• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 23
  • 12
  • 12
  • 12
  • 6
  • 1
  • Tagged with
  • 112
  • 112
  • 42
  • 31
  • 30
  • 26
  • 25
  • 24
  • 21
  • 20
  • 20
  • 19
  • 18
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Gestión eficiente de los convertidores de potencia conectados al bus DC de una Microrred híbrida de generación distribuida

Salas Puente, Robert Antonio 22 March 2019 (has links)
Tesis por compendio / [ES] Dos aspectos críticos en la operación de una microrred son las estrategias de control y gestión de potencia implementadas, las cuales son esenciales para proporcionar su buen funcionamiento. La aplicación adecuada de dichas estrategias permite compensar los desequilibrios de potencia causados por la discontinuidad de la generación y de la demanda de energía en las microrredes. En este sentido, el objetivo global de estas estrategias de gestión es equilibrar adecuadamente el flujo de potencia en la microrred, mediante la aplicación de diferentes algoritmos que permiten cumplir con los criterios de estabilidad, protección, balance de potencia, transiciones, sincronización con la red y gestión adecuada de la microrred. En el caso de microrredes de pequeña escala de potencia con bajo número de generadores y sistemas de almacenamiento distribuidos, las estrategias de control centralizado ofrecen un alto nivel de flexibilidad para lograr funcionalidades avanzadas en la microrred y una adecuada distribución de la potencia entre los convertidores que la conforman. Esta tesis se ha enmarcado en el contexto de algoritmos de gestión centralizada de potencia de una microrred de generación distribuida en modo conectado a red. Los algoritmos presentados se pueden aplicar a los convertidores de potencia conectados al bus DC de una microrred AC/DC híbrida o en una microrred de DC, donde el despacho de potencia es observado y gestionado por un controlador central. Este último adquiere datos del sistema mediante una infraestructura de comunicaciones y estima la potencia que gestionará cada uno de los convertidores de potencia, sistemas de almacenamiento y cargas en funcionamiento. En este estudio se muestra la validación experimental de las estrategias de gestión aplicadas en la microrred desde el enfoque del comportamiento de los convertidores de potencia, de las baterías y las cargas ante dicha gestión. Se verifica la estabilidad de la microrred sometiendo a los convertidores a diferentes escenarios de funcionamiento. Estos escenarios pueden ser fluctuaciones en la irradiación, la demanda, el estado de carga de las baterías, los límites máximos de exportación/importación de potencia desde/hacia la microrred hacia/desde la red principal y de la tarifa eléctrica. Adicionalmente, se propone un sistema de almacenamiento de energía en baterías encargado de mantener el equilibrio de potencia en el bus de DC de la microrred que permite aprovechar las fuentes de generación renovables presentes en la microrred y maximizar el tiempo de servicio de las baterías mediante la aplicación de un algoritmo de carga de las baterías. Este último se ajusta al procedimiento de carga especificado por el fabricante, estableciendo las tasas de carga en función de los escenarios en que la microrred se encuentre. El procedimiento de carga en las baterías es fundamental para garantizar las condiciones adecuadas de operación de las mismas, ya que toman en consideración los parámetros establecidos por el fabricante, como son: tasas de carga/descarga, tensión máxima de carga, temperaturas de operación, etc. / [CA] Dos dels aspectes crítics en l'operació d'una micro-xarxa són les estratègies de control i gestió de potència implementades, les quals són essencials per proporcionar el seu bon funcionament. L'aplicació adequada de dites estratègies permet compensar els desequilibris de potència causats per la discontinuïtat de la generació i demanda d'energia en les micro-xarxes. En aquest sentit, l'objectiu global de les nomenades estratègies de gestió és equilibrar adequadament el flux de potència en la micro-xarxa mitjançant l'aplicació de diferents algoritmes que permeten complir amb els criteris d'estabilitat, protecció, balanç de potència, transicions, sincronització amb la xarxa i gestió adequada de la micro-xarxa. En el cas de micro-xarxes de potència a petita escala i amb baix nombre de generadors i sistemes d'emmagatzematge distribuïts, les estratègies de control centralitzades ofereixen un alt nivell de flexibilitat per aconseguir funcionalitats avançades en la micro-xarxa i una adequada distribució de la potència entre els convertidors que la conformen. Aquesta tesi s'ha emmarcat al context d'algoritmes de gestió centralitzada de potència d'una micro-xarxa de generació distribuïda en mode de connexió a xarxa. Els algoritmes presentats es poden aplicar als convertidors de potència connectats al bus DC d'una micro-xarxa AC/DC hibrida o en una micro-xarxa de DC, on el despatx de potència és observat i gestionat per un controlador central. Aquest últim adquireix dades del sistema mitjançant una infraestructura de comunicacions i estima la potència que gestionarà cadascun dels convertidors de potència, sistemes d'emmagatzematge i càrregues en funcionament. En aquest estudi es mostren la validació experimental de les estratègies de gestió aplicades en la micro-xarxa des d'un enfocament dels convertidors de potència, de les bateries i les càrregues davant d'aquesta gestió. Es verifica l'estabilitat de la micro-xarxa exposant als convertidors a diferents escenaris de funcionament. Aquest escenaris poden ser fluctuants en la irradiació, la demanda, l'estat de càrrega de les bateries, els límits màxims d'exportació/importació de potència des de/cap a la micro-xarxa cap a/des de la xarxa principal i de la tarifa elèctrica. Addicionalment, es proposa un sistema d'emmagatzematge d'energia en bateries encarregats de mantindre l'equilibri de potència al bus DC de la micro-xarxa i que permet aprofitar les fonts de generació renovables presents en la micro-xarxa i maximitzar el temps de servei de les bateries mitjançant l'aplicació d'un algoritme de càrrega de bateries. Aquest últim s'ajusta al procediment de càrrega especificat pel fabricant, establint les taxes de càrrega en funció dels escenaris en que la micro-xarxa es trobe. El procediment de càrrega a les bateries es fonamental per garantir les condicions adequades d'operació de les mateixes, ja que prenen en consideració els paràmetres establerts pel fabricant, com ara són: taxes de càrrega/descàrrega, tensió màxima de càrrega, temperatures d'operació, etc. / [EN] Two critical aspects in microgrids operation are the control and power management strategies, which are essential for their efficient operation. The adequate application of these strategies allows compensating the power imbalance caused by the discontinuity in the energy generation or changes in the power demand of the microgrid. In this sense, the overall objective of these power management strategies is to keep the power balance between the generation and the demand in the microgrid through the application of different algorithms that fulfill the criteria of stability, protection, smooth transitions and synchronization with the main grid. In the case of small-scale microgrids with a low number of distributed generators and energy storage systems, the centralized control strategies offer a higher level of flexibility to achieve advanced features in the microgrid and for the suitable power sharing between the converters that compose it. This thesis has been focused on centralized power management algorithms of a microgrid working in grid connected mode. These algorithms can be applied to the power converters connected to the DC bus of both hybrid AC/DC and DC microgrids, where the power dispatch is controlled by a central controller which acquires system data through a communication infrastructure and sets the power to be managed by each of the converters under operation. In this thesis, the experimental validation of the power management strategies of the microgrid is presented, from the point of view of the behavior of the power converters, batteries and loads. It is provided with a realistic evaluation under different microgrid operation scenarios. These scenarios were sudden changes of the irradiation, load, state of charge, the maximum power to be exported/imported from/to the microgrid to/from the grid, and the electricity tariff. Additionally, it is proposed a battery energy storage system that keeps the power balance at the DC bus of the microgrid, taking advantage from the renewable energy sources and adjusting the battery energy storage through a suitable charging procedure specified by the manufacturer. The proposed procedure changes the charging parameters of the batteries depending on the microgrid states. Its goal is to extend the service time of batteries and to allow proper energy management in the system. / Salas Puente, RA. (2019). Gestión eficiente de los convertidores de potencia conectados al bus DC de una Microrred híbrida de generación distribuida [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/118658 / Compendio
102

