• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 131
  • 66
  • 23
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 251
  • 85
  • 59
  • 51
  • 51
  • 49
  • 48
  • 45
  • 32
  • 32
  • 30
  • 29
  • 26
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Extended life of swimming pools through LCC

Kroll, Stephan January 2012 (has links)
Swimming pools constructed with reinforced concrete require a high level of expertise within both, its planning and execution. To build waterproof concrete shells, extensive concrete technology knowledge, detailed planning of joint formation and high quality safety measures are needed. This thesis evaluates concrete technology features for swimming pool construction in Germany and Sweden. In particular, guidelines by DafStb, DIN and DgfdB provide the planner with detailed advice and specifics about swimming pools. It also gives an overview about the actual condition of swimming pools in Sweden that reached an age of at least 30 years and shows structural consequences of mistakes in planning and construction of swimming pools. The aspect of financial consequences is also analyzed. With the support of the software “Legep”, the methodology of LCC was used to estimate costs in the future. Additionally, a proposal of post tensioned concrete as a more sustainable technology for watertight concrete basins is shown and under equal aspects analyzed and compared.
82

Miljö- och kostnadseffekter av att använda höghållfast stål i taket på Swedbank Arena

Mäkelä, Johan January 2012 (has links)
Examensarbetet är en studie av den fasta delen av takkonstruktionen i Swedbank Arena. Syftet med examensarbetet är att undersöka hur valet av att använda höghållfast stål påverkat kostnader och miljö under hela konstruktionens livstid. I undersökningen har takkonstruktionen dimensionerats med tre olika alternativ där andelen höghållfast stål i konstruktionen har varierats. Nedan beskrivs översiktligt de stålsorter som alternativen är uppbyggda av.   -          Alternativ A innehåller endast konventionellt stål som har sträckgräns 355 MPa. -          Alternativ B är det alternativ som byggts i verkligheten. Den verkliga konstruktionen innehåller stålsorter med sträckgränser mellan 355 MPa - 900 MPa. -          Alternativ C innehåller en större andel höghållfast stål än den verkliga konstruktionen. Detta alternativ innehåller stålsorter med sträckgränser 355- 900 MPa.   Dimensioneringen av takkonstruktionen har utförts med programmet Autodesk Robot Structural Analysis Professional 2010 som innehåller automatisk normkontroll enligt Boverkets handbok om stålkonstruktioner, BSK07. I analysen har två modeller skapats, alternativ A och C, för att kunna jämföras med den verkliga takkonstruktionen, alternativ B. Resultaten från analysen har använts i beräkningarna av kostnad och miljöpåverkan.   För att beräkna miljöpåverkan användes ett livscykelanalysverktyg som är speciellt utvecklat för stål. I studien jämfördes miljöpåverkan för alternativen med höghållfast stål med ett alternativ som endast består av konventionellt stål. Det har antagits att miljöpåverkan under profiltillverkning, montage och användningsfasen är lika stora eller försumbar för studien. Miljöstudien är en jämförelsestudie. Det innebär att områden i konstruktionens livscykel som resulterar i lika stor miljöpåverkan för samtliga alternativ inte tas med i beräkningen.   Kostnadsberäkningen har genomförts i samarbete med Ruukki. Med resultaten från analysen i Robot skapades ett frågeunderlag som Ruukki använde för att beräkna de totala kostnaderna för samtliga alternativ. Det som Ruukki beaktade vid prissättningen var materialpris, svetsning i verkstad, målning, transport och eventuellt byte av kran vid montage. I kostnadsanalysen har det antagits att projekteringskostnader och användning av takkonstruktionen är densamma för samtliga alternativ. Kostnadsanalysen har utförts som en jämförelsestudie mellan de olika alternativen.   Stålmängderna minskar när man använder sig av höghållfast stål. Detta har medfört att både den totala kostnaden och miljöpåverkan för den verkliga konstruktionen blivit lägre i jämförelse med en konstruktion som endast består av konventionellt stål. Genom att använda höghållfast stål har man sparat mycket pengar och samtidigt reducerat miljöpåverkan. / The thesis is a study of the fixed part of the roof structure in Swedbank Arena. The purpose of the study is to investigate how the choice of using high strength steel has influenced costs and environmental impact throughout the entire life cycle. The roof has been designed with three different alternatives in which the proportion of the high-strength has varied. The following text describes briefly which grades the alternatives are composed of.   -          Alternative A contains only conventional steel with a yield strength of 355 MPa. -          Alternative B is the design that has been built. This structure contains steel with a yield strength between 355- 900 MPa. -          Alternative C contains a larger proportion of high-strength steel than the existening construction. This alternative contains steel with a yield strength between 355-900 MPa.   