• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 24
  • 3
  • 1
  • Tagged with
  • 66
  • 66
  • 66
  • 29
  • 29
  • 18
  • 17
  • 16
  • 12
  • 11
  • 11
  • 10
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Odontogênese: construção e validação de um objeto de aprendizagem inovador / Odontogenesis: construction and validation of an innovative learning object

Rosângela Suetugo Chao 05 December 2017 (has links)
Introdução: Há uma demanda social de produção de material educacional interativo, flexível e visualmente atrativo; que tenha fácil acesso, comunicação e veiculação por meio das mídias e da internet, e principalmente que possibilite a difusão do conhecimento. Objetivos: O presente estudo teve como objetivos a construção e validação de objeto de aprendizagem com uso de computação gráfica 3D sobre odontogênese. Método: Baseou-se nos princípios da educação de adultos e na aprendizagem significativa. A construção do objeto de aprendizagem partiu da revisão da literatura e da discussão com grupo de especialistas multiprofissional. A partir destes dados, foi construído um roteiro baseado em uma matriz de objetivos educacionais. Este roteiro direcionou uma produção intelectual em formato de vídeo. Para a validação dessa produção intelectual, foi construído um processo de revisão por pares com análise crítica e sistematizada aplicada a um conjunto de 22 professores e profissionais de expertise reconhecida na área e atuantes em várias universidades distribuídas pelo território brasileiro. Resultados: O objeto de aprendizagem sobre odontogênese incluiu um vídeo elaborado a partir da tecnologia de computação gráfica 3D e narração, com nove minutos de duração. A análise das respostas do grupo de validadores mostrou unanimidade de visão positiva em vários itens do instrumento de validação destacando as afirmativas relacionadas aos movimentos das cenas, entendimento de todas as fases da odontogênese, assim como o uso de imagens tridimensionais e animação auxiliaram o entendimento e aprendizado do tema. Foi considerada uma ferramenta útil para a prática, por trazer uma síntese de informações, condensando conceitos relevantes apresentados de forma dinâmica com propósito educacional. Além disto, foi considerado um objeto de aprendizado flexível por atender a diversos interesses de aprendizado, sendo adaptável a diferentes públicos e objetivos, podendo contribuir com a formação de estudantes, pós-graduandos e profissionais da área de saúde. Conclusão: O processo de validação contribui para o aprimoramento do objeto de aprendizagem considerado adequado, útil, inovador e flexível. De acordo com os validadores, ter contato com essa tecnologia durante suas graduações, teria facilitado o entendimento sobre odontogênese / Introduction: There is a social demand for the production of an interactive educational material, which is flexible and visual attractive; that has an easy access, communication, media and internet placement and primarily that makes the diffusion of knowledge possible. Objective: The aim of this study was the construction and validation of a learning object with the use of 3D computer graphics about odontogenesis. Method: It was based on adults\' education principals and on the significant learning. The construction of the learning object started on the literature review and the discussion with a group of multiprofessional specialists. From these data it was constructed a script based on an educational objectives matrix. This script has directed to an intellectual production in a video format. For the validation of this intellectual production, it was built a pair review process with a critical and systematized analysis applied to a set of 22 professors with expertise in the area and active in several universities distributed in the Brazilian territory. Results: The learning object about odontogenesis resulted a nine minute video elaborated with narration and 3D computer graphics technology. The analysis of the group of validators\' answers showed a positive view unanimity in several items of the validation instrument, highlighting the affirmations related to the movements of the scenes, understanding of all phases of odontogenesis, as well as the use of threedimensional images and animation that assisted the understanding and learning of the theme. It was considered a useful tool for the practice for bringing a synthesis of information, condensing relevant concepts presented dynamically for educational purposes. Furthermore, it was considered a flexible learning object for attending various learning interests, being adaptable to different publics and objectives; it could contribute with potenciality to undergraduate, for the learning of postgraduate students and health professionals. Conclusion: The validation process contributed to the improvement of the learning object that was considered adequate, useful, innovative and flexible. According to the validators, having contact with this technology during their graduation course would have facilitated odontogenesis understanding
42

Desenvolvimento de um sistema para avaliação dos desvios da coluna vertebral em três dimensões- Spine3D / Development of a new three-dimensional system for evaluating spine deformities - Spine3D

