• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 259
  • 65
  • 26
  • 13
  • 6
  • 4
  • 3
  • Tagged with
  • 372
  • 200
  • 115
  • 107
  • 102
  • 98
  • 77
  • 74
  • 67
  • 60
  • 55
  • 41
  • 34
  • 34
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Caractérisation, traçabilité et contrôle qualité des huiles essentielles de lavandes et de lavandins : Apports des signatures chromatographiques et spectroscopiques / Characterization, traceability and quality control of lavender and lavandin essential oils : Contributions of chromatographic and spectroscopic fingerprints

Sakiou, Sofia 08 December 2015 (has links)
Les huiles essentielles (HE) de lavande et de lavandin appartiennent au patrimoine de la région méditerranéenne. Comme tout produit naturel ou synthétique à valeur ajoutée, ces HE doivent être contrôlées pour justifier la qualité du produit. Ce contrôle qualité nécessite la mise en place d'une méthodologie analytique fiable. Dans cette étude, une nouvelle approche utilisant les techniques spectroscopiques et chromatographiques et le traitement de données à l'aide d'outils chimiométriques permet de différencier les HE de lavande et de lavandin par origine variétale. Cette discrimination s'effectue grâce à leur empreinte spectrale ou chromatographique. L’intérêt d’utiliser la chromatographie chirale associée à la détection polarimétrique et de la signature chiroptique acquise a également été étudié. Cette étude nous a permis d’identifier des marqueurs métabolomiques qui sont primordiaux pour caractériser les variétés. Les résultats montrent qu'il est possible de discriminer les HE de lavande et de lavandin selon leurs variétés avec une bonne justesse sur l'ensemble des techniques utilisées. / Lavender and lavandin essential oils (EOs) belong to the heritage of the Mediterranean region. Like any natural or synthetic product with an added value, these EOs must be controlled to justify the quality of the product. This quality control requires the establishment of a reliable analytical methodology. In this study, a new approach using spectroscopic and chromatographic techniques for data processing associated to chemometric tools allows to discriminate lavender and lavandin EOs. This discrimination is carried out thanks to their spectroscopic or chromatographic fingerprints. The interest to use the chiral chromatography combined with polarimetric detection and of acquired chiroptical signature was also studied. This methodology has allowed us to identify metabolomic markers which are paramount to characterize the varieties. The results show that it is possible to discriminate the lavender and lavandin EOs according to their varieties with good accuracy on all of the techniques used.
242

Développement d’une vanne d’injection de liquide pour l’analyse en ligne par chromatographie en phase gazeuse et ses applications dans le domaine du raffinage : étude du comportement et apport des colonnes monolithiques courtes pour la chromatographie en phase gazeuse haute pression / Development of a liquid injection system dedicated to on-line analysis by gas chromatography and its refining applications : study of the behavior and contribution of short monolithic columns in high pressure gas chromatography