The calculations of the roof structure have been performed with the program Autodesk Robot Structural Analysis Professional 2010 which has an automatic code check according to BSK07, a publication from the Swedish national Board of Housing, Building and Planning. Two different models, alternative A and C, have been created and compared with the real structure, alternative B. The results from this analysis have been used in the calculations of cost and environmental impact.   In the calculations of environmental impact a life cycle analysis tool was used that has been developed especially for steel. The study compared the environmental impact of the alternatives with high strength steel with the alternative that only consists of conventional steel. It has been assumed that the environmental impact in the manufacturing of the profiles, assembly of the steel construction and the use phase is equal or negligible for the study. The environmental study is a comparison study. This means that parts of the constructions life cycle that result in an equal environment impact for all alternatives are not calculated in the study.   The cost estimation was calculated in collaboration with Ruukki. The result of the analysis in Robot was used as a tender request that Ruukki used to calculate the total costs of all alternatives. In the cost calculations Ruukki took into account the differences in material prices, welding in the steel factory, painting, transportation and possible replacement of the crane during assembly. In the cost analysis it has been assumed that the cost of designing the roof structure and the use phase is the same for all alternatives. The cost analysis has been performed as a comparison study between the different alternatives.   The result of the study shows that the steel volume decreased when the structure consists of high strength steel. The decrease of the steel volume resulted in a reduced total cost and environmental impact. By using high strength steel a lot of money has been saved and in the same time the environmental impact has decreased. The thesis is a study of the fixed part of the roof structure in Swedbank Arena. The purpose of the study is to investigate how the choice of using high strength steel has influenced costs and environmental impact throughout the entire life cycle. The roof has been designed with three different alternatives in which the proportion of the high-strength has varied. The following text describes briefly which grades the alternatives are composed of.   -          Alternative A contains only conventional steel with a yield strength of 355 MPa. -          Alternative B is the design that has been built. This structure contains steel with a yield strength between 355- 900 MPa. -          Alternative C contains a larger proportion of high-strength steel than the existening construction. This alternative contains steel with a yield strength between 355-900 MPa.   The calculations of the roof structure have been performed with the program Autodesk Robot Structural Analysis Professional 2010 which has an automatic code check according to BSK07, a publication from the Swedish national Board of Housing, Building and Planning. Two different models, alternative A and C, have been created and compared with the real structure, alternative B. The results from this analysis have been used in the calculations of cost and environmental impact.   In the calculations of environmental impact a life cycle analysis tool was used that has been developed especially for steel. The study compared the environmental impact of the alternatives with high strength steel with the alternative that only consists of conventional steel. It has been assumed that the environmental impact in the manufacturing of the profiles, assembly of the steel construction and the use phase is equal or negligible for the study. The environmental study is a comparison study. This means that parts of the constructions life cycle that result in an equal environment impact for all alternatives are not calculated in the study.   The cost estimation was calculated in collaboration with Ruukki. The result of the analysis in Robot was used as a tender request that Ruukki used to calculate the total costs of all alternatives. In the cost calculations Ruukki took into account the differences in material prices, welding in the steel factory, painting, transportation and possible replacement of the crane during assembly. In the cost analysis it has been assumed that the cost of designing the roof structure and the use phase is the same for all alternatives. The cost analysis has been performed as a comparison study between the different alternatives.   The result of the study shows that the steel volume decreased when the structure consists of high strength steel. The decrease of the steel volume resulted in a reduced total cost and environmental impact. By using high strength steel a lot of money has been saved and in the same time the environmental impact has decreased.
83

Kopplingen mellan Livscykelkostnader och Building Information Modelling / Link between Life Cycle Cost and Building Information Modelling

