• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 131
  • 63
  • 10
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 240
  • 125
  • 72
  • 67
  • 57
  • 55
  • 53
  • 39
  • 38
  • 38
  • 38
  • 37
  • 23
  • 20
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Incidência e fatores de risco de remoção por suspeita de infecção de corrente sanguínea associada ao cateter central de inserção periférica em uma coorte de neonatos / Incidence and risk factors of removal due to suspected catheter-associated bloodstream infection of Peripherally Inserted Central Catheter in a cohort of neonates.

Magalhães, Talita Elci de Castro 26 July 2013 (has links)
Introdução: o cateter central de inserção periférica (CCIP) tornou-se amplamente utilizado nas unidades de terapia intensiva neonatal (UTIN) na última década em razão da facilidade de sua instalação, permitindo a infusão de soluções endovenosas vesicantes, irritantes, hiperosmolares e de longa duração em veias centrais. Uma das complicações mais temidas relacionadas ao uso do CCIP é infecção de corrente sanguínea associada ao cateter cujo diagnóstico se confirma somente após a sua remoção, com o resultado de cultura da ponta do dispositivo e o resultado de hemocultura periférica do neonato. Objetivo: determinar a incidência de remoção por suspeita de infecção de corrente sanguínea relacionada ao CCIP e identificar os seus fatores de risco. Metodologia: coorte prospectiva composta por neonatos com CCIP internados em uma Unidade de Terapia Intensiva Neonatal de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 30 de agosto de 2012. As variáveis de exposição analisadas foram às relacionadas às características demográficas e clinicas dos neonatos, procedimentos relacionados à inserção do cateter, tipo de terapia intravenosa infundida pelo CCIP e o tempo de permanência do cateter. O desfecho analisado foi o motivo de remoção do cateter - eletivo ou por suspeita de infecção. Os dados obtidos de registros de prontuário foram armazenados em planilha Microsoft Excel 2010® e analisados com o software Stata 11,1. Foram determinadas medidas de tendência central e dispersão para as variáveis contínuas e frequências absolutas e relativas para as variáveis nominais. A existência de associação entre as variáveis de exposição e desfecho foi determinada pelo teste Qui-quadrado (teste 2), exato de Fisher e t Student. As variáveis com valor p < 0,05 foram incluídas na análise multivariada com regressão de Poisson. O nível de significância estatística adotado foi p < 0,05 com intervalo de confiança de 95%. O projeto de pesquisa foi aprovado pelo Comitê de Ética e Pesquisa da instituição campo do estudo. Resultados: A coorte inicial foi composta por 551 neonatos com CCIP e atenderam os critérios de elegibilidade, 401. A incidência de remoção por suspeita de infecção associada ao cateter foi 13,7%. A média de permanência de cateteres removidos por suspeita de infecção foi de 16,4 dias e dos removidos eletivamente, 11,7 dias, valor p=0,0001. Os fatores de risco para remoção por suspeita de infecção foram os diagnósticos de distúrbio hidroeletrolítico, RR 3.04. IC95%[1,727-5,054], valor p = 0,000 e apnéia, RR 2,38, IC95% [1,105-4,564], valor p = 0,016. As variáveis, média da idade gestacional corrigida superior a 32 semanas, RR 0,893, IC95% [0,832-0,956], valor p = 0,002 e o uso de cateter monolúmen de silicone, RR 0,278, IC95% [0,128-0,536], valor p = 0,000 se configuraram como fatores de proteção para remoção por suspeita de infecção associada ao CCIP. Dos 72 cateteres removidos por suspeita de infecção, 3 (4,2%)apresentaram confirmação de infecção do cateter. Conclusão: Os resultados sugerem que os diagnósticos identificados como fatores de risco devem ser incluídos no protocolo assistencial como fatores preditores de remoção por suspeita de infecção. Estes recém-nascidos necessitam ser especialmente monitorados em busca de sinais de infecção. Além disso, a escolha do tipo de dispositivo CCIP deve ser objeto de mais investigações, bem como os critérios de decisão para remoção do CCIP, por suspeita de infecção, tendo em vista a reduzida frequência de confirmação de infecção entre os cateteres removidos por suspeita. / Introduction: The peripherally inserted central catheter (PICC line) has become widely used in the neonatal intensive care units (NICU) in the last decades due to its ease installation and to allow infusion of vesicant, irritant and hiperosmolar solutions by long period in central veins. One of the most feared complications related to the use of PICC lines is the catheter associated bloodstream infection, which is confirmed after its removal with the result of catheter\'s tip culture and the results of neonate peripheral blood culture. Objective: to determine the incidence of removal due to PICC-line associated bloodstream infection and identify its risk factors. Methods: a prospective cohort of neonates with PICC line hospitalized in a NICU of a private hospital of the city of São Paulo. Data were collected from August 31st, 2010 to August 30th, 2012. The independent variables analyzed were related to demographic and clinical characteristics of newborns, procedures related to insertion of catheter, type of intravenous therapy infused and the catheter dwell time. The outcome variable analyzed was the reason for catheter removal elective or due to PICC-line suspected bloodstream infection. Data were obtained from the medical charts and stored in Microsoft Excel 2010 ® spreadsheet. Statistics analysis was conducted in the software Stata 11.1®. The continuous variables were showed by central and dispersion tendency measures and for qualitative variables, the data were showed by absolute and relative frequencies. The association between independent and outcome variables was determined by chi-square test (2), Fisher exact and t Student. Variables with p <0.05 were included in Poisson multivariate regression model. The level of statistical significance adopted was p<0.05 with a confidence interval of 95%. The research project was approved by the Ethics and Research Committee of the hospital where the study was carried out. Results: the initial cohort was composed of 551 neonates with PICC-line and 401 met the eligibility criteria. The incidence of suspected catheter associated bloodstream infection removal was 13.7%. The mean dwell time of PICC removed due suspicious of infection was 16,4 days and due to elective removal was 11,7 days, p value=0,0001. The risk factors for catheter-associated bloodstream infection identified were the diagnosis of hydroelectrolytic disorder, RR 3.04, CI95% [1.727 - 5.054], p value= 0.000 and diagnose of apnea, RR 2.38, CI95% [1.105 - 4.564], p value=0.016. The variables identified as protective factors for removal due suspected infection were: corrected gestational age of more than 32 weeks, RR 0.893, CI95% [0.832 - 0.956], p value=0.002 and single-lumen silicone catheter, RR 0.278, CI95% [0.128 - 0.536], p value= 0.000. From 72 catheters removed due to PICC-line suspicious of bloodstream infection, the infection was confirmed only to 3 (4.2%)of them. Conclusion: The results suggested that the diagnosis identified as risk factors should be included in the protocol of PICC lines management as predictors for removal due to suspected of infection. These neonates need to be carefully monitored for signs of infection. Moreover, choosing the most appropriate type of PICC should be further investigated, as well as the criteria to support the decision of removing the catheter considering the low number of confirmed catheter-associated infection.
122

