Spelling suggestions: "subject:"enerator"" "subject:"benerator""
281 |
Improvement Of The Burnup Of the First Fuel Charge In The CANDU-600 MWe Reactor Through Fuel Bundle ShufflingPresley, James January 1980 (has links)
An analysis was performed in an attempt to increase the fuel burnup of the first fuel charge (first 4560 fuel bundles discharged) of the CANDU-600 MWe reactor by altering the fuelling strategy. The fuelling scheme studied involved re-inserting the two last bundles in a channel
along with six fresh bundles into each refuelled channel. This scheme was compared to the eight bundle shift scheme in which eight fresh bundles are placed into a refuelled channel. The comparison was done using a coarse mesh reactor model with the FMDP computer code. Reactor operation was simulated from 0 to 350 FPD's (Full Power Days). During this period the fuel burnup of the first fuel charge was increased by 11.1%, from 5075 MWD/Te-U to 5637 MWD/Te-U. To accomplish this a 10.8 increase in the average fuelling machine rate was necessary. / Thesis / Master of Engineering (ME)
|
282 |
Dynamic Website and Data Engine Generators for Distributed Enterprise/Business ArchitecturesQaddoura, Fareed 17 December 2004 (has links)
Creating websites providing dynamic services is an extensive process. Intelligent systems are used to create websites with dynamic services. Current intelligent systems are hard to use and configure by the average user. The generated websites are usually custom built to solve one problem and cannot be fully customizable for users on different environments. This thesis presents a technological solution that enables the average user to create websites with dynamic services by providing a number of parameters. The website generator is a web-based application that generates all the components of the website. The components act as portlets and the generated website will be the portal application. The data engine generator creates the website's underlying database. To enable distributed enterprise/business architecture, the data engine generator records the metadata about the database and the website to be generated. The website generator is a cost effective, dynamic, secure, reliable, and scalable solution that outperforms current website generators and portal applications.
|
283 |
Novo MÃtodo e Modelos Para Estudos de Fluxo de PotÃncia e de Curto-circuito / New method and models for power flow and short circuit studies.Adriano Aron Freitas de Moura 18 January 2013 (has links)
nÃo hà / Este trabalho apresenta um novo mÃtodo de fluxo de potÃncia linear o fluxo de potÃncia linear V-teta tambÃm apresenta uma nova modelagem do gerador sÃncrono para estudos de fluxo de potÃncia trifÃsico em redes de distribuiÃÃo desequilibradas radiais e uma modelagem do gerador eÃlico sÃncrono em componentes de fase para estudos de curto-circuito em sistemas de distribuiÃÃo radiais Os resultados revelam que 1) Para o fluxo de potÃncia linear V-teta à possÃvel o cÃlculo de forma desacoplada e linear dos fluxos de potÃncia ativa e reativa no sistema Assim os erros obtidos com o fluxo de potÃncia linear V-teta sÃo em geral menores que os erros obtidos no mÃtodo clÃssico de fluxo de potÃncia CC e espera-se que o mesmo seja usado em muitas aplicaÃÃes onde o mÃtodo clÃssico de fluxo de potÃncia CC à atualmente utilizado 2) Uma nova modelagem à proposta considerando o gerador sÃncrono diretamente conectado a rede elÃtrica Uma outra modelagem jà existente na literatura considerando a conexÃo do gerador atravÃs de retificador e inversor tambÃm à usada As duas modelagens sÃo utilizadas para a realizaÃÃo de estudos de impacto dos sistemas de excitaÃÃo dos geradores sÃncronos em sistemas de distribuiÃÃo com modelagem trifÃsica Os resultados sÃo obtidos utilizando-se o sistema IEEE-13 barras A modelagem do gerador sÃncrono em componentes de
fase sob condiÃÃes desequilibradas permite: a) calcular as injeÃÃes ou consumo de potÃncias ativa/reativa de cada fase na mÃquina, b) simular o gerador sÃncrono como barra do tipo PQ e como barra do tipo PV Juntamente com esses estudos uma anÃlise inÃdita e detalhada de desequilÃbrio de tensÃo inclusive com uma demonstraÃÃo matemÃtica à apresentada 3) A representaÃÃo em componentes de fase do gerador eÃlico sÃncrono nos cÃlculos de faltas de sistemas de distribuiÃÃo
