• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 132
  • 66
  • 23
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 252
  • 86
  • 60
  • 51
  • 51
  • 49
  • 48
  • 45
  • 32
  • 32
  • 30
  • 29
  • 26
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Energieffektivisering av skolbyggnad från 60-talet : Studie av Hållsta skola i Eskilstuna / Energy efficiency improvements of a school building from the 1960s in Hållsta, Eskilstuna

Falck, Agnes January 2010 (has links)
In June 2006 the Swedish government decided that the use of energy in buildings should be reduced by 20 percent until 2020, compared to the level of energy used in 1995. To contribute to this goal, the real estate company “Eskilstuna Kommunfastigheter AB”, set up own goals for their buildings. In 2009, the goal for schools was to have a maximum energy use of 118 kWh/m2year for heating and hot water. The school “Hållsta skola”, just south of Eskilstuna, exceeds the limit since it used 270 kWh in 2008. The school is heated by oil burners, which is not desirable since oil is a fossil fuel. The aim of this study was to identify cost effective measures for decreased energy use for heating and hot water in the school, and to find alternatives to the oil burners. The school was built between 1963 and 1975 and consists of two buildings. The insulation in the roof, walls, windows and floor is poor and the ventilation is mainly performed without heat recovery. Measures including insulation of the roof, new windows, heat recovery in the ventilation system and more effective water taps were studied with Life Cycle Cost analysis (LCC) and Pay-off analysis. The energy use with and without the new performance was calculated with the building simulation program VIP+. If all of the economically favorable measures are carried out the total energy use would decrease to 167 kWh/m2year. One of the alternatives to oil burners that were suggested is heat pumps. The two types of heat pumps studied, ground source or air source, were both found to be profitable, although the ground source heat pump would be slightly more profitable. In the calculations it was considered that an electric boiler would back up the heat pumps during cold days. With heat pumps, the energy bought for heating and hot water would be about 55 kWh/m2year, which is well below the goal of maximum 118 kWh/m2year.
92

SJÄLVFÖRSÖRJANDE BYGGNADER : En studie om lönsamheten av energiförsörjning med solceller i kombination med vätgasbränsleceller / SELF SUSTAINED BUILDINGS : A study about profitability of energy supply by EV-panels combined with hydrogen fuel cells

Karlsson, Patrik, Eriksson, Kim January 2018 (has links)
Syfte: Dagens samhälle blir mer och mer energimedvetet och regeringen sätter upp riktlinjer för bland annat byggsektorn i form av nya regler från Boverket. Ett av den svenska regeringens mål för klimat- och energipolitiken är att till år 2020 minska klimatutsläppen med 40 % och energianvändningen ska vara 20 % effektivare än i dagsläget. Ett led i detta är att bygga byggnader som är mer energieffektiva eller till och med tillverkar sin egen energi. Byggbranschen i Sverige står i dagsläget för cirka 40 % av koldioxidutsläppen, majoriteten av utsläppen sker vid producering av energi som tillförs byggnaderna under brukningsskedet. Målet för arbetet är att granska lönsamheten hos off-grid-förskolor i en mindre kommun i Mellansverige ur ett ekonomiskt perspektiv. Metod: Arbetet är en fallstudie som undersöker projektering av förskolor som planerar byggas i en mindre kommun i Mellansverige. Förskolan ska vara självförsörjande på energi genom att ha solceller på taket tillsammans med vätgasbränsleceller. Med det systemet ska hela byggnadens energibehov kunna tillgodoses. Intervjuer genomförs med de aktörer som ska bygga förskolan, både från beställarsidan och utförarsidan. Dokumentanalys av bygghandlingar används för att göra en LCC-analys som jämför den planerade energikällan mot bergvärme och passivhus. Resultat: Det är inte ekonomiskt lönsamt att använda vätgasbränslecell med solceller som energikälla. LCC-analysen indikerar att det inte är lönsamt att investera i vätgasbränsleceller som energikälla eftersom initialkostnaden är så hög att den inte går att ta igen ekonomiskt under byggnadens livstid jämfört med de andra två alternativ som undersökts. Formfaktorn är bra men det finns utrymme för förbättringar främst i minskad fönsterarea och en mer kvadratisk byggnad som leder till minskad väggarea och därmed lägre byggpris. Både LCC-analysen och intervjuerna indikerar att vätgasbränsleceller är en dyr teknik i dagsläget. Det behövs fler satsningar från politiskt håll för att få igång debatt om bränsleceller och skapa förutsättningar för att företag och privatpersoner ska kunna satsa på tekniken. Det kan dock vara lönsamt för en kommun på andra sätt, till exempel genom att ny industri och fler jobb lockas till kommunen. Konsekvenser: Slutsatsen är att det i dagsläget inte verkar vara lönsamt med vätgasbränslecell som energikälla. Ämnet behöver studeras i större perspektiv där den nya industrin som genereras av kommunens satsning på vätgasbränsleceller tas i beaktning. Begränsningar: Studien utgår från det planerade projektet i Mariestads kommun och har inte jämförts med några andra liknande projekt. Studien tittar på initial- och driftkostnader och tar inte med miljöaspekten i värderingen om lönsamhet. / Purpose: Today’s society is becoming more and more energy conscious and the government sets guidelines for, inter alia, the construction sector in the form of new regulations by the Boverket. One of the Swedish government´s goals for climate and energy policy is to reduce climate emissions by 40% and 20% more efficient energy use than now. A part of this is to build buildings that are more energy efficient or even produce their own energy. The construction industry is Sweden currently accounts for about 40% of the carbon dioxide emissons, the majority of emissions occur in the production of energy supplied to buildings during the use phase. The aim of the work is to review the profitability of off-grid preschools in a small municipality in central Sweden from an economic perspective. Method: This study is a case study that investigates the planned project of kindergartens in a smaller municipality in mid-Sweden. The kindergarten is supposed to be off-grid, self-sustained, in energy using photo voltaic cells on the roof together with hydrogen fuel cells. With this system the entire energy need of the building will be provided. Interviews are performed with participants of the project, both client and contractor. A document analysis is used to make an LCC analysis that compares the intended energy source with a geothermal one and zero energy building. Findings: It is not economically profitable to use hydrogen fuel cell in conjunction with photo voltaic cells as an energy source. The LCC analysis indicates that it is not profitable to invest in hydrogen fuel cells as an energy source since the initial cost is so high that it can´t be recouped within the life span of the building compared to the two other options investigated. The form factor is good but there is room for improvements especially in cut window area and a square shaped building that leads to smaller wall area and therefore less expensive building. Both the LCC analysis and the interviews indicate that hydrogen fuel cells as of today is an expensive technique. More political engagement is required to start debate about fuel cells and to create conditions for companies and individuals to be able to invest in the technique. It can however be profitable for a municipality in other ways, i.e. new industries and more jobs in the municipality. Implications: The conclusion is that it is not economically profitable to use hydrogen fuel cells as an energy source. The subject needs to be studied in a greater context considering the new industries generated by the municipality’s investment in hydrogen fuel cells. Limitations: The study generates from the planned project in Mariestads municipality and has not compared with other similar projects. The study investigates initial costs and maintenance costs and does not consider the environmental aspect in profitability.
93