Adesividade e irritação cutânea do filme transparente gel de clorexidina em pacientes submetidos ao transplante de células tronco hematopoiéticas / Adhesiveness and skin rash related to the transparent film dressing with chlorhexidine gel applied to patients submitted to hematopoietic stem cell transplantation

Santos, Bruna Nogueira dos 21 September 2015 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) trata-se da substituição das Células-Tronco Hematopoéticas (CTH) doentes de um indivíduo por CTH normais com o objetivo de normalizar a hematopoese do receptor. O cateter venoso central (CVC) tornou-se indispensável para viabilizar tal terapêutica pela segurança na infusão das CTH e dos quimioterápicos. Para o TCTH são utilizados cateteres do tipo Hickman ou duplo lúmen, ambos de longa permanência. O curativo adesivo utilizado no sítio de inserção do cateter é essencial para a fixação do cateter, proteção contra agentes externos e prevenção de infecção. Há forte evidência clínica no uso do filme transparente gel de clorexidina (CHX) como uma alternativa no controle de infecções relacionadas ao cateter. A adesividade deste curativo confere-lhe uma possível permanência de até sete dias aderido à pele, o que evita repetidas aplicações e remoções do curativo, diminui a frequência na manipulação do cateter, a ocorrência de infecção e irritação cutânea local. Observa-se que a adesividade do curativo nem sempre permite a permanência por sete dias, sendo necessárias trocas não planejadas, podendo causar lesões à integridade cutânea. Neste estudo, objetivou-se avaliar a adesividade e a irritação cutânea do filme transparente gel de CHX aplicado no sítio de inserção do CVC por meio de um estudo transversal, prospectivo, realizado em um hospital público de ensino, no período de novembro de 2013 a junho de 2014, com crianças e adultos de ambos os sexos com doenças autoimunes ou onco-hematológicas submetidos ao TCTH. A amostra desta pesquisa foi constituída por 25 pacientes. Onze (44%) apresentaram irritação cutânea caracterizada por perda de pele de extensão <=0,5cm, perda de pele de extensão > 0,5cm, placa eritematosa e vesículas. Destes, seis tiveram necessidade de suspensão do uso do curativo. A pele fragilizada devido ao uso de agentes quimioterápicos pode aderir fortemente ao curativo adesivo, sendo desprendida com o mesmo quando este é removido. A perda da integridade cutânea com remoção da camada protetora da pele facilita a entrada de microrganismos aumentando a susceptibilidade a infecções em pacientes imunossuprimidos. Em 55,6% das avaliações foi observado desprendimento do curativo e a região da fenda foi onde mais ocorreu desprendimento (43,4%). Esta é uma região da margem do curativo, assim denominada por possuir uma abertura no adesivo onde são posicionadas as vias do cateter. Infere-se que devido à mobilidade do paciente e manuseio das vias do cateter, com o passar dos dias, essa região da borda do curativo apresenta maior desprendimento. Em 8,4% das observações havia bolha de ar no gel de clorexidina envolvendo o sítio de inserção do cateter. A bolha de ar no gel de clorexidina significa que este não está em contato com a pele do paciente o que é preocupante quando envolve o sítio de inserção do cateter, pois a CHX não está exercendo sua função antisséptica neste local, onde há possibilidade de migração extra- lúmen de microrganismos à corrente sanguínea / Hematopoietic stem cell transplantation (HSCT) involves the replacement of sick hematopoietic stem cells (HSC) from an individual with normal HSC, with the aim to restore the recipient\'s hematopoiesis. Central venous catheters (CVC) have become indispensable to make this therapy feasible due to the safety of infusion of the HSC and the chemotherapeutic agents. In HSCT, long-term Hickman or long-term double lumen catheters are used. The adhesive dressing used in the site of insertion of the catheter is essential for the catheter fixation, protection against external agents and prevention of infection. There is strong clinical evidence on the use of transparent film dressing with chlorhexidine gel (CHX) as an alternative in the control of catheter-related infections. The adhesiveness of this dressing allows it to be used up to seven days once it adheres to the skin, which avoids repeated dressing applications and removals, and reduces the frequency of catheter handling, the occurrence of infection, and local skin rash. However, as observed, the dressing adhesiveness does not always allow it to be used for seven days, and unplanned replacements may be needed, which can cause lesions to the skin integrity. The objective of this study was to evaluate the adhesiveness and skin rash related to the transparent film dressing with CHX gel applied at the site of insertion of the CVC by means of a cross-sectional, prospective study developed at a public teaching hospital, between November 2013 and June 2014, with children and adults of both genders with autoimmune or onco-hematological diseases who were submitted to HSCT. The sample comprised 25 patients. Eleven (44%) presented skin rash characterized by skin loss to an extension of <=0.5 cm, skin loss to an extension of > 0.5 cm, erythematous plaque and vesicles. Of these, six had to interrupt the use of the dressing. Frail skin due to the use of chemotherapeutic agents can adhere strongly to the adhesive dressing, coming off with the dressing at its removal. The loss of skin integrity with the removal of the skin\'s protective layer facilitates the entrance of microorganisms, increasing susceptibility to infections in immunosuppressed patients. In 55.6% of the evaluations, there was dressing detachment, and it was greater in the opening region (43.4%), which is a region in the dressing border with a break in the adhesive where the catheter is placed. Given the mobility of the patient and the handling of the catheter, over the days, this region of the dressing border presents greater detachment. In 8.4% of the observations there were air bubbles in the chlorhexidine gel involving the site of insertion of the catheter. Air bubbles in the chlorhexidine gel means that it is not in contact with the patient\'s skin, which is a cause of concern when the site of insertion of a catheter is involved, since CHX is not exerting its antiseptic function in this location, which can lead to extra-lumen migration of microorganisms to the bloodstream
123

Tipo de cateter central de inserção periférica e o motivo de sua remoção em uma coorte de neonatos / Type of peripherally inserted central catheter device and the reason for its removal in a cohort of neonates

