• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 5
  • Tagged with
  • 22
  • 10
  • 8
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Enskilda avlopp i väntan på kommunal anslutning / On-site sewage systems while waiting for municipal wastewater

Håkansson, Anders January 2011 (has links)
Undermåliga enskilda avlopp i Östersjöns närområden bidrar till både övergödning ochförorening av havsvattnet. En av orsakerna är att sommarstugeområden i allt högre gradövergår till åretruntboende. Denna successiva förändring, skapar så kalladeomvandlingsområden, med i många fall otillräckliga avloppssystem. I takt med att flerväljer att bosätta sig permanent i dessa områden ökar belastningen på avloppen ochdärmed risken för läckage och föroreningar.Ett sätt att minska utsläppen är att bygga ut det kommunala avloppsledningsnätet tillomvandlingsområdena. Problemet är att det kan ta 5 – 10 år från planering avutbyggnad fram tills inkoppling av kommunalt avlopp kan ske på berörda fastigheter.Under den tiden behövs tillfälliga avloppssystem som kan användas somövergångslösningar, ersätta bristfälliga enskilda avlopp och förbättra miljön. Syftet medprojektet var att jämföra olika tänkbara tillfälliga avloppssystem med avseende påutsläpp, möjligt kretslopp, energianvändning, ekonomi och juridik. Målet var att hitta etteller flera alternativ som var lämpliga som tillfälliga avloppssystem.Metodiken som användes var en form av livscykelanalys (LCA), kostnadsanalys samtstudier av lagar och tidigare domar i liknande fall från miljööverdomstolen. VeVaverktygetanvändes för miljösystemanalysen och kostnadsanalysen. VeVa står för”Verktyg för hållbarhetsbedömning av VA-system i omvandlingsområden” och är ettExcelbaserat verktyg. Resultaten pekade på att urinsorterande torrtoalett med bad, diskoch tvättvatten (BDT-vatten) till kompaktfilter och minireningsverk för 25personekvivalenter (pe) blev de minst kostsamma systemen. Urinsorterande torrtoalettmed BDT till kompaktfilter visade sig kunna återföra både fosfor och kväve tillodlingsbar mark i hög grad och släppa ut minst fosfor och kväve av de analyseradesystemen. Slutsatsen var att urinsorterande torrtoalett med BDT till kompaktfilter varlämpligt som tillfälligt avloppssystem. Även minireningsverk för 25 pe visade siglämpligt ekonomiskt och energimässigt om ledningsdragningen kunde hållas kort ochsamma ledningar användas efter utbyggnad av kommunalt avlopp.
2

Vatten- och avloppssystem i klimatförändringarnas tidevarv : - en studie om VA-situationen i Karlstads kommun, dess sårbarheter och anpassningsförmåga

Persson, Erik January 2008 (has links)
<p>This report is about the impact climate change has on the water and sewage systems in general, and the situation in the municipality of Karlstad in particular. Which vulnerabilities are linked to water and sewage systems with regard to climate change and extreme weather situations, what are the possibilities to adapt the system to this and what significance does climate adaptation of the water and sewage systems have in relation to sustainable development?To answer these questions I have studied literature on the subject and interviewed several people who work with these types of questions. The answers I have received state that there are a multitude of vulnerabilities linked to the water- and sewage systems, but that there are also many strong interests which strive to take measures and adapt to a changed climate. I have also come to the conclusion that the starting points and views of the possibilities to act differs between the people that I have interviewed, but that theses problems are built into the concept of democracy.</p>
3

Tungmetaller i Bolidens spillvattenledningsnät - Identifiering av områden med höga metallhalter samt tänkbara källor.