Blom, Daniel January 2011 (has links)
Detta examensarbete har undersökt vilka möjligheter som skapas genom att använda Building Information Modelling (BIM) för Livscykelkostnadsanalyser (LCCA). Arbetet beskriver först LCCA och sedan hur BIM samt öppna standardiserade dataformat kan användas för LCCA och för kvalitetssäkring av data. Till sist visas hur ett verktyg som räknar ut LCC direkt från en byggnadsmodell kan utformas. Genom att kunna synliggöra konsekvenserna av olika lösningsalternativ och göra kvalitativa LCCA erhålls genomtänkta lösningar och medvetenhet om de framtida förvaltningskostnaderna. För en byggherre som också ansvarar för driften kan dessa alternativsvärderingar och analyser leda till betydligt lägre förvaltningskostnader. För Norska Statsbygg som idag förvaltar 2.6 miljoner kvadratmeter fördelat på 2300 byggnader innebär lägre förvaltningskostnader inte bara besparingar för dem utan även för hela det Norska samhället. Därför är LCCA ett viktigt beslutsunderlag för Statsbygg. För LCCA behövs verktyg som ger adekvata resultat och för detta ändamål är de senaste årens utveckling inom BIM intressant. Syftet med detta arbete var att först beskriva och analysera möjligheten att använda BIM för LCCA och sedan att visa hur ett LCC-verktyg kan utformas. Arbetet grundade sig enbart i kvalitativa arbetsmetoder genom intervjuer och direktmedverkan. I undersökningen har jag valt att intervjua anställda på Statsbygg för att få veta mer om LCC. De har varit drivande i utveckling av metoder och den norska standarden NS3454 sedan 1982, de är också en av Norges största byggherrar som även förvaltar sina byggnader och LCCA får därför stor betydelse. Jag har också valt att fokusera på renhållning som är en av posterna i den norska standarden NS3454 för LCCA. Renhållning valdes eftersom det är den största kostnaden under förvaltningsfasen. Kunskaper om BIM erhölls genom direktmedverkan hos Jotne EPM-Technology i Oslo som har arbetat med öppna standardiserade dataformat och BIM sedan 1985. Som en del av deras utvecklingsmiljö arbetades det fram ett verktyg för beräkning av framtida renhållningskostnader. Slutsatsen i arbetet är att genom användning av BIM för LCCA kan det erhållas bättre kvalitet i den slutliga produkten genom fler möjligheter för optioneering och kvalitetskontroller. Dessutom kan det ge mer adekvata LCCA genom Master Data Management och möjligheten att planera mer i detalj. För att dessa fördelar ska kunna bli verklighet behöver det utvecklas fler verktyg för både förvaltning och LCCA. Det behöver också utvecklas fler kunskapsdatabaser för LCC, underhåll, energi samt rengöring. All utveckling bör dessutom basera sig på öppna standardiserade dataformat. / This thesis has investigated the possibilities of using Building Information Modelling (BIM) for Life Cycle Cost Analys (LCCA). It describes LCC and how BIM can be used for LCC and for data quality control. It also shows how a tool that calculates the LCC directly from a building model can be designed. Being able to highlight the consequences of various design solutions and make qualitative LCCA, results in better solutions and awareness off the future facility management(FM) -costs. For a builder who also is responsible for the operational phase these analysis can lead to significantly lover costs. Statsbygg currently manages 2.6 million square meter spread over 2300 buildings. Lower FM-costs implies savings not only for the company itself, but for the Norwegian society as well. Therefore LCCA is an important decision basis for Statsbygg. LCCA requires tools that provide adequate results, and for this purpose the recent developments in BIM are interesting. BIM enables operational procedures and analysis that previously not was possible and it has potential to be used within the LCCA. The purpose of this work was first to describle and analyze the possibility of using BIM to make LCCA and then to show how a solution for calculating can be designed. The work was based only in qualitative methods through interviews and being a part of developers enviroment. It was chosen to interview employees at Statsbygg to know more about LCC. They have worked with development and methods since 1982 and have extensive expertise in the field. They are one of Norway’s largest property developers, wich also manages its buildings and therefore LCCA is important. It was also chosen to focus on cleaningcosts wich is one of the costs in the Norwegian standard NS 3454 for LCCA. Cleaning was chosen because it is a major cost in the FM-phase. Knowledge of BIM was obtained beeing part of the development enviroment at Jotne EPM-Technology in Oslo who has worked with open standard data formats and BIM since 1985. As part of their enviroment the works with the cleaningcost-tool proceed. The conclusion of this work is that use of BIM for LCCA can obtain better quality of the final product by more opportunities for optioneering and quality controls. Moreover, it may provide more accurate LCCA through master data management systems and the ability to plan in more detail. To realize all benefits it is necessary to develop more tools for FM and LCCA based on open standard data formats. Furthermore, it is necessary to develop knowledge databases for LCC, maintenance, energy and cleaning based on open standard data formats.
84

Framtidsplanerat byggande för koncepthus / Future-planned construction for concept houses

