71 |
Estratégia de Significado para Economia Criativa: estudo de caso do PortomídiaANDRADE, Tarciana Araújo Brito de 20 October 2014 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-04-15T18:37:39Z
No. of bitstreams: 2
DISSERTAÇÃO Tarciana Araújo Brito de Andrade.pdf: 4701439 bytes, checksum: dbe5ebece2c8efb3e7fa63f8b5cb815d (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-15T18:37:39Z (GMT). No. of bitstreams: 2
DISSERTAÇÃO Tarciana Araújo Brito de Andrade.pdf: 4701439 bytes, checksum: dbe5ebece2c8efb3e7fa63f8b5cb815d (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2014-10-20 / A nova lógica econômica do mundo pede flexibilidade, se alimenta dos ativos culturais e criativos, buscando inclusive legitimar o uso da imaginação nas esferas pública, privada e na sociedade. Qualquer instituição, conglomerado de empresas ou cidade, tem potencial para investir em Economia Criativa. Para tanto, enxerga-se cada vez mais a necessidade de estimular a promoção de significados para prospectar novas atuações de mercado, já que as inovações tecnológicas parecem não ser mais suficientes como fonte de vantagem competitiva a longo prazo. Neste sentido, o propósito do Design Driven Innovation (DDI) tira o foco da quantidade de ideias e volta-se à quem pode contribuir para a criação de novos significados. O DDI pauta-se na criação de significados para produtos de uma empresa, enquanto que a Estratégia de Significado apresenta uma abordagem semântica para todos os componentes de um modelo de negócio institucional. Assim as redes colaborativas, o network e a identificação dos intérpretes tornam-se a fonte de criação de significados. No entanto, tem-se ciência que envolver diferentes stakeholders, dos diversos setores criativos, é uma tarefa árdua, não obstante estratégica, para uma economia emergente não estar tão dependente das commodities. Neste sentido, o presente estudo figura-se como um estudo de caso do Centro de Empreendedorismo e Tecnologias da Economia Criativa - o PORTOMÍDIA, uma recente iniciativa do Porto Digital, que almeja promover a Economia Criativa no Recife-PE. Esta pesquisa conta com o apoio do Ministério da Cultura do Brasil e do Núcleo de Gestão do Porto Digital - NGPD, e busca entender os objetivos, processos e perspectivas do Portomídia, sob a perspectiva do DDI e da estratégia de significado. A relevância da pesquisa encontra-se em sublinhar a promoção dos aspectos simbólicos para o modelo do negócio do Portomídia, como meio para criar valor à economia local. Ao final do estudo, apresentam-se diretrizes que possam vir a corroborar com o fomento de significados.
|
72 |
Transposição de dados da tomografia computadorizada para a superfície de triangulação e compassoCoutinho Dias Filho, Luiz January 2004 (has links)
Made available in DSpace on 2014-06-12T16:26:33Z (GMT). No. of bitstreams: 2
arquivo5516_1.pdf: 9164280 bytes, checksum: 525669ea5725efbecd3e6672c0c3724e (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2004 / Realizou-se uma análise criteriosa da eficácia do método da triangulação e compasso em
transferir dados da tomografia computadorizada para a superfície da cabeça. Para tal, alvos
radiopacos foram fixos nas cabeças de cadáveres humanos; em seguida, cada espécimen foi
submetido à tomografia computadorizada e intentou-se a localização dos alvos por meio de
triangulação e compasso. Os alvos foram distribuídos em diferentes regiões com o fito de
averiguar se a posição interferiria com a acurácia do método. Como referenciais utilizaramse
tanto marcos anatômicos como marcadores radiopacos. Dois grupos foram delineados,
um com e outro sem inclinação do gantry do tomógrafo. Quando a tomografia foi realizada
sem inclinação do gantry, constataram-se erros de 2,1±1,7mm e 1,7±1,2mm ao serem
utilizados, respectivamente, marcos anatômicos e marcadores radiopacos; a análise
