• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 468
  • 87
  • 74
  • 64
  • 48
  • 39
  • 16
  • 10
  • 8
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • Tagged with
  • 1000
  • 131
  • 84
  • 80
  • 76
  • 71
  • 66
  • 65
  • 64
  • 63
  • 59
  • 58
  • 54
  • 51
  • 48
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Study of serpentine acceleration in zero-chromatic FFAG accelerators / 零色収差FFAG加速器における蛇行加速に関する研究

Yamakawa, Emi 25 March 2013 (has links)
Kyoto University (京都大学) / 0048 / 新制・課程博士 / 博士(工学) / 甲第17563号 / 工博第3722号 / 新制||工||1567(附属図書館) / 30329 / 京都大学大学院工学研究科原子核工学専攻 / (主査)教授 森 義治, 教授 伊藤 秋男, 教授 中島 健 / 学位規則第4条第1項該当
412

Measurement of bone exercise:osteogenic features of loading

Ahola, R. (Riikka) 12 October 2010 (has links)
Abstract It is known that exercise strengthens bone and can prevent bone loss. However, the optimal amount and intensity of exercise beneficial to bones is not known, because there have been no long-term methods to evaluate the osteogenic features of exercise. The aim of the study was to reveal the determinants of physical activity or exercise beneficial for the bone, using novel accelerometer-based measurement of bone loading. Additionally, the study tested the applicability of a previously developed bone exercise regimen in Japanese women, using the same measurement technology. Acceleration data obtained in two exercise trials were analyzed. The subjects were healthy women aged 25–50 years who participated in 12-month high-impact exercise trials either in Finland or in Japan. The individual daily bone loading was assessed with a waist-worn accelerometer-based bone exercise recorder. Vertical acceleration peaks caused by impacts on the ground were recorded. Different key characteristics of the acceleration peaks were analyzed. A Daily Impact Score was developed to describe individual daily osteogenic loading. Bone mineral density was measured with dual x-ray absorptiometry at the proximal femur and lumbar spine, and cross-sectional geometry of mid-femur was assessed with spiral computed tomography. Calcaneus was assessed with quantitative ultrasound. Bone changes were analyzed with respect to the acceleration data. The results showed that the number of impacts during the first six months of exercise was associated with the 12-month bone changes at the hip and mid-femur. The slope, area and energy of the acceleration signal were significant determinants of bone density changes. The threshold of acceleration slope for improving bone mineral density at the hip was 100 g/s, which can be achieved during exercise including fast movements such as running and jumping. Daily Impact Score was able to describe the osteogenic potential of daily mechanical loading with a single score. The results also showed that bone exercise can be applied to Japanese premenopausal women. A brief high-impact exercise program with 50 jumps prevented bone loss at the femoral neck. The study gives new information on the measurement of bone-specific exercise. This information can be used in designing new feasible training programs for women to prevent osteoporosis and fracture risk factors. / Tiivistelmä Liikunta vahvistaa luustoa ja voi ehkäistä luukatoa. Luuston kannalta tehokkaimman liikunnan tarkkaa määrää ja laatua ei ole tiedetty, koska sen mittaamiseen ei ole ollut soveltuvaa menetelmää. Tutkimuksen tavoitteena oli selvittää, mitkä ryhmässä aiemmin kehitetyn luuliikuntaohjelman piirteet ovat tärkeimpiä luun vahvistumisen kannalta. Luuston kuormituksen mittaamiseen käytettiin uutta kiihtyvyysanturiin pohjautuvaa menetelmää eli luuliikuntamittaria. Samaa mittausmenetelmää käyttäen selvitettiin, onko luuliikuntaohjelma tehokas ja sovellettavissa myös japanilaisille naisille. Tutkittavat olivat 25–50 -vuotiaita naisia, jotka osallistuivat vuoden mittaiseen hyppyjä sisältävään liikuntaharjoitteluun Suomessa tai Japanissa. Naiset pitivät päivittäin vyötäröllään luuliikuntamittaria, jonka mittaamista kiihtyvyyspiikeistä eli impakteista analysoitiin kuormitusta kuvaavia piirteitä. Kerätyn kiihtyvyystiedon avulla kehitettiin myös uusi kuormitusindeksi kuvaamaan henkilön päivittäistä luustoon kohdistuvaa kuormitusta. Reisiluun yläosan ja lannerangan mineraalitiheyden muutos mitattiin kaksienergisellä röntgenlaitteella ja reisiluun varren poikkileikkauksen geometrian muutos määritettiin tietokonetomografialla. Kantaluun ominaisuuksien muutos mitattiin kvantitatiivisella ultraäänellä. Luustomuutoksia verrattiin mitattuun kuormitustietoon. Tulokset osoittivat, että korkeiden impaktien määrä harjoittelun kuuden ensimmäisen kuukauden aikana oli yhteydessä luun mineraalitiheyden ja geometrian myönteisiin muutoksiin. Kiihtyvyyspiikin kulmakerroin, pinta-ala ja energia olivat yhteydessä luustomuutokseen. Kiihtyvyyden kulmakertoimen kynnysarvo luuntiheyden paranemiseen lonkassa oli 100 g/s, joka voidaan saavuttaa nopeita liikkeitä sisältävässä liikunnassa, kuten juoksussa ja hypyissä. Päivittäinen kuormitusindeksi oli yhteydessä positiivisiin muutoksiin luuntiheydessä hyppyharjoitteluun osallistuneilla. Lisäksi tutkimuksen tulokset osoittivat, että luuliikuntaohjelma soveltuu myös japanilaisten naisten osteoporoosin ehkäisyyn. Lyhyt luuliikuntaohjelma, joka suoritettiin työpaikalla taukojen aikana kolmesti viikossa, ehkäisi reisiluun kaulan luukatoa japanilaisilla, premenopausaalisilla naisilla. Tutkimus antaa uutta tietoa luuliikunnan mittaamisesta ja tuloksia voidaan käyttää suunniteltaessa liikuntaohjeistuksia osteoporoosin ja murtumien riskitekijöiden ehkäisyyn.
413