Arlid, Emma, Karlsson, David January 2019 (has links)
Underhåll och fastighetsförvaltningen utgör en väsentlig del av en byggnads livscykel. Vid projekteringsfasen finns sällan en underhållsplan upprättad. Detta medför att fastighetsägarna vid övertagandet från entreprenaden får fastslå en årlig avsättning till underhållsfonden, i den ekonomiska planen, genom att beräkna en viss andel av taxeringsvärdet. Om det vid förstudie och projektering kan kartläggas vilka underhållsåtgärder som har störst påverkan på ekonomi och miljö skulle dessa åtgärder kunna tas hänsyn till redan vid uppförandet. Syftet med arbetet var att identifiera de viktigaste åtgärderna att ta hänsyn till vid underhållsplanering av en flerbostadsfastighet med bostadsrätt som upplåtelseform. Målet för studien var att selektera och rangordna de fem komponenter där materialvalen har störst betydelse ur både ekonomisk och miljömässig synpunkt. Studien har utförts med inriktning på flerbostadsfastigheter producerade som koncepthus. Då teorin gällande underhållsplaner och följderna av materialval under byggandet var mycket begränsad valdes att utföra en intervju. En underhållsplan med tre materialval på var och en av komponenterna har upprättats för att jämföra kostnader över tid. En livscykelkostnadsanalys (LCC) utfördes för att kunna bedöma vilka kostnader som belastar de olika materialalternativen, dock har driftkostnader inte inkluderats. En livscykelanalys (LCA) har genomförts i form av miljödeklarationer (EPD) för varje individuellt material med hjälp av Byggsektorns Miljöberäkningsprogram (BM). Slutsatsen blev att materialvalet av de komponenter som har störst betydelse på fastighetskostnader under en 40-årsperiod är enlig följande: 1. Fasadbeklädnad, 2. Hiss, 3. Fönster, 4. Takbeklädnad, och 5. Parkeringsbeläggning. Om totalkostnaden för dessa komponenter tas med i beräkningen redan vid förstudie och projektering skulle det kunna leda till utgifter för fastighetsägaren över tid.
85

Large-Scale Testing of Lightweight Cellular Concrete Backfill for Sliver-Fill MSE Wall Configurations

Morgan, Meghann Dee 06 April 2023 (has links)
Lightweight cellular concrete (LCC) is an aerated or foamed concrete where 25-80% of the concrete matrix consists of air voids. The high volume of air voids reduces the strength but significantly decreases the weight of the material, which has made it an attractive alternative to soil for retaining structure backfills. Though the use of LCC has increased, little research has been performed on the large-scale behavior of retaining structures containing LCC as backfill. This research test attempts to fill knowledge gaps found with regard to the use of LCC in a mechanically stabilized earth (MSE) wall with a trapezoidal or sliver fill by examining the nature of LCC strength criteria from large-scale failure, failure mechanisms, and failure criteria. A large-scale test box (10 ft. wide x 12 ft. long x 10 ft. high), surrounded by a steel resisting frame, was constructed and filled with a silty sand backfill soil in a 1:1 stair-stepped slope and an LCC sliver fill. The west-facing wall was a two-paneled MSE wall with 16 ribbed steel strip reinforcements running through the LCC backfill. The LCC was poured over three days in equal height lifts to ensure stability. A total of 64 sample cylinder molds and four split mold shear boxes were filled with LCC during placement to help identify LCC material properties, which included density, unconfined compressive strength (UCS), and shear strength. A surcharge test was performed on the large-scale test box six days after initial placement of the LCC due to the unanticipated high strength gain and density found within the placed LCC. Instrumentation collected data on displacement, shear plane, lateral wall pressure, and reinforcement strain throughout testing. Initially, four hydraulic jacks were used during surcharge testing to induce a uniform surcharge load to fail the sliver-fill MSE wall. The strength limit of the steel resisting frame was reached before failure, at which point the number of hydraulic jacks was switched to three for a more critical loading condition. The test was again terminated before complete failure when the steel resisting frame strength limit was met. Though failure was not completed, the sliver-fill MSE wall failure had initiated before testing was terminated at a surcharge load of 70 psi. Results identify the initiation of shear failure within the LCC at about 65 psi, with maximum lateral and axial displacements of about 0.5 in. and 1.2 in., respectively. The shear failure occurs at about 52% of the average UCS of 123 psi. An arcuate shear plane, contrary to the traditional bilinear MSE wall failure surface with inextensible reinforcements, was identified within the LCC backfill, which initiated from the toe of the MSE wall and ended about 8 ft. back from the top of the MSE wall, using lateral displacements from Sondex tube profilometers in the backfill.
86

Fallstudie om integrering av tilluftskanaler i fasadens isolerskikt för FTX-ventilation : -En lönsam byggmetod? / Case study on integrating supply air ducts in the insulation layer of thefacade for MVHR : -A profitable building method?

