• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 428
  • 3
  • 1
  • Tagged with
  • 434
  • 296
  • 107
  • 67
  • 62
  • 58
  • 53
  • 48
  • 46
  • 44
  • 38
  • 36
  • 34
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

SIMVEP - Simulador da Ventilação pulmonar

Moreira, Cristiane Maria Menezes 12 April 1996 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-21T11:29:42Z (GMT). No. of bitstreams: 1 Moreira_CristianeMariaMenezes_M.pdf: 7033608 bytes, checksum: 1ec3a6cbfdf88a0be5c1032255d950da (MD5) Previous issue date: 1996 / Resumo: Foi desenvolvido um programa para simular o circuito pulmonar de um paciente com suporte ventilatório. O Simulador da Ventilação Pulmonar (SIMVEP) é um programa para ser executado sob o ambiente operacional MS Windows e torna-se ferramenta para treinamento de profissionais ligados à ventilação pulmonar artificial (médicos, enfermeiros e fisioterapeutas entre outros). A execução do programa é em tempo real permitindo que a cada ação do usuário sob o sistema (por exemplo, alterando parâmetros do ventilador), resultados desta ação sejam apresentados na tela imediatamente. Estes resultados são gráficos com as curvas de pressão, fluxo e volume e os seguintes valores calculados: pressão proximal de pico, pressão alveolar de pico, trabalho, relação tempo inspiratórioltempo expiratório, constantes de tempo das unidades pulmonares esquerda e direita / Abstract: It has been developed a computer program to simulate a patient pulmonary circuit under ventilatory support. The Pulmonary Ventilation Simulator (SIMVEP) runs under MS Windows and is a useful tool for trainning ali the professionals linked to artificial ventilation (physicians, nurses and physiotherapists, amongst others). The real time execution of SIMVEP allows its user to immediatly see the results of any change in the ventilation parameters. SIMVEP on screen results are pressure, volume and flow curves and the following calculated values: peak proximal pressure, peak alveolar pressure, work, inspiratory time, inpiratory/expiratory time relation and right and left pulmonary ventilation units time constants / Mestrado / Mestre em Engenharia Elétrica
112

Comparação entre dois metodos de retirada do suporte ventilatorio em pacientes no pos-operatorio de cirurgia cardiaca

