Spelling suggestions: "subject:"solar shading"" "subject:"polar shading""
1 |
Influence of slat-type blinds on energy consumption in office buildingsArcangeli, Gregory Nicholas 30 October 2012 (has links)
Highly glazed facades of commercial buildings are desirable from the point of view of architects, building owners, and building occupants because they create visual connections with the outdoors, offer the possibility for a naturally-lit workplace, and satisfy certain aesthetic desires. The physical properties of glass, however—even when part of the best current window systems—means that this form of environmental separation is highly vulnerable to thermal flux from and to the outdoor environment. The transmission of solar radiation to the perimeter spaces represents an important source of thermal influx, and is typically controlled with shading devices. At best, shading devices create a secondary thermal barrier between indoor and outdoor environments, which can lower energy consumption, decrease peak load, allow for smaller HVAC systems, and provide better occupant comfort. The physical influence of indoor blinds, though, is not always so straightforward. They tend to create two primary effects that operate in opposing directions in regards to energy consumption: (1) they reflect a portion of shortwave solar radiation entering the building back to the outdoors, and (2) they significantly increase the window surface area available for convective heat transfer, which can increase the convective fraction of solar gain, and potentially increase the magnitude of the instantaneous cooling load. For these reasons, the overall impact of interior blinds on equipment load and energy consumption is difficult to foresee. This study describes the results of experiments that tested various configurations of blinds in an outdoor test chamber that simulates conditions in a highly-glazed commercial office building. A simulation model that gives good agreement with experimental results was simultaneously developed. This model will allow retroactive parametric testing of blind parameters for the same given weather and internal load conditions. / text
|
2 |
Fasta och rörliga solskydd : En fallstudie på två skolorEkk, Mustafa, Alsakati, Homam, Matloub, Antouine January 2022 (has links)
Purpose: During the summer, overheating in buildings is becoming more common, but at the same time the passive heat from the sun during the winter can be utilized. This project investigates which solar shading is the best alternative to use in new buildings in Kungsbacka municipality. Method: There are three main aspects that this project focuses on, which are economics, energy and thermal climate. To perform the examination in this project, two rooms in two different schools have been examined with four different solar shading options. The solar shading options are fixed solar shading with a 30 degree inclination, fixed solar shading with 45 degree inclination, variable sun-controlled solar shading, and variable scheduled solar shading. Results: The results of the study shows that variable sun-controlled solar shading provides the best indoor climate from a thermal aspect, and provides the lowest cooling needs as it reduces the amount of passive energy supplied through the window. Variable solar shading is expensive to purchase, maintain and operate. Fixed solar shading types have a cheaper purchase price and have no operation or maintenance costs. Conclusions: you can say that the choice of solar shading types depends on the conditions one has. Given the results from the case studied in this project, variable sun-controlled solar shading type is better than fixed solar shading but more costly. / Överhettning i byggnader blir med tiden alltmer vanligt under sommaren, men däremot vill man kunna utnyttjapassiva värmen från solen under vintertiden. Detta problem väcker intresse för vilka solskydd typer som ger bästa solavskärmning under sommaren och släpper in mest solvärme under vinter. I detta arbete undersöks vilka solskydd som skulle vara bäst att användas i nya byggnader i Kungsbacka kommun. Det finns tre huvudaspekter som detta arbete fokuserar på, och dessa är ekonomi, energi och termiskt klimat.För att utföra undersökningen i arbetet har två rum i två olika skolor undersökts med fyra olika solskyddsalternativ. De olika solskydd typer som har undersökts är, fast solskydd med 30 och 45 graders lutning samt rörliga solstyrda och schemalagda solskydd. Datainsamlingen i arbetet bygger mest på krav från beställare och myndigheter samt mätningar från rummen som har undersökts. För att studera de två fallen utfördes simuleringar i IDA-ICE i form av värde tabeller från modeller som har ritats med samma förutsättningar som rummen har. Resultatet av undersökningen visar att rörligt solstyrt solskydd ger bästa inomhusklimat ur termisk aspekt, samt ger lägsta kylbehov eftersom den minskar den tillförda passiva energimängden genom fönstret. Däremot är rörliga solskydd dyra i inköp, underhåll och drift. Men de har ganska lång livslängd som skulle genom tiden spara på energi om man har aktiv kylning i byggnaden. I detta arbete var termisk komfort utgående punkt för valet av solskydd då aktiv kylning saknades i både skolorna. Fasta solskydd typer är billigare i inköpspriset och har ingen drift eller underhållskostnader, men det visade sig att de inte är lika effektiva som rörliga solskydd typer när det gäller termisk komfort under sommaren. Valet av solskydd beror helt på vad man är intresserad av och ifall man har aktiv kylning eller inte. När det gäller transmissionsförluster genom fönstren vid användning av olika solskydd typer så visade det sig att det blev nästan samma förluster oavsett vilken solskydd typ som används. Det beror helt på själva fönstrets egenskaper som i både fallen var bra. Slutligen kan man säga att valet av solskydd typer beror på förutsättningarna man har. Resultaten från fallet som studerades i detta arbete är att rörliga solskydds typer är bättre än fast solskydd men dyrare. Det finns dock en kostnadsskillnad när det gäller kylning över längre perioder.
