• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 196
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 198
  • 45
  • 39
  • 33
  • 30
  • 25
  • 22
  • 20
  • 20
  • 20
  • 18
  • 16
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Alterações morfológicas nos vasos da íris de ratos normais e diabéticos aloxânicos

Pinto, Fábio Triglia [UNESP] January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2002Bitstream added on 2014-06-13T19:47:17Z : No. of bitstreams: 1 pinto_ft_me_botfm.pdf: 958150 bytes, checksum: 843d0330e855d190281854ed5ea3461d (MD5) / O objetivo do presente estudo foi avaliar a presença de alterações morfológicas nos vasos irianos de ratos normais e diabéticos aloxânicos. Material e Método: Foram utilizados 16 ratos da raça Wistar, divididos em 2 grupos experimentais: grupo controle (GC) e grupo diabético (GD). A indução do diabete foi feita por injeção endovenosa de Aloxana. Os animais foram acompanhados com avaliação clínica e exames laboratoriais durante todo o período experimental, tendo sido sacrificados em 2 momentos: M1(1 mês) e M2 (12 meses) após o início do seguimento. Estudou-se os vasos irianos sob microscopia óptica e eletrônica de transmissão. Resultados: A avaliação morfológica do GC mostrou que os ratos apresentaram espessamento da membrana basal nas células endoteliais e pericitos assim como aumento dos corpos densos principalmente no M2. Os animais do GD apresentaram alterações nas células endoteliais, pericitos , células musculares e fibroblastos perivasculares . Os pericitos, assim como as células musculares, estiveram mais alteradas que as células endoteliais. Todas as alterações foram mais freqüentes no M2, sendo mais importantes nos animais do GD. Conclusões: Os vasos da íris de ratos apresentam alterações decorrentes da senilidade. Alterações semelhantes ocorrem nos ratos diabéticos, que as apresentam com maior intensidade, principalmente quando a descompensação metabólica ocorre por tempo prolongado. Descritores: diabetes experimental, rato, íris, vasos, microscopia eletrônica de transmissão. / The objective of this study was to assess the presence of morphological changes in iris vessels of both normal and diabetic alloxanic rats. Material and Method: 16 Wistar rats have been used, divided into 2 experimental groups: Control Group (GC) and Diabetic Group (GD). The diabetes induction was made by Alloxan intravenous injection. The animals had been observed by clinical assessments and laboratory tests throughout the experimental period, having been slaughtered at 2 experimental moments: M1 – the animals were slaughtered one month after the experiment beginning, and M2 – the animals were slaughtered 12 months after the experiment beginning. At both moments, the iris vessels had been studied under both optical and electronical transmission microscopes. Results: The morphological assessment of the GC animals showed that, at M2, the rats presented dense bodies increasing and basal membrane thickening in endothelial cells, pericytes and muscles cells. GD animals presented changes in endothelial cells, pericytes and muscles cells beyond basal membrane thickening. Pericytes, as well as muscles cells, had more changes than endothelial cells. All changes were more frequent at M2, being more important in GD animals. Conclusions: The iris vessels of rats present changes relating to senility. Similar changes occur to diabetic rats, within wider intensity, mainly when metabolic disorder continues for a longer time. Describers: experimental diabetes, rat, iris, vessels, electronical transmission microscopy.
62

Implante de cimento de alfa-fosfato tricálcico de dupla pega munido de canais de interconexão em órbita de coelhos