Figueiredo, Luciana Castilho de 17 December 2001 (has links)
Orientador : Sebastião Araujo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-01T12:43:08Z (GMT). No. of bitstreams: 1 Figueiredo_LucianaCastilhode_M.pdf: 1122397 bytes, checksum: 5938ba213ec8ac542fef5973219a9d76 (MD5) Previous issue date: 2001 / Resumo: INTRODUÇÃO. Pacientes no pós-operatório (PO) de cirurgia cardíaca eletiva de revascularização do miocárdio (RM) não apresentam grandes dificuldades quanto ao desmame do suporte ventilatório, porém não há na literatura um consenso quanto à melhor técnica e o melhor momento para a extubação. OBJETIVO. Comparar dois métodos de retirada do suporte ventilatório mecânico em pacientes submetidos à cirurgia cardíaca de RM não complicada, através da avaliação de parâmetros clínicos, ventilatórios e de trocas gasosas pulmonares. LOCAL. Unidade de Terapia Intensiva do Hospital de Clínicas da Universidade Estadual de Campinas. PERÍODO. Agosto de 2000 a maio de 2001. DESENHO. Estudo prospectivo, randomizado e intervencionista. METODOLOGIA. Quarenta e oito pacientes em PO de RM foram incluídos na presente pesquisa, e aleatoriamente divididos em dois grupos: grupo estudo (N = 24), que foram extubados diretamente, e grupo controle (N = 24), que foram extubados após um período de 30 minutos de ventilação espontânea com tubo em ¿T¿. Parâmetros clínicos, ventilatórios e de troca gasosa pulmonar foram anotados durante os procedimentos. RESULTADOS. Os valores são expressos como média ± DP. A maioria da população estudada foi constituída de indivíduos do sexo masculino (70,8% no grupo estudo e 66,7% no grupo controle; p = NS), com idade média em torno de 60 anos (56,7 ± 8,8 anos no grupo estudo e 58,6 ± 10,7 anos no grupo controle; p = NS). A P0,1 (cmH2O) foi de 3,0 ± 1,3 no grupo estudo e de 2,6 ± 1,0 no grupo controle (p = NS). O valor do Índice de Tobin para o grupo estudo foi de 31,4 ± 10,6 e de 36,5 ± 12,9 para o grupo controle (p = NS). O valor médio da PImáx (cmH2O) inicial para o grupo estudo foi de ¿34,4 ± 12,9 e de ¿31,8 ± 10,2 para o grupo controle (p = NS). O tempo do desmame do suporte ventilatório foi de 6,8 ± 1,9h para o grupo estudo e de 7,3 ± 2,5h para o grupo controle (p = NS). Dentre as medidas de mecânica respiratória, a FR (ipm) apresentou um aumento entre os momentos inicial e final dentro de cada grupo, sendo que o grupo estudo obteve um valor médio no momento inicial de 15,4 ± 3,3 e no momento final de18,2 ± 3,4; e o grupo controle obteve um valor médio no momento inicial de 16,9 ± 3,6 e momento final de 18,9 ± 3,9. O mesmo ocorreu com o VC (ml), sendo que o grupo estudo obteve um valor médio no momento inicial de 529,2 ± 146,6 e no momento final de 612,5 ± 159,6; e o grupo controle obteve um valor médio no momento inicial de 502,1 ± 147,1 e no momento final de 581,2 ± 192,7 (p = 0,0001). A PImáx (cmH2O) apresentou uma pequena mas significativa diferença dentro de cada grupo em ambos os tempos (de ¿34,4 ? 12,9 a ¿30,2 ? 10,5 no grupo estudo, e de ¿31,8 ? 10,2 para ¿29,7 ? 10,7 no grupo controle; p = 0,0356). Quanto aos parâmetros de troca gasosa pulmonar, não foram observadas diferenças estatisticamente significativas entre os grupos em nenhum momento. Também, dentro do grupo estudo, não foram observadas diferenças significativas considerando-se os momentos inicial e final. No entanto, no grupo controle houve uma queda significativa estatisticamente nos valores da PaO2 (112,3 ± 30,5 versus 103,3 ± 33,1mmHg; p = 0,0159), da SaO2 (97,8 ± 1,6 versus 97,0 ± 2,3%; p = 0,0171) e da PaO2/FiO2 (280,8 ± 76,2 versus 258,3 ± 82,7mmHg; p = 0,0340), quando comparados os momentos final com o inicial. O Índice Respiratório também apresentou piora em seus valores no grupo controle, comparando-se os momentos inicial e final (1,28 ± 0,65 versus 1,54 ± 0,82; p = 0,0106). CONCLUSÕES. Ambos os métodos foram comparáveis em relação ao tempo de desmame e à segurança clínica, nesse grupo de pacientes de cirurgia de RM não complicada. Porém, observou-se uma piora estatisticamente significativa de alguns parâmetros utilizados para a avaliação da troca gasosa pulmonar dentro do grupo conduzido ao desmame pelo tubo em ¿T¿. Dessa forma, em se dispondo de recursos, recomenda-se que, nos pacientes em pós-operatório de RM não complicada, o desmame ventilatório seja feito diretamente, sem a necessidade do uso do tubo ¿T¿, por ter esse último método se mostrado, além de desnecessário, potencialmente deletério em relação aos parâmetros de oxigenação sangüínea / Abstract: NTRODUCTION. Usually, there is no weaning difficulty in mechanical ventilated post-operative coronary artery bypass grafting (CABG) patients, but the literature is not consensual in relation to the best weaning method and the ideal moment for extubation. OBJECTIVE. To compare two weaning methods in uncomplicated CABG post-operative patients by evaluating clinical, ventilatory and pulmonary gas exchange parameters. SETTING. A general adult intensive care unit of a teaching hospital at Campinas State University. DESIGN. a prospective, randomized, interventional study. METHODOLOGY. Forty eight adult, both sexes, post-operative CABG patients were included in this trial, and randomly divided in: 1) study group (N = 24): patients were submitted to direct extubation; and 2) control group (n = 24): patients were extubated after a 30min breathing period on a ¿T¿ piece. Some clinical, ventilatory and pulmonary gas exchange parameters were measured and registered at the end of the weaning process (initial values) and 30min after extubation (final values). RESULTS. Values are expressed as (mean ? SD). The vast majority of patients were male (70.8% in the study group and 66.7% in the control group; p = NS), aging aroud 60 years (56.7 ? 8.8 years in the study goup and 55.8 ? 10.7 years in the control group). P0.1 (3.0 ? 1.3 versus 2.6 ? 1.0 cmH2O), Tobin Index (31.4 ? 10.6 versus 36.5 ? 12.9) and Pimax (-34.4 ? 12.9 versus -31.8 ? 10.2 cmH2O) were similar in the study and control group before extubation (p = NS). Time-to-wean was 6.8 ? 1.9h in the study group and 7.3 ? 2.5h in the control group (p = NS). In relation to mechanical respiratory parameters, respiratory rate (RR ¿ ipm) increased in both groups (from 15.4 ? 3.3 to 18.2 ? 3.4 in the study group, and from 16.9 ? 3.7 to 18.9 ? 3.9 in the control group; p = 0.0001) as did Tidal Volume (TV ¿ ml) (from 529.2 ? 146.4 to 612.5 ? 159.6 in the study group, and from 502.1 ? 147.1 to 581.2 ? 192.7 in the control group; p = 0.0001), when considering the initial and the final moments of measurements. On the contrary, a small but significant decreases in Pimax (cmH2O) were observed in both groups (from ¿34.4 ? 12.9 to ¿30.2 ? 10.5 in the study group, and from ¿31.8 ? 10.2 to ¿29.7 ? 10.7 in the control group; p = 0.0356). In relation to pulmonary gas exchange parameters, both groups were comparable, without differences between them (p = NS). However, in the control group, some kind of worsening in these parameters were observed when the values obtained at the final moment were compared to those of the initial moment. These data were statistically significant in relation to PaO2 (112.3 ? 30.5, initial versus 103.3 ? 33.1 mmHg, final; p = 0.0159), SaO2 (97.8 ? 1.6, initial versus 97.0 ? 2.3 %, final; p = 0.0171); PaO2/FiO2 (280.8 ? 76.2, initial versus 258.3 ? 82.7, final; p = 0.0340). Respiratory Index has also shown this same tendency (1.28 ? 0.65, initial versus 1.54 ? 0.89, final; p = 0.0106). CONCLUSIONS. Both weaning methods were comparable in relation to the time-to-wean and clinical safety in these post-operative CABG patients. However, some kind of worsening in pulmonary gas exchange parameters was observed in the ¿T¿ piece weaning group. Thus, our data suggest that uncomplicated post-operative CABG patients may be directly extubated according to a step-by-step weaning protocol, without needing to spent a time in a ¿T¿ piece, since this method has shown to be useless and potentially deleterious to pulmonary gas exchange / Mestrado / Pesquisa Experimental / Mestre em Cirurgia
113

