for the degradation of the antibiotic sulfadiazine in aqueous medium.

Arlen Mabel Lastre Acosta 25 April 2016 (has links)
A presença de antibióticos no meio ambiente aquático tem causado crescente preocupação mundial. Além dos relatos de resistência de bactérias a antibióticos, essa classe de fármacos também pode causar efeitos tóxicos e atuar como perturbadores endócrinos em diversos organismos vivos e, possivelmente, em humanos. Dentre os antibióticos comumente usados destacam-se as sulfonamidas, detectadas em águas subterrâneas e superficiais. Os processos avançados de oxidação (POA) têm sido apontados como tecnologias eficientes para tratamento de poluentes recalcitrantes em diferentes matrizes aquosas. Dentre os POA, o processo foto-Fenton é uma alternativa para a degradação de compostos não biodegradáveis, incluindo fármacos. Uma vez que a principal limitação do processo é o intervalo de pH (2,5- 4,0), a reação pode ser vantajosamente conduzida empregando-se substâncias bio-orgânicas solúveis (BOS) como agentes complexantes de Fe3+ em condições ligeiramente ácidas (pH 5). Por sua vez, o emprego da energia ultrassônica tem sido menos estudado. Nesse contexto, o objetivo deste trabalho é estudar a degradação do antibiótico sulfadiazina (SDZ) por meio do processo foto-Fenton na presença de substâncias bio-orgânicas solúveis (UVvis/ Fe3+/H2O2/BOS) e do processo de cavitação por meio de ultrassom (US). Os resultados obtidos mostram que a sulfadiazina é eficientemente degradada por ultrassom de alta frequência. As maiores porcentagens e taxas de remoção são obtidas usando menor frequência de operação (580 kHz), maior potência dissipada e em pH ligeiramente ácido (melhor condição: pH 5,5). Além disso, a reação de Fenton, combinada com o tratamento US, melhorou notavelmente a degradação da SDZ, particularmente quando quantidades extras de H2O2 foram adicionadas ao sistema. Por sua vez, o uso de BOS como aditivos no processo foto-Fenton apresenta influência marcante na fotodegradação da SDZ em condições ligeiramente ácidas (pH 5). Os BOS podem estabilizar espécies de ferro em solução aquosa em pH próximos ao neutro, o que constitui uma propriedade de grande interesse. Sob as condições estudadas, o BOS CVT230 foi mais eficiente do que FORSUD, provavelmente devido às diferenças nos grupos funcionais presentes na composição destas substâncias. Finalmente, foram calculados os indicadores de consumo de energia elétrica por ordem de grandeza (EEO) para o processo de ultrassom (1572 kW h m-3 ordem-1) e área do coletor por ordem de grandeza (ACO) para o processo foto-Fenton (8,07 m2 m-3 ordem-1). / The potential impacts of antibiotic residues in the environment have become an emerging concern during recent years due to their relation with the development of resistant bacteria, and in some cases to their ability to cause toxic and endocrine disrupting effects in humans and other living organisms. Highlighted among the commonly used antibiotics are the sulfonamides, detected in groundwater and surface water. Advanced oxidation processes (AOP) might constitute an important alternative to deal with pharmaceuticals degradation. Among them, the photo-Fenton process has been widely used. One of its major drawbacks is the highly acidic pH needed (2,5-4,0) to avoid the formation of photochemically inactive iron oxides and hydroxides. The ability of soluble bio-organic substances (SBO) to complex metal cations such as iron is useful for the development of photo-Fenton at mild acidic conditions (pH 5). In turn, the use of ultrasonic energy has been less studied. In this context, the aim of this work is to study the degradation of the antibiotic sulfadiazine (SDZ) by the photo-Fenton process in the presence of soluble bio-organic substances (UV-vis/Fe3+/H2O2/SBO) and by ultrasonic cavitation (US). The results confirm that SDZ is effectively degraded by highfrequency ultrasound. Higher SDZ percent removals and removal rates were observed for the lowest operating frequency (580 kHz), higher dissipated power, and in slightly acidic solution (pH 5.5). On the other hand, SDZ degradation is highly improved in the case of the US/ Fe(II)/H2O2 system. The use of the SBO as Fenton additives in turn has a remarkable influence in SDZ photodegradation at slightly acid conditions (pH 5). This could be ascertained to the complexation of iron by the SBO, hence maintained in the reaction medium as a photoactive species. Under the studied conditions, the BOS CVT230 was more efficient than FORSUD, probably due to differences in the functional groups present in the composition of these substances. Finally, the figures-of merit electrical energy per order (EEO) and collector area per order (ACO) were calculated for the ultrasound (1572 kW h m-3 ordem-1) and photo-Fenton (8,07 m2 m-3 ordem-1) processes respectively.
82

Βeta-bloqueadores em efluente hospitalar: ocorrência, degradação por processos avançados de oxidação e identificação de subprodutos / Βeta-blockers in hospital wastewater; occurence, degradation by advanced oxidation process and byproducts identification

Wilde, Marcelo Luís 15 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / β-Blockers are an important group of prescription drugs; as a consequence of the large and continuous use, they are commonly found in the environment. This study assessed, preliminary, the inherent risk of the β-blockers Atenolol, Metoprolol and Propranolol, mostly used in the University Hospital of Santa Maria (HUSM), and showed that Propranolol has high Risk Quotient (RQ) of 0.56. HPLC-FLD and SPE methodologies were developed and optimized with the aid of experimental design in order to analyze the occurrence of β-blockers in the HUSM sewage system. The average concentration for Atenolol, Metoprolol and Propranolol found for a week sampling were 2.45, 4.67 and 0.70 μg L-1 in the sewage of the Emergence; 0.95, 0.70 and 0.315 μg L-1 in the HUSM main sewage, and 1.26, 1.27 and 0.56 μg L-1 in the water course receptor, respectively, As possible remediation methodologies for the Hospital Wastewater (HWW) were investigated Advanced Oxidation Process (AOPs) such as photo-Fenton, K2FeO4, Ozonation and O3/Fe2+. The operational parameters were optimized by Response Surface Methodology (RSM). Using optimized conditions for photo-Fenton, Atenolol, Metoprolol and Propranolol were totally degraded in 5 min in aqueous solution, and the mineralization achieved 80% after 120 min of treatment. In HWW, the β-blockers were also totally degraded, however, only 26.5% of the organic matter and 38.6% of the aromaticity were removed. The ready biodegradability and toxicity of the photo-Fenton s samples were estimated by official methods, which indicated an increase in the biodegradability and toxicity. This behavior may be correlated to the formation of degradation products (DPs), relatively, more toxic. The DPs were identified with aid of Liquid Chromatography tandem Mass Spectrometry (LC-MSn). Other proposed degradation process was oxidation-coagulation using Fe(VI), which achieved above 90% degradation for Atenolol, Metoprolol and Propranolol in HWW, while only 17% COD and 60% aromaticity removal. In aqueous solution this process led to 71.7%, 24.7% and 96.5% degradation of Atenolol, Metoprolol and Propranolol, respectively. No mineralization was found, indicating the formation of DPs, identified by LC-MSn. The ready biodegradability of the post-process samples was tested and the results showed that the oxidation-coagulation with Fe(VI) increased the biodegradability. The applicability of ozonation was evaluated varying the pH (3-11) for HWW and aqueous solution. More than 95% of the β-blockers were degraded independently of the initial pH, while above 50% of the aromaticity was removed. In aqueous solution the β-blockers were degraded in 10 min treatment and the identification of the DPs were carried out for process pH 5, 7 and 9. Catalytic ozonation (O3/Fe2+) was applied to HWW and a mineralization of 49% was achieved, with 77.9% aromaticity removal. The β-blockers were totally degraded. Therefore, the present study represents a high qualified analytical information contribution concerning the occurrence of β-blockers in HWW. The studied AOPs/Fe(VI) processes demonstrated to be suitable to degrade Atenolol, Metoprolol and Propranolol. Moreover, high removal of organic matter and aromaticity were achieved by appling O3/Fe2+ process. In many aspects, this work can be considered original, in especial, by regarding the application of Ferrate(VI) and Catalytic Ozonation to the degradation of β-blockers in HWW. / Os β-bloqueadores são uma importante classe de fármacos prescritos na terapia de doenças cardiovasculares e como consequência de seu grande e contínuo uso são comumente encontrados no meio ambiente. O presente estudo avaliou preliminarmente o risco inerente dos β-bloqueadores mais usados no Hospital Universitário de Santa Maria (HUSM), Atenolol, Metoprolol e Propranolol, evidenciando que Propranolol apresentou maior risco inerente com Quociente de Risco teórico de 0,56 (risco médio). Métodos HPLC-FLD e de clean-up/pré-concentração por SPE foram desenvolvidos e otimizados com auxílio de Metodologia de Superfície de Resposta (RSM) para avaliar a ocorrência de β-bloqueadores no sistema de esgotos do HUSM. A concentração ambiental mensurada para Atenolol, Metoprolol e Propranolol durante um ciclo semanal no ponto de lançamento Efluente PA foi 2,45; 4,67 e 0,70 μg L-1, no ponto HUSM principal 0,95; 0,70 e 0,32 μg L-1 e para o Córrego onde os efluentes são lançados de 1,26; 1,27 e 0,56 μg L-1, respectivamente. Como metodologia de remediação da contaminação de β-bloqueadores em Efluente Hospitalar (EH) foram investigados os Processos Avançados de Oxidação (PAOs) Foto-Fenton, K2FeO4, Ozonização e O3/Fe2+. Os parâmetros operacionais foram otimizados por RSM. Usando as condições otimizadas para o processo Foto-Fenton, Atenolol, Metoprolol e Propranolol foram totalmente degradados em 120 min de tratamento, contudo somente 26,5 e 38,6% da carga orgânica e aromaticidade, respectivamente, foram removidos em EH. A pronta biodegradabilidade e toxicidade para amostras aquosas do processo Foto-Fenton foram analisadas por métodos oficiais e indicaram aumento na biodegradabilidade e toxicidade. Este comportamento esta relacionado à formação de Produtos de Degradação (PD) relativamente mais tóxicos. Os PDs foram identificados por Cromatografia Líquida acoplada a Espectrometria de Massas (LC-MSn). Outro processo proposto foi oxidação-coagulação com Fe(VI) que alcançou degradação de Atenolol, Metoprolol e Propranolol acima de 90% em EH, enquanto apenas 17 e 60% da matéria orgânica e aromaticidade foram removidos, respectivamente. Em solução aquosa este processo conduziu a degradação de 71,7; 24,7 e 96,5% de Atenolol, Metoprolol e Propranolol, respectivamente. Nenhuma mineralização foi encontrada indicando a formação de PDs, identificados por LC-MSn. A pronta biodegradabilidade para as amostras aquosas pós-processo foram avaliadas e os resultados encontrados mostraram que houve aumento na biodegradabilidade. A aplicabilidade de ozonização foi avaliada variando o pH de 3-11 em EH e solução aquosa. Mais de 95% dos β-bloqueadores foram degradados independente do pH inicial, enquanto mais de 50% da aromaticidade e 30% da matéria orgânica foram. Em solução aquosa todos os β-bloqueadores foram degradados em menos de 10 min e para os processos em pH 5, 7 e 9 foram identificados os PDs. O processo de O3/Fe2+ alcançou 49% de remoção de matéria orgânica, 77,9% de redução da aromaticidade e completa degradação de Atenolol, Metoprolol e Propranolol em EH. Portanto, o presente estudo contribui com informação analítica qualificada sobre a ocorrência de β-bloqueadores em EH. Os processos de degradação estudados mostraram-se adequados para a degradação de Atenolol, Metoprolol e Propranolol. Ademais, a maior remoção de matéria orgânica e aromaticidade foram observadas para o processo de O3/Fe2+. Em muitos aspectos, este trabalho pode ser considerado original, em especial sobre a aplicação de ferrato(VI) e ozonização catalítica para a degradação de β-bloqueadores em EH.
83

