• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • Tagged with
  • 51
  • 51
  • 11
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Microlasers de cavidades estádio aplicados à detecção nanovolumétrica / Stadium cavities microlasers applied to the nanovolumetric detection

Silva Filho, Adenir da 15 August 2018 (has links)
Orientador: Newton Cesário Frateschi / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-15T03:39:57Z (GMT). No. of bitstreams: 1 SilvaFilho_Adenirda_D.pdf: 7071967 bytes, checksum: 323c5d4f6939473d571146b5d6531fda (MD5) Previous issue date: 2010 / Resumo: Este trabalho apresenta o uso de cavidades ressonantes baseadas em geometrias de bilhares caóticos construídas em meios semicondutores opticamente ativos, visando seu aproveitamento ao sensoriamento. Apesar do comportamento clássico caótico do estádio, a descrição quântica, no limite semiclássico, mostra inesperados acúmulos de densidade de probabilidade sobre muitas trajetórias periódicas fechadas, chamadas cicatrizes. A literatura mostra que o espaço físico das trajetórias relacionadas a cada cicatriz pode ser obtido pela soma da densidade de probabilidade de auto-estados na vizinhança de cada cicatriz. Classicamente, as trajetórias ligadas a cada auto-estado possuem órbitas muito próximas devido a sua instabilidade, e quando misturadas, definem uma órbita de largura não nula. No domínio óptico, isomórfico ao problema quântico descrito acima, as trajetórias vêm de um tratamento de traçado de raios e os auto-estados são os modos eletromagnéticos estacionários. Particularmente, no caso da cavidade dielétrica, o sistema é aberto, uma vez que a luz pode ser transmitida para fora do ressonador. Desta forma, há grande mistura dos modos e uma seleção maior daqueles que podem sobreviver por terem trajetórias com ângulos internos de incidência maiores que o ângulo crítico para reflexão total interna. Em uma trajetória fechada e curta, modos estacionários são definidos e essas trajetórias têm maior probabilidade de serem observadas, em relação a outras possíveis. Quando o ressonador é constituído por um meio ativo opticamente, este confinamento realiza a realimentação óptica do sistema, cujo ganho óptico permite o estabelecimento estável e coerente de tais trajetórias. Estes resultados inspiraram a realização deste trabalho, cuja grande motivação foi investigar o processo de seleção modal e aplicá-lo em dispositivos práticos para sensoriamento em pequenos volumes. Experimentalmente foi desenvolvida uma técnica híbrida de fabricação utilizando um sistema de íons focalizados (FIB) juntamente com técnicas de microfabricação convencionais para a produção de cavidades estádio com meio ativo de poços quânticos de InGaAsP. Finalmente, foram obtidos resultados da emissão espectral com grande concordância com a previsão teórica baseada numa abordagem matemática simples de soma incoerente de cicatrizes. A seleção modal foi demonstrada com a alteração da excentricidade e com a inserção de furos sobre as trajetórias. A aplicação ao sensoriamento foi explorada tanto pela observação do espectro de emissão quanto pela detecção de fotocorrente por estádios emissor e detector integrados. Variações de até 80% de fotocorrente e alterações significativas do espectro foram observadas para detecção de isopropanol e água. Estes resultados mostram possibilidades de sensoriamento prático utilizando os estádios / Abstract: This work presents the development of resonant cavities based on chaotic billiard geometries built with semiconductor active optical medium for sensing applications. In spite of the classically chaotic behavior of the stadium, the quantum description of the problem in the semi-classical limit shows unexpected accumulations of the density of probability on closed periodic paths called scars. The literature shows that the physical space of the paths related to a given scar can be obtained by adding several eigen-states neighboring each scar. Classically, the paths connected to each eigen-state have very close orbits due to their instability which, when mixed, define a non-zero width orbit. In the optical domain, isomorphic to the quantum problem described above, the paths are a result of the ray treatment and the eigen-modes are the stationary electromagnetic modes. Particularly, in the case of a dielectric cavity, the system is open for light can escape the resonator. Therefore, there is a great mixture of modes and a strong selection of modes with paths with incidence angle below the critical angle. In a closed and short path, stationary modes are defined and those paths have larger probability of observation. When the resonator has an optically active medium, the confinement provides optical feedback to the system which with optical gain allows the establishment of coherent and stable scars. These results inspired this work where the process of modal selection was investigated and applied for sensing in small volumes. Experimentally, a hybrid fabrication approach based on Focused Ion Beam (FIB) and conventional micro-fabrication techniques was used to produce stadium optical cavities with InGaAsP quantum well active region. Finally, we obtained the spectral emission of the devices with good agreement with our simulation based on a simple mathematical approach employing the incoherent summation of the scars. The modal selection with the modification of the eccentricity of the cavity and with the insertion of holes along the scars was demonstrated. The application to sensing was explored by the observation of the emission spectrum as well as by measured photo-current on detection between stadia emitter and detector integrated. Photo-current variations of up to 80% and significant changes of the emission spectrum were observed for isopropanol and water detection. These results show possibilities of practical sensing by stadiums / Doutorado / Física / Doutor em Ciências
42