Διερεύνηση της λειτουργίας και διάγνωση σφαλμάτων ηλεκτρονικού μετατροπέα ισχύος τοπολογίας μήτρας και εφαρμογή σε ηλεκτροκινητήριο σύστημα με ασύγχρονη μηχανή / Investigation of matrix converters operation, diagnosis of faults in matrix topology and application of matrix converter to induction motor drive systems

Ποταμιάνος, Παναγιώτης 08 January 2014 (has links)
Η διατριβή αυτή επικεντρώθηκε στη διερεύνηση της λειτουργίας των ηλεκτρονικών μετατροπέων ισχύος τοπολογίας μήτρας (matrix converters) και, ειδικότερα, των άμεσων μετατροπέων τοπολογίας μήτρας. Ο άμεσος μετατροπέας τοπολογίας μήτρας με τρία σκέλη αποτελείται από 18 τρανζίστορ ισχύος και 18 διόδους ισχύος και χρησιμοποιείται για τη μετατροπή μίας τριφασικής εναλλασσόμενης τάσης σε τριφασική εναλλασσόμενη τάση στην έξοδό του, με δυνατότητες ρύθμισης του πλάτους και της συχνότητας της τάσης εξόδου, διαμόρφωσης του ρεύματος εισόδου, ρύθμισης του συντελεστή ισχύος στην είσοδο και αμφίδρομης ροής ισχύος. Η μετατροπή αυτή γίνεται σε ένα στάδιο, χωρίς ενδιάμεσο στάδιο συνεχούς τάσης (ή συνεχούς ρεύματος), με αποτέλεσμα την αποφυγή χρήσης πυκνωτών μεγάλης χωρητικότητας και πηνίων μεγάλης επαγωγιμότητας. Οι μετατροπείς τοπολογίας μήτρας χαρακτηρίζονται από υψηλούς βαθμούς απόδοσης, υψηλές πυκνότητες ισχύος και πολύ μεγάλους λόγους ισχύος προς μάζα, ενώ το αρμονικό περιεχόμενο της τάσης εξόδου και του ρεύματος εισόδου αυτών είναι μικρό. Η πολυπλοκότητα αυτών των μετατροπέων είναι υψηλή και η δυσκολία υλοποίησής τους σημαντική. Η διερεύνηση των άμεσων μετατροπέων τοπολογίας μήτρας στα πλαίσια της παρούσας διατριβής εστιάστηκε κυρίως στην ανάπτυξη μεθόδων διάγνωσης σφαλμάτων ανοικτοκυκλώματος που συμβαίνουν στο μετατροπέα, καθώς και στην ανάπτυξη μεθόδων παλμοδότησης αυτών που βασίζονται στη χρήση φορέα για την κανονική και επανορθωτική τους λειτουργία. Η διατριβή αυτή περιλαμβάνει οκτώ κεφάλαια, το περιεχόμενο των οποίων περιγράφεται ακολούθως. Στο Κεφάλαιο 1 γίνεται μία εισαγωγή στους στόχους και τη διάρθρωση της παρούσας διατριβής. Στο Κεφάλαιο 2 γίνεται μία εισαγωγή στους ηλεκτρονικούς μετατροπείς ισχύος εναλλασσόμενης τάσης σε εναλλασσόμενη τάση μεταβλητής συχνότητας και πλάτους. Στο κεφάλαιο αυτό περιλαμβάνεται η περιγραφή και η σύγκριση διαφόρων μετατροπέων τοπολογίας μήτρας, καθώς και η περιγραφή των συμβατικών μετατροπέων που χρησιμοποιούνται για την ίδια μετατροπή τάσης και η σύγκριση τους με τις δύο βασικότερες παραλλαγές των μετατροπέων τοπολογίας μήτρας. Στο Κεφάλαιο 3 περιγράφονται οι μέθοδοι που εφαρμόζονται για τον έλεγχο του άμεσου μετατροπέα τοπολογίας μήτρας. Συγκεκριμένα, περιγράφονται και συγκρίνονται διάφορες μέθοδοι παλμοδότησης που χρησιμοποιούνται σε αυτούς τους μετατροπείς, καθώς και οι βασικότερες μέθοδοι μετάβασης του ρεύματος. Στο κεφάλαιο αυτό περιλαμβάνεται η περιγραφή μίας νέας μεθόδου παλμοδότησης με τη χρήση φορέα που αναπτύχθηκε στα πλαίσια της παρούσας διατριβής και οδηγεί σε μειωμένες διακοπτικές απώλειες για χρήση στην περίπτωση που ο επιθυμητός λόγος μεταφοράς τάσης είναι μικρότερος ή ίσος του 50%. Στο Κεφάλαιο 4 περιγράφονται ο άμεσος μετατροπέας τοπολογίας μήτρας που σχεδιάσθηκε και κατασκευάσθηκε στο Εργαστήριο Ηλεκτρομηχανικής Μετατροπής Ενέργειας και τα υπόλοιπα στοιχεία της πειραματικής διάταξης. Επιπρόσθετα, παρατίθενται ορισμένα αποτελέσματα πειραματικών δοκιμών που αφορούν τη λειτουργία επιμέρους τμημάτων του μετατροπέα. Στο Κεφάλαιο 5, αρχικώς, γίνεται μία σύντομη περιγραφή του μοντέλου του υπό μελέτη συστήματος στο περιβάλλον του λογισμικού Matlab/Simulink, παρατίθενται οι τιμές διαφόρων παραμέτρων αυτού και παρουσιάζονται και σχολιάζονται αποτελέσματα προσομοιώσεων της κανονικής λειτουργίας του άμεσου μετατροπέα τοπολογίας μήτρας. Επιπρόσθετα, περιγράφεται μία μέθοδος διανυσματικού ελέγχου της ταχύτητας περιστροφής μίας ασύγχρονης μηχανής τροφοδοτούμενης από άμεσο μετατροπέα τοπολογίας μήτρας και παρουσιάζονται αποτελέσματα προσομοιώσεων της λειτουργίας ενός τέτοιου συστήματος. Τέλος, στο κεφάλαιο αυτό παρουσιάζονται και σχολιάζονται αποτελέσματα πειραματικών δοκιμών της κανονικής λειτουργίας του άμεσου μετατροπέα τοπολογίας μήτρας. Στο Κεφάλαιο 6 εξετάζονται τα πιθανά σφάλματα στον άμεσο μετατροπέα τοπολογίας μήτρας και παρουσιάζονται αναλυτικά οι μέθοδοι διάγνωσης σφαλμάτων ανοικτοκυκλώματος και εντοπισμού ανοικτοκυκλωμένων τρανζίστορ σε αυτόν το μετατροπέα που αναπτύχθηκαν στα πλαίσια αυτής της διατριβής. Περιγράφονται, επίσης, ορισμένες τεχνικές επεξεργασίας σήματος και στοιχεία της θεωρίας των ασαφών έμπειρων συστημάτων, τα οποία χρησιμοποιούνται στις μεθόδους διάγνωσης που προτάθηκαν στα πλαίσια αυτής της διατριβής. Στο Κεφάλαιο 7 περιγράφονται τοπολογίες και μέθοδοι παλμοδότησης για την επανορθωτική λειτουργία κινητηρίων συστημάτων με άμεσους μετατροπείς τοπολογίας μήτρας μετά την εμφάνιση σφαλμάτων στο μετατροπέα. Στο κεφάλαιο αυτό περιλαμβάνεται η περιγραφή δύο μεθόδων παλμοδότησης με χρήση φορέα για την επανορθωτική λειτουργία του άμεσου μετατροπέα τοπολογίας μήτρας μετά από ένα σφάλμα ανοικτοκυκλώματος, μία για το μετατροπέα με πρόσθετο (τέταρτο) σκέλος και μία για το μετατροπέα χωρίς πρόσθετα στοιχεία, που αναπτύχθηκαν στα πλαίσια αυτής της διατριβής. Τέλος, στο Κεφάλαιο 8 επισημαίνεται η συμβολή της παρούσας διδακτορικής διατριβής στην έρευνα σχετικά με τους Μ.