Influência da administração de metilprednisolona na atividade inflamatória e no estresse oxidativo de pulmões de ratos submetidos a morte encefálica

Pilla, Eduardo Sperb January 2011 (has links)
O transplante pulmonar é terapia estabelecida para pacientes portadores de doença pulmonar em estágio terminal. Os doadores em morte encefálica são a principal fonte de pulmões para transplante. A fisiopatologia da encefálica é complexa e envolve mecanismos simpático, hemodinâmico e inflamatório que determinam o dano pulmonar. A administração de metilprednisolona em modelo animal de morte encefálica e transplante pulmonar diminuiu o dano de reperfusão no enxerto. Métodos- Vinte e quatro ratos Wistar foram anestesiados e randomizados em 4 grupos (n=6): Sham (sham): apenas trepanação; Morte Encefálica (ME): indução de morte encefálica e administração de solução salina; Corticóide 5min (mt5): indução de morte encefálica e após 5min administração de MET e Grupo Corticóide 60min (mt60): indução de morte encefálica e após 60min. administração de MET. Os animais de todos os grupos foram observados e ventilados durante 120min. Avaliou-se dados hemodinâmicos e gasométricos; dosagem de LDH, proteínas totais e citológico diferencial no lavado broncoalveolar (LBA); escore histológico; dosagem de substâncias reativas ao ácido tiobarbitúrico (TBARS), TNF-α, superóxido dismutase (SOD) e catalase em tecido pulmonar. Resultados- Não foi observado diferença estatística entre os grupos nos dados hemodinâmicos e gasométricos, dosagens do LBA, avaliação do escore histológico, dosagem de SOD e catalase. O TBARS aumentou significativamente (P<0,001) em ambos os grupos tratados com MET em relação aos grupos sham e ME. O TNF-α aumentou significativamente (P<0,001) no grupo ME em relação aos grupos tratados com MET. Não ocorreu diferença estatística entre os grupos mt5 e mt60. Conclusão- A administração precoce ou tardia de MET nesse modelo de morte encefálica resulta em efeitos similares nas atividades inflamatória e de peroxidação lipídica no tecido pulmonar. / Lung transplantation is an established therapy for patients with end-stage lung disease. The main source of lungs for transplantation is brain-dead donors. The pathophysiology of brain death is complex and involves sympathetic, hemodynamic and inflammatory mechanisms that can injure the lung. It has been previously shown that brain-dead donor treatment with methylprednisolone reduces reperfusion injury after lung transplantation in animals. We hypothesized that early administration of methylprednisolone after brain death could result in reduced lung inflammatory injury in the donor lung. METHODS: Twenty-four Wistar rats were anesthetized and randomly allocated into four groups (n=6): Sham (sham), Brain Death (BD), methylprednisolone 5min. (mt5) and methylprednisolone 60min. (mt60). BD, met5 and met60 groups were submitted to brain death by extradural space balloon inflation. Methylprednisolone (i.v. 30mg/kg) was administered to met5 and met60 groups, 5 or 60 minutes after brain death confirmation, respectively. The animals of all groups were observed and ventilated for 120 minutes. Hemodynamics, arterial blood gases, wet/dry weight ratio, bronchoalveolar lavage (white cell count, total protein and LDH concentration), histological score, superoxide dismutase (SOD) and catalase determination were analyzed. Lipid peroxidation and TNF-α determination were assessed in lung tissue. RESULTS: No significant differences were observed in hemodynamics, arterial blood gases, wet/dry weight ratio, bronchoalveolar lavage analysis, histological score, SOD and catalase in the different groups. TBARS determination was statistically higher in both methylprednisolone groups when compared to sham (p<0.001) and BD (p<0.001) groups. TNF-α concentration was significantly lower in met5 (p<0.001) and met60 groups (p<0.001) when compared to BD group. CONCLUSIONS: We conclude that early or late administration of methylprednisolone in this model of brain death has similar effect regarding inflammatory and lipid peroxidation activity on lung tissue.
114