Efeitos da ativação do EDTA por laser diodo ou com ultrassom na limpeza e obturação dos canais radiculares. /

Pradelli, Jéssica Arielli. January 2020 (has links)
Orientador: Fábio Luiz Camargo Villela Berbert / Resumo: O objetivo desse estudo foi avaliar um protocolo de aplicação de dois diferentes Lasers de Diodo ativando a solução de EDTA, comparando-o com a ativação convencional ou ultrassom, avaliando a penetrabilidade do EDTA e a penetrabilidade e adesividade do cimento endodôntico obturado. Esse estudo ex vivo, utilizou 50 dentes unirradiculados e padronizados, distribuídos aleatoriamente em 5 grupos (n=10) para iniciarmos a fase de irrigação final: Grupo Controle (CN) – inundação com EDTA 17% sem agitação. Manual Convencional (MV) - Inundação com EDTA 17% e agitação com lima K#45; Ultrassom (UL) – inundação com EDTA 17% energizado com ultrassom (PUI); TheraLase (TL) – inundação com EDTA 17% energizado com Laser Diodo Thera Lase Surgery e grupo Gemini (GM) – inundação com EDTA 17% energizado com Laser Diodo Gemini. Na solução de EDTA 17% foi adicionado o marcador Verde de Malaquita para futura avaliação em microscopia confocal. As raízes foram obturadas, pela técnica de cone único e cimento obturador AH Plus com adição de Rodamina B. As raízes foram seccionadas em 3 discos por terço, e um disco de cada terço foi selecionado para análise em microscopia confocal a laser e teste de Push-Out. Quando a penetrabilidade do EDTA e do cimento obturador, houve diferença estatística dos grupos UL, TL e GM quando comparados com os grupos CN e MV, porém quando comparado os grupos TL e GM com o grupo UL, não houve diferença estatística. E quanto a resistência de união, não houve diferença estatísti... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
43

Perfil de resistência a antibióticos e a terapia fotodinâmica antimicrobiana exibida por isolados ambientais, orais e extra-orais de Serratia marcescens / Analysis of resistance profile of action of antibiotics and antimicrobial photodynamic therapy isolated in environmental, and extra-oral oral Serratia marcescens