Maniquet, Adrien 14 December 2016 (has links)
En milieu industriel, si l'analyse en ligne d'effluents gazeux à l'aide de la chromatographie en phase gazeuse est actuellement réalisée sans difficultés majeure, l'analyse des liquides reste une des principales problématiques à résoudre. En effet, comparée à une analyse réalisée au laboratoire, l'analyse en ligne d'un échantillon liquide permettrait de s'affranchir de l'étape de prélèvement et de préparation avant injection ainsi que des problèmes de contamination et de représentativité de l'échantillon. Des systèmes d'injection de liquide en ligne sont actuellement disponibles, cependant, des difficultés d'injection liées à la discrimination des analytes sont rencontrées. C'est dans ce contexte qu'une vanne dédiée à l'injection des liquides en ligne a été développée, puis validée en laboratoire, et enfin mise en œuvre sur des applications industrielles pétrolières. Un tout autre enjeu, lié entre autres à la réduction des coûts de maintenance et d'installation, ainsi qu'à la compatibilité de systèmes analytiques destinés à l'industrie et aux micro-pilotes, a orienté des développements instrumentaux vers la miniaturisation des systèmes. Un assemblage de différentes briques technologiques a ensuite été réalisé afin d'évaluer la faisabilité d'un système miniaturisé incorporant la technologie d'injection des liquides en ligne. Finalement et toujours dans ce contexte de miniaturisation, des colonnes monolithiques courtes ont été mises en œuvre en chromatographie en phase gazeuse à haute pression, au laboratoire pour commencer, puis sur des effluents industriels gazeux. Elles ont permis de réaliser des analyses très rapides avec une grande efficacité par unité de longueur tout en pouvant agir sur la sélectivité des colonnes grâce à un contrôle de leurs propriétés de surface / In industry, although on-line analysis of gaseous effluents using gas chromatography is carried out without major difficulty, the analysis of liquids remains problematic and is one of the main issues to be solved. Indeed, compared to an analysis carried out in a laboratory, the on-line analysis of a liquid sample would bypass the steps of sampling and preparation prior to injection and would avoid problems of contamination and representativeness of the sample. Systems for injecting liquids on-line are currently available; however, difficulties are encountered, due to the discrimination of analytes. It is in this context that a valve dedicated to the on-line injection of liquids was developed, validated under laboratory conditions and finally implemented in the oil industry. Another issue, related, amongst other things, to the reduction of maintenance and installation costs, as well as to the compatibility of analytical systems for industry and for micro-pilots, steered instrumental developments towards the miniaturization of systems. Different technological bricks were therefore brought together to assess the feasibility of a miniaturized system involving the technology for on-line injection of liquid. Finally, and still in the context of miniaturization, short monolithic columns were implemented in gaseous phase chromatography at high pressure, first in the laboratory and then on industrial gas effluents. They allowed very fast analyses to be performed which had greater efficiency per unit of length while still being able to act on the selectivity of the columns thanks to the control of their surface properties
243

Production, purification et caractérisation d’une gonadotropine chorionique équine recombinante à usage vétérinaire / Production, purification and characterization of recombinant equine chorionic gonadotropin for veterinary use

Jonckeau, Agathe 15 December 2016 (has links)
Des hormones gonadotropiques sont utilisées pour la maîtrise de la reproduction dans le domaine vétérinaire. Ces hormones sont actuellement extraites de tissus ou de fluides animaux. L’entreprise CEVA Santé Animale a récemment fait le choix stratégique de produire ces hormones par voie recombinante. L’objectif de cette étude était d’obtenir une gonadotropine chorionique équine recombinante, reCG, pure et biologiquement active, à partir d’une lignée de cellules mammifères CHO. Les étapes de production, de purification et de caractérisation de l’hormone recombinante ont été développées. Les cellules CHO ont été cultivées en fiole d’Erlenmeyer dans différents milieux de culture. Le suivi de la croissance cellulaire et de la quantité d’hormone produite a permis de sélectionner deux milieux. Le procédé de production, avec ces deux milieux, a été optimisé en bioréacteur en contrôlant les paramètres de culture (température, pH). Les protéines produites dans le surnageant, de ces deux cultures, ont été nommées reCG 1 et reCG 2. Un procédé de purification en 3 étapes a été mis au point pour la reCG 1. Plusieurs résines et conditions chromatographiques ont été criblées en microplaques. Les résines multimodales utilisées ont permis d’éliminer des contaminants majeurs grâce à leur sélectivité. Les agrégats de la reCG ont été éliminés grâce à une résine anionique. Le procédé de purification global a été validé pour la reCG 1 et la reCG 2. Il a permis d’obtenir une pureté de 98 % avec un rendement de 80 %. L’activité biologique de la reCG 1 et la reCG 2, in vitro et in vivo, est comparable à celle de la protéine naturelle. L’activité biologique in vivo des reCG est cohérente avec l’étude réalisée sur les glycosylations des hormones et notamment avec leur degré de sialylation. / The gonadotrophic hormones are used for reproduction control in farming animals. Up to now, these hormones were extracted from animal fluids or tissues. The company CEVA Santé Animal has recently decided to produce recombinant versions of these hormones. The objective of this study was to obtain a pure and biologically active recombinant equine chorionic gonadotropin (reCG) after expression in CHO mammalian cells. The production, purification and characterization steps have been developed. CHO cells were grown in Erlenmeyer flasks with different culture media. Two media were selected based on their cell growth potency and of the amount of reCG produced. By using a bioreactor to control key parameters (temperature, pH), the production process was then optimized. The recombinant proteins that accumulated in the supernatant of the two conditions were called reCG 1 and reCG 2. A 3-steps purification process was then developed using reCG 1. Several resins and chromatographic conditions were screened in microplates. Multimodal resins were used to eliminate the main contaminants thanks to their selectivity. reCG aggregates were efficiently eliminated by a chromatographic step with an anionic resin. The overall purification process was finally validated for reCG 1 and reCG 2. Purity and yield were respectively, 98 % and 80 % for the two reCG. We verified that the in vitro and in vivo activities of reCG 1 and reCG 2 were comparable to those of the CG extracted from natural sources. The in vivo assays also confirmed previous studies showing that the degree of glycosylation of an hormone, and most notably their level of sialytation, is important for their biological activity.
244

