• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 131
  • 64
  • 10
  • 7
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 241
  • 125
  • 73
  • 67
  • 57
  • 55
  • 53
  • 39
  • 38
  • 38
  • 38
  • 37
  • 23
  • 20
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Cateterismo cardíaco: da compreensão do usuário ao planejamento das orientações de enfermagem / Cardiac catheterization: user’s understanding of the nursing planning guidelines.

Teixeira, Tatiane Roberta Fernandes [UNESP] 29 February 2016 (has links)
Submitted by TATIANE ROBERTA FERNANDES TEIXEIRA null (tatianebt@ig.com.br) on 2016-04-27T14:10:26Z No. of bitstreams: 1 mestrado final 2016.pdf: 2224865 bytes, checksum: 8f91df194587a0744ed8ece2327c6d46 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-04-29T18:54:48Z (GMT) No. of bitstreams: 1 teixeira_trf_me_bot.pdf: 2224865 bytes, checksum: 8f91df194587a0744ed8ece2327c6d46 (MD5) / Made available in DSpace on 2016-04-29T18:54:48Z (GMT). No. of bitstreams: 1 teixeira_trf_me_bot.pdf: 2224865 bytes, checksum: 8f91df194587a0744ed8ece2327c6d46 (MD5) Previous issue date: 2016-02-29 / A Organização Mundial da Saúde classificou as doenças cardiovasculares como as principais causas de mortes no mundo, responsáveis por altas taxas de internação e elevados custos hospitalares. A expressividade desses valores tem elevado os investimentos das técnicas e tecnologias utilizadas na elucidação diagnóstica e terapêuticas eficazes com intenção do controle dessas doenças. Esses avanços contribuem para o aprimoramento de estudos realizados em laboratórios de hemodinâmica como o cateterismo cardíaco. Esse exame, considerado padrão ouro no diagnóstico das obstruções coronárias, tem cerca de 80% dos procedimentos ambulatoriais, com a vantagem da redução do tempo de permanência no hospital e a desvantagem de diminuir o tempo de contato com a equipe, contribuindo para falhas na comunicação e interferindo na percepção dos profissionais no que se refere as necessidades e sentimentos do usuário em relação ao procedimento. Diante do exposto, este estudo tem por objetivo compreender o significado e descrever as informações recebidas sobre o cateterismo cardíaco aos usuários de um serviço de hemodinâmica, com vistas a elaborar orientações de enfermagem no pré-procedimento. É um estudo descritivo com abordagem qualitativa, que foi realizado no setor de hemodinâmica, de um Hospital de Ensino do Interior do Estado de São Paulo. Participaram do estudo 31 pacientes adultos que, pela primeira vez, estavam em procedimento de cateterismo cardíaco eletivo os quais aceitaram participar, assinando o Termo de Consentimento Livre e Esclarecido. Os dados foram coletados por meio de entrevista semiestruturada, realizada pela pesquisadora e a análise dos dados foi realizada pelo método de Análise de Conteúdo. Dos discursos dos entrevistados emergiram as seguintes categorias: os usuários conseguem relatar os sintomas e a trajetória que os levaram à realização do cateterismo cardíaco; as informações para o procedimento de cateterismo cardíaco são fornecidas na forma escrita, porém parcialmente assimiladas pelos usuários; os usuários desconhecem o procedimento de cateterismo cardíaco; a realização do cateterismo cardíaco mobiliza sentimentos de ansiedade e os usuários têm esperança de que o cateterismo cardíaco promova mudanças que melhorem a qualidade de vida. Os resultados do estudo permitem concluir que os usuários demonstram conhecimento insatisfatório acerca do cateterismo cardíaco e que as informações recebidas são parcialmente assimiladas, evidenciando a importância da equipe investir em capacitação comunicativa e no planejamento de orientações que fortaleçam os indivíduos na promoção da saúde, esperança e autonomia, além de estimular o reconhecimento das ações de Enfermagem. / The World Health Organization ranked cardiovascular diseases as the leading cause of death worldwide, being responsible for high rates of hospitalization and high hospital costs. These remarkable values have led to high investments in techniques and technology used in laboratory diagnosis and effective treatment in order to control these diseases. These advances contribute to the improvement of studies in hemodynamic laboratories, such as cardiac catheterization. This exam, considered gold standard in the diagnosis of coronary obstructions, amounts to about 80 % of outpatient procedures, with the advantage of reducing the patient's stay in hospital and the disadvantage of reducing the contact time with the team, contributing to failures in communication, and thus interfering with the staff’s perception of the user’s needs and feelings about the procedure. Given the above, this study aims to understand the meaning and describe the information received by the users of a hemodynamic service about the cardiac catheterization in order to prepare pre-procedure nursing guidelines. It is a descriptive qualitative study, which was conducted in the hemodynamic sector of a school hospital in São Paulo State. The study included 31 adult first-time patients who were under elective cardiac catheterization procedure and agreed to participate by signing the Instrument of Consent. Data were collected through a semi-structured interview, conducted by the researcher and data analysis was performed by the content analysis method. From the interviews the following categories emerged: users can report symptoms and the path that led to cardiac catheterization; the information for the cardiac catheterization procedure is provided in written form, but partially assimilated by users; users are unaware of the cardiac catheterization procedure; the cardiac catheterization mobilizes feelings of anxiety and users hope that the cardiac catheterization may promote changes which will improve their quality of life. The study results support the conclusion that the patients have poor knowledge about cardiac catheterization and the received information is partially assimilated, showing the importance for the staff to invest in communication training and planning guidelines which can reinforce individuals in health promotion, hope and autonomy in addition to stimulate the recognition of Nursing actions.
102

Validação clínica dos diagnósticos de enfermagem mobilidade física prejudicada, integridade tissular prejudicada e integridade da pele em pacientes submetidos a cateterismo cardíaco