Paiva, Eny Dórea 30 July 2012 (has links)
Introdução: Dispositivos de acesso venoso central tornaram-se vitais para a recuperação e sobrevivência dos neonatos e lactentes internados em Unidade de Terapia Intensiva Neonatal (UTIN). O cateter central de inserção periférica (CCIP) tem sido amplamente utilizado para atender às demandas terapêuticas dos neonatos e lactentes criticamente doentes e inovações nos dispositivos têm sido introduzidos e confeccionados com materiais biocompatíveis, como o silicone e o poliuretano, com único ou duplo lúmen. Objetivo: analisar a relação entre os tipos de cateteres centrais de inserção periférica (monolúmen de silicone e duplolúmen de poliuretano) instalados em neonatos e lactentes com os motivos de remoção do dispositivo. Método: coorte prospectiva, composta por neonatos e lactentes submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo, no período de 1 de julho de 2010 a 30 de junho de 2011. Os neonatos e lactentes foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 219/2010). Resultados: foram analisados dados referentes a 270 CCIPs, 189 (70%) cateteres de monolúmen e 81 (30%) de duplolúmen. Os dois grupos de cateteres apresentaram características demográficas, clínicas, terapêuticas e relacionadas ao procedimento de inserção do cateter homogêneas, exceto para as variáveis: diagnóstico prévio de septicemia (p=0,0210) e ocorrência de dificuldade de progressão do cateter na instalação do mesmo (p=0,0296). Contudo, o valor de p para o teste de homogeneidade para razão de chances do diagnóstico prévio de septicemia e da dificuldade de progressão do cateter, não demonstrou diferença estatística, p=0,955 e p=0,400, respectivamente. A taxa de densidade de incidência (TI) de remoção não eletiva para o cateter monolúmen de silicone foi 34,8 em 1.000 cateteres-dia e a do cateter duplolúmen de poliuretano foi 32,8 em 1.000 cateteres-dia. Houve diferença estatística significante, p=0,0005, na média do tempo de permanência entre os dois tipos de cateteres, maior para o dispositivo de duplolúmen de poliuretano, 14 dias em relação ao dispositivo de monolúmen de silicone, 10 dias. Entretanto, não é possível afirmar que a taxa de densidade de incidência entre os cateteres se diferem entre si ao se estimar a curva de sobrevida pelo método Kaplan Meier dos cateteres com remoção não eletiva. As curvas de sobrevivência de ambos os cateteres se sobrepõem, entretanto o valor do logrank (0,45) indica que não há diferença estatística entre a incidência de remoção não eletiva entre os cateteres. Dessa forma, a hipótese conceitual defendida no presente estudo não pode ser confirmada. Conclusão: os resultados do estudo apontaram que não há diferença estatística significante nas taxas de incidência de remoção não eletiva entre os dois grupos de cateteres. Entretanto, o CCIP de duplolúmen de poliuretano apresentou média de tempo de permanência maior comparado ao dispositivo de monolúmen de silicone. / Introduction: Central venous access devices have become vital to the recovery and survival of newborns and infants hospitalized in the Neonatal Intensive Care Unit (NICU). The peripherally inserted central catheter (PICC) has been widely used to supply the therapeutic demands of critically ill newborns. Innovation in the PICC devices have been available, made from biocompatible materials such as silicone and polyurethane, with single or double lumen. Objective: To analyze the relationship between the type of peripherally inserted central catheter device (silicone single lumen or polyurethane double lumen) used in neonates and infants with the reasons for their removal. Method: prospective cohort study consisting of neonates and infants undergoing installation of PICC devices, admitted at the NICU of a private hospital in the city of São Paulo in the period from July 1st, 2010 to June 30, 2011. The neonates and infants were enrolled at the time of catheters installation and followed up until PICC device removal. The research project was examined and approved by the Institutional Research Ethics Boards where the study was carried out (Protocol number 219/2010). Results: Data from 270 PICC devices installed in 213 neonates, 189 (70%) silicon single lumen catheter and 81 (30%) with polyurethane double lumen catheter devices, were analysed. The distribution of demographic, clinical, therapeutic and cathers insertion procedure variables were homogeneous between the two groups of catheters, except for the variables: previous diagnosis of septicemia (p=0,0210) and difficulty on the progression of the catheter during the catheter instalation (p=0,0296). However, the p value for homogeneity test for the odds ratio for the diagnosis of septicemia and the difficulty of catheter progression, no have statistical difference, respectively p=0,955 and p=0,400. The rate of incidence density (ID) for non-elective silicon single lumen catheter removal was 34,8 per 1.000 catheter-days and for the polyurethane double lumen catheter was 32,8 per 1.000 catheter-days. Difference statistically significant, p=0,0005, in the average of length of stay between the two types of catheters was found, the polyurethane double lumen was largest, 14 days, silicone single lumen was 10 days. However, it is not possible to state that the rate of incidence density between the catheters is different when estimated by the Kaplan Meier method survival curve of the catheters with non-elective removal. The survival curves of both catheters overlap in 20th to 25th days, and the logrank value, 0,45, indicates no statistical difference in the non-elective removal catheters incidences between the two types of catheters. Thus, the statistical hypothesis in the length of stay of non-elective removal between both catheters can not be rejected, not confirming the theoretical hypothesis of this study. Conclusion: The results of the study indicate that there is no statistically significant difference in the incidence rates of non-elective removal between the two types of catheters. However, the polyurethane double lumen catheter had higher length of stay mean compared to the silicone single lumen catheter.
124

Análise da relação entre a posição anatômica da ponta do cateter CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos / Analysis of the relation between anatomical location of PICC tip and the reason for the removal of the device in a cohort of neonates