Thomaz Nogueira Burke 21 May 2013 (has links)
Introdução: Escoliose é definida como um complexo desalinhamento tridimensional da coluna vertebral na qual há o aparecimento de uma curvatura lateral no plano coronal, normalmente associada com o aplanamento das curvaturas no plano sagital e rotação vertebral em seu eixo longitudinal. O padrão ouro para seu diagnóstico e monitoramento é a medida radiográfica pelo ângulo de Cobb, que possui como principais desvantagens o fato de não avaliar as curvas em três dimensões e expor os pacientes, principalmente os que estão em fase de crescimento, a consideráveis doses de radiação. Objetivo: Esta pesquisa teve como objetivo principal o desenvolvimento de um sistema de avaliação e representação da coluna vertebral em três dimensões, capaz de possibilitar ao usuário a análise quantitativa dos desvios da coluna vertebral nos planos coronal, sagital e transverso. São objetivos secundários estimar a precisão e a exatidão do sistema proposto, e avaliar a sua aplicabilidade a partir de um estudo de caso. Métodos: O Sistema desenvolvido, denominado de Spine 3D, é baseado no uso do controle de videogame Wiimote para rastrear LEDs infravermelhos que compõe um marcador multiplanar em uma cena, e tem como objetivo reconstruir em um ambiente 3D a pose das vértebras torácicas e lombares e, com isto, obter as variáveis angulares e de translação que descrevem seu alinhamento nos planos coronal, sagital e transverso. O experimento para a avaliação da exatidão e precisão consistiu em posicionar o marcador a 50 centímetros de distância do Wiimote, ambos alinhados em um mesmo plano. O marcador foi transladado em intervalos de 10 mm e rotacionado em 5°, 10°, 20° e 30° nos eixos X, Y e Z, com auxílio de um inclinômetro e um paquímetro digital. Os dados foram coletados a 100 Hz. A exatidão foi calculada comparando os resultados encontrados pelo sistema com os valores obtidos pelo inclinômetro e paquímetro digital. A precisão foi calculada a partir do desvio-padrão dos pontos coletados. Resultados: A exatidão média do sistema foi de 0,90° e 0,78mm. A precisão média do sistema foi de 0,62° e 0,42mm. Para o ângulo de Cobb na escoliose, a exatidão e precisão foram de 1,46° e 1,72°, e para a cifose torácica e lordose lombar, a exatidão e precisão foram de 2,82° e 1,60°, respectivamente. Durante o estudo de caso, a diferença entre o Spine3D e a radiografia, para o ângulo de Cobb foi de 1,3° para escoliose curva torácica e 2,24° para escoliose curva lombar. Conclusão: O sistema mostrou ter boa exatidão e precisão após os testes de validação interna. O estudo de caso sugere que a técnica possui potencial para aplicação clínica na avaliação dos desvios da coluna vertebral em três dimensões. / Introduction: Scoliosis is a complex three-dimensional malalignment of the vertebral column in which there is lateral curvature of the spine in the coronal plane, usually associated with flattening of the contour in the sagittal plane and rotation of the vertebrae around their longitudinal axes. Routine clinical analysis of the scoliotic spine is currently based on the radiographic measurement of Cobb angle. Although considered as the golden standard, it has the disadvantage of look over only the two-dimensional aspects of the curve and, over a period of years, the patient will be exposed to a large dose of radiation, especially in early onset curves. There is evidence that this may increase the risk of developing several types of cancer. Objective: This paper describes a new low-cost and radiation-free system to evaluate the three-dimensional aspects of scoliosis, and its concurrent validation in terms of accuracy and precision. Its applicability was tested in a case study. Methods: The system, named Spine3D, has the ability to track an infrared beacon equipped with LEDs (IRLED) to reconstruct the pose of each lumbar and thoracic vertebra in 3D space. The system also calculates the spine alignment to the coronal, sagittal and transverse planes. For accuracy and precision evaluation of the system, the beacon was positioned 50 cm away from the IR camera (Wiimote), aligned with in the same plane. The beacon was increasingly translated at 10 mm intervals and rotated at 5°, 10°, 20° and 30° on all three axes. The capture achieved rate was of 100 Hz roughly and accuracy was calculated comparing the results of Spine3D, digital paquimeter and digital inclinometer. Precision was considered as the standard deviation of the collected data. Results: The average accuracy obtained for the system is 0.90° and 0.78 mm, with precision of 0.62° and 0.42 mm. For Cobb angle calculations in coronal plane, accuracy and precision were of 1.46° and 1.72°, and for thoracic kyphosis and lumbar lordosis, the values were 2.82° and 1.60°. During the case study, the difference between the Cobb angle measured by Spine3D and radiography was 1.3° for thoracic scoliosis curve and 2.24° for lumbar scoliosis curve. Conclusion: The Spine3D system offers a non-invasive and radiation-free alternative for three-dimensional spine assessment and representation. Future studies should indicate if the measures taken by the Spine3D system have correlation with the Cobb angle measured by other methods.
43

Volumetria  e parâmetros biomecânicos detectados pela Ultrassonografia 3D e 2D em aortas abdominais de pacientes com e sem aneurisma / Volumetry and biomechanical parameters detected by 3D and 2D ultrasound in abdominal aortas of patients with and without an aortic aneurysm