STOMKONSTRUKTIONER FÖR HÖGA HUS : Struktur och utformning av stabiliserande element

Gullers, Johan, Imberg, Tobias January 2017 (has links)
No description available.
414

Particle Acceleration in Two Converging Shocks

Wang, Xin, Giacalone, Joe, Yan, Yihua, Ding, Mingde, Wang, Na, Shan, Hao 15 June 2017 (has links)
Observations by spacecraft such as ACE, STEREO, and others show that there are proton spectral "breaks" with energy E-br at 1-10 MeV in some large CME-driven shocks. Generally, a single shock with the diffusive acceleration mechanism would not predict the "broken" energy spectrum. The present paper focuses on two converging shocks to identify this energy spectral feature. In this case, the converging shocks comprise one forward CME-driven shock on 2006 December 13 and another backward Earth bow shock. We simulate the detailed particle acceleration processes in the region of the converging shocks using the Monte Carlo method. As a result, we not only obtain an extended energy spectrum with an energy "tail" up to a few 10 MeV higher than that in previous single shock model, but also we find an energy spectral "break" occurring on similar to 5.5 MeV. The predicted energy spectral shape is consistent with observations from multiple spacecraft. The spectral "break," then, in this case is caused by the interaction between the CME shock and Earth's bow shock, and otherwise would not be present if Earth were not in the path of the CME.
415

Dosimetrische Charakterisierung laserbeschleunigter Teilchenstrahlen für in vitro Zellbestrahlungen / Dosimetric characterization of laser-accelerated particle beams for in vitro cell irradiations