Costanzi, Angelita Paganin January 2011 (has links)
Introdução: Mobilidade Física Prejudicada é um diagnóstico de enfermagem (DE) prioritário para pacientes submetidos a cateterismo cardíaco. No entanto, para os diagnósticos Integridade Tissular Prejudicada e Integridade da Pele Prejudicada, freqüentemente estabelecidos neste cenário, ainda não há um consenso sobre o mais adequado. Estudos de validação de diagnósticos para pacientes submetidos a procedimentos como cateterismo cardíaco diagnóstico ou terapêutico, permanecem inexplorados. Objetivos: Validar clinicamente as características definidoras dos DE Mobilidade Física Prejudicada, Integridade Tissular Prejudicada e Integridade da Pele Prejudicada em pacientes submetidos a cateterismo cardíaco; e validar seis características adicionais aos diagnósticos em estudo. Métodos: Estudo transversal conduzido em Laboratório de Hemodinâmica no interior do Rio Grande do Sul no período de novembro de 2009 a novembro de 2010. Para a validação clínica (modelo proposto por Fehring) utilizou-se um instrumento com as características definidoras dos diagnósticos em estudo, aplicado por duas enfermeiras peritas. Incluíramse pacientes ≥ 18 anos, ambos os sexos, que realizaram cateterismo cardíaco diagnóstico ou terapêutico eletivo, procedimento por via femoral. Foram consideradas características definidoras validadas aquelas com R> 0,50 (taxa de fidedignidade). O teste Kappa também foi utilizado para avaliar a concordância entre as peritas. Os DE em estudo são baseados na Taxonomia da NANDA-I. Resultados: Incluíram-se 250 pacientes, com idade média 63±12 anos. Foram validadas como características definidoras para Mobilidade Física Prejudicada (1º DE): Amplitude limitada de movimento (R=1), Capacidade limitada para desempenhar as habilidades motoras grossas (R=1) e Dificuldade para virar-se (R=0,80); (2º DE) Integridade Tissular Prejudicada foi Tecido lesado (R=1) e (3º DE) Integridade da Pele Prejudicada foram Invasão de estruturas do corpo (R=1) e Rompimento da superfície da pele (R=1). As demais características dos três diagnósticos foram consideradas não representativas para o cenário em que se desenvolveu o estudo. Foram incluídas características definidoras adicionais para o 1º DE: Desconforto, para o 2º DE: Dor aguda, Hematoma, Sangramento, Rubor e Calor. Pelo Teste Kappa todas foram consideradas com concordância excelente. Conclusão: Para pacientes submetidos a cateterismo cardíaco diagnóstico ou terapêutico eletivo validou-se três características para o 1º DE; uma para o 2º DE e duas para o 3º DE. Pelo teste Kappa seis características adicionadas aos diagnósticos em estudo, obtiveram concordância excelente entre as peritas. / Introduction: Impaired Physical Mobility is a prior nursing diagnosis (ND) in patients who underwent Cardiac Catheterization. However, for ND Impaired Tissue Integrity and Impaired Skin Integrity, which are frequently established in this scenario, an adequate consensus lacks. Studies for diagnoses validation in patients who underwent proceedings such as diagnostic or therapeutic cardiac catheterization remains unexplored. Objectives: To clinically validate the defining characteristics of the following nursing diagnosis: Impaired Physical Mobility, Impaired Tissue Integrity, and Impaired Skin Integrity in patients who underwent Diagnostic or Therapeutic Cardiac Catheterization; to clinically validate the six additional characteristics in the diagnoses under study. Methods: Cross-sectional study carried out in a Hemodynamics Laboratory in the countryside of Rio Grande do Sul, Brazil, from November 2009 to November 2010. For clinical validation (Fehring Model) an instrument was used with the defining characteristics of the diagnoses being studied. The instrument was applied by two expert nurses. The patients had ≥ 18 years old, of both sexes, who underwent elective Diagnostic or Therapeutic CARDIAC Catheterization via femoral vein. Validated defining characteristics were considered when presenting R > 0.50 (reliability index). The Kappa test was also used to validate the agreement between the observers. DE in the study is based on the NANDA-I Taxonomy. Results: For this study, 250 patients were included, mean age 63±12 years-old. As valid defining characteristics were R ≥ 0.80 for Impaired Physical Mobility (1st ND): limited range of motion (R=1), limited ability to perform gross motor skills (R=1), difficulty turning (R=0,80); Impaired Tissue Integrity (2nd ND) was Injured Tissue (R=1); and Impaired Skin Integrity (3rd ND) were Invasion of Body Structures (R=1) and Disruption of the Skin Surface (R=1). Other characteristics of these three diagnoses were considered not representative for the scenario where this study was applied. Defining characteristics were included in the 1st ND (discomfort) and in the 2nd ND (Acute Pain, Bruising, Bleeding, Redness and Warmth). According to Kappa Test, six characteristics of them were considered with excellent agreement. Conclusion: For patients who underwent elective Diagnostic or Therapeutic Cardiac Catheterization, three were validated in the 1st ND; one in the 2nd ND; and three in the 3rd ND. According to Kappa Test, six additional characteristics obtained excellent agreement between the expert nurses. / Introducción: La Movilidad Física Perjudicada es un Diagnóstico de Enfermería (DE) prioritario para pacientes sometidos a cateterismo cardíaco. Sin embargo, para los diagnósticos de Integridad Tisular Perjudicada e Integridad de la Piel Perjudicada aun no existe un consenso que apunte al más adecuado. Estudios de validación de diagnósticos para pacientes sometidos a procedimientos como cateterismo cardíaco diagnóstico o terapéutico aun son poco explorados. Objetivo: Validar clínicamente las características que definen los diagnósticos de enfermería: Movilidad Física Perjudicada, Integridad Tisular Perjudicada e Integridad de Piel Perjudicada en pacientes sometidos a cateterismo cardíaco y validar seis características adicionales a los diagnósticos en estudio. Métodos: Estudio transversal realizado en laboratorio de Hemodinamia en el interior de Rio Grande do Sul en el período de noviembre de 2009 a noviembre de 2010. Para la validación clínica (modelo propuesto por Fehring) se utilizó un instrumento con las características que definen los diagnósticos en estudio, siendo aplicado por dos enfermeras perito. Se incluyeron pacientes mayores de 18 años, de ambos sexos que realizaron cateterismo cardíaco diagnóstico o terapéutico (procedimiento por vía femoral). Fueron consideradas características definidoras validadas aquellas con R>0.50 (valor fidedigno). Fue utilizado el test Kappa para evaluar la concordancia entre los peritos. DE en el estudio se basa en la Taxonomía NANDA-I. Resultados: se incluyeron 250 pacientes, media de edad de 63±12 años. Fueron validadas como características definidoras aquellas con R≥0.80 para Movilidad Física Perjudicada (1ºDE): amplitud limitada de movimiento (R=1), capacidad limitada para desempeñar habilidades motoras complejas (R=1) y dificultad para darse vuelta (R=0.8); Integridad Tisular Perjudicada (2ºDE): tejido lesionado (R=1); Integridad de la Piel Perjudicada (3ºDE): invasión de estructuras del cuerpo (R=1), rotura de la superficie de la piel (R=1). Las demás características de los tres diagnósticos fueron consideradas como no representativas para el escenario donde se desarrolló el estudio. Fueron incluidas características definidoras adicionales para el 1ºDE: incomodidad; para el 2ºDE: dolor agudo, hematomas, sangrado, rubor y calor. Todas ellas mostraron una concordancia excelente al utilizar el test Kappa. Conclusión: Para pacientes sometidos a cateterismo cardíaco diagnóstico o terapéutico, han sido validadas 3 características de 1ºDE, una de 2ºDE, y dos de 3ºDE. Con el test Kappa, seis características adicionales obtuvieron concordancia entre las enfermeras perito.
103