Lundgren, Jens, Lundgren, Gustav January 2022 (has links)
En onödigt hög energianvändning präglar fastighetsbeståndet i Sverige och möjligheten attgöra en förändring är stor, men sker enligt statistik i små steg. Det finns behov av innovativabyggmetoder för minskad energianvändning, samtidigt som fastighetsägare gynnas av ökadlönsamhet i förvaltningen då driftkostnaderna minskar.Syftet med denna studie är att undersöka lönsamheten med att installera till- ochfrånluftsventilation med värmeåtervinning (FTX) i en befintlig fastighet genom att integreratilluftskanaler i fasaden samtidigt som fastigheten tilläggsisoleras. Förutsättningarna är attfastigheten redan ventileras med fläktstyrd frånluft, samt att teknisk livslängd för fastighetensfasad är slut och i behov av renovering. Studien tar inte höjda hyror i beaktning ochlönsamheten för investeringen skall genereras av de årligt sparade uppvärmningskostnaderna.Metoden för arbetet är en kvantitativ fallstudie som grundar sig i hyresfastighetenSkidstaven i Stockholm som är en av de första fastigheterna i Sverige som har installerattilluftskanaler i fasadens isolerskikt. Källan för all empiri är semistrukturella intervjuer samtkvantitativa enkäter. Den insamlade informationen har använts för att simulera fyra olikascenarier i programmet BIM Energy. Kostnaden för renoveringen samt energianvändningenhar sedans beräknats och analyserats med hjälp av värderingsteorierna; LCC-, payback- ochdirektkapitaliseringsmetoden. Känslighets- samt scenarioanalys utförs för att utreda tänkbarautfall för de olika scenarierna vid olika energipriser.Resultaten visar att energianvändningen för uppvärmning kan reduceras med upp till66%, men dagens fjärrvärmepris och de höga investeringskostnaderna gör att samtligascenarier inte uppnår kraven för lönsamhet i payback- och direktkapitaliseringsmetoden. Isamband med fasadrenovering är integrering av tilluftskanaler i fasadens isolerskikt merekonomiskt lönsamt än traditionell installation av FTX. Då fastigheten står i begrepp atttilläggsisolera fasaden är merkostnaden att installera tilluftskanaler ca 3,4 MSEK, sett ur ettlivscykelperspektiv är kostnaden 2,4 MSEK. / An unnecessarily high energy use characterizes the property portfolio in Sweden and there isan opportunity to make a change, but according to statistics it happens in small steps. There isa need for innovative construction methods for reduced energy use, which at the same timebenefit property owners by increasing profitability as operating costs are reduced.The purpose of this study is to investigate the profitability of installing a mechanicalventilation with heat recovery (MVHR) in an existing property by integrating supply airchannels in the facade at the same time as the property is additionally insulated. Theconditions are that the property is already ventilated with fan-controlled exhaust air, and thetechnical life of the property's facade is over and is in need of renovation. The study does nottake increased rents into account and the profitability of the investment must be generated bythe annually saved heating costs.The method for the work is a quantitative case study based on the rental propertySkidstaven in Stockholm, which is one of the first properties in Sweden to have installedsupply air ducts in the façade of a building. The source of all empirical data issemi-structured interviews and quantitative surveys. The information gathered has been usedto simulate four different scenarios in the BIM Energy program. The cost of the renovationand energy use has later been calculated and analyzed, using the valuation theories; LCCcalculation, the payback method and the direct capitalization method. Sensitivity analysis andscenario analysis is performed to investigate possible future scenarios at different energyprices.The results show that energy use for heating can be reduced by up to 66%, but thecurrent district heating price and the high investment costs mean that not all scenarios meetthe requirements for profitability in the payback and direct capitalization method. Inconnection with facade renovation, integration of supply air ducts in the insulation layer ofthe facade is more economically profitable than traditional installation of FTX. As theproperty is in the process of insulating the facade, the additional cost of installing supply airducts is approximately SEK 3.4 million, seen from a life cycle perspective, the cost is SEK2.4 million.
87

Ackumulatorer som räddar liv : En livscykelkostnadsanalys om UPS som nödkraftkälla