Richter, Christian 24 July 2017 (has links) (PDF)
Die Anwendung von Hochintensitätslasern zur Beschleunigung von Teilchen bietet eine Alternative zu klassischen Teilchenbeschleunigern und den von diesen erzeugten Strahlenqualitäten. Nach großen Fortschritten auf dem Gebiet der Laser-Teilchenbeschleunigung wurde die Anwendung der neuen Technologie in der klinischen Ionentherapie vorgeschlagen und diskutiert. Bevor es dazu kommen kann, muss aber neben der Verbesserung der Strahleigenschaften, wie z. B. der Erhöhung der Energie, und der Stabilität der Teilchenbeschleunigung auch eine geeignete physikalische und dosimetrische Charakterisierung entwickelt und die biologische Wirksamkeit dieser neuartigen, ultrakurz gepulsten Strahlenqualität mit extrem hoher Pulsdosisleistung untersucht werden. Dies erfordert eine ganze Reihe von umfangreichen Experimenten der notwendigen Translationskette, angefangen von in vitro Zellbestrahlungen über in vivo Studien bis hin zu präklinischen Untersuchungen und ersten klinischen Studien. Hierzu wurden das Verbundprojekt onCOOPtics gegründet und in einem ersten Schritt in vitro Zellbestrahlungen zur Untersuchung der biologischen Wirksamkeit laserbeschleunigter Teilchen durchgeführt. Dazu wurden Dosis-Effekt-Kurven für humane Tumor- und Normalgewebs-Zelllinien jeweils für mehrere biologische Endpunkte bestimmt. Begonnen wurde dabei mit der umfangreichen Untersuchung laserbeschleunigter Elektronen am JeTi-Lasersystem in Jena, auf welche zum Zeitpunkt der Verfügbarkeit des DRACO-Lasersystems in Dresden die dosimetrische und strahlenbiologische Charakterisierung laserbeschleunigter Protonen an diesem Lasersystem folgte. Dabei stellte die Entwicklung einer präzisen Dosimetrie zur Bestimmung der applizierten Dosis aufgrund der Strahleigenschaften laserbeschleunigter Teilchen eine große Herausforderung dar. Sie ist aber sowohl im Hinblick auf eine spätere klinische Anwendung als auch für die Durchführung quantitativer strahlenbiologischer Experimente obligatorisch. Diese Arbeit, die im Rahmen des Verbundprojektes entstanden ist, leistet dazu in vielfacher Hinsicht einen wesentlichen Beitrag: Erstens wurden geeignete Detektoren zur präzisen dosimetrischen Charakterisierung laserbeschleunigter Elektronen und Protonen entwickelt, optimiert und charakterisiert sowie präzise kalibriert. So wurden umfangreiche Studien zu verschiedenen Eigenschaften der auch in der klinischen Dosimetrie angewandten radiochromischen Filme durchgeführt und die Filme entsprechend kalibriert. Dabei wurden neue Erkenntnisse u. a. über deren Energieabhängigkeit gewonnen, die für zahlreiche Anwendungen der Filme von Bedeutung sind. Weiterhin wurden verschiedene Ionisationskammern zur Echtzeit-Strahlmonitorierung von laserbeschleunigten Elektronen und Protonen ausgewählt und dosimetrisch charakterisiert. Zudem wurde der Einsatz von CR-39 Festkörperspurdetektoren zur spektroskopischen Untersuchung laserbeschleunigter Protonen etabliert, indem die Nachverarbeitung und Auslesung der Detektoren charakterisiert und optimiert wurden und außerdem eine retrospektive Filterprozedur der detektierten Krater entwickelt und angewendet wurde. Ferner wurde ein Faraday Cup, der auf die speziellen Eigenschaften derzeitiger laserbeschleunigter Protonen-Strahlenqualitäten abgestimmt ist, entwickelt, charakterisiert und mit drei voneinander unabhängigen Methoden kalibriert. Die radiochromischen Filme und der Faraday Cup konnten daraufhin als Referenzdosimeter sowohl an den konventionellen als auch an den neuartigen Laser-Teilchenbeschleunigern erfolgreich eingesetzt werden. Zweitens bildete die durchgeführte Echtzeit- und Referenzdosimetrie laserbeschleunigter Elektronen die Grundlage für die weltweit ersten systematischen Zellbestrahlungsexperimente dieser Strahlenqualität. Dabei konnten trotz großer Pulsdosisschwankungen alle Anforderungen bezüglich Dosishomogenität, Strahlstabilität, präziser Deposition einer vorgegebenen Dosis und Unsicherheit der bestimmten applizierten Dosis, die für eine quantitative Auswertung der radiobiologischen Daten notwendig sind, erfüllt werden. Exemplarisch sei die bestimmte Gesamt-Dosisunsicherheit von unter 10% genannt. Drittens wurden auch laserbeschleunigte Protonen so präzise dosimetrisch monitoriert und charakterisiert, dass auch mit dieser Strahlenqualität quantitative strahlenbiologische Untersuchungen durchgeführt werden konnten. Herausgefordert durch die kurze Reichweite der Protonen im Submillimeterbereich und das breite Energiespektrum dieser Strahlenqualität, gelang dies neben der Charakterisierung und Kalibrierung der einzelnen Detektoren durch die Konzeption und Realisierung eines integrierten Dosimetrie- und Zellbestrahlungssystems (IDOCIS).Weltweit erstmalig wurde eine Echtzeit-Strahlmonitorierung während der Zellbestrahlungen mit laserbeschleunigten Protonen durchgeführt, die sowohl zur kontrollierten Applikation einer vorgegebenen Dosis und zur Strahlüberwachung als auch zusammen mit der durchgeführten Referenzdosimetrie zur hochpräzisen Bestimmung der absolut in den Zellen deponierten Dosis diente. Außerdem trug die parallele und redundante Verwendung zweier voneinander unabhängiger Referenzdosimetrie-Systeme erheblich zur Erreichung einer hohen Zuverlässigkeit und Sicherheit bei. Die Unsicherheit in der bestimmten deponierten Dosis betrug entsprechend für den Endpunkt der residualen DNS-Doppelstrangbrüche 24h nach Bestrahlung, für den eine vollständige Dosis-Effekt-Kurve ermittelt wurde, nur ca. 10%. Die Unsicherheit liegt damit schon fast in dem Bereich, der an klinisch angewandten Beschleunigern zulässig ist (3-5%). Dagegen konnte zu Beginn dieser Arbeit die Dosis laserbeschleunigter Protonen nur mit einer Ungenauigkeit von mehr als 50% abgeschätzt werden. Viertens wurden die zur Bestimmung der relativen biologischen Wirksamkeit notwendigen Vergleichsbestrahlungen mit konventionellen Elektronen- und Protonenstrahlenquellen und die zur Vergleichbarkeit der konventionellen und laserbeschleunigten Strahlenqualitäten erforderlichen Referenzbestrahlungen mit 200kVp Röntgenröhren im Rahmen dieser Arbeit ebenfalls dosimetrisch optimiert und genau charakterisiert. Die dosimetrischen Ergebnisse der vorliegenden Arbeit waren eine notwendige Voraussetzung