• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 23
  • 6
  • Tagged with
  • 65
  • 32
  • 29
  • 13
  • 12
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Elastographie ultrasonore des tissus mous du membre inférieur en vue de la caractérisation des effets mécaniques de dispositifs médicaux textiles / Elastographic and biomechanical studies of soft tissues of the leg – Application to elastic compression

Frauziols, Fanny 14 December 2015 (has links)
La compression élastique de la jambe est le traitement de référence des pathologies liées à l’insuffisance veineuse. Bien que l’efficacité ne soit plus à prouver, les objectifs thérapeutiques restent non atteints pour certains patients. Un objectif de la compression élastique est la réduction de la pression pariétale des veines afin de rétablir ou d’augmenter le retour du sang vers le cœur par une transmission de pression au travers des tissus mous. Ce mécanisme est complexe et peut être prédit par des modèles éléments finis personnalisés. Pour être personnalisés, ces modèles doivent prendre en compte la géométrie et la carte des propriétés mécaniques du sujet.Dans cette étude, on développe deux méthodologies permettant d’identifier les propriétés mécaniques des tissus mous. Dans un premier temps, on mesure par élastographie ultrasonore par onde de cisaillement la distribution du module élastique au sein des tissus mous superficiels. Dans un deuxième temps, on identifie par une méthode inverse les propriétés mécaniques des tissus mous profonds. Cette méthode associe l’acquisition de données d’un essai expérimental de compression localisée de la jambe à un modèle éléments finis bidimensionnel. Ces deux méthodologies nous permettent d’évaluer l’hétérogénéité des propriétés mécaniques de la peau au fascia cruris et de caractériser le comportement non-linéaire des tissus mous profonds. Enfin, les résultats de ces deux méthodologies sont couplés afin de générer un modèle biomécanique de la jambe sous compression élastique pour prédire la distribution de pression au sein des tissus mous pour quatre sujets sains. / Elastic compression of the leg is a widely used treatment in case of pathologies related to venous insufficiency. Its benefits are not to be proven, but still, for some patients, the therapeutic goal is not reached. One goal of this treatment is to reduce transmural pressure applied to veins in order to restore or increase blood return to the heart by the transmission of the external pressure through soft tissues. This is a complex mechanism that can be predicted by patient-specific finite element models. To be patient-specific, these models must take into account the geometry and the distribution of mechanical properties of each subject.In this study, two methodologies are developed to identify the mechanical properties of soft tissues. First, the elastic modulus distribution inside the superficial soft tissues is measured by shear wave ultrasound elastography. Second, the mechanical properties of deep soft tissues are identified through an inverse method combining the data acquired from an experimental localized compression of the leg to a bi-dimensional finite element model.These two methodologies allow to evaluate the mechanical properties heterogeneity from the skin to the fascia cruris and to characterize the non-linear behaviour of deep soft tissues. Finally, the results from both methodologies are brought together to generate a biomechanical model of the leg under elastic compression to predict pressure distribution inside soft tissues for four healthy subjects.
52

Reconstitution faciale par imagerie 3d : variabilité morphométrique et mise en oeuvre informatique