|
3 |
Dagsljusdesign för en god visuell miljö / Daylight design for a good visual environmentEnglund, Fanny, Lurell, Emma January 2010 (has links)
During our education to become lighting designers at Jönköping University, the artificial lighting has been in focus. Therefore we wanted to learn more about daylight. We chose to do this from a visual approach in open plan offices. Since daylight is part of the architects´ responsibility to master, we wanted to examine what architects think of when they plan daylight environments in open plan offices and how this is expressed in the buildings with focus on the visual factors. Our questions at issue are: What knowledge do architects have concerning daylight planning, and how do they use this knowledge in their practice? How well do the chosen daylight environments meet the end-users need of a good visual environment? The study consists of three case studies, carried out in the same way. Each case study contains an analysis of the daylight environment in a modern building with open plan offices. A responsible architect was interviewed about the intensions for the building, and about his or her general thoughts about daylight. Three end-users were also interviewed about their experiences of their working environment and the daylight conditions in each building. In total three buildings were analysed, three architects and nine end-users were interviewed. The result shows that it is hard to tell what knowledge architects have about daylight, since it is a part of the overall design of the building. It is also very individual whether the architect displays an interest, and work with daylight issues in an active way. We can see differences in this matter between the interviewed architects. The analysed buildings also show varying results in the visual qualities. The results from our environment analyses are at most part confirmed by the end-users in each building. The problems we have found concerning the daylight environment are primarily the solar shadings and the layout of furnishing. Our conclusion is that architects could benefit from collaboration with lighting designers in daylight issues. This is because lighting designers have more knowledge about the visual conditions of the eye, and a more explicit focus on the end-user. To ensure a good collaboration the lighting designers also need to increase their knowledge about daylight in buildings, and about the building construction as a whole. / Under vår utbildning till ljusdesigners på Jönköpings Tekniska Högskola har fokus legat på det elektriska ljuset. Då vi ville lära oss mer om det minst lika viktiga dagsljuset, valde vi att undersöka detta ur ett visuellt perspektiv i kontorslandskap. Dagsljuset är arkitektens ansvar att behärska, varför vi ville undersöka vad arkitekter tänker på när de planerar dagsljusmiljöer i kontorslandskap, och hur detta yttrar sig i den färdiga byggnaden med fokus på de visuella faktorerna. Följande frågeställningar formulerades: Vilken kunskap har arkitekter om dagsljusplanering och hur använder de sig av denna kunskap i praktiken? Hur väl uppfyller utvalda dagsljusmiljöer brukarens behov av en god visuell miljö? Studien bygger på tre fallstudier utförda på samma sätt. Varje fallstudie innefattar en analys av dagsljusmiljön i en modern byggnad innehållande kontorslandskap. En ansvarig arkitekt intervjuades om intentionerna med respektive byggnad, samt om dennes tankar kring dagsljus i allmänhet. I respektive byggnad intervjuades även tre brukare om deras upplevelse av arbetsmiljön och dagsljuset. Totalt analyserades tre byggnader, och tre arkitekter samt nio brukare intervjuades. Resultatet visar att det är svårt att uttala sig om arkitekters kunskap om dagsljus, då det ingår som en del i gestaltningen av hela byggnaden. Det är även väldigt individuellt huruvida arkitekten intresserar sig för och aktivt arbetar med dagsljusfrågor. Vi ser stora skillnader i det avseendet hos de arkitekter vi intervjuade. De analyserade byggnaderna visar även skiftande resultat i dagsljusmiljöns visuella kvaliteter. Resultatet av våra miljöanalyser bekräftas till stor del av brukarna i respektive byggnad. Problemområden för den visuella dagsljusmiljön som vi fann, är i första hand solavskärmningar samt möblering i rummet. Vår slutsats är att arkitekter kan ha nytta av att samarbeta med ljusdesigners i dagsljusfrågor då ljusdesigners har en större kunskap om ögats visuella förutsättningar och ett tydligare brukarperspektiv. För att ett gott samarbete ska kunna upprättas krävs samtidigt att ljusdesigners ökar sin kunskap om dagsljus i byggnader, och om byggnaders konstruktion som helhet.