O cuidado de enfermagem e o cateter de Hickman: a busca de evidências / Nursing care and Hickman s catheter: the search for evidence

Renata Cristina de Campos Pereira Silveira 09 June 2005 (has links)
Os pacientes submetidos ao transplante de medula óssea (TMO) necessitam de um acesso venoso seguro para a infusão da medula óssea sem que haja comprometimento do enxerto, assim a implantação de um cateter venoso central é parte da terapêutica, sendo o de Hickman o mais utilizado atualmente; entretanto, sua presença impõe riscos aos pacientes, sendo a infecção, o mais preocupante. A implementação da prática baseada em evidências fundamenta a tomada de decisão do enfermeiro, uma vez que a utilização de resultados de pesquisa é um dos pilares desta abordagem. O presente estudo é uma revisão integrativa da literatura, que teve como objetivo buscar e avaliar as evidências sobre os cuidados de enfermagem relacionados ao cateter de Hickman após a sua implantação, no paciente submetido ao TMO. Para a seleção dos artigos utilizamos as bases de dados Lilacs, Medline, Cinahl e o periódico Bone Marrow Transplantation, e a amostra constituiu-se de 18 artigos. O curativo recomendado é o de poliuretano trocado a cada 7 dias. O método de coleta de sangue observado foi o de descarte, sendo que a dosagem de ciclosporina não deve ser coletada da mesma via onde foi infundida. A redução do número de manipulações do cateter é considerada uma medida eficaz na prevenção e no controle de infecção. As evidências extraídas dos estudos analisados podem auxiliar a implementação de cuidados de enfermagem eficazes relacionados ao cateter de Hickman visando principalmente a melhoria da assistência à saúde. / Patients submitted to Bone Marrow Transplantation (BMT) need a safe venous access for the infusion of bone marrow, without jeopardizing the graft. Thus, the implantation of a central venous catheter is a part of therapy, with Hickman s catheter as the most commonly used type; however, its presence entails risks for the patients, the most preoccupying of which is infection. The implementation of evidence-based practice, with the use of research results as one of its pillars and supports nurses decision making. This integrative literature review aimed to look for and evaluate evidence on nursing care related to Hickman s catheter after its implantation in patients submitted to BMT. Articles were selected from the Lilacs, Medline and Cinahl databases and from the journal Bone Marrow Transplantation. The sample consisted of 18 articles. Polyurethane dressings are recommended, to be changed every 7 days. The observed blood collection method was through discarding, in which the cyclosporine dose should not be collected from the same pathway it was infused in. Reducing the number of catheter manipulations is considered an efficient measure for infection prevention and control. The evidence taken from the studies that were analyzed can be of help in the implementation of efficient nursing care related to Hickman s catheter, mainly with a view to better health care.
104

Determinação da dose de segurança de ácido ascórbico utilizada no tratamento da obstrução de cateter venoso central totalmente implantado / Determining the safe dosage of ascorbic acid used in the treatment of occluded totally implanted central venous catheter