Nayara Cioffi Batagini 10 October 2016 (has links)
INTRODUÇÃO: O diâmetro transverso máximo (DTM) de um aneurisma da aorta abdominal (AAA), a medida mais comumente utilizada para determinar quando uma intervenção cirúrgica está indicada nos portadores desta afecção, tem limitações e não reflete o exato risco de rotura. Parâmetros biomecânicos e morfológicos detectados pelo ultrassom (US) com propriedades tridimensionais (3D), podem ajudar a melhor entender o comportamento dos AAA e a determinar o melhor momento para o tratamento cirúrgico deste grupo de pacientes. OBJETIVOS: Verificar a capacidade e a viabilidade do ultrassom bidimensional (US-2D) acoplado com algoritmos de speckletracking em avaliar as propriedades biomecânicas da aorta em pacientes com e sem AAA. Mensurar o volume parcial dos AAA através do ultrassom tridimensional (US- 3D) e compará-lo com o volume estimado pela tomografia computadorizada (TC). MÉTODOS: Este foi um estudo prospectivo. Trinta e um pacientes com aortas normais (grupo 1), 46 pacientes com AAA de diâmetro máximo entre 3,0 - 5,5 cm (grupo 2) e 31 pacientes com diâmetro dos AAA >- 5,5 cm (grupo 3) foram submetidos ao exame de US 2D/3D da aorta infrarrenal, e as imagens foram pós-processadas antes de serem analisadas. No diâmetro máximo, o strain (deformação) circunferencial global e a rotação global máxima acessados pelo algoritmo de speckle-tracking 2D foram comparados entre os três grupos. O strain regional da parede posterior foi também comparado com o da parede anterior em todos os grupos. Os dados de volumetria obtidos usando o US-3D de 40 pacientes foram comparados com os dados de volumetria obtidos por uma TC contemporânea. RESULTADOS: A mediana do strain circunferencial global foi 2,0% (interquartile range (IR): 1,0 - 3,0), 1,0% (IR: 1,0 - 2,0) e 1,0% (IR: 1,0 - 1,75) nos grupos 1, 2 e 3 respectivamente (p < 0,001). A mediana da rotação global máxima diminuiu progressivamente dos grupos 1 ao 3 (1,38º (IR: 0,77 - 2,13), 0,80º (IR: 0,57 - 1,0) e 0,50º (IR: 0,31 - 0,75) (p < 0,001)). Na análise regiãoespecífica, o pico de strain na parede posterior foi significativamente maior que na parede anterior apenas no grupo 3 (p = 0,003). Os volumes dos AAA estimados pelo US-3D tiveram boa correlação com a TC (R-square = 0,76). CONCLUSÕES: O US é capaz de detectar parâmetros biomecânicos distintos entre aortas normais, aneurismas pequenos e aneurismas grandes. A propriedade 3D do US é capaz de determinar o volume dos AAA e apresenta boa correlação com o método padrão ouro (TC). Estudos prospectivos e com seguimento longo são necessários para aprofundar a compreensão não invasiva do comportamento biomecânico e morfológico dos AAA e correlacionar esses parâmetros com o risco de rotura / INTRODUCTION: The maximum transverse diameter of an abdominal aortic aneurysm (AAA), the most common measurement utilized to determine whether surgical intervention is indicated, has limitations and does not reflect the exact risk of rupture. Biomechanical and morphological parameters detected by ultrasound (US), including three-dimensional (3D) properties, can help to better understand the behavior of AAA and to determine the optimal approach to treatment in this group of patients. OBJECTIVES: To demonstrate the feasibility and the ability of the US with speckletracking algorithms to evaluate biomechanical parameters of the aorta in patients with and without abdominal aortic aneurysm (AAA). To measure the partial aneurysm volume by 3D-US and to compare it with the aneurysm volume measured by computed tomography (CT). METHODS: It was a prospective study. Thirty-one patients with normal aortas (group 1), 46 patients with AAA measuring 3.0 - 5.5 cm (group 2) and 31 patients with AAA >- 5.5 cm (group 3) underwent a 2D/3D US examination of the infrarenal aorta, and the images were post-processed prior to being analyzed. In the maximum diameter, the global circumferential strain and the global maximum rotation assessed by 2D speckle-tracking algorithms were compared among the three groups. The regional strain on posterior wall was also compared to that in the anterior wall for all groups. The volumetry data obtained using 3D-US from forty AAA patients was compared with the volumetry data obtained by a contemporary CT. RESULTS: The median global circumferential strain was 2.0% (interquartile range (IR): 1.0 - 3.0), 1.0% (IR: 1.0 - 2.0) and 1.0% (IR: 1.0 - 1.75) in groups 1, 2 and 3, respectively (p < 0.001). The median global maximum rotation decreased progressively from group 1 to 3 (1.38º (IR: 0.77 - 2.13), 0.80º (IR: 0.57 - 1.0) and 0.50º (IR: 0.31 - 0.75) (p < 0.001)). In the region-specific analysis, the strain in the posterior wall was significantly higher than anterior wall only in group 3 (p = 0.003). AAA volume estimations by 3D-US correlated well with CT (R-square = 0.76). CONCLUSIONS: The US can detect distinct biomechanical parameters between normal aorta, small aneurysms and big aneurysms. The 3D property of US is able to determine AAA volume and correlates well with the gold standard technique (CT). Prospective studies and with long-term follow-up are necessary in order to deepen the non invasive understanding of AAA biomechanical and morphological behavior and to correlate those parameters with rupture risk
44