|
4 |
Dagsljusdesign för en god visuell miljö / Daylight design for a good visual environmentEnglund, Fanny, Lurell, Emma January 2010 (has links)
<p>During our education to become lighting designers at Jönköping University, the artificial lighting has been in focus. Therefore we wanted to learn more about daylight. We chose to do this from a visual approach in open plan offices. Since daylight is part of the architects´ responsibility to master, we wanted to examine what architects think of when they plan daylight environments in open plan offices and how this is expressed in the buildings with focus on the visual factors.</p><p>Our questions at issue are:</p><ol><li>What knowledge do architects have concerning daylight planning, and how do they use this knowledge in their practice?</li><li>How well do the chosen daylight environments meet the end-users need of a good visual environment? </li></ol><p>The study consists of three case studies, carried out in the same way. Each case study contains an analysis of the daylight environment in a modern building with open plan offices. A responsible architect was interviewed about the intensions for the building, and about his or her general thoughts about daylight. Three end-users were also interviewed about their experiences of their working environment and the daylight conditions in each building. In total three buildings were analysed, three architects and nine end-users were interviewed.</p><p>The result shows that it is hard to tell what knowledge architects have about daylight, since it is a part of the overall design of the building. It is also very individual whether the architect displays an interest, and work with daylight issues in an active way. We can see differences in this matter between the interviewed architects.</p><p>The analysed buildings also show varying results in the visual qualities. The results from our environment analyses are at most part confirmed by the end-users in each building. The problems we have found concerning the daylight environment are primarily the solar shadings and the layout of furnishing.</p><p>Our conclusion is that architects could benefit from collaboration with lighting designers in daylight issues. This is because lighting designers have more knowledge about the visual conditions of the eye, and a more explicit focus on the end-user. To ensure a good collaboration the lighting designers also need to increase their knowledge about daylight in buildings, and about the building construction as a whole.</p> / <p>Under vår utbildning till ljusdesigners på Jönköpings Tekniska Högskola har fokus legat på det elektriska ljuset. Då vi ville lära oss mer om det minst lika viktiga dagsljuset, valde vi att undersöka detta ur ett visuellt perspektiv i kontorslandskap. Dagsljuset är arkitektens ansvar att behärska, varför vi ville undersöka vad arkitekter tänker på när de planerar dagsljusmiljöer i kontorslandskap, och hur detta yttrar sig i den färdiga byggnaden med fokus på de visuella faktorerna.</p><p>Följande frågeställningar formulerades:</p><ol><li>Vilken kunskap har arkitekter om dagsljusplanering och hur använder de sig av denna kunskap i praktiken?</li><li>Hur väl uppfyller utvalda dagsljusmiljöer brukarens behov av en god visuell miljö?</li></ol><p>Studien bygger på tre fallstudier utförda på samma sätt. Varje fallstudie innefattar en analys av dagsljusmiljön i en modern byggnad innehållande kontorslandskap. En ansvarig arkitekt intervjuades om intentionerna med respektive byggnad, samt om dennes tankar kring dagsljus i allmänhet. I respektive byggnad intervjuades även tre brukare om deras upplevelse av arbetsmiljön och dagsljuset. Totalt analyserades tre byggnader, och tre arkitekter samt nio brukare intervjuades.