Análise estatística baseada na construção de árvores de classificação e regressão de microRNAs de pacientes com adenocarcinoma pulmonar

Camargo, Bethina da Rocha January 2020 (has links)
Orientador: Rogério Antonio de Oliveira / Resumo: O adenocarcinoma pulmonar é um problema mundial na saúde pública e representa uma das maiores causa de morte por câncer no mundo. Os microRNAs são grandes reguladores e têm sido propostos como biomarcadores em diversos tipos de cânceres. O objetivo desta pesquisa é encontrar possíveis microRNAs para melhorar a classificação dos tecidos (normal ou tumoral) e a sobrevivência dos pacientes. Utilizou-se o banco de dados do projeto Atlas do Genoma do Câncer (TCGA) para pacientes com adenocarcinoma pulmonar (LUAD). A análise estatística empregada foi baseada na construção de árvores de classificação, que encontrou o miR-21-5p, miR-133a-3p, miR-1287-3p e let-7g-3p estatisticamente significativos, e árvore de regressão para a sobrevivência dos pacientes, que encontrou o miR-887-3p, miR-1271-5p, miR-128-1-5p, miR-493-3p e miR-4999-5p estatisticamente significativos. / Abstract: Pulmonary adenocarcinoma is a worldwide public health problem and represents one of the biggest causes of cancer death in the world. MicroRNAs are strong regulators and have been proposed as biomarkers in several types of cancer. The objective of this research is to find possible microRNAs to improve the classification of tissues (normal or tumor) and patient survival. We used the database of the Atlas of Cancer Genome project (TCGA) for patients with pulmonary adenocarcinoma (LUAD). A statistical analysis employed was based on the construction of classification trees, which found miR-21-5p, miR-133a-3p, miR-1287-3p and let-7g-3p, with statistical classification, and regression tree for the situation of patients, who found miR-887-3p, miR-1271-5p, miR-128-1-5p, miR-493-3p and miR-4999-5p are statistically used. / Mestre
115

Determinação do contorno pulmonar orientado em sequências temporais de imagens de RM pela transformada de Hough. / Oriented lung contour determination for temporal MRI sequences using hough transform.

Chirinos, José Miguel Manzanares 13 November 2015 (has links)
O estudo do movimento pulmonar é assunto de grande interesse na área médica. A observação direta do mesmo é inviável, uma vez que o pulmão colapsa quando a caixa torácica é aberta. Dentre os meios de observação indireta, escolheu-se o imageamento por ressonância magnética em respiração livre e sem uso de nenhum gás para melhorar o contraste ou qualquer informação de sincronismo. Esta escolha propõe diversos desafios, como: a superar a alta variação na qualidade das imagens, que é baixa, em geral, e a suscetibilidade a artefatos, entre outras limitações a serem superadas. Imagens de Tomografia Computadorizada apresentam melhor qualidade e menor tempo de aquisição, mas expõem o paciente a níveis consideráveis de radiação ionizante. É apresentada uma metodologia para segmentação do pulmão, produzindo um conjunto de pontos coordenados. Isto é feito através do processamento temporal da sequência de imagens de RM. Este processamento consiste nas seguintes etapas: geração de imagens temporais (2DSTI), transformada de Hough modificada, algoritmo de contornos ativos e geração de silhueta. A partir de um dado ponto, denominado centro de rotação, são geradas diversas imagens temporais com orientações variadas. É proposta uma formulação modificada da transformada de Hough para determinar curvas parametrizadas que sejam síncronas ao movimento diafragmático, chamados movimentos respiratórios. Também são utilizadas máscaras para delimitar o domínio de aplicação da transformada de Hough. São obtidos movimentos respiratórios que são suavizados pelo algoritmo de contornos ativos e, assim, permitem a geração de contornos para cada quadro pertencente a sequência e, portanto, de uma silhueta do pulmão para cada sequência. / Lung movement visualization is of great interest in medicine. Direct observation of the lung movement is not practicable, as it collapses if the thoracic cage is opened. Among indirect observation means, we choose magnetic resonance imaging, acquired on free breathing, without the use of any triggering information and any special gas to enhance the contrast. This choice leads us to overcome the high variation on MR images\' quality, which is, generally, low, and, also, artifact susceptibility, among other limitations. Computed Tomography images have better quality and a shorter acquisition time, but they expose the subject to considerably high levels of radiation. A Lung segmentation methodology is presented and it produces a connected set of points. That is achieved through MRI sequences temporal processing and it consists of the following stages: masks generation, 2-dimensional space-time images (2DSTI), modified Hough transform, an active contours algorithm and silhouette generation. Using a given point, which will be called parameter point, various temporal images with varied orientation will be generated. A modified Hough transform is applied to extract parameterized curves, that are synchronous to diaphragmatic movement, which will be called respiratory movements. Also, masks will be used in order to delimit the modified Hough transform application domain. An active contours algorithm will smoothen the obtained respiratory movements, so they will allow the generation of a contour for each frame on the image sequence and, therefore, a lung silhouette for a given sequence.
116