Avaliação por imagem tridimensional das características morfológicas e do crescimento do terço médio da face de pacientes com craniossinostose sindrômica submetidos ao avanço frontofacial em monobloco associado à distração osteogênica / Three-dimensional image evaluation of midface morphological features and growth in syndromic craniosynostosis patients following frontofacial monobloc distraction

Cristiano Tonello 16 December 2016 (has links)
INTRODUÇÃO: A osteotomia em monobloco para o avanço do terço médio e superior da face combinada ao alongamento ósseo gradual consiste em uma modalidade consagrada de tratamento das craniossinostoses sindrômicas. No entanto, alguns aspectos referentes à morfologia do terço médio facial dessas condições, seu comportamento durante o crescimento e quando submetido à cirurgia ainda são pouco compreendidos. OBJETIVOS: Avaliar, por meio de imagens tomográficas tridimensionais, um grupo de pacientes submetidos ao avanço frontofacial em monobloco associado à distração osteogênica, em idade de imaturidade esquelética, quanto às características morfológicas do terço médio da face, aos resultados obtidos com o avanço e seus efeitos no crescimento craniofacial comparados a um grupo não sindrômico. MÉTODOS: A amostra foi constituída de 25 indivíduos, em idade de dentição mista sendo: 16 submetidos ao avanço com exames de tomografia pré e pós-operatório e 9 de um grupo comparativo não sindrômico com exames de tomografia com 1 ano de intervalo durante o período de crescimento. Pontos de referência foram marcados nos modelos de superfície tridimensional do terço médio facial e as seguintes mensurações foram realizadas para o grupo comparativo, dos pacientes antes e após a cirurgia: determinação das dimensões da maxila, ângulos faciais e distâncias entre pontos na base do crânio e superfície da face. A mensuração das distâncias entre pontos correspondentes marcados nas imagens sobrepostas dos diferentes tempos foi utilizada para determinação da magnitude do avanço e comparada aos valores do grupo não sindrômico. Da mesma forma, o crescimento craniofacial prévio à cirurgia foi avaliado em 4 pacientes da amostra que dispunham de exames de tomografia com 1 ano de intervalo previamente ao avanço. O crescimento pós-operatório foi avaliado em 9 pacientes que tinham exames de tomografia com 1 ano de intervalo após o procedimento e ambos foram comparados com o crescimento observado no grupo não sindrômico. RESULTADOS: A maxila dos pacientes com craniossinostose é menor em largura e comprimento comparada aos não sindrômicos. Os ângulos faciais formados pelos pontos orbitário direito e esquerdo e ponto A, zigomático direito e esquerdo e ponto A são estatisticamente diferentes dos não sindrômicos. As distâncias do ponto Sela aos pontos do terço médio são menores nos pacientes comprometidos mas atingem valores comparáveis aos não sindrômicos após o avanço. O crescimento no grupo de crianças com craniossinostose embora não tenha apresentado valores estatisticamente diferentes dos demais, numericamente cresce menos que o grupo comparativo tanto prévia como posteriormente ao procedimento. CONCLUSÕES: O terço médio facial nas craniossinostoses apresenta configuração anatômica alterada, a maxila é hipoplásica e os ângulos faciais mais obtusos denotam uma menor projeção da porção central em relação às laterais. O avanço permite a normalização da posição, no entanto não muda a configuração alterada do terço médio. O crescimento aparentemente está comprometido independente do procedimento cirúrgico / INTRODUCTION: The monobloc osteotomy combined with gradual bone lengthening to advance the upper and midface is an established treatment modality of syndromic craniosynostosis. However, some aspects related to midface morphology and changes during growth and following surgery are still poorly understood. OBJECTIVES: Three-dimensional tomographic image evaluation of patients undergoing frontofacial monobloc distraction group in immature skeletal age is the objective of the study. The morphological characteristics of the midface, the results obtained with the advancement and its effects on craniofacial growth compared to a nonsyndromic group were evaluated. METHODS: The sample consisted of 25 patients of mixed dentition age: 16 submitted to advancement with pre- and postsurgery CT scans and 9 of a comparison nonsyndromic group with CT scans at 1-year intervals during craniofacial growth. Reference points were placed in the 3-dimensional surface models of the midface, and the measurements were performed to compare patients in the pre- and postsurgery groups: determination of the maxillary dimensions, facial angles, and distances between points on the skull base and the surface of the face. The measurement of distances between homologous points placed in the 3D superimposition of images from different times was used to determine the magnitude of the advancement and compared to the values of the nonsyndromic group. Presurgical growth was evaluated in 4 patients that had a 1-year interval prior to the surgery CT scans. Postsurgical growth was evaluated in 9 patients who had CT scans at 1-year intervals after the procedure, and they were compared with the growth of the nonsyndromic group. RESULTS: The maxillary width and length of syndromic patients are smaller compared to the nonsyndromic group. Facial angles formed by right and left orbital points and point A and the right and left zygomatic and Point A are statistically different from those in the nonsyndromic group. The distances from the point Sela to the midface points are lower in syndromic patients but reach values comparable to the nonsyndromic group after advancement. However, growth in the group of children with craniosynostosis did not yield statistically different values of others; it is smaller than the comparison group. CONCLUSION: The midface of syndromic craniosynostosis has a changed anatomical shape, the maxilla is hypoplastic, and the most obtuse facial angles denote a lower projection of the central portion relative to the lateral. The advancement allows the normalization of the position, but the midface shape is not changed.The growth apparently is affected independently of the surgical procedure
45