Τ.Μ., ανακεφαλαιώνονται τα αποτελέσματα αυτής και αναφέρονται σημεία που μπορούν να αποτελέσουν αντικείμενο επιστημονικής έρευνας στο μέλλον. / This thesis was focused on the research in the matrix converters domain and, particularly, in direct matrix converters. The 3-leg direct matrix converter consists of 18 power transistors and 18 power diodes and is used for the conversion of a three-phase AC voltage to a three-phase AC voltage of variable amplitude and variable frequency. This topology is also capable of modulating the input current and adjusting the input power factor, whereas bidirectional power flow is allowed. This conversion is achieved in one stage with the direct connection of the input phases with the output phases, without using an intermediate DC link stage, resulting in elimination of the use of large capacitors and large inductors. The use of the matrix topology in power converters results in high efficiency, high power density and very high power-to-mass ratio, whereas the harmonic distortion of the output voltage and the input current is low. The complexity of the matrix converters is high resulting in significant implementation effort. In this thesis, the research in direct matrix converters was focused mainly on the development of diagnosis methods for open-circuit faults that arise in the matrix topology, as well as the development of carrier-based modulation methods for the normal and remedial operation of these converters. This thesis contains eight chapters, the content of which is described below. In Chapter 1 an introduction and a brief description of the aims and the structure of this thesis are provided. In Chapter 2 an introduction to the AC-AC power converters used for the modulation of an output voltage of variable amplitude and variable frequency is provided. A description and a comparison of various matrix converter topologies, a description of the conventional topologies used for the same voltage conversion and a comparison of the latter with the two most popular matrix topologies are included in this chapter. In Chapter 3 the methods required for the control of the direct matrix converter are presented. In detail, various modulation methods are described and compared and the most significant commutation methods are presented. In this chapter a novel carrier-based modulation method that was proposed in this work is also described which results in reduced switching losses for use in cases that the required voltage transfer ratio is up to 50%. In Chapter 4 the direct matrix converter that was designed and constructed in this work is presented and other parts of the experimental setup are described. Additionally, some experimental results related to the operation of matrix converter parts are provided. In Chapter 5 a brief description of the studied system’s model that was created using the Matlab/Simulink software is provided, the value of various parameters of this model is given and simulation results of the normal (healthy) operation of the matrix converter are presented and commented. Additionally, a vector control method for the speed control of an induction machine fed by a matrix converter is described and simulation results of its operation are demonstrated. Finally, experimental results of the normal operation of the matrix converter are presented and commented. In Chapter 6 the possible faults in direct matrix converters are studied and the methods to detect open-circuit faults and the open-circuited transistors localization method that were developed in this work are presented. Additionally, a description of signal processing methods and the basic theory of fuzzy inference systems, which are used by the proposed diagnosis methods, are included. In Chapter 7 topologies and modulation methods used for the remedial operation of the direct matrix converter after the occurrence of a fault are presented. In this chapter two carrier-based modulation methods for the remedial operation of the direct matrix converter after an open-circuit fault occurrence that were developed in this work are also described, one for the case of using a redundant (fourth) leg and one for the case of not using any redundant switches. In Chapter 8 the contribution of this thesis to the research in the matrix converters domain is highlighted, its additional results are noted and subjects of possible future work are provided.
103

Conception et réalisation d'un convertisseur multicellulaire DC/DC isolé pour application aéronautique / Design and development of an isolated multicell DC/DC power converter for aeronautical applications