Guyomarc'h, Pierre 28 November 2011 (has links)
La reconstitution faciale a pour but de restituer le visage d’un individu à partir de la morphologie de son crâne. Cette technique est utilisée en anthropologie médico-légale pour apporter de nouveaux témoignages dans l’identification de restes humains. Les objectifs de thèse sont d’établir une base de données crânio-faciale 3D de Français grâce à l’imagerie médicale, de tester les règles traditionnelles de reconstitution, et de quantifier les corrélations morphologiques entre tissus osseux et cutanés. Des examens hospitaliers par scanner tomodensitométrique (18 – 96 ans ; sexe ratio 1,16:1) ont été traités avec le logiciel TIVMI pour reconstruire avec précision les surfaces osseuses et cutanées. Plus de 200 points de repère ont pu être positionnés sur 500 individus, en suivant un protocole précis (répétabilité et reproductibilité vérifiées). L’extraction de distances Euclidiennes a permis de tester plusieurs règles traditionnelles, et d’étudier la spécificité et la variabilité des épaisseurs de tissus mous. Parallèlement, les coordonnées 3D des points ont été analysées par morphométrie géométrique. Les covariations entre groupes de points osseux et cutanés ont pu être quantifiées, ainsi que les asymétries, allométries, et influences de l’âge et du sexe sur les variations de conformation. Ces résultats ont permis l’élaboration d’une méthode d’estimation de la position des points de repère du visage, et la création (en collaboration avec le LaBRI) d’un module de reconstitution faciale nommé AFA3D. Basé sur le principe de déformation d’un visage synthétique, ce logiciel restitue la forme la plus probable du visage en fonction de la position de 78 points crâniométriques. / Facial approximation aims at the production of a face based on the skull morphology. This technique is performed in forensic anthropology to bring new testimonies in cases of human remains identification. The goals of this research are to establish a database of French skulls and faces in 3D through medical imaging, to test traditional guidelines, and to quantify the morphological correlations between soft and hard tissues. Computed tomography exams, collected in French hospitals (18 – 96 years; sex ratio 1.16:1), were treated with TIVMI software to reconstruct accurately the bone and skin surfaces. More than 200 landmarks have been placed on 500 subjects, following a protocol which repeatability and reproducibility have been checked. The extraction of Euclidian distances allowed testing traditional guidelines, and studying specificity and variability of soft tissue depths. In parallel, the 3D coordinates were analyzed with geometric morphometrics. Covariations between groups of bone landmarks and groups of skin landmarks were quantified, along with asymmetry, allometry, and influences of age and sex on the shape changes. These results allowed for the creation of a method to estimate the position of skin landmarks, and for the development of a facial approximation module in TIVMI, called AFA3D (in collaboration with the LaBRI). Based on the warping of a synthetic face, this software renders the most probable face depending on the position of 78 cranial landmarks.
53

Biomécanique des tissus mous de la jambe humaine sous compression élastique / Biomechanics of soft tissues of human leg under elastic compression

Dubuis, Laura 12 December 2011 (has links)
La compression élastique (CE) est un traitement médical qui est prescrit en cas d'insuffisance veineuse. Récemment, la CE rencontre aussi un certain succès auprès des sportifs pour la récupération. Cependant, malgré l’utilisation de plus en plus massive de la CE, son action biomécanique sur le membre inférieur n'est pas encore bien caractérisée. Pour contribuer à cette caractérisation, un modèle biomécanique 3D des tissus mous de la jambe sous CE a été développé et appliqué à un panel de sujets. Chaque modèle est personnalisé : la géométrie est reconstruite à partir des images tomographiques 3D de la jambe de chaque sujet et les conditions aux limites reproduisent fidèlement la pression localement appliquée par la CE sur la peau. De plus, les propriétés hyper-élastiques des tissus mous sont identifiées pour chaque sujet par recalage du modèle. Une méthode de recalage originale a été spécifiquement développée et mise en œuvre pour cette application : elle consiste à utiliser les images tomographiques 3D de la jambe déformée comme données expérimentales pour le recalage. Finalement, le modèle donne accès au champ de pression transmis par la CE aux tissus mous internes. Les principales conclusions sont que le champ de pression à l'intérieur de la jambe n'est pas transmis uniformément et qu'il y a de fortes variabilités inter-sujets. En outre, le modèle permet d'obtenir des indications sur le confort et l'efficacité de la CE. Il a ainsi été possible de montrer que l'intensité des pressions maximales subies par les tissus mous de la jambe est inversement proportionnelle à l’épaisseur du tissu adipeux. Les principales perspectives du travail concernent la validation clinique de ces conclusions sur un nombre significatif de sujets, puis leur exploitation en vue d’améliorer les traitements. / Elastic compression (EC) is a medical treatment prescribed in case of venous insufficiency. Recently, EC is also employed for recovery after efforts in sports. Nevertheless, despite the more and more common use of EC, its biomechanical action onto the lower limb remain partially unknown . To address this issue, a 3D biomechanical model of the soft tissues of the leg under EC has been developed and applied on a group of subjects. Each model is patient-specific: the geometry is reconstructed from the 3D CT-scan images of each subject’s legs and the boundary conditions are prescribed according to the local pressure applied by the EC onto the skin. Furthermore, the hyper-elastic properties of the soft tissues are identified for each subject using an inverse approach. The inverse approach is original: it consists in using the 3D CT-scan images of the deformed leg as experimental data for calibrating the model. The resulting model provides the pressure fields in the internal soft tissues induced by the EC. The main conclusions are that the pressure is not transmitted evenly and that significant inter-subject variability exists. Moreover, it is shown that the magnitude of the pressure undergone by the soft tissues is inversely proportional to the thickness of adipose tissues. The main perspectives of this work are to validate the conclusions on a significant number of subjects and to continue improving the treatments of venous insufficiency by EC.
54