für die im Rahmen anderer Arbeiten vollzogene strahlenbiologische Auswertung der durchgeführten Zellbestrahlungen. Dabei wurde insgesamt kein signifikanter Unterschied in der strahlenbiologischen Wirksamkeit zwischen laserbeschleunigten, ultrakurz gepulsten und konventionellen, kontinuierlichen Strahlenqualitäten weder für Elektronen noch für Protonen festgestellt. Durch die Konsistenz dieser Ergebnisse für beide Teilchenarten und unterschiedliche biologische Endpunkte ist damit die nächste Stufe auf dem translationalen Weg hin zur klinischen Anwendung laserbeschleunigter Teilchen begehbar: Die Durchführung von in vivo Untersuchungen. Dabei muss zwar von einer zweidimensionalen (Zell-Monolayer) auf eine dreidimensionale Zielvolumenbestrahlung (Tumor) übergegangen werden, wobei aber die im Rahmen der vorliegenden Arbeit entwickelten Dosimetrieverfahren und Detektoren auch bei den Tierbestrahlungen angewendet und eingesetzt werden können. / The application of high-intensity lasers for particle acceleration provides an alternative to conventional particle accelerators and also alternative beam qualities. Soon after the recent progress in the field of laser particle acceleration, its application in clinical ion therapy was proposed and discussed widely. Besides the improvement of the beam properties (increasing of beam energy and stability of particle acceleration process, e. g.) a capable physical and dosimetric characterization has to be developed before the technology can be applied in cancer therapy. The same is true for investigation of the biological effectiveness of this new, ultra-short pulsed beam quality with extremely high pulse dose rate. Hence, the whole translational chain, beginning from in vitro cell irradiation over in vivo studies to the point of preclinical investigations and first clinical trials, is necessary. For this reason, in a first step the joint research project onCOOPtics was founded and in vitro cell irradiation experiments were performed to study the biological effectiveness of laser accelerated particles. Therefore, dose-effect-curves for tumor and normal tissue cell lines were determined for different biological endpoints. Starting with extensive experiments with laser accelerated electrons at the JeTi laser system in Jena, the investigations were continued with dosimetric and radiobiological characterization of laser accelerated protons at the DRACO laser system in Dresden shortly after the DRACO laser started its operation. In this process, the development of a precise dosimetry for determination of the applied dose posed a great challenge due to the beam properties of laser accelerated particles. However, this is a crucial and compulsive requirement for both, the future clinical application and also for the realization of quantitative radiobiological experiments. Compiled in the onCOOPtics framework, this paper contributed to this task in multiple key aspects: Firstly, capable detectors for precise dosimetric characterization of laser accelerated electrons and protons were developed, optimized and characterized as well as precisely calibrated. Thus, comprehensive investigations were performed studying different properties of radiochromic films which are also applied in clinical dosimetry. In addition, these films were precisely calibrated for different beam qualities. Thereby, new findings of the energy dependence of radiochromic films were obtained which are of importance for numerous applications of these films. Moreover, different ionization chambers for real-time beam monitoring of laser accelerated electrons and protons were selected and characterized. Furthermore, the application of CR-39 solid state track detectors was established for spectroscopic investigations of laser accelerated protons by characterizing and optimizing the postirradiation processing and the readout of the detectors. Also a retrospective filter procedure of the detected tracks was developed and applied. Moreover, a Faraday Cup adjusted to the special properties of current laser accelerated proton beam qualities was developed, characterized and precisely calibrated by means of three independent calibration methods. Finally, the radiochromic films and the Faraday Cup could be used as reference dosimeters both for conventional accelerators and also for novel laser particle accelerators. Secondly, the performed real-time and reference dosimetry of laser accelerated electrons was the prerequisite of the first systematic cell irradiation experiments with this beam quality worldwide. Despite high pulse dose fluctuations, all requirements were satisfied concerning dose homogeneity, beam stability, precise deposition of a prescribed dose and uncertainty of the applied dose, that are all necessary for a quantitative evaluation of the radiobiological data. Exemplary, a total dose uncertainty below 10% was reached. Thirdly, laser accelerated protons were precisely monitored and characterized allowing quantitative, well-founded radiobiological investigations with this beam quality. This task was very much challenged by the short range of the protons in the sub-millimeter range and the broad energy spectrum of the beam quality. It was succeeded not only due to the comprehensive characterization and precise calibration of the different detectors but also due to the conception and realization of an integrated dosimetry and cell irradiation system (IDOCIS). For the first time, a real-time beam monitoring during cell irradiation with laser accelerated protons was performed. This real-time monitoring was not only used for controlled application of the prescribed dose and beam monitoring and also – together with the performed reference dosimetry – for precise determination of the deposited dose at cell location. In addition, high reliability and safety was considerably ensured by using two independent reference dosimetry systems in parallel. Hence, the determined uncertainty of the deposited dose was only about 10% for the biological endpoint of the residual DNA double strand breaks 24h after irradiation. For this endpoint a complete dose-effect-curve was obtained. Therefore, the achieved uncertainty is almost as small as necessary at clinically applied accelerators (3
416