Heterogeneous photo-Fenton treatment of melanoidin wastewater at near neutral pH by ZnO@SnOx@nZVI catalyst on glass fiber / Heterogen foto-Fenton-behandling av avloppsvatten från melanoidin vid nära neutralt pH med ZnO@SnOx@nZVI-katalysator på glasfiber

Liu, You January 2024 (has links)
Melanoidin, a high molecular-weight heterogeneous pollutant in the effluents of molasses-using industries, poses a significant threat to the environment due to its non-biodegradability, unpleasant odour, and harmful effect. Various advanced oxidation processes (AOPs) that produce reactive oxygen species (ROS) are used for the degradation of melanoidins. Heterogeneous photo-Fenton process has emerged as a promising alternative approach in wastewater treatment owing to its enhanced catalytic activity, lower hydrogen peroxide (H2O2) consumption, and reusability of the catalyst. In this work, we investigated the photo-Fenton oxidation of melanoidins using heterogeneous catalyst ZnO@SnOx@nZVI supported on a flexible substrate. The effects of reaction pH, amount of catalyst and H2O2 on color and chemical oxygen demand (COD) removal, as well as the removal kinetics, were studied. It is found that the developed heterogeneous catalyst can lead to 97.3% decolorization of melanoidin (7000 COD) after 4 hours irradiation of simulated sunlight at pH 6 with a much lower dosage of H2O2 than the stoichiometric ratio with respect to COD. The generation of ·OH free radicals and residual H2O2 were monitored to understand the mechanism of melanoidin degradation at near-neutral pH with insufficient H2O2. The findings of this work have significant implications in treatment of non-biodegradable organic pollutants, owing to the advantages in avoiding low pH treatment condition, reducing the cost of H2O2, and enhanced chemical stability of photo-Fenton catalyst. / Melanoidin, en heterogen förorening med hög molekylvikt i avloppsvatten från industrier som använder melass, utgör ett betydande hot mot miljön på grund av dess icke-biologiska nedbrytbarhet, obehagliga lukt och skadliga effekt. Olika avancerade oxidationsprocesser (AOP) som producerar reaktiva syreföreningar (ROS) används för nedbrytning av melanoidiner. Heterogen foto-Fenton-process har framstått som ett lovande alternativ för avloppsrening på grund av dess förbättrade katalytiska aktivitet, lägre väteperoxid (H2O2) förbrukning och återanvändbarhet av katalysatorn. I detta arbete undersökte vi foto-Fenton-oxidationen av melanoidiner med hjälp av heterogen katalysator ZnO@SnOx@nZVI som stöds på ett flexibelt substrat. Effekterna av reaktionens pH, mängden katalysator och H2O2 på färg och avlägsnande av kemisk syreförbrukning (COD), liksom avlägsnandets kinetik, studerades. Det visade sig att den utvecklade heterogena katalysatorn kan leda till 97,3% avfärgning av melanoidin (7000 COD) efter 4 timmars bestrålning av simulerat solljus vid pH 6 med en mycket lågre dosering av H2O2 än det stökiometriska förhållandet med avseende på COD. Generering av ·OH fria radikaler och kvarvarande H2O2 övervakades för att förstå mekanismen för nedbrytning av melanoidin vid nära neutralt pH med otillräcklig H2O2. Resultaten av detta arbete har betydande konsekvenser vid behandling av icke- biologiskt nedbrytbara organiska föroreningar, på grund av fördelarna med att undvika behandlingsförhållanden med lågt pH, minska kostnaden för H2O2 och förbättrad kemiska stabilitet hos foto-Fenton-katalysatorn.
84

Efecto de distintas especies reactivas generadas fotoquímicamente sobre la eliminación de contaminantes presentes en aguas naturales