Carlén, Camilla, Sandgathe, Ulrica January 2017 (has links)
Vid strömavbrott på fartyg krävs enligt SOLAS regelverk att en nödkraftkälla startar automatiskt. Världshandelsflottan använder sig idag till största delen av generatorer drivna av en fossildriven förbränningsmotor för detta. Här undersöktes möjligheten att istället använda sig av en UPS. Studien har fokuserat på frågan om det är möjligt enligt gällande regelverk, om det finns produkter på marknaden som uppfyller regelkraven samt hur kostnaderna för de två alternativen skiljer sig vad gäller inköp och underhåll i 25 år. Resultatet för kostnaderna redovisades i en livscykelkostnadskalkyl. Sett till regelverk ifrån Transportstyrelsens författningssamling samt klassificeringssällskapet DNV-GL är det tillåtet att använda ackumulatorer eller generatorer.    För att ha möjlighet att undersöka frågeställningen genom kostnadsförslag, sammanställdes en teoretisk fartygsmodell med svensk flagg. De företag som kontaktades var svenska tillverkare. Resultatet av den LCC som gjordes visade att det idag är billigare att investera i en konventionell nödgenerator. / The SOLAS regulations for merchant vessels states that in the event of loss of power, a backup power supply will start automatically. This paper investigated the possibility to replace the widely-used generator driven by a fossil-fuel powered internal combustion engine, with a UPS. Focus of the investigation included regulations concerning the use of accumulators onboard, market product range fulfilling the legal requirements and price difference based on purchase price and maintenance costs for 25 years. The cost results where compared as a Life Cycle Cost calculation. Regulations by the Swedish transport agency and the Classification DNV-GL allow the use of emergency power from accumulators or generator.   For the possibility to investigate through cost estimations, a theoretical model of a merchant vessel with Swedish flag, was set up. All companies contacted were Swedish manufacturer. The results in the LCC show the situation of today and lets us know that the most cost efficient investment is the conventional emergency generator.
88

En hållbar framtid med solceller för Ljusdalshem : Solcellens betydelse i dagens samhälle samt projektering av en solcellsanläggning för elproduktion på ett flerbostadshus

Nordgren, Sofie January 2017 (has links)
Solceller utvecklas ständigt med avseende på effektivitet och i samband med modulernas minskade inköpskostnad intresserar sig allt fler människor för solenergi. Solen är den renaste energikällan och det finns en stor potential för lönsamma anläggningar i Sverige sett till mängden solinstrålning. Arbetet syftar till att projektera en solcellsanläggning åt Ljusdalshem och beräkna dess lönsamhet. Vidare undersöks solcellens uppbyggnad, vilka solcellstyper som finns på marknaden idag samt vilka faktorer som påverkar en projektering. Undersökningen har genomförts med litteraturstudie av tryckta källor med internet som komplement. En del av informationen har också samlats in från personalen på Ljusdalshem samt från en leverantör med erfarenhet inom området. Energiberäkningarna har utförts genom manuella beräkningar och två olika beräkningsprogram som komplement. Lönsamheten bedöms utifrån nuvärdesmetoden och Payoff-metoden. Fastigheten har två lämpliga takpartier, ett placerat åt sydöst och ett åt sydväst. Takets olika riktningar ger större produktionsspann över dagen men ger lägre totalproduktion. Anläggningen kommer bestå av monokristallina kiselsolceller, växelriktare och effektoptimerare. Tillsammans kan dessa producera el motsvarande 17 procent av fastighetens årsförbrukning. I fastigheten bedrivs verksamheter dagtid, vilket passar bra för att ta emot producerad energi från solceller. Med hänsyn tagit till elprisökning, diskonteringsfaktor, modulerna degradering och nyinvesteringar har nuvärdet påvisat en investering som inte är lönsam. Investeringsstöd till solcellsanläggningar finns att söka hos Länsstyrelsen och är en förutsättning för att anläggningen ska ha en chans att bli lönsam, en lönsam investering kräver även att elprisökningen är större än den antagna. Åtgärder som sänker elförbrukningen ska utföras, beräkningarna baseras därför på en lägre förbrukning än den aktuella. En ännu lägre elförbrukning skulle ge ett annat resultat, vilket är en anledning till att göra nya mer exakta beräkningar när den nya årförbrukningen blir känd. Återbetalningstiden för investeringen är längre än den tekniska livslängden och därmed bidrar inte installationen till företagets lönsamhet med det antagna elpriset och övriga villkor. Då anläggningen ska ses som en referensanläggning och Ljusdalshem har ett miljömål att uppnå finns möjlighet till investering trots de ekonomiska förlusterna. / Solar cells are constantly evolving with regard to efficiency, and in connection with the modules' reduced purchasing costs, more and more people are becoming interested in solar energy. The sun is the purest source of energy, and there is a great potential for profitable plants in Sweden, given the amount of solar radiation. The project is to plan a solar cell facility for Ljusdalshem and calculating its profitability. Furthermore, the structure of the solar cell is investigated, which types of solar cells are present on the market today, and what factors affect the plan. The survey has been conducted with a literature study of printed sources with internet as a complement. Some of the informat-ion has also been collected from the staff at Ljusdalshem and from a supplier with experience in the area. The energy productions were carried out through manual calculations and two different calculation tools as a complement. Profitability is judged based on the present value method and the payoff method. The building has two suitable roof areas, one located to the south-east and one to the southwest. The different directions of the roof provide a larger production span over the day but inhibit overall solar energy production. The plant will consist of monocrystalline silica sols, inverters, and power optimizers. Together they can produce electricity corresponding to 17 percent of the annual consumption. Activities in the building are conducted during daytime, which fits well to receive produced energy from solar cells. Taking into account electricity price increase, discount factor, re-construction, and reinvestment modules, the present value has shown an investment that is not profitable. Investment support for solar power plants is available at the County Administ-rative Board, and is a prerequisite for the profitability of the plant. A profitable investment also requires that the electricity price increase is greater than assumed. Measures that reduce electricity consumption should be performed, therefore, the calculations are based on a lower consumption than the current one. An even lower power consumption would give another result, which is a reason for making more accurate calculations when the new annual consumption becomes known. The repayment period for the investment is longer than the technical life and thus does not contribute to the company's profitability with the assumed electricity price and other terms. Since the plant is to be regarded as a reference facility and Ljusdalshem has an environmental objective to achieve, there is an opportunity for investment despite the economic losses.
89