Optimal integration of shading and binocular disparity for depth perception

Lovell, P.G., Bloj, Marina, Harris, J.M. January 2012 (has links)
We explore the relative utility of shape from shading and binocular disparity for depth perception. Ray-traced images either featured a smooth surface illuminated from above (shading-only) or were defined by small dots (disparity-only). Observers judged which of a pair of smoothly curved convex objects had most depth. The shading cue was around half as reliable as the rich disparity information for depth discrimination. Shading- and disparity-defined cues where combined by placing dots in the stimulus image, superimposed upon the shaded surface, resulting in veridical shading and binocular disparity. Independently varying the depth delivered by each channel allowed creation of conflicting disparity-defined and shading-defined depth. We manipulated the reliability of the disparity information by adding disparity noise. As noise levels in the disparity channel were increased, perceived depths and variances shifted toward those of the now more reliable shading cue. Several different models of cue combination were applied to the data. Perceived depths and variances were well predicted by a classic maximum likelihood estimator (MLE) model of cue integration, for all but one observer. We discuss the extent to which MLE is the most parsimonious model to account for observer performance.
46

Processamento de imagens médicas e parâmetros hemodinâmicos: validação clínica de modelos cardiovasculares assistidos por computação científica / Processing of medical imaging and hemodynamic parameters: clinical

Bezerra, Cristiano Guedes 16 March 2018 (has links)
Introdução: A doença arterial coronária (DAC) é avaliada através dos aspectos anatômicos da placa aterosclerótica ou a partir da repercussão funcional da estenose, por métodos diagnósticos diversos. O ultrassom intravascular (IVUS) fornece uma avaliação anatômica precisa do lúmen e da parede do vaso, tendo sido validado como uma ferramenta útil para guiar a intervenção coronária percutânea (ICP). No entanto, do ponto de vista diagnóstico, o IVUS representa mal o estado funcional (isto é, informação relacionada ao comprometimento de fluxo) do vaso interrogado. A reserva de fluxo fracionada (FFR) é método importante para identificação de isquemia, discriminando as estenoses coronárias que podem se beneficiar de ICP. Objetivamos desenvolver e avaliar o desempenho diagnóstico de um novo algoritmo computacional para estimar a FFR à partir das imagens do IVUS tridimensional (IVUSFR), comparando-o com o método padrão ouro para estimação de fluxo coronário invasivo (FFRPW). Métodos: Pacientes com DAC estável conhecida ou suspeita encaminhados para cateterismo cardíaco eletivo foram submetidos a avaliação complementar com medida de fluxo coronário pelo FFRPW e com imagem intravascular pelo IVUS, no mesmo procedimento, a fim de avaliar lesões intermediárias. As imagens do IVUS foram processadas para gerar uma malha computacional tridimensional que condensa as características geométricas do vaso. O IVUSFR foi obtido utilizando dinâmica de fluido computacional, configurando-se as condições de contorno a partir de características específicas do paciente e do território coronário irrigado. As medidas de FFRPW foram dicotomizadas no limiar de 0,80 para definir lesões hemodinamicamente significativas e avaliar o desempenho diagnóstico do IVUSFR. Resultados: Um total de 34 artérias coronárias de 24 pacientes foi analisado. A área luminal mínima média avaliada pelo IVUS de 4,14 ± 1,74 mm2, e carga de placa média de 66±10% caracterizam o grau intermediário das lesões. O IVUSFR correlacionou significativamente (r = 0,79; p < 0,001) e mostrou boa concordância com a FFRPW, apresentando diferença média de -0,008 ± 0,067 (p = 0,47). O IVUSFR apresentou acurácia, sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de 91%, 89%, 92%, 80% e 96%, respectivamente, para detectar estenoses hemodinamicamente significativas. Conclusão: O processamento computacional do IVUSFR é um novo método que permite a avaliação funcional da estenose coronária intermediária de forma acurada, enriquecendo as informações anatômicas do IVUS / Introduction: Coronary artery disease (CAD) is assessed through the anatomical aspects of the atherosclerotic plaque or through the functional impairment of the stenosis, by different diagnostic methods. Intravascular ultrasound (IVUS) provides accurate anatomic assessment of lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention (PCI). However, from the diagnostic point of view, IVUS poorly represents the functional status (i.e. flow-related information) of the imaged vessel. Fractional flow reserve (FFR) is an important tool to identify ischemia, discriminating coronary stenosis that may benefit from PCI. We aimed to develop and evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional IVUS imaging in estimating fractional flow reserve (IVUSFR), compared to gold-standard invasive measurements (FFRPW). Methods: Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRPW measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Through computational fluid dynamics, IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRPW measurements were dichotomized at the 0.80 thresholds to define hemodynamically significant lesions and evaluate diagnostic performance of IVUSFR. Results: A total of 24 patients with 34 vessels were analyzed. The mean minimum luminal area assessed by IVUS was 4.14 ± 1.74 mm2, and mean plaque burden was 66 ± 10%, characterizing intermediate lesions. IVUSFR significantly correlated (r = 0.79; p < 0.001) and showed good agreement with FFRPW, with a mean difference of -0.008 ± 0.067 (p = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96% respectively to detect significant stenosis. Conclusion: The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of IVUS
47