Gomis Vicens, Juan 15 June 2015 (has links)
[EN] In this Doctoral Thesis the reactivity of a group of emerging pollutants (EP) present in the output waters of urban treatment plants and the implementation of a photo-Fenton process in slightly acidic pH conditions using bio-organic solubles (SBO) as auxiliary chemicals have been studied. First, a mechanistic study was performed to investigate the role played by various reactive species in the oxidation of a mixture of emerging pollutants generated photochemically through advanced oxidation processes. These oxidizing species are the hydroxyl radical (OH), singlet oxygen (1O2) and the excited states of photocatalysts able to act through electron transfer processes. Results show that the EP degradation from the photo-Fenton process is too complex to be explained exclusively by the direct reaction of radical OH¿. More likely, OH radical reacts with further species present in the medium, so that long-lived radicals are generated and contribute to the degradation of EP or participate in chain processes. Rose bengal, known 1O2 generator, showed very low reactivity with EP under photochemical conditions. This fact together with the low values obtained for the rate constants in the reaction of 1O2 with EP, indicate that degradation of EP with singlet oxygen at these concentrations is very inefficient. Electron transfer processes studied using triphenylpyrylium (TPP+) and triphenylthiopyrylium (TPTP+) showed that degradation of EP were produced through the excited singlet and triplet states of the photocatalysts, slightly higher results were obtained by using the TPTP+. SBO, isolated from the wet fraction of municipal waste, are formed by a mixture of macromolecules with a wide range of sizes that goes from 67 to 463 kgmol-1. Furthermore, chemical composition of SBO resembles that of natural organic matter that has been employed in solar photochemical processes for wastewater treatment. Characterization of SBO has shown that these substances are biocompatible, stable after 24 hours of irradiation and able to improve the efficiency of photo-Fenton under slightly acidic pH. The results obtained in the optimization of the operational variables of the photo-Fenton process in the presence of SBO suggest that the mechanism of this process has changed, so that the optimum pH value of 2,8 has shifted to values close to 4. Therefore, the hydroxyl radical is not the main specie but others species could play a role; however they have not been unequivocally identified due to the complexity process. Moreover, SBO are able to generate reactive species; however their efficiency depends on the balance between the generation of reactive species and the inner filter effect produced by the deep color of SBO and also by the competition for the generated reactive species between SBO and the pollutants / [ES] En la presente Tesis Doctoral se estudió la reactividad de un conjunto de contaminantes emergentes (CE) presentes en aguas naturales de salida de depuradoras urbanas y la posibilidad de implementar un proceso foto-Fenton en condiciones de pH ligeramente ácidas empleando sustancias solubles bio-orgánicas (SBO) como auxiliares químicos. En primer lugar se realizó un estudio mecanístico para indagar sobre el papel desarrollado por diversas especies reactivas, generadas fotoquímicamente mediante procesos de oxidación avanzada, en la oxidación de una mezcla de contaminantes emergentes. Entre estas especies oxidantes se encuentra el radical hidroxilo (OH.), el oxígeno singlete (1O2), y los estados excitados de los fotocatalizadores capaces de actuar en procesos de transferencia electrónica. Los resultados obtenidos muestran que el proceso de degradación de los CE mediante foto-Fenton es demasiado complejo para poder ser explicado únicamente mediante la reacción directa del radical OH. Posiblemente, tras ser generado, el radical OH reacciona con las especies presentes en el medio de forma que se generan radicales de vida larga que contribuyen a la degradación de los CE o bien inicia procesos en cadena. El rosa de bengala, conocido generador de 1O2, mostró muy baja reactividad con los CE en condiciones fotoquímicas. Este hecho unido a los bajos valores obtenidos para las constantes de reacción del 1O2 con los CE, nos indica que la degradación mediante reacción con oxígeno singlete a estas concentraciones es muy ineficiente. Los estudios de los procesos de transferencia electrónica empleando trifenilpirilio (TPP+) y trifeniltiopirilio (TPTP+) muestran que la degradación de los CE se produce desde los estados excitados singlete y triplete de los fotocatalizadores, obteniéndose unos resultados ligeramente superiores mediante el empleo del TPTP+. Los SBO son materiales extraídos de la fracción húmeda de los residuos urbanos. Estas sustancias están constituidas por una mezcla de macromoléculas con un amplio rango de tamaños que oscila de 67 a 463 kgmol-1. Además su composición química presenta similitudes estructurales con algunas sustancias que se encuentran en la materia orgánica natural y que han sido empleadas en procesos fotoquímicos solares para el tratamiento de aguas residuales. La caracterización de los SBO ha demostrado que estas sustancias son biocompatibles, estables tras 24 horas de irradiación y capaces de mejorar la eficiencia del foto-Fenton en condiciones de pH ligeramente ácidas. Los resultados obtenidos en la optimización de las variables operacionales en el proceso foto-Fenton en presencia de SBO sugieren que se ha producido una modificación en el mecanismo del proceso foto-Fenton de forma que se ha desplazado el valor óptimo de pH desde 2,8 a valores cercanos a 4. Por tanto el radical hidroxilo puede no ser la especie principal y entrar en juego otras especies que no han podido ser identificadas con certeza debido a la complejidad del proceso. Los SBO son capaces de generar especies reactivas, sin embargo se ha de llegar a un equilibrio entre la generación de especies reactivas y el efecto filtro producido por su acusada coloración, así como por la competencia de los propios SBO por las especies reactivas generadas. / [CA] En la present Tesi Doctoral es va estudiar la reactivitat d'un conjunt de contaminants emergents (CE) presents en aigües d'eixida de depuradores urbanes i la possibilitat d'implementar un procés foto-Fenton en condicions de pH lleugerament àcides emprant substàncies solubles bio-orgàniques (SBO) com auxiliars químics. En primer lloc es va realitzar un estudi mecanístic per indagar sobre el paper desenvolupat per diverses espècies reactives, generades fotoquímicament mitjançant processos d'oxidació avançada, en l'oxidació d'una mescla de contaminants emergents. Entre aquestes espècies oxidants es troba el radical hidroxil (OH), l'oxigen singlet (1O2), i els estats excitats dels fotocatalitzadors capaços de actuar per processos de transferència electrònica. Els resultats obtinguts mostren que el procés de degradació dels CE mitjançant foto-Fenton és massa complex per poder ser explicat únicament per la reacció directa del radical OH. Possiblement després de ser generat, el radical OH reacciona amb les espècies presents en el medi de manera que es generen radicals de vida llarga que contribueixen a la degradació dels CE o bé inicia processos en cadena. El rosa de bengala, conegut generador de 1O2, va mostrar molt baixa reactivitat amb els CE en condicions fotoquímiques. Aquest fet unit als baixos valors obtinguts per a les constants de reacció del 1O2 amb els CE, ens indica que la degradació mitjançant reacció amb oxigen singlet a aquestes concentracions és molt ineficient. Els estudis dels processos de transferència electrònica utilitzant trifenilpirili (TPP+) i trifeniltiopirili (TPTP+) mostren que la degradació dels CE es produeix per mitjà dels estats excitats singlet i triplet dels fotocatalitzadors, obtenint uns resultats lleugerament superiors mitjançant l'ús del TPTP+. Els SBO són materials obtinguts de la fracció humida dels residus urbans. Aquestes substàncies estan constituïdes per una barreja de macromolècules amb un ampli rang de pesos moleculars que van de 67 a 463 kgmol-1. A més la seva composició química presenta similituds estructurals amb algunes substàncies que es troben en la matèria orgànica natural i que han sigut utilitzades en processos fotoquímics solars per al tractament d'aigües residuals. La caracterització dels SBO ha demostrat que aquestes substàncies són biocompatibles, estables després de 24 hores d'irradiació i son capaços de millorar l'eficiència del foto-Fenton en condicions lleugerament àcides. Els resultats obtinguts en l'optimització de les variables operacionals en el procés foto-Fenton en presència de SBO semblen suggerir que s'ha produït una modificació en el mecanisme de manera que s'ha desplaçat el valor òptim de pH des 2,8 a valors propers a 4. Pertant el radical hidroxil deixa de ser l'espècie principal i entren en joc altres espècies que no han pogut ser identificades amb certesa a causa de la complexitat del procés. Els SBO són capaços de generar espècies reactives, però s'ha d'arribar a un equilibri entre la generació d'espècies reactives i l'efecte filtre produït per la seua acusada coloració, així com per la competència dels propis SBO per les espècies reactives generades. / Gomis Vicens, J. (2015). Efecto de distintas especies reactivas generadas fotoquímicamente sobre la eliminación de contaminantes presentes en aguas naturales [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/51667
85

Proceso foto-Fenton como una alternativa en la degradación de microplásticos de poliamida presentes en aguas residuales textiles