Gomes Junior, Deusdete Conceição [UNESP] 18 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-18Bitstream added on 2014-06-13T19:30:07Z : No. of bitstreams: 1 gomesjunior_dc_me_jabo.pdf: 624070 bytes, checksum: a517292c6e1d8ca2eedd629c534840fb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Os implantes oculares são empregados após a remoção do bulbo do olho ou seu conteúdo, visando a manutenção do volume orbitário e a posterior colocação de prótese ocular. Estes são classificados como integráveis ou não integráveis, quando permitem ou não a infiltração de tecido fibrovascular do hospedeiro, respectivamente. Considerando a cirurgia protética como procedimento de relevância na oftalmologia veterinária e humana, buscou-se com a pesquisa avaliar macroscopicamente e por microscopia eletrônica de varredura as esferas do cimento de -fosfato tricálcico de dupla pega munido de canais de interconexão, assim como a integração do implante com o tecido orbital de coelhos, por meio de análise macroscópica e histopatológica. Doze animais compuseram o grupo experimental, sendo submetidos a enucleação do olho esquerdo e inserção do implante. Os períodos de avaliação foram 15, 45, 90 e 180 dias de pós-operatório, com exenteração da órbita de três animais, por período, para análise histopatológica. A microarquitetura das esferas caracterizou-se pela formação de colunas de cristais hexagonais e microporos medindo de 1,3-5,5 m e 0,5-5,6 m, respectivamente. Na avaliação histopatológica observou-se presença de fina cápsula ao redor do implante, de onde surgiram projeções fibrovasculares que o penetraram através dos canais de interconexão. Inicialmente foi constatada intensa reação inflamatória, com predomínio linfo-histiocitário, que diminuiu gradativamente ao longo do período de avaliação e foi ausente aos 180 dias. O implante mostrou-se biocompatível e integrável uma vez que os orifícios permitiram a penetração de tecido fibrovascular / Ocular implants are employed after the removal of the eye or its internal content, aiming at maintaining the volume of orbit and the subsequent placing of ocular prosthesis. These are classified as integrable or not integrable, when enable or not the tissue infiltration fibrovascular stroma of the host, respectively. Considering the prosthetic surgery procedure of veterinary and human relevance in ophthalmology, sought with the research evaluate macroscopically and by scanning electron microscopy spheres of double-setting -tricalcium phosphate cement provided with interconnection channels, as well as the integration of the implant to the tissue orbital of rabbits, through macroscopic and histopathological analysis. Twelve animals composed the experimental group, being subjected to enucleation of the left eye and implant insertion. The evaluation periods are 15, 45, 90 and 180 days postoperatively, orbital exenteration with three animals, per period, for histopathological analysis. The microarchitecture of the spheres characterized by the formation of columns of hexagonal crystals and micropores measuring 1,3-5,5 m and 0,5-5,6 m, respectively. The histopathological evaluation revealed the presence of thin capsule around the implant, where arose the beams penetrated through the channels of interconnection. Intense inflammatory reaction initially was established, with a predominance lymphohistiocytic which decreased gradually over the period of evaluation and was out to 180 days. The implant proved to be biocompatible and integrable since the holes allowed the tissue penetration fibrovascular stroma
63

Efeitos da instilação de morfina na inflamação ocular induzida experimentalmente em coelhos

Ortencio, Kethye Priscila [UNESP] 04 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-04Bitstream added on 2014-06-13T20:50:55Z : No. of bitstreams: 1 000735507.pdf: 1411225 bytes, checksum: 8fbfb73fa3d61839b1f7a315321a5d4b (MD5) / Avaliou-se o efeito da instilação local de morfina 1% sobre a expressão do fator de necrose tumoral alfa (TNF-alfa), da interleucina-1 beta (IL-1beta), da prostaglandina E2 (PGE2) e da mieloperoxidase (MPO) e a turbidez do humor aquoso (flaremetria a laser) em olhos de coelhos com uveíte induzida por injeção intravítrea de endotoxina. Empregou-se 30 leporinos da raça Nova Zelândia Branco, separados em 5 grupos (n=6), a saber : basal, grupo controle (GC), grupo morfina (GM), grupo naloxona (GN), grupo morfina-naloxona (GMN). Sob anestesia dissociativa, injetou-se 0,1 mL, contendo 0,2 μg de endotoxina (parede celular de Salmonella typhimurium), na câmara vítrea do olho direito de cada animal para a indução da uveíte experimental. Para a avaliação, realizou-se a flaremetria a “laser” antes da injeção intravítrea de endotoxina (basal), e às 10 e 20 horas da indução da uveítes, ocasião em que os olhos tratados foram enucleados para a quantificação do fator de necrose tumoral alfa (TNF-alfa), da interleucina-1 beta (IL-1beta), da mieloperoxidase (MPO) e da prostaglandina E2 (PGE2) por ELISA. Os dados foram analisados estatisticamente, quanto contagem de fótons no humor aquoso (flaremetria a “laser”), aplicando-se análise de variância não paramétrica de Friedman, seguida do “post hoc test” de Dunn, ao nível mínimo de significância de p>0,05 e quanto à quantificação das citocinas, utilizando-se Análise de Variância de via única, seguida pelo teste de Tukey, nas avaliações entre grupos. Considerou-se o nível mínimo de significância p<0,05. Observou-se, após a indução da uveíte, elevação significativa no nível TNF-alfa e IL-1beta, comparativamente aos olhos basais (p<0,05) em todos os tratamentos estudados (GC, GM, GN, GMN). A atividade da MPO apresentou uma elevação não significativa após a indução da uveíte. Os níveis dessas citocinas... / To evaluate the effects of instillation of morphine 1% on the expression of tumor necrosis factor alpha (TNF-alpha), interleukin-1 beta (IL-1beta), prostaglandin E2 (PGE2) and myeloperoxidase (MPO) and the turbidity of aqueous humor (laser flaremetry) in the eyes of rabbits with uveitis induced by intravitreal injection of endotoxin. Were used 30 New Zealand White rabbits, separated into 5 groups (n = 6), as follows: healthy control group (CG), morphine group (GM), naloxone group (GN), morphine-naloxone group (GMN). Under dissociative anesthesia it was injected 0.1 mL containing 0.2 mg of endotoxin (cell wall of Salmonella typhimurium) in the vitreous of the right eye of each animal to induce experimental uveitis. For the evaluation, it was used laser flarimetry before intravitreal injection of endotoxin (baseline) and at 10 and 20 hours after the induction of uveitis, at which time the treated eyes were enucleated for the quantification of tumor necrosis factor alpha (TNF-alpha), interleukin-1 beta (IL-1beta), mieloperoxidase (MPO) and prostaglandin E2 (PGE2) by ELISA. The data were treated statistically, the photon count in the aqueous humor (laser flarimetry), applying Friedman’s nonparametric two-way analyses of variance test, then the Dunn’s post hoc test, the minimum level of significance was p> 0.05 and for quantification of cytokines using ANOVA one-way followed by Tukey test in ratings between groups. Considered the minimum level of significance p <0.05. It was observed after induction of uveitis, significant increase in the level of TNF-alpha and IL-1beta compared to baseline eyes (p <0.05) in all treatments (GC, GM, GN, GMN). The MPO activity showed a nonsignificant increase after induction of uveitis. The levels of these cytokines between groups presented similar except in the quantification of PGE2, which showed significant variation between groups GM and GNM (p <0,05). Based ...
64