Brandelero, Julio Cezar 28 May 2015 (has links)
L’électricité prend une place de plus en plus importante dans les systèmes énergétiques embarqués. L’électricité est une forme d’énergie très malléable, facile à transporter et réglable ou transformable avec un très faible taux de pertes. L’énergie électrique, associée à des convertisseurs statiques, est plus facile à maîtriser que, par exemple, l’énergie hydraulique et/ou pneumatique, permettant un réglage plus fin et une réduction des coûts de maintenance. L’évolution de la puissance dans les modèles avioniques est marquante. Avec le nombre croissant de charges électroniques, un avion plus électrique avec un réseau à courant alternatif inclurait un grand nombre de redresseurs AC/DC qui devront respecter les normes de qualité secteur. Une solution pour la réduction de la masse serait de préférer un réseau HVDC (High Voltage DC Bus). Sur les futurs modèles avioniques plus électriques, les concepteurs envisageront des conversions HVDC/DC à partir de l’unité appelée BBCU (Buck Boost Converter Unit). Dans ce cas d’étude, un réseau de distribution en tension continue (±270Vdc) est connecté à un réseau de sécurité basse tension (28Vdc) avec un échange bidirectionnel de puissance pouvant atteindre 10kW. Le convertisseur statique assurant cette liaison représente de nouveaux défis pour l’électronique de puissance en termes de fiabilité, sûreté, détection de panne, rendement et réduction de masse et de coût. Le dimensionnement du convertisseur doit prendre en compte une conception optimale, en aéronautique ce critère est la masse. Dans le processus de dimensionnement et d’optimisation du convertisseur, il est donc impératif de prendre en compte trois facteurs principaux : 1) l’évolution des topologies de conversion, 2) l’évolution des composants actifs et passifs et 3) l’intégration de puissance. La réunion de ces trois facteurs permettra ainsi la miniaturisation des convertisseurs statiques. Dans un premier temps, nous préciserons la démarche adoptée pour le dimensionnement d’un convertisseur en prenant en compte : les topologies actives, les filtres différentiels et le système de refroidissement. Les différents éléments qui composent le convertisseur sont décrits dans un langage informatique orienté objet. Des facteurs de performances seront également introduits afin de faciliter le choix des semi-conducteurs, des condensateurs et du dissipateur pour un convertisseur statique. Dans un deuxième temps, nous présenterons le fonctionnement d’une topologie multicellulaire DC/DC, isolée pour l’application proposée. Nous présenterons les avantages du couplage de différentes phases de ce convertisseur. Nous introduirons les différentes associations des cellules et leurs avantages, possibles grâce à l’isolement, comme la mise en série et en parallèle. Puisque la caractérisation des pertes des semi-conducteurs est essentielle pour le dimensionnement du convertisseur statique, nous proposerons deux approches : un modèle de simulation relativement simple et paramétré à l’aide de seules notices constructeurs ; et une méthode de mesure des pertes dans les semi-conducteurs qui est à la fois précise et compatible avec les composants les plus rapides. En ce qui concerne les composants magnétiques, une surface de réponse des matériaux ferrites sera présentée. Nous allons décrire, par le biais analytique et de simulation, des modèles pour la détermination du champ magnétique à l’intérieur du noyau et des ondulations de courant engendrés. Finalement, en profitant des modèles et des résultats obtenus dans les sections précédentes, nous montrerons le dimensionnement et la réalisation de chaque partie du convertisseur BBCU 100kHz / 10kW. Une perspective d’un design idéal est également présentée. / The electricity is taking a more important place in the embedded systems. The electricity is a very moldable form of energy, easy to transport and adjustable or transformed with a very low losses. The electrical energy, associated with power converters, is easier to control than hydraulic and/or pneumatic energies for example, allowing a finer regulation and a cost cutting of maintenance. The installed power in the avionic models is growing fast. With the increasing number of electronic loads, a more electrical aircraft with an AC network would include a large number of rectifiers AC/DC which will have to respect the quality standards. A solution for the reduction of the mass would be to prefer a HVDC network (High Voltage DC BUS). On the future more electrical aircrafts, the designers will be facing a HVDC/DC power conversion. This is the role of the unit called BBCU (Buck Boost Converter Unit). In our case of study, a distribution network in DC voltage (± 270Vdc) is connected to a security low-voltage network (28Vdc) which includes a bidirectional power exchanges achieving 10kW. The power converter for this connection gives new challenges for the power electronics in terms of reliability, safety, failure detection, efficiency and reduction of mass and cost. The design of the power converter needs to take into account for an optimal design. It is thus imperative to take into account three main factors: 1) the evolution of the power topologies 2) the evolution of the active and passive devices and 3) the power integration. The meeting of these three factors will allow the miniaturization of the power converters. At first, the adopted approach for designing power converters, taking into account the power topology, the differential filters and the cooling system are presented. The various elements which compose the power converter are described in an Object-Oriented Programming. The performance factors will be introduced to facilitate the choice of semiconductors, capacitors and heat-sinks. Secondly, the operation phases of a multicellular isolated DC/DC topology for the proposed application are presented. A discussion of the advantages of the magnetic coupling is also introduced. Thanks to the isolation, different associations of switching cells, series or/and parallel connection, are possible. Knowing the losses of power semiconductors is an essential step to design a power converter, thus two approaches are proposed: 1) a simulation model using a relatively simple model with the datasheets information; and 2) a losses measurement method which is precise and compatible with the fastest devices. As regards the magnetic components, a response surface of ferrite materials will be presented. Some models for the determination of the magnetic field inside the core and the current ripple are also described. Finally, by taking advantage of models and results obtained in the previous sections, the design and the realization of each party of the BBCU power converter 100kHz / 10kW is showed. A perspective of an ideal design is also presented.
104

Studies on Single DC Link Fed Multilevel Inverter Topologies by Cascading Flying Capacitor and Floating Capacitor Fed H-Bridges