radiais obtÃm resultados mais precisos do que o mÃtodo tradicional das componentes simÃtricas uma vez que valores de impedÃncias mÃtuas de diferentes valores podem ser considerados na anÃlise do sistema / This thesis presents a new method of linear power flow linear power flow V-theta it also presents a new model of synchronous generator for power flow studies in three phase unbalanced radial distribution networks and modeling of wind synchronous generator in phase components for studies of short-circuit in radial distribution systems The results reveal that 1) For the linear power flow V-theta is possible to calculate like a linear and uncoupled form the active and reactive power flows in the system Thus the errors obtained with the linear power flow V-theta are usually
smaller than the errors obtained in classical method of DC power flow and it is expected that the linear power flow V-theta can be used in many applications where the classical method of DC power flow is currently used 2) A new model is proposed, considering the synchronous generator directly connected to the power grid Another existing literature modeling considering the connection from the generator through rectifier and inverter is also used The two modeling are used to perform impact studies of synchronous generators excitation systems for distribution systems with
three-phase modeling The results are obtained using the IEEE 13 bus - test system The modeling of synchronous generator in phase components under unbalanced conditions allow: a) calculate the active / reactive power injections in each phase of the machine b) simulate the synchronous generator as PQ bus-type and as PV bustype Along with these studies an unprecedented and detailed analysis of voltage
unbalance including a mathematical proof is presented 3) the representation of synchronous windmill generators in phase components calculations in short-circuits of radial distribution systems get more accurate results than the traditional method of symmetrical components since values of mutual impedances of different values can be considered in the analysis of the system
|
284 |
A portable uniform random number generator well suited for the rejection methodHörmann, Wolfgang, Derflinger, Gerhard January 1992 (has links) (PDF)
Up to now all known efficient portable implementations of linear congruential random number generators with modulus 2^(31)-1 are working only with multipliers which are small compared with the modulus. We show that for non-uniform distributions, the rejection method may generate random numbers of bad quality if combined with a linear congruential generator with small multiplier. Therefore a method is described that works for any multiplier smaller than 2^(30). It uses the decomposition of multiplier and seed in high order and low order bits to compute the upper and the lower half of the product. The sum of the two halfs gives the product of multiplier and seed modulo 2^(31)-1. Coded in ANSI-C and FORTRAN77 the method results in a portable implementation of the linear congruential generator that is as fast or faster than other portable methods. (author's abstract) / Series: Preprint Series / Department of Applied Statistics and Data Processing
|
285 |
Catalysis and materials development for photolithographyMesch, Ryan Alan 11 September 2015 (has links)
In recent years the microelectronics industry as found itself at an impasse. The tradition pathway towards smaller transistors at lower costs has hit a roadblock with the failure of 157 nm lithography and the continued delays in 13.5 nm extreme ultra violet light sources. While photolithography has been able to keep pace with Moore’s law over the past four decades, alternative patterning technologies are now required to keep up with market demand.
The first section of this dissertation discusses the new resolution enhancement technique develop in the Willson lab termed pitchdivision. Through the incorporation of specifically tailored photobase generators (PBGs) into commercially available resists, the resolution of current 193 tools may be doubled. Special two-stage PBGs were designed and synthesized to increase the image fidelity of pitchdivision patterns.