Avaliando a heurística de sequenciamento da produção dos métodos Tambor-Pulmão-Corda simplificado e gerenciamento do pulmão em um ambiente de produção para estoque / Evaluating the production sequencing heuristics of the simplified Drum-Buffer-Rope methods and buffer management in a make-to-stock environment

Jorge, Tiago da Cunha 30 November 2017 (has links)
Submitted by TIAGO DA CUNHA JORGE null (tiago.jorge1984@gmail.com) on 2018-01-09T15:54:47Z No. of bitstreams: 1 Dissertacao Final Tiago da Cunha Jorge.pdf: 4224244 bytes, checksum: a8bc587a448d3ec8a242dfd59cfc9591 (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-01-10T13:10:39Z (GMT) No. of bitstreams: 1 jorge_tc_me_bauru.pdf: 4224244 bytes, checksum: a8bc587a448d3ec8a242dfd59cfc9591 (MD5) / Made available in DSpace on 2018-01-10T13:10:39Z (GMT). No. of bitstreams: 1 jorge_tc_me_bauru.pdf: 4224244 bytes, checksum: a8bc587a448d3ec8a242dfd59cfc9591 (MD5) Previous issue date: 2017-11-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho tem como objetivo avaliar, por meio de simulação computacional, a regra de sequenciamento de ordens de produção recomendada pelo método Tambor-Pulmão-Corda Simplificado/Gerenciamento do Pulmão (Simplified Drum-Buffer-Rope / Buffer Management - S-DBR/BM) aplicado em ambientes de produção para estoque. Esta aplicação recebe o nome de Make to Availability (MTA), pois visa a um compromisso de atendimento da demanda baseado na pronta-entrega de produtos acabados. Para tanto, tal regra será comparada com as regras de sequenciamento da produção SPT (Shortest Processing Time), FIFO (First in First Out) e random. Para cumprir tal objetivo, será simulada uma fábrica real de manufatura contendo diferentes níveis de demanda e diferentes níveis de coeficiente de variação (CV) da demanda. A variável dependente utilizada para comparação dos desempenhos é o fill rate, que mensura o atendimento da demanda a partir do estoque de produtos acabados. Os resultados indicam que a regra S-DBR/MTA supera os demais métodos em todos os cenários simulados e também que cenários com menor CV da demanda apresentaram melhor fill rate médio que aqueles com maior CV. / This dissertation evaluated by computer simulation the production order sequencing rule recommended by the Simplified Drum-Buffer-Rope (S-DBR) applied in make-to-stock environments, called Make to Availability (MTA). MTA method aims at a commitment to meet demand based on the finished products prompt delivery. For this purpose, we compared it with SPT (Shortest Processing Time) sequencing heuristic, FIFO (First In First Out) and random sequencing rules, through demand patterns variations of a real factory. Fill rate was the dependent variable used to compare performances, which is the percentage of demand that is fulfilled directly out of the finished product stock. We show that S-DBR / MTA sequencing rule overcame all other sequencing rules and SPT had the worst fill rate.
117

Determinação do contorno pulmonar orientado em sequências temporais de imagens de RM pela transformada de Hough. / Oriented lung contour determination for temporal MRI sequences using hough transform.

José Miguel Manzanares Chirinos 13 November 2015 (has links)
O estudo do movimento pulmonar é assunto de grande interesse na área médica. A observação direta do mesmo é inviável, uma vez que o pulmão colapsa quando a caixa torácica é aberta. Dentre os meios de observação indireta, escolheu-se o imageamento por ressonância magnética em respiração livre e sem uso de nenhum gás para melhorar o contraste ou qualquer informação de sincronismo. Esta escolha propõe diversos desafios, como: a superar a alta variação na qualidade das imagens, que é baixa, em geral, e a suscetibilidade a artefatos, entre outras limitações a serem superadas. Imagens de Tomografia Computadorizada apresentam melhor qualidade e menor tempo de aquisição, mas expõem o paciente a níveis consideráveis de radiação ionizante. É apresentada uma metodologia para segmentação do pulmão, produzindo um conjunto de pontos coordenados. Isto é feito através do processamento temporal da sequência de imagens de RM. Este processamento consiste nas seguintes etapas: geração de imagens temporais (2DSTI), transformada de Hough modificada, algoritmo de contornos ativos e geração de silhueta. A partir de um dado ponto, denominado centro de rotação, são geradas diversas imagens temporais com orientações variadas. É proposta uma formulação modificada da transformada de Hough para determinar curvas parametrizadas que sejam síncronas ao movimento diafragmático, chamados movimentos respiratórios. Também são utilizadas máscaras para delimitar o domínio de aplicação da transformada de Hough. São obtidos movimentos respiratórios que são suavizados pelo algoritmo de contornos ativos e, assim, permitem a geração de contornos para cada quadro pertencente a sequência e, portanto, de uma silhueta do pulmão para cada sequência. / Lung movement visualization is of great interest in medicine. Direct observation of the lung movement is not practicable, as it collapses if the thoracic cage is opened. Among indirect observation means, we choose magnetic resonance imaging, acquired on free breathing, without the use of any triggering information and any special gas to enhance the contrast. This choice leads us to overcome the high variation on MR images\' quality, which is, generally, low, and, also, artifact susceptibility, among other limitations. Computed Tomography images have better quality and a shorter acquisition time, but they expose the subject to considerably high levels of radiation. A Lung segmentation methodology is presented and it produces a connected set of points. That is achieved through MRI sequences temporal processing and it consists of the following stages: masks generation, 2-dimensional space-time images (2DSTI), modified Hough transform, an active contours algorithm and silhouette generation. Using a given point, which will be called parameter point, various temporal images with varied orientation will be generated. A modified Hough transform is applied to extract parameterized curves, that are synchronous to diaphragmatic movement, which will be called respiratory movements. Also, masks will be used in order to delimit the modified Hough transform application domain. An active contours algorithm will smoothen the obtained respiratory movements, so they will allow the generation of a contour for each frame on the image sequence and, therefore, a lung silhouette for a given sequence.
118