The Acceleration of Charged Particles at a Spherical Shock Moving through an Irregular Magnetic Field

Giacalone, J. 23 October 2017 (has links)
We investigate the physics of charged-particle acceleration at spherical shocks moving into a uniform plasma containing a turbulent magnetic field with a uniform mean. This has applications to particle acceleration at astrophysical shocks, most notably, to supernovae blast waves. We numerically integrate the equations of motion of a large number of test protons moving under the influence of electric and magnetic fields determined from a kinematically defined plasma flow associated with a radially propagating blast wave. Distribution functions are determined from the positions and velocities of the protons. The unshocked plasma contains a magnetic field with a uniform mean and an irregular component having a Kolmogorov-like power spectrum. The field inside the blast wave is determined from Maxwell's equations. The angle between the average magnetic field and unit normal to the shock varies with position along its surface. It is quasi-perpendicular to the unit normal near the sphere's equator, and quasi-parallel to it near the poles. We find that the highest intensities of particles, accelerated by the shock, are at the poles of the blast wave. The particles "collect" at the poles as they approximately adhere to magnetic field lines that move poleward from their initial encounter with the shock at the equator, as the shock expands. The field lines at the poles have been connected to the shock the longest. We also find that the highest-energy protons are initially accelerated near the equator or near the quasi-perpendicular portion of the shock, where the acceleration is more rapid.
417