Christiane Inocencio Vasquês 31 January 2011 (has links)
A obstrução de cateter venoso central totalmente implantado (CV-TI) é uma das complicações relacionadas ao seu uso. A recuperação da permeabilidade do CVC-TI é a maneira mais adequada de lidar com esta complicação por se tratar de uma intervenção mais rápida e de menor custo quando comparado com o reposicionamento ou a troca do dispositivo. O ácido ascórbico (AA) vem sendo utilizado em alguns hospitais brasileiros e resultados satisfatórios têm sido obtidos. Estudos in vitro relataram que o AA atua no processo fibrinolítico e pode contribuir para a desobstrução de cateter venoso central de longa permanência. O presente estudo tem por finalidade determinar a dose de segurança do ácido ascórbico para o tratamento da obstrução de cateter venoso central totalmente implantado. Trata-se de ensaio clínico fase II, randomizado em três grupos de tratamento (50mg, 100mg e 200mg de ácido ascórbico), não controlado, conduzido em quatro hospitais brasileiros. Para isso, foram incluídos 21 sujeitos com idade média de 53 anos, a maioria com diagnóstico de câncer de mama. Seis sujeitos obtiveram sucesso com o tratamento proposto, apresentando a desobstrução do cateter. Dentre eles, quatro receberam a dose de 50 miligramas e apresentaram desobstrução completa ou parcial. Em relação ao tempo de desobstrução, três cateteres foram desobstruídos em menos de 60 minutos e três em 60 minutos; entre eles, dois que haviam recebido dose de 50 miligramas. Observou-se, também, que houve relação entre a presença de obstrução anterior e a falha no tratamento com AA. Além disso, aqueles que não tiveram o cateter desobstruído apresentaram intervalo de tempo maior entre o diagnóstico da obstrução e o tratamento da mesma, onde foram identificados 355 dias contra 112 dias naqueles que tiveram o cateter desobstruído. A variável de segurança analisada demonstrou que o ácido ascórbico não induziu reações de hipersensibilidade nesses sujeitos. Conclui-se, portanto, que o tamanho de amostra obtido é insuficiente para afirmar que o ácido ascórbico não seja eficaz na desobstrução de cateter venoso central totalmente implantado. Os resultados encontrados neste estudo nos levam a sugerir, por ora, que a dose de 50mg pode ser testada em um ensaio clínico de fase III, com amostra maior, a fim de validar o uso do ácido ascórbico como um possível agente eficaz no tratamento da obstrução de cateter totalmente implantado. / The occlusion of totally implanted central venous catheter (TI-CVC) is one of the catheterrelated complications. The recovery of the permeability of the TI-CVC is the most appropriate way of dealing with this complication, once it is a faster and less costly intervention than the reposition or change of the device. Ascorbic acid (AA) has been used in some Brazilian hospitals and satisfactory results have been obtained. In vitro studies have reported that AA acts on the fibrinolytic process and can contribute to restore the patency of indwelling central venous catheters. This study aimed to determine the safe dosage of ascorbic acid for the treatment of occluded totally implanted central venous catheter. It is a phase II clinical trial, randomized into three treatment groups (50mg, 100mg and 200mg of ascorbic acid), not controlled, carried out in four Brazilian hospitals. In total, 21 subjects with average age of 53 years were included, most of them diagnosed with breast cancer. Six subjects had success in the proposed treatment, presenting the patency of the catheter. Among them, four were given a dose of 50 milligrams and presented complete or partial patency. Concerning the time of patency, three catheters were cleared in less than 60 minutes and three in 60 minutes, including two that had received a dose of 50 milligrams. Association between the presence of previous obstruction and failure in treatment with AA was also observed. Moreover, those who did not have the catheter cleared presented higher time interval between diagnosis of obstruction and treatment of it, being the intervals 355 days opposed to 112 days for those who had the catheter cleared. The safety variable analyzed showed that ascorbic acid did not induce hypersensitivity reactions in these subjects. It is concluded that the sample size obtained is insufficient to state that ascorbic acid is not effective in clearing totally implanted central venous catheter. Results from this study suggest, for now, that the 50mg dose can be tested in a phase III clinical trial, with larger sample, as to validate the use of ascorbic acid as an agent in the treatment of occluded totally implanted catheter.
105

Caracterização venosa central em crianças internadas em Unidades de Terapia Intensiva pediátrica

Paiva, Bianca Sakamoto Ribeiro [UNESP] 16 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-16Bitstream added on 2014-06-13T20:17:42Z : No. of bitstreams: 1 paiva_bsr_me_botfm.pdf: 258888 bytes, checksum: c116621cfb93317f8c7ac2431a63ec8f (MD5) / A cateterização venosa central é procedimento indispensável para monitorização e tratamento de crianças internadas em unidades de tratamento intensivo. Apesar de disseminada, a utilização de cateteres venosos centrais (CVCs) não é destituída de complicações no momento da inserção e durante sua manutenção. Os objetivos do estudo foram: identificar e quantificar as complicações da cateterização venosa central em crianças internadas em Unidade de Terapia Intensiva Pediátrica (UTIP); identificar os fatores de risco para complicações de inserção e de manutenção e avaliar a necessidade do emprego de medidas de prevenção de complicações e, se necessário, propor modificação das normas e rotinas dos cuidados de enfermagem vigentes. Analisou-se prospectivamente todas as crianças e adolescentes (1 mês a 18 anos de idade) internados na UTIP no período de um ano e que foram submetidos a punção venosa central, no ambiente da unidade. No período, 120 CVCs foram inseridos em 83 crianças. Os residentes (R3) inseriram 84,2% dos CVCs e não houve correlação entre complicações de inserção e manutenção e o profissional que realizou o procedimento.A taxa de sucesso de punção foi alta. A veia mais puncionada foi a jugular interna (79,2%), observando-se que sete tentativas de punção foram mal sucedidas (5,8%). As complicações de inserção mais freqüentes foram mal posicionamento do cateter (14,1%) e punção arterial (10,9%). Mais de três tentativas de punção foi significante para o aparecimento de intercorrências de inserção dos CVCs (p=0,004). Quanto as complicações de manutenção, houve correlação significante para troca do cateter realizada com fio guia (p=0,008), utilização de ventilação mecânica (p=0,025) e tempo de permanência do cateter por mais de sete dias (p=0,001). Sinais flogísticos ocorreram em 68,2% dos locais de inserção... / Central Venous Catheters (CVCs) are considered indispensable in the current medical practice. The aim of this study was to identify and to analyze the complications of the venous catheterization in children admitted in the Pediatric Intensive Care Unit (PICU) - UNESP, and to identify the risk factors for insertion and maintenance of CVCs. Also we aim to evaluate the necessity from prevention measures of complications and if it is necessary to change nursing care routine. During one year we analyzed prospectively 120 CVCs inserted in 83 children aged between 1 month and 18 years. Residents (R3) inserted 84.2% CVCs and no differences were observed between insertion and maintenance complications and the professional responsible for the procedure. Success punction rate was level. Internal jugular vein was the most punctioned vein (79,2%), and only 7 attempts failure (5,8%). Insertion complications more frequent were catheter bad positioned (14,1%) and arterial punction (10,9%). More than three attempts were statistical significant to insertion complication (p=0.004) and CVCs changed with guidewire were significant (p=0.008) to maintenance complications, as well as mechanical ventilation and indwelling time more than 7 days. Local infection was diagnosed in 68,2% and there were two cases of bloodstream-catheter-related infection. Constant observation of the nursing techniques, have showed that 82.3% of the nursing personal did not wash their hands before dressing, verifying association between no washing hands and appearing local infection catheter (p=0,005). Coagulase-negative Staphylococcus was the most common microorganism isolated from the catheters. Results aim the necessity to achieve training and continuing education about nursing care in the maintenance of central venous catheters. Results make clear the necessity to achieve training and continuing education about nursing care in the maintenance of central venous catheters.
106