Marcelino Pérez, Edgar 16 January 2023 (has links)
[ES] La alta escasez de agua y el constante incremento en la industrialización ha propiciado el deterioro de las reservas de agua como consecuencia de la excesiva generación y liberación de desechos contaminantes. Actualmente, se han reportado una gran variedad de contaminantes de diferente naturaleza, entre ellos se pueden mencionar los microplásticos (MPs) que han sido detectados en agua potable e incluso en animales para la ingesta humana lo cual puede acarrear graves problemas de salud. Cabe mencionar que uno de los mayores problemas a nivel medioambiental de los MPs radica en su alta estabilidad, ya que los métodos habituales utilizados para la eliminación de contaminantes no ejercen efecto. En este sentido, los Procesos de Oxidación Avanzada (POAs) han surgido como una alternativa a la eliminación de contaminantes de difícil degradación, debido a la generación principalmente de radicales hidroxilo que tienen un elevado potencial de oxidación y son muy poco selectivos. En este trabajo nos hemos centrado en el uso del proceso foto-Fenton, con sales de hierro y peróxido de hidrógeno e utilizando la luz solar como fuente de radiación, para llevar a cabo la degradación de MPs, específicamente la poliamida 6,6 (PA66), a pesar de que este polímero no es propiamente un plástico, la literatura lo considera dentro de ellos debido a su importancia como contaminante. A partir de PA66 obtenida de la industria textil, se evaluó el proceso de degradación con distintas técnicas y métodos analíticos destacando entre ellos la microscopía FESEM y la espectroscopía TF-IR. Se realizaron estudios en simulador solar en condiciones habituales de trabajo de procesos foto-Fenton (5 mg/L de Fe, 10 mg/L de H2O2 y pH = 2.8) y qué efectos podían producir tanto el tiempo de radiación como la presencia de una matriz natural como la salinidad en las aguas de tratamiento. Además, se realizaron estudios para confirmar que el proceso de degradación de la PA66 observado (numerosas imperfecciones aparecieron en la superficie del microplástico) era debido a la acción tanto del radical hidroxilo como del radical superóxido utilizando secuestrantes de ambos y comparando los procesos. Posteriormente se evaluó la degradación de la PA66 a nivel planta piloto utilizando dos diferentes fuentes de irradiación: LED vis y LED vis + solar realizando para ello, un estudio previo de diseño de experimentos tipo Doehlert para minimizar recursos y residuos y obtener las óptimas condiciones de tratamiento de la PA66 y, con base a estas condiciones se comparó la degradación de 4 diferentes MPs: PA66, poliamida 6 (PA6), aramida y poliéster (PES). Por último, se estudió la degradación de la PA66 bajo estas mismas condiciones en un periodo de 100 h. Los estudios de estabilidad mostraron que la PA66 no presenta fotólisis ni hidrólisis y los ensayos de degradación mediante el proceso foto-Fenton en un periodo de 7 h mostraron la formación de defectos sobre la superficie de la PA66 y disminución de grupos funcionales de acuerdo microscopia FESEM y FTIR, asimismo, el MP mostró cambios en su punto de fusión a diferentes tiempos de tratamiento como consecuencia de la rotura de las cadenas del polímero. Este mismo efecto se observó en un tiempo de degradación de 100 h de la PA66 con un aumento en el número y diámetro de defectos formados. La adición de NaCl a 30 g/L (alta salinidad) provocó una disminución en el daño generado debido a la reacción de los radicales hidroxilo y formación de especies reactivas con menor potencial de oxidación. La adición de 2-propanol y p-benzoquinona como atrapadores del radical hidroxilo y anión superóxido corroboraron esta suposición. La PA66 tratada en planta piloto mediante el uso de radiación LED vis + solar presentó un mayor grado de degradación en comparación con la tratada únicamente con radiación LED vis (incremento de 90 veces más el área superficial especifica de la PA66 tratada con respecto a la PA66 sin tratamiento). / [CA] L'alta escassetat d'aigua i el constant increment en la industrialització ha propiciat la deterioració dels cossos d'aigua a conseqüència de l'excessiva generació i alliberament de deixalles contaminants. Actualment, s'han reportat una gran varietat de contaminants de diferent naturalesa, entre ells es poden esmentar els microplàstics (MPs) que han sigut detectats en aigua potable i fins i tot en animals per a la ingesta humana la qual cosa pot implicar greus problemes de salut. Cal esmentar que un dels majors problemes a nivell mediambiental dels MPs radica en la seua alta estabilitat, ja que els mètodes habituals utilitzats per a l'eliminació de contaminants no exerceixen cap efecte. En aquest sentit, els Processos d'Oxidació Avançada (POAs) han sorgit com una alternativa a l'eliminació de contaminants de difícil degradació, a causa de la generació principalment de radicals hidroxil que tenen un elevat potencial d'oxidació i són molt poc selectius. En aquest treball ens hem centrat en l'ús del procés foto-Fenton, amb sals de ferro i peròxid d'hidrogen e utilitzant la llum solar com a font de radiació, per a dur a terme la degradació de MPs, específicament la poliamida 6,6 (PA66). A partir de PA66 obtinguda de la indústria tèxtil, es va avaluar el procés de degradació amb diferents tècniques i mètodes analítics destacant entre ells la microscòpia FESEM i la espectroscopía FT-IR. Es van realitzar estudis en simulador solar en condicions habituals de treball de processos foto-Fenton (5 mg/L de Fe, 10 mg/L de H2O2 i pH = 2.8) i quins efectes podien produir tant el temps de radiació com la presència d'una matriu natural com la salinitat en les aigües de tractament. A més, es van realitzar estudis per a confirmar que el procés de degradació de la PA66 observat (nombroses imperfeccions van aparèixer en la superfície del microplàstic) era degut a l'acció tant del radical hidroxil com del radical superòxid utilitzant segrestants de tots dos i comparant els processos. Posteriorment es va avaluar la degradació de la PA66 a nivell planta pilot utilitzant dues diferents fonts d'irradiació: LED vis i LED-vis + solar realitzant per a això, un estudi previ de disseny d'experiments tipus Doehlert per a minimitzar recursos i residus i obtindre les òptimes condicions de tractament de la PA66 i, amb base a aquestes condicions es va comparar la degradació de 4 diferents MPs (PA66, PA6, Aramida i PES). Finalment, es va estudiar la degradació de la PA66 sota aquestes mateixes condicions en un període de 100 h. Els estudis d'estabilitat van mostrar que la PA66 no presenta fotòlisis ni hidròlisi i els assajos de degradació mitjançant el procés foto-Fenton en un període de 7 h van mostrar la formació de defectes sobre la superfície de la PA66 i disminució de grups funcionals d'acord microscòpia FESEM i FT-IR, així mateix, el MP va mostrar canvis al punt de fusió a diferents temps de tractament a conseqüència del trencament de les cadenes del polímer. Aquest mateix efecte es va observar en un temps de degradació de 100 h de la PA66 amb un augment en el nombre de defectes formats i diàmetre dels defectes. L'addició de NaCl a 30 g/L (alta salinitat) va provocar una disminució en el mal generat a causa del secuestrament dels radicals hidroxil i formació d'espècies reactives amb menor potencial d'oxidació. L'addició de 2-propanol i p-benzoquinona com atrapadores del radical hidroxil i anió superòxid van corroborar aquesta suposició. La PA66 tractada en planta pilot mitjançant l'ús de radiació LED-vis + solar va presentar un major grau de degradació en comparació amb la tractada únicament amb radiació LED-vis (increment de 90 vegades més l'àrea superficial especifica de la PA66 tractada respecte a la PA66 sense tractament). L'avaluació de la degradació dels 4 MPs va mostrar que el PES i la aramida no són degradables en aquestes condicions i la PA6 va presentar una menor degradació que la PA66. / [EN] The high scarcity of water and the constant increase in industrialization has led to the deterioration of water bodies as a consequence of the excessive generation and release of pollutant wastes. Currently, a great variety of pollutants of different nature have been reported, among them we can mention microplastics (MPs) that have been detected in drinking water and even in animals for human consumption, which can cause serious health problems. It is worth mentioning that one of the biggest environmental problems of MPs lies in their high stability, since the usual methods used for the elimination of contaminants have no effect. In this sense, Advanced Oxidation Processes (AOPs) have emerged as an alternative for the removal of pollutants that are difficult to degrade, mainly due to the generation of hydroxyl radicals that have a high oxidation potential and are not very selective. In this work we have focused on the use of the photo-Fenton process, with iron salts and hydrogen peroxide and using sunlight as a source of radiation, to carry out the degradation of PMs, specifically polyamide 6,6 (PA66), despite that this polymer is not a plastic, literature considers it among them due to its importance as a pollutant. Using PA66 obtained from the textile industry, the degradation process was evaluated with different techniques and analytical methods, among them FESEM microscopy and TF-IR spectroscopy. Studies were carried out in a solar simulator under usual working conditions of photo-Fenton processes (5 mg/L Fe, 10 mg/L H2O2 and pH = 2.8) and it was studied the effect by the radiation time and the presence of a natural matrix such as salinity in the treatment water. In addition, studies were conducted to confirm that the PA66 degradation process observed (numerous imperfections appeared on the surface of the microplastic) was due to the action of both oxygen species (hydroxyl radical and the superoxide radical) by using scavengers of both and comparing the processes. Subsequently, PA66 degradation was evaluated at pilot plant level using two different irradiation sources: LED vis and LED vis + solar, a previous study of Doehlert type design of experiments to minimize resources and waste and obtain the optimal conditions for PA66 treatment and, based on these conditions the degradation of 4 different MPs: PA66, polyamide 6 (PA6), aramid and polyethylene (PES) was compared. Finally, the degradation of PA66 under these same conditions was studied over a period of 100 h. The stability studies showed that PA66 does not present photolysis or hydrolysis and the degradation tests by the photo-Fenton process in a period of 7 h showed the formation of defects on the surface of PA66 and decrease of functional groups according to FESEM and FTIR microscopy, also, the MP showed changes in its melting point at different treatment time as a result of the breaking of the polymer chains. This same effect was observed at a degradation time of 100 h of PA66 with an increase in the number of defects formed and in their diameters. The addition of NaCl at 30 g/L (high salinity) caused a decrease in the damage generated due to the reaction of hydroxyl radicals and formation of reactive species with lower oxidation potential. The addition of 2-propanol and p-benzoquinone as hydroxyl radical and superoxide anion scavengers corroborated this assumption. PA66 treated in pilot plant using LED vis + solar irradiation showed a higher degree of degradation compared to PA66 treated only with LED vis irradiation (90-fold increase in the specific surface area of treated PA66 with respect to untreated PA66). The evaluation of the degradation of the 4 MPs showed that PES and aramid are not degradable under these conditions and PA6 presented a lower degradation than PA66. / Marcelino Pérez, E. (2022). Proceso foto-Fenton como una alternativa en la degradación de microplásticos de poliamida presentes en aguas residuales textiles [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/191335
86

Estudo da degradação de corante têxtil em matrizes aquosas por meio dos processos oxidativos avançados O3-H2O2/UV e foto-Fenton. / Study on the degradation of a textile dye in aqueous matrices by the oxidative processes O3-H2O2/UV and photo-Fenton.

