Projektering och energieffektivisering av värme- och ventilationssystem för ett flerbostadshus vid Vänern / Design and Energy Efficiency Calculations of the Heating and Ventilation System in a Building with Apartments Located at the lake Vänern in Sweden

Burrows, Michel January 2021 (has links)
En fastighet med ett antal lägenheter lokaliserad i den lilla tätorten Otterbäcken i Gullspångs kommun har brunnit ner. Fastigheten kommer att byggas upp på nytt igen. Det kommer att ske i enlighet med Boverkets byggregel BBR och de krav som är aktuella för 2021. Examensarbetet har varit ett samarbete mellan Högskolan i Borås och konsultföretaget Energitriangeln AB i Göteborg. Examensarbetet omfattar en ny projektering av fastigheten med avseende på val av teknisk lösning för uppvärmningssystemet och ventilationen. Som hjälp i projekteringen användes simuleringsprogrammet ”MagiCad från företaget Autodesk. De energitekniska beräkningarna av uppvärmningsbehovet genomfördes i simuleringsprogrammet BV2, ”Byggnadens Värmebalans i Varaktighetsdiagrammet” som tillhandahålls av företaget CIT, Chalmers Industriteknik. Den tekniska lösningen för lägenhetshuset omfattar en förbättring från den ursprungliga ventilationen som var ett självdragssystem till att bli antingen ett till- och frånluftssystem med värmeåtervinning, (FTX) eller ett frånluftssystem där värmeåtervinning i frånluften erhålls med hjälp av en frånluftvärmepump. Båda alternativen för en förbättrad ventilation projekterades med MagiCad programmet. Examensarbetet omfattar även en analys och beräkning av fastighetens energiprestanda med hjälp av simuleringsprogrammet BV2. Genom användningen av BV2 beräknades två fall och resultatet uttrycktes i specifik energiförbrukning av både el och värme i kWh/m2, år. Dels för fastigheten som projekteras med ett FTX- system för ventilationen och för projektering av en frånluftvärmepump för värmeåtervinning ur frånluften. För att kunna utföra detta projekt behövdes det bland annat tillgång till byggnadsritningar på den fastighet som håller på att byggas och projekteras oberoende av detta examensarbete. Syftet och huvudmålet med rapporten är att ge färdigheter och kunskap inom användningen och konfigurering av simuleringsprogrammet BV2 för energieffektivisering och på det viset kunna göra en jämförelse mellan två olika lösningar ur en ekonomisk synpunkt. Det är också viktigt att visa om de två tekniska lösningarna för ventilationen ger en energi-prestanda som överensstämmer med de krav som ingår Boverkets byggregler, BBR 28 från år 2019. Som en fortsättning av kursen CAD för VVS installationer ingick i examensarbetet en projektering av värme sekundär VS, tappvarmvatten, tappkallvatten och spillvatten med hjälp av MagiCad. Metodiken för energiprestandaberäkningarna i detta projekt var att mäta arean på skalet i fasaden, fönster och dörrar på byggnaden och använda som indata i simuleringsprogrammet av BV2. Resultatet av examensarbetet konstaterar att valet av en bergvärmepump är det bästa alternativet ur en ekonomisk synvinkel. Detta eftersom man behöver köpa färre antal kilowattimmar elektricitet för att kunna täcka värmebehovet i huset. Väljer man en bergvärmepump med ett FTX aggregat sparas i köpt värme för att kunna tillfredsställa fastighetens energibehov cirka 12 527 kWh/el som ger med ett rörligt elpris cirka 14 907 kr om året i besparing av köpt el för värmeproduktion i jämförelse med alternativet där en frånluftsvärmepump användes för värmeåtervinning från frånluften och där den kalla tilluften värms med en utökad area på radiatorsystemet. / A property with several apartments located in the small village of Otterbäcken in Gullspång municipality has burned down. The property will be rebuilt in accordance with Boverket buildings rules BBR and the requirements that are relevant for 2021.The diploma project has been a collaboration between the University of Borås and the consulting company Energi Triangeln AB located in the city of Gothenburg. As part of the project a re-design of the heating and ventilation system of the property will be carried out using two different simulation programs used when designing buildings. The first program is MagiCad from the company Autodesk. In this program drawings are made of the