Efeitos pulmonares da hemodiluição normovolêmica aguda com hidroxietilamido ou ringer lactato em porcos / Pulmonary effects of Acute Normovolemic Hemodilution (ANH) with hydroxyethyl starch and lactated Ringer\'s in pigs

Margarido, Clarita Bandeira 20 September 2005 (has links)
Introdução: A hemodiluição normovolêmica aguda (HNA) é estratégia utilizada para diminuir a necessidade de transfusão em procedimentos cirúrgicos. O hematócrito alvo, a solução empregada e os riscos da HNA são controversos e, embora as ações sobre os sistemas nervoso e cardiocirculatório tenham sido extensamente pesquisados, há poucos estudos sobre implicações pulmonares da HNA. O objetivo deste estudo é avaliar os efeitos pulmonares da HNA comparando amido hidroxietílico e Ringer lactato. Métodos: Vinte e cinco porcos foram monitorizados e cateterizados. Utlizou-se anestesia intravenosa contínua com propofol, cetamina, fentanil e pancurônio. Após estabilização da anestesia, os animais foram randomizados: Grupo Controle (n=8), Grupo HES (amido hidroxietílico, n=7) e Grupo RL (Ringer lactato, n=10). Os animais dos grupos II e III foram submetidos a HNA até hematócrito pré-estabelecido de 15%. A retirada do sangue foi acompanhada da expansão plasmática com amido hidroxietílico ou Ringer lactato na proporção de 1:1 ou 3:1 respectivamente. Medidas de mecânica respiratória e oxigenação sangüínea foram realizadas antes da retirada de sangue (T0), ao término da hemodiluição (T1) e após uma e duas horas (T2 e T3). Ao final foram realizadas biópsias pulmonares. Os dados foram submetidos à análise de variância para medidas repetidas (ANOVA) seguidas pelo teste de Tukey. Resultados: Em relação aos parâmetros do grupo controle, não houve diferença significante durante todo o procedimento. O grupo Ringer lactato demonstrou diminuição da complacência estática e aumento da diferença alvéolo-arterial de O2 (DAa-O2) em relação ao controle (*P<0,05). A análise histopatológica evidenciou atelectasias e alargamento da membrana basal na barreira alvéolo-capilar no grupo Ringer lactato. O grupo amido hidroxietílico apresentou comportamento semelhante ao grupo controle. Conclusões: O estudo sugere que na HNA acentuada, o amido hidroxietílico é superior na preservação estrutural do pulmão, evidenciado pormanter a complacência pulmonar e a oxigenação, quando comparada à realizada com solução de Ringer lactato / Introduction: Acute normovolemic hemodilution (ANH) is a common procedure to decrease the needs of blood transfusion during a variety of surgical procedures. There are controversies regarding ANH such as the target hematocrit, the solution to be used and its risks. Although its effects in heart and brain have been extensively studied; investigations concerning its pulmonary effects are lacking. The aim of this experiment was to compare the pulmonary effects of ANH with hydroxyethyl starch and lactated Ringer\'s. Methods: Twenty five pigs were instrumented for standard hemodynamic monitoring. Intravenous anesthesia consisted continuous infusion of propofol, ketamine, fentanyl and pancuronium. After anesthesia stabilization animals were randomized: Control group (n=8), HES group (hydroxyethyl starch, n=7) and LR group (lactated Ringer\'s, n=10). Animals of Control Group were anesthetized and observed. Group Animals of group HES and LR were submitted to ANH to reach a pre-established hematocrit around 15%. Blood withdrawal was accomplished simultaneously with plasma expansion performed with hydroxyethyl starch (1:1) or with lactated Ringer\'s (3:1). Pulmonary mechanics and oxygen transport and were measured before blood withdrawal (T0), at the end of hemodilution (T1), and one and two hours after the end of the hemodilution (T2, T3). Lungs biopsies were performed at the end. Data were submitted to analysis of Variance for repeated measures followed by the Tukey test. Results: In regard to all parameters of Control group, there were no significant differences during the whole procedure. The LR group demonstrated a decrease in compliance and an increased in (a-A)DO2 (*P<0,05). Hystopathological lung analysis revealed moderate to serious collapses as well as basement membrane enlargement in group LR. The HES data were similar to that found in control group. Conclusion: These results suggest that in severe ANH, HES preserves pulmonary structure and seems to less interfere with pulmonary mechanics and oxygenation indexes when compared to lactated Ringer\'s
119