Jansson, Jessica January 2015 (has links)
Åtminstone sedan början av 1980-talet har det varit känt att höga metallhalter förekommer i spillvattnet i gruvorten Boliden. Skellefteå kommun som ansvarar för driften av Bolidens avloppsreningsverk (ARV) vill försöka minska metallhalterna i vattnet eftersom slammet från reningsverket innehåller så höga tungmetallhalter att det måste tas om hand lokalt. Detta examensarbete syftar därför till att identifiera i vilka områden i spillvattennätet det förekommer höga metallhalter och vad orsaken till detta är. Resultaten från stickprover tagna i spillvattennätet visar att kadmium (Cd) och zink (Zn) förekommer i halter som är 14 gånger högre än kommunens tillåtna varningsvärden samt att koppar (Cu) förekommer i halter som är 5 gånger högre än det tillåtna varningsvärdet i den norra äldsta delen av Boliden. Gruvverksamheten som har ägt rum i området sedan 1920-talet identifieras som den största föroreningskällan. Sulfidhaltigt gruvavfall som lakar Cd, Cu och Zn har använts vid uppbyggnaden av de äldsta norra delarna av Boliden. På grund av att  pillvattenledningsnätet idag är gammalt och av dålig kvalitet förekommer därför ett stort inläckage av vatten med höga halter av dessa metaller i de norra delarna av samhället, vilket leder till att slammet från Bolidens ARV får ett högt innehåll av framförallt Cd och Zn.
4

Vatten- och avloppssystem i klimatförändringarnas tidevarv : - en studie om VA-situationen i Karlstads kommun, dess sårbarheter och anpassningsförmåga

Persson, Erik January 2008 (has links)
This report is about the impact climate change has on the water and sewage systems in general, and the situation in the municipality of Karlstad in particular. Which vulnerabilities are linked to water and sewage systems with regard to climate change and extreme weather situations, what are the possibilities to adapt the system to this and what significance does climate adaptation of the water and sewage systems have in relation to sustainable development?To answer these questions I have studied literature on the subject and interviewed several people who work with these types of questions. The answers I have received state that there are a multitude of vulnerabilities linked to the water- and sewage systems, but that there are also many strong interests which strive to take measures and adapt to a changed climate. I have also come to the conclusion that the starting points and views of the possibilities to act differs between the people that I have interviewed, but that theses problems are built into the concept of democracy.
5

Källsorterande avloppssystem : ett rimligt alternativ till konventionella reningsverk? Exemplet Ekoporten / Source separating systems : an alternative to conventional wastewater solutions? The example Ekoporten

Norberg, Karin January 2002 (has links)
<p>Ekonomi, miljö och socio-kulturella aspekter har analyserats för ett källsorterande avloppssystem och ett konventionellt reningsverk genom en fallstudie. Hyreshuset Ekoportens källsorterande avloppssystem, med urinsortering, har jämförts med reningsverket Slottshagen i Norrköping. Kostnader har analyserats genom kostnadseffektivitetsanalys och miljöaspekter har jämförts genom analys av resurshushållning av näringsämnen och areal. För analys av socio-kulturella aspekter har intervjuer gjorts med Ekoportens boende samt genom studier av erfarenheter från andra undersökningar. </p><p>Analysen visar att Ekoportens avloppssystem är fem gånger dyrare per personekvivalent och år än Slottshagens reningsverk. Återförsel av kväve och fosfor till odlingsmark från Ekoporten är åttio respektive tio gånger högre än från Slottshagen. Ekoporten har 20% mindre utsläpp av kväve medan Slottshagen har 28% bättre fosforrening och tio gånger bättre resurshushållning av areal. Socio-kulturell analys visar att kravet att sitta ned för att urinsortera är den stora skillnaden mot konventionellt reningsverk. </p><p>Slutsatsen är att urinsorterande avloppssystem är ett rimligt komplement till konventionella reningsverk. Urinsortering kan minska avloppsvattnets kväveinnehåll med 40-80%. Avloppssystem likt Ekoportens behöver dock bli mer ekonomiskt fördelaktiga och måste skyddas mot olämplig användning för att minska dess negativa miljöaspekter.</p>
6

Källsorterande avloppssystem : ett rimligt alternativ till konventionella reningsverk? Exemplet Ekoporten / Source separating systems : an alternative to conventional wastewater solutions? The example Ekoporten