Dynamique de la fermeture des trous épithéliaux en utilisant des techniques de micromécanique et de microfabrication / Dynamics of epithelial gap closure using microfabrication and micromechanical approaches

Anon, Ester 05 October 2012 (has links)
Les cellules peuvent migrer sous différentes conditions qui dépendent de l’environnement biochimique ou mécanique. Connaître les mécanismes de la migration, les protéines impliquées et leur régulation est essentiel pour comprendre les processus de morphogénèse ou certaines situations pathologiques. Dans ce contexte, la migration collective des cellules est un processus clé qui intervient pendant le développement ainsi que dans la vie adulte. Elle joue un rôle très important pour la formation et l’entretien des couches épithéliales, notamment au cours du développement embryonnaire et pendant la cicatrisation des trous épithéliaux résultant, par exemple, d’une blessure. Lorsque l’épithélium présente une discontinuité, des mécanismes actifs qui impliquent une migration coordonnée des cellules sont nécessaires pour préserver l’intégrité des tissus. Dans ce travail, nous avons étudié les mécanismes impliqués dans la fermeture des trous dans un épithélium. Pour des blessures de faible taille, le mode de fermeture dit de purse string est souvent évoqué, impliquant la contraction d’un anneau contractile d’acto-myosine qui ferme la blessure. Pour des blessures de tailles plus importantes, il est courant d’observer un mécanisme différent conduisant { la migration active des cellules du bord qui couvrent la surface “libre”.Pour étudier ces aspects de manière quantitative et reproductible, nous avons développé une nouvelle méthode basée sur des techniques de microfabrication et de lithographie dite « molle » qui permet de faire une étude quantitative de la fermeture des trous épithéliaux. Nous avons fabriqué des substrats de micropiliers de diamètre et de forme variés dans les quels les cellules sont libres de pousser entre les microstructures. Lorsqu’elles sont parvenues à confluence, on retire le substrat qui laisse apparaître des trous contrôlés.De cette manière, nous avons observé que les cellules épithéliales forment des lamellipodes pour la fermeture de ces trous. Le mécanisme de fermeture dépend de la taille des trous et nous avons pu observer différents régimes en fonction de diamètre des piliers. Les trous petits (de la taille d’une seule cellule) sont fermés par un mécanisme passif alors que la fermeture de trous plus larges nécessite un mécanisme actif de migration conduisant à la formation de lamellipodes et à des modes de migration collective. Par la suite, nous nous sommes intéressés à l’aspect mécanique de la fermeture des trous épithéliaux. Pour cela, nous avons utilisé un système d’ablation laser pour rompre quelques cellules dans une monocouche épithéliale. Nous avons alors mesuré les forces de traction que les cellules exercent au substrat et leur évolution temporelle et spatiale. Nous avons pu mettre en évidence différents modes de traction: au début, les cellules exercent des forces de traction importantes sur leur substrat pour laisser place à des contraintes mécaniques qui sont davantage issues d’un processus collectif au travers de la formation d’un câble multicellulaire qui les relie les cellules de bord entre elles. En conclusion, ce travail nous a permis d’obtenir des informations sur les mécanismes dynamiques de fermeture des tissus épithéliaux qui sont évidemment impliqués dans la cicatrisation des blessures mais aussi dans certains problèmes de malformations congénitales lors l’embryogenèse. / Most cells migrate under the appropriate conditions or stimuli; understanding the mechanisms of migration, the players involved, and their regulation, is pivotal to tackle the