Comparação dos efeitos do sufentanil e da clonidina administrados por via endovenosa para sedação em pacientes submetidos a cateterismo cardíaco /

Rocha, Anita Perpétua Carvalho. January 2010 (has links)
Orientador: Guilherme Antonio Moreira de Barros / Banca: Eliana Marisa Ganem / Banca: Glória Maria Braga Potério / Banca: Anita Leocádia de Mattos / Banca: Jedson dos Santos Nascimento / Resumo: A sedação para a realização de cateterismo cardíaco, apesar de pouco estudada, tem sido alvo de preocupação de alguns anestesiologistas. Os benzodiazepínicos, os agonistas alfa-2 adrenérgicos e os opióides são comumente utilizados para este fim, entretanto, cada um destes medicamentos possui vantagens e desvantagens. O objetivo deste trabalho é avaliar a eficácia do sufentanil e da clonidina como medicação sedativa em pacientes submetidos a cateterismo cardíaco, comparando o impacto dos mesmos sobre os parâmetros hemodinâmicos e respiratórios apresentados, observando a presença de efeitos colaterais, além da satisfação do paciente e do hemodinamicista durante o exame. Trata-se de um ensaio clínico prospectivo, duplo-cego, randomizado e controlado, que envolveu sessenta pacientes divididos igualmente em dois grupos: GS e GC que receberam respectivamente, 0,1 mcg/kg de sufentanil e 0,5 mcg/kg de clonidina. Estes fármacos foram administrados antes da realização do cateterismo cardíaco. O escore de sedação segundo a escala de Ramsay, a necessidade de utilização de midazolam, os efeitos colaterais, a PAS, a PAD, a FC, a FR e a SpO2 foram registrados a cada cinco minutos, sendo os dados analisados em 06 diferentes momentos. Os grupos foram homogêneos em relação aos dados demográficos e avaliação clínica inicial. O comportamento da PAS, da PAD, da FC e da FR foi semelhante nos dois grupos, entretanto os pacientes do GS apresentaram menor escore de sedação segundo a escala de Ramsay no momento 2 e SpO2 menor que o GC no momento 6. Os pacientes do GS apresentaram maior incidência de NVPO que os pacientes do GC. A satisfação dos pacientes foi maior no GC. Os hemodinamicistas mostraram-se igualmente satisfeitos nos dois grupos. O sufentanil e a clonidina se mostraram efetivos como fármacos sedativos em pacientes submetidos a cateterismo cardíaco. / Abstract: Sedation for cardiac catheterization, although not largely studied, has worried a number of anesthesiologists presently. Not only benzodiazepinic medicine, but also alpha- 2 adrenergic agonist and opioids are commonly used drugs to this end. Each one of these medicaments presents a series of advantages as well as disadvantages. The objective of this paper is to evaluate the effectiveness of sufentanil and clonidine as a sedative medicament to patients submitted to cardiac catheterization, comparing their impact over the hemodynamic and respiratory parameters witnessed, observing the occurrence of side effects, besides patient's and hemodynamicist's satisfaction during the examination. This consists of a prospective, double-blinded, randomized and controlled clinical essay, which involved sixty patients equally divided in two different groups: GS and GC, who, respectively, received 0,1mcg/kg of sufentanil and 0,5 mcg/kg of clonidine. Both administered before cardiac catheterization. The sedation score, according to Ramsay's scale, the necessity of utilizing midazolam, side effects, SAP, DAP, CF and SpO2 were registered every five minutes and data analyzed in six different moments. The studied groups were homogeneous regarding demographic data and initial clinical evaluation. The behavior of SAP, DAP, CF and RF was similar in both groups. However, a lower sedation score regarding Ramsay's scale was observed in GS patients at moment 2 and at moment 6 SpO2 was found to be lower than GC. All GS patients seemed to have had higher incidence of PONV compared to GC patients. Considering patients' satisfaction, it was higher in GC. Hemodynamicists seemed equally satisfied in both groups. Sufentanil and clonidine seemed to have been more effective as sedative medicaments in patients submitted to cardiac catheterization. / Doutor
107

Cateterismo cardíaco da compreensão do usuário ao planejamento das orientações de enfermagem /