Parente, Ticiana Mont'Alverne Lopes January 2010 (has links)
PARENTE, T. M. L. Perfil de resistência a antibióticos e a terapia fotodinâmica antimicrobiana exibida por isolados ambientais, orais e extra-orais de Serratia marcescens. 2010. 90 f. Dissertação (Mestrado em Biotecnologia) - Curso de Medicina - Campus de Sobral, Universidade Federal do Ceará, Sobral, 2010. / Submitted by Djeanne Costa (djeannecosta@gmail.com) on 2016-04-18T15:28:12Z No. of bitstreams: 1 2010_dis_tmlparente.pdf: 50723625 bytes, checksum: 536c8be1802258847a68d8c4bdad58aa (MD5) / Approved for entry into archive by Djeanne Costa (djeannecosta@gmail.com) on 2016-04-18T15:39:33Z (GMT) No. of bitstreams: 1 2010_dis_tmlparente.pdf: 50723625 bytes, checksum: 536c8be1802258847a68d8c4bdad58aa (MD5) / Made available in DSpace on 2016-04-18T15:39:33Z (GMT). No. of bitstreams: 1 2010_dis_tmlparente.pdf: 50723625 bytes, checksum: 536c8be1802258847a68d8c4bdad58aa (MD5) Previous issue date: 2010 / Serratia marcescens is widely distributed in nature, but has emerged in the last years as important nosocomial pathogen with resistance of many antimicrobial drugs. This study aimed to verify the susceptibility of Serratia marcescens isolates from environment, from oral infections and from extra-oral infections to different antibiotics and evaluate the antimicrobial effect of photodynamic antimicrobial therapy as biotechnology tools reducing bacterial growth in planktonic cells and biofilm. E-test® were performed for fifty-five strains and the PACT for the thirty strains more resistant to antimicrobials tested. The antimicrobial effect of toluidine blue O, associated with 4,72 J cm-2 of a light-emitting diode , was evaluated. Before and after the treatments, bacterial inocula were analysed with regard to the number of colony- forming units. For antimicrobials, we observed that the 55 strains analyzed, 13 (23.63%) were resistant to doxycycline, but only one (1.81%) isolate showed resistance to ciprofloxacin, another to tobramycin and another to cefotaxime, 24 ( 43.63%) strains had intermediate sensitivity to doxycycline, all were sensitive to imipenem and most were sensitive to ciprofloxacin, tobramycin and cefotaxime Statistical analysis showed no significant differences in resistance of samples of different origins for drugs DX, CT, and IP. Considering the resistance to CI, the environmental samples were significantly more resistant than samples oral and extra-oral. For the drug TM, the oral samples were significantly more sensitive than the other samples. The irradiation of planktonic and biofilm cultures in the absence of TBO (L+S-), incubation with TBO alone (L-S+) and untreated control group (L-S-) had no significant effect on the viability of strains of S. marcescens studied (p <0.05). Significant decreases in bacterial viability was observed only when planktonic and biofilm culture of environmental strains, oral and extra-oral S. marcescens were exposed to toluidine blue O and LED light at the same time (L+S+). Significant reductions in bacterial counts were observed by antimicrobial photodynamic therapy ranging from 10-11 to 10-7.The association of TBO and light, with energy density 4,72 J cm-2, was effective in reducing the viability of bacterial strains in environmental, oral and extra-oral S. marcescens and can be a useful biotechnological tool in the control of bacterial resistance / Serratia marcescens se encontra largamente distribuída na natureza, mas tem emergido nos últimos anos como um importante patógeno nosocomial resistente a diversos antimicrobianos. Este estudo teve como objetivo verificar a susceptibilidade de isolados ambientais, orais e extra-orais de Serratia marcescens a diferentes antibióticos e avaliar a terapia fotodinâmica antimicrobiana na redução do crescimento bacteriano em culturas de células planctônicas e biofilme. O teste de susceptibilidade antimicrobiano E-test® foi realizado para as 55 cepas e o TFA para as 30 cepas mais resistentes aos antimicrobianos testados. O efeito antimicrobiano do azul de o-toluidina associado com 4,72 J cm-2 de luz emitida por um diodo (LED) foi avaliado. Antes e após os tratamentos, os inóculos bacterianos foram analisados com consideração do número de unidades formadoras de colônias. Considerando o perfil antimicrobiano observamos que das 55 cepas analisadas, 13 (23,63%) apresentaram resistência à doxiciclina, mas apenas um (1,81%) isolado apresentou resistência ao ciprofloxacino, outro à tobramicina e outro à cefotaxima; 24 (43,63%) cepas apresentaram sensibilidade intermediária à doxiciclina, todas foram sensíveis ao imipenem e a maioria foi sensível ao ciprofloxacino, à tobramicina e à cefotaxima. A análise estatística demonstrou não haver diferenças significativas no perfil de resistência das amostras de diferentes origens em relação as drogas DX, CT e IP. Considerando a resistência a CI, as amostras ambientais foram significativamente mais resistentes do que as amostras orais e extra-orais. Para a droga TM, as amostras orais foram significantemente mais sensíveis do que as demais amostras. A irradiação das culturas planctônicas e biofilmes na ausência de TBO (L+C-), a incubação com TBO sozinho (L-C+) e o grupo controle não tratado (L-C-) não apresentou efeitos significativos na viabilidade das cepas de S. marcescens estudadas (p < 0,05). Decréscimos significativos na viabilidade bacteriana foram observados somente quando cultura planctônica e biofilme de cepas ambientais, orais e extra-orais de S. marcescens foram expostas ao azul de orto toluidina e luz LED ao mesmo tempo (L+C+). Reduções significativas nas contagens bacterianas foram observadas pela Terapia Fotodinâmica Antimicrobiana com variação de 10-11 a 10-7. A associação de TBO e LED, com densidade de energia de 4,72 J cm-2 , foi efetivo na redução da viabilidade bacteriana em cepas ambientais, orais e extra-orais de S. marcescens podendo ser uma ferramenta biotecnológica útil no controle da resistência bacteriana
44

Desenvolvimento de fontes de radiação coerente na região azul com lasers semicondutores para experimentos de resfriamento e aprisionamento de átomos de cálcio / Development sources of coherent radiation in the blue region with semiconductors laser for experiments of coolong and trapping of neutral calcium atoms