Characterization of the sarcolemma in limb-girdle muscular dystrophy / Caractérisation du sarcolemme dans les dystrophies musculaires des ceintures

Kunz, Severine 22 October 2014 (has links)
Les dystrophies musculaires des ceintures (LGMD) sont un groupe hétérogène de dystrophies musculaires à progression lente. Des mutations du gène de la dysferline causent la LGMD de type 2B, mutations dans le gène de la cavéoline-3 (cav-3) causent LGMD de type 1C et des mutations dans le gène anoctamine-5 (ano-5) sont liées aux LGMD. Dans le but d'analyser les mécanismes moléculaires des LGMD et d'étudier les potentielles interactions de la dysferline, de la cav-3 et de l'ano5, des expériences sur des cellules musculaires primaires portant des mutations associées aux gènes DYSF, CAV3 et ANO5 ont été analysées. Les études d'immunomarquage ont montré que la protéine dysferline et la cav-3 sont partiellement colocalisées dans des structures vésiculaires de la membrane plasmique des myotubes primaires humains. La purification biochimique des "detergent-resistant membranes" issus des myotubes différenciés a montré que la dysferline est associée aux " lipid raft " liées aux cytosquelettes d'actine. L'analyse de la microscopie électronique sur les myotubes issus des muscles des patients atteints de LGMD a montré des altérations dans l'abondance des cavéoles à la membrane plasmique qui est en corrélation avec les mutations causant la maladie. L'analyse de l'ultrastructure cellulaire a montré que la dysferline est localisée à la membrane plasmique mais également dans des vésicules cytosoliques. L'immunopurification de ces vésicules contenant de la dysferline a révélé la présence d'environ 500 protéines détectées par LC-MS, ce qui pourrait représenter des protéines structurales vésiculaires, ainsi que des nouveaux partenaires potentiels d'interaction de la dysferline. / Limb-girdle muscular dystrophies (LGMD) are a heterogeneous group of slowly progressive muscular dystrophies with common features such as hyperCKemia and skeletal muscle weakness. Mutations in the dysferlin gene cause LGMD 2B, in the caveolin-3 (cav-3) gene LGMD 1C and in the anoctamin-5 (ano-5) gene LGMD 2L, respectively. In order to reveal the molecular mechanisms underlying LGMD and to investigate the putative interactions of dysferlin, cav-3, and ano5, primary skeletal muscle cell lines with disease-related mutations in DYSF, CAV3, and ANO5 have been analyzed. Immunolabeling studies revealed that dysferlin and cav-3 are partially colocalized in vesicular structures at the plasma membrane. Biochemical purification of detergent-resistant membranes from differentiated myotubes showed that dysferlin is associated with lipid rafts linked to the actin-cytoskeleton. Transmission electron microscopy analysis of myotubes revealed alterations of caveolae abundance at the plasma membrane correlating with disease-causing mutations. Ultrastructural studies revealed localization of dysferlin at the plasma membrane, but also in cytosolic vesicles. These vesicles contained a subset of approximately 500 proteins detected by LC-MS, which might represent vesicular structural proteins, vesicle cargo, and putative new dysferlin interaction partners. Results from this study lead to the conclusion that caveolae play a crucial role in the context of LGMD. Dysferlin and cav-3 seem to be closely linked on structural as well as on functional level. Our results confirm that dysferlin is localized in cytosolic vesicles, which are involved in multiple cellular processes.
245