Ultra-sonografia pré-cirúrgica da lente e do segmento posterior de cães portadores de catarata

Rodrigues Junior, Emílio Fernandes [UNESP] 25 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-25Bitstream added on 2014-06-13T19:09:49Z : No. of bitstreams: 1 rodriguesjunior_ef_me_jabo.pdf: 359523 bytes, checksum: 2c23cc1e2be735e8fdf242ca84017e13 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A ultra-sonografia do segmento posterior do bulbo do olho é procedimento necessário para a avaliação de cães com catarata, que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Foram avaliados 30 cães (56 olhos), machos ou fêmeas, com idade entre 3 a 14 anos, portadores de diferentes tipos de catarata, em estágios variados de evolução. Realizou-se a ecografia nos modos A e B para o exame da lente e do segmento posterior. Clinicamente, diagnosticou-se catarata madura em 41 olhos (73,21%), catarata imatura em 14 olhos (25%) e catarata hipermatura em apenas um caso (1,78%). Verificou-se, ainda, catarata cortical anterior, posterior e nuclear em 12 olhos (21,42%), catarata cortical anterior, posterior, nuclear e capsular posterior em 23 olhos (41,07%), catarata cortical anterior, posterior e capsular posterior em um olho (1,78%), catarata cortical anterior e nuclear em um olho (1,78%), catarata cortical anterior, nuclear e capsular posterior em cinco olhos (8,92%) e catarata cortical anterior em sete dos olhos (12,5%). Diferentes alterações ultra-sonográficas foram observadas no segmento posterior em 26 dos 56 olhos avaliados (46,42%), incluindo alterações como degeneração vítrea (12 olhos, 21,42%), exsudato ou hemorragia (sete olhos, 12,5%), persistência de artéria hialóide (quatro olhos, 7,14%) e sub-luxação do cristalino (três olhos, 5,35%). A partir dos resultados obtidos, reitera-se a relevância em se realizar a ultra-sonografia em pacientes da espécie canina candidatos à facectomia, dado que alterações do segmento posterior do bulbo do olho são de difícil identificação, quando a lente encontra-se opacificada. / The ultrasound inspection of bulb posterior segment of eyes is a necessary procedure for the evaluation of dogs with cataracts, which will be submitted to the surgery extraction, since the ophthalmoscopy is not feasible when there is opacification of the lens, specially in mature cataracts. Thirty dogs were evaluated (56 eyes), males or females, from 3 to 14 years, affected with different types of cataracts in various developing stages. There was an ultrasound A and B in order to examine the lens and the posterior segment. The dogs were clinically diagnosed to the presence of cataract, demonstrating that 41 eyes (73.21%) was mature, 14 eyes (25%) imature and only one case (1.78%) hypermature. It was verified that 12 dogs eyes (21.42%) showed earlier cortical cataracts, posterior and nuclear, 23 eyes (41.07%) capsular earlier cortical cataracts, posterior and nuclear, one eye (1.78%) capsular earlier cortical cataracts and posterior capsular in cortical cataracts and nuclear up in one eye (1.78%), cortical cataracts earlier, nuclear and capsular in five eyes (8.92%) and cortical cataracts in seven previous eyes (12.5%). Changes in ultrasound evaluation were observed in the posterior segment in 26 of the 56 eyes evaluated (46.42%), including changes as vitreous degeneration 12 eyes, (21.42%), exudate or bleeding 7 eyes (12.5%), continuing artery hyaloid 4 eyes (7.14%) and sub dislocation of the lens 3 eyes (5.35%). From the results reaffirms the importance to take place in the ultrasound patients in the species canine candidates for extraction, since changes in the posterior segment of the bulb of the eyes are difficult to identify, when the lens is opacified.
65