Teixeira, Tatiane Roberta Fernandes January 2016 (has links)
Orientador: Eliana Mara Braga / Resumo: A Organização Mundial da Saúde classificou as doenças cardiovasculares como as principais causas de mortes no mundo, responsáveis por altas taxas de internação e elevados custos hospitalares. A expressividade desses valores tem elevado os investimentos das técnicas e tecnologias utilizadas na elucidação diagnóstica e terapêuticas eficazes com intenção do controle dessas doenças. Esses avanços contribuem para o aprimoramento de estudos realizados em laboratórios de hemodinâmica como o cateterismo cardíaco. Esse exame, considerado padrão ouro no diagnóstico das obstruções coronárias, tem cerca de 80% dos procedimentos ambulatoriais, com a vantagem da redução do tempo de permanência no hospital e a desvantagem de diminuir o tempo de contato com a equipe, contribuindo para falhas na comunicação e interferindo na percepção dos profissionais no que se refere as necessidades e sentimentos do usuário em relação ao procedimento. Diante do exposto, este estudo tem por objetivo compreender o significado e descrever as informações recebidas sobre o cateterismo cardíaco aos usuários de um serviço de hemodinâmica, com vistas a elaborar orientações de enfermagem no pré-procedimento. É um estudo descritivo com abordagem qualitativa, que foi realizado no setor de hemodinâmica, de um Hospital de Ensino do Interior do Estado de São Paulo. Participaram do estudo 31 pacientes adultos que, pela primeira vez, estavam em procedimento de cateterismo cardíaco eletivo os quais aceitaram participar, ass... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The World Health Organization ranked cardiovascular diseases as the leading cause of death worldwide, being responsible for high rates of hospitalization and high hospital costs. These remarkable values have led to high investments in techniques and technology used in laboratory diagnosis and effective treatment in order to control these diseases. These advances contribute to the improvement of studies in hemodynamic laboratories, such as cardiac catheterization. This exam, considered gold standard in the diagnosis of coronary obstructions, amounts to about 80 % of outpatient procedures, with the advantage of reducing the patient's stay in hospital and the disadvantage of reducing the contact time with the team, contributing to failures in communication, and thus interfering with the staff’s perception of the user’s needs and feelings about the procedure. Given the above, this study aims to understand the meaning and describe the information received by the users of a hemodynamic service about the cardiac catheterization in order to prepare pre-procedure nursing guidelines. It is a descriptive qualitative study, which was conducted in the hemodynamic sector of a school hospital in São Paulo State. The study included 31 adult first-time patients who were under elective cardiac catheterization procedure and agreed to participate by signing the Instrument of Consent. Data were collected through a semi-structured interview, conducted by the researcher and data analysis was perfor... (Complete abstract click electronic access below) / Mestre
108

Análise comparativa de exposição do operador à radiação entre as técnicas radial, femoral e radial com dispositivo protetor em procedimentos de cardiologia intervencionista

Bienert, Igor Ribeiro de Castro January 2016 (has links)
Orientador: Katashi Okoshi / Resumo: Introdução: A cardiologia intervencionista requer necessariamente um acesso vascular invasivo, sendo esta via de acesso uma escolha do médico operador. Nesta escolha interfere o tipo de procedimento, impacto ao paciente, risco ao profissional e experiência técnica. O acesso via artéria femoral é o mais difundido globalmente e a técnica de acesso pela artéria radial tem sido progressivamente adotada devido ao maior conforto para o paciente, menores taxas de complicações e em alguns cenários, de mortalidade. Um dos focos de interesse crescente é a exposição à radiação ionizante e medidas para minimizar o risco ao paciente e ao profissional. Escassa é a literatura disponível na área e conflitantes são seus resultados. Objetivo: Avaliar os níveis de radiação recebidos pelo médico operador de acordo com as diferentes técnicas de acesso, bem como mapear áreas de escape de radiação. Após essa etapa, o estudo visou desenvolver e validar dispositivo de radioproteção dedicado à técnica radial (TRIPTable) voltado à redução da radiação ao médico operador, comparando o seu impacto à técnica femoral e radial padrão no cenário de pacientes portadores de síndrome coronária aguda randomicamente alocados para cateterismo com intenção de tratamento percutâneo. Métodos: A fase inicial pré-clínica do estudo foi constituída de avaliação em ambiente controlado dos níveis de radiação em pontos pré-especificados de um operador simulado com phantom de água. A fase clínica do estudo foi um ensaio clíni... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Background: Interventional cardiology requires an invasive vascular access, a choice of medical operator. This choice is affected by type of procedure, patient impact, professional risk and technical experience. Interventional procedures via radial technique have progressively increased due to improved patient comfort, lower complication rates, and reduced mortality in some scenarios. One area of interest is radiation exposure and ways to minimizing it. Most studies focusing on patient radiation risk demonstrated conflicting results, and there is no consensus for increased exposure with any technique. Objective: The aim of this study was to evaluate radiological exposure under controlled radial and femoral access simulation tests, mapping radiation paths. After this stage, the study developed a radiological protection device for the transradial technique (TRIPTable), comparing its impact as compared to standard femoral and radial techniques in the setting of patients with acute coronary syndrome randomly assigned for catheterization with intent to percutaneous treatment. Methods: Radiation exposure was simulated under controlled conditions for femoral and radial techniques using a pressurized ionization chamber and water phantom. Different measurement points were defined according to standard positions to simulate radiation received by the operator in the gonads, thyroid, and eyes at different angles during real procedures. The clinical phase of the study is a prospective cli... (Complete abstract click electronic access below) / Doutor
109

Qualidade de vida de pacientes e de cuidadores de pacientes com bexiga neurogênica em uso do cateterismo urinário intermitente / Quality of life of patients and caregivers of patients with neurogenic bladder in use of intermittent urinary catheterization