Degrada??o foto-fenton de carbono org?nico total em efluentes da ind?stria de beneficiamento de castanha de caju

Souza, K?tia Regina 16 December 2005 (has links)
Made available in DSpace on 2014-12-17T15:01:18Z (GMT). No. of bitstreams: 1 KatiaRS.pdf: 807301 bytes, checksum: 2152eca6964abf006ea9b40c29849d1f (MD5) Previous issue date: 2005-12-16 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / At the cashew nut processing industry it is often the generation of wastewaters containing high content of toxic organic compounds. The presence of these compounds is due mainly to the so called liquid of the cashew nut (CNSL). CNSL, as it is commercially known in Brazil, is the liquid of the cashew nut. It looks like an oil with dark brown color, viscous and presents a high toxicity index due to the chemical composition, i.e. phenol compounds, such as anacardic acid, cardol, 2-methyl cardol and monophenol (cardanol). These compounds are bio resistant to the conventional treatments. Furthermore, the corresponding wastewaters present high content of TOC (total organic carbon). Therefore due to the high degree of toxicity it is very important to study and develop treatments of these wastewaters before discharge to the environmental. This research aims to decompose these compounds using advanced oxidative processes (AOP) based on the photo-Fenton system. The advantage of this system is the fast and non-selective oxidation promoted by the hydroxyl radicals (●OH), that is under determined conditions can totally convert the organic pollutants to CO2 and H2O. In order to evaluate the decomposition of the organic charge system samples of the real wastewater od a processing cashew nut industry were taken. This industry was located at the country of the state of Rio Grande do Norte. The experiments were carried out with a photochemical annular reactor equipped with UV (ultra violet) lamp. Based on preliminary experiments, a Doehlert experimental design was defined to optimize the concentrations of H2O2 and Fe(II) with a total of 13 runs. The experimental conditions were set to pH equal to 3 and temperature of 30?C. The power of the lamps applied was 80W, 125W and 250W. To evaluate the decomposition rate measures of the TOC were accomplished during 4 hours of experiment. According to the results, the organic removal obtained in terms of TOC was 80% minimum and 95% maximum. Furthermore, it was gotten a minimum time of 49 minutes for the removal of 30% of the initial TOC. Based on the obtained experimental results, the photo-Fenton system presents a very satisfactory performance as a complementary treatment of the wastewater studied / Na ind?stria de beneficiamento de castanha de caju ? bastante freq?ente a produ??o de efluentes com altas concentra??es de compostos org?nicos de origem t?xica. A presen?a desses compostos se deve ao LCC contido nas ?guas residu?rias. O LCC ? conhecido comercialmente como l?quido da castanha de caju e tem a apar?ncia de um ?leo de cor marrom escura e viscosa. A toxicidade desse efluente, deve-se ? sua composi??o qu?mica formada por compostos fen?licos, tais como, ?cido anac?rdico, derivados do resorcinol (cardol e 2-metil cardol) e um monofenol (cardanol), entre outros, resistentes aos tratamentos convencionais. Estes efluentes apresentam, invariavelmente, elevados valores de carbono org?nico total (COT). Devido ao grau de toxicidade, ? de grande import?ncia o tratamento desses efluentes antes da sua descarga no meio ambiente. O objetivo desse trabalho foi analisar a ocorr?ncia da degrada??o de COT utilizando o processo oxidativo avan?ado (POA) baseado no sistema foto-Fenton. A vantagem deste sistema ? a oxida??o r?pida e n?o seletiva promovida pelo radical hidroxila (●OH), que sob certas condi??es podem promover a convers?o total dos poluentes org?nicos a CO2 e H2O. Para a avalia??o da degrada??o foi utilizado amostras do efluente aquoso bruto (n?o tratado) de uma ind?stria de beneficiamento de castanha de caju localizada no interior do RN. Os experimentos foram realizados em um reator fotoqu?mico anular de fluxo ascendente, cuja concentra??o de Fe(II) e H2O2 foi baseado em testes preliminares e atrav?s do planejamento experimental Doehlert. As condi??es iniciais dos experimentos foram: ajuste do pH inicial para 3,0, temperatura do sistema foi mantida constante a 30?C e as pot?ncias das l?mpadas usadas foram de 80W, 125W e 250W. Todos os experimentos foram realizados em 4h. Os crit?rios para se avaliar a efici?ncia do sistema foram: a ocorr?ncia da degrada??o atrav?s do valor de COT, colora??o final do efluente ap?s tratamento. De acordo com esses crit?rios foram obtidos os seguintes resultados: a porcentagem de remo??o de COT m?nima 80% e m?xima 95%, tempo m?nimo de irradia??o necess?rio para remo??o 30% do COT inicial foi 49 minutos. Pelos resultados experimentais obtidos, foi conferido um bom desempenho do sistema foto-Fenton como tratamento complementar na remo??o de COT presente nas ?guas residu?rias da ind?stria de beneficiamento de castanha de caju
94