Pappu, Roshan Kumar January 2014 (has links) (PDF)
Use of multilevel inverters are inevitable in medium and high voltage drives. This is due to the fact that the multilevel inverters can produce voltages in smaller steps which will reduce the harmonic content and result in more sinusoidal voltages and currents as compared to voltages and currents from two-level inverters. Due to the device limitations, use of two-level inverters is not possible in medium and high voltage drive applications. Though multiple devices can be connected both in series and parallel to achieve two-level operation, the output voltages still suffer from high harmonic content. Multilevel inverters have multiple DC voltage levels with switches that enable one of the voltage steps to be applied to the load. Due to decrease in step size during each switching instant, output voltages and currents of the multilevel inverters have considerably less harmonic content. As the number of levels increase, the switching step reduces thereby the harmonic content also reduces drastically. Due to their advantages, multilevel inverters have gained lot of acceptance in the industry even at lower voltages. The three main configurations that have gained popularity are the neutral point clamped converter, the flying capacitor converter and the cascaded H-bridge converter. Each converter has its own set of advantages and disadvantages. Based on the requirements of various applications, it is possible to fabricate hybrid multilevel topologies that are combinations of the three basic topologies. Researchers around the world have proposed several such converters for diverse applications so as to suit particular requirements like modularity, ease of control, improved reliability, fault tolerant capability etc. The present thesis explores multilevel converters with single DC link to be used for motor drive and grid connected applications. A novel five-level inverter topology formed by cascading a floating capacitor H-bridge module to a regular three-level flying capacitor inverter has been explored in chapter 2. The three-level flying capacitor inverter can generate pole voltages of 0, VDC /2 and VDC . By cascading it with another floating capacitor H-bridge of voltage magnitude VDC /4, pole voltages of 0, VDC /4, VDC/2, 3VDC /4 and VDC . Each of these pole voltage levels can have one or more switching combinations. However each switching combination has a unique effect on the state of the two capacitor voltages. By switching through redundant switching combinations for the same pole voltage, the two capacitors present in each phase can be balanced. The proposed topology also has an advantage that if one of the devices in the H-bridge fails, the topology can still be operated as a regular three-level flying capacitor inverter that can supply full load at rated power by bypassing the faulty H-bridge. This fault tolerant operation of the converter will enable it to be used in applications like traction and marine drives where high reliability is needed. The proposed converter needs a single DC link. All the required voltage levels can be generated from the single DC link. This enables back to back grid connected operation possible where multiple converters can interact with a single DC link. Various pole voltage switching combination and its effect on individual capacitor has been studied. A control algorithm to balance the capacitor voltages by switching through multiple redundancies for the same pole voltage has been developed. The proposed configuration has been implemented in hardware using IGBT H-bridge modules and the control circuitry is realized using DSP and FPGA. The performance of the drive is verified for various frequencies and modulation indices during steady state by running a three phase induction motor at no load. The stability of the drive during transients has been studied by accelerating the machine suddenly at no load and analyzing the performance of the drive. The capacitor voltages are made to deviate from their intended values and the capacitor balancing algorithm has been verified for its ability to bring the capacitor voltages back to their intended values. The experimental results have been presented and discussed in detail in the chapter 2. In the third chapter a common-mode voltage eliminated three-level inverter using a single DC link has been proposed. The power schematic is similar to the one presented in chapter 2. In this chapter the space vector polygon formed by the three phases of the proposed topology has been presented. The common-mode voltage generated by different pole voltage combinations for same space vector location and the redundant switching state combinations has been studied. The pole voltage combinations with zero common mode voltage have been studied. The switching state redundancies for the the pole voltage have been studied. The space vector polygon formed with the pole voltage combinations has been analyzed. A drive is made with the proposed common-mode voltage eliminated inverter. The performance of the drive is tested for various modulation indices and frequencies by running a three phase squirrel cage induction motor at no load. The transient performance is verified by accelerating the motor suddenly and checking the common-mode voltage along with the capacitor voltages. The results have been presented and discussed in detail in chapter 3. This converter has advantages like use of single DC supply, ability to operate as a regular three level converter in case of failure of one of the H-bridges. The work presented in fourth chapter proposes a novel three phase 17-level inverter configuration which utilizes a single DC supply. The rest of voltages are generated using three floating capacitor H-bridges. The redundant switching combinations for generating various pole voltages and their effect on the capacitors have been studied and suitable capacitor balancing algorithm has been developed. The proposed topology has been realized in hardware and the performance of the drive during steady state has been studied by running an induction motor at various modulation indices and frequencies. The transient response of the drive has been observed by accelerating the motor suddenly under no load. The results have been presented in detail in chapter four. This configuration also needs a single DC link. The advantages of this configuration is in case of failure of any devices in the H-bridge, the drive can be operated at reduced number of levels while supplying full load current. This feature helps the drive to be used in fault tolerant applications like marine and traction drives where reliability of the drive is of prime importance. All the topologies that have been presented in the previous chapters have mentioned about the usage of the proposed genre of topologies use single DC link and hence will enable back to back grid tied inverter connection. In the fifth chapter this has has been verified experimentally. The three phase squirrel cage induction motor is driven by using the seventeen-level inverter drive proposed in chapter four. A five-level active front-end is realized by the converter topology proposed in chapter two. The converter is run and the performance of the drive is studied at various modulation indices and speeds of the motor. Various aspects like re-generation operation, acceleration and other aspects of the drive have been studied experimentally and the results are presented in detail. For experimental setup, Semikron SKM75GB12T4 IGBT modules have been used to realize the power topology. These IGBTs are driven by M56972L drivers. The control circuit is realized using TMS320F2812 DSP along with Xilinx Spartan 3 FPGA (XC3S200) has been used. The voltages and currents are sensed using LEM LV-20P and LA 55-P hall effect based sensors.
105

Control, Modulation and Testing of High-Power Pulse Width Modulated Converters

Sivaprasad Sreenivasa, J January 2013 (has links) (PDF)
Experimental research on high-power converters, particularly in an academic environment, faces severe infrastructural constraints. Usually, power source and loads of required ratings are not available. Further, more importantly, the energy consumption is huge. One possibility is to establish an experimental research platform, comprising of a network of high-power converters, through which power is circulated and which draws only the losses from the mains. This work deals with the establishment of a circulating power test set-up, comprising of two line-side PWM converters, inclusive of control and modulation methods for the two converters. Two types of circulating power test setups are developed. In the first setup, the converters are connected in parallel, on ac as well as dc sides, such that real and/or reactive power is circulated between them. In the second test setup, the dc buses of the converters are separated; hence, only reactive power circulation is possible. These setups are used to conduct heat-run tests with low energy expenditure on the PWM converters at various operating conditions up to power levels of 150 kVA. Further, these are used to validate analytically-evaluated thermal characteristics of high-power PWM converters. A safe thermal limit is derived for such converters in terms of apparent power (kVA) handled, power factor and switching frequency. The effects of voltage sag and of unequal current sharing between parallel IGBT modules on the safe thermal limit are studied. While the power drawn by the circulating-power setup from the grid is much lower than the ratings of the individual converters, the harmonic injection into the mains by the setup could be significant since the harmonics drawn by both converters tend to add up. This thesis investigates carrier interleaving to improve the waveform quality of grid current, drawn by the circulating-power test setup. The study of carrier interleaving is quite general and covers various applications of parallel-connected converters such as unity power factor rectification, static reactive power compensation and grid-connected renewable energy systems. In literature, carrier interleaving has been employed mainly for unity power factor rectifiers, sharing a common dc load equally. In such case, the fundamental components of the terminal voltages of the parallel converters are equal. However, when the power sharing between the two converters is unequal, or when power is circulated between the two converters, the terminal voltages of the two converters are not equal. A method to estimate rms grid current ripple, drawn by parallel-connected converters with equal and/or unequal terminal voltages, in a synchronous reference frame is presented. Further, the influence of carrier interleaving on the rms grid current ripple is studied. The optimum interleaving angle, which minimizes the rms grid current ripple under various applications, is investigated. This angle is found to be a function of modulation index of the converters in the equal terminal voltages case. In the unequal terminal voltages case, the optimum interleaving angle is shown to be a function of the average modulation index of the two parallel converters. The effect of carrier interleaving is experimentally studied on the reactive power circulation setup at different values of kVA and different dc bus voltages. The grid current ripple is measured for different values of interleaving angle. It is found experimentally that the optimum interleaving angle reduces the rms grid current ripple by between 37% and 48%, as compared without interleaving, at various operating conditions. Further, the reactive power circulation test set-up is used to evaluate and compare power conversion losses corresponding to different PWM techniques such as conventional space-vector PWM (CSVPWM), bus-clamping PWM (BCPWM) and advanced bus-clamping PWM methods for static reactive power compensator (STATCOM) application at high power levels. It is demonstrated theoretically as well as experimentally that an advanced bus-clamping PWM method, termed minimum switching loss PWM (MSLPWM), leads to significantly lower power conversion loss than CSVPWM and BCPWM techniques at a given average switching frequency.
106

A Study of Experience Mapping Based Predictive Controller as Applied to Switching Converters