Norberg, Karin January 2002 (has links)
Ekonomi, miljö och socio-kulturella aspekter har analyserats för ett källsorterande avloppssystem och ett konventionellt reningsverk genom en fallstudie. Hyreshuset Ekoportens källsorterande avloppssystem, med urinsortering, har jämförts med reningsverket Slottshagen i Norrköping. Kostnader har analyserats genom kostnadseffektivitetsanalys och miljöaspekter har jämförts genom analys av resurshushållning av näringsämnen och areal. För analys av socio-kulturella aspekter har intervjuer gjorts med Ekoportens boende samt genom studier av erfarenheter från andra undersökningar. Analysen visar att Ekoportens avloppssystem är fem gånger dyrare per personekvivalent och år än Slottshagens reningsverk. Återförsel av kväve och fosfor till odlingsmark från Ekoporten är åttio respektive tio gånger högre än från Slottshagen. Ekoporten har 20% mindre utsläpp av kväve medan Slottshagen har 28% bättre fosforrening och tio gånger bättre resurshushållning av areal. Socio-kulturell analys visar att kravet att sitta ned för att urinsortera är den stora skillnaden mot konventionellt reningsverk. Slutsatsen är att urinsorterande avloppssystem är ett rimligt komplement till konventionella reningsverk. Urinsortering kan minska avloppsvattnets kväveinnehåll med 40-80%. Avloppssystem likt Ekoportens behöver dock bli mer ekonomiskt fördelaktiga och måste skyddas mot olämplig användning för att minska dess negativa miljöaspekter.
7

Svavelväteproblematiken i svenska spillvattensystem : En studie i hur olika åtgärder har fungerat

Spengler, Clara January 2020 (has links)
Svavelväte, H2S, är en giftig och illaluktande gas. Den karakteristika ''ruttet ägg''-lukten kan kännas redan 0.02ppm och det hygieniska gränsvärdet för exponering under en arbetsdag ligger på 5ppm, enligt arbetsmiljöverkets restriktioner. Dessutom är gasen korrosiv på betong och övrig utrustning och minskar därmed livslängden på ledningssystem. Svavelväte bildas i avloppsvatten under anaeroba förhållanden vilka typiskt uppstår i spillvattenledningar med långa uppehållstider. Syftet med detta arbetet var att kartlägga vilka åtgärder för att minska bildningen av svavelväte som användes, hur dessa har fungerat i praktiken samt försöka hitta ett samband mellan vilka åtgärder som passar i vilket typ av system. Detta gjordes med en grundläggande litteraturstudie samt datainsamling via telefon, e-mail och intervjuer. Studien visar att dosering med kemikalier var den vanligaste åtgärden följt av någon typ av luftningsanordning. Mätningar på hur svavelvätehalter påverkas i samband med dessa åtgärder var dock svåra att hitta.  Arbetet visade på en komplexitet i bildandet av svavelväte. De fysiska förutsättningarna i ledningarna såsom dimensioner, flödeshastighet, temperatur etc. påverkar också svavelvätebildingen. Förutsättningarna i ledningarna beror av många faktorer vilka ständigt varierar. Samtliga beskrivna åtgärder har enligt de kommuner där de införts och testats haft önskad effekt utifrån en subjektiv bedömning. Studien visar att grundläggande mätningar är nödvändiga för att klargöra vilka åtgärder som är mest effektiva vid givna förutsättningar. För att i framtiden kunna tackla detta antagligen växande problem i svenska ledningsnät bör alltså fler och noggrannare mätningar göras. Mätningarna bör göras både innan och efter en åtgärd sats in samt uppföljande mätning för att se om åtgärden bibehåller önskad effekt. En databas med denna typ av mätningar skulle dels gynna framtida forskning, dels hjälpa kommuner att välja rätt metod för att lösa svavelvätereleaterade problem. / Hydrogen sulphide is a toxic gas with a malodorous smell. Even in very low amounts, 0.02ppm, the rotten egg odor is noticable. The limit exposure per day is 5ppm according to The Swedish Work Environment Authority's restrictions. In addition, the gas is very corrosive to concrete and equipment, thus reducing the lifetime of wastewater collection systems. Hydrogen sulphide is formed in wastewater under anaerobic conditions, which typically occur in wastewater systems with long residence times. The aim of this study was to find which methods are used to reduce the formation of hydrogen sulphide. How these have preformed in practice and try to find a connection between which methods are suitable in which type of system. This was done with a literature study as well as data collection via telephone, e-mail and interviews.  Dosing with chemicals proved to be the most common method to reduce hydrogen sulphide, followed by some kind of ventilation devices. Measurements of hydrogen sulphide content in connection with these methods was, however, difficult to find among the contacted users.  This study showed a complexity in the formation of hydrogen sulphide since the conditions in wastewater collection systems depend on many factors which constantly varies. According to the municipalities where methods were introduced and tested, the desired effect based on a subjective assessment was reached. The study shows that measurements are necessary to clarify which methods are most effective under given conditions.  In order to deal with this possibly growing problem in Swedish waste water collection systems, more accurate data collection should be done. Both before, after and follow up data, regarding the intervention should be collected when studying this issue. Doing so would greatly benefit future research and help municipalities in solving this problem.
8