</p><p>Resultatet visar att det är svårt att uttala sig om arkitekters kunskap om dagsljus, då det ingår som en del i gestaltningen av hela byggnaden. Det är även väldigt individuellt huruvida arkitekten intresserar sig för och aktivt arbetar med dagsljusfrågor. Vi ser stora skillnader i det avseendet hos de arkitekter vi intervjuade.</p><p>De analyserade byggnaderna visar även skiftande resultat i dagsljusmiljöns visuella kvaliteter. Resultatet av våra miljöanalyser bekräftas till stor del av brukarna i respektive byggnad. Problemområden för den visuella dagsljusmiljön som vi fann, är i första hand solavskärmningar samt möblering i rummet.</p><p>Vår slutsats är att arkitekter kan ha nytta av att samarbeta med ljusdesigners i dagsljusfrågor då ljusdesigners har en större kunskap om ögats visuella förutsättningar och ett tydligare brukarperspektiv. För att ett gott samarbete ska kunna upprättas krävs samtidigt att ljusdesigners ökar sin kunskap om dagsljus i byggnader, och om byggnaders konstruktion som helhet.</p>
|
5 |
Simplified Methodology for Designing Parabolic Trough Solar Power PlantsVasquez Padilla, Ricardo 01 January 2011 (has links)
The performance of parabolic trough based solar power plants over the last 25 years has proven that this technology is an excellent alternative for the commercial power industry. Compared to conventional power plants, parabolic trough solar power plants produce significantly lower levels of carbon dioxide, although additional research is required to bring the cost of concentrator solar plants to a competitive level. The cost reduction is focused on three areas: thermodynamic efficiency improvements by research and development, scaling up of the unit size, and mass production of the equipment. The optimum design, performance simulation and cost analysis of the parabolic trough solar plants are essential for the successful implementation of this technology. A detailed solar power plant simulation and analysis of its components is needed for the design of parabolic trough solar systems which is the subject of this research.
Preliminary analysis was carried out by complex models of the solar field components. These components were then integrated into the system whose performance is simulated to emulate real operating conditions. Sensitivity analysis was conducted to get the optimum conditions and minimum levelized cost of electricity (LCOE). A simplified methodology was then developed based on correlations obtained from the detailed component simulations.
A comprehensive numerical simulation of a parabolic trough solar power plant was developed, focusing primarily on obtaining a preliminary optimum design through the simplified methodology developed in this research. The proposed methodology is used to obtain optimum parameters and conditions such as: solar field size, operating conditions, parasitic losses, initial investment and LCOE. The methodology is also used to evaluate different scenarios and conditions of operation.
The new methodology was implemented for a 50 MWe parabolic trough solar power plant for two cities: Tampa and Daggett. The results obtained for the proposed methodology were compared to another physical model (System Advisor Model, SAM) and a good agreement was achieved, thus showing that this methodology is suitable for any location.