Alterações clínicas, protéicas do humor aquoso, sorológicas e histopatológicas em olhos de cães (Canis familiaris) (Linnaeus, 1758), infectados experimentalmente, por via conjuntival, com Leishmania (Leishmania) chagasi (Cunha & Chagas, 1937)

Ribeiro, Andréa Gomes [UNESP] 28 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-28Bitstream added on 2014-06-13T20:30:39Z : No. of bitstreams: 1 ribeiro_ag_me_jabo.pdf: 446227 bytes, checksum: 4fe0c58b6076f1e60d23e8266e787eff (MD5) / Avaliaram-se as alterações oftálmicas, protéicas do humor aquoso, sorológicas e histopatológicas em cães infectados experimentalmente com Leishmania (Leishmania) chagasi por via conjuntival. Selecionaram-se dez cães saudáveis após exame clínico, prova sorológica de ELISA para Leishmania sp e microscopia de luz de esfregaços de medula óssea. Dois grupos de cães compuseram o estudo. O Grupo Inoculado (GI) foi constituído por sete animais, que receberam 150æL de uma solução de cultura de Leishmania (Leishmania) chagasi por via conjuntival, e o Grupo Controle (GC) por três animais, inoculados com solução salina fisiológica, pela mesma via. Os cães foram monitorados quanto às alterações oculares às 2, 4, 6, 12 e 24h após a instilação. Em seguida, diariamente por uma semana, e a partir daí, uma vez por semana, até que se completassem os 60 dias pós-infecção. Amostras de sangue e de humor aquoso de ambos os olhos e esfregaços de medula óssea foram coletados aos 60 dias, para sorologia, análise protéica e parasitologia, respectivamente. Todos os animais do GI mostraram sinais oculares unilaterais ou bilaterais, particularmente opacidades corneais. Não somente os resultados dos anticorpos anti-Leishmania sp no soro e no humor aquoso, como também a parasitologia, resultaram negativos. A histopatologia dos olhos de cães do grupo infectado por Leishmania revelou resposta inflamatória caracterizada por infiltração de macrófagos, linfócitos e células plasmáticas, notadamente na terceira pálpebra, na conjuntiva e na glândula lacrimal. Edema, congestão e perivasculite difusa envolvendo o trato uveal, igualmente foram observados. / The aim of this study was to evaluate the ocular signs protein of aqueous humour, serological and structural changes in the dogs' eyes infected experimentally by the conjunctival route of exposure with Leishmania (Leishmania) chagasi. A total of 10 healthy dogs were submitted to clinical examination, assayed by the ELISA test for anti- Leishmania sp antibodies and also microscopic examination of bone marrow smears. Two groups of dogs were studied. The first, Inoculated Group (IG) consisted of seven animal which one received a 150æL of Leishmania (Leishmania) chagasi suspension by the conjunctival route and the Control Group (CG) consisted of three animals inoculated by the saline physiological solution at the same route. The dogs were ophthalmology monitored at 2, 4, 6, 12 e 24 hours pos instilation. After this period, they were monitored once a day for one week and then, once a week until 60 days were complete. Blood samples, aqueous humor of both eyes and bone marrow smears were collected at 60 days for serology , protein of aqueous humour analyses and parasitological examination. All animals from IG showed unilateral or bilateral ocular signs, particularly corneal opacification. Not only the results of anti- Leishmania sp antibodies in sera and aqueous humor but also the parasitological examinations were negative. The histopathologic evaluation of eyes in the Leishmaniainfected dogs revealed inflammatory response characterized by macrophages infiltration, lymphocytes and plasma cells particularly on the third eyelid, the conjunctive tissue and lacrimal gland. Edema, congestion and a diffuse perivasculitis involving the uveal tract were also observed.
66