En jämförelse av koldioxidutsläpp i en byggnads klimatskal beroende på val av isoleringsmaterial / A comparison of carbon dioxide emissions in a building´s external shell related to selection of insulation materials

Rydin, Sara, Olsson, Sofia January 2019 (has links)
Syfte: En betydande del av Sveriges totala växthusgaser kommer ifrån bygg- och fastighetssektorn. Då livscykelperspektivet är ett högaktuellt ämne är det intressant att implementera LCA i bygg- och fastighetsbranschen och genomföra en analys på de isoleringsmaterial som anses vara de traditionella inom branschen. För att resultatet av LCA ska vara applicerbart för företag i branschen är det också av intresse att veta hur LCC skiljer sig mellan de jämförda isoleringsmaterialen. För att resultatet ska vara lätt att identifiera är en sammanställning av kostnad i kontrast till koldioxidutsläpp av intresse. Målet med studien är att bidra med kunskap om olika isoleringsmaterials miljöpåverkan utifrån ett livscykelperspektiv. Likaså att se hur stor skillnad det blir i kostnad mellan isoleringsmaterial med mer eller mindre koldioxidutsläpp, där en förutsättning är att U-värdet är detsamma för de jämförda materialen. Metod: De vetenskapliga metoderna för studien har varit litteraturstudie, fallstudie och dokumentanalys. Som komplement till dessa har beräkningar, livscykelanalyser och livscykelkostnadsanalyser genomförts. Resultat: Lösull av cellulosa minskar koldioxidutsläppet för isoleringen i vindsbjälklag med 94,6 procent till en kostnadsökning motsvarande 30 procent jämfört med stenull. En skiva av cellulosa minskar koldioxidutsläppet för isoleringen i yttervägg med 94,4 procent till en kostnadsökning motsvarande 7 procent jämfört med stenull. En bottenplatta av cellglas minskar koldioxidutsläppen med 65,1 procent till en kostnadsökning motsvarande 55,2 procent jämfört med en bottenplatta av cellplast och betong. Konsekvenser: • Isolering av cellulosa har ett betydligt lägre koldioxidutsläpp än stenull. • Livscykelkostnad för cellulosa är något högre än för stenull. • Utifrån denna studie rekommenderas att prioritera miljö framför kostnad och därför använda cellulosa som isolering i byggnader. • Cellglas är ett miljömässigt hållbart alternativ till cellplast och betong vid grundläggning. • Cellglas har en högre livscykelkostnad än cellplast och betong vid grundläggning. • Utifrån denna studie rekommenderas att prioritera miljö framför kostnad och därför överväga att använda cellglas vid grundläggning av byggnader. Begränsningar: Undersökningen har inte tagit hänsyn till transporter av material. Livscykelanalyserna är gjorda på 1 m2 material med en bestämd tjocklek. Endast två isoleringsalternativ per byggnadsdel har jämförts och hänsyn till materialens fukt-, ljud och brandegenskaper har inte beaktats. Studien är kvantitativ. / Purpose: A big part of the greenhouse gases from Sweden comes from the construction and real estate sector. Since the life cycle perspective is a high currant subject it is interesting to implement LCA to the building industry and perform such an analysis on the insulation materials that are traditionally used in the building industry. To make the result of the LCA applicable for companies in the industry it is also of interest to know how the LCC differs between the compared insulation materials. For the result to be easy to identify it is necessary to make a compilation of the cost in contrast to the carbon dioxide emissions. The goal of this study is to contribute with knowledge about the environmental impact from a life cycle perspective of different insulation materials. As well to see how the cost might change between different insulation materials with more or less carbon dioxide emissions, where a presumption is that the U-value is the same for the compared materials. Method: The scientific methods