|
6 |
Dispositivos de proteção solar e eficiência energética em edifícios de escritório : uma avaliação para a cidade de Maceió/AL. / Solar shading devices and office buildings energy efficiency : an evaluation for Maceió city, Brazil.Martins, Thiago Luiz de Oliveira Gomes 07 December 2007 (has links)
Since the oil energy crisis of the seventies until the Brazilian 2001 blackout, energy savings
became an important issue in Brazil and the building industry has been identified as a sector
where substantial savings may occur. In commercial buildings the energy consumption is
strongly related to air conditioning systems. Facing this context, the present work intends to
evaluate the impact of using solar shading devices in the energy consumption performance of
medium size typical office buildings located in Maceió city, Brazil. In low latitude regions,
solar radiation represents an important parcel of buildings total heat gain. The evaluation was
carried out through a parametric investigation where the effect of facades orientation and
typology in the energy consumption, as well as the effect of plan typology regarding the
location of corridor (central or lateral). Computer simulations of models representing the
combinations for parameters above mentioned were carried out using the Energyplus software
in order to estimate the energy consumption of each model. The simulations have shown the
energy consumption for the considered models, allowing for the estimation of the impact
magnitude regarding each of the different examined parameters. When solar shading devices
were added to facades built in masonry with exposed windows the energy savings related to
air conditioning systems was 18.7%, while for curtain wall facades it reached 39.2%. Results
lead to the conclusion that the use of solar shading devices represents a relevant design
strategy for energy savings in office buildings located in Maceió. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Desde a crise do petróleo nos anos de 1970 até o colapso energético de 2001 a conservação de
energia passou a ser alvo de discussões no Brasil e o setor da construção civil foi identificado
como um campo de grande potencial de combate ao desperdício energético. Nas edificações
comerciais o consumo energético está fortemente relacionado aos sistemas artificiais de
geração de conforto ambiental como os sistemas artificiais de condicionamento térmico, por
exemplo. Diante deste contexto, o presente trabalho avalia o impacto decorrente da utilização
dos dispositivos de proteção solar para o desempenho energético de edificações que
representam as características típicas dos edifícios de escritórios de médio porte localizados
na cidade de Maceió/AL. Sabe-se que nestas regiões, de baixa latitude, a radiação solar
representa uma parcela significativa no calor total que atinge as edificações. Para tal, adotouse
uma metodologia de análises paramétricas nas quais foi comparado o desempenho
energético das edificações sob diversas condições de orientação geográfica, tipologia de
fechamento de fachada e localização do corredor de circulação horizontal (central e lateral).
Os índices de consumo energético foram obtidos a partir de simulações com modelos
computacionais utilizando o software Energyplus. As simulações realizadas permitiram
quantificar e classificar o desempenho energético das edificações, sob as diversas
características construtivas estudadas. A inclusão dos dispositivos de proteção solar
representou, em alguns casos, para os sistemas artificiais de condicionamento térmico,
economia energética anual de 18,7% no comparativo com as edificações com fachada em
alvenaria e janela exposta e, 39,2% no comparativo com edificação com fechamento de
fachada em pele de vidro. Desta forma conclui-se que a utilização dos dispositivos de
proteção solar apresenta-se como uma alternativa de adequação climática e de redução de
consumo energético bastante eficiente para edificações localizadas na cidade de Maceió.
|
7 |
Val av solavskärmning : Simuleringar för att identifiera lämplig solavskärmning för kontorshuset VråkenBerglund, Max January 2023 (has links)
The office building Vråken located in Västerås, Sweden, is soon to be renovated and improved solar shading is considered. In this project, five types of solar shading (zip screens, awnings, window film, built-in venetian blinds and roller blinds) were studied to find out their impact on the building's solar gain, cooling load and thermal comfort. The results were analysed to propose sufficient solar shading. In the early stages of the project a questionnaire was distributed to workers in Vråken with the purpose of finding out their opinions about the thermal comfort in the building. A model of 24 selected rooms in the building was also created in IDA ICE to simulate the five different types of solar shading and compare them to a scenario without any solar shading. The questionnaire was used to calculate PPD, showing that 39,3% of the workers were dissatisfied with the thermal comfort during the summer. The simulations in IDA ICE revealed that, overall, zip screens produced the best results. This was followed by awnings, built-in