Santana, Caroline Martins 04 December 2009 (has links)
A indústria têxtil gera grandes volumes de efluentes com elevada carga orgânica, forte coloração e toxicidade. Neste trabalho, estuda-se o tratamento de solução aquosa contendo o corante Solophenyl Yellow Arle 154% por meio dos processos O3-H2O2/UV e foto-Fenton, avaliando-se as repostas: remoção de cor em 5 minutos, remoção de cor em 60 minutos, taxa máxima de remoção de cor e remoção de COT em 60 minutos. Os experimentos foram realizados em semibatelada com circulação usando um reator fotoquímico com campo de radiação anular coaxial, constituído de corpo cilíndrico em aço com refletor interno de alumínio para 12 lâmpadas fixadas simetricamente na superfície refletora e um tubo reator em quartzo de 0,7 L, posicionados verticalmente no eixo do refletor. Para o processo O3-H2O2/UV foram utilizadas lâmpadas Phillips TUV (36 W, 254 nm). A corrente gasosa contendo O3 foi introduzida no reator por meio de um difusor. Para o processo foto-Fenton foram utilizadas lâmpadas Sylvania (12 W cada, 300 400 nm) e concentração de Fe(II) de 0,25 mmol/L. Em ambos os processos, solução de peróxido de hidrogênio foi adicionada durante os 30 minutos iniciais de tratamento. As amostras foram analisadas por medidas de carbono orgânico total (COT) e remoção de cor (absorbância medida em 405 nm em espectrofotômetro UV-visível). Em ambos os processos utilizou-se o planejamento experimental Doehlert, definindo os valores mínimo e máximo para cada variável adotada. No caso do processo O3- H2O2/UV (ETAPA I), foram estudados os efeitos da potência elétrica total das lâmpadas (144 432 W), concentração de H2O2 (5 30 mmol/L), concentração inicial de corante (20 100 mg/L), concentração de ozônio (10 40 mg/L) e pH (3 10). No processo foto-Fenton (ETAPA II), estudaram-se os efeitos da potência (160 480 W), concentração de H2O2 (5 30 mmol/L) e concentração inicial de corante (20 100 mg/L). Os resultados da ETAPA I indicaram que o aumento da concentração do corante, em meio ácido, aumenta a remoção de cor em 5 e 60 minutos, sugerindo a eficiência da ação via ozônio molecular sob o grupo cromóforo do corante. Os melhores resultados apresentaram remoção acima de 95% em 5 e 60 minutos de tratamento. Entretanto, para a remoção de COT em 60 minutos o processo não foi eficiente, apresentando resultado máximo de 35,6%. Na ETAPA II obtiveram-se resultados menos satisfatórios para remoção de cor se comparados aos da ETAPA I (56,1% em 5 minutos e 78% em 60 minutos de tratamento), mas melhores em relação à remoção de COT em 60 minutos atigindo 45,1% de remoção. As maiores taxas de remoção de cor foram observadas nos 5 primeiros minutos de tratamento para todos os experimentos. Experimentos complementares realizados em uma terceira etapa (ETAPA III) mostraram que a aplicação do processo O3 seguido do processo foto-Fenton permitiu resultados satisfatórios tanto para remoção de cor (97,2%), quanto para remoção de COT (69,5%). O estudo da ação do processo O3 em modo contínuo e a avaliação econômica preliminar do processo integrado O3 - foto-Fenton sugerem o potencial de aplicação do tratamento integrado a indústrias têxteis. / The textile industry generates large volumes of wastewater with high organic load, strong coloration and toxicity. In this work, the treatment of an aqueous solution containing the dye Solophenyl Yellow Arle 154% was studied by the O3-H2O2/UV and photo-Fenton processes, in order to evaluate the responses color removal after 5 minutes; color removal after 60 minutes; maximum rate of color removal; and TOC removal after 60 minutes. The experiments were carried out in the semi-batch mode with circulation using a photochemical reactor with annular coaxial radiation field, consisting of a cylindrical stainless steel support with an aluminum internal reflector with 12 lamps fixed symmetrically in the internal reflecting surface, and a quartz tube reactor of 0.7 L, positioned vertically along the axis of the reflector. For the O3- H2O2/UV process, Phillips TUV lamps (36 W, 254 nm) were used; the gas stream containing zone was introduced into the reactor through a diffuser. For the photo- Fenton process, Sylvania lamps (12 W each, 300 - 400 nm) and a concentration of Fe (II) of 0.25 mmol/L were used. In both cases, the hydrogen peroxide solution was added in the first 30 minutes of treatment. The samples were analyzed by the measurement of total organic carbon (TOC) and color removal (absorbance measured at 405 nm in a UV-visible spectrophotometer). In both cases the Doehlert experimental design was used, defining the minimum and maximum values of each variable adopted. In the case of O3-H2O2/UV process (PHASE I), the effects of the total electric power of the lamps (144 - 432 W), H2O2 concentration (5 - 30 mmol/L), initial dye concentration (20 - 100 mg/L), ozone concentration (10 - 40 mg/L), and pH (3 - 10) were studied. For the photo-Fenton process, the studied variables were: total electric power of the lamps (160 - 480 W), H2O2 concentration (5 - 30 mmol/L), and initial dye concentration (20 - 100 mg/L). The results of PHASE I indicated that the increase of dye concentration in acidic conditions increases color removal after 5 and 60 minutes, thus suggesting the efficiency of molecular ozone action upon the chromophore group of the dye. The best results showed color removal above 95% after 5 and 60 minutes of treatment. However, for the TOC removal the process was not efficient, with maximum removal after 60 minutes of only 35.6%. In PHASE II less satisfactory results for color removal were obtained in comparison with PHASE I (56.1% after 5 minutes and 78% after 60 minutes of treatment), but with higher TOC removal after 60 minutes, achieving over 45.1%. The highest color removal rates were observed within the first 5 minutes of treatment for all runs. Additional experiments carried out in PHASE III showed that the oxidation by O3 followed by the photo-Fenton process enabled to achieve suitable results for both color (97.2%) and TOC removals (69.5%). The study of the O3 process in the continuous mode and a preliminary economic evaluation suggests a high potential for the use of the integrated O3-photo-Fenton process in textile industries.
87

Estudo da degradação de corante têxtil em matrizes aquosas por meio dos processos oxidativos avançados O3-H2O2/UV e foto-Fenton. / Study on the degradation of a textile dye in aqueous matrices by the oxidative processes O3-H2O2/UV and photo-Fenton.