building including the drawings of the heating and ventilation systems. The second program is more focused at energy balances and energy efficiency calculation of the property. You get the energy performance of the property. The translated name is “Heat balances in a duration diagram”. The program is developed by a consulting company connected to Chalmers University of Technology named “Chalmers Industrial Technology”, CIT. The original technical solution for the ventilation in the building before it burned down was a system not using any fans. When rebuilding the house, the design of the ventilation system includes the comparison of two modern system both using extraction fans for forcing spent air to leave the building. The first alternative uses both a supply fan and exhaust fan with a heat exchanger for heat recovery of the heat in the exhaust ventilation duct. This system is used together with a heat pump taking heat from the ground. The second technical solution of ventilation system uses an exhaust fan in connection to a heat pump. That is a system where the heat recovery of the heat in the exhaust duct is recovered in the heat pump instead of extracting heat from the ground as in alternative one. Alternative two has no centralized intake of ventilation air, instead fresh air is coming into the apartments below windows in the sleeping rooms and living room of the apartments through individual ducts. By using the program energy performance program “BV2”, two different cases were calculated and expressed in specific energy consumption of both electricity and heat using the unit kWh/m2, per year. This means that the property which was designed with both an exhaust and a supply fan (and heat exchanger) for ventilation of the building and for the design with an exhaust air fan only but using a heat pump for heat recovery from the exhaust air, these two cases can be compared. To be able to carry out this project, it was necessary, among other things there was a need to access proper building drawings of the property that is being built and projected. The purpose and main objectives of the project are fulfilled. Furthermore, as a continuation of the course called “Computed Aided Design, (CAD), for buildings, the design of secondary heating, domestic hot and cold water and sewage water was carried out using MagiCad. The method used to carry out this project was to use the drawings of the building, measure the area of the shell, windows, doors, roofs and floor of the building and by using the second simulation program BV2 to be able to calculate the energy required of the building. The result of the degree project states that the choice of a geothermal heat pump with a heat exchanger for heat recovery between the exhaust duct and the duct with incoming fresh air provides the best alternative from an energy performance perspective. You consume fewer kilowatt hours to be able to cover the heating demand in the building. If you choose a geothermal heat pump with a heat recovery using only a heat exchanger the saving in purchased electricity to be able to satisfy the property´s energy demand is approximately 12 527 kWh/ electricity annually. which with a common electricity price in Sweden, (of 1.19 crowns/kWh) provides approximately 14 900 Swedish crowns per year in savings of purchased electricity for heat production.
12

Inneklimat i kontorsmiljö : Utvärdering av inneklimat i en kontorsmiljö med fokus på ventilationen / Indoor climate in office environment : Assessment of indoor climate in an office environment with focus on ventilation

Alhakim, Ali, Hakim, Roz January 2018 (has links)