Estudo comparativo entre as esferas de silicone gelatinosas e rígidas em cavidade eviscerada de coelho /

Kanamura, Mayumi Shirota. January 2011 (has links)
Orientador: Silvana Artioli Schellini / Banca: Suzana Matayoshi / Banca: David Araf / Resumo: Apesar da existência de inúmeros tipos de implantes para reposição de volume em cavidades anoftálmicas, até o momento, nenhum deles pode ser considerado ideal, o que faz com que seja necessário continuar buscando novas soluções. Avaliar a biocompatibilidade de esferas de silicone gelatinosas e rígidas, quando colocadas em cavidades evisceradas de coelhos, comparando-as. Estudo prospectivo e experimental, no qual foram utilizados 30 coelhos albinos, espécie Orictolagus cuniculus, submetidos à cirurgia de evisceração do olho direito, sendo feita a colocação de esferas de silicone gelatinosas ou rígidas na cavidade escleral. Os animais foram sacrificados sete, 30 e 90 dias após a colocação das esferas. Os parâmetros avaliados foram: avaliação clínica diária, ultrassonografia da cavidade eviscerada 15 dias após o procedimento, análise histológica do conteúdo orbitário sete, 30 e 90 dias após a cirurgia, com análise morfométrica da pseudocápsula que se formou ao redor das esferas. Os resultados obtidos foram submetidos à avaliação estatística para comparação dos resultados entre e dentro dos grupos experimentais. Durante o seguimento, ocorreram três extrusões de esferas, duas das quais pertencentes ao grupo das esferas rígidas e uma, do grupo das esferas gelatinosas. O exame ultrassonográfico mostrou ausência de coleções ou processo inflamatório ao redor das esferas e boa integração das mesmas com os tecidos orbitários. Ao exame histológico observou-se semelhança de resposta tecidual com ambas as esferas. O exame morfométrico apontou para superioridade das esferas gelatinosas no tocante a espessura da pseudocápsula, que foi menos espessa, principalmente na avaliação feita no setor posterior da cavidade escleral. Todos os parâmetros estudados mostraram que as esferas de silicone... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Despite the existence of many types of implants for volume replacement in anophthalmic sockets, so far, none can be considered ideal implant, which makes it necessary to continue searching for new solutions. To evaluate the biocompatibility of soft and rigid silicone spheres placed in scleral cavities of eviscerated rabbits, comparing them. Prospctive and experimental study using 30 rabbits, specie Orictolagus cuniculus, underwent evisceration surgery of the right eye and replacement of orbital volume with spheres composed by gelatinous (soft) or rigid silicone. The animals were sacrificed seven, 30 and 90 days after surgery. The studies parameters were: daily clinical assessment, ultrasound of the orbit 15 days after the procedure, histological analysis of the orbital contents seven, 30 and 90 days after surgery and morphometric evaluation in the pseudocapsule in all the animals. Statistical analysis for comparison between and within groups was done. During follow-up occurred three spheres extrusions, two of which belonging to the group of rigid spheres and one from gelatinous sphere group. Ultrasound examination showed no inflammation or collections around spheres and good integration with the orbital tissues. The histological evaluation proved both materials had similar response and the morphometric evaluation showed thinner pseudocapsule formation around the gelatinous sphere, mainly in the posterior scleral region. All the parameters evaluated showed both spheres had good tecidual integration to the orbital tissue in rabbit eviscerated eyes. Therefore, gelatinous silicone sphere induced thinner psedudocapsule formation. The authors agree the gelatinous silicone spheres might be helpful to be used... (Complete abstract click electronic access below) / Mestre
67

Mensurações do bulbo ocular e cálculo do poder dióptrico da lente intraocular em miniporcos brasileiros /