System-on-a-Chip (SoC) based Hardware Acceleration in Register Transfer Level (RTL) Design

Niu, Xinwei 08 November 2012 (has links)
Today, modern System-on-a-Chip (SoC) systems have grown rapidly due to the increased processing power, while maintaining the size of the hardware circuit. The number of transistors on a chip continues to increase, but current SoC designs may not be able to exploit the potential performance, especially with energy consumption and chip area becoming two major concerns. Traditional SoC designs usually separate software and hardware. Thus, the process of improving the system performance is a complicated task for both software and hardware designers. The aim of this research is to develop hardware acceleration workflow for software applications. Thus, system performance can be improved with constraints of energy consumption and on-chip resource costs. The characteristics of software applications can be identified by using profiling tools. Hardware acceleration can have significant performance improvement for highly mathematical calculations or repeated functions. The performance of SoC systems can then be improved, if the hardware acceleration method is used to accelerate the element that incurs performance overheads. The concepts mentioned in this study can be easily applied to a variety of sophisticated software applications. The contributions of SoC-based hardware acceleration in the hardware-software co-design platform include the following: (1) Software profiling methods are applied to H.264 Coder-Decoder (CODEC) core. The hotspot function of aimed application is identified by using critical attributes such as cycles per loop, loop rounds, etc. (2) Hardware acceleration method based on Field-Programmable Gate Array (FPGA) is used to resolve system bottlenecks and improve system performance. The identified hotspot function is then converted to a hardware accelerator and mapped onto the hardware platform. Two types of hardware acceleration methods – central bus design and co-processor design, are implemented for comparison in the proposed architecture. (3) System specifications, such as performance, energy consumption, and resource costs, are measured and analyzed. The trade-off of these three factors is compared and balanced. Different hardware accelerators are implemented and evaluated based on system requirements. 4) The system verification platform is designed based on Integrated Circuit (IC) workflow. Hardware optimization techniques are used for higher performance and less resource costs. Experimental results show that the proposed hardware acceleration workflow for software applications is an efficient technique. The system can reach 2.8X performance improvements and save 31.84% energy consumption by applying the Bus-IP design. The Co-processor design can have 7.9X performance and save 75.85% energy consumption.
418

Wide Area Application Services / Wide Area Application Services

Šlambor, Jan January 2008 (has links)
This thesis is trying to appraise benefits of implementation Cisco Wide Area Application Services (WAAS) in the organization. It's a relatively new technology, which seeks to answer the question, how to maintain control over the ever-increasing volume of traffic. This constant increase is mainly due to the use of new applications and business processes. WAAS should transparently improve throughput, speed and ease of use of all applications in the organization. The question is if this technology can reduce costs, improve productivity, simplify data protection, or what manner it is compatible with the corporate infrastructure. If is really consolidating and pooling application infrastructure for remote branch back into the data center best current solution, which facilitates access to remote users, in same way to which they are accustomed from the Local Area Network (LAN). The next one sections of this work will be summarized findings on the principle of Cisco WAAS. How the technology works. What is main optimizing method and how is currently use in the organization. It's weaknesses and strengths against the largest suppliers of similar WAN optimization solutions. The next one section will carry out an analysis, which showed us results to determine which applications are suitable for optimization technology and statements for the policy, which will be applied to the applications. This raises so many questions to be answered. The outcome of this work will be whether this technology is really what the organization needs, and whether this technology is applicable to all or only for certain types of applications or application protocols.
419

Kampen mellan defensiva och offensiva fotbollsspelare : En kvantitativ studie som undersöker samband mellan spänst och acceleration/snabbhet hos defensiva och offensiva fotbollsspelare.