Efeitos da azatioprina e da transecção brônquica no aparelho mucociliar: estudo experimental em ratos / Effects of azathioprine on the mucociliary system in a model of bronchial transection and reanastomosis in rats

Said, Marcelo Manzano 31 March 2005 (has links)
No laboratório de investigação médica da disciplina de Cirurgia Torácica do Departamento de Cardio-pneumologia da Faculdade de Medicina da Universidade de São Paulo vem sendo desenvolvida uma linha de pesquisa experimental sobre transplante pulmonar, visando elucidar os efeitos que a cirurgia sobre o brônquio e o uso de drogas imunossupressoras têm sobre o aparelho mucociliar. O presente estudo tem por objetivo avaliar os efeitos da azatioprina e da transecção brônquica sobre o aparelho mucociliar em ratos. Utilizamos 36 ratos machos da raça Wistar, não isogênicos, pesando de 200 a 250g, obtidos no biotério da Faculdade de Medicina da Universidade de São Paulo. Todos os animais foram submetidos à anestesia geral, intubação orotraqueal e ventilação mecânica. Em seguida foi realizada uma toracotomia esquerda com transecção e reanastomose do brônquio principal esquerdo. Por fim síntese do tórax e drenagem fechada, que era retirada quando o animal acordava. Os animais foram divididos em dois grupos: com administração de azatioprina e com administração de solução de salina. Eles foram sacrificados aos 7, 15 e 30 dias para retirada dos pulmões e árvore brônquica. O muco foi coletado do brônquio direito e esquerdo. Foi realizada a medida da velocidade do transporte mucociliar à direita e esquerda dos dois grupos e posterior análise das propriedades dos mucos através da medida da velocidade de transporte relativa no palato de rã e da medida do ângulo de contato. As medidas das variáveis dos brônquios direito e esquerdo com e sem azatioprina nos três tempos de avaliação foram submetidas ao teste de Análise de Variância de Duplo Fator. Nos resultados a velocidade do transporte à esquerda foi significativamente reduzida pela transecção brônquica quando comparada entre os grupos: mostrando-se pior aos 30 dias. A velocidade relativa e o ângulo de contato dos mucos coletados à esquerda mostraram com significado estatístico uma piora nas propriedades do muco pela transecção, pricipalmente aos 30 dias. Com a azatioprina e a transecção observamos piora na velocidade do transporte mucociliar significativa ao longo do tempo, maior aos sete dias e com uma progressiva melhora até os 30 dias. O estudo mostrou que a azatioprina não acarretou piora quando associada à transecção. Na presença de azatioprina houve melhora das propriedades do muco, tendo a velocidade do transporte relativo e o ângulo de contato melhora significativa ao longo do tempo. A azatioprina previne uma piora da qualidade do muco. Concluímos que a transecção brônquica piora o transporte mucociliar; a azatioprina preserva as propriedades do muco; a azatioprina piora o transporte até os sete dias; a azatioprina não interage com a transecção para a redução da velocidade do transporte mucociliar e para a piora do muco / At the Experimental Thoracic Surgery Laboratory, Department of Cardio-Pneumology , Department of Pathology, Experimental Air Pollution Laboratory, in the Medical School, São Paulo University, research in lung transplantation, administration of imunossupression drugs and their effects on the mucociliary system are carried out. We develop models of bronchial transeccion and reanastomosis, unilateral lung transplantation, mucociliary transport velocity and mucus transportability in rats, which allow us to observe the resulting alterations. The mechanisms involved in the impairment of the mucociliary function after lung transplantation and immunosuppression therapy are not yet completely understood. The purpose of the present study was to evaluate the effects of azathioprine on the mucociliary system in a model of bronchial transeccion and reanastomosis in rats. We used 36 rats, submitted to general anesthesia, tracheal tube, mechanical ventilation and left thoracotomy, followed by a left main stem bronchus transeccion and reanastomosis. The animals were separated into 2 groups that received or not azathioprine (AZA), and being sacrificed at 7, 15 and 30 days after the surgical procedure. In situ bronchial mucociliary transport (MCT) was determined distal to the anastomosis of the left main stem transected bronchus (LTB) and in the right intact bronchus (RIB). We also studied the surface properties of mucus by using in vitro mucus transportability with a frog palate preparation and mucus contact angle (mucus adhesively) collecting mucus from LTB and RIB. The measures obtained were submitted to statistical analysis. The results showed that the MCT velocity (mm/min) was significantly lower (p<0.01) in the LTB without the AZA administration compared with the RIB with or without AZA. At the LTB with AZA administration there was significant difference (p<0.05) at 7 days compared with the RIB with and without AZA and no significant difference at 15 and 30 days (p>0.05). Mucus in vitro transportability and adhesiveness showed the worst result at the LTB without AZA (p<0.05). In the group that received AZA on 30 days of LTB there was no significantly difference in mucus properties (p>0.05) compared with the RIB groups (with and without AZA). We concluded that AZA led to a temporary marked impairment of MCT, while this occurrence was maintained up to 30 days in the transected bronchus. In addition, AZA contributes to preventing alterations in the mucus surface properties
120