Barros, Rodrigo. January 2015 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Banca: José Joaquim Titton Ranzani / Banca: Antônio Carlos Lottelli Rodrigues / Resumo: Este trabalho teve como objetivo determinar o poder dióptrico da lente intraocular (LIO) de miniporcos brasileiro e as dimensões do bulbo do olho. Foram utilizados 17 animais (34 olhos) clinicamente sadios, adultos, machos e fêmeas com peso médio de 70 kg. Em todos os olhos, foram realizadas a ultrassonografia modo A, ceratometria e a medida da distância limbo a limbo; variáveis para o cálculo do poder dióptrico da lente intraocular. Este foi obtido utilizando-se diferentes fórmulas e o software Holladay IOL Consultant®. Foram comparadas, adicionalmente, as mensurações oculares quanto ao sexo, lateralidade do olho e as diferentes fórmulas utilizadas (Haigis, Hoffer Q, SRK/T, Holladay I e Holladay II). Na comparação entre o sexo e lateralidade do olho, não houve diferença nas variáveis biométricas e poder da lente intraocular. A aplicação das fórmulas empregadas (Haigis, Holladay II, Holladay I, SRK/T e Hoffer Q) possibilita o cálculo do poder da lente intraocular nesta espécie, e o valor observado variou entre 39,58±2,15 e 46,6±2,81 dioptrias Os miniporcos desempenham importante e crescente papel como modelo experimental para a prática e estudos de procedimento oftalmológico, especialmente relacionados ao seu menor porte e facilidade no manejo de experimentos de longa duração / Abstract: The aim of this study is to determine the refractive power of intraocular lens (IOL) of Brazilian minipigs and the dimensions of the eyeball. Total of 17 animals (34 eyes) healthy, adult, males and females, with average weight of 70kg were used. For every eye, A-mode ultrasound, keratometry and the measure of limbo-to-limbo distance were conducted; all of them variables for calculating the refractive power of the IOL. That value was obtained using different formulas and Holladay IOL Consultant® Software. Were additionally compared the ocular measurements for sex, laterality of the eye and the different formulas used in this study (Haigis, Hoffer Q, SRK / T, Holladay I and Holladay II). In the comparison between sex and laterality of the eye, there is no difference in biometric variables and power of the IOL. The application of the employed formulas (Haigis, Holladay II, Hollada I, SRK / T and Hoffer Q) allows the IOL power calculation of this specie, and the observed value ranged between 39,58±2,15 and 46,60±2,81 diopters. The minipig has an important and growing role as an experimental model for the study and practice of ophthalmic procedure, specially related to their smaller size and easily management in long term experiments / Mestre
68

Micropartículas lipídicas sólidas obtidas por spray drying para liberação intraocular de ibuprofeno /