Nayak, Namratha January 2015 (has links) (PDF)
Experience Mapping based Prediction Control (EMPC) is a new type of controller presented in literature, which is based on the concept of Human Motor Control (HMC). During the developmental phase, called the initial learning phase, the controller records the experience in a knowledge base, through online interactions with the system to be controlled. This knowledge base created using the experience maps is termed as Experience Mapped Knowledge Base (EMK). The controller envisages the development of EMK only through interaction with the system, without the need for knowledge of the detailed plant model. The EMPC controls the system through prediction of actions based on the mapped experiences of EMK. Depending on the nature of control required for the system chosen, various strategies can be used to achieve control using the EMK. The above controller has previously been utilized for motion control applications. In the present work an effort has been made to study the suitability of the EMPC for the voltage regulation of switching converters. The plant chosen for the control study is a discontinuous conduction mode (DCM) buck converter. The parameter to be monitored for the purpose of control is the load voltage. The control input from the EMPC to the converter is a duty ratio value based pulse-width modulated (PWM) signal. Two strategies of control have been proposed: steady state control and transient control. Steady state control action maintains the steady state output voltage at the required value for a given load. The transient control action is used to improve the transient performance of the system. Iterative predictive action and iterative transient actions are used to facilitate convergence of the output voltage to within the required range in presence of non-linearities and uncertainties in the system. Impulse action is introduced to further improve the transient performance of the system. The EMPC is compared a proportional-integral (PI) controller for the given DCM buck system.
107

Integrated Common And Differential Mode Filters With Active Damping For Active Front End Motor Drives

Acharya, Anirudh B 01 1900 (has links) (PDF)
IGBT based power converters acts as front end in the present day Adjustable Speed Drive (ASD). This offers many advantages and makes regenerative action possible. PWM rectifier operation produces electrically noisy DC bus on common mode basis. This results in higher ground current as compared to three phase diode bridge rectifier. Due to fast turn-ON and turn-OFF time of IGBT, the inverter output voltage dv/dt is high during switching transients and voltage waveform is rich in harmonics. As a result, in applications involving long cable the motor terminal voltage during the switching transient is as high as twice the applied voltage. This voltage stress reduces the life of insulation in motors. The high dv/dt output voltage applied at the motor terminal excites the parasitic capacitive coupling resulting in increased ground currents and causes Electric Discharge Machining (EDM) which reduces the life of motor bearings. The common mode voltage due to PWM rectifier and the inverter appear at the motor terminals exacerbating these problems. The common mode voltage due to PWM inverter with PWM rectifier is analyzed. An integrated approach for filter design is proposed wherein the adverse effects due to common mode voltage of both AFE converter and the inverter is addressed. The proposed topology addresses the problems of common mode voltage, common mode current and voltage doubling due to ASD. The design procedure for proposed filter topology is discussed with experimental results that validate the effectiveness of the filter. Inclusion of such higher order filter in the converter topology leads to problems such as resonance. Passive methods are investigated for damping the line resonance due to LCL filter and common mode resonance due to common mode filter. The need for active damping technique for resonance due to common mode filter is presented. State space based damping technique is proposed to effectively damp the resonance due to line filter and the common mode filter. Experimental results are presented that validate the effectiveness of active damping both on the line basis (differential mode) and line to ground basis (common mode) of the filter.
108

Multilevel Dodecagonal Space Vector Structures and Modulation Schemes with Hybrid Topologies for Variable Speed AC Drives

Kaarthik, R Sudharshan January 2015 (has links) (PDF)
MULTILEVEL inverters are the preferred choice of converters for electronic power conversion for high power applications. They are gaining popularity in variety of industrial applications including electric motor drives, transportation, energy management, transmission and distribution of power. A large portion of energy conversion systems comprises of multilevel inverter fed induction motor drives. The multilevel inverters are ideal for such applications, since the switching frequency of the devices can be kept low. In conventional two level inverters, to get nearly sinusoidal phase current waveform, the switching frequency of the inverter is increased and the harmonics in the currents are pushed higher in the frequency spectrum to reduce the size and cost of the filters. But higher switching frequency has its own drawbacks – in particular for medium voltage, high power applications. They cause large dv_/ dt stresses on the motor terminals and the switching devices, leading to increased electromagnetic interference (EMI) problems and higher switching losses. Harmonics in the motor currents can further be minimized by adopting dodecagonal voltage space vector (SV) switching (12-sided polygon). In case of dodecagonal SV switching, the fifth and seventh order (6n , 1, n = odd) harmonics are completely eliminated for the full modulation range including over modulation and twelve step operation in the motor phase voltages and currents. In addition to low order harmonic current suppression, the linear modulation range for dodecagonal SV switching is also more by 6% when compared to that of the conventional hexagonal SV switching. The dodecagonal voltage SV structure is made possible by connecting two inverters with DC-link voltages Vd and 0:366Vd on either side of an open-end winding induction motor. The dodecagonal space vector switching can be used to produce better quality phase voltage and current waveforms and overcome the problem of low order fifth and seventh harmonic currents and to improve the range for linear modulation while reducing the switching frequency of the inverters when compared to that of the conventional hexagonal space vector based inverters. This thesis focuses on three aspects of multilevel dodecagonal space vector structures (i) Two new power circuit topologies that generate a multilevel dodecagonal voltage space vector structure with symmetric triangles, (ii) A multilevel dodecagonal SV structure with nineteen concentric dodecagons, (iii) Pulse width modulation (PWM) timing calculation methods for a general N-level dodecagonal SV structure. (i) Two new power circuit topologies capable of generating multilevel dodecagonal voltage space vector structure with symmetric triangles with minimum number of DC link power supplies and floating capacitor H-bridges are proposed. The first power topology is composed of two hybrid cascaded five level inverters connected to either side of an open end winding induction machine. Each inverter consists of a three level neutral point clamped (NPC) inverter, cascaded with an isolated capacitor fed H-bridge making it a five level inverter. The second topology is a hybrid topology for a normal induction motor (star or delta connected), where the power is fed to the motor only from one side. The proposed scheme retains all the advantages of multilevel topologies as well the advantages of the dodecagonal voltage space vector structure. Both topologies have inherent capacitor balancing for floating H-bridges for all modulation indices including transient operations. The proposed topologies do not require any pre-charging circuitry for startup. PWM timing calculation method for space vector modulation is also explored in this chapter. Due to the symmetric arrangement of congruent triangles within the voltage space vector structure, the timing computation requires only the sampled reference values and does not require any iterative searching, off-line computation, look-up tables or angle estimation. Experimental results for steady state operation and transient operation are also presented to validate the proposed concept. (ii) A multilevel dodecagonal voltage space vector structure with nineteen concentric do-decagons is proposed for the first time. This space vector structure is achieved by connecting two sets of asymmetric hybrid five level inverters on either side of an open-end winding induction motor. The dodecagonal structure is made possible by proper selection of DC-link voltages and switching states of the inverters. In addition to that, a generic and simple method for calculation of PWM timings using only sampled reference values (v and v ) is proposed. This enables the scheme to be used for any closed loop application like vector control. Also, a new switching technique is proposed which ensures minimum switching while eliminating the fifth and seventh order harmonics and suppressing the eleventh and thirteenth harmonics, eliminating the need for bulky filters. The motor phase voltage is a 24-stepped waveform for the entire modulation range thereby reducing the number of switchings of the individual inverter modules. Experimental results for steady state operation, transient operation including start-up have been presented and the results of Fast Fourier Transform (FFT) analysis is also presented for validating the proposed concept. (iii) A method to obtain PWM timings for a general N-level dodecagonal voltage space vector structure using only sampled reference values is proposed. Typical methods that are used to find PWM timings for dodecagonal SV structures use modulation index and the reference vector angle, to get the timings T1 and T2 using trigonometric calculations. This method requires look-up tables and is difficult to implement in closed loop systems. The proposed method requires only two additions to compute these timings. For multilevel case, typical iterative methods need timing calculations (matrix multiplications) to be performed for each triangle. The proposed method is generic and can be extended to any number of levels with symmetric structures and does not require any iterative searching for locating the triangle in which the tip of the reference vector lies. The algorithm outputs the triangle number and the PWM timing values of T0, T1 and T2 which can be set as the compare values for any carrier based PWM module to obtain space vector PWM like switching sequences. Simulation and experimental results for steady state and transient conditions have been presented to validate the proposed method. A 3.7 kW, 415 V, 50 Hz, 4-pole open-end winding induction motor was used for the experimental studies. The semiconductor switches that were used to realize the power circuit for the experiment were 75 A, 1200 V insulated-gate bipolar transistor (IGBT) half-bridge modules (SKM75GB12T4). Opto-isolated gate drivers with desaturation protection (M57962L) were used to drive the IGBTs. For the speed control and PWM timing computation a digital signal processor (DSP-TMS320F28335) with a clock frequency of 150 MHz was used. For modulation frequencies 10 Hz and below, a constant sampling frequency of 1 kHz was used as the frequency modulation ratio is high. For modulation frequencies above 10 Hz, synchronous PWM strategy was used. The time duration Ts is the sampling interval for which the timings T1 , T2 and T0 are calculated. As in the case of any synchronous PWM method, the duration of sampling time (Ts) is a function of the fundamental frequency of the modulating signal. In this case, Ts = 1_.fm • 12n) sec. where fm is fundamental frequency in Hertz and ‘n’ is the number of samples per 30ý dodecagonal sector. The PWM timings and the triangle data (from the DSP) is fed to field programmable gate array (FPGA) (SPARTAN XC3S200) clocked at 50 MHz where the actual gating pulses are generated. The capacitor balancing algorithm and the dead-time modules were implemented within FPGA. No external hardware was used for generation of dead-time. The dead-time block generates a constant dead-time of 2 s for all the switches. Extensive testing was done for steady state operations and transient operations including quick acceleration and start-up to validate the proposed concepts. With the advantages like extension of linear modulation range, elimination of fifth and seventh harmonics in phase voltages and currents for the full modulation range, suppression of eleventh and thirteenth harmonics in phase voltages and currents, reduced device voltage ratings, lesser dv_dt stresses on devices and motor phase windings, lower switching frequency, inherent cascaded H-bridge (CHB) capacitor balancing, the proposed space vector structures, the inverter power circuit topologies, the switching techniques and the PWM timing calculation methods can be considered as viable schemes for medium voltage, high power motor drive applications.
109