Figueira, David da Silva Leocadio, 1980- 20 December 2004 (has links)
Orientador: Flavio Caldas da Cruz / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-06T01:07:38Z (GMT). No. of bitstreams: 1 Figueira_DaviddaSilvaLeocadio_M.pdf: 3869897 bytes, checksum: 4f234a84a87a86465d0b4e90fa141658 (MD5) Previous issue date: 2004 / Resumo: Esta tese apresenta o desenvolvimento de fontes de radiação coerente na região do azul baseadas em lasers semicondutores para excitar a transição de resfriamento e aprisionamento 1 S0-1P1 do Cálcio, em 423nm. Foi construído um laser de diodo em cavidade estendida emitindo em g =846 nm que foi empregado em uma configuração de Cavidade Estendida de Littman, estabilizada em freqüência pela técnica de Side-of-Fringe. Parte da potência deste laser foi amplificada por um amplificador óptico semicondutor. Potências superiores a 700mW em g =846nm foram obtidas. Parte desta potência do amplificador óptico (450mw) foi duplicada em frequência para g =423nm em um cristal de niobato de potássio(KNbO3), utilizado dentro de uma cavidade óptica ressonante com a freqüência do laser. A estabilização da cavidade óptica duplicadora de freqüência foi feita pela técnica de Hansch-Coulliaud . O sistema desenvolvido alcançou potências de 60mW de radiação coerente azul. Esta fonte laser portátil deverá ser utilizada para espectroscopia, resfriamento e aprisionamento de Cálcio / Abstract: This thesis presents the development of sources of coherent radiation in the blue region of the spectrum, based on semiconductors lasers, to excite the cooling and trapping 1S0-1P1 transition of neutral calcium atoms at 423nm. A diode laser emitting at g =846 nm was employed in an extended cavity Littman configuration, and stabilized in frequency by the Side-of-Fringe technique. Part of the laser power was amplified by an optical semiconductor amplifier. Output powers above 700mW at g =846nm were obtained. Part of this amplified power (450mW) was frequency doubled to g =423nm in a potassium niobate (KNbO3) crystal, placed inside a resonant optical cavity. The lock of the doubling optical cavity was made by the Hansch-Coulliaud technique. The developed system reached powers near 60mW of blue coherent radiation at 423nm. This portable laser source will be used for spectroscopy, cooling and trapping of calcium / Mestrado / Física / Mestre em Física
45

Efeito da agitação do EDTA por meio ultrassônico ou pelo laser diodo de alta potência quanto extrusão apical, alteração de temperatura, resistência à fratura radicular, e a variação de pH na estrutura dentinária. /

Oliveira, Luiz Fernando de Freitas. January 2020 (has links)
Orientador: Fábio Luiz Camargo Villela Berbert / Resumo: Objetivo: O objetivo desse estudo foi avaliar protocolos de agitação do EDTA aplicando dois diferentes tipos lasers de diodo de alta potência, comparando-os com os métodos de agitação convencional e com o ultrassom, quanto à extrusão apical, alteração de temperatura, resistência à fratura radicular e análise de pH na dentina radicular. Material e Métodos: Essa pesquisa experimental ex-vivo, utilizou 120 pré-molares inferiores, unirradiculados, com ráizes retas, com rizogênses completa e com tamanho radicular superior a 16mm, pré-selecionados por meio de radiografia digital. Suas coroas foram removidas, padronizando as raízes em 16 mm, seguido do preparo com a lima K#15 K#20 e o sistema reciproc R25, R40 e R50, 1 mm aquém do comprimento real do dente, com irrigação durante o preparo com NaOCl a 2,5%. Os espécimes foram distribuídos aleatoriamente em 6 grupos segundo protocolos de irrigação final: AD- água destilada (controle), CV- inundação com EDTA 17% e agitação com lima K #50, PUI- inundação com EDTA 17% agitado com ultrassom (Passive ultrasonic irrigation-PUI), PUI/CUI- inundação com EDTA 17% agitado com ultrassom (PUI) e irrigação com água destilada, agitada com ultrassom (Continuous ultrasonic irrigation-CUI), TL- inundação com EDTA 17% agitado com laser diodo Thera Lase Surgery, e GE- EDTA 17% agitado com laser diodo Gemini. Após irrigação final, todos os dentes foram irrigados com água destilada para remoção do EDTA. Resultados: Na avaliação da extrusão apical foi real... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The objective of this study was to evaluate EDTA agitation protocols by applying two different types of high-power diode lasers, comparing them with conventional agitation methods and with ultrasound, in relation to apical extrusion, temperature change, fracture resistance root and pH analysis in root dentin. Material and Methods: This ex-vivo experimental research used 120 lower premolars, uniradicular, with straight roots, with complete rhizogenesis and with root size greater than 16mm, pre-selected by means of digital radiography. Their crowns were removed, standardizing the roots by 16 mm, followed by preparation with the K # 15 K # 20 file and the reciproc system R25, R40 and R50, 1 mm below the actual length of the tooth, with irrigation during preparation with NaOCl to 2.5%. The specimens were randomly distributed into 6 groups according to final irrigation protocols: AD- distilled water (control), CV- flood with 17% EDTA and agitation with K # 50 file, PUI- flood with 17% EDTA agitated with ultrasound (Passive ultrasonic irrigation-PUI), PUI / CUI- flooding with 17% EDTA stirred with ultrasound (PUI) and irrigation with distilled water, stirred with ultrasound (Continuous ultrasonic irrigation-CUI), TL- flooding with 17% EDTA stirred with laser diode Thera Lase Surgery, and GE-EDTA 17% stirred with Gemini diode laser. After final irrigation, all teeth were irrigated with distilled water to remove EDTA. Results: In the evaluation of the apical extrusion, the... (Complete abstract click electronic access below) / Mestre
46

O uso de laser diodo de 830nm em cicatrizes pós-cirúrgicas de hérnia inguinal. Um estudo clínico / The use of 830nm diode laser in post-surgical scarring of inguinal hernia. A clinical study.