pathological situations where migration becomes an undesired effect. While largely overshadowed by the study of single cell migration, collective cell migration is a very relevant process that takes place during development as well as in adult life. Collective migration is very relevant for the formation and maintenance of epithelial layers: extensive migratory processes occur during the shape of the embryo, as well as during the healing of a skin incision in the adult. When openings or discontinuities appear in the epithelia, it is crucial that the appropriate mechanisms are activated.In the present work we attempt at deciphering what are the mechanisms involved in gap closure. Until now, most of the literature concerning the subject has reported contradictory results, mainly arising from the complexity of the process and the lack of systematic analysis. We have designed a novel approach to address epithelial gap closure under well-defined and controlled conditions. By using our gap patterning method, we have observed that epithelial cells extend lamellipodia when exposed to a newly available space. Interestingly, we found that the closure of such gap depends on the size: small gaps are closed by a passive physical mechanism, while large gaps are closed through a Rac-dependent cell crawling mechanism, in a collective migration-like manner. 11Abstract (English)Most cells migrate under the appropriate conditions or stimuli; understanding the mechanisms of migration, the players involved, and their regulation, is pivotal to tackle the pathological situations where migration becomes an undesired effect. While largely overshadowed by the study of single cell migration, collective cell migration is a very relevant process that takes place during development as well as in adult life. Collective migration is very relevant for the formation and maintenance of epithelial layers: extensive migratory processes occur during the shape of the embryo, as well as during the healing of a skin incision in the adult. When openings or discontinuities appear in the epithelia, it is crucial that the appropriate mechanisms are activated.In the present work we attempt at deciphering what are the mechanisms involved in gap closure. Until now, most of the literature concerning the subject has reported contradictory results, mainly arising from the complexity of the process and the lack of systematic analysis. We have designed a novel approach to address epithelial gap closure under well-defined and controlled conditions. By using our gap patterning method, we have observed that epithelial cells extend lamellipodia when exposed to a newly available space. Interestingly, we found that the closure of such gap depends on the size: small gaps are closed by a passive physical mechanism, while large gaps are closed through a Rac-dependent cell crawling mechanism, in a collective migration-like manner. Next, we also addressed the mechanical component of epithelial gap closure. In this study, we took advantage of a laser-ablation system to disrupt some cells within an epithelial monolayer, and study how the remaining cells sealed that gap. By measuring the traction forces that cells exert on the substrate along the closure, we observed that cells first pulled on the substrate to propel themselves. By the last steps of closure, there is a transition in the direction of the force, so that cells are pulled to the center of the gap due to the assembly of a supracellular actin cable. Altogether, this work provides valuable knowledge on the current understanding of the mechanisms accounting for epithelial gap closure. We believe that a better comprehension of these mechanisms can help to shed light in clinically relevant situations where epithelial gap closure is impaired.
55