Costa, Priscila 24 November 2011 (has links)
Introdução: O uso do Cateter Central de Inserção Periférica (CCIP) vem sendo cada vez mais frequente em neonatos internados em Unidades de Terapia Intensiva Neonatal (UTIN) em razão da necessidade de um dispositivo de acesso venoso seguro para infusão de drogas irritantes e nutrição parenteral. Detalhes técnicos do CCIP, especialmente a posição anatômica de sua ponta são descritos como fatores de risco para complicações que podem culminar em remoção não eletiva do dispositivo. Objetivo: analisar a relação entre a posição anatômica da ponta do CCIP e o motivo de remoção do dispositivo em uma coorte de neonatos. Método: coorte concorrente, composta por neonatos submetidos à instalação do CCIP, internados em UTIN de um hospital privado da cidade de São Paulo no período de 31 de agosto de 2010 a 01 de julho de 2011. Os neonatos foram incluídos no estudo no momento da instalação do cateter e acompanhados durante a permanência do dispositivo. O projeto de pesquisa foi apreciado e aprovado pelo Comitê de Ética em Pesquisa da instituição, campo do estudo (Processo 238/2010). Resultados: foram analisados dados referentes a 237 CCIPs, dos quais, 207 (86,9%) tiveram posicionamento central da ponta (grupo central) e 30 (12,5%) posição não central da ponta (grupo não central). Nos grupos central e não central, as médias da idade gestacional corrigida, idade pós-natal e peso foram, respectivamente: 34,1 semanas e 33,8 semanas; 9,9 dias e 10,4 dias; 1.936,8 gramas e 1.867 gramas, com homogeneidade entre os grupos, exceto em relação ao diagnóstico de afecção cardíaca, com maior proporção no grupo com cateter não central (p=0,0472). O sitio de inserção, tipo de cateter e terapia intravenosa instituída foram semelhantes entre os grupos. A maioria dos CCIPs (62,3%) foi removida eletivamente. A incidência de remoção não eletiva do CCIP foi maior entre os cateteres não centrais (43,3%), em comparação aos centrais (36,7%) não apresentando diferença estatisticamente significante entre os grupos (p=0,4842). O risco relativo de remoção não eletiva foi 1,18 (IC 95%: 0,76-1,84) vezes maior para os cateteres não centrais. Os principais motivos de remoção não eletiva nos cateteres centrais foram obstrução, ruptura e suspeita de infecção de corrente sanguínea relacionada a cateter, e nos cateteres não centrais foram: tração acidental, suspeita de infecção de corrente sanguínea relacionada a cateter e extravasamento. Houve diferença estatística significante quanto à incidência de extravasamento nos cateteres não centrais em relação aos centrais (p=0,0092). A taxa de incidência (TI) de extravasamento foi 0,8 por 1.000 cateteres-dia em cateteres centrais e 10,2 por 1.000 cateteres-dia nos cateteres não centrais. As médias do tempo de permanência dos cateteres não centrais e centrais foram respectivamente de 9,8 dias e 11,7 dias sem diferença estatisticamente significante (p=0,1627). Conclusão: Os achados sugeriram não haver associação entre o posicionamento não central da ponta do CCIP e a ocorrência de remoção não eletiva do cateter. Entretanto, há necessidade de avaliação permanente do neonato quanto aos sinais de extravasamento / Background: The use of Peripherally Inserted Central Catheters (PICC lines) has become common in neonates admitted to Neonatal Intensive Care Units (NICU), due to the necessity of safe intravenous access for irritant drugs and parenteral nutrition. Some technical details of the PICC, especially the anatomical location of its tip are described as risk factors for complications leading to nonelective removal of this device. Aim: Analyze the relation between anatomical location of the PICC tip and the reason for the removal of the device. Methods: Prospective cohort, composed of neonates who underwent placement of the PICC, admitted to a private NICU in the city of São Paulo, from 31 August 2010 to 1st July 2011. The infants were enrolled after successfully catheter insertion and they were followed up until its removal. The research project was appraised and approved by the Ethics Committee of the institution, (Case 238/2010). Results: Data from 237 PICCs were analyzed, 207 (86.7%) were central in tip location (central group), and 30 (12.5%) were noncentral in tip location (non central group). At central and noncentral groups, the means of corrected gestational age, postnatal age and weight were respectively: 34.1 weeks and 33.8 weeks, 9.9 days and 10.4 days, 1936. 8 grams and 1.867 grams, both groups are homogeneous, except for the diagnosis of heart disease, with the highest proportion in the noncentral group (p=0.0472). The site of insertion, type of catheter and intravenous therapy were similar in both groups. Most of PICCs (62.3%) was removed electively. The incidence of nonelective removal was higher among noncentral catheters (43.3%) compared to central (36.7%) with no statistical significant difference (p = 0.4842). The noncentral group had a 1.18-fold increased risk of nonelective removal compared to central catheters. The main reasons for nonelective removal at the central group were obstruction, rupture and suspicion of catheter-related bloodstream infection, and at the noncentral group were accidental dislodgment, suspicion of catheter-related bloodstream infection and extravasation. There was a statistically significant difference in the incidence of extravasation at the noncentral group compared to central group (p=0.0092). The extravasation rate was 0.8 per 1.000 catheter-days at central group and 10.2 per 1.000 catheter-days at noncentral group. The catheter indwelling time at noncentral and central catheters were respectively 9.8 days and 11.7 days with no statistically significant difference (p=0.1627). Conclusion: The results suggested no association between noncentral tip location of the PICC and the occurrence of nonelective removal of the catheter. However, a continuous assessment of the neonate for the signs of extravasation is needed.
125

Detecção de pneumotórax em tempo real através da tomografia de impedância elétrica / Real-time detection of pneumothorax using electrical impedance tomography

Costa, Eduardo Leite Vieira 18 June 2008 (has links)
Introdução: Pneumotórax é uma complicação comum em pacientes sob ventilação mecânica. Se não reconhecido, tende a aumentar de volume e pode levar ao colapso cardiovascular. Os métodos utilizados para seu diagnóstico caracterizam-se por baixa sensibilidade (radiografia) ou envolvem transporte potencialmente arriscado à tomografia de raios X. A tomografia de impedância elétrica (TIE) é um método não invasivo que permite monitorização da ventilação em tempo real. O método é baseado na construção da imagem de uma seção transversal das condutividades torácicas através de eletrodos dispostos ao redor do tórax. A TIE correlaciona-se muito bem com as alterações regionais do conteúdo de ar dentro do tórax. Por ter baixo custo, não ser invasiva e ter alta sensibilidade às alterações da ventilação e aeração pulmonar, a TIE é um método promissor para a detecção de pneumotóraces em situações de alto risco. Os objetivos deste estudo foram: 1) caracterizar as alterações na TIE relacionadas ao aparecimento de pneumotórax; 2) desenvolver um algoritmo para detecção automática de pneumotóraces e 3) avaliar prospectivamente a sensibilidade e especificidade deste algoritmo. Métodos: Foram realizados experimentos em 39 porcos (peso médio 31,0 Kg ± 3,2 desvios-padrão). Os animais foram sedados e submetidos à ventilação mecânica. Os dados de TIE foram adquiridos através de um tomógrafo de impedância desenvolvido por nosso grupo (Laboratório de Pneumologia Experimental, Escola Politécnica da Universidade de São Paulo e Dixtal Biomédica Ltda., São Paulo, Brasil), capaz de produzir 50 imagens relativas por segundo. Um primeiro grupo de dez animais foi submetido à drenagem torácica com indução progressiva de pneumotórax através do dreno (de 0 a 500 mL). No grupo seguinte, induzimos lesão pulmonar através de lavagem com salina em oito animais e os submetemos a mudanças progressivas de PEEP. Essas duas primeiras etapas foram utilizadas para a construção de um detector automático de pneumotórax baseado na TIE que foi testado prospectivamente em outros 21 animais. Resultados: A TIE apresenta alterações bem definidas relacionadas ao surgimento de pneumotórax, caracterizadas por aumento da impedância média e diminuição da amplitude da impedância concentrados no quadrante de interesse. Por outro lado, os achados na TIE durante mudanças bruscas de PEEP se distribuíram homogeneamente nos quatro quadrantes. A TIE apresentou alterações significativas mesmo com os menores volumes de ar injetados (20 mL), enquanto as demais variáveis monitorizadas foram pouco sensíveis ao surgimento do pneumotórax. A pressão arterial teve uma pequena queda com volumes superiores a 500 mL, e a pressão parcial de oxigênio arterial diminuiu somente com volumes maiores que 100 mL. Na fase prospectiva do protocolo, a TIE mostrou sensibilidade de 100% e especificidade de 95% para a detecção de pneumotóraces. A localização do pneumotórax foi identificada corretamente em todos os casos. Conclusão: A TIE apresenta alterações reprodutíveis relacionadas ao aparecimento de ar no espaço pleural caracterizadas por aumento da impedância média e diminuição da amplitude de impedância. Foi possível criar um algoritmo baseado nessas alterações capaz de detectar precoce e precisamente pneumotóraces em situações de risco. O processo de detecção é automático e em tempo real. / Introduction: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to: 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Methods: prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: 39 anesthetized mechanically ventilated supine pigs (31.0 ± 3.2Kg, mean ± standard deviation). Interventions: In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 up to 500 mL) through chest tubes, or we applied large PEEP increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or pre-injured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Results: primary EIT relative images were acquired on-line (50 images/second) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20mL could be detected with a sensitivity of 100% and specificity 95% and easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers. Their location was correctly identified in all cases, with a total delay of only 3 respiratory cycles. Conclusion: We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
126