Carvalho, Rodrigo Leal de Paiva 06 May 2009 (has links)
Introdução: A Laserterapia de Baixa Intensidade (LTBI) é uma terapia que tem se mostrado eficiente na reparação tecidual em trabalhos com cultura celular e experimentos animais, mas existe uma escassez de trabalhos com cicatrização de incisões pós-cirúrgicas em humanos utilizando laser infravermelho GaAlAs de 830nm. O objetivo desse trabalho foi investigar a eficácia do laser infravermelho GaAlAs de 830nm no processo de cicatrização de incisão póscirúrgica de hérnia inguinal Métodos: 28 pacientes submetidos à cirurgia de hérnia-inguinal foram divididos randomicamente em grupo experimental (G1) e grupo controle (G2). O G1 recebeu tratamento com laser, sendo a primeira aplicação 24hs após a cirurgia e as demais dia sim dia não até um total de 4 aplicações. Ambos os grupos foram reavaliados após 6 meses por meio da Escala de cicatriz de Vancouver (ECV) e Escala visual analógica (EVA) e da espessura da cicatriz. As incisões foram irradiadas com laser diodo, =830 nm, 40 mW de potência de saída, 0,08cm² de diâmetro da ponteira de emissão, 26 segundos, 1,04J de energia por ponto e fluência de 13J/cm². Resultados: O G1 apresentou melhora significativa nas médias (p<0,05) da soma total da VSS 11 G1 2,14(±1,51) e G2 4,85(±1,87), na espessura G1 (0,11) e G2 (0,19) e na elasticidade da cicatriz G1 (0,14) e G2 (1,07). Conclusão: De acordo com os resultados obtidos nesse trabalho o tratamento com laser (830nm), usado na cicatrização de cirurgias de hérnia inguinal conseguiu melhorar a aparência e a qualidade da cicatriz seis meses após a incisão. / Background: Low Level Laser Therapy (LLLT) has been shown to be beneficial in the tissue repair process as shown in work done with tissue culture and animal experiments. However, there is a scarcity of work done with regard to post-surgical scarring of incisions in humans using infrared, 830nm, GaAlAs laser. The purpose of this study was to investigate the efficacy of an infrared, GaAlAs laser with a wavelength of 830nm in the post surgical scarring process after Inguinal Hernia Surgery. Method: 28 patients who underwent surgery for Inguinal Hernias were randomly divided into an Experimental Group (G1) and a Control Group (G2). The G1 received low level laser treatment (LLLT) with the first application being made 24 hours after surgery and then every other day for a total of 4 applications. Both Groups were re-evaluated after 6 months using the Vancouver Scar Scale (VSS), the Visual Analog Scale (VAS), and a measurement of scar thickness. The incisions were irradiated with an 830 nm diode laser operating with a continuous output power of 40 mW, spot size aperture of 0.08cm ², 26 seconds, an energy per point of 1.04J and energy density of 13J/cm ². Results: The G1 showed significantly better results; in the VSS totals (2.14±1.51) versus G2 (4.85±1.87), in the thickness measurements G1 (0.11 cm) versus G2 (0.19 cm), and in the pliability G1 (0.14) versus G2 (1.07). Conclusion: According to the results of this work LLLT (830nm) of Inguinal Hernia Scars resulted in better appearance and scar quality six months after surgery.
47

Dinâmica em freqüência de lasers semicondutores sob realimentação ótica ortogonal e aplicação: chaveamento todo-ótico em frequência