Processamento de imagens médicas e parâmetros hemodinâmicos: validação clínica de modelos cardiovasculares assistidos por computação científica / Processing of medical imaging and hemodynamic parameters: clinical

Cristiano Guedes Bezerra 16 March 2018 (has links)
Introdução: A doença arterial coronária (DAC) é avaliada através dos aspectos anatômicos da placa aterosclerótica ou a partir da repercussão funcional da estenose, por métodos diagnósticos diversos. O ultrassom intravascular (IVUS) fornece uma avaliação anatômica precisa do lúmen e da parede do vaso, tendo sido validado como uma ferramenta útil para guiar a intervenção coronária percutânea (ICP). No entanto, do ponto de vista diagnóstico, o IVUS representa mal o estado funcional (isto é, informação relacionada ao comprometimento de fluxo) do vaso interrogado. A reserva de fluxo fracionada (FFR) é método importante para identificação de isquemia, discriminando as estenoses coronárias que podem se beneficiar de ICP. Objetivamos desenvolver e avaliar o desempenho diagnóstico de um novo algoritmo computacional para estimar a FFR à partir das imagens do IVUS tridimensional (IVUSFR), comparando-o com o método padrão ouro para estimação de fluxo coronário invasivo (FFRPW). Métodos: Pacientes com DAC estável conhecida ou suspeita encaminhados para cateterismo cardíaco eletivo foram submetidos a avaliação complementar com medida de fluxo coronário pelo FFRPW e com imagem intravascular pelo IVUS, no mesmo procedimento, a fim de avaliar lesões intermediárias. As imagens do IVUS foram processadas para gerar uma malha computacional tridimensional que condensa as características geométricas do vaso. O IVUSFR foi obtido utilizando dinâmica de fluido computacional, configurando-se as condições de contorno a partir de características específicas do paciente e do território coronário irrigado. As medidas de FFRPW foram dicotomizadas no limiar de 0,80 para definir lesões hemodinamicamente significativas e avaliar o desempenho diagnóstico do IVUSFR. Resultados: Um total de 34 artérias coronárias de 24 pacientes foi analisado. A área luminal mínima média avaliada pelo IVUS de 4,14 ± 1,74 mm2, e carga de placa média de 66±10% caracterizam o grau intermediário das lesões. O IVUSFR correlacionou significativamente (r = 0,79; p < 0,001) e mostrou boa concordância com a FFRPW, apresentando diferença média de -0,008 ± 0,067 (p = 0,47). O IVUSFR apresentou acurácia, sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de 91%, 89%, 92%, 80% e 96%, respectivamente, para detectar estenoses hemodinamicamente significativas. Conclusão: O processamento computacional do IVUSFR é um novo método que permite a avaliação funcional da estenose coronária intermediária de forma acurada, enriquecendo as informações anatômicas do IVUS / Introduction: Coronary artery disease (CAD) is assessed through the anatomical aspects of the atherosclerotic plaque or through the functional impairment of the stenosis, by different diagnostic methods. Intravascular ultrasound (IVUS) provides accurate anatomic assessment of lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention (PCI). However, from the diagnostic point of view, IVUS poorly represents the functional status (i.e. flow-related information) of the imaged vessel. Fractional flow reserve (FFR) is an important tool to identify ischemia, discriminating coronary stenosis that may benefit from PCI. We aimed to develop and evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional IVUS imaging in estimating fractional flow reserve (IVUSFR), compared to gold-standard invasive measurements (FFRPW). Methods: Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRPW measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Through computational fluid dynamics, IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRPW measurements were dichotomized at the 0.80 thresholds to define hemodynamically significant lesions and evaluate diagnostic performance of IVUSFR. Results: A total of 24 patients with 34 vessels were analyzed. The mean minimum luminal area assessed by IVUS was 4.14 ± 1.74 mm2, and mean plaque burden was 66 ± 10%, characterizing intermediate lesions. IVUSFR significantly correlated (r = 0.79; p < 0.001) and showed good agreement with FFRPW, with a mean difference of -0.008 ± 0.067 (p = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96% respectively to detect significant stenosis. Conclusion: The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of IVUS
48