Contribution « K » à l'effet biologique des rayonnements ionisants

Boissière, Arnaud 08 September 2004 (has links) (PDF)
Le but de ce travail est de déterminer l'importance des ionisations « K » sur l'ADN en tant qu'événements physiques critiques à l'origine des effets biologiques des rayonnements ionisants en particulier dans les cellules humaines. Les rayons X ultra-mous sont utilisés comme sonde des événements d'ionisations de cœur. Un test décisif consiste à comparer les effets biologiques à 250eV et 350eV (avant et après le seuil K du carbone). Les résultats montrent un fort accroissement de l'efficacité biologique pour l'inactivation cellulaire et la production d'aberrations chromosomiques d'échange au passage du seuil K du carbone, corrélé avec celui des événements de cœur produits dans les atomes de l'ADN. L'irradiation en ions lourds a permis de retrouver le comportement paradoxal des sections efficaces d'inactivation cellulaire en fonction du TEL. La contribution des événements « K » à l'inactivation cellulaire des rayonnements usuels de bas TEL est estimée à ~75%.
56

Contribution à l'étude des équations de Boltzmann, Kac et Keller-Segel à l'aide d'équations différentielles stochastiques non linéaires

Godinho, David 25 November 2013 (has links) (PDF)
L'objet de cette thèse est l'étude de l'asymptotique des collisions rasantes pour les équations de Kac et de Boltzmann ainsi que l'étude de la propagation du chaos pour l'équation de Keller-Segel dans un cadre sous-critique à l'aide d'équations différentielles stochastiques non linéaires. Le premier chapitre est consacré à l'équation de Kac avec un potentiel Maxwellien. Nous commençons par donner une vitesse de convergence explicite (que l'on pense être optimale) dans le cadre de l'asymptotique des collisions rasantes. Puis nous approchons la solution de l'équation de Kac dans le cadre général, ce qui nous permet de montrer la propagation du chaos pour un système de particules vers cette dernière de manière quantitative. Dans le deuxième chapitre, nous étudions l'asymptotique des collisions rasantes pour l'équation de Boltzmann avec des potentiels mous et de Coulomb. Nous donnons là encore des vitesses de convergence explicites (mais non optimales). Enfin dans le troisième et dernier chapitre, nous montrons la propagation du chaos pour l'équation de Keller-Segel dans un cadre sous-critique. Pour cela, nous utilisons des arguments de compacité (tension du système de particules).
57

Caractérisation des tissus biologiques mous par diffusion multiple de la lumière

ZERRARI, Naoual 18 March 2014 (has links) (PDF)
La diffusion multiple de la lumière(DWS) est une technique qui permet de sonder la dynamique interne de milieux opaques et concentrés à des fréquences élevées. Elle a été utilisée pour déterminer les propriétés viscoélastiques de ces milieux. Elle a l'avantage d'être non destructive, rapide et sensible. Ce travail a pour objectif l'étude des tissus biologiques mous par DWS. La première étape est la mise en place du dispositif expérimental. Afin d'évaluer les limites de la technique, des études successives ont été réalisées sur des matériaux de complexité croissante (une suspension, le lait et une mousse) tendant vers la complexité structurale des tissus biologiques. Pour la suspension et le lait, la théorie de DWS peut s'appliquer et permet de mesurer avec une bonne précision leur viscosité. Les limites de DWS pour évaluer la viscosité sont atteintes avec la mousse dont la structure complexe est proche de celle des tissus biologiques. Enfin, le cortex rénal, le parenchyme hépatique et le cerveau de porc ont été étudiés. La théorie appliquée pour les milieux précédents ne permet pas de remonter à leur viscosité. Mais la DWS a permis de suivre leur microstructure au cours de la déshydratation et de la dégénérescence. Pour tous ces milieux la répétabilité, la reproductibilité, la variabilité et l'effet des conditions expérimentales ont été évalués. La DWS pourrait être utilisée pour étudier l'effet de la température et de la congélation sur le spectre de DWS des tissus biologiques ou combinée à la rhéologie pour suivre l'évolution des spectres de DWS au cours d'un cisaillement
58

Multi-body optimization method for the estimation of joint kinematics : prospects of improvement / Méthode d’optimisation multi-segmentaire pour l’estimation de la cinématique articulaire : propositions d’amélioration