TEKNIK ÄR LIVET : En studie om elevers kunskaper om tekniska system och vatten och avloppssystemet / Technology is part of life : A study of students' knowledge of technical systems and the water and sewage system

Vesterlund, Angelica January 2023 (has links)
Syftet med denna studie var att få reda på om designprocessen ökar elevernas kunskaper om det tekniska systemet vatten- och avloppssystemet. Frågeställningarna som studien har som syfte att besvara är: Vilken kunskap har eleverna i årskurs 5 om tekniska system innan genomförd undervisning? Hur kan en designaktivitet bidra till att eleverna utvecklar kunskaper om vatten- och avloppssystem? samt Vilka kvalitativa skilda kunskaper utvecklades under designaktiviteten? En undervisningssekvens på fyra lektioner har genomförts i en femteklass. Till största delen bestod lektionerna av samtal och skapande aktiviteter som observerades och dokumenterades genom loggboksanteckningar. Deltagarna genomförde ett förkunskapstest som hade syftet att samla in datamaterial för att besvara den första frågeställningen. Observationer och intervju utfördes för att besvara den andra och tredje frågeställningen. Resultatet visade att eleverna hade för­kun­skaper om tekniska system kopplade till föremål. Vidare visade resultatet att det fanns faktorer som påverkade elevernas inhämtande av kunskap såsom samarbete, dialog och lärarens handledning. Dessa faktorer påverkade hur elevernas kunskaper ökade under designaktiviteten och visade på kvalitativa skillnader i elevernas kunskaper om vatten- och avloppssystemet.
9

Metodik för beräkning av anslutna hårdgjorda ytor till spillvattennätet / Techniques for calculation of impervious surfaces connected to the sewer system