Nyttan av LCC-analyser vid planering av underhållsarbete i SL:s spårtunnlar

Skoglund, Anna January 2012 (has links)
Detta examensarbete syftar till att belysa hur LCC-analyser i dag används vid planeringen av underhållsarbeten i tunnelbanans bergtunnlar. SL är ett aktiebolag som ägs av Stockholms Läns Landsting och ansvarar för den landburna kollektivtrafiken i Stockholms län, vilken inbegriper tunnelbanan. Stockholms tunnelbana invigdes 1950 och har sedan dess byggts ut i etapper. Drygt hälften av sträckningen går i tunnlar. Ett ständigt pågående underhållsarbete av tunnlarna krävs för att säkerställa en god funktion. Ibland är även större underhållsåtgärder nödvändiga, vilka, genom exempelvis avstängning med ersättningstrafik, till större utsträckning påverkar omgivningen. Hur underhållet organiseras och planeras är av stor ekonomisk betydelse och hänger även direkt ihop med anläggningens standard. LCC-analyser resulterar i ett mått på en investerings sammanlagda ekonomiska konsekvenser under dess livstid, inkluderas gör med andra ord bland annat investerings-, drift-, och underhållskostnader. Då detta mått fås för flera alternativ kan en jämförelse av dessa göras och bilda ett beslutsunderlag där det totalekonomiskt mest lönsamma kan väljas, istället för att basera beslutet på enbart den initiala investeringskostnaden. Givetvis måste även andra randvillkor och krav beaktas. Två fallstudier har gjorts för att belysa hur LCC i dagsläget används av SL vid olika typer av underhållsarbeten. I det första fallet har LCC använts för att ta fram beslutsunderlag och i det andra inte alls. Utgångspunkten för examensarbetet har varit att det överlag kan finnas mycket att vinna på att använda LCC inte bara vid nybyggnation utan även vid underhållsarbeten. I dagsläget används LCC-analyser inte konsekvent vid planeringen av underhålls- och reparationsarbeten av SL:s berganläggningar. Inga krav om detta ställs utifrån och SL har inga egna riktlinjer beträffande LCC. Detta kan vara en av orsakerna till att LCC-analyser inte utförs i större utsträckning. Andra kan vara bristande kunskap om metodiken, tidsbrist och delat budgetansvar mellan avdelningar. För att konsekvent införa LCC-analyser vid bergprojektering skulle krav om detta behöva ställas externt eller internt genom en LCC-policy eller reglerande dokument. För att sedan genomföra detta på ett sätt så att alla inblandade förstår nyttan vore information/utbildning av metodiken nödvändigt. Viktigt är att definiera vilka projekt som ska omfattas och när i projektgången LCC ska användas. Förslagsvis kan LCC användas vid behovsanalys och krav om LCC-analyser/LCC-beräkningar kan ställas i förfrågningsunderlag / This thesis aims to highlight how LCC analyses currently are used in the planning of maintenance work in the rock tunnels of the Stockholm Metro. SL is a company owned by Stockholm County Council and is responsible for land-based public transport in Stockholm County, which includes the metro. The Stockholm Metro opened in 1950 and has since been expanded in stages. More than half of the route goes through tunnels. Maintenance of the tunnels is necessary to ensure a good function. Sometimes bigger maintenance actions are required, which at times also affects the surrounding world. How the maintenance is planned and organized is of great economic importance and is also directly connected with the facility's standard. LCC analyses results in a measure of an investment's total economic impact over its lifetime, including investment, operation, and maintenance costs. As this measure is obtained for a number of options, a comparison of these can be made and form a basis for decisions in which the total economically most profitable solution can be selected, instead of basing the decision solely on the initial investment cost. Two case studies have been done to elucidate how LCC is used by SL at different types of maintenance work today. In the first case, an LCC analysis has been used to create a basis for decision making, and in the other case LCC has not been considered at all. The starting point for this thesis has been that there may be much to gain by using LCC analyses not only for new constructions but also in the planning of maintenance work. Today LCC analysis is not consistently used in the planning of maintenance and repair work of SL's rock tunnels. There are no demands on this externally and SL has no own guidelines regarding LCC. This could be one of the reasons that LCC analyses are not practiced in a greater extent. Others may be lack of knowledge of methodology, lack of time and shared financial responsibility between departments. In order to consistently introduce LCC analyses for rock maintenance work it would have to be required externally or internally by an LCC policy or through regulatory documents. The new procedures would have to be implemented in a way so that everyone involved understands the benefits, thus information / education of the methodology would be necessary. It is important to define which projects should be covered by, and in which stages of the projects LCC should be used. As a suggestion LCC analysis could be used to define needs and requirements of LCC-analyses can be set in tender documents.
95