Richard, Vincent 28 June 2016 (has links)
L'analyse du mouvement humain s'appuie généralement sur des techniques de suivi de marqueurs cutanés pour reconstruire la cinématique articulaire. Cependant, ces techniques d'acquisition présentent d'importantes limites dont les " artefacts de tissus mous " (i.e., le mouvement relatif entre les marqueurs cutanés et le squelette sous-jacent). La méthode d'optimisation multi-segmentaire viseà compenser ces artefacts en imposant aux trajectoires de marqueurs les degrés de liberté d'un modèle cinématique prédéfini. Les liaisons mécaniques modélisant classiquement les articulations empêchent toutefois une estimation satisfaisante de la cinématique articulaire. Cette thèse aborde des perspectives d'amélioration de la méthode d'optimisation multi-segmentaire pour l'estimation de la cinématique articulaire du membre inférieur,à travers différentes approches : (1) la reconstruction de la cinématique par suivi de la vitesse angulaire, de l'accélération et de l'orientation de centrales inertiellesà la place du suivi de marqueurs, (2) l'introduction d'un modèle articulaire élastique basé sur la matrice de raideur du genou, permettant une estimation physiologique de la cinématique articulaire et (3) l'introduction d'un modèle des artefacts de tissus mous " cinématique-dépendant ", visantà évaluer et compenser les artefacts de tissus mous simultanément avec l'estimation la cinématique articulaire. Ce travail a démontré la polyvalence de la méthode d'optimisation multi-segmentaire. Les résultats obtenus laissent espérer une amélioration significative de cette méthode qui devient de plus en plus utilisée en biomécanique, en particulier pour la modélisation musculo-squelettique / Human movement analysis generally relies on skin markers monitoring techniques to reconstruct the joint kinematics. However, these acquisition techniques have important limitations including the "soft tissue artefacts" (i.e., the relative movement between the skin markers and the underlying bones). The multi-body optimization method aims to compensate for these artefacts by imposing the degrees of freedom from a predefined kinematic model to markers trajectories. The mechanical linkages typically used for modeling the joints however prevent a satisfactory estimate of the joint kinematics. This thesis addresses the prospects of improvement of the multi-body optimization method for the estimation of joint kinematics of the lower limb through different approaches: (1) the reconstruction of the kinematics by monitoring the angular velocity, the acceleration and the orientation of magneto-inertial measurement units instead of tracking markers, (2) the introduction of an elastic joint model based on the knee stiffness matrix, enabling a physiological estimation of joint kinematics and (3) the introduction of a "kinematic-dependent" soft tissue artefact model to assess and compensate for soft tissue artefact concurrently with estimating the joint kinematics. This work demonstrated the versatility of the multi-body optimization method. The results give hope for significant improvement in this method which is becoming increasingly used in biomechanics, especially for musculoskeletal modeling
59

Design of mechanoresponsive surfaces and materials / Conception des surfaces et des matériaux mécano-répondants

Rios Neyra, César 26 September 2013 (has links)
Le but de ma thèse a été de concevoir des matériaux chimio-mécano répondants, des matériaux capables de permettre une transformation chimique réversible lorsqu’ils sont soumis à un stress mécanique. Tous les systèmes conçus ont été développés sur des substrats en silicone. Une première approche a consisté à créer des surfaces à sites cryptiques où une biotine est enfouie dans des brosses de chaines de poly(éthylène glycol). Le système streptavidine/biotine a été utilisé comme modèle. Ces surfaces sont anti-adsorbantes à la streptavidine sauf lorsqu’elles sont étirées à 50% où la biotine est reconnue mais les surfaces sont non réversibles. Dans une seconde approche, nous avons modifiés la surface du silicone par adsorption d’une multicouche de polyélectrolytes. Cette stratégie est basée sur la réticulation covalente du film par l’enzyme β-galactosidase modifiée. Nous sommes ainsi parvenus à créer une surface présentant une activité catalytique modulable par l’étirement mécanique, et ce, d’une façon partiellement réversible. Ce travail représente le premier exemple d’un système où une contrainte mécanique imposée à un matériau permet la déformation conformationnelle d’une enzyme et ainsi la diminution de l’activité catalytique. Dans une dernière approche, nous avons conçu un système mixte composé d’un substrat de silicone sur lequel un gel de polyacrylamide est greffée de façon covalente. Des enzymes ou des mécanophores pourront ainsi être inclus dans le réseau polymérique du gel de polyacrylamide et être étirés. Nous sommes parvenus à préparer de tels systèmes où l’hydrogel reste solidaire du film de silicone, sans apparition de craquelures jusqu’à 50%d’étirement. / The goal of my PhD was to develop new routes to design chemo-mechanoresponsive materials, materials that respond chemically to a mechanical stress, in a reversible way. All the systems designed during my PhD thesis were based on the functionalization of silicone sheets. First we created cryptic site surfaces by embedding biotin ligands into PEG brushes. The couple streptavidin/biotin was used as a model system. At rest, the surface so-prepared was antifouling and biotin ligands were specifically recognized by the streptavidin when the surface was stretched at 50%. Unfortunately, in this first approach, the mechanosensitive surface did not lead to a reversible process. In a second approach, we modified the silicone surface by using the polyelectrolyte multilayer (PEM) film deposition. This strategy was based on the covalent cross-linking of modified enzyme, the β-galactosidase, into the PEM. We succeeded in modulating the enzyme activity in the film under stretching and this approach appears as partially reversible under stretching/unstretching cycles. This work represents the first reported system where enzymatic activity can be modulated by stretching due to modulation of the enzyme conformation. In a last approach, we also designed a mixed system consisting of a silicone sheet onto which a polyacrylamide hydrogel is covalentlyattached with the goal to create a stretchable gel into which one can covalently attach enzymes or chemical mechanophores. These enzymes or mechanophores can thus be put under mechanical stress. We succeeded in creating a system that can be stretched up to 50% without detachment of the gel from the silicone and without inducing cracks in the gel.
60