venetian blinds, window film and roller blinds in that order. Awnings resulted in the smallest solar gain, 62% smaller than without solar shading, while roller blinds resulted in the biggest solar gain, 31% smaller than without solar shading. The cooling load was reduced the most with zip screens (-43%) and the least with roller blinds (-14%) compared to the scenario without solar shading. Operative temperatures were also simulated. Once again zip screens produced the best results and roller blinds the worst. By analysing the results from the questionnaire and the simulations, different solar shading applications were proposed for different parts of the building. For the façade facing south, zip screens combined with a new window film was suggested. For the façade facing north the recommendation was built-in venetian blinds, and facing east and west, zip screens combined with either roller blinds or built-in venetian blinds was suggested. / Energieffektivisering av byggnader är ett tidsenligt och angeläget område. Solen utgör här en viktig roll som naturlig energikälla genom instrålning i byggnader. Under eldningssäsongen är detta välkommet, men under sommaren kan inverkan vara kontraproduktiv med övertemperaturer och ökade kylbehov som resultat. I ett försök att minimera de oönskade konsekvenserna sommartid har i detta arbete fem solavskärmningar (markis, zip screen, persienner, rullgardin och solfilm) undersökts för kontorshuset Vråken i Västerås. Fokusområdet omfattar parametrarna solvärmelast, kyleffektbehov och termisk komfort och har legat till grund för förslag på tillämpning av förbättrad solavskärmning för byggnaden. Arbetet inleddes med en enkätundersökning som delades ut till arbetare i Vråken. Denna syftade till att undersöka den aktuella upplevelsen av inomhusklimatet relaterat till solstrålning och solavskärmning i byggnaden. Huvudmetoden i arbetet var annars modellering och simulering av byggnaden i IDA ICE. 24 utvalda kontorsrum i Vråken byggdes upp med programvaran och utrustades med de beaktade solavskärmningarna i olika fall. Fallen simulerades därpå för att erhålla resultat för de studerade parametrarna. Enkätundersökningen användes för beräkningar av verkligt PPD, ett mått på missnöje beträffande inomhusklimatet. Resultatet visade att 39,3% av arbetarna var missnöjda sommartid. Enkätsvaren indikerade problem med övertemperaturer och värme från solstrålningen, i synnerhet i byggnadens söderläge. Simuleringsresultaten visade att solavskärmning i hög grad minskar såväl solvärmelasten och kyleffektbehovet som den operativa temperaturen i Vråken. Av de beaktade solavskärmningarna var solvärmelasten för byggnaden lägst med markiser (62% lägre än utan solavskärmning) och högst med rullgardiner (- 31%). Solvärmelasten jämfördes mot Miljöbyggnads betygssystem Brons, Silver och Guld. Kyleffekten minskade mest med zip screens (-43%) och minst med rullgardiner (-14%) i jämförelse med fallet utan solavskärmning. För den operativa temperaturen undersöktes både den maximala operativa temperaturen under året och antalet timmar då den överstiger 24°C. Återigen visades på bäst resultat för zip screens och sämst för rullgardiner. Överlag presterade zip screens bäst, följt av markiser, persienner, solfilm och rullgardiner i den ordningen. Vissa variationer fanns mellan byggnadens olika delar (syd-, öst-, väst- och norrläge). Utifrån arbetets simuleringsresultat och enkätundersökning gavs förslag på ny tillämpning av solavskärmning för Vråken. För sydsidan föreslogs zip screens och ny solfilm. På norrsidan var behovet av solavskärmning inte lika stort, men persienner är här en bra lösning. Öst-och västsidan skulle precis som sydsidan nå fördelar genom utvändig solavskärmning. Även här föreslogs zip screens och antingen rullgardiner eller persienner. Alternativa ekonomialternativ presenterades också där det var relevant.
|
8 |
Investigating The Relationship Between Mean Radiant Temperature (MRT) And Predicted Mean Vote (PMV) : A case study in a University buildingGodbole, Swapnil January 2018 (has links)
Thermal comfort in an indoor environment is largely dependent on the four environmental and two personal parameters which is most commonly measured by the Predicted Mean Vote (PMV) model developed by Fanger. It has been studied that variations in these parameters beyond a range could lead to discomfort complaints. However, little research has been done on the effect of mean radiant temperature variations and its influence on predicted mean vote and thermal comfort specially in an actual building environment. This study aims to investigate the relationship between mean radiant temperature and predicted mean vote in indoor environment. Using the methods of on-site measurement of indoor environmental parameters and subjective votes on thermal sensation in an educational building; it was found that rise in mean radiant temperature lead to rise in PMV value and discomfort vote amongst occupants seated near glazed façade. A very strong positive correlation was found between mean radiant temperature and PMV near the window side of the room under warm and sunny weather conditions. Analysis of indoor