A new family of dc-dc-ac power electronics converters

Darabi, Mostafa January 2014 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This thesis proposes a family of non-isolated bidirectional converter in order to interface dc and ac variables. Such power electronics solutions guarantee: (i) bidirectional power flow between dc and ac converter sides, (ii) independent control in both converter sides, (iii) high level of integration with a reduction of one power switch and its drive circuits, (iv) implementation of two functions by using a unique power conversion stage and (v) reduction of the capacitor losses. Despite proposing new power converter solutions, this thesis presents an analysis of the converters in terms of pulse-width-modulation (PWM) strategy, dc-link capacitor variables, and suitable a control approach. Solutions for single-phase, three-phase and three-phase four-wire systems are proposed by employing a converter leg with three switches. A possible application of this converter is in Vehicle-to-Grid (V2G) systems and interfacing dc microgrid with a utility grid. In addition to the new power electronics converters proposed in this thesis, an experimental setup has been developed for validation of the simulated outcomes. The proof-of-concept experimental setup is constituted by: DSP, Drivers & Integrating Board, Power Supply and, Power Converter & Heat-Sink .
110

Ανάπτυξη δυναμικού μοντέλου και έλεγχος ανεμογεννήτριας συνδεδεμένης στο δίκτυο και σε αυτόνομη λειτουργία εφοδιασμένη με διάταξη αποθήκευσης ενέργειας