Caroline Martins Santana 04 December 2009 (has links)
A indústria têxtil gera grandes volumes de efluentes com elevada carga orgânica, forte coloração e toxicidade. Neste trabalho, estuda-se o tratamento de solução aquosa contendo o corante Solophenyl Yellow Arle 154% por meio dos processos O3-H2O2/UV e foto-Fenton, avaliando-se as repostas: remoção de cor em 5 minutos, remoção de cor em 60 minutos, taxa máxima de remoção de cor e remoção de COT em 60 minutos. Os experimentos foram realizados em semibatelada com circulação usando um reator fotoquímico com campo de radiação anular coaxial, constituído de corpo cilíndrico em aço com refletor interno de alumínio para 12 lâmpadas fixadas simetricamente na superfície refletora e um tubo reator em quartzo de 0,7 L, posicionados verticalmente no eixo do refletor. Para o processo O3-H2O2/UV foram utilizadas lâmpadas Phillips TUV (36 W, 254 nm). A corrente gasosa contendo O3 foi introduzida no reator por meio de um difusor. Para o processo foto-Fenton foram utilizadas lâmpadas Sylvania (12 W cada, 300 400 nm) e concentração de Fe(II) de 0,25 mmol/L. Em ambos os processos, solução de peróxido de hidrogênio foi adicionada durante os 30 minutos iniciais de tratamento. As amostras foram analisadas por medidas de carbono orgânico total (COT) e remoção de cor (absorbância medida em 405 nm em espectrofotômetro UV-visível). Em ambos os processos utilizou-se o planejamento experimental Doehlert, definindo os valores mínimo e máximo para cada variável adotada. No caso do processo O3- H2O2/UV (ETAPA I), foram estudados os efeitos da potência elétrica total das lâmpadas (144 432 W), concentração de H2O2 (5 30 mmol/L), concentração inicial de corante (20 100 mg/L), concentração de ozônio (10 40 mg/L) e pH (3 10). No processo foto-Fenton (ETAPA II), estudaram-se os efeitos da potência (160 480 W), concentração de H2O2 (5 30 mmol/L) e concentração inicial de corante (20 100 mg/L). Os resultados da ETAPA I indicaram que o aumento da concentração do corante, em meio ácido, aumenta a remoção de cor em 5 e 60 minutos, sugerindo a eficiência da ação via ozônio molecular sob o grupo cromóforo do corante. Os melhores resultados apresentaram remoção acima de 95% em 5 e 60 minutos de tratamento. Entretanto, para a remoção de COT em 60 minutos o processo não foi eficiente, apresentando resultado máximo de 35,6%. Na ETAPA II obtiveram-se resultados menos satisfatórios para remoção de cor se comparados aos da ETAPA I (56,1% em 5 minutos e 78% em 60 minutos de tratamento), mas melhores em relação à remoção de COT em 60 minutos atigindo 45,1% de remoção. As maiores taxas de remoção de cor foram observadas nos 5 primeiros minutos de tratamento para todos os experimentos. Experimentos complementares realizados em uma terceira etapa (ETAPA III) mostraram que a aplicação do processo O3 seguido do processo foto-Fenton permitiu resultados satisfatórios tanto para remoção de cor (97,2%), quanto para remoção de COT (69,5%). O estudo da ação do processo O3 em modo contínuo e a avaliação econômica preliminar do processo integrado O3 - foto-Fenton sugerem o potencial de aplicação do tratamento integrado a indústrias têxteis. / The textile industry generates large volumes of wastewater with high organic load, strong coloration and toxicity. In this work, the treatment of an aqueous solution containing the dye Solophenyl Yellow Arle 154% was studied by the O3-H2O2/UV and photo-Fenton processes, in order to evaluate the responses color removal after 5 minutes; color removal after 60 minutes; maximum rate of color removal; and TOC removal after 60 minutes. The experiments were carried out in the semi-batch mode with circulation using a photochemical reactor with annular coaxial radiation field, consisting of a cylindrical stainless steel support with an aluminum internal reflector with 12 lamps fixed symmetrically in the internal reflecting surface, and a quartz tube reactor of 0.7 L, positioned vertically along the axis of the reflector. For the O3- H2O2/UV process, Phillips TUV lamps (36 W, 254 nm) were used; the gas stream containing zone was introduced into the reactor through a diffuser. For the photo- Fenton process, Sylvania lamps (12 W each, 300 - 400 nm) and a concentration of Fe (II) of 0.25 mmol/L were used. In both cases, the hydrogen peroxide solution was added in the first 30 minutes of treatment. The samples were analyzed by the measurement of total organic carbon (TOC) and color removal (absorbance measured at 405 nm in a UV-visible spectrophotometer). In both cases the Doehlert experimental design was used, defining the minimum and maximum values of each variable adopted. In the case of O3-H2O2/UV process (PHASE I), the effects of the total electric power of the lamps (144 - 432 W), H2O2 concentration (5 - 30 mmol/L), initial dye concentration (20 - 100 mg/L), ozone concentration (10 - 40 mg/L), and pH (3 - 10) were studied. For the photo-Fenton process, the studied variables were: total electric power of the lamps (160 - 480 W), H2O2 concentration (5 - 30 mmol/L), and initial dye concentration (20 - 100 mg/L). The results of PHASE I indicated that the increase of dye concentration in acidic conditions increases color removal after 5 and 60 minutes, thus suggesting the efficiency of molecular ozone action upon the chromophore group of the dye. The best results showed color removal above 95% after 5 and 60 minutes of treatment. However, for the TOC removal the process was not efficient, with maximum removal after 60 minutes of only 35.6%. In PHASE II less satisfactory results for color removal were obtained in comparison with PHASE I (56.1% after 5 minutes and 78% after 60 minutes of treatment), but with higher TOC removal after 60 minutes, achieving over 45.1%. The highest color removal rates were observed within the first 5 minutes of treatment for all runs. Additional experiments carried out in PHASE III showed that the oxidation by O3 followed by the photo-Fenton process enabled to achieve suitable results for both color (97.2%) and TOC removals (69.5%). The study of the O3 process in the continuous mode and a preliminary economic evaluation suggests a high potential for the use of the integrated O3-photo-Fenton process in textile industries.
88

Aplicação dos processos foto-Fenton e eletrofloculação no tratamento de efluente de curtume / Application of the photo-Fenton and electrocoagulation processes at the tannery effluent treatment

Borba, Fernando Henrique 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:12Z (GMT). No. of bitstreams: 1 Fernando Henrique Borba.pdf: 3301834 bytes, checksum: 0c5216d667957cc99d5acd2dd5d59c05 (MD5) Previous issue date: 2010-02-18 / Pollution is a currently environmental problem of world concern. There are many events such as the discharging of untreated effluents in watercourses that cause the eutrophization of water bodies and bad water quality, as well as an inefficiency or lack of a current environmental law. The main goal of this dissertation was the application of solar and artificial-based photo-Fenton processes and aluminum electrodes-based electrocoagulation method in non coupled mode and in an integrated mode for the tannery effluent treatment. These effluent treatments were carried out in lab-scale reactors. In order to evaluate the performance of the reactor experimental conditions of photo-Fenton reactor, a 33 complete experimental design was performed. The lab scale EC reactor was operated at the 4 A electrical current, 4 cm electrode distance and 3 initial pH optimized values, according to the previous results obtained in another work, while the electrolysis time was varied from 5 to 120 min. For EC and photo-Fenton reactors, their performance was evaluated on the removal values of chemical oxygem demand (COD), color, turbidity, total solids (TS), total fixed solids (TFS), total volatile solids (TVS) and metal concentration. Measurements of physico-chemical parameters for untreated and treated effluent samples were performed applying the Standard Method for water analysis, while metal concentrations were determined by the Synchrotron radiation total Reflexion X-ray Fluorescence technique at Brazilian Light Synchrotron Laboratory. By an optimized photon-Fenton process at 0.5 g Fe2+ L-1, 30 g H2O2 L-1, 3 initial pH, and 120 min reaction time, tannery effluent was treated achieving a high performance in pollutant removal as reported by 98.1, 96.4, 98.8, 71.8, 32.1 and 98.5 percent removal for COD, color, turbidity, TS, TFS, and TVS, respectively. As a primer treatment stage, electrocoagulation technique was not achieved a well successful result based on the physico-chemical parameter values reduction as compared with photo-Fenton process. However, an integrated solar irradiation-based photo-Fenton and Al electrodes-based electrocoagulation with 15 min electrolysis time has achieved recommended values by the Brazilian environmental law for Cr concentration (0.24 mg Cr L-1) and DQO (107 mg O2 L-1). Considering both the costs of electrical energy and material and the generated sludge discharging, one m3 of tannery effluent should cost R$ 56.30 for a treatment system based on an integrated and optimized photo Fenton and electrocoagulation processes. Finally, the integrated solar-based photo Fenton and electrocoagulation method is suggested as an efficient one, instead to apply a unique process. / A poluição ambiental é um dos grandes problemas nos países desenvolvidos e em desenvolvimento. Isto é decorrente de uma série de fatores, como o despejo de efluentes não tratados em corpos hídricos e a ineficiência e/ou a falta de legislação ambiental vigente. O objetivo principal deste trabalho é aplicar os processos foto-Fenton com irradiação solar e/ou artificial, a técnica da eletrofloculação e a integração destes processos no tratamento de efluente de curtume. Ambos os processos de tratamento do foto-Fenton e da eletrofloculação foram conduzidos em reatores a escala laboratorial. Para a técnica da eletrofloculação foi utilizado um par de placas de alumínio como eletrodos no reator de eletrofloculação. Para avaliar as melhores condições de processo do sistema foto-Fenton, foi aplicado um planejamento experimental 33 completo. Para a técnica da eletrofloculação manteve-se constante a intensidade de corrente, pH inicial do efluente bruto e distância entre os eletrodos, variando-se o tempo de eletrólise de 5 à 120 min. A eficiência de ambos os processos foram avaliadas com base na redução de Demanda química de oxigênio (DQO), cor, turbidez, sólidos totais (ST), sólidos totais fixos (STF), sólidos totais voláteis (STV). Para a técnica da eletrofloculação e dos processos integrados também foram avaliados a redução da concentração dos metais pesados. Todas as medidas dos parâmetros físico-químicos foram realizadas aplicando os métodos padrões do Standard Methods for the Examination of Water and Wastewater para amostra não tratada e tratada. As concentrações dos metais pesados foram determinadas usando a técnica de fluorescência de raio X por reflexão total, na linha de Luz (D09-XRF) do Laboratório Nacional de Luz Synchrotron. A maior eficiência na redução dos poluentes verificada no processo foto-Fenton foi de 98,1, 96,4, 98,8, 71,8, 32,1 e 98,5 para valores da DQO, cor, turbidez, ST, STF e STV, respectivamente, nas condições operacionais do reator: concentração de ferro de 0,5 gL-1, concentração de peróxido de hidrogênio de 30 gL-1, pH inicial 3 e tempo reacional de 120 min. No entanto a técnica da eletrofloculação não apresentou boa redução nos valores dos parâmetros físico-químicos. Após a aplicação dos processos integrados do foto-Fenton com irradiação solar e da eletrofloculação em tempo de eletrólise de 15 min, foi alcançado valores mínimos de Cr e DQO no efluente tratado, contendo 0,24 mg Cr L-1 e 107 mg O2 L-1 da DQO. O custo do tratamento do efluente e da disposição final do lodo gerado no processo integrado FFs→EF foi de R$ 56,30 m3 do efluente de curtume tratado. Este processo integrado reduziu as concentrações de cromo, ferro e DQO, a níveis permitidos pelas legislações ambientais. Baseada na redução da matéria orgânica e inorgânica, o método integrado FFs→EF pode ser recomendado como uma substituição eficiente ao método individual.
89