environmental data from the several measurement sessions concluded that rise in mean radiant temperature and PMV was not noticed until there was a direct solar transmission through the window. It is advisable to use solar shading on windows, but special consideration should be given to the trade-offs between energy consumption (heating or cooling) and lighting energy consumption. No conclusions could be made in terms of ankle draft discomfort due to experimental limitations and more research would be required to investigate this phenomenon. / Termisk komfort inomhusmiljö är till stor del beroende av de fyra miljö och två personlig parametrar som oftast mäts av Predicted Mean Vote (PMV) modell som utvecklats av Fanger. Det har studerats att variationer i dessa parametrar utanför en limit kan leda till missnöjeklagomål. Däremot har lite forskning gjorts på effekten av mean radiant tempratur och dess inverkan på predicted mean vote och termisk komfort speciellt i en verklig byggnadsmiljö. Syftet med denna studie är att undersöka sambandet mellan mean radiant tempratur och predicted mean vote i inomhusmiljö. Användning mätmetoderna av inomhusmiljöparametrar och subjektiva röster av termisk komfort uppfattning i en byggnad för utbildning; det konstaterades att stiga i medel leda mean radiant tempratur att stiga i predicted mean vote värde och missnöje rösta bland byggnad brukarna sitter nära glasfasaden. En väldigt positiv korrelation mellan men radiant tempratur och predicted mean vote nära en fönstersida under varma och soliga väder var noterat. Genom att analysera data av inomhusmiljön från de multipla mätningssessionerna konkluderat att ökningen i mean radiant tempratur och predicted mean vote inte märktes tills det fanns en direkt soltransmission genom fönstret. Det är rekommenderar att använda solskydd på fönster, men med tanke på kompromisser mellan energiförbrukning (värme eller kyla) och ljussättning konsumtion. Inga slutsatser kan göras om luftdrag på fotled grund av experimentella begränsningar och mer forskning skulle krävas för att undersöka detta fenomen.
|
9 |
Komfort- och energianalys vid installation av markiser på Högskolans i Gävle glasfasader : Mätningar och IDA ICE-simuleringarHöglund, Marcus, Stenås, Anton January 2021 (has links)
Högskolan i Gävle planerar att installera solavskärmande markiser på entréhallarnas sydliga glasade fasader. Sedan uppbyggnad har entrébyggnaden som inkluderar ”Rävhallen” och ”Fårhallen” lidit av bristfällig termisk inomhuskomfort på grund av värmeläckage och överhettning orsakade av fasadernas fönsterpartier. Detta examensarbete gjordes i syfte att via mätningar undersöka den termiska inomhuskomforten i Högskolans i Gävle entréhallar. Arbetet syftade också till att årssimulera och analysera årlig energiförbrukning och termisk inomhuskomfort innan och efter installationen av solavskärmande markiser på byggnadens glasfasader, i simuleringsprogrammet IDA ICE. En komfortundersökning gjordes genom att mäta termisk komfort och inomhustemperaruter under två tillfällen i april månad. Mätningarna gjordes under en molnig dag och en solig dag vid samma utomhustemperatur, för att undersöka solinstrålningens inverkan på byggnadens termiska komfort och inomhustemperaturer. Komfortundersökningen visade att den termiska komforten i Rävhallen och Fårhallen var undermålig då överhettning uppstår vid hög solinstrålning. Nödvändiga data inför modellering och simulering insamlades genom observationer, uppskattning, beräkningar och samtal med drifttekniker vid Akademiska hus. Efter datainsamlingen konstruerades en modell i simuleringsprogrammet IDA ICE. Innan simulering validerades modellen med hjälp av tidigare uppmätta temperaturer under april månad. Sedan simulerades byggnadens energiförbrukning och termiska inomhuskomfort över ett helt år, utan markiser, och därefter med markiser. Resultatet visade att den termiska komforten förbättrades markant vid installation av markiser. Höga topptemperaturer som tidigare förekom i byggnaden minskade eftersom markiserna reducerade solinstrålningen genom fasadens fönsterpartier. Det totala årliga energibehovet ökade dock från 605 MWh till 635 MWh. Det årliga energibehovet för kyla minskade något från 3,4 MWh till 3,2 MWh. Att energiförbrukningen ökade berodde på att markiserna reducerade nyttig gratisvärme från solinstrålningen, särskilt under uppvärmningssäsong. För vidare forskning föreslås en mer effektiv styrteknik av markiserna och en mer detaljrik simuleringsmodell för att få tillförlitligare resultat. Vid tillämpning av bättre anpassad styrning av markiserna bedöms energibesparingspotentialen bli större. Slutsatsen drogs att markiser kan förbättra den termiska inomhuskomforten avsevärt, men att energiförbrukningen kan komma att öka beroende på styrteknik. / The University of Gävle plans to install solar shading awnings on the southern glass facades of the main entrances. Since construction, the main entrances Rävhallen and Fårhallen have suffered from poor thermal indoor comfort due to heat leakage and overheating due to the windows on the facades. This thesis was done in order to map and investigate the thermal indoor comfort