Pere, Cristiane Patricia Pissinato. January 2014 (has links)
Orientador: Anselmo Gomes de Oliveira / Banca: Clovis Augusto Ribeiro / Banca: Leila Aparecida Chiavacci / Resumo: Doenças vítreoretinianas são doenças graves do segmento posterior do olho caracterizadas por manifestações inflamatórias importantes e que se não tratadas adequadamente evoluem para perda irreversível da visão. Embora grandes avanços tenham ocorrido nas áreas médicas e tecnológicas, o tratamento de doenças que acometem o segmento posterior do olho continua sendo um desafio, em virtude das barreiras anatômicas e fisiológicas desse órgão que dificultam a entrada de substâncias exógenas. Uma alternativa é a administração local de fármacos veiculados em sistemas de liberação prolongada, capazes de prolongar o tempo de liberação do fármaco dentro da faixa terapêutica, reduzindo o número de administrações requeridas e proporcionando maior conforto e segurança ao paciente. O objetivo deste trabalho foi o desenvolvimento e a caracterização de Micropartículas Lipídicas Sólidas contendo ibuprofeno obtidas por spray dryer para potencial aplicação intraocular. MLS de fosfatidilcolina de soja hidrogenada modificadas por monoestearato de glicerila ou álcool estearílico, adicionadas de 15 ou 30% de ibuprofeno foram obtidas. De acordo com a microscopia eletrônica de varredura, as MLS apresentaram morfologias predominantemente esféricas e homogêneas. As análises de infravermelho, calorimetria exploratória diferencial e difração de raios X sugerem que o fármaco esteja disperso ou dissolvido na matriz da MLS. Tais resultados também mostraram que o método foi capaz de reduzir a cristalinidade do fármaco e dos demais componentes da micropartícula, favorecendo a eficiência de encapsulação e a subsequente difusão do fármaco no estudo de liberação. O estudo de liberação mostrou uma saída rápida de fármaco das MLS nos tempos iniciais, seguido por uma liberação mais lenta, podendo ser interessante tanto em tratamentos de pós-operatórios como em tratamentos de outras doenças vitreoretinianas. / Abstract: Vitreoretinal diseases are serious disease of the posterior segment of the eye. They are characterized by important inflammatory manifestations and if it is not treated properly they develop into irreversive blindness. Although major advances have occurred in the medical and tecnhological fiels, the treatment of deseases that affecting the posterior segment of the eye remains a challenge, because of the anatomical and physiological barrier's eyes that hinder the entrance of exogenous substances. An alternative is the local drug delivery in drug delivery systems, whom are able to prolong release of the drug within the therapeutic range systems, reducing the number of administrations and providing more confort and safety for patient. The aim of this work was the development and characterization ibuprofen loaded solid lipid microparticles obtained by spray drying method for a potential intraocular application. Hydrogenated soy phosphatidylcholine SLM modified by glyceryl monostearate or stearyl alcohol, added 15 to 30% of ibuprofen were obtained. According to scanning electron microscopy, the MLS showed mostly spherical and homogeneous morphologies. The infrared analysis, differential scanning calorimetry and x-ray diffraction suggest that the drug is solubilized in the MLS array. These results also showed that the method was able to reduce the crystallinity of the drug and other components of the microparticle, favoring the encapsulation efficiency and the subsequent diffusion of the drug release study. The release study showed a busrt release followed by a sustained release, that may be useful not only in the treatment of postoperative cataract surgery and in the treatment of diseases vitreoretinianas itself. / Mestre
69

Ultrassonografia do bulbo do olho de cães, com diferentes conformações cranianas /

Toni, Maria Carolina. January 2011 (has links)
Orientador: Júlio Carlos Canola / Banca: José Luiz Laus / Banca: Fabrício Singaretti de Oliveira / Resumo: Com o presente estudo pretendeu-se conhecer os valores médios para as estruturas intraoculares e compará-los entre cães com diferentes conformações cranianas por meio da ultrassonografia ocular com transdutor de 20 MHz. Foram selecionados 30 cães, adultos, peso corpóreo até 10 kg, machos ou fêmeas, hígidos, atendidos no Hospital Veterinário "Governador Laudo Natel" - Faculdade de Ciências Agrárias e Veterinárias - UNESP - Câmpus de Jaboticabal. Os cães foram distribuidos em três grupos: G1 - 10 braquicefálicos, G2 - 10 mesocefálicos e G3 - 10 dolicocefálicos. Na análise estatística realizada pelo teste t Student com nível de significância de 5%, não houve diferença entre os olhos direito e esquerdo dos cães do mesmo grupo (p > 0,05). Valores médios e desvios padrão foram obtidos para profundidade da câmara anterior (D1), espessura da lente (D2), profundidade da câmara vítrea (D3) e comprimento axial do bulbo do olho (D4) nos três grupos. G1: D1 2,92mm (± 0,37), D2 7,03mm (± 0,61), D3 9,48mm (± 0,74) e D4 19,43mm (± 0,60). G2: D1 3,08mm (± 0,67), D2 7,02mm (± 0,87), D3 8,76mm (± 1,23) e D4 18,86mm (± 1,45). G3: D1 3,07mm (± 0,65), D2 7mm (± 0,81), D3 9,75mm (± 0,98) e D4 19,82mm (± 0,95). Para comparação dos valores médios de D1, D2, D3 e D4 entre os grupos, foi utilizado o teste de Tukey, com nível de significância de 5%. Na análise de D3, foi observada diferença (p < 0,05) na comparação entre G2 e G3. Na análise de D4, foi observada diferença (p < 0,05) na comparação entre G2 e G3 / Abstract: The present study aimed to know the average values of the intraocular structures and compare among different skulls' conformations in dogs using ocular ultrasonography with 20 MHz probe. They were selected 30 healthy adult dogs, body weight 10 kg, male or female, assisted at "Governador Laudo Natel" Veterinary Teaching Hospital - Faculdade de Ciências Agrárias e Veterinárias - UNESP - Campus of Jaboticabal. Animals were divided into three groups: G1 - 10 brachycephalic dogs, G2 - 10 mesocephalic dogs and G3 - 10 dolicocephalic dogs. The Student t test at 5% significance level was used to compare difference between right and left eyes of the dogs in the same group and no difference was found (p > 0.05). Mean and standard deviations were obtained for anterior chamber depth (D1), lens thickness (D2), vitreous chamber depth (D3) and axial length of the eye globe (D4) in the three groups. G1: D1 2.92mm (± 0.37), D2 7.03mm (± 0.61), D3 9.48mm (± 0.74) and D4 19.43mm (± 0.60). G2: D1 3.08mm (± 0.67), D2 7.02mm (± 0.87), D3 8.76mm (± 1.23) and D4 18.86mm (± 1.45). G3: D1 3.07mm (± 0.65), D2 7mm (± 0.81), D3 9.75mm (± 0.98) and D4 19.82mm (± 0.95). The Tukey test at 5% significance level was used to compare the average of D1, D2, D3 and D4 among groups. Differences between G2 and G3 were found (p <0.05) when comparing D3 and D4 / Mestre
70