Laís Fumincelli 04 November 2016 (has links)
Estudo multicêntrico, que teve como objetivo geral compreender as implicações do uso do cateterismo urinário intermitente na qualidade de vida (QV) de pacientes e de cuidadores de pacientes com bexiga neurogênica. Como objetivos específicos, identificar as evidências científicas sobre a QV desses pacientes e/ou cuidadores; caracterizar os pacientes; mensurar a sua QV; analisar as relações entre a QV dos pacientes e os aspectos sociodemográficos, clínicos e do uso do cateter urinário; identificar se realidades geopolíticas e socioculturais distintas interferem na QV dos pacientes; caracterizar os cuidadores e mensurar a sua QV; e analisar as relações entre a QV e os aspectos sociodemográficos e do cuidado. Seguidos os preceitos éticos, o estudo foi realizado com pacientes maiores de 18 anos, com diagnóstico de bexiga urinária neurogênica, usuários do cateterismo urinário intermitente, em um ambulatório de um centro de reabilitação de um Hospital Universitário no interior do estado de São Paulo, no Brasil, e em dois centros de reabilitação, na região central de Coimbra, em Portugal. Para a coleta de dados, foi utilizado um questionário sociodemográfico e clínico, e um questionário de QV, já traduzido e validado no Brasil e em Portugal, chamado World Health Organization Quality Life-bref (WHOQOL-bref). Os cuidadores foram entrevistados no Brasil. Entre os cuidadores, foram incluídos os cuidadores que se corresponsabilizam com o procedimento. Foi utilizado um questionário de caracterização sociodemográfica e dos cuidados e WHOQOL-bref. Os dados foram analisados por estatística descritiva e uso de testes estatísticos com o uso do programa Statistical Package for Social Science (SPSS), versão 22 (Windows). Na amostra de pacientes, brasileiros (n=170) e portugueses (n=52), a maioria era de pessoas solteiras, com ensino fundamental e aposentadas. A lesão medular foi a principal causa do uso do cateter urinário nos dois países. O cateterismo urinário intermitente era realizado pela maioria dos pacientes em mais de quatro vezes ao dia e em um período superior a dez anos. Em relação à QV, os pacientes brasileiros apresentaram escores mais elevados de QV no domínio psicológico e menos elevados no domínio físico. Os pacientes portugueses apresentaram escores mais elevados no domínio psicológico e menos elevados no domínio ambiente. A realização do autocateterismo urinário intermitente para os dois países também foi estatisticamente significativa. Quanto aos cuidadores entrevistados, a maioria (n=74) era do gênero feminino, pessoas casadas e com ensino fundamental. Na análise da QV, os cuidadores apresentaram elevados escores no domínio ambiente e menor escore no domínio psicológico. A QV dos pacientes usuários de cateterismo urinário intermitente pode ser determinada pela melhora dos sintomas urinários, assim como independência, autoconfiança, relações sociais, acesso à atividades laborais e inserção social. Os cuidadores apresentam fragilidades em certos domínios de vida. Cabe aos profissionais de saúde a compreensão desse fenômeno para atuar junto a essa população / Multicenter study, which aimed to understand the implications of the use of intermittent urinary catheterization on the quality of life (QoL) of patients and caregivers of patients with neurogenic urinary bladder. The specific objectives, identify the scientific evidence on the QoL of patients and/or caregivers; characterize the patients; measure their QoL; analyze the relations between QoL of patients and the sociodemographic, clinical and use of urinary catheter aspects; identify whether distinct geopolitical and socio-cultural realities can interfere on the QoL of patients; characterize caregivers and measure their QoL; and analyze the relations between QoL and sociodemographic and care aspects. Followed the ethical precepts, the study was conducted with patients older than 18 years, diagnosed with neurogenic urinary bladder, intermittent urinary catheterization users, at outpatient clinic of a rehabilitation center in the University Hospital in the State of São Paulo, Brazil, and two rehabilitation centers in central region of Coimbra, Portugal. To collect data, a sociodemographic and clinical questionnaire was used, and a QoL questionnaire, translated and validated in Brazil and Portugal, World Health Organization Quality Life-BREF (WHOQOL-bref). The caregivers were interviewed in Brazil. Among the caregivers, were included those were responsible by the procedure. A questionnaire regarding to sociodemographic and care and WHOQOL-bref were used. The data were assessed by means of descriptive statistics and statistical tests using the Statistical Package for Social Sciences (SPSS) version 22 (Windows). Of the Brazilian (n = 170) and Portuguese (n = 52) patients, most were single people, elementary school and retired. Spinal cord injury was the main cause of urinary catheter use in both countries. Most patients performed intermittent urinary catheterization over four times a day and for a period of ten years. Regarding QoL, Brazilian patients had higher scores of QoL in the psychological domain and less in the physical domain. The Portuguese patients had higher scores in the psychological domain and less environment domain. The realization of intermittent urinary catheterization for the two countries was also statistically significant. As for the caregivers interviewed, the majority (n = 74) were female, married people and elementary school. In the analysis of QoL, caregivers showed high scores in the environment domain and lowest score in the psychological domain. QoL of users of intermittent urinary catheterization can be determined by improvement of urinary symptoms, as well as independence, self-confidence, social relations, access to employment and social inclusion activities. The caregivers have fragilities in certain areas of their life. The health professionals should understand this phenomenon and working with this population
110

Validação clínica dos diagnósticos de enfermagem mobilidade física prejudicada, integridade tissular prejudicada e integridade da pele em pacientes submetidos a cateterismo cardíaco