Kalkylering vid funktionsförsäljning : Två fallstudier på tillverkande företag

Jörnklev, Sandra, Mattsson, Nathalie January 2020 (has links)
Bakgrund: Funktionsförsäljning är en affärsmodell som vuxit sig stark på senare år som följd av ett ökat intresse kring cirkulär ekonomi. Trots detta finns det ingen kalkyl utformad för att spegla den nya verklighet som funktionsförsäljning medför. Många företag förstår sig inte på de förändrade processer och kostnader som en övergång från en linjär affärsmodell till funktions-försäljning innebär. Då en kalkyl ligger till grund för beslutsfattande som avser att bidra till lönsamhet, är det ett problem att det inte finns en kalkyl som avspeglar den nya verkligheten vid funktionsförsäljning på ett rättvist sätt.  Syfte: Syftet med denna studie är att undersöka hur och varför kostnader förändras i olika processer i tillverkande företag som övergår från en linjär affärsmodell till funktionsförsäljning. Vidare syftar denna studie till att undersöka hur dessa kostnadsförändringar påverkar vad som bör beaktas vid utformandet av en kalkyl. Metod: Denna studie har genomförts med pragmatismen som vetenskaplig utgångspunkt. Ett iterativt angreppssätt har använts för studien. Vidare har en kvalitativ forskningsdesign använts, där två enkla fallstudier genomförts. Fallföretagen valdes ut genom målstyrt urval samt bekvämlighetsurval. För datainsamling har semistrukturerade intervjuer genomförts. Respondenterna valdes ut genom ett snöbollsurval. Den valda analysmetoden är en cross-caseanalys i kombination med en tematisk analys.  Slutsats: Resultatet av denna studie visar att funktionsförsäljning, trots dess stora initiala investeringar, har potential att leda till kostnadsbesparingar på lång sikt. I syfte att rättvist återspegla det förlänga ansvar som funktionsförsäljning medför, bör tidsperspektivet för kalkylen förlängas. Resultatet visar att flertalet processer påverkas vid en övergång till funktionsförsäljning. Det har framkommit att betydelsen av design har utvidgats i kontexten av funktionsförsäljning, då denna process har stor inverkan på efterföljande processer. Vidare har det framkommit att ett övervakande system innehar en central roll vid funktionsförsäljning då det innebär en större kontroll av kostnaderna, däribland reparation och underhåll samt kostnader för omvänd logistik. Slutligen har det konstaterats att processerna försäljning och relationer blir viktigare. Dessa kostnadsförändringar bör således återspeglas i kalkylen. / Background: Functional sales is a business model that has grown strongly in recent years as a result of increased interest in the circular economy. However, there is no costing model designed to reflect the new reality that functional sales bring. Many companies do not understand how a transition from a linear business model to functional sales affect processes and costs. Since a costing model is the basis for decision-making that aims to contribute to profitability, it is a problem that a costing model which reflects the new reality in functional sales in a fair way does not exist.  Purpose: The purpose of this study is to investigate how and why costs change in different processes in manufacturing companies that transition from a linear business model to functional sales. Furthermore, this study aims to investigate how these cost changes affect what should be taken into consideration when designing a costing model.  Method: This study has been conducted with pragmatism as a scientific starting point. An iterative approach has been used for the study. A qualitative research design has been used, where two simple case studies have been carried out. The case companies were selected through a targeted selection and convenience sampling. For data collection, semi-structured interviews have been conducted. The respondents were selected through a snowball sampling. The selected method of analysis is a cross-case analysis in combination with a thematic analysis. Results: The results of this study show that functional sales, despite their large initial investments, have the potential to lead to cost savings in the long term. In order to fairly reflect the extended responsibilities that function sales entail, the time perspective for the costing model should be extended. The study has shown that several processes are affected by a transition from a linear business model to functional sales. It has emerged that the importance of design has expanded in the context of functional sales, as this process has a major impact on subsequent processes. Furthermore, it has emerged that a monitoring system has a central role in functional sales as it involves greater control of costs, including repair and maintenance and reverse logistics costs. Lastly, it has been found that the processes of sales and relationships become more important. These changes in costs should thereof be reflected in the costing model. / Mistra REES
96