Remodeling of three-dimensional organization of the nucleus during terminal keratinocyte differentiation in the epidermis

Gdula, M. R., Poterlowicz, K., Mardaryev, A. N., Sharov, A. A., Peng, Y., Fessing, M. Y., Botchkarev, V. A. January 2013 (has links)
The nucleus of epidermal keratinocytes (KCs) is a complex and highly compartmentalized organelle, whose structure is markedly changed during terminal differentiation and transition of the genome from a transcriptionally active state seen in the basal and spinous epidermal cells to a fully inactive state in the keratinized cells of the cornified layer. Here, using multicolor confocal microscopy, followed by computational image analysis and mathematical modeling, we demonstrate that in normal mouse footpad epidermis, transition of KCs from basal epidermal layer to the granular layer is accompanied by marked differences in nuclear architecture and microenvironment including the following: (i) decrease in the nuclear volume; (ii) decrease in expression of the markers of transcriptionally active chromatin; (iii) internalization and decrease in the number of nucleoli; (iv) increase in the number of pericentromeric heterochromatic clusters; and (v) increase in the frequency of associations between the pericentromeric clusters, chromosomal territory 3, and nucleoli. These data suggest a role for nucleoli and pericentromeric heterochromatin clusters as organizers of nuclear microenvironment required for proper execution of gene expression programs in differentiating KCs, and provide important background information for further analyses of alterations in the topological genome organization seen in pathological skin conditions, including disorders of epidermal differentiation and epidermal tumors.
49

Technical note: Reliability of Suchey-Brooks and Buckberry-Chamberlain methods on 3D visualizations from CT and laser scans

Villa, C., Buckberry, J., Cattaneo, C., Lynnerup, N. January 2013 (has links)
Previous studies have reported that the ageing method of Suchey-Brooks (pubic bone) and some of the features applied by Lovejoy et al. and Buckberry-Chamberlain (auricular surface) can be confidently performed on 3D visualizations from CT-scans. In this study, seven observers applied the Suchey-Brooks and the Buckberry-Chamberlain methods on 3D visualizations based on CT-scans and, for the first time, on 3D visualizations from laser scans. We examined how the bone features can be evaluated on 3D visualizations and whether the different modalities (direct observations of bones, 3D visualization from CT-scan and from laser scans) are alike to different observers. We found the best inter-observer agreement for the bones versus 3D visualizations, with the highest values for the auricular surface. Between the 3D modalities, less variability was obtained for the 3D laser visualizations. Fair inter-observer agreement was obtained in the evaluation of the pubic bone in all modalities. In 3D visualizations of the auricular surfaces, transverse organization and apical changes could be evaluated, although with high inter-observer variability; micro-, macroporosity and surface texture were very difficult to score. In conclusion, these methods were developed for dry bones, where they perform best. The Suchey-Brooks method can be applied on 3D visualizations from CT or laser, but with less accuracy than on dry bone. The Buckberry-Chamberlain method should be modified before application on 3D visualizations. Future investigation should focus on a different approach and different features: 3D laser scans could be analyzed with mathematical approaches and sub-surface features should be explored on CT-scans.
50

Optimizovani protokol magnetno-rezonantne vizuelizacije zgloba kolena na aparatu jačine 3 Tesla / Optimization of magnetic resonance protocol in visualization of the knee joint using 3 Tesla