The next project deals with the design, synthesis, and evaluation of resists that find amplification through unzipping polymers. An aromatizing polyester polymer that acts as dissolution inhibitor in novolac and is inherently sensitive to 13.5 nm exposure is discussed. Initial results show excellent sensitivity and promise towards a new class of EUV resists. / text
|
286 |
Sammanställning av utbildningsmaterial om reservkraft med inriktning dieselaggregat / Compilation of education material regarding back-up power with focus on diesel power generatorsAndersson, Martin, Hägerström, Martin January 2015 (has links)
Dagens samhälle är uppbyggt av ett konstant energiberoende för att få samhällets alla funktioner att fungera. Ett strömavbrott kan därför bli förödande där kontinuerlig tillgång till elektricitet behövs, trots att Sverige har starka elnät har kravet att alltid ha tillgång till elektricitet öppnat upp en marknad för reservkraft. Syftet med det här arbetet var att ta fram kursmaterial för att läsaren ska få en övergripande kunskap om reservkraft med inriktning på dieselkraft. Det framtagna kursmaterialet består av rekommendationer i form av sidhänvisningar ur källor som kan användas vid sammanställning av undervisningsmaterial. Kompendiematerialet kompletteras med en PowerPoint-struktur som kan användas i undervisningssyfte. Genom att studera relevanta källor har vi fördjupat oss i ämnet dieselaggregat och har plockat ut sidhänvisningar enligt kopieringsavtalet, som gäller för högskolan, som vi anser passa bra vid skapandet av ett kompendium. Vi har även strukturerat en grund till en PowerPoint som kan underlätta vid skapandet av föreläsningsmaterial.Denna rapport förklarar ett dieselaggregats tekniska uppbyggnad och vad som är viktigt att tänka på vid dimensionering av ett aggregat. Rapporten tar även upp rekommenderat underhåll samt de miljö- och säkerhetskrav som ställs på att aggregat. / Today's society is composed of a constant energy dependency to get all functions of the modern society to function, a power failure can be devastating. Even though Sweden has a strong power grid, the requirement to always have access to electricity has opened up a market for back-up power. The aim of this work was to create material that could be used in educational purpose and for the reader to get a basic understanding of back-up power with focus on diesel generated power. The course material consists of recommendation of content in the form of page references from sources that fit well in the compilation ofeducation material in the form of a compendium. The compendium is supplemented with a layout of a PowerPoint presentation that can be used for educational purposes. By studying the relevant sources, we have deepened in our topic diesel generated power and have picked out page references, in accordance with the agreement regarding the school copy law, which we consider to be a good fit for the creation of a compendium. We have also created a foundation to a PowerPoint that can facilitate the creation of lecture material. This report explains the structure of a diesel power generator and what is important to consider when sizing a power system. The report also discusses recommended maintenance as well as the requirements placed on a diesel power generator.
|
287 |
Proposta para implantação de microcentrais de geração a gás com utilização de geradores de induçãoNascimento, Carlos Sonier Cardoso do January 2010 (has links)
Este trabalho tem como objetivo investigar a máquina de indução funcionando como gerador. Para isso, são pesquisadas as normas e requisitos para operação interligada à rede de distribuição até o presente momento. Os parâmetros elétricos referente ao circuito equivalente monofásico da máquina de indução de 15 kW, pertencente a um grupo gerador a biogás, são levantados, realizando-se uma caracterização e modelamento destes parâmetros. Os resultados teóricos obtidos têm o intuito de predizer o comportamento das grandezas elétricas quando o grupo gerador operar em condições nominais, interligado a rede de distribuição. Também, estes resultados teóricos são comparados com valores medidos em ensaios de campo utilizando um motor CC de 10 kW como máquina primária. / This study aims at investigate the induction machine operating as a generator. For this, we researched the standards and requirements for the operation connected to the distribution grid to the present date. The electrical parameters concerning the equivalent circuit per phase of a 15 kW induction machine are raised, this machine is part of a small biogas plant. An appropriate characterization and modeling of these parameters are realized and the theoretical results obtained are intended to predict the behavior of electrical units when the generator is placed at nominal operation. Also, these theoretical results are compared with experimental measurements using a 10 kW DC motor as primary mover.