Sorrentino, Taciano Amaral 30 June 2010 (has links)
Made available in DSpace on 2015-05-14T12:14:19Z (GMT). No. of bitstreams: 1 parte1.pdf: 1564749 bytes, checksum: f636c3379c524ad8d77d3be5f44c4c36 (MD5) Previous issue date: 2010-06-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / We analyze the dynamics of semiconductor lasers radiation frequency when these lasers are subject to different conditions of optical feedback, and we demonstrate how it is possible to control the emission frequency using the different configurations explored. In the first system studied a semiconductor laser is fed back with light which polarization is orthogonal to the output polarization, spectrally filtered by a cesium atomic vapor. This system, besides presenting an effective technique to stabilize the laser frequency and reduce the laser linewidth, was the first to exhibit frequency bistable and multistable optical regimes with amplitude practically constant. This unique feature opens the way for applications in all-optical FM logical devices. The bistable and multistable regimes are interpreted through a phenomenological model, and, for the bistable regime, we discuss a rate equation model, built taking in account thermal effects and gain saturation. We also present an all-optical frequency switch, the first of his kind. The second system is used to investigate the behavior of the emission frequency of a semiconductor laser with an external cavity, inside which is placed an atomic filter. For different values of the injection current we observe the laser frequency locking in the atomic line, bistability and reproducible frequency instabilities. / Estudamos a dinâmica em frequência da radiação emitida por lasers semicondutores submetidos a diferentes condições de realimentação ótica e demonstramos como é possível o controle da frequência de emissão pelo uso das diferentes configurações exploradas. No primeiro sistema estudado, um laser semicondutor é realimentado por luz com polarização ortogonal á de saída, filtrada espectralmente por vapor atômico de césio. Além de apresentar uma técnica efetiva para estabilização da frequência laser e redução de largura de linha, esse foi o primeiro sistema a exibir regimes de biestabilidade e multiestabilidade ótica exclusivamente em sua frequência, ou seja, com amplitude constante. Essa característica única abre caminho para aplicações desta técnica em dispositivos lógicos FM do tipo tudo ótico . O aparecimento desses regimes é analizado através de um modelo fenomenológico e, para o caso biestável, construímos também um modelo de equações de taxa, onde levamos em conta efeitos térmicos e de saturação de ganho no laser semicondutor. Como aplicação dessa técnica apresentamos o funcionamento de uma chave em frequência do tipo tudo-ótico , a primeira deste gênero. O segundo sistema experimentalmente investigado foi concebido para produzir um comportamento dinâmico da frequência de um laser semicondutor com cavidade estendida quando um filtro atômico é posicionado dentro dessa cavidade. Para diferentes valores da corrente de injeção observamos o travamento da frequência laser na linha atômica, biestabilidade e instabilidades não aleatórias.
48

O uso de laser diodo de 830nm em cicatrizes pós-cirúrgicas de hérnia inguinal. Um estudo clínico / The use of 830nm diode laser in post-surgical scarring of inguinal hernia. A clinical study.

Rodrigo Leal de Paiva Carvalho 06 May 2009 (has links)
Introdução: A Laserterapia de Baixa Intensidade (LTBI) é uma terapia que tem se mostrado eficiente na reparação tecidual em trabalhos com cultura celular e experimentos animais, mas existe uma escassez de trabalhos com cicatrização de incisões pós-cirúrgicas em humanos utilizando laser infravermelho GaAlAs de 830nm. O objetivo desse trabalho foi investigar a eficácia do laser infravermelho GaAlAs de 830nm no processo de cicatrização de incisão póscirúrgica de hérnia inguinal Métodos: 28 pacientes submetidos à cirurgia de hérnia-inguinal foram divididos randomicamente em grupo experimental (G1) e grupo controle (G2). O G1 recebeu tratamento com laser, sendo a primeira aplicação 24hs após a cirurgia e as demais dia sim dia não até um total de 4 aplicações. Ambos os grupos foram reavaliados após 6 meses por meio da Escala de cicatriz de Vancouver (ECV) e Escala visual analógica (EVA) e da espessura da cicatriz. As incisões foram irradiadas com laser diodo, =830 nm, 40 mW de potência de saída, 0,08cm² de diâmetro da ponteira de emissão, 26 segundos, 1,04J de energia por ponto e fluência de 13J/cm². Resultados: O G1 apresentou melhora significativa nas médias (p<0,05) da soma total da VSS 11 G1 2,14(±1,51) e G2 4,85(±1,87), na espessura G1 (0,11) e G2 (0,19) e na elasticidade da cicatriz G1 (0,14) e G2 (1,07). Conclusão: De acordo com os resultados obtidos nesse trabalho o tratamento com laser (830nm), usado na cicatrização de cirurgias de hérnia inguinal conseguiu melhorar a aparência e a qualidade da cicatriz seis meses após a incisão. / Background: Low Level Laser Therapy (LLLT) has been shown to be beneficial in the tissue repair process as shown in work done with tissue culture and animal experiments. However, there is a scarcity of work done with regard to post-surgical scarring of incisions in humans using infrared, 830nm, GaAlAs laser. The purpose of this study was to investigate the efficacy of an infrared, GaAlAs laser with a wavelength of 830nm in the post surgical scarring process after Inguinal Hernia Surgery. Method: 28 patients who underwent surgery for Inguinal Hernias were randomly divided into an Experimental Group (G1) and a Control Group (G2). The G1 received low level laser treatment (LLLT) with the first application being made 24 hours after surgery and then every other day for a total of 4 applications. Both Groups were re-evaluated after 6 months using the Vancouver Scar Scale (VSS), the Visual Analog Scale (VAS), and a measurement of scar thickness. The incisions were irradiated with an 830 nm diode laser operating with a continuous output power of 40 mW, spot size aperture of 0.08cm ², 26 seconds, an energy per point of 1.04J and energy density of 13J/cm ². Results: The G1 showed significantly better results; in the VSS totals (2.14±1.51) versus G2 (4.85±1.87), in the thickness measurements G1 (0.11 cm) versus G2 (0.19 cm), and in the pliability G1 (0.14) versus G2 (1.07). Conclusion: According to the results of this work LLLT (830nm) of Inguinal Hernia Scars resulted in better appearance and scar quality six months after surgery.
49