Tratamento de efluente têxtil utilizando o processo foto-fenton / Treatment of textile effluent using photo-fenton process

Manenti, Diego Ricieri 25 February 2011 (has links)
Made available in DSpace on 2017-07-10T18:08:15Z (GMT). No. of bitstreams: 1 Diego Ricieri Manenti.pdf: 2926963 bytes, checksum: 74aa89bdde44c5ef6942846129864678 (MD5) Previous issue date: 2011-02-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this work was to study the performance of the photo-Fenton process using both the artificial UV and solar sources on the textile effluent treatments. Preliminary photo-Fenton experiments for mineralization and degradation of organic and inorganic pollutants as well as of synthetic dyes were carried out in order to assess the best experimental conditions by photo-Fenton process. As synthetic textile effluent a mixture of six dyes: Solophenyl orange TGL (C25H33ClN6O6S2), Solophenyl blue 71 (C40H23N7Na4O13S4), Solophenyl scarlet BNLE (C44H32N10Na4O16S4), Solophenyl yellow ARL (C48H26N8Na6O18S6), Solophenyl black FR (C44H32N13Na3O11S3) e Navy Blue 98 (C38H24N5Na3O13S3) that contained 50 mg L-1 concentration was prepared and diluted in distillated water. The photo-Fenton experiments by using a set of high-pressure mercury lamps and solar light as artificial and natural UV irradiation sources were performed in laboratory scale. As reactor operational parameters to be optimized by a 33 full factorial experimental design: hydrogen peroxide and divalent iron ion as well as the initial solution pH were chosen as variables, keeping constant a reaction time of 120 min that was enough to warrant the maximum (chemical oxygen demand) COD and color removal. The efficiency of photo-Fenton process applied in the treatment of synthetic and real effluents, was evaluated based on the parameters: values of COD, color, turbidity, total organic carbon (TOC), absorbance at a wavelength of maximum absorption for the dyes and simple aromatic compounds and conjugated reductions, as well as behavior analysis of the evolution the sulfate, nitrate inorganic, organic nitrogen and ammonia concentrations. Second-degree models for the COD and color removal percents were proposed to model the photo-Fenton experiments data in order to reduce the cost of running such a photo-Fenton experiment as well as to obtain optimum values of the reactor operating parameters. Second-degree models were also validated by ANOVA. Predicted yields showed good validation with experimental yields. The values of the optimized reactor operational parameters were 3.0, 6.0 g L-1, and 0.05 g L-1 for initial pH, hydrogen peroxide and divalent iron concentrations, respectively, for both photo-Fenton processes. Based on this optimized experimental conditions, almost 100% removals of physico-chemical parameter such as COD, color, turbidity and COT for real textile effluents. The aromatics compounds were showed more resistant to reaction, persisting for longer. It can be noticed that the degradtion of the organic and inorganic matters were verified by the nitrification process and, the sulfates formation and reduction. The process presented similar efficiencies with both solar and artificial irradiation, thus suggesting the use of solar photo-Fenton, as it proved to be an efficient alternative besides using a source of clean and renewable energy. / O objetivo deste trabalho é avaliar o desempenho do processo foto-Fenton, utilizando energia solar e artificial como fontes de irradiação UV, no tratamento de efluentes têxteis. Foram realizados experimentos preliminares para avaliar a eficiência do processo foto-Fenton na mineralização e degradação dos poluentes orgânicos e inorgânicos, bem como dos corantes sintéticos. Para tanto, foi preparado o efluente têxtil sintético pela mistura de seis corantes: Laranja TGL (C25H33ClN6O6S2), Azul FGLE (C40H23N7Na4O13S4), Escarlate BNLE (C44H32N10Na4O16S4), Amarelo ARLE (C48H26N8Na6O18S6), Preto FR (C44H32N13Na3O11S3) e Marinho BLE (C38H24N5Na3O13S3), em água destilada, com concentração de 50 mg L-1. Os experimentos foram realizados em reatores de escala laboratorial utilizando fontes de irradiação UV natural e artificial. Os parâmetros operacionais dos reatores: pH inicial e a concentração dos reagentes H2O2 e Fe2+, foram otimizados baseados nos valores da demanda química de oxigênio (DQO) e descoloração, a partir de um planejamento fatorial 33 completo com o tempo de irradiação constante em 120 minutos. A eficiência do processo foto-Fenton, aplicado no tratamento dos efluentes sintético e real, foi avaliada baseada nos parâmetros: redução dos valores da DQO, cor, turbidez, carbono orgânico total (COT), absorvância nos comprimentos de onda de máxima absorção relativos aos corantes e aos compostos aromáticos simples e conjugados, além da análise do comportamento da evolução das concentrações de sulfato, nitrato inorgânico, nitrogênio orgânico e amoniacal. Para auxiliar na obtenção das condições ótimas dos parâmetros operacionais do reator e redução dos custos do processo foto-Fenton, as respostas experimentais para a redução da DQO e da cor foram ajustados por um modelo previsto de segunda ordem, o qual apresentou uma boa modelagem dos dados, validado pela ANOVA. Os valores ótimos operacionais do reator, para ambos os processos foto-Fenton no tratamento do efluente real, foram: pH = 3,0, concentração de H2O2 = 6,0 g L-1 e concentração de Fe2+ = 0,05 g L-1. Nestas condições, foram obtidos valores próximos a 100% de redução dos parâmetros físico-químicos DQO, cor, turbidez e COT. Os compostos aromáticos se mostraram mais resistentes a reação, persistindo por mais tempo. A degradação da matéria orgânica e inorgânica foi verificada analisando a evolução do processo de nitrificação e a formação ou redução de sulfatos. Os processos apresentaram eficiências similares tanto com irradiação solar como artificial, desta forma, sugere-se a utilização do processo foto-Fenton solar, pois mostrou ser uma alternativa eficiente além de utilizar uma fonte de energia limpa e renovável.
90