I dagens samhälle tillbringar människan ca 90 procent av sin tid inomhus, vilket innebär att människan befinner sig i konstgjort inomhusklimat. Då människan tenderar att befinna sig inomhus är det stor vikt att ventilationen ska fungera så bra som möjligt och att inomhusklimatet är tillfredsställande för vårt välmående och välbefinnande på arbetsplatsen. Tidigare studier visar att nästan hälften av svenskar är missnöjda med ventilationen i deras arbetsmiljö (kontor). Ett bra inomhusklimat i kontorsmiljöer ökar tillfredställandet hos personalen, ökar produktiviteten samt minskar sjukfrånvaron. Detta leder till att organisationen/företaget besparar pengar i slutändan, då personalen arbetar mer effektivt och har mindre sjukfrånvaro. Syftet med denna studie är att undersöka klimatet i kontorsmiljön med fokus på termisk komfort samt se hur ventilation systemen påverkar inomhusklimatet. Vidare kommer sambanden mellan dessa att analyseras. Målet är undersöka hur komforten på kontoret påverkar människors hälsa, produktivitet och välmående. Målet är även att identifiera om det råder bristfällig ventilation samt att presentera eventuella förbättringar. I studien genomförs en undersökning av sex kontor på Brinellvägen 23. I undersökningen tillämpas en enkätstudie och ett antal olika mätningar, flödesmätningar, koldioxidsmätningar, temperaturmätningar och den relativa fuktigheten. I flödesmätningarna mäts till – och frånluften på samtliga kontor. Medan koldioxidmätningarna mäter även temperaturen och relativa fuktigheten. Koldioxidsmätningarna pågick i två timmar i 4 kontor, medan i de två resterande kontoren fortsatte mätningarna under en hel arbetsdag. Enkätstudien tilldelades ut till personalen i kontoren i syfte att ta del av subjektiva åsikter kring miljön i kontoren. Resultaten från mätningarna och enkätundersökningen visar att klimatet i kontoren i överlag inte var tillfredställande och obehag upplevdes utav personerna som arbetar där. Endast ett kontor uppfyllde det projekterade tilluftsflödet, medan de resterande kontoren varken uppfyllde projekterade flödena eller BBR:s krav för mängden flöde i kontorsmiljöer. Koldioxidhalten i kontoren med en person klarade av gränsen under 1000 ppm. Dock är kontoren projekterade för två personer och när två personer arbetade i kontoren översteg koldioxidhalten till ca 1200 ppm. Då koldioxidhalten överstiger 1000 ppm bör ventilationen kontrolleras, vilket behövs i detta fall. / In today's society, humans spend about 90 percent of their time indoors, in an artificial indoor climate. As people tend to be indoors more and more, it is important that the ventilation work as well and efficiently as possible, and that the indoor climate is pleasing for our well-being at the workplace. Previous studies show that almost half of Swedes are dissatisfied with the ventilation in their work environment (offices). A good indoor climate in offices increases employee satisfaction, increases productivity, and reduces absenteeism. This causes the organization / company to save money in the end, as staff work more efficiently and have less sick leave. The purpose of this study is to investigate the climate in office environment, focusing on thermal comfort and to see how ventilation systems affect the indoor climate. Furthermore, the relationships between these will be analyzed. The aim is to investigate how the comfort in the office affects human health, productivity and well-being. The goal is also to identify if there is insufficient ventilation to the offices that will be investigated and to eventually present possible improvements. In this report a study of six offices on Brinellvägen 23 was carried out. In the study, a number of flow measurements are carried out for each office's supply and exhaust air, carbon dioxide measurements, temperature and the relative humidity for four hours in four of the offices, with open and closed doors. While in two of the offices, the measurements continued for a whole working day, 6-8h. In addition to these measurements, surveys were distributed to the staff in the offices in order to share subjective opinions about the environment in the offices. The results from the measurements and the survey showed that the overall climate was not satisfactory, and discomfort was experienced by the people working there. Only one office met the projected supply airflow, while the remaining offices neither met the projected flows nor BBR requirements for the amount of flow in office environments. The carbon dioxide levels in the offices with one person was acceptable, they did not pass the limit of 1000 ppm. However, the offices were projected for two persons and when two persons worked in the offices, the carbon dioxide levels exceeded about 1200 ppm. When the carbon dioxide level exceeds 1000 ppm, it is recommended that the ventilation be checked, as needed in this case.