Fotocoagulação de acordo com o protocolo ETDRS modificado versus laser diodo sublimiar em micropulsos para tratamento de edema macular diabético: Ensaio clínico-comparativo / Randomized Clinical Trial Evaluating mETDRS versus Normal or High-Density Micropulse Photocoagulation for Diabetic Macular Edema

Lavinsky, Daniel [UNIFESP] 29 June 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:15Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-29 / Objetivo: Comparar a fotocoagulação focal e em grade de acordo com o protocolo do Early Treatment Diabetic Retinopathy Study modificado (mETDRS) utilizando fotocoagulação com laser diodo 810nm sublimiar em micropulsos e densidade normal (FSM-DN) ou aumentada (FSM-DA) no tratamento do edema macular diabético (EMD). Métodos: Foi conduzido um estudo randomizado, controlado, prospectivo, duplo mascarado com pacientes não tratados com EMD e melhor acuidade visual corrigida (MAVC), pior que 20/40 e melhor que 20/400. Pacientes foram aleatorizados para receber fotocoagulação de acordo com o protocolo mETDRS (42 pacientes), FSM-DN (39 pacientes) ou FSM-DA (42 pacientes). Imediatamente antes do tratamento, 3, 6, bem como 12 meses após ele, todos os pacientes foram submetidos a exame oftalmológico, MAVC, retinografia colorida, angiografia fluorescente e tomografia de coerência óptica (OCT). Efeitos adversos nas diferentes técnicas de fotocoagulação foram observados durante o acompanhamento do estudo. Resultados: Durante o acompanhamento, todos os grupos apresentaram redução da espessura macular central, com diminuição no grupo FSM-DA de 93μm em três meses, 117μm em seis meses e 144μm em nove meses, comparado à redução de 67, 94 e 112μm em três, seis e nove meses respectivamente, no grupo mETDRS. Já o grupo FSM-DN apresentou redução de 20μm em três e seis meses e 34μm em nove meses, significativamente inferior aos grupos FSM-DA e mETDRS. Em relação à acuidade visual, houve melhora da MAVC gradual em três, seis e nove meses nos grupos FSM-DA e mETDRS sem diferenças estatisticamente significativas entre estes grupos, porém ambos superiores ao grupo FSM-DN, que não apresentou mudança na acuidade visual nesses períodos. Em doze meses, o grupo FSM-DA teve o melhor resultado em termos de MAVC (0,25 logMAR), seguido do grupo mETDRS (0,08 logMAR), enquanto o grupo FSM-DN não apresentou melhora significativa na MAVC (0,03 logMAR) (p<0,001). Todos os grupos apresentaram redução estatisticamente significativa da espessura macular central no OCT (p<0,001). O grupo FSM-DA demonstrou a maior redução (154μm), porém não foi estatisticamente significativa em relação ao grupo mETDRS (126μm; p=0,75). Não foram observados efeitos adversos graves nas diferentes formas de tratamento. Conclusão: Em um ano, a resposta clínica do grupo FSM-DA foi superior aos grupos mETDRS e FSM-DN, baseada na medida de espessura central da mácula e acuidade visual. Estes dados sugerem que a técnica de FSM-DA pode ser utilizada como conduta preferível para o tratamento de EMD, porém estudos clínicos multicêntricos são necessários para confirmar estes resultados. / Purpose: To compare modified Early Treatment Diabetic Retinopathy Study (ETDRS) focal/grid laser photocoagulation with normal-density (ND-SDM) or high-density (HD-SDM) subthreshold diode-laser micropulse photocoagulation for the treatment diabetic macular edema (DME). Methods: We conducted a prospective, randomized, controlled, double-masked clinical trial with patients with previously untreated DME and best corrected visual acuity (BCVA) worse than 20/40 and better than 20/400. Patients were randomized to receive either modified ETDRS focal / grid photocoagulation (42 patients), ND-SDM (39 patients) or HD-SDM (42 patients). Before treatment and 3, 6 and 12 months after treatment, all patients underwent ophthalmic examinations, BCVA, color fundus photography, fluorescein angiography and optical coherence tomography (OCT). Results: At 12 months, the HD-SDM group had the best improvement in BCVA (0.25 logMAR), followed by the modified ETDRS group (0.08 logMAR), while no improvements were seen in the ND-SDM group (0.03 logMAR). All groups showed statistically significant progressive reduction of CMT throughout the study (p<0.001). The HD-SDM group exhibited the greatest CMT reduction (154 μm), which was not significantly different from that of the modified ETDRS group (126 μm; p=0.75). Conclusions: At 1 year, the clinical performance of HD-SDM was superior to that of the modified ETDRS photocoagulation technique based on the anatomic and functional measures of improvement used in this investigation. A rationale for this treatment modality as a preferable approach is suggested, and the precise role of sub-threshold micropulse laser treatment may become more defined as experience grows, guided by optimized treatment guidelines and more comprehensive trials. / TEDE / BV UNIFESP: Teses e dissertações
50