Emerging Photochemical Processes Involving Iron for Wastewater Treatment

Sciscenko, Iván Matías 22 November 2021 (has links)
Tesis por compendio / [ES] Los procesos (foto-)Fenton fueron empleados para degradar fluoroquinolonas (FQ) (una clase de antibióticos sintéticos considerados CEC) como contaminantes modelo en diferentes condiciones: pH (3 - 8), concentración de contaminante (3 - 300 μM), número de FQ presentes (1, 3 y 5), y matrices de agua (agua ultrapura, salina y de WWTP simulada). Los experimentos se realizaron a escala banco y planta piloto, empleando luz solar (simulada y real) e irradiaciones con luz ultravioleta. Las velocidades de degradación de los contaminantes obtenidas con procesos tipo-Fenton se compararon con las análogas de fotólisis, fotocatálisis heterogénea y H2O2/UV. En igualdad de condiciones, solo a través del proceso foto-Fenton se logró una mineralización significativa de las FQs. En aquellos casos en los que el carbono orgánico total no mostró una disminución considerable, la razón se atribuye a la liberación de subproductos de oxidación. EEM-PARAFAC ha demostrado ser una técnica económica, veloz y que no requiere del uso de reactivos, para seguir simultáneamente la eliminación de la degradación de hasta 5 FQs fluorescentes presentes en una misma muestra, en presencia de interferencias sin calibrar, y obtener información sobre las posibles estructuras moleculares de los intermediarios de reacción. Los resultados indicaron que la fotólisis por sí sola no es capaz de producir cambios importantes en la estructura de las FQs, mientras que con (foto-)Fenton sí que se observó una notable disminución de los scores de los componentes PARAFAC asociados con los compuestos del tipo FQ. Los ensayos de zona de inhibición empleando E. coli mostraron que la actividad antibiótica disminuyó en paralelo con la desintegración de todos los componentes PARAFAC relacionados con las FQs y subproductos similares a estas. El otro aspecto importante de la tesis fue el uso de procesos Fenton basados en ZVI. Algunos CEC, como los compuestos nitroaromáticos, exhiben tasas de degradación lentas incluso cuando son degradadas por una AOP. El desarrollo de trenes de tratamiento ZVI para la degradación de contaminantes ha despertado un gran interés en los últimos años. Este enfoque consiste en un primer pretratamiento solo con ZVI (es decir, reducción, deshalogenación), seguido del proceso Fenton aprovechando los iones de hierro liberados en el primer paso. Con el fin de analizar las posibles ventajas e inconvenientes de esta estrategia en las aplicaciones de tratamiento de aguas residuales, se ha estudiado este enfoque empleando micropartículas de ZVI (mZVI) comerciales utilizando ácido p-nitrobenzoico (PNBA) como contaminante modelo. Se analizó el efecto de la cantidad inicial de mZVI, H2O2, pH, conductividad, aniones y oxígeno disuelto. Utilizando agua natural en condiciones aeróbicas, pH inicial 3,0, y adicionando 1,4 g/L de mZVI, se consiguió en 2 h una reducción del 83% de PNBA 6 μM en ácido p-aminobenzoico (PABA). Se investigó también la conveniencia de separar las mZVI después de la fase reductora (antes de la etapa Fenton) así como la reutilización de las mZVI. El paso de Fenton contra el PABA, más reactivo que PNBA, requirió 50 mg/L de H2O2 para lograr una eliminación de más del 96% en 15 min a pH 7,5 (pH final del pretratamiento reductivo). Las mZVI reutilizadas fueron efectivas por lo menos por un ciclo completo (reducción/oxidación). Este enfoque puede ser interesante para tratar aguas residuales que contienen contaminantes inicialmente resistentes al radical hidroxilo (HO), pero fácilmente reducibles, pudiendo disminuir su carga tóxica y aumentar su reactividad para un paso de oxidación posterior. / [CA] Fenton i foto-Fenton van ser emprats per a degradar fluoroquinolones (FQ) (una classe d'antibiòtics sintètics considerats CEC) com a contaminants model en diferents condicions: pH (3 - 8), concentració de contaminant (3 - 300 μM), nombre de FQ presents (1, 3 i 5), i matriu d'aigua (aigua ultrapura, salada i de WWTP simulada). Els experiments es van realitzar a escala de laboratori i planta pilot, emprant llum solar (simulada i real) i irradiacions amb llum ultraviolada. Les velocitats de degradació de contaminants obtingudes amb processos tipus-Fenton es van comparar amb fotòlisi, fotocatàlisi heterogènia i H2O2/UV. En igualtat de condicions, només a través del procés foto-Fenton es va aconseguir una mineralització significativa de FQ. En aquells casos en els quals el carboni orgànic total no va mostrar una disminució considerable, la raó s'atribueix a l'alliberament de subproductes d'oxidació. EEM-PARAFAC ha demostrat ser una tècnica econòmica, que no requereix de l'ús de reactius, i ràpida, per a seguir simultàniament l'eliminació de la degradació de fins a 5 FQ fluorescents presents en una mateixa mostra, en presència d'interferències sense calibrar, i obtindre informació sobre les possibles estructures moleculars dels intermediaris de reacció. Els resultats van indicar que la fotòlisi per si sola no és capaç de produir canvis importants en l'estructura de les FQ, mentre que amb (foto-)Fenton, sí que es va observar una notable disminució dels scores dels components PARAFAC associats amb el nucli de FQ. Els assajos de zona d'inhibició que empren E. coli van mostrar que l'activitat antibiòtica va disminuir en paral·lel amb la desintegració de tots els components PARAFAC relacionats amb FQ i subproductes similars a FQ. L'altre aspecte important de la tesi va ser l'ús de processos Fenton basats en ZVI. Alguns CEC, com els compostos nitroaromàtics, exhibeixen taxes de degradació lentes fins i tot quan són degradats per un AOP. El desenvolupament de trens de tractament basats en ZVI per a la degradació de contaminants ha despertat un gran interés en els últims anys. Aquesta aproximaciót consisteix en un primer pretractament amb ZVI (és a dir, reducció, deshalogenación), seguit del procés Fenton aprofitant els ions de ferro alliberats en el primer pas. Amb la finalitat d'analitzar els possibles avantatges i inconvenients d'aquesta estratègia en les aplicacions de tractament d'aigües residuals, s'han emprat micropartícules de ZVI (mZVI) comercials. Utilitzant àcid p-nitrobenzoic (PNBA) com a contaminant model, es va analitzar l'efecte de la quantitat inicial de mZVI, H2O2, pH, conductivitat, anions i oxigen dissolt. Utilitzant aigua natural en condicions aeròbiques, pH inicial 3,0, i addicionant 1,4 g/L de mZVI, es va aconseguir en 2 h una reducció del 83% de PNBA 6 μM a àcid p-aminobenzoic (PABA). Es va investigar també la conveniència d'eliminar les mZVI després de la fase reductora (abans de l'etapa Fenton) així com la reutilització de les mZVI. El pas de Fenton front el PABA, més reactiu que PNBA, va requerir 50 mg/L de H2O2 per a aconseguir una eliminació de més del 96% en 15 min a pH 7,5 (pH final del pretractament reductiu). Les mZVI reutilitzades van ser efectives almenys amb un cicle complet (reducció/oxidació). Aquest enfocament pot ser interessant per a tractar aigües residuals que contenen contaminants inicialment resistents al HO, però que es redueixen fàcilment, podent disminuir la seua càrrega tòxica i augmentar la seua reactivitat per a un pas d'oxidació posterior. / [EN] Dark Fenton and photo-Fenton were employed to degrade Fluoroquinolones (FQs) (a class of synthetic antibiotics considered CEC) as model pollutants under different conditions: pH (3 - 8), pollutant concentration (3 - 300 μM), number of present FQs (1, 3 and 5), and water matrix (ultra-pure, salty and simulated wastewater). Experiments were performed at bench and pilot plant scales, employing sunlight (simulated and real) and ultraviolet light irradiations. Obtained pollutant abatement rates with Fenton-related processes were compared with photolysis, heterogeneous photocatalysis and H2O2/UV. At equal conditions, only through photo-Fenton process significant FQs mineralization were achieved. In those cases where total organic carbon had not exhibit a considerable decrease, the reason was attributed to the release of oxidation by-products. Since FQs are fluorescent, we decided to employ fluorescence excitation-emission matrices (EEM) in combination with the chemometric tool, Parallel Factor Analysis (PARAFAC), to track their degradations. Although EEM-PARAFAC related studies are usually focused towards the characterization and monitoring of dissolved organic matter (DOM) in natural waters and wastewater effluents (work also included in this PhD Thesis following the DOM along the different stages of a drinking water plant), it is barely the first time that it is used for the purposes we have here proposed. The objective is demonstrating that EEM-PARAFAC could be a feasible complementary methodology for the study of fluorescent CECs degradations, avoiding the use of expensive and sophisticated techniques (e.g mass spectrometry), not always available. The other important aspect of the PhD Thesis was the use of ZVI-based Fenton processes. Some CECs such as nitroaromatic compounds, exhibit slow degradation rates even with AOPs. The development of new and more efficient ZVI treatment trains for pollutant degradation has been attracting great interest in the last few years. This approach consists of a first pre-treatment only with ZVI (i.e. reduction, dehalogenation), followed by a Fenton oxidation taking advantage of the released iron ions from the first step. In order to analyse the strategy's plausible advantages and potential drawbacks within wastewater treatment applications, reductive/oxidative treatment train based on commercial ZVI microparticles (mZVI) has been studied. The effect of the initial amount of mZVI, H2O2, pH, conductivity, anions, dissolved oxygen were analysed using p-nitrobenzoic acid (PNBA) as model pollutant. 83% reduction of PNBA 6 μM into p-aminobenzoic acid (PABA) was achieved in natural water at initial pH 3.0 and 1.4 g/L of mZVI under aerobic conditions in 2 h. An evaluation of the convenience of removing mZVI after the reductive phase (before the Fenton oxidation one) was investigated together with mZVI reusability. The Fenton step against the more reactive PABA required 50 mg/L of H2O2 to achieve more than 96% removal in 15 min at pH 7.5 (final pH from the pre-reductive step). At least one complete reuse cycle (reduction/oxidation) was obtained with the separated mZVI. This approach might be interesting to treat wastewater containing pollutants initially resistant to hydroxyl radical (HO), but easily reduced, being able to decrease its toxic load as well as increasing its reactivity for a subsequent oxidation step. / Sciscenko, IM. (2021). Emerging Photochemical Processes Involving Iron for Wastewater Treatment [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/177357 / Compendio

Page generated in 0.0727 seconds