Environmental renovating solutions for Miljonprogrammet to reaching the EU2030 climate and energy framework goals / Miljörenoveringslösningar för miljonprogrammet för att uppnå EU:s 2030 klimat- och energiramverk och mål

Sjöling, Alexander, Marefat, Emil January 2020 (has links)
Climate change is one of the most severe threats that humanity is facing right now; it's ironically a threat that we as humans created ourselves. Residential buildings are the fourth largest source of Green-housegases in the EU and account for 10% of the total Green-house gases. In the summer of 2019, the EUcommittee approved the new EU2030 climate and energy framework to reduce greenhouse gas emissionsand increase renewable energy usage. A big problem for Stockholm are buildings constructed during theMiljonprogrammet, which ranged from 1964-1975 and have not had renovations since their construction.According to our study, companies are working hard to achieve climate and sustainability regulations set by the municipality, which in turn are highly correlated with the EU2030's climate and energy framework. The renovation strategy analysis showed that there is no perfect way or golden strategy torenovate the millionprogram buildings as the projects properties differ and require project-specificstrategies. The recommendation is to find the most optimal amount of insulation for the building, to insulate just to reach the EU 2030 goals is not an optimal solution from an investment standpoint. One significant problem we found when analyzing the renewable energy systems was the law that makes energy transfer between buildings illegal. We found that many companies have problems making aninvestment in solar energy profitable because of the low prices of selling back excess energy to the cities powergrid. According to the interviews, lifting the energy distribution law would make it easier for companies to make solar investment profitable. Furthermore, we found that residential energy storage isnot profitable from a price to efficiency standpoint. A lift of the energy distribution law would open new opportunities for companies to experiment with residential energy storage where more than one buildingis connected to the same storage unit. / Klimatförändringar är ett av de allvarligaste hoten som mänskligheten står inför just nu; Det är ironiskt nog ett hot som vi som människor skapade oss själva. Bostadshus är den fjärde största källan tillväxthusgaser i EU och står för 10% av de totala växthusgaserna. Sommaren 2019 godkände EUkommitténdet nya EU2030-klimat- och energiramverket för att minska utsläppet av växthusgaser och öka användningen av förnybar energi. Ett stort problem för Stockholm är byggnader som byggdes under Miljonprogrammet, som sträckte sig från 1964-1975 som inte har renoverats sedan deras byggande.Enligt vår studie arbetar företag hårt för att uppnå klimat- och hållbarhetsbestämmelser som fastställts av kommunen som i sin tur är högt korrelerade med EU2030:s klimat- och energiramverk. Analysen av renoveringsstrategierna visar att det inte finns något perfekt sätt eller gyllene strategi att renovera Miljonprogram-byggnaderna då projektets egenskaper skiljer sig åt och kräver projektspecifika strategier.Rekommendationen är att hitta den mest ekonomiskt optimala isoleringsmängden, att isolera bara för attnå EU 2030-målen är inte en optimal lösning ur investeringssynpunkt. Ett viktigt problem som vi fann närvi analyserade systemen för förnybara energikällor var lagen som kriminaliserar energiöverföring mellanbyggnader. Vi fann att många företag har problem med att göra investeringar i solenergi lönsam på grund av de låga priserna på att sälja tillbaka överskottsenergi till nätet, enligt intervjuerna skulle upphävandet av energidistributionslagen göra det lättare för företag att göra solcellsinvesteringen lönsam. Dessutom fann vi att energilagring för bostäder inte är lönsamt ur ett pris till effektivitetssynpunkt, en upphävning av energidistributionslagen skulle också öppna nya möjligheter för företag att experimentera med energilagring för bostäder där mer än en byggnad är ansluten till samma lagringsenhet.
97

Verksamhetsanpassad ventilation i kontorshus : En utvärdering av energi- samt kostnadsbesparande åtgärder för ett jämnare inomhusklimat i kontorshuset Vråken i Västerås