Δημητρακάκης, Στέφανος 18 June 2014 (has links)
Η παρούσα διπλωματική εργασία πραγματεύεται τη μελέτη και τη μοντελοποίηση ενός αιολικού συστήματος παραγωγής ηλεκτρικής ενέργειας βασισμένο σε σύγχρονη γεννήτρια μόνιμου μαγνήτη (PMSG). Ειδικότερα, παρουσιάζονται και αναλύονται όλα τα τμήματα που αποτελούν το αιολικό σύστημα καθώς και οι λογικές ελέγχου που ακολουθήθηκαν για την αποτελεσματική λειτουργία του. Επιπλέον, μελετάται και μοντελοποιείται μια διάταξη αποθήκευσης ενέργειας από την οποία πλαισιώνεται το αιολικό σύστημα κατά την αυτόνομη λειτουργία του. Τέλος, παρουσιάζονται και σχολιάζονται τα αποτελέσματα της προσομοίωσης της λειτουργίας του συστήματος, σε σύνδεση με το δίκτυο και κατά την αυτόνομη λειτουργία του. Για την ανάπτυξη του μοντέλου και την προσομοίωση χρησιμοποιήθηκε το πρόγραμμα Simulink/Matlab. Στο Κεφάλαιο 1 γίνεται αναφορά στο ενεργειακό πρόβλημα και μια γενική εισαγωγή στις ανανεώσιμες πηγές ενέργειας. Επιπλέον, δίνονται διάφορες πληροφορίες γύρω από την αιολική ενέργεια και αναλύονται τα πλεονεκτήματα και μειονεκτήματα της χρήσης ανεμογεννητριών. Επίσης, παρουσιάζεται η δομή μιας ανεμογεννήτριας και παραθέτονται διάφοροι τύποι ανεμογεννητριών, ενώ δίνονται και οι βασικές σχέσεις μετατροπής της αιολικής ενέργειας σε ηλεκτρική. Στο Κεφάλαιο 2 γίνεται ανάλυση κάθε τμήματος της ανεμογεννήτριας (πτερωτή, σύστημα μετάδοσης κίνησης, γεννήτρια) και παρατίθενται οι εξισώσεις που περιγράφουν τη λειτουργία τους. Επιπρόσθετα, παρουσιάζεται ο τρόπος μοντελοποίησης του κάθε τμήματος στο περιβάλλον του Simulink. Ιδιαίτερη έμφαση δόθηκε στη μελέτη της σύγχρονης γεννήτριας μόνιμου μαγνήτη καθώς παρουσιάζεται με λεπτομέρεια η δομή της καθώς και οι αρχές που διέπουν τη λειτουργία της. Τέλος, δίνονται όλα τα χαρακτηριστικά μεγέθη της ανεμογεννήτρια που χρησιμοποιήθηκε στην παρούσα εργασία. Στο Κεφάλαιο 3 αρχικά, γίνεται μια γενική παρουσίαση των στοιχείων που αποτελούν τους μετατροπείς, ενώ στη συνέχεια παρουσιάζονται οι βασικές κατηγορίες μετατροπέων που υπάρχουν και αναφέρονται μερικοί βασικοί τύποι μετατροπέων που βρίσκουν εφαρμογή σε αιολικά συστήματα γενικότερα. Έπειτα, το κεφάλαιο επικεντρώνεται στους μετατροπείς που χρησιμοποιήθηκαν στο αιολικό σύστημα της παρούσας εργασίας καθώς εξηγείται ο τρόπος λειτουργίας τους και παρουσιάζεται ο τρόπος μοντελοποίησης τους στο Simulink. Έμφαση δόθηκε στον dc/dc μετατροπέα ανύψωσης τάσης που χρησιμοποιήθηκε, όπου γίνεται διαστασιολόγηση και παρουσιάζεται μια μικρή προσομοίωση της λειτουργίας του. Τέλος, παρουσιάζεται, επίσης, το φίλτρο που τοποθετείται στην έξοδο του αντιστροφέα. Στο Κεφάλαιο 4 περιγράφονται αναλυτικά η τεχνική διαμόρφωσης εύρους παλμών (PWM) και η τεχνική της ημιτονοειδούς διαμόρφωσης εύρους παλμών (SPWM), οι οποίες και εφαρμόστηκαν για την παλμοδότηση των μετατροπέων. Στη συνέχεια, περιγράφονται αναλυτικά οι μηχανισμοί ελέγχου που εφαρμόστηκαν με τη βοήθεια PI ελεγκτών, τόσο στην πλευρά της μηχανής (dc/dc μετατροπέας ανύψωσης τάσης) όσο και στον αντιστροφέα του αιολικού συστήματος. Στο Κεφάλαιο 5 παρουσιάζονται και σχολιάζονται τα αποτελέσματα της προσομοίωσης του αιολικού συστήματος σε σύνδεση με το δίκτυο. Το σύστημα προσομοιώνεται για δύο περιπτώσεις, σε πρώτη φάση γίνεται προσομοίωση του συστήματος υπό σταθερή ταχύτητα ανέμου ίση με 12 m/s και σε δεύτερη φάση προσομοιώνεται η λειτουργία του συστήματος για βηματικές μεταβολές της ταχύτητας του ανέμου. Στο Κεφάλαιο 6 μελετάται η αυτόνομη λειτουργία του αιολικού συστήματος το οποίο, πλέον, πλαισιώνεται με μια διάταξη αποθήκευσης ενέργειας. Αρχικά, παρουσιάζεται το σύστημα αποθήκευσης ενέργειας που χρησιμοποιήθηκε. Συγκεκριμένα η συστοιχία μπαταριών της οποίας δίνονται τα χαρακτηριστικά μεγέθη, καθώς και το μοντέλο της στο Simulink. Επίσης, παρουσιάζεται και μοντελοποιείται ο dc/dc μετατροπέας δύο κατευθύνσεων ο οποίος συνδέει τη συστοιχία με το υπόλοιπο σύστημα. Στη συνέχεια, περιγράφεται αναλυτικά ο μηχανισμός ελέγχου που εφαρμόζεται στη διάταξη αποθήκευσης ενέργειας για τον έλεγχο της φόρτισης/εκφόρτισης. Στο τέλος του κεφαλαίου παρουσιάζονται τα αποτελέσματα της προσομοίωσης του αυτόνομου αιολικού συστήματος για σταθερή ταχύτητα ανέμου-μεταβαλλόμενο φορτίο και για μεταβαλλόμενο άνεμο-σταθερό φορτίο. / In this thesis, a wind energy conversion system (WECS) based on a permanent magnet synchronous generator (PMSG) was studied and simulated. All parts of the WECS are presented and discussed in detail. Furthermore, control strategies for the generator-side converter and the voltage source inverter are developed. The WECS is simulated both in grid connected and stand-alone mode. In the stand-alone mode, the WECS is supplied with an energy storage system for which a bi-directional buck/boost converter and control strategy was designed. Finally, simulation results are presented and performance of the system in various modes of operation is evaluated. Simulink/Matlab is used for modeling and simulating the WECS. At the beginning of Chapter 1, a discussion of energy crisis and renewable energy sources is held. Furthermore, information about wind energy has been reviewed and its benefits and drawbacks are examined. In addition, the structure of a wind turbine and the principles of converting wind energy into electricity are presented. In Chapter 2 all parts of the wind turbine are studied and its characteristics are specified. Even more, the model of every part in Simulink is presented. Theoretical background, structure and operation principles of PMSG are presented in detail. In Chapter 3, firstly a general presentation of converters components takes place. Then the major existing categories of converter are presented and some basic types of converters, which are generally used in WECS, are mentioned. Moreover, the chapter focuses on the converters that are used in this thesis, explaining the way they operate. After all, their models in Simulink are shown. Emphasis was given to the dc/dc boost converter whose parameters are calculated and its operation is simulated. Finally, there is a presentation of the filter which was placed at the output of the inverter. In Chapter 4, Pulse-width Modulation (PWM) and Sinusoidal Pulse-width Modulation (SPWM) techniques that are used in this thesis are described. Moreover, the control strategy for the generator-side converter with maximum power extraction is presented. The control strategy of the voltage sourced inverter is shown as well. In Chapter 5 simulation results of the grid connected WECS are presented and evaluated. On the first part of the presentation, the WECS is simulated for constant wind speed (12m/s), and in the second part for step-changed wind speed. In Chapter 6 the stand-alone operation of the WECS is studied and supplied with an energy storage system. Initially, there is an analysis of the energy storage system, which was used, and in particular the battery bank, whose characteristics are given. Moreover, a Bi-directional dc/dc Buck-Boost converter which is used to interconnect the battery bank to the dc-link is presented and modeled. Afterwards, there is a detailed description of the control strategy used in order to control charging / discharging of the battery bank. At the end of this chapter, simulation results of two different stand-alone operation modes are presented, one with constant wind speed and variable load and the other one with step-changing wind speed and constant load.

Page generated in 0.1352 seconds