Parecer técnico-científico: uso do conector sem agulha para sistema fechado de infusões vasculares / Technical-scientific opinion: use of the needleless connector for a closed vascular infusion system

Roque, Simone Cristina da Silva 23 February 2018 (has links)
Submitted by SIMONE CRISTINA DA SILVA SANTOS (simoneenfer2009@gmail.com) on 2019-01-31T10:36:29Z No. of bitstreams: 1 SIMONE CRISTINA DA SILVA ROQUE.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2019-01-31T10:54:03Z (GMT) No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) / Made available in DSpace on 2019-01-31T10:54:03Z (GMT). No. of bitstreams: 1 roque_scs_ms_bot.pdf: 1347038 bytes, checksum: 9722d99fa9ab996c4b434e523d42e4dd (MD5) Previous issue date: 2018-02-23 / Introdução: A terapia intravenosa é um procedimento rotineiro nas instituições de saúde, requerendo, portanto, acessórios que favoreçam a realização da técnica. Dentre eles destacam-se os conectores para acesso ao sistema de infusão, uma inovação tecnológica com potencial influência nos resultados das infecções nosocomiais. Objetivo: Avaliar a evidência científica disponível sobre o uso do conector sem agulha para sistema fechado de infusões vasculares em pacientes hospitalizados em instituições de saúde. Metodologia: Foi realizada uma busca até 01 de agosto de 2017 nas bases de dados The Cochrane Library, EMBASE, PubMed e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). Foram incluídos estudos de Revisões Sistemáticas (RS) e Ensaios Clínicos Randomizados (ECR). Não houve restrição de idioma e ano de publicação do artigo. Os resultados das bases de dados foram agrupados e eliminados os estudos em duplicatas. Em seguida, aplicados os critérios de elegibilidade para os títulos e resumos, restando 23 estudos para leitura completa. Após leitura dos artigos na íntegra, foram selecionados 3 estudos que comparassem os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema aberto e os conectores sem agulha para acesso por sistema fechado e oclusores/conectores convencionais por sistema fechado. Resultados: Para os desfechos infecção de corrente sanguínea relacionada ao cateter, colonização da ponta de cateter e colonização/contaminação da entrada de hub, não foram encontradas diferenças significativas entre os grupos. Conclusão: Considerando as evidências científicas, a recomendação da tecnologia avaliada é incerta para redução das infecções hospitalares. / Introduction: Intravenous therapy is a routine procedure in health institutions, requiring, therefore, accessories that favor the performance of the technique. Among them, the connectors for access to the infusion system, a technological innovation with potential influence on the results of nosocomial infections, stand out. Objective: To evaluate the available scientific evidence on the use of the needleless connector for closed system of vascular infusions in patients hospitalized in health institutions. Methodology: A search was performed until August 1, 2017 in the databases The Cochrane Library, EMBASE, PubMed and Latin American and Caribbean Literature in Health Sciences (LILACS). We included studies of Systematic Reviews (RS) and Randomized Clinical Trials (RCTs). There was no language restriction and year of publication of the article. The results of the databases were grouped and the duplicate studies were eliminated. Then, the eligibility criteria for the titles and abstracts were applied, leaving 23 studies for complete reading. After reading the articles in full, 3 studies comparing needleless connectors for closed system access and conventional open system occluders / connectors and needleless connectors for closed system access and conventional closed system occluders / connectors were selected. Results: For catheter-related bloodstream infection, catheter-tip colonization, and colonization / contamination of the hub entrance, no significant differences were found between groups. Conclusion: Considering the scientific evidence, the recommendation of the technology evaluated is uncertain for the reduction of hospital infections.
127

Cateterismo central por inserção periférica em UTI neonatal de nível terciário: incidência de complicações e fatores de risco associados / Percutaneously inserted central catheter in neonatal intensive care unit tertiary level: incidence of complications and associated risk factors