Hagström, Markus January 2023 (has links)
We are currently facing a global climate crisis, which demands that we decrease our energy consumption and carbon footprint. An essential area of focus is the energy optimization of buildings. Purpose: The objective of this study was to assess the current indoor climate within the office building Vråken in Västerås and investigate different measures for the ventilation system and identify potential energy and cost savings. Method: A literature review was carried out to establish the theoretical foundation and examine previous research in the subject area. The staff's perception of the indoor climate within the office building was evaluated through a survey. Relevant information was collected to understand the building's construction and current ventilation system. Further on, a model of the office building was established in IDA ICE to simulate the two selected ventilation measures. Finally, a life cycle cost calculation compared the profitability of the studied measures. Results: The results indicate that the measures have a minor impact on the indoor climate compared to the reference case. Assessing the changes in the indoor climate is challenging due to multiple climate parameters and the simulation results of this study are considered uncertain. The results show that the energy consumption of ventilation can be reduced by 46 or 51%. This corresponds to an annual energy savings of either 122 or 110 MWh, depending on the chosen measure. The first measure, which involves installing zone dampers on each floor, has an estimated investment cost of 92 531 SEK. The second measure, which entails equipping one of the floors with a separate air handling unit, is estimated to cost 388 650 SEK. The profitability assessment shows that the reduction in the total life cycle cost is 2 683 332 SEK for the first measure and 2 631 543 SEK for the second measure. In total, both measures result in a cost savings of 45 or 44% over a period of 25 years compared to the buildings current ventilation system. Conclusions: The results from this study are influenced by several factors with varying degrees of impact, including the existing ventilation system, building model and the assessment of the indoor climate. Despite this, the results indicates that the studied measures can maintain an acceptable indoor climate and at the same time save both energy and costs for the ventilation in the office building.
98

En jämförelse mellan användning av prefabricerat element för tilläggsisolering eller ombyggnation av ytterväggar ur ett miljö- och ekonomiskt perspektiv / A comparison between using prefabricated elements for adding insulation or reconstructing the exterior walls from an environmental and economic stand point

Rindberg, Marcus, Zohoorian Izadpanah, Soroush January 2019 (has links)
Purpose: The goal of this study is to conduct an LCA and LCC analysis of an additional insulation panel and a sandwich panel, to see which panel has the most benefits regrading environmental effects and economical effects. The purpose of this study is to conduct a research regarding the economical and environmental effect a refurbishment on the exterior walls of an industrial building, is it more beneficial to add insulation to the existing walls or remodel the exterior walls. The European Union has sat a target to reduce the emission of the greenhouse gases within all sectors including the construction sector. The goal is to reduce the emissions by 80-95 % by the year 2050, calculated by the emission rate from the year 1990. Approximately 20 % of the heating produced within in a building seeps out from the exterior walls, this adds to the importance of optimizing a buildings insulating capabilities. The study can be broken down in to three subcategories. (1) How do you add insulation the exterior walls of an industrial building? (2) Which is more economically benefitable, the reconstruction of existing walls or using prefabricated panels with common goal of adding insulting to an existing industrial building. (3) Which alterative has more impact on the environment, using prefabricate panels or reconstruct the existing walls of a building. Method: Methods used to answer the question above include a literature analysis, a document analysis and a case study with the purposes of conducting a life cycle analysis and life cycle cost analysis.     Findings: The results of the study points towards that insulating on externally was a much better option in our case study, it reduced the chances of having to deal with both thermal bridges and damages caused by structural dampness in the walls. The results from the LCA an LCC analysis showed that the additional insulation panels had a significant advantage. When using the additional insulation panels the overall cost of the project was reduced by 30,3% and Carbon dioxide emissions where deducted by 50,8% in comparison with the sandwich panels, when both alternatives had a combined u-value of 0,16 W/m2K. Implications: The study shows the importance of conducting an LCA and LCC analysis in the start-up process of project, to determine which alternative are more beneficial for the project and the environment. The study also shows that with a relative low investment and environmental impact you can improve the U-value of a building Limitations: The study was focused solely around industrial buildings and the study is limited to the exterior walls. No other building components where taken in consideration. Keywords: Insulation, LCA, LCC, Exterior walls, additional insulation, industrial buildings / Syfte:. Målet med studien var att genomföra en LCA- och LCC-jämförelse avtilläggsisolerings panel och sandwichelement för att utvärdera vilken som var merlönsamt ut ett ekonomiskt- och miljöperspektiv. Syftet med studien var att undersökavilket som var mer lönsamt ur ett ekonomiskt- och miljöperspektiv, att tilläggsisoleraeller en ombyggnation av ytterväggarna på en befintlig industrilokal. EU:s mål är att isamverkan med andra utvecklade länder minska utsläppen av växthusgaserna inomalla sektorer däribland även byggbranschen med 80–95 procent fram till år 2050jämfört med 1990 års nivå. Cirka 20 % av värmen från en byggnad går ut genomytterväggar, därför är det viktig att optimera isoleringsförmågan av ytterväggarna.Detta bryts ner i tre frågeställningar: (1) Hur tilläggsisoleras ytterväggar iindustrilokaler? (2) Vilket är mer lönsamt, ombyggnationer av befintliga väggar elleranvändning av prefabricerade element med tilläggsisolering ur ett ekonomisktperspektiv? (3) Hur påverkas miljön vid användning av prefabricerade element kontraombyggnationer av befintliga byggnader?Metod: För att besvara ovanstående frågeställningar har en litteraturstudie, endokumentanalys, ett flertal beräkningar och en fallstudie med livcykelsanalys (LCA)och livcykelskostnadsanalys (LCC) genomförts.Resultat: Resultatet av denna studie visade att tilläggsisolera utvändigt var ett bättrealternativ för vår industrilokal. Värmen från lokalen värmde upp väggen inifrån ochpå det viset minskades risken för köldbryggor och att fuktskador uppstod. Utifrånbåde LCA- och LCC-analysen som genomförts visade den på att tilläggsisoleringspaneler hade ett övertag. Att använda tilläggsisolerings paneler skulle minskakostnaden med 30,3% och koldioxidutsläppen med 50,8% jämfört med enombyggnation med hjälp av sandwichelement då båda produkterna hade ett beräknatU-värde på 0,16 W/m2K.Konsekvenser: Studien visar hur viktigt det är att utföra en LCA samt LCC analys vidbörjan av ett projekt för att kunna avgöra vilket av alternativen som finns tillgängligasom är mest fördelaktiga för projektet. Studien visar också att med relativt litenmiljöpåverkan samt kostnad kan en befintlig lokals U-värde förbättras.Begränsningar: Denna studie behandlar enbart renoveringen av en industrilokal. Denhar avgränsat till ytterväggarna på lokalen och andra byggnadsdelar ingår inte iberäkningen.Nyckelord: Isolering, LCC, LCA, ytterväggar, tilläggsisolering, industrilokal
99