Procédés de séparation multi colonnes continus : extension à la chromatographie à gradient de solvant / Continuous multicolumn separation processes : extension to solvent gradient chromatography

Tlili, Nawal 11 December 2013 (has links)
Les procédés multi-colonnes de chromatographie ont connu depuis quelques années un développement tel qu'ils sont devenus des standards industriels à toutes échelles, depuis celle des produits pharmaceutiques à haute valeur ajoutée jusqu'à celle des grands intermédiaires chimiques. La spécificité du présent travail consiste à étudier, pour ces procédés, l'influence d'un gradient d'élution. Il s'agit de faire varier au cours du temps la force éluante de la phase mobile. L'objectif est d'augmenter la productivité et le taux de récupération d'un produit à haute valeur ajoutée, tout en répondant à des contraintes de pureté. L'utilisation d'un gradient de solvant, courante en chromatographie analytique, fait l'objet d'un intérêt plus récent en chromatographie préparative. Les applications visées concernent des séparations de mélanges complexes où l'espèce cible a une affinité intermédiaire pour le support solide par rapport à celle des autres espèces, ce qui est souvent le cas lors de la purification de biomolécules issues de matières premières naturelles ou issues des biotechnologies. Dans ce cas, la séparation conduit à trois fractions, des impuretés faiblement retenues, la fraction intermédiaire et des impuretés fortement retenues. Pour notre étude, un mélange modèle, peu coûteux et non toxique, de cinq acides aminés a été choisi. Ces acides aminés ont été choisis en tenant compte de leur caractère apolaire et hydrophobe. Les séparations ont été réalisées par chromatographie en phase inverse. Dans un premier temps, une étude expérimentale, réalisée à l'aide d'une chaîne HPLC, a permis de déterminer les paramètres des isothermes d'adsorption de chaque acide aminé pour différentes teneurs en solvant organique de l'éluant. Une loi empirique a permis de relier le facteur de rétention k à la composition de la phase mobile (K = f (xméthanol)). Un travail de modélisation/simulation, reposant sur l'approche d'une cascade de mélangeurs, a ensuite permis de simuler les séparations obtenues dans le cas d'une seule colonne, puis dans le cas d'un système multi-colonnes. L'utilisation des lois reliant les facteurs de rétention k à la concentration en modifieur a alors permis de réaliser des simulations pour différents gradients de solvants. Dans le cas d'une seule colonne, le gradient a été optimisé en minimisant la durée de la séparation et en respectant une contrainte sur la résolution des pics des 2 espèces les plus difficiles à séparer. Une bonne adéquation a été observée entre les simulations et les résultats expérimentaux obtenus avec un gradient sur une seule colonne. Des expérimentations numériques ont alors été réalisées dans le cas du système multi-colonnes. Les paramètres opératoires optimaux ont été déterminés dans le cas du mélange étudié. Ces réglages seront ainsi utilisés lors de la validation expérimentale qui sera réalisée sur l'unité pilote. Cette unité comporte trois colonnes. Il s'agit d'un procédé séquentiel cyclique. Pour le mode opératoire retenu, chaque cycle comporte 8 étapes. A chaque étape les alimentations et soutirages des différentes colonnes sont modifiées. Pour le soutirage qui correspond à la fraction de l'espèce cible, les critères étudiés seront la pureté et le taux de récupération / Multi-column chromatographic processes have known, for a few years, a development on all scales, from high added value pharmaceutical products to major chemical intermediates. The specificity of the present work is to study the influence of a gradient elution for these processes. It consists in varying the eluent strength of the mobile phase over the time. The aim is to increase the productivity and the recovery ratio of a high added value product, while satisfying the constraints of purity. Solvent gradient is currently used in analytical chromatography and presents a recent interest in preparative chromatography. The applications concern separations of complex mixtures where the target species has an intermediate affinity for the solid phase compared to other species, which is often the case during the purification of biomolecules extracted from natural raw materials or resulting from biotechnologies. In this case, separation leads to three fractions, impurities weakly retained, an intermediate fraction and impurities strongly retained. For our study, a model mixture, inexpensive and nontoxic, of five amino acids was selected considering their nonpolar and hydrophobic character. The separations were carried out by reversed phase chromatography. An experimental study using a HPLC system was first carried out with single-element solution of each amino acid in isocratic mode. This enabled to determine adsorption isotherm parameters. An empirical law giving the retention factor as a function of eluent composition was determined (K = f (xmethanol)). A work of modeling / simulation, assuming linear isotherm and based on the mixed cells approach, permitted to simulate the separations obtained in the case of a one-column process, then in the case of a multi-column system. The use of retention factors laws allowed to carry out simulations for different solvent gradients. In the case of a single column, a simple methodology was developed to calculate the optimal solvent gradient. The gradient was optimized by minimizing the separation time and by respecting a constraint on the peaks resolution of the two species which are the most difficult to separate. A really good adequacy was observed between simulations and the experimental results. Numerical experimentations, executed in the case of the multi-columns process, made it possible, yet, to find the optimal operating parameters in the case of the studied mixture. These settings will be applied in the experimental validation which will be realized on the pilot unit. This unit has three columns. It is a cyclic sequential process. For the selected operating mode, each cycle contains eight steps. At each step, inlets ant outlets streams of different columns are switched. The criteria for the target species fraction are purity and recovery
246