Karlsson, Tobias, Gustafsson, Simon January 2017 (has links)
Bakgrund: Fotboll är väldens största sport med cirka 240 miljoner utövare i över 200 länder. För en fotbollsspelare är spänst ocksåav största vikt för att kunna hävda sig påplanen. Enligt tidigare studier finns det ett samband mellan att ha individerna med en god spänst även var snabba och hade en bra acceleration. Studier gjorda på elitspelare visar att försvarare och anfallare har bättre spänst än mittfältare. Denna studie har tidigare kartlagt syreupptagningsförmågan (Vo2 max) hos ett herrlag i division 5 lag och vill därför undersöka sambandet mellan spänst och acceleration/snabbhet hos samma studiepopulation. Det är av intresse att undersöka förhållandet mellan spänst och acceleration/snabbhet samt att undersöka skillnader mellan positioner på ett herrlag som spelar i division 5 i Sverige eftersom mycket av den tidigare forskningen visar resultat från professionella eller ungdomar. Syfte: Syftet med studien är att undersöka om det finns samband mellan spänst och snabbhet/acceleration samt om det skiljer sig mellan defensiva och offensiva positioner?Metod: Med hjälp av ett Counter Movement Jump (CMJ) test och 30 meter sprint test undersökte sambandet mellan spänst och acceleration/snabbhet på20 manliga fotbollsspelare i division 5.Resultat: Resultatet av studien visar på en signifikant korrelation mellan spänst och snabbhet, att offensiva besitter en bättre spänst/snabbhet.Diskussion: Resultaten är i linje med tidigare forskning som visar samband mellan spänst och acceleration/snabbhet. Dock visar resultatet från denna studie ingen signifikant skillnad mellan spänst och acceleration vilket kan bero på att studien använde sig av tidtagarur istället för fotoceller som är ett mer tillförlitligt instrument. Studien fann signifikanta skillnader i spänst och snabbhet mellan de defensiva och offensiva positionerna där de offensiva hade bäst resultat. För framtida forskning vore det intressant med en större kartläggning över alla divisioner för att kunna finna generaliserbara resultat och även göra tester på liknande idrotter.
420

Offloading Virtual Network Functions – Hierarchical Approach

Langlet, Jonatan January 2020 (has links)
Next generation mobile networks are designed to run in a virtualized environment, enabling rapid infrastructure deployment and high flexibility for coping with increasing traffic demands and new service requirements. Such network function virtualization imposes additional packet latencies and potential bottlenecks not present in legacy network equipment when run on dedicated hardware; such bottlenecks include PCIe transfer delays, virtualization overhead, and utilizing commodity server hardware which is not optimized for packet processing operations.Through recent developments in P4 programmable networking devices, it is possible to implement complex packet processing pipelines directly in the network data plane; allowing critical traffic flows to be offloaded and flexibly hardware accelerated on new programmable packet processing hardware, prior to entering the virtualized environment.In this thesis, we design and implement a novel hybrid NFV processing architecture which integrates programmable NICs and commodity server hardware, capable of offloading virtual network functions for specified traffic flows directly to the server network card; allowing these flows to completely bypass softwarization overhead, while less sensitive traffic process on the underlying host server.An evaluation in a testbed with customized traffic generators show that accelerated flows have significantly lower jitter and latency, compared with flows processed on commodity server hardware. Our evaluation gives important insights into the designs of such hardware accelerated virtual network deployments, showing that hybrid network architectures are a viable solution for enabling infrastructure scalability without sacrificing critical flow performance.

Page generated in 0.1555 seconds