Caractérisation des tissus biologiques mous par diffusion multiple de la lumière / Characterization of soft biological tissues by diffusing wave spectroscopy

Zerrari, Naoual 18 March 2014 (has links)
La diffusion multiple de la lumière(DWS) est une technique qui permet de sonder la dynamique interne de milieux opaques et concentrés à des fréquences élevées. Elle a été utilisée pour déterminer les propriétés viscoélastiques de ces milieux. Elle a l'avantage d'être non destructive, rapide et sensible. Ce travail a pour objectif l'étude des tissus biologiques mous par DWS. La première étape est la mise en place du dispositif expérimental. Afin d'évaluer les limites de la technique, des études successives ont été réalisées sur des matériaux de complexité croissante (une suspension, le lait et une mousse) tendant vers la complexité structurale des tissus biologiques. Pour la suspension et le lait, la théorie de DWS peut s'appliquer et permet de mesurer avec une bonne précision leur viscosité. Les limites de DWS pour évaluer la viscosité sont atteintes avec la mousse dont la structure complexe est proche de celle des tissus biologiques. Enfin, le cortex rénal, le parenchyme hépatique et le cerveau de porc ont été étudiés. La théorie appliquée pour les milieux précédents ne permet pas de remonter à leur viscosité. Mais la DWS a permis de suivre leur microstructure au cours de la déshydratation et de la dégénérescence. Pour tous ces milieux la répétabilité, la reproductibilité, la variabilité et l'effet des conditions expérimentales ont été évalués. La DWS pourrait être utilisée pour étudier l'effet de la température et de la congélation sur le spectre de DWS des tissus biologiques ou combinée à la rhéologie pour suivre l'évolution des spectres de DWS au cours d'un cisaillement / Diffusing Wave Spectroscopy (DWS) is a technique that allows to probe the internal dynamics of opaque media and concentrated at high frequencies. It has been used to determine the viscoelastic properties of these media. It has the advantage of being nondestructive, rapid and sensitive. This work aims to study soft biological materials by DWS. The first step is setting up of the experimental device. To evaluate the limits of the art, successive studies were conducted on materials of increasing complexity (a suspension, milk and a foam) tending to the structural complexity of biological tissues. Concerning the suspension and milk, two concentrated media, and mono-dispersed in which the particles are in Brownian motion, DWS allowed to measure with good precision their viscosity. The limits of DWS to evaluate the viscosity of the medium are achieved with the foam which the complex structure is similar to that of soft biological tissues. Finally, the renal cortex, the hepatic parenchyma and porcine brain were studied. The theory applied to previous media does not allow to calculate viscosity. But the DWS allowed us to follow their microstructure during dehydration and degeneration. For all these media, repeatability, reproducibility, variability and effect of experimental conditions were evaluated. The DWS could be used to study the effect of temperature and freezing on the DWS spectrum of biological tissues, or combined with rheology to monitor the evolution spectra DWS during shear

Page generated in 0.0304 seconds