Implante de cimento de alfa-fosfato tricálcico de dupla pega munido de canais de interconexão em órbita de coelhos /

Gomes Junior, Deusdete Conceição. January 2012 (has links)
Orientador: Carlos Roberto Daleck / Coorientador: João Moreira da Costa Neto / Coorientador: Arianne Pontes Oriá / Banca: Andrigo Barboza de Nardi / Banca: Duvaldo Eurides / Resumo: Os implantes oculares são empregados após a remoção do bulbo do olho ou seu conteúdo, visando a manutenção do volume orbitário e a posterior colocação de prótese ocular. Estes são classificados como integráveis ou não integráveis, quando permitem ou não a infiltração de tecido fibrovascular do hospedeiro, respectivamente. Considerando a cirurgia protética como procedimento de relevância na oftalmologia veterinária e humana, buscou-se com a pesquisa avaliar macroscopicamente e por microscopia eletrônica de varredura as esferas do cimento de -fosfato tricálcico de dupla pega munido de canais de interconexão, assim como a integração do implante com o tecido orbital de coelhos, por meio de análise macroscópica e histopatológica. Doze animais compuseram o grupo experimental, sendo submetidos a enucleação do olho esquerdo e inserção do implante. Os períodos de avaliação foram 15, 45, 90 e 180 dias de pós-operatório, com exenteração da órbita de três animais, por período, para análise histopatológica. A microarquitetura das esferas caracterizou-se pela formação de colunas de cristais hexagonais e microporos medindo de 1,3-5,5 m e 0,5-5,6 m, respectivamente. Na avaliação histopatológica observou-se presença de fina cápsula ao redor do implante, de onde surgiram projeções fibrovasculares que o penetraram através dos canais de interconexão. Inicialmente foi constatada intensa reação inflamatória, com predomínio linfo-histiocitário, que diminuiu gradativamente ao longo do período de avaliação e foi ausente aos 180 dias. O implante mostrou-se biocompatível e integrável uma vez que os orifícios permitiram a penetração de tecido fibrovascular / Abstract: Ocular implants are employed after the removal of the eye or its internal content, aiming at maintaining the volume of orbit and the subsequent placing of ocular prosthesis. These are classified as integrable or not integrable, when enable or not the tissue infiltration fibrovascular stroma of the host, respectively. Considering the prosthetic surgery procedure of veterinary and human relevance in ophthalmology, sought with the research evaluate macroscopically and by scanning electron microscopy spheres of double-setting -tricalcium phosphate cement provided with interconnection channels, as well as the integration of the implant to the tissue orbital of rabbits, through macroscopic and histopathological analysis. Twelve animals composed the experimental group, being subjected to enucleation of the left eye and implant insertion. The evaluation periods are 15, 45, 90 and 180 days postoperatively, orbital exenteration with three animals, per period, for histopathological analysis. The microarchitecture of the spheres characterized by the formation of columns of hexagonal crystals and micropores measuring 1,3-5,5 m and 0,5-5,6 m, respectively. The histopathological evaluation revealed the presence of thin capsule around the implant, where arose the beams penetrated through the channels of interconnection. Intense inflammatory reaction initially was established, with a predominance lymphohistiocytic which decreased gradually over the period of evaluation and was out to 180 days. The implant proved to be biocompatible and integrable since the holes allowed the tissue penetration fibrovascular stroma / Mestre

Page generated in 0.0303 seconds