La chromatographie en mode mixte pour la purification de protéines recombinantes à visée santé : caractérisation des interactions impliquées dans les supports de chromatographie HyperCel®, modélisation et applications. / Mixed mode chromatography for recombinant protein purification : characterization of HyperCel® sorbents interactions, modeling and applications

Pezzini, Jérôme 19 December 2011 (has links)
La chromatographie mode mixte représente l’une des plus grandes évolutions de ces dernières années dans le domaine des bioséparations. Cette technique repose sur l'intervention de plusieurs types d'interactions au sein d'un seul et même support. Les résines de chromatographie mode mixte HEA, PPA et MEP HyperCel portent des groupements aliphatiques, aromatiques, thiophiliques ainsi que des groupements aminés protonables en différentes positions. Au moyen d’expériences de chromatographie, à l’aide de protéines standards aux propriétés spécifiques et de mélanges complexes, nous avons isolé ces différentes interactions. Nous avons mis en évidence l’intervention majeure d'au moins deux types d'interactions au sein de ces supports : interactions hydrophobes et électrostatiques. Nous avons pu observer le comportement des résines lors de variations de pH, de force ionique, de types de sels et de tampons ou lors de la présence d'autres composés organiques. Nous avons mis en évidence l'intervention combinée de ces types d'interactions lors des différentes phases de chromatographie. Le comportement des résines mode mixte a révélé des sélectivités particulières et dont le contrôle ciblé à l'aide de l'environnement a permis le développement de méthodes de purification efficaces et originales. Nous avons pu ainsi développer des applications telles que la purification de fragment d’anticorps (Fab’2) à partir de culture de cellules d’insectes, la capture de protéine de type MBP à partir d’extrait bactériens et la capture d’anticorps monoclonaux à partir de cellules de mammifères (CHO), et ainsi améliorer les conditions d’utilisation de la chromatographie en mode mixte. / Mixed mode chromatography is the most innovative technique for bioseparation. Mixed mode resins, as the term suggest, involves multiples types of interaction at the same time. HyperCel mixed mode resins, HEA, PPA and MEP, involve aliphatic, aromatic or thiophilic groups as well as protonable amine located in the spacer arm or as a head group. Using classical chromatographic experiments, standards proteins and complex mixtures, we highlighted the two major types of interactions involved: hydrophobic and electrostatic interactions. We specifically influenced these interactions by modifying the environment in terms of ionic strength, pH, salt types, and other compounds. The combination of these interactions during every phase of a chromatographic process has been demonstrated. Mixed mode resins thus offer unique selectivity that can be controlled by the environment. This allowed us to develop several applications from antibodies fragments capture from insect cells, to the purification of MBP-tagged proteins, through monoclonal antibody capture from CHO cells. We thus enhanced mixed mode chromatography.
247