13

Självdrag eller FTX? : En jämförelse av ventilationssystem / Self-Exhaust Ventilation or Supply and Exhaust Ventilation ? : A Comparison of Ventilation Systems

Ali Mahmood, Chro, Yousefi, Leyla January 2023 (has links)
SammanfattningIntroduktion: Sedan år 2000 har antalet byggnader i Sverige ökat kraftigt. Enligt Statiska centralbyrån (SCB) fanns över 5 miljoner bostäder i Sverige i slutet av år 2021. Av dessa bostäder är cirka 42 % villor, 51 % flerbostadshus och resterande är lägenheter i specialbostäder. Energiförbrukningen i småhus har ökat med cirka 22% sedan 1970-talet, främst på grund av ökad användning av cirkulationspumpar, golvvärme och ventilation. Detta har resulterat i ökad miljöpåverkan från byggsektorn. Effektivisering av ventilationssystem har varit ett fokusområde under lång tid, eftersom användningsfasen av ventilationssystemen har visat sig ha hög energianvändning och stor miljöpåverkan. En studie visar att VVS-systemen påverkar miljön både vid tillverknings- och användningsfasen. Dessutom har nya lågenergihus en högre miljöpåverkan i byggfasen på grund av användningen av mer material för att minska driftanvändningen. Valet av ventilationssystem är avgörande för villor, eftersom ett effektivt ventilationssystem inte bara förbättrar inomhusluften utan också minskar risken för hälsoproblem som kan uppstå vid otillräcklig ventilation. Nyckelord: Livscykelkostnad, LCC, Ventilationssystem, Självdragssystem, FTX-system, VIP-Energy, Från- och tilluftssystem, Värmeåtervinning. Syfte: Syftet med examensarbetet är att visa att valet av ventilationssystem har betydelse för minskad klimatpåverkan vid tillverknings- och användningsfasen under 30 års tid. Mål: Målet är att ta fram vilket av självdragsventilation och från- och tilluftssystem med värmeåtervinning som är mest ekonomiskt och ger lägst klimatpåverkan baserat på ett livscykelperspektiv på ett småhus under en kalkylperiod på 30 år. Frågeställningar: Vilken av självdrag och FTX är mest effektivt med tanke på energiförbrukningen under tillverknings- och användningsfasen?Hur påverkar självdrag respektive FTX-systemet uppvärmningskostnaderna för ett småhus under förutsättning att uppvärmningen sker med fjärrvärme?Vilket av de två ventilationssystemen är mest ekonomisk lönsamt enligt en jämförande LCC, baserad på ett småhus med en kalkylperiod på 30 år?Vilket av ventilationssystemen orsakar störst klimatpåverkan? Metod: Metoden är en fallstudie där VIP-Energy används för att visa byggnadens energiförbrukning timme för timme under ett helt år. En LCC-beräkning utförs för att bestämma kostnaden för ventilationssystemet under dess livslängd, inklusive uppskattade underhållskostnader och nyinvesteringar. Slutsats: Baserat på energiförbrukningen under tillverknings- och användningsfasen är det mer effektivt att använda självdrag istället för ett FTX-system. Självdrag med vedeldning har ett lägre fjärrvärmebehov jämfört med FTX-systemet och ger därmed lägre årliga uppvärmningskostnader. Över en 30-årsperiod har självdragssystemet en lägre total livscykelkostnad än FTX-systemet. FTX-systemet har en högre elförbrukning och därmed en större påverkan på klimatet än självdragssystemet. / AbstractIntroduction: Since the year 2000, the number of buildings in Sweden has seen a significant increase. According to the Statistics Sweden (SCB), there were over 5 million dwellings in Sweden at the end of 2021. Out of these dwellings, approximately 42% are single-family houses, 51% are multi-family buildings, and the remaining is apartments in specialized housing. The energy consumption in single-family houses has increased by around 22% since the 1970’s, primarily due to the increased use of circulation pumps, underfloor heating, and ventilation. This has resulted in an increased environmental impact from the construction sector. Efficiency improvements in ventilation systems have been a longstanding focus due to the high energy consumption and significant environmental impact associated with their operational phase. A study reveals that HVAC systems impact the environment both during the manufacturing and the operational phases. Furthermore, new low-energy buildings have a higher environmental footprint during the construction phase due to the increased use of materials aimed at reducing operational energy consumption. The choice of a ventilation system is crucial for homes, as an efficient ventilation system not only improves indoor air quality but also reduces the risk of health problems that can arise from inadequate ventilation. Keywords: Life Cycle Cost, LCC, Ventilation System, Self-Exhaust Ventilation, Supply and Exhaust Ventilation, VIP-Energy, Supply and Exhaust Air System, Heat Recovery. Purpose: The purpose of the thesis is to demonstrate that the choice of ventilation system has a significant impact on reducing environmental emissions during the manufacturing and operational phases over a 30-year period. Goal: The objective is to determine which of self-exhaust ventilation and supply and exhaust ventilation with heat recovery is the most cost-effective and has the lowest climate impact based on a life-cycle perspective for a single-family building over a calculation period of 30 years.Questions: Which of self-exhaust ventilation and supply and exhaust ventilation is the most efficient in terms of energy consumption during the manufacturing and usage phases?How do self-exhaust ventilation and supply and exhaust ventilation affect the heating costs for a single-family building assuming that heating is provided through district heating?Which of the two ventilation systems is most economically viable according to a comparative Life Cycle Cost (LCC) analysis, based on a single-family building with a calculation period of 30 years?Which of the two ventilation systems causes the greatest climate impact?