in the University of Gävle's main entrances. The work also aimed to simulate and analyze annual energy consumption and thermal indoor comfort before and after the installation of solar shading awnings on the building's glass facades, in the simulation program IDA ICE. A comfort survey was conducted by measuring thermal comfort and indoor temperature ranges on two occasions in April. The measurements were made during a cloudy day and a sunny day at the same outdoor temperature, to investigate the effect of solar radiation on the building's thermal comfort and indoor temperatures. The comfort survey showed that the thermal comfort in Rävhallen and Fårhallen was insufficient as overheating occurs at high solar radiation. Data necessary for modeling and simulation was collected through observations, estimates, and dialogs with operating technicians from Akademiska hus. After data collection, a model was constructed in the simulation program IDA ICE. Before simulation, the model was validated using previously measured temperatures during the month of April. Then the building's energy consumption and thermal indoor comfort were simulated over a whole year, without awnings, and with awnings. The results showed that the thermal comfort was significantly improved by the awnings installations. High peak temperatures that previously occurred in the building decreased because of the reduced solar radiation through the glass facade. The total annual energy demand increased from 605 MWh to 635 MWh. However, the annual energy demand for cooling decreased from 3,4 MWh to 3,2 MWh. The increase in energy consumption was due to the awnings reducing useful heat from solar radiation, especially during the heating season. Prior to further research, a more efficient control technique of the awnings and a more detailed model to improve the simulation results are proposed. When applying better adapted control of the awnings, the energy saving potential is considered to be greater. It was concluded that awnings can significantly improve indoor thermal comfort, but that energy consumption may increase depending on control technology.
|
10 |
Utformningens betydelse för energiförbrukningen : En fallstudie av verksamhetsbyggnader / Design's impact on energy consumption : A case study of business buildingsRitz, Carolina, Mattsson-Mårn, Malin January 2015 (has links)
Purpose: The building sector accounts for 40 % of the total energy consumption in Sweden today, and the largest proportion is consumed during the operating phase. From the year 2020 and onwards, all new buildings should be erected as zero-emissionbuildings. The building’s design can reduce energy demands, but the current legal requirements do not favour energy-efficient designs. This study focuses on the design’s importance for the energy efficiency of buildings, i.e., energy-saving design. The impact of specific measures is difficult to calculate due to the complexity of reality. This study aims to highlight the measures that could reduce energy consumption in commercial buildings. Method: In order to provide answers to the issues stated in the report and to achieve the objective of the study, case studies are being conducted investigating three commercial buildings where deliberate decisions were made to use energy-reducing measures. Results and conclusions are based on qualitative interviews and literature studies. Findings: The energy-reducing design measures found to be of most importance used in the studied buildings are the form factor, the window portion and the thermal storage capacity. Moreover, significant savings are possible by carefully consider how solar energy can be limited or used in the building. Generally, buildings tends to become more technical, therefore technical knowledge early in the process is important to reach a good result. Economic incentives and clear objectives with right focus are also important for optimizing a building’s energy performance. The wording and the requirement levels in the Swedish building regulations highly controls the construction of energy efficient buildings. Implications: This study shows how energy efficient design is made today and provides an indication of what can be done and what should be prioritized. By imposing requirements on consumed energy instead of bought, energy efficient design could be favoured. Furthermore, this study suggests that a balance between windows, façade and solar shading are important energy-reducing measures. Regardless of selected energyreducing measures, a good performance is essential. Finally, this study shows that a methodical use of existing knowledge and technology makes a difference. Limitations: A lifecycle approach provides an overall picture of a building’s energy consumption. However, this study is based on the energy consumption during the operating phase. The result of this study does not take economic or aesthetic factors into account. This study is a comparative case study and is based on few but carefully matched cases. The selected cases are commercial buildings where deliberate decisions were made to use energy-reducing measures.
|
Page generated in 0.0675 seconds