Elaboration d’un microsystème d’analyse de l’air destiné à la détection rapide d’un développement fongique dans les espaces clos / Elaboration of a rapid and continuous air analyzing macrosystem for fungal contamination detection in enclosed spaces

Joblin, Yaël 12 May 2011 (has links)
Les champignons sont des biocontaminants courants des environnements intérieurs. De nombreuses études ont démontré leur rôle dans la dégradation des supports que ces microorganismes colonisent tels que les matériaux de construction, les ouvrages ou les œuvres d'art. De plus, ces biocontaminants sont susceptibles d'induire des allergies, des infections, des toxi-infections ou encore des irritations. Depuis 2005, une technique de détection de la croissance fongique, basée sur la recherche de traceurs chimiques spécifiques dans l'air, et un indice de contamination fongique (ICF), ont été développés et validés au cours de différentes campagnes de mesures dans l'habitat, les bureaux, les écoles, les crèches… L'objectivation d'une croissance fongique dans un environnement s'appuie sur des prélèvements par adsorption, une analyse chromatographique au laboratoire (GC/MS) et le calcul de l'ICF. Dans le cadre de la surveillance de la qualité microbiologique de l'air des environnements intérieurs, cette thèse a pour ambition de prolonger ces travaux en développant notamment un système de microcapteurs chimiques adapté à la mesure in situ. Cette recherche repose à la fois sur la méthode de détection fongique développée au CSTB et sur l'expertise scientifique et technique de l'ESIEE en matière de miniaturisation d'instruments de mesure, grâce à l'apport des microtechnologies. Le premier axe de cette étude a consisté à identifier expérimentalement les COV du métabolisme fongique spécifiques d'un développement sur des matériaux du patrimoine. Ces molécules ont permis de consolider l'ICF et de définir deux indices spécifiques à la problématique des sites patrimoniaux, validés dans des châteaux, musées, bibliothèques, grottes ornées… Le second axe porte, d'une part, sur la conception la réalisation et la caractérisation des briques élémentaires du microsystème d'analyse, à savoir un module de préconcentration (adsorption TENAX), un module de séparation (microGC) et un module de détection (capteurs polymères) et d'autre part sur les intégrations et pilotage de ces briques / Fungi are common microbial contaminants of indoor environments. Many studies have demonstrated their role in the partial or total degradation of materials they colonize such as building materials, or works of art. Moreover, those microbial contaminants are likely to lead to allergies, infections, poisoning or irritation. Since 2005, a new technique based on researching specific chemical tracers in the air, was developed and validated during different measurement campaigns. This approach is now applied to various indoor environments (houses, offices, schools, child care centers…) and allows the detection of recent and/or hidden contamination. The purpose of this work is to study and characterize a rapid and continuous air analysing microsystem for detection of fungal contamination in closed spaces. This study falls within the field of monitoring air microbiological quality in indoor environments. In addition to the time saved by the absence of any laboratory analysis, this system must provide a permanent monitoring of environments frequented by people, such as museums, schools, hospitals... This research is based both on the fungal detection method developed by CSTB and on scientific and technical expertise of ESIEE : specialised in design and manufacturing of miniaturized analysis systems obtained using microtechnology. The first step of this study was to define the compounds' nature to be detected for different cases of contamination along with the sampling strategy for the system. The second step focuses on the microstructures design and fabrication to be used in microanalytical system based on gas chromatography and the development of a miniaturised analysis system. So the first part of the study consisted in defining specific fungal contamination tracers for heritage conservation sites. This list allowed to reinforce a fungal contamination index for indoor environments and to define two specific indexes designed for heritage conservation sites. The validation of these different indexes allowed checking their compliance with those types of environments (castles, museums, libraries, decorated caves...) by detecting all cases of contamination, along with the control remediation of former contaminated environments. The second part of the study enabled the design and validation of three main modules constitutive of the microanalytical system based on gas chromatography. A miniaturised analysis system based on three modules has been developed
248

Discrimination à l'état solide durant la cristallisation : application à l'ultrapurification du phénanthréne / Discrimination in the solid state during crystallization : application to phenanthrene ultrapurification