Larsson, Johan January 2010 (has links)
<p>Sveriges avloppsledningsnät förnyas och utvidgas kontinuerligt. Idag finns ett flertal datorprogram för hydraulisk modellering av flöden och uppdämningsnivåer i spill- och dagvattennät. Modellerna kan även användas som planeringsverktyg för att bedöma effekter av planerade åtgärder samt för uppföljning av utförda åtgärder. Vid uppbyggnaden av en modell krävs beräkningsresultat från en hydrologisk avrinningsmodell som indata. Det största arbetet vid modelluppbyggandet ligger just i beskrivningen av hydrologin. För att kunna simulera avrinningsförlopp i samband med nederbörd på ett verklighetsliknande sätt är kännedom om storleken på och fördelningen av anslutna hårdgjorda ytor till ledningsnätet med snabb nederbördsavrinning väsentligt. </p><p> </p><p>Till kalibreringen och valideringen av avloppsmodellen krävs mätdata. Flödesmätningar är dyra att genomföra vilket har skapat ett intresse att hitta metoder som säkert beräknar de anslutna hårdgjorda ytorna redan från de uppgifter som finns på kartor och i databaser. Svenska riktlinjer för beräkning av hårdgjorda ytor tillhandahålls av branschorganisationen Svenskt Vatten som företräder VA-verken och VA-bolagen i Sverige. Beräkningar med dessa riktlinjer ger dock inte alltid den korrekta storleken på de hårdgjorda ytorna. Syftet med examensarbetet har varit att undersöka olika metoder att beräkna anslutna hårdgjorda ytor till spillvattennätet samt att undersöka huruvida det finns ett samband mellan de avrinningsområden där beräkningarna av de hårdgjorda ytorna inte stämmer. Nio befintliga modeller framtagna i modelleringsverktyget MIKE URBAN användes vid undersökningen. Sex av dessa modeller användes till kalibrering och tre modeller användes till validering.</p><p> </p><p>Undersökningen visade inget samband mellan ytavrinning (reduktionsfaktor) och lutning. Fördelningen av mätpunkter mellan olika jordartskategorier var väldigt ojämn vilket gjorde det svårt att studera huruvida det finns ett samband mellan avrinning och jordart. Resultatet från undersökningen visar att avrinningskoefficienter bör delas upp efter typ av ledningsnät i avrinningsområdet. Metoden med olika avrinningskoefficienter för olika typer av ytor visar på bra resultat för tätbebyggda områden. Metoden med sammanvägda avrinningskoefficienter för olika bebyggelsetyper visar relativt bra resultat med tanke på att det är en överslagsberäkningsmetod.</p><p> </p><p>För tätbebyggda områden bedöms metoden med avrinningskoefficienter för olika typer av ytor fungera bra. Vid mindre tätbebyggda områden ökar osäkerheten. Metoden med sammanvägda avrinningskoefficienter för olika bebyggelsetyper bedöms fungera väl för överslagsberäkningar då den är mindre tidskrävande än den andra metoden. Ingen av de undersökta metoderna bedöms kunna ersätta flödesmätningar. </p> / <p>Sweden’s sewage systems are continuously being maintained and expanded. Several computer programs are today available for hydraulic modeling in sewage and storm water systems. The models can also be used as a planning tool to evaluate effects of planned interventions and to follow up performed interventions. Input data from a runoff model is required at the model build-up. Most of the work in model build-up lies at the description of the hydrology. In order to simulate runoff processes in connection with precipitation, understanding of the size and distribution of impervious surfaces with fast response runoff are essential.</p><p> </p><p>Measurements are required for the calibration and validity check of the model. Unfortunately, flow measurements are expensive to perform. This has created an interest to find methods that safely calculate the connected impervious surfaces already from the information that can be found in maps and in databases. The Swedish guidelines for calculation of impervious surfaces are provided by the Swedish Water and Wastewater Association. Calculations with these guidelines do not always give the true size of the impervious surfaces. The aim of this master thesis was to examine various methods to calculate impervious surfaces connected to the sewage system and whether there is a correlation between drainage areas where the calculations do not agree. Nine existing models developed in the computer program MIKE URBAN were used in this study. Six of these models were used in the calibration and three models were used in the validity check of the methods.</p><p> </p><p>The study did not show any correlation between runoff (reduction factor) and slope. The distribution of datum points between different soil types varied so much that it made it difficult to study whether there was correlation between runoff and soil type. The result from the study showed that the runoff coefficients should be divided after type of sewage system in the drainage area. The method with runoff coefficients for different types of surfaces showed fairly good results for highly urbanized areas. The method with weighted runoff coefficients for different types of habitations showed relatively good results considering that it is a method for rough calculations.</p><p> </p><p>The method with runoff coefficients for different types of surfaces is considered well-functioning for highly urbanized areas. In less urbanized areas, this method showed shorter results. The method with weighted runoff coefficients for different types of habitations is considered well for rough calculations when it is less time consuming than the other method. None of the examined methods are considered able to replace flow measurements.</p>
10

Metodik för beräkning av anslutna hårdgjorda ytor till spillvattennätet / Techniques for calculation of impervious surfaces connected to the sewer system