|
288 |
Diretrizes analíticas para projeto de geradores de indução de rotor tipo gaiola de esquiloNascimento, Carlos Sonier Cardoso do January 2014 (has links)
Comumente, as máquinas de indução são projetadas para atuarem como motores. Assim, a presente tese objetiva estudar, analisar e construir um protótipo de máquina de indução concebida para atuar, exclusivamente, como gerador de indução, ou seja, impulsionada acima da velocidade síncrona. As características operacionais ideais em regime permanente são elaboradas intentando diretrizes de projeto. Concomitantemente, o estudo apresenta e investiga modelagens analíticas obtidas por parâmetros concentrados e, também, modelagens numéricas realizadas pelo método dos elementos finitos. Para isto, um gerador de indução trifásico de 2,2 kW tem o rotor do tipo gaiola de esquilo com ranhuras assimétricas projetado e prototipado. O protótipo do gerador de indução visa melhores características de desempenho como o fator de potência e menores perdas, por exemplo, que uma máquina de indução de mesma potência projetada para atuar como motor, mas funcionando como gerador interligado à rede em regime permanente. Os resultados analíticos, numéricos e experimentais em regime permanente do protótipo do gerador de indução e de um motor de indução de mesma potência, mas funcionando como gerador interligado à rede, são apresentados e comparados. Os resultados experimentais obtidos mostram valores nominais de 0,77 e 83,04% de fator de potência e rendimento, respectivamente, para o funcionamento da máquina convencional no ponto de operação próximo ao valor de corrente nominal. Para a máquina de indução projetada como gerador, os valores nominais de 0,82 e 81,35% de fator de potência e rendimento, respectivamente, foram obtidos no ponto de operação próximo ao valor de corrente nominal. / Commonly, induction machines are designed to act as motors. Thus, the present thesis aims to study, analyze and build a prototype of an induction machine designed to work exclusively as induction generator, i.e. driven above synchronous speed. The optimal steady state operating characteristics are elaborated by bringing design guidelines. Concomitantly, this study investigates and presents analytical modeling obtained by lumped parameters and also numerical modeling carried out by the finite element method. Thus, a three-phase squirrel cage induction generator of 2.2 kW with asymmetric rotor slots has designed and prototyped. The prototype of the induction generator aims best performance characteristics such as power factor, for example, than an induction machine of the same power designed to act as a motor, but functioning as generator parallel with the grid. Analytical, numerical and experimental results in steady state operation of the induction generator prototype and of an induction motor of the same power, but functioning as generator parallel with the grid, are presented and compared. The experimental results show nominal values 0.77 and 83.04% of power factor and efficiency, respectively, for the conventional machine in the operating point close to the value of rated current. For the induction machine designed as a generator, the nominal values 0.82 and 81.35% of power factor and efficiency, respectively, were obtained in the operating point close to the value of rated current.
|
289 |
Análise em regime permanente de parques eólicos com máquinas SCIG e DFIGValencia Guerrero, Gabriel Andrés January 2014 (has links)
A geração de energia elétrica com fontes renováveis está em aumento e uma das que tem maior crescimento é a eólica. A instalação das máquinas que aproveitam este recurso pode trazer alguns problemas para a rede elétrica devido à intermitência da velocidade do vento. O presente trabalho tem por objetivo analisar o comportamento de dois tipos de aerogeradores que utilizam gerador de indução e sua interação com o sistema elétrico de potência. Os aerogeradores assíncronos analisados são o de velocidade variável com gerador de indução duplamente alimentado (Doubly-Fed Induction Generator-DFIG) e o de velocidade fixa com gerador de indução de rotor de gaiola de esquilo (Squirrel Cage Induction Generator-SCIG). O caso de estudo está baseado no parque eólico Jepirachi na Colômbia, o qual na atualidade tem aerogeradores de velocidade fixa. Para isto inicialmente foi feita a modelagem do parque eólico considerando alguns parâmetros dos aerogeradores comerciais de velocidade variável e velocidade fixa, junto com os principais componentes da rede elétrica da região para obter uma aproximação da mesma. Posteriormente realizaram-se simulações computacionais para obter o comportamento do sistema elétrico de potência alimentado por estes tipos de aerogeradores. Finalmente, foi realizada uma análise dos efeitos que produzem cada tipo de máquina, no fluxo de potência e no nível de tensão da rede elétrica funcionando em regime permanente, considerando os distúrbios ocasionados pelas mudanças da velocidade do vento. / The generation of electricity from renewable sources is increasing, one of the largest growth is the wind power. However the installation of the machines that leverage this resource could bring some problems to the grid due to the intermittency of the wind speed. This work analyzes the behavior of variable speed wind turbines with Doubly-Fed Induction Generator (DFIG) and fixed-speed wind turbines with Squirrel Cage Induction Generator (SCIG). The case study is based in Jepirachi wind farm in Colombia, that at the present has fixed-speed wind turbines with Squirrel Cage Induction Generator (SCIG). To do this study, initially the modeling of the wind farm considering some parameters of commercial wind turbines with variable speed and fixed speed, also modeling the main components of the electric grid of the region to obtain an approximation of it, after computer simulations we made in order to obtain the behavior of the electric power system powered by these types of turbines. Finally the analysis of the effects produced by each type of machine, in the power flow and the voltage level of the grid operating in steady state, but considering the disturbances caused by changes in wind speed are made.