Burel, Antoine 20 October 2017 (has links)
La cristallisation est un processus d’auto-assemblement de molécules à partir d’une phase désordonnée (liquide, amorphe ou gazeuse). De façon générale, la miscibilité à l’état solide entre un constituant d’intérêt et son impureté dépendent d’une part, de la structure moléculaire de ces deux espèces, et d’autre part, de la structure cristalline du réseau hôte, c’est-à-dire celui du composé d’intérêt. En cas d’absence de miscibilité, l’optimisation des conditions de cristallisation permet un retrait total de l’impureté du composé visé. Cette thèse vise à démontrer que, lorsque deux molécules sont semblables et que leur structure cristalline est peu dense, des solutions solides de substitutions peuvent se former et empêcher le retrait de l’impureté de l’espèce cible. Inversement, lorsque les impuretés sont très diférentes de l’espèce à purifer, l’absence de solution solide est observée et permet leur élimination totale grâce à une bonne discrimination à l’état solide. Le système du phénanthrène, un composé servant entre autres de base pour la synthèse de composésmorphiniques, a été choisi pour illustrer cette thèse. Diverses méthodes de cristallisation (fusion de zone, co-cristallisation, recristallisation en solution, sublimation-condensation) ont été testées et ont permis, après optimisation et combinaison, l’obtention à l’échelle préparative de phénanthrène pur à plus de 99,999 % en moles, ce qui le place sur l’échelle de l’ultra-pureté (pureté > 99,9 % en moles). / Crystallization is a process during which molecules self assembly from a disordered (liquid, amorphous or gaseous) phase. The miscibility in the solid state between a component of interest and its impurity depends on: (i) their molecular structures, (ii) the crystal structure of the host lattice (namely, that of the component of interest). When no solid solution exists, the impurity can be completely eliminated from the target product after optimization of the crystallization conditions.The present thesis intends to demonstrate that, when two compounds present similar molecular structures with low-density crystal structures, solid solution formation can occur which prevents from their complete separation. Conversely, in case of sufcient dissimilarity, no solid solution is stable and their separation is possible thanks to a large discrimination in the solid state. The phenanthrene system – a model compound used as base for the synthesis of morphine derivatives – was chosen to illustrate this thesis. Several crystallization methods (zone melting, co-crystallization, solvent assisted crystallization and sublimation-condensation) were investigated and permitted, after optimization and combination, to obtain 99.999(9) mole % purity phenanthrene (which is above the ultrapure grade of 99.9 mole %).
249

L'identification et quantification d'additifs dans les carburants et les lubrifiants par HPTLC-MS et techniques de dérivatisation / Identification and quantification of additives in fuels and lubricants by HPTLC-MS and derivatization techniques

Beaumesnil, Mathieu 24 October 2017 (has links)
Les compagnies pétrolières améliorent les propriétés de leurs produits et en particulier des carburants par l’ajout d’additifs. Un large choix de familles d’additifs est disponible, tels que les antioxydants ou les agents antidétonants. Dans ce travail, la chromatographie sur couche mince haute performance (HPTLC) a été utilisée pour quantifier certains additifs dans le gazole sans aucune préparation d’échantillon. L’HPTLC est une technique d’analyse qui est couramment utilisée afin d’analyser et quantifier des composés en mélange. Pour améliorer la détection des polymères et la qualité du signal, des méthodes de dérivatisation ont été utilisées. Afin de confirmer l’identification des composés et obtenir des informations structurales, un couplage direct entre l’HPTLC et la spectrométrie de masse a été développé. Les sources d’ionisation, comme la source DESI(Desorption Electrospray Ionization), la source DART (Direct Analysis in Real Time) et la source MALDI (Matrix Assisted Laser Desorption Ionization) ont été évaluées. Il est apparu que la source MALDI était la plus adaptée pour la désorption des additifs sur plaque HPTLC. Après des essais et optimisations sur différentes phases stationnaires, une méthode HPTLC-MALDI sur phase cellulose a été développée et a permis de détecter les détergents aux teneurs réelles dans le gazole. Parallèlement, l’HPTLC a été couplé pour la première fois à la source ASAP (Atmospheric Solids Analysis Probe). / Oil companies increase the quality of their products such as fuels by using additives. A large variety of additives can be used, such as antioxidants or antiknock agents. In this study, high performance thin layer chromatography (HPTLC) was used to quantify some additive in diesel fuel without sample preparation. HPTLC is an analytical technique used to characterize and quantify compounds in mixtures. To increase polymer detection and signal quality, derivatization methods were used.In order to confirm the analyte identification and to provide structural information, a method based on the direct coupling of HPTLC to mass spectrometry (MS) was developed. Ionization sources such as DESI (desorption electrospray ionization), DART (direct analysis in real time) and MALDI (matrix assisted laser desorption ionization) were evaluated. It appeared that MALDI was the most suitable source to efficiently desorb the additives on HPTLC plate. After several tests and optimizations on different stationary phases and ionization sources, a HPTLC-MALDI method was developed on cellulose and allowed to detect surfactant in diesel fuel at real concentration. At the same time, ASAP (atmospheric solids analysis probe) was coupled for the first time to HPTLC.
250