Neusa Keico Sakita 29 September 2009 (has links)
O cateter central de inserção periférica (PICC) é um dispositivo com utilização crescente nas Unidades de Terapia Intensiva Neonatal (UTIN). Objetivos Caracterizar a incidência de complicações e os fatores de risco associados à passagem do PICC em recém-nascidos pré-termo (RNPT) internados em uma UTIN de nível terciário. Casuística e Métodos: Foram estudados 128 recémnascidos pré-termo internados na Unidade de Cuidados Intensivos Neonatal (UCINE) do Instituto da Criança do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo no período de janeiro de 2004 a julho de 2007. O estudo foi prospectivo tipo coorte não comparado realizado através da coleta de dados dos RNPT obtidos dos prontuários e pela coleta de informações de um formulário preenchido pelo profissional responsável pela inserção do cateter. A média da idade gestacional foi de 32,2 semanas e o peso médio dos RNPT foi de 1336 gramas (g). Resultados: Dos 128 pacientes estudados, 68 (53,1%) eram do sexo feminino. Com relação ao diagnóstico admissional dos RNPT, a doença das membranas hialinas esteve presente em 44 (34,4 %), desconforto respiratório não classificado em 28 (21,9%), risco infeccioso em 23 (18%), malformação digestiva em 18 (14%) foram os mais comuns. O número total de PICC inseridos foi de 148, sendo que 114 (89%) dos neonatos receberam um cateter, nove (7%) dois, quatro (3%) receberam três cateteres e um recebeu quatro cateteres. A proporção de sucesso da punção venosa em uma tentativa foi de 49,3%, duas tentativas 27,7% e três tentativas 12,8 %. A veia safena magna foi a mais utilizada (70,9%) para as inserções. O tempo médio de permanência do cateter foi de 19,8 dias com um mínimo de um dia e o máximo de 65 dias. As principais complicações observadas foram colonização do cateter(17,3%), quebra do conector e deslocamento(17,7%) (obstrução (6,8%), edema/infiltração (10,1%) ; Os principais preditores de complicações foram: idade gestacional e indicação do cateter pela necessidade de politerapia; O principal motivo da retirada do PICC foi término do tratamento em 47(31,8%), complicações em 75(50,6%) ou devido a morte do paciente em 26(17,6%). Conclusões: O número de cateteres insertados funcionou como indicador de experiência. Quando se excluiu das complicações a quebra mecânica do cateter, não relacionado aos cuidados, a probabilidade de complicação mostrou-se 1,64 vez mais provável antes da habilitação do que após a mesma. A idade à inserção, ou idade cronológica, mudou significantemente do primeiro (2004-5) para o segundo período de estudo (2006-7): 13,2 para 4,8 dias, respectivamente. A diferença de 8,4 dias na indicação do cateter pelos médicos neonatologistas provavelmente se deveu a maior segurança com o procedimento e a competência dos enfermeiros envolvidos com a passagem do cateter / The percutaneously inserted central catheter (PICC) is a device with increased use in Neonatal Intensive Care Units (NICU). Objectives Describe the incidence of complications and associated risk factors with the insertion of the PICC in preterm infants (PTI) admitted to NICU. Material and Methods: This was a non comparative prospective cohort study by collecting data from PTI hospitalized in a referral Neonatal Intensive Care Unit (NICU) of Child\'s Institute of the Hospital das Clinicas, Faculty of Medicine, University of São Paulo. Data were obtained from information registered in patients medical records and from a filled form by the professional in charge the insertion of the catheter. From January 2004 to July 2007, 128 preterm newborns hospitalized in NICU were included in this study. The average gestational age was 32.2 weeks and the average weight was 1336 grams. Results: Of the 128 patients studied, 68 (53.1%) were female. The most prevalent admission diagnoses were the hialine membrane disease in 44 (34.4%), unclassified respiratory distress in 28 (21.9%), infectious risk in 23 (18%), gastrointestinal malformation in 18 (14%). The total number of PICC inserted was 148, 114 neonates (89%) received just one catheter, nine (7%) two, four (3%) three catheters and one received four catheters. The average frequency of successful first venipuncture attempt was 49.3%, two attempts in 27.7% and three attempts in 12.8%. The saphenous vein was the most frequently used (70.9%) for the insertions. The mean duration time of catheters was 19.8 days and the minimum time was one day and maximum time was 65 days. The most frequent complications observed were colonization of the catheter (17,3%), break the connector and dislocation (17.7%) obstruction (6.8%), edema / infiltration (10.1%). The most probable predictors of complications were gestational age and indication of catheter by the need for polytherapy. The main reason for catheter removal were end complication in 68 (46,1%), end of treatment, 54 (36,4%) or death in 26 (17.5%). Conclusion: The number of catheters inserted was an indicator of work experience. When were excluded the complications of mechanical breakage of the catheter, not related to care, but the possible poor quality of the product, the likelihood of complications proved to be 1.64 times more frequent than after it. The age at insertion, or chronological age, changed significantly in the first (2004-5) for the second study period (2006-7): 13.2 to 4.8 days, respectively. The difference of 8.4 days in the indication of the catheter by doctors is probably due to their confidence with the procedure and competence of nurses involved with the insertion of the catheter
128

Adesividade e irritação cutânea do filme transparente gel de clorexidina em pacientes submetidos ao transplante de células tronco hematopoiéticas / Adhesiveness and skin rash related to the transparent film dressing with chlorhexidine gel applied to patients submitted to hematopoietic stem cell transplantation