Efeito fotobiomodulador da terapia laser de baixa intensidade na transição inflamação-reparo em modelo de lesão pulmonar / Effect of low level laser therapy in the transition between inflammation and repair in a model of lung injury

Cury, Vivian 22 October 2013 (has links)
A terapia laser de baixa intensidade (LLLT) é capaz de modular a resposta inflamatória em vários modelos experimentais, reduzindo o infiltrado de células do sistema imune e a secreção de mediadores químicos. Estudos prévios sugerem sua utilidade também no tratamento da lesão pulmonar aguda (LPA), condição caracterizada por intensa reação inflamatória em vias aéreas distais. Assim, considerando os efeitos anti-inflamatórios do laser e a fisiopatologia da LPA, formulamos a hipótese de que a LLLT 660 nm, 10 J/cm2, poderia modular o processo inflamatório nessa patologia favorecendo a transição inflamação-reparo. Foram utilizados camundongos C57BL distribuídos aleatoriamente em 4 grupos: PBS- instilado com PBS intratraqueal; PBS+LLLT- irradiado com LLLT 6 horas após instilação intratraqueal de PBS; LPS- instilado com LPS (5 mg/kg); LPS+LLLT- irradiado com LLLT 6 horas após instilação intratraqueal de LPS. Observou-se que a instilação de LPS intratraqueal levou a um aumento do número de células inflamatórias tanto na região peribronquiolar quanto no lavado broncoalveolar (LBA), detectado na histologia pulmonar e pela expressão de F4/80. Houve também aumento da transcrição e secreção de citocinas (TNF-alfa, IL-1beta, IL-6, IL-10) e quimiocinas (MCP-1) (detectadas por PCR quantitativo e ELISA). A aplicação de LLLT 6 horas após a instilação de LPS causou uma significativa diminuição tanto no influxo de células inflamatórias quanto na secreção de mediadores. Em seguida, foram caracterizadas as populações de macrófagos presentes no tecido pulmonar e observou-se nos animais do grupo LPS+LLLT, comparados ao grupo LPS, uma diminuição na expressão de mRNA de HIF-1alfa e aumento para arginase 1, sugerindo um predomínio da população de macrófagos M2. Esse efeito da LLLT foi também testado em populações de macrófagos peritoneais estimulados com LPS em cultura, porém, embora houvesse diminuição da produção de citocinas e quimiocinas, não foram observadas diferenças nos marcadores de polarização dessas células / A low-level laser therapy (LLLT) is able to modulate the inflammatory response in several experimental models, reducing the infiltration of immune system cells and the secretion of chemical mediators. There are some previous studies suggesting also useful in the treatment of acute lung injury (ALI), a condition characterized by an intense inflammatory reaction in the distal airways. Considering the anti-inflammatory effects of laser and the pathophysiology of ALI, we hypothesized that LLLT 660 nm, 10 J/cm2, could modulate the inflammatory process in this disease favoring the transition between inflammation and repair. C57BL mice were divided into four groups: PBS - intratracheal instillation of PBS; PBS+LLLT - irradiated with LLLT 6 hours after intratracheal instillation of PBS; LPS - intratracheal instillation of LPS (5 mg/kg); LPS+LLLT - irradiated with LLLT 6 hours after intratracheal instillation of LPS. Animals were sacrificed 24 hours after injury. Intratracheal LPS inoculation induced a marked increase in the number of inflammatory cells in perivascular and alveolar spaces (detected by lung histology and in bronchoalveolar lavage), and F4/80 expression (macrophage marker). There was also an increase in the expression and secretion of cytokines (TNF-alfa, IL-1beta, IL-6, IL-10) and chemokine (MCP-1) detected by ELISA and quantitative PCR. The LLLT application 6 hours after LPS induced a significant decrease in both of the inflammatory cells influx and mediators secretion. Then, we characterized the macrophages populations in lung tissue and we observed that in the LPS+LLLT group the expression of HIF-1alfa mRNA was reduced while arginase 1 was increased, which suggested that the M2 macrophages were predominant. The LLLT effect was also tested on peritoneal macrophage population in culture stimulated with LPS and there was decreased of cytokines and chemokine production, however any difference in polarization markers was found

Page generated in 0.1011 seconds