14

A Study of Energy Saving Actions in Older Buildings in Sweden / En Studie om Energibesparing i Äldre Byggnader i Sverige

LEFFLER, OSCAR, MANSOUR, NASSIF January 2018 (has links)
Modern energy saving technologies are become increasingly mature, easier to implement and financially profitable. Both the European Union and the Swedish government have directives with goals regarding energy savings for the year 2020 and 2030. Here, making buildings more energy efficient plays a large role as around 40% of the total energy usage in Europe can be related to buildings. Constructing new, nearly zero energy houses is currently very popular, but as a vast majority of all buildings in a country like Sweden are older buildings, built before 1980, a majority of the used energy will come from these buildings. Hence, there is plenty of incentive for carrying out energy saving actions and investments in older buildings. From previous research and interviews with energy consultants, it can be concluded that energy saving actions are not being carried to the extent that is possible. This thesis aims to find out why this is and mainly what the main obstacles are when implementing energy saving solutions in older buildings. A case study, consisting of eight interviews with energy consultants and real estate owners was carried out in order to get an understanding of the current situation and the different stakeholders views on this issue. The results showed that, at least in the represented cases, there is a will among real estate owners for moving forward with energy saving. An understanding has also recently emerged where most real estate owners realize that there are great financial incentives connected to implementing energy saving solutions to current, older buildings. However, increased will of making a change has not yet resulted in a majority of buildings having installed energy saving solutions. One factor for this is that each building is its own individual case and therefore needs to be handled individually due to different conditions and are therefore suitable for different energy saving actions. Other factors include lack of technical and financial understanding among some real estate owners, slow decision making processes and ownership types. The research explores theories related to decision makings to provide a comprehensive overview regarding the current situation of energy saving in Sweden, as well as a contribution to the theoretical literature regarding decision making / Modern teknik inom energibesparing blir allt mer mognare, lättare att implementera och finansiellt lönsamt. Både den europeiska unionen och den svenska regeringen har direktiv med mål för energibesparing för år 2020 och 2030. Här spelar byggnader en viktig roll, då byggnader står för ca 40 % av den totala energianvändningen i Europa. Att bygga nya, nära noll energi byggnader är för närvarande väldigt populärt. Men i ett land som Sverige, där majoriteten av alla byggnader är äldre byggnader, kommer majoriteten av energianvändningen fortfarande från dessa. Därav finns det stora incitament till att genomföra energieffektiviserande åtgärder på äldre byggnader i Sverige. Från tidigare studier och intervjuer med energikonsulter kan det fastslås att energibesparande åtgärder ej genomförs i den grad som det är möjligt. Målet med denna rapport är att utröna varför det är så samt vilka huvudsakliga hinder som kan relateras till energibesparing i äldre byggnader. För att få en överblick av den befintliga situationen samt hur olika intressenter ser på denna fråga genomfördes en fallstudie bestående av åtta intervjuer med energikonsulter och fastighetsägare. Resultaten från studien pekade på att det finns en vilja bland fastighetsägare att gå vidare med energibesparande åtgärder. På senare tid har även en förståelse vuxit fram bland fastighetsägare där man inser att det även finns stora finansiella incitament med att implementera energibesparande åtgärder på äldre byggnader. Detta har dock ännu ej lett till att energibesparande åtgärder genomförts på en majoritet av befintliga byggnader. En anledning till detta är att varje byggnad måste hanteras individuellt då alla har olika förutsättningar och därmed lämpar sig för olika energibesparande lösningar. Andra faktorer inkluderar teknisk och ekonomisk kunskapsbrist bland vissa fastighetsägare, långsamma beslutsprocesser och ägarstrukturer. Studien nyttjar teorier relaterade till beslutsfattning för att ge läsaren en överblick av den befintliga situationen kring energibesparing i Sverige. I tillägg bidrar studien till den teoretiska litteraturen om beslutsfattning.