Apport de la spectrométrie de mobilité ionique couplée à la spectrométrie de masse pour la caractérisation de produits pétroliers formulés / Titre en anglais non fourni

Mendes Siqueira, Anna Luiza 29 May 2018 (has links)
Les produits pétroliers formulés actuels tels que les carburants et les lubrifiants doiventrépondre à des cahiers des charges bien précis pour garantir les meilleures performances,fiabilité et longévité des moteurs tout en limitant l’émission de polluants. Ce travail de thèse porte sur le développement de méthodologies d’analyse pour l’identification d’additifs polymériques dans les gazoles et la caractérisation des polyalphaoléfines. L’analyse des additifs a été effectuée par couplage de la chromatographie liquide, de la spectrométrie de mobilité ionique et de la spectrométrie de masse (LC-IMSMS), l’ionisation étant obtenue par electrospray (ESI). Après ajustement des paramètres expérimentaux, les différents additifs ont été identifiés dans les gazoles sans préparation d'échantillon. Le couplage de la chromatographie liquide aux conditions critiques (LCCC) avec la spectrométrie de masse a également été évalué dans l’objectif d’améliorer la séparation des additifs de la matrice gazole. La caractérisation des polyalphaoléfines (PAO) a été réalisée par couplage IMS-MS associé à la source ASAP (sonde d’analyse de solide à pression atmosphérique) ou la source APPI (photoionisation à pression atmosphérique). En ASAP, outre les ions de pyrolyse, des espèces intactes peuvent être détectées pour les PAO de faible grade. Dans le cas des PAO de haut grade, seuls des ions fragments pyrolytiques ont été détectés, permettant toutefois d’identifier les alpha-oléfines utilisées pour produire les PAOs. En APPI, l’utilisation de solvants halogénés et de toluène, a permis d’observer des espèces intactes pour les PAOs de haut grade via la formation d’adduits halogénés. Le couplage IMS-MS a permis de différencier les polyalphaoléfines par l’étude des temps de dérive et des largeurs de signaux IMS. / Nowadays, formulated petroleum products such as fuels and lubricants must respond toprecise technical requirements to ensure the best performance, reliability and longevity ofengines while limiting the emission of pollutants. This thesis work focused on the development of analytical methodologies for the identification of polymeric additives in diesel fuels and the characterization of polyalphaolefins. The additive analysis was performed by coupling of liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS), the ionization was performed by electrospray (ESI). After adjusting the experimental parameters, all additives were identified in the diesel fuel without sample preparation. The coupling of liquid chromatography at the critical condition chromatography (LCCC) with mass spectrometry was also evaluated in order to improve the separation of additives from the diesel fuel matrix. The characterization of polyalphaolefins (PAO) was carried out by IMS-MS with ASAP (atmospheric solids analysis probe) or APPI (atmospheric pressure photoionization) sources. With ASAP, in addition to pyrolysis ions, intact species were detected for low PAO grades. In the case of high PAO grades, only pyrolytic fragments were detected, yet it was possible to identify the alphaolefins used to produce the PAOs. In APPI, the use of halogenated solvents and toluene, allowed to observe intact species for high PAO grades through the formation of halogenated adducts. With IMS-MS coupling polyalphaolefins were differentiated the by the study of drift times and full width at half maximum.

Page generated in 0.0487 seconds