|
290 |
Modelagem dinâmica e controle de um gerador tipo DFIG em redes de distribuiçãoÁvila, Manuel Ricardo Vargas January 2014 (has links)
Neste momento o Brasil possui uma das mais renováveis matrizes energéticas do mundo, mas o desafio de reduzir os níveis de emissão, permitir o crescimento econômico e atender a aproximadamente um milhão de pessoas sem energia elétrica no pais, requer a pesquisa e o desenvolvimento de novas tecnologias que possibilitem a utilização de fontes limpas e sustentáveis de energia, como é a energia eólica. A energia eólica é considerada, entre as alternativas renováveis existentes, a mais viável no mercado de energia, devido à baixa relação custo/benefício de exploração, tendo apresentado um crescimento exponencial ao longo dos anos. Os principais sistema eólicos classificam-se de acordo com sua operação em dois tipos: sistemas com operação a velocidade fixa e sistemas com operação a velocidade variável. Durante muitos anos a liderança do mercado foi para os geradores que operam a velocidade fixa, sendo a máquina mais usada o gerador de indução de rotor em gaiola (SCIG). A partir do ano 2000, a supremacia no mercado passou a ser para o gerador de velocidade variável. Hoje, tem-se dois tipos de geradores amplamente utilizados em sistemas eólicos que operam a velocidade variável: o gerador síncrono e o gerador de indução com rotor bobinado. Neste trabalho será estudada uma das máquinas que operam a velocidade variável e utilizam geradores de indução com rotor bobinado: o gerador de indução duplamente alimentado (DFIG). Sua importância é principalmente o controle independente da potência ativa e da potência reativa fornecida para a rede elétrica, e à operação com máxima eficiência na conversão de energia. Neste contexto, este trabalho apresenta uma análise comparativa de um sistema de geração utilizando máquinas do tipo DFIG com quatro estratégias de controle: controle da potência ativa e da tensão nos terminais da máquina, controle da potência reativa e da tensão nos terminais da máquina, controle da velocidade de rotação e da tensão nos terminais da máquina, controle da potência ativa e da potência reativa fornecidas pela máquina ao sistema. Esta análise é feita comparando o comportamento do sistema quando sujeito a diversas situações, tais como: variações da demanda de potência da carga elétrica, variações do torque mecânico e ocorrência de uma falta trifásica. O desempenho de sistemas de geração eólica com SCIG também é incluído nesta análise para ilustrar de maneira quantitativa os ganhos obtidos com o uso do DFIG. Os resultados obtidos ilustram as virtudes de cada uma das diferentes possibilidades de modos de operação do DFIG em um sistema de distribuição e permitem uma melhor compreensão da vantagem do desempenho do DFIG em relação à utilização do SCIG. / At present Brazil has one of the most renewable energy matrices in the world, but the challenge of reducing emission levels, allowing the economic growth, and helping about 1 million people without electric energy in the country, requires research and development of new technologies that enable the use of clean and sustainable energy sources, such as wind power. Wind energy is considered among the existing renewable alternatives the more viable in the energy market, due to the low cost / benefit ratio of exploitation, having experienced exponential growth over the years. The wind system are classified according to their operation into two types: operating systems with fixed speed and systems with variable speed operation. For many years the leadership in the market was for fixed speed generator, being the most used machine, the induction generator rotor cage (SCIG). From 2000, the leadership in the market was for variable speed wind turbine. Today, there are two types of wind generators widely used in systems that operate at variable speed: synchronous generator and generator with wound rotor induction. In this work we will study one of the machines that operate at variable speed and use induction generators with wound rotor: the doubly-fed induction generator (DFIG). Its importance is mainly the independent control of active power and reactive power supplied to the grid, and operating at maximum efficiency in energy conversion. In this context, this work presents a comparative analysis of a generation system using DFIG type machines with four control strategies: control of active power and voltage at the terminals of the machine, control of reactive power and voltage at the machine terminals, control the rotational speed and tension in the machine terminals, control of active power and reactive power supplied by the machine. This analysis is done by comparing the behavior of the system when subjected to various situations, such as variations in power demand of electric load, changes in the mechanical torque and the occurrence of a three-phase fault. The performance of wind power generation systems with SCIG is also included in this analysis to illustrate quantitatively the gains obtained using DFIG. The results illustrate the virtues of each of the different possible operating modes of the DFIG in a distribution system and allow a better understanding of the performance advantage of the machine DFIG over the use of the machine SCIG.
|
Page generated in 0.0675 seconds