Njagulj Vesna 28 September 2016 (has links)
<p>Uvod: magnetno rezonantni imidžing (MR) je u &scaron;irokoj uporebi u dijagnostici patolo&scaron;kih poremećaja ekstremiteta. Postoji interes da se redukuje vreme trajanja snimanja tokom pregleda kako bi se povećao komfor pacijenata i redukovali problemi koji su u vezi sa klaustrofobijom i artefaktima koji nastaju pri pomeranju pacijenta tokom dugih snimanja. Trodimenzionalne (3D) izovoksel sekvence pokazale su značajne mogućnosti u redukciji vremena snimanja MR pregledom zgloba kolena bez smanjenja kvaliteta dijagnostičkih mogućnosti. Cilj: uporediti dijagnostičke mogućnosti rutinskog, 2D MR protokola, na 3.0 Tesla MR aparatu, sa 3D True fast imaging, TrueFISP, izovoksel sekvencom u detekciji hondralnih o&scaron;tećenja, ruptura prednjeg ukr&scaron;tenog ligamenta (LCA), ruptura meniskusa i abnormalnosti subhondralne kosti, u korelaciji sa artroskopijom, kao referentnim standardom. Materijal i metode: Studija je odobrena od institucionalnog etičkog odbora. Pacijenti su informisani o studiji i potpisali pristanak za uče&scaron;će u istraživanju. 76 zgloba kolena kod 76 pacijenata (34 ženskog pola; prosečne starosti 36 godina) uključeno je u prospektivnu studiju, snimljeno je standardnim 2D MR protokolom snimanja i 3D TrueFISP sekvencom u sagitalnoj ravni. Svim pacijentima je urađena artroskopija u periodu od maksimum 30 dana nakon snimanja. Dva radiologa, nezavisno jedan od drugog, su evaluirala dobijene snimke. Preciznost u detekciji hondralnih o&scaron;tećenja, ruptura LCA i meniskusa, i abnormalnosti subhondralne kostne srži je određena podudarno&scaron;ću radiolo&scaron;kih i artroskopskih nalaza kao i proverom podudaranja ove dve metode snimanja. Rezultati: prosečna senzitivnost i specifičnost 3DTrueFISP sekvence je bila 75%, 94% respektivno, u dijagnostici o&scaron;tećenja hrskavice, 97%, 97% u detekciji ruptura LCA, 65%, 89% u postavljanju dijagnoze ruptura meniskusa, a dobra podudarnost radiolo&scaron;kih nalaza je dobijena u interpretaciji o&scaron;tećenja subhondralne kosti. Standardnim 2D MR protokolom prosečna senzitivnost i specifičnost je bila 70%, 93%, respektivno, u postavljanju dijagnoze hondralnih o&scaron;tećenja, 94% i 100% u postavljanju dijagnoze rupture LCA, 65%, 88% u detekciji ruptura meniskusa. Zaključak: dijagnostičke mogućnosti upotrebom 3DTrueFISP sekvence su uporedive sa standardnim, 2D, MR protokolom u snimanju zgloba kolena.</p> / <p>Introduction: Magnetic resonance imaging (MR) is widely used to assess internal derangements of the extremities. There is an interest in decreasing examination times to improve patient comfort and reduce the problems related to claustrophobia and motion artifacts, which occur more commonly with long examinations. The three-dimensional (3D) isovoxel true FISP sequence facilitates a noticeable reduction in acquisition time for MR imaging of the knee without reducing diagnostic performance. Objective: To compare the diagnostic performance of conventional, 2D, MR protocol, at 3.0 Tesla MR, with 3D water-excitation true fast imaging with steady-state precession, TrueFISP, an isotropic resolution sequence for detecting articular cartilage defects, anterior crucial ligament tears, meniscal tears and subhondral bone changes of the knee joint, with arthroscopy as reference standard. Materials and methods: The study was institutional review board approved. Written informed consent was obtained from all patients. 76 knees of 76 patients (34 females; mean age 36 years) were prospectively examined by using a conventional 2D MR protocol and sagittal 3D TrueFISP sequence. All patients underwent arthroscopy within a maximum period of 30 days after imaging. Two blinded readers evaluated the MR images. Accuracy for detection of cartilage defects, anterior cruciate ligament and meniscal tears, and subchondral bone abnormalities interobserver agreement, and intermethod agreement were calculated. Results: Overall sensitivity and specificity of 3DTrueFISP sequence were, respectively, 75%, 94% for diagnosis cartilage defects, 97%, 97%, for a diagnosis ACL tears, 65%, 89% for diagnosis of meniscal tears and with good interobserver agreement in interpretation of subhondral bone abnormalities. The standard MR protocol had overall sensitivities and specificities 70%, 93%, respectively, for diagnosis of cartilage defects, 94% and 100% for diagnosis ACL tears and 65%, 88% for diagnosis meniscal tears. Conclusion: The diagnostic perfomance of knee MR imaging performed by using a 3DTrueFISP sequence is comparable to the diagnostic performance of the conventional, 2D, MR protocol.</p>

Page generated in 0.086 seconds