Bruna Nogueira dos Santos 21 September 2015 (has links)
O Transplante de Células-Tronco Hematopoéticas (TCTH) trata-se da substituição das Células-Tronco Hematopoéticas (CTH) doentes de um indivíduo por CTH normais com o objetivo de normalizar a hematopoese do receptor. O cateter venoso central (CVC) tornou-se indispensável para viabilizar tal terapêutica pela segurança na infusão das CTH e dos quimioterápicos. Para o TCTH são utilizados cateteres do tipo Hickman ou duplo lúmen, ambos de longa permanência. O curativo adesivo utilizado no sítio de inserção do cateter é essencial para a fixação do cateter, proteção contra agentes externos e prevenção de infecção. Há forte evidência clínica no uso do filme transparente gel de clorexidina (CHX) como uma alternativa no controle de infecções relacionadas ao cateter. A adesividade deste curativo confere-lhe uma possível permanência de até sete dias aderido à pele, o que evita repetidas aplicações e remoções do curativo, diminui a frequência na manipulação do cateter, a ocorrência de infecção e irritação cutânea local. Observa-se que a adesividade do curativo nem sempre permite a permanência por sete dias, sendo necessárias trocas não planejadas, podendo causar lesões à integridade cutânea. Neste estudo, objetivou-se avaliar a adesividade e a irritação cutânea do filme transparente gel de CHX aplicado no sítio de inserção do CVC por meio de um estudo transversal, prospectivo, realizado em um hospital público de ensino, no período de novembro de 2013 a junho de 2014, com crianças e adultos de ambos os sexos com doenças autoimunes ou onco-hematológicas submetidos ao TCTH. A amostra desta pesquisa foi constituída por 25 pacientes. Onze (44%) apresentaram irritação cutânea caracterizada por perda de pele de extensão <=0,5cm, perda de pele de extensão > 0,5cm, placa eritematosa e vesículas. Destes, seis tiveram necessidade de suspensão do uso do curativo. A pele fragilizada devido ao uso de agentes quimioterápicos pode aderir fortemente ao curativo adesivo, sendo desprendida com o mesmo quando este é removido. A perda da integridade cutânea com remoção da camada protetora da pele facilita a entrada de microrganismos aumentando a susceptibilidade a infecções em pacientes imunossuprimidos. Em 55,6% das avaliações foi observado desprendimento do curativo e a região da fenda foi onde mais ocorreu desprendimento (43,4%). Esta é uma região da margem do curativo, assim denominada por possuir uma abertura no adesivo onde são posicionadas as vias do cateter. Infere-se que devido à mobilidade do paciente e manuseio das vias do cateter, com o passar dos dias, essa região da borda do curativo apresenta maior desprendimento. Em 8,4% das observações havia bolha de ar no gel de clorexidina envolvendo o sítio de inserção do cateter. A bolha de ar no gel de clorexidina significa que este não está em contato com a pele do paciente o que é preocupante quando envolve o sítio de inserção do cateter, pois a CHX não está exercendo sua função antisséptica neste local, onde há possibilidade de migração extra- lúmen de microrganismos à corrente sanguínea / Hematopoietic stem cell transplantation (HSCT) involves the replacement of sick hematopoietic stem cells (HSC) from an individual with normal HSC, with the aim to restore the recipient\'s hematopoiesis. Central venous catheters (CVC) have become indispensable to make this therapy feasible due to the safety of infusion of the HSC and the chemotherapeutic agents. In HSCT, long-term Hickman or long-term double lumen catheters are used. The adhesive dressing used in the site of insertion of the catheter is essential for the catheter fixation, protection against external agents and prevention of infection. There is strong clinical evidence on the use of transparent film dressing with chlorhexidine gel (CHX) as an alternative in the control of catheter-related infections. The adhesiveness of this dressing allows it to be used up to seven days once it adheres to the skin, which avoids repeated dressing applications and removals, and reduces the frequency of catheter handling, the occurrence of infection, and local skin rash. However, as observed, the dressing adhesiveness does not always allow it to be used for seven days, and unplanned replacements may be needed, which can cause lesions to the skin integrity. The objective of this study was to evaluate the adhesiveness and skin rash related to the transparent film dressing with CHX gel applied at the site of insertion of the CVC by means of a cross-sectional, prospective study developed at a public teaching hospital, between November 2013 and June 2014, with children and adults of both genders with autoimmune or onco-hematological diseases who were submitted to HSCT. The sample comprised 25 patients. Eleven (44%) presented skin rash characterized by skin loss to an extension of <=0.5 cm, skin loss to an extension of > 0.5 cm, erythematous plaque and vesicles. Of these, six had to interrupt the use of the dressing. Frail skin due to the use of chemotherapeutic agents can adhere strongly to the adhesive dressing, coming off with the dressing at its removal. The loss of skin integrity with the removal of the skin\'s protective layer facilitates the entrance of microorganisms, increasing susceptibility to infections in immunosuppressed patients. In 55.6% of the evaluations, there was dressing detachment, and it was greater in the opening region (43.4%), which is a region in the dressing border with a break in the adhesive where the catheter is placed. Given the mobility of the patient and the handling of the catheter, over the days, this region of the dressing border presents greater detachment. In 8.4% of the observations there were air bubbles in the chlorhexidine gel involving the site of insertion of the catheter. Air bubbles in the chlorhexidine gel means that it is not in contact with the patient\'s skin, which is a cause of concern when the site of insertion of a catheter is involved, since CHX is not exerting its antiseptic function in this location, which can lead to extra-lumen migration of microorganisms to the bloodstream
129

Detecção de pneumotórax em tempo real através da tomografia de impedância elétrica / Real-time detection of pneumothorax using electrical impedance tomography

Eduardo Leite Vieira Costa 18 June 2008 (has links)
Introdução: Pneumotórax é uma complicação comum em pacientes sob ventilação mecânica. Se não reconhecido, tende a aumentar de volume e pode levar ao colapso cardiovascular. Os métodos utilizados para seu diagnóstico caracterizam-se por baixa sensibilidade (radiografia) ou envolvem transporte potencialmente arriscado à tomografia de raios X. A tomografia de impedância elétrica (TIE) é um método não invasivo que permite monitorização da ventilação em tempo real. O método é baseado na construção da imagem de uma seção transversal das condutividades torácicas através de eletrodos dispostos ao redor do tórax. A TIE correlaciona-se muito bem com as alterações regionais do conteúdo de ar dentro do tórax. Por ter baixo custo, não ser invasiva e ter alta sensibilidade às alterações da ventilação e aeração pulmonar, a TIE é um método promissor para a detecção de pneumotóraces em situações de alto risco. Os objetivos deste estudo foram: 1) caracterizar as alterações na TIE relacionadas ao aparecimento de pneumotórax; 2) desenvolver um algoritmo para detecção automática de pneumotóraces e 3) avaliar prospectivamente a sensibilidade e especificidade deste algoritmo. Métodos: Foram realizados experimentos em 39 porcos (peso médio 31,0 Kg ± 3,2 desvios-padrão). Os animais foram sedados e submetidos à ventilação mecânica. Os dados de TIE foram adquiridos através de um tomógrafo de impedância desenvolvido por nosso grupo (Laboratório de Pneumologia Experimental, Escola Politécnica da Universidade de São Paulo e Dixtal Biomédica Ltda., São Paulo, Brasil), capaz de produzir 50 imagens relativas por segundo. Um primeiro grupo de dez animais foi submetido à drenagem torácica com indução progressiva de pneumotórax através do dreno (de 0 a 500 mL). No grupo seguinte, induzimos lesão pulmonar através de lavagem com salina em oito animais e os submetemos a mudanças progressivas de PEEP. Essas duas primeiras etapas foram utilizadas para a construção de um detector automático de pneumotórax baseado na TIE que foi testado prospectivamente em outros 21 animais. Resultados: A TIE apresenta alterações bem definidas relacionadas ao surgimento de pneumotórax, caracterizadas por aumento da impedância média e diminuição da amplitude da impedância concentrados no quadrante de interesse. Por outro lado, os achados na TIE durante mudanças bruscas de PEEP se distribuíram homogeneamente nos quatro quadrantes. A TIE apresentou alterações significativas mesmo com os menores volumes de ar injetados (20 mL), enquanto as demais variáveis monitorizadas foram pouco sensíveis ao surgimento do pneumotórax. A pressão arterial teve uma pequena queda com volumes superiores a 500 mL, e a pressão parcial de oxigênio arterial diminuiu somente com volumes maiores que 100 mL. Na fase prospectiva do protocolo, a TIE mostrou sensibilidade de 100% e especificidade de 95% para a detecção de pneumotóraces. A localização do pneumotórax foi identificada corretamente em todos os casos. Conclusão: A TIE apresenta alterações reprodutíveis relacionadas ao aparecimento de ar no espaço pleural caracterizadas por aumento da impedância média e diminuição da amplitude de impedância. Foi possível criar um algoritmo baseado nessas alterações capaz de detectar precoce e precisamente pneumotóraces em situações de risco. O processo de detecção é automático e em tempo real. / Introduction: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to: 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Methods: prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: 39 anesthetized mechanically ventilated supine pigs (31.0 ± 3.2Kg, mean ± standard deviation). Interventions: In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 up to 500 mL) through chest tubes, or we applied large PEEP increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or pre-injured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Results: primary EIT relative images were acquired on-line (50 images/second) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20mL could be detected with a sensitivity of 100% and specificity 95% and easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers. Their location was correctly identified in all cases, with a total delay of only 3 respiratory cycles. Conclusion: We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
130