Costanzi, Angelita Paganin January 2011 (has links)
Introdução: Mobilidade Física Prejudicada é um diagnóstico de enfermagem (DE) prioritário para pacientes submetidos a cateterismo cardíaco. No entanto, para os diagnósticos Integridade Tissular Prejudicada e Integridade da Pele Prejudicada, freqüentemente estabelecidos neste cenário, ainda não há um consenso sobre o mais adequado. Estudos de validação de diagnósticos para pacientes submetidos a procedimentos como cateterismo cardíaco diagnóstico ou terapêutico, permanecem inexplorados. Objetivos: Validar clinicamente as características definidoras dos DE Mobilidade Física Prejudicada, Integridade Tissular Prejudicada e Integridade da Pele Prejudicada em pacientes submetidos a cateterismo cardíaco; e validar seis características adicionais aos diagnósticos em estudo. Métodos: Estudo transversal conduzido em Laboratório de Hemodinâmica no interior do Rio Grande do Sul no período de novembro de 2009 a novembro de 2010. Para a validação clínica (modelo proposto por Fehring) utilizou-se um instrumento com as características definidoras dos diagnósticos em estudo, aplicado por duas enfermeiras peritas. Incluíramse pacientes ≥ 18 anos, ambos os sexos, que realizaram cateterismo cardíaco diagnóstico ou terapêutico eletivo, procedimento por via femoral. Foram consideradas características definidoras validadas aquelas com R> 0,50 (taxa de fidedignidade). O teste Kappa também foi utilizado para avaliar a concordância entre as peritas. Os DE em estudo são baseados na Taxonomia da NANDA-I. Resultados: Incluíram-se 250 pacientes, com idade média 63±12 anos. Foram validadas como características definidoras para Mobilidade Física Prejudicada (1º DE): Amplitude limitada de movimento (R=1), Capacidade limitada para desempenhar as habilidades motoras grossas (R=1) e Dificuldade para virar-se (R=0,80); (2º DE) Integridade Tissular Prejudicada foi Tecido lesado (R=1) e (3º DE) Integridade da Pele Prejudicada foram Invasão de estruturas do corpo (R=1) e Rompimento da superfície da pele (R=1). As demais características dos três diagnósticos foram consideradas não representativas para o cenário em que se desenvolveu o estudo. Foram incluídas características definidoras adicionais para o 1º DE: Desconforto, para o 2º DE: Dor aguda, Hematoma, Sangramento, Rubor e Calor. Pelo Teste Kappa todas foram consideradas com concordância excelente. Conclusão: Para pacientes submetidos a cateterismo cardíaco diagnóstico ou terapêutico eletivo validou-se três características para o 1º DE; uma para o 2º DE e duas para o 3º DE. Pelo teste Kappa seis características adicionadas aos diagnósticos em estudo, obtiveram concordância excelente entre as peritas. / Introduction: Impaired Physical Mobility is a prior nursing diagnosis (ND) in patients who underwent Cardiac Catheterization. However, for ND Impaired Tissue Integrity and Impaired Skin Integrity, which are frequently established in this scenario, an adequate consensus lacks. Studies for diagnoses validation in patients who underwent proceedings such as diagnostic or therapeutic cardiac catheterization remains unexplored. Objectives: To clinically validate the defining characteristics of the following nursing diagnosis: Impaired Physical Mobility, Impaired Tissue Integrity, and Impaired Skin Integrity in patients who underwent Diagnostic or Therapeutic Cardiac Catheterization; to clinically validate the six additional characteristics in the diagnoses under study. Methods: Cross-sectional study carried out in a Hemodynamics Laboratory in the countryside of Rio Grande do Sul, Brazil, from November 2009 to November 2010. For clinical validation (Fehring Model) an instrument was used with the defining characteristics of the diagnoses being studied. The instrument was applied by two expert nurses. The patients had ≥ 18 years old, of both sexes, who underwent elective Diagnostic or Therapeutic CARDIAC Catheterization via femoral vein. Validated defining characteristics were considered when presenting R > 0.50 (reliability index). The Kappa test was also used to validate the agreement between the observers. DE in the study is based on the NANDA-I Taxonomy. Results: For this study, 250 patients were included, mean age 63±12 years-old. As valid defining characteristics were R ≥ 0.80 for Impaired Physical Mobility (1st ND): limited range of motion (R=1), limited ability to perform gross motor skills (R=1), difficulty turning (R=0,80); Impaired Tissue Integrity (2nd ND) was Injured Tissue (R=1); and Impaired Skin Integrity (3rd ND) were Invasion of Body Structures (R=1) and Disruption of the Skin Surface (R=1). Other characteristics of these three diagnoses were considered not representative for the scenario where this study was applied. Defining characteristics were included in the 1st ND (discomfort) and in the 2nd ND (Acute Pain, Bruising, Bleeding, Redness and Warmth). According to Kappa Test, six characteristics of them were considered with excellent agreement. Conclusion: For patients who underwent elective Diagnostic or Therapeutic Cardiac Catheterization, three were validated in the 1st ND; one in the 2nd ND; and three in the 3rd ND. According to Kappa Test, six additional characteristics obtained excellent agreement between the expert nurses. / Introducción: La Movilidad Física Perjudicada es un Diagnóstico de Enfermería (DE) prioritario para pacientes sometidos a cateterismo cardíaco. Sin embargo, para los diagnósticos de Integridad Tisular Perjudicada e Integridad de la Piel Perjudicada aun no existe un consenso que apunte al más adecuado. Estudios de validación de diagnósticos para pacientes sometidos a procedimientos como cateterismo cardíaco diagnóstico o terapéutico aun son poco explorados. Objetivo: Validar clínicamente las características que definen los diagnósticos de enfermería: Movilidad Física Perjudicada, Integridad Tisular Perjudicada e Integridad de Piel Perjudicada en pacientes sometidos a cateterismo cardíaco y validar seis características adicionales a los diagnósticos en estudio. Métodos: Estudio transversal realizado en laboratorio de Hemodinamia en el interior de Rio Grande do Sul en el período de noviembre de 2009 a noviembre de 2010. Para la validación clínica (modelo propuesto por Fehring) se utilizó un instrumento con las características que definen los diagnósticos en estudio, siendo aplicado por dos enfermeras perito. Se incluyeron pacientes mayores de 18 años, de ambos sexos que realizaron cateterismo cardíaco diagnóstico o terapéutico (procedimiento por vía femoral). Fueron consideradas características definidoras validadas aquellas con R>0.50 (valor fidedigno). Fue utilizado el test Kappa para evaluar la concordancia entre los peritos. DE en el estudio se basa en la Taxonomía NANDA-I. Resultados: se incluyeron 250 pacientes, media de edad de 63±12 años. Fueron validadas como características definidoras aquellas con R≥0.80 para Movilidad Física Perjudicada (1ºDE): amplitud limitada de movimiento (R=1), capacidad limitada para desempeñar habilidades motoras complejas (R=1) y dificultad para darse vuelta (R=0.8); Integridad Tisular Perjudicada (2ºDE): tejido lesionado (R=1); Integridad de la Piel Perjudicada (3ºDE): invasión de estructuras del cuerpo (R=1), rotura de la superficie de la piel (R=1). Las demás características de los tres diagnósticos fueron consideradas como no representativas para el escenario donde se desarrolló el estudio. Fueron incluidas características definidoras adicionales para el 1ºDE: incomodidad; para el 2ºDE: dolor agudo, hematomas, sangrado, rubor y calor. Todas ellas mostraron una concordancia excelente al utilizar el test Kappa. Conclusión: Para pacientes sometidos a cateterismo cardíaco diagnóstico o terapéutico, han sido validadas 3 características de 1ºDE, una de 2ºDE, y dos de 3ºDE. Con el test Kappa, seis características adicionales obtuvieron concordancia entre las enfermeras perito.

Page generated in 0.1027 seconds