for the study have been literature study, case study and document analysis. As a complement, calculations, life cycle assessments and life cycle cost analysis have been made. Findings: Loose fill insulation of cellulose reduces the carbon dioxide emissions for insulation in the attic with 94,6 percent to a cost increase of 30 percent compared to stone wool. A board of cellulose reduces the carbon dioxide emissions for insulation in the external wall with 94,4 percent to a cost increase of 7 percent compared to stone wool. A foundation with foamglas reduces the carbon dioxide emissions with 65,1 percent to a cost increase of 55,2 percent compared to a foundation of EPS and concrete. Implications: • Insulation of cellulose have much lower carbon dioxide emissions than stone wool. • Life cycle cost for cellulose are a bit higher than for stone wool. • From this study the recommendation is to prioritize the environment above the cost and therefor use cellulose as insulation in buildings. • Foamglas is a more sustainable alternative to EPS and concrete for foundations. • Foamglas have a higher life cycle cost than EPS and concrete for foundations. • From this study the recommendation is to prioritize the environment above the cost and therefore consider to use foamglas for foundations. Limitations: The study has not included transportations of the materials. The life cycle assessments are made on 1 m2 of material with a fixed thickness. Only two insulation materials in each building part have been analyzed and no regards have been taken to the materials moist, sound, and fire attribute. The study is quantitative.
90

Energieffektivisering av skolbyggnad från 60-talet : Studie av Hållsta skola i Eskilstuna / Energy efficiency improvements of a school building from the 1960s in Hållsta, Eskilstuna

Falck, Agnes January 2010 (has links)
<p>In June 2006 the Swedish government decided that the use of energy in buildings should be reduced by 20 percent until 2020, compared to the level of energy used in 1995. To contribute to this goal, the real estate company “Eskilstuna Kommunfastigheter AB”, set up own goals for their buildings. In 2009, the goal for schools was to have a maximum energy use of 118 kWh/m<sup>2</sup>year for heating and hot water.</p><p>The school “Hållsta skola”, just south of Eskilstuna, exceeds the limit since it used 270 kWh in 2008. The school is heated by oil burners, which is not desirable since oil is a fossil fuel. The aim of this study was to identify cost effective measures for decreased energy use for heating and hot water in the school, and to find alternatives to the oil burners.</p><p>The school was built between 1963 and 1975 and consists of two buildings. The insulation in the roof, walls, windows and floor is poor and the ventilation is mainly performed without heat recovery. Measures including insulation of the roof, new windows, heat recovery in the ventilation system and more effective water taps were studied with Life Cycle Cost analysis (LCC) and Pay-off analysis. The energy use with and without the new performance was calculated with the building simulation program VIP+. If all of the economically favorable measures are carried out the total energy use would decrease to 167 kWh/m<sup>2</sup>year.</p><p>One of the alternatives to oil burners that were suggested is heat pumps. The two types of heat pumps studied, ground source or air source, were both found to be profitable, although the ground source heat pump would be slightly more profitable. In the calculations it was considered that an electric boiler would back up the heat pumps during cold days. With heat pumps, the energy bought for heating and hot water would be about 55 kWh/m<sup>2</sup>year, which is well below the goal of maximum 118 kWh/m<sup>2</sup>year.</p>

Page generated in 0.0324 seconds