Larsson, Johan January 2010 (has links)
Sveriges avloppsledningsnät förnyas och utvidgas kontinuerligt. Idag finns ett flertal datorprogram för hydraulisk modellering av flöden och uppdämningsnivåer i spill- och dagvattennät. Modellerna kan även användas som planeringsverktyg för att bedöma effekter av planerade åtgärder samt för uppföljning av utförda åtgärder. Vid uppbyggnaden av en modell krävs beräkningsresultat från en hydrologisk avrinningsmodell som indata. Det största arbetet vid modelluppbyggandet ligger just i beskrivningen av hydrologin. För att kunna simulera avrinningsförlopp i samband med nederbörd på ett verklighetsliknande sätt är kännedom om storleken på och fördelningen av anslutna hårdgjorda ytor till ledningsnätet med snabb nederbördsavrinning väsentligt.    Till kalibreringen och valideringen av avloppsmodellen krävs mätdata. Flödesmätningar är dyra att genomföra vilket har skapat ett intresse att hitta metoder som säkert beräknar de anslutna hårdgjorda ytorna redan från de uppgifter som finns på kartor och i databaser. Svenska riktlinjer för beräkning av hårdgjorda ytor tillhandahålls av branschorganisationen Svenskt Vatten som företräder VA-verken och VA-bolagen i Sverige. Beräkningar med dessa riktlinjer ger dock inte alltid den korrekta storleken på de hårdgjorda ytorna. Syftet med examensarbetet har varit att undersöka olika metoder att beräkna anslutna hårdgjorda ytor till spillvattennätet samt att undersöka huruvida det finns ett samband mellan de avrinningsområden där beräkningarna av de hårdgjorda ytorna inte stämmer. Nio befintliga modeller framtagna i modelleringsverktyget MIKE URBAN användes vid undersökningen. Sex av dessa modeller användes till kalibrering och tre modeller användes till validering.   Undersökningen visade inget samband mellan ytavrinning (reduktionsfaktor) och lutning. Fördelningen av mätpunkter mellan olika jordartskategorier var väldigt ojämn vilket gjorde det svårt att studera huruvida det finns ett samband mellan avrinning och jordart. Resultatet från undersökningen visar att avrinningskoefficienter bör delas upp efter typ av ledningsnät i avrinningsområdet. Metoden med olika avrinningskoefficienter för olika typer av ytor visar på bra resultat för tätbebyggda områden. Metoden med sammanvägda avrinningskoefficienter för olika bebyggelsetyper visar relativt bra resultat med tanke på att det är en överslagsberäkningsmetod.   För tätbebyggda områden bedöms metoden med avrinningskoefficienter för olika typer av ytor fungera bra. Vid mindre tätbebyggda områden ökar osäkerheten. Metoden med sammanvägda avrinningskoefficienter för olika bebyggelsetyper bedöms fungera väl för överslagsberäkningar då den är mindre tidskrävande än den andra metoden. Ingen av de undersökta metoderna bedöms kunna ersätta flödesmätningar. / Sweden’s sewage systems are continuously being maintained and expanded. Several computer programs are today available for hydraulic modeling in sewage and storm water systems. The models can also be used as a planning tool to evaluate effects of planned interventions and to follow up performed interventions. Input data from a runoff model is required at the model build-up. Most of the work in model build-up lies at the description of the hydrology. In order to simulate runoff processes in connection with precipitation, understanding of the size and distribution of impervious surfaces with fast response runoff are essential.   Measurements are required for the calibration and validity check of the model. Unfortunately, flow measurements are expensive to perform. This has created an interest to find methods that safely calculate the connected impervious surfaces already from the information that can be found in maps and in databases. The Swedish guidelines for calculation of impervious surfaces are provided by the Swedish Water and Wastewater Association. Calculations with these guidelines do not always give the true size of the impervious surfaces. The aim of this master thesis was to examine various methods to calculate impervious surfaces connected to the sewage system and whether there is a correlation between drainage areas where the calculations do not agree. Nine existing models developed in the computer program MIKE URBAN were used in this study. Six of these models were used in the calibration and three models were used in the validity check of the methods.   The study did not show any correlation between runoff (reduction factor) and slope. The distribution of datum points between different soil types varied so much that it made it difficult to study whether there was correlation between runoff and soil type. The result from the study showed that the runoff coefficients should be divided after type of sewage system in the drainage area. The method with runoff coefficients for different types of surfaces showed fairly good results for highly urbanized areas. The method with weighted runoff coefficients for different types of habitations showed relatively good results considering that it is a method for rough calculations.   The method with runoff coefficients for different types of surfaces is considered well-functioning for highly urbanized areas. In less urbanized areas, this method showed shorter results. The method with weighted runoff coefficients for different types of habitations is considered well for rough calculations when it is less time consuming than the other method. None of the examined methods are considered able to replace flow measurements.

Page generated in 0.0659 seconds