Efeito de dois dispositivos de hemostasia na ocorrência de oclusão da artéria após cateterismo cardíaco transradial : ensaio clínico randomizado / Effect of two hemostasis devices in case of artery occlusion after radial cardiac catheterization: a randomized clinical trial

Santos, Simone Marques dos January 2017 (has links)
Evidências favoráveis impulsionaram o uso da técnica transradial nos últimos anos. Estudos originais que apresentam o uso dessa prática apontam baixo risco de complicações locais, maior conforto para os pacientes, possibilidade de mobilização e deambulação precoce após procedimento, diminuição do período de internação hospitalar e redução de custos hospitalares. Entre as complicações possíveis, a mais temida é a oclusão da artéria radial (OAR). Embora seja preocupante essa complicação, ainda não há consenso quanto à avaliação rotineira da patência da artéria antes da alta hospitalar e sua relação com o dispositivo hemostático utilizado. Visando preencher essa lacuna do conhecimento, este estudo foi planejado para comparar o efeito de dois dispositivos de hemostasia após cateterismo cardíaco realizado por acesso transradial na ocorrência de OAR. Foi conduzido um ensaio clínico randomizado (ECR) de dois grupos, aberto, no Laboratório de Hemodinâmica (LH) de um hospital público e universitário da região metropolitana de Porto Alegre, Rio Grande do Sul. O período de coleta foi de novembro de 2015 a outubro de 2016. Foram incluídos pacientes adultos ambulatoriais e internados, submetidos a cateterismo cardíaco diagnóstico e/ou terapêutico por acesso transradial, em caráter eletivo e/ou de urgência. Os participantes foram randomizados em dois grupos: Grupo Intervenção (GI) – hemostasia com dispositivo TR Band; e Grupo Controle (GC) – hemostasia com dispositivo de gaze e bandagem elástica adesiva. O desfecho primário foi a OAR imediata ao procedimento e em 30 dias; os desfechos secundários foram a migração dos padrões das curvas após retirada imediata do dispositivo e em 30 dias, a necessidade de tempo a mais para alcance da hemostasia, as demais complicações vasculares relacionadas ao sítio de punção (sangramento e hematoma) e a presença e intensidade de dor. Foram incluídos 600 pacientes: GI (n=301) e GC (n=299), predominantemente do sexo masculino, com média de idade de 63 ± 10 anos; a OAR imediatamente após a remoção do dispositivo ocorreu em 24 (8%) e 19 (6%), no GI e GC, respectivamente; em 30 dias para um terço da amostra foi de 5 (5%) e 7 (6%), no GI e GC, respectivamente. Para estes dois períodos não foram demonstradas diferenças estatísticas; o tempo de hemostasia adicional, assim como o tempo necessário para outro tipo de compressão, foi significativamente maior no GI, p=0,006 e p<0,001, respectivamente; pacientes de ambos os grupos mantiveram um padrão e migração de curvas semelhantes na avaliação pré procedimento, imediatamente após a retirada dos dispositivos e em 30 dias; o sangramento menor foi significativamente maior no GI, quando comparado ao GC, 67 (22%) vs. 40 (13%), respectivamente, p = 0,006; o hematoma foi semelhante entre os dois grupos. O relato de dor foi similar entre os grupos, e a intensidade relatada foi moderada. Os resultados deste estudo permitem concluir que a incidência de OAR foi semelhante entre os grupos TR Band e bandagem elástica adesiva. Os padrões de curva do teste de Barbeau foram semelhantes em todas as avaliações. Pacientes que utilizaram TR Band precisaram de mais tempo adicional de hemostasia assim como mais tempo com outro tipo de compressão. O sangramento menor foi mais incidente no grupo TR Band, enquanto o hematoma foi semelhante entre os grupos. A ocorrência de dor moderada foi semelhante entre os dois grupos. / Favorable evidence increase the use of the transradial technique in recent years. Original studies that address this approach suggest low risk of local complications, greater comfort for patients, the possibility of early mobilization and ambulation after the procedure, a shorter hospital stay and reduced hospital costs. Among the possible complications, the most feared is radial artery occlusion (RAO). Although RAO is of concern, there is still no consensus regarding the routine assessment of radial artery patency before discharge and its relationship to the hemostatic device used. In order to fill this knowledge gap, this study was planned to compare the effect of two hemostasis devices after cardiac catheterization performed by transradial access on the appearance of RAO. A two-group Randomized Clinical Trial (RCT) was conducted at the Hemodynamic Laboratory (HL) of the Hospital de Clínicas of Porto Alegre (HCPA), a public university hospital in the metropolitan region of Porto Alegre, Rio Grande do Sul. The collection period was from November 2015 to October 2016. Adult patients from the outpatient clinic and hospitalized patients undergoing cardiac diagnostic and / or therapeutic catheterization due to transradial access, in an elective and / or emergency manner, were included. Participants were randomized into two groups: intervention group (IG) - hemostasis with TR Band device; Control Group (CG) - hemostasis with gaze device and adhesive elastic bandage. The primary outcome was immediate RAO to the procedure and in 30 days; secondary outcomes were migration of the curvature patterns after immediate device removal and in 30 days, the need for extra time to reach hemostasis other vascular complications related to the puncture site (bleeding and hematoma), and the presence and intensity of pain. A total of 600 patients were included: IG (n=301) and CG (n=299), predominantly males with a mean age of 63 ± 10 years; RAO immediately following device removal occurred in 24 (8%) and 19 (6%), in the IG and CG groups, respectively; in 30 days for a third of the sample was 5 (5%) and 7 (6%) in IG and CG, respectively. For these two periods no statistical difference was demonstrated. The additional hemostasis time, as well as the time required for another type of compression, was significantly higher in IG, p=0.006 and p<0.001, respectively; patients from both groups maintained a pattern of migration of similar curves in the pre-procedure assessment, immediately after the device withdrawal and in 30 days; The lowest bleeding was significantly higher in the IG, compared to the GC, 67 (22%) vs 40 (13%), respectively, p = 0.006; the hematoma was similar between the two groups. The reported pain was similar between the groups, and the reported intensity was moderate. The results of this study allow us to conclude that the incidence of RAO was similar between TR Band groups and adhesive elastic bandage. The standards of the Barbeau test curve were similar in all assessments. Patients who used TR Band required more extra hemostasis time as well as more time with another type of compression. Minor bleeding was more incident in the TR Band group, while the hematoma was similar between the groups. The occurrence of moderate pain was similar between the two groups.

Page generated in 0.1874 seconds