En energistudie över Fengerfors bruk : Kartläggning och förslag till effektiviseringsåtgärder hos byggnader av industrikaraktär / An energy study of Fengerfors mill : Mapping and proposal of efficiency measures in buildings of industrial nature

Tillman, Johan January 2011 (has links)
I slutet av 1900-talet började man inse konsekvenserna av att förlita sig på icke förnyelsebara energikällor för uppvärmning. Priserna steg i höjden och man valde ofta att byta ut sin oljepanna mot el vilket för tillfället var en lönsam lösning. I och med prisstegringen som skett det senaste decenniet har betydelsen av energieffektivt byggande framstått som allt mer tydlig. Detta innebär att många äldre byggnader ofta kan ha mycket dåliga värmeisolerade egenskaper eftersom både energipriser och byggnormer var lågt ställda vid tiden för uppförning. Uppdragsgivarna till arbetet är en ideell ekonomisk förening vid namn Not Quite med sin bas i Fengerfors bruk, Åmål. De har framfört att de har problem med för höga uppvärmningskostnader och svårigheter med att hålla önskad inneluftstemperatur i deras lokaler. Objekten som beskrivs är av industrikaraktär och har tidigare tillhört ett pappersbruk som lades ned år 1979. Byggnaderna är numera kulturminnesmärkta. Syftet med arbetet har varit att åt uppdragsgivarna utföra en kartläggning där energianvändning och potentiella effektiviseringsåtgärder relaterat till de aktuella objekten analyseras. Detta för att uppnå tillfredsställande uppvärmning samtidigt som energiförbrukningen om möjligt kan reduceras. Kostnadseffektiviteten för de specifikt föreslagna åtgärdsalternativen skall också analyseras. Målet med arbetet har varit att med hjälp av simulering utföra kartläggningen där energianvändning, dimensionerande värmeeffektbehov samt potentiella effektiviseringsåtgärder analyseras. Åtgärderna bestod i huvudsak av tilläggsisolering, tätning, intermittent drift, värmeåtervinning samt byte av fönster. Kostnadseffektiviteten analyserades genom en livscykelkostnadskalkyl utifrån värmekällorna ved, pellets och luft-/luftvärmepump. Slutsatsen är att föreslagna åtgärdsalternativ reducerar energiförbrukningen i avsevärd omfattning samtidigt som en tillfredsställande inneluftstemperatur erhålls. Objekten har efter att effektiviseringsåtgärderna tillämpats uppnått en energiförbrukning likvärdig med dagens normalbyggnader i Sverige. Livscykelkostnadskalkylen visar att nuvärdet för respektive åtgärdsalternativ i samtliga relevanta ekonomiska framtidsscenarier leder till stora besparingar. Arbetet har också visat att betydelsen av tillfredsställande diskretisering är oerhört signifikativ i denna typ av simulering. / In the late 1900s society began to realize the consequences of relying on non-renewable energy sources for heating. Prices were increasing heavily and because of that people often chose to replace their oil boiler with electricity which at the time was a viable option. With the rise in prices that has occurred over the past decade the importance of energy efficient measures seemed increasingly clear. With that said many older buildings often have poor thermal properties since both energy prices and construction standards were considerably lower back then. The client Not Quite is a nonprofit association based in Fengerfors mill, Åmål. They have expressed dissatisfaction over increasing heating costs combined with problems getting the desired thermal comfort related to their premises. The objects described are of industrial nature and has previously been used to a paper mill which closed in 1979. The buildings are now classified as part of a cultural monument. The intention of this dissertation has been to map the energy use and to evaluate appropriate efficiency measures related to the specific objects. This includes getting the demanded thermal comfort in combination with possibly reducing the energy consumption. The cost-effectiveness of proposed efficiency measures will also be evaluated. The objective of this dissertation has been to through the use of simulation identify the energy consumption, required thermal input and potential energy efficiency measures. The efficiency measures consisted mainly of adding insulation, air sealing, intermittent heating, heat recovery and window replacements. Cost-effectiveness was evaluated through a life cycle cost analysis with the different heat sources of wood, pellets and air source heat pumps. The conclusion has been that the proposed efficiency options related to each object reduces energy consumption to a considerable extent, while an adequate heating is achieved. The objects have through these measures obtained just as good energy consumption rates as standard considered buildings in Sweden. The life cycle cost analysis shows us that the present value of the proposed efficiency measures in all economic case scenarios results in great cost savings. It has also been shown that a satisfactory discretization of building elements is very important in this type of simulation.
100