Efeitos pulmonares da hemodiluição normovolêmica aguda com hidroxietilamido ou ringer lactato em porcos / Pulmonary effects of Acute Normovolemic Hemodilution (ANH) with hydroxyethyl starch and lactated Ringer\'s in pigs

Clarita Bandeira Margarido 20 September 2005 (has links)
Introdução: A hemodiluição normovolêmica aguda (HNA) é estratégia utilizada para diminuir a necessidade de transfusão em procedimentos cirúrgicos. O hematócrito alvo, a solução empregada e os riscos da HNA são controversos e, embora as ações sobre os sistemas nervoso e cardiocirculatório tenham sido extensamente pesquisados, há poucos estudos sobre implicações pulmonares da HNA. O objetivo deste estudo é avaliar os efeitos pulmonares da HNA comparando amido hidroxietílico e Ringer lactato. Métodos: Vinte e cinco porcos foram monitorizados e cateterizados. Utlizou-se anestesia intravenosa contínua com propofol, cetamina, fentanil e pancurônio. Após estabilização da anestesia, os animais foram randomizados: Grupo Controle (n=8), Grupo HES (amido hidroxietílico, n=7) e Grupo RL (Ringer lactato, n=10). Os animais dos grupos II e III foram submetidos a HNA até hematócrito pré-estabelecido de 15%. A retirada do sangue foi acompanhada da expansão plasmática com amido hidroxietílico ou Ringer lactato na proporção de 1:1 ou 3:1 respectivamente. Medidas de mecânica respiratória e oxigenação sangüínea foram realizadas antes da retirada de sangue (T0), ao término da hemodiluição (T1) e após uma e duas horas (T2 e T3). Ao final foram realizadas biópsias pulmonares. Os dados foram submetidos à análise de variância para medidas repetidas (ANOVA) seguidas pelo teste de Tukey. Resultados: Em relação aos parâmetros do grupo controle, não houve diferença significante durante todo o procedimento. O grupo Ringer lactato demonstrou diminuição da complacência estática e aumento da diferença alvéolo-arterial de O2 (DAa-O2) em relação ao controle (*P<0,05). A análise histopatológica evidenciou atelectasias e alargamento da membrana basal na barreira alvéolo-capilar no grupo Ringer lactato. O grupo amido hidroxietílico apresentou comportamento semelhante ao grupo controle. Conclusões: O estudo sugere que na HNA acentuada, o amido hidroxietílico é superior na preservação estrutural do pulmão, evidenciado pormanter a complacência pulmonar e a oxigenação, quando comparada à realizada com solução de Ringer lactato / Introduction: Acute normovolemic hemodilution (ANH) is a common procedure to decrease the needs of blood transfusion during a variety of surgical procedures. There are controversies regarding ANH such as the target hematocrit, the solution to be used and its risks. Although its effects in heart and brain have been extensively studied; investigations concerning its pulmonary effects are lacking. The aim of this experiment was to compare the pulmonary effects of ANH with hydroxyethyl starch and lactated Ringer\'s. Methods: Twenty five pigs were instrumented for standard hemodynamic monitoring. Intravenous anesthesia consisted continuous infusion of propofol, ketamine, fentanyl and pancuronium. After anesthesia stabilization animals were randomized: Control group (n=8), HES group (hydroxyethyl starch, n=7) and LR group (lactated Ringer\'s, n=10). Animals of Control Group were anesthetized and observed. Group Animals of group HES and LR were submitted to ANH to reach a pre-established hematocrit around 15%. Blood withdrawal was accomplished simultaneously with plasma expansion performed with hydroxyethyl starch (1:1) or with lactated Ringer\'s (3:1). Pulmonary mechanics and oxygen transport and were measured before blood withdrawal (T0), at the end of hemodilution (T1), and one and two hours after the end of the hemodilution (T2, T3). Lungs biopsies were performed at the end. Data were submitted to analysis of Variance for repeated measures followed by the Tukey test. Results: In regard to all parameters of Control group, there were no significant differences during the whole procedure. The LR group demonstrated a decrease in compliance and an increased in (a-A)DO2 (*P<0,05). Hystopathological lung analysis revealed moderate to serious collapses as well as basement membrane enlargement in group LR. The HES data were similar to that found in control group. Conclusion: These results suggest that in severe ANH, HES preserves pulmonary structure and seems to less interfere with pulmonary mechanics and oxygenation indexes when compared to lactated Ringer\'s

Page generated in 0.6038 seconds