Energieffektivisering av luftbehandlingsaggregat : En kartläggning och energieffektivisering av luftbehandlingsaggregat

Mooshtak, Mohsen, Ekström, Fredrik January 2015 (has links)
Denna rapport kommer att undersöka elanvändningen på ventilationsaggregaten i R-huset på Mälardalens högskola och även undersöka om byte av fläkt och motor i ventilationsaggregat vid eventuellt hög elanvändning är ekonomisk lönsamt. R-husets byggår är 1993 och har de mest uråldriga ventilationsaggregaten av skolans fastigheter. Ett ventilationsaggregats livslängd kan uppskattas mellan 20-30 år. Enligt undersökningar finns det stora möjligheter till energieffektiviseringsåtgärder i sektorn bostäder och service där ventilationsaggregat med föråldrad teknik och komponenter kan vara miljöbovar med hög elanvändning. En avgränsning i arbetet är att ventilationsaggregatet med högst specifik fläkt effekt (SFP) ska undersökas noggrant i form av energieffektivisering. Energieffektiviseringen kommer att begränsas till luftbehandlingsaggregatets fläktar och motorer. Kartläggning genomfördes med tryckmätningar på ventilationsaggregaten i R-huset och även el mätningar. El mätningarna behövdes för att beräkna den aktuella elanvändningen för fläktarna. Resultatet av den beräknade elanvändningen för vardera fläkt visade sig vara hög. Tryck mätningarna utfördes för att få fram tryckuppsättningen för fläktarna i aggregaten och vid beräkning av till- och frånluftsflöde. Tryckuppsättningen och flöde över fläktar behövdes vid val av ny fläkt och motor. Resultatet av kartläggningen visar att det totala SFP-värdet som står för den specifika fläkteffekten är höga i jämförelse vid nyproduktion där boverkets byggregler har krav på SFP-värde under 2,0 kW/(m3,s). Högsta SFP-värdet ligger på 4,4 kW/(m3/s) och en livscykelkostnad (LCC) utfördes för detta ventilationsaggregat. LCC-kalkylen baseras på en kalkylperiod på 10 år då på befintliga fläktar och motorer bedöms ha den livslängden. Kalkylräntan är satt till 9 %, energiprisökningen 5 % och detta ger en real kalkylränta på 4 %. Elpriset är valt till det aktuella på 0,80 kr/kWh. LCC-kalkylen visar att det inte är lönsamt att byta till nya fläktar och motorer. Payback metoden gav 12 års återbetalningstid vilket är länge i jämförelse med studerad litteraturstudie. En känslighetsanalys utfördes med ett fördubblat elpris och då blev det ekonomiskt lönsamt att byta befintliga fläktar och motorer till nya. / This report will examine the electricity consumption of the ventilation units in the R building at Mälardalen University and also investigate whether replacing the fan and motor in the ventilation unit with new combined fan and engine units in the event of high electricity consumption is economic profitable. The building was built in 1993 and has the oldest ventilation units of all properties at the university. A ventilation unit’s life can be estimated to last for 20-30 years. According to studies, there are major opportunities for energy efficiency measures in the residential and service sector, where ventilation systems with outdated technology and components can be energy wasters with high electricity consumption. A limitation of this work is that the ventilation unit with the highest Specific Fan Power (SFP) should be examined carefully in terms of energy efficiency. Energy efficiency will be limited to the air handling fans and motors. Mapping was conducted with pressure measurements in the ventilation units and also electrical measurements were done. Electricity measurements are needed to calculate the current electricity consumption of the fans. The result of the estimated power consumption of each fan was found to be high. Pressure measurements were performed to obtain the pressure of the fans in the units and to calculate supply and exhaust air flow. The pressure rise and flow of the fans are needed in order to select a new fan and motor. The result of the survey shows that the total SFP value is high in comparison with the new construction where Boverkets regulations requirements for SFP value is below 2.0. The highest SFP-value is 4.4 kW / (m3 / s) and a Life Cycle Cost (LCC) calculation was performed for that ventilation unit. The LCC calculation is based on a calculation time period of 10 years, where the existing fans and motors are predicted to last for 10 years. The discount rate is set at 9%, energy with a price increase of 5% and this gives a total discount rate of 4%. Electricity prices are up to date and are 0.80 SEK / kWh. LCC calculation shows that it is not profitable to switch to new fans and motors and as payback method gave a 12-year repayment period. A sensitivity analysis was performed with a redoubled electricity price and it then became economically viable to replace existing fans and motors with new ones.

Page generated in 0.0252 seconds