estatística demonstrou não haver diferença significativa entre tais medidas. A localização
dos alvos tornou-se menos exata à medida que a inclinação do gantry foi aumentada. A
posição dos alvos não interferiu na acurácia do método. Os cálculos demandaram
7,1±1,0min. Os fatores de erro foram analisados e a aplicabilidade do método foi
defendida, alegando-se o bom proveito de seu uso no posicionamento de craniotomias, na
efetivação de biópsias e na punção de cistos, hematomas e abscessos. Com respeito à
transferência de dados da tomografia computadorizada para a superfície da cabeça foi
demonstrado que o método da triangulação e compasso é tão eficaz quanto a
neuronavegação e um pouco menos que a estereotaxia convencional. Quando comparado a
outros métodos, foram nítidas as vantagens relativas à acurácia e exeqüibilidade. Ademais,
devem ser ressaltados o baixo custo do procedimento e o mínimo desconforto para o
paciente
|
73 |
Efeito do cemento dental na regeneração periodontal : um estudo histomorfometrico em cãesGonçalves, Patricia Furtado 02 October 2006 (has links)
Orientadores: Francisco Humberto Nociti Junior, Marcio Zaffalon Casati / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T21:22:40Z (GMT). No. of bitstreams: 1
Goncalves_PatriciaFurtado_D.pdf: 1584484 bytes, checksum: 320d77faa174f7b65746904c2c6166c6 (MD5)
Previous issue date: 2006 / Resumo: Tendo sido demonstrada a possibilidade de preservação do cemento como forma alternativa de tratamento da doença periodontal, o presente estudo teve como objetivo avaliar o efeito do cemento dental na regeneração periodontal. Foram utilizados nove cães, sem raça definida, que receberam ligaduras de fio de algodão nos terceiros pré-molares inferiores, bilateralmente, para produzir lesões de bifurcação classe III. Após o levantamento de retalhos mucoperiosteais, os defeitos foram aleatoriamente escolhidos para receber um dos seguintes tratamentos: (A) remoção do tecido de granulação e uma cuidadosa raspagem e alisamento radicular, utilizando curetas e brocas, objetivando a remoção dos depósitos duros e moles e do cemento radicular, e polimento radicular com taças de borracha e pasta profilática; (B) somente a remoção do tecido de granulação e polimento radicular com taças de borracha e pasta profilática, objetivando a preservação do cemento radicular. Em ambos os grupos, os defeitos foram tratados com o princípio da Regeneração Tecidual Guiada (membranas reabsorvíveis - RESOLUT XT®) e os retalhos foram posicionados coronariamente e suturados. Após quatro meses os animais foram sacrificados para uma análise histomorfométrica. No grupo B, houve uma maior extensão (3,59±1,67 e 6,20±2,26mm para os grupos A e B, respectivamente; p=0,004) e espessura (18,89±9,47 e 52,29±22,48µm para os grupos A e B, respectivamente; p=0,001) de novo cemento, uma maior extensão de novo osso (1,86±1,76 e 4,62±3,01mm para os grupos A e B, respectivamente; p=0,002), além de uma maior extensão de regeneração periodontal, quando comparado ao grupo A (p<0,05 ¿ Wilcoxon). Observou-se ainda, no grupo B, uma menor formação de tecido epitelial/conjuntivo sobre a superfície radicular (2,77±0,79 e 1,10±1,48mm para os grupos A e B, respectivamente; p=0,009), além de uma maior porcentagem de preenchimento da área do defeito (80,95±17,46 e 94,50±10,27 para os grupos A e B, respectivamente; p<0,05), com uma maior proporção de novo osso e uma menor proporção de tecido epitelial/conjuntivo (p<0,05). Dentro dos limites deste estudo, conclui-se que o cemento dental pode modular a regeneração periodontal / Abstract: The aim of the present study was to histometrically evaluate, in dogs, the effect of root cementum on periodontal regeneration. Nine mongrel dogs were used to obtain bilateral chronic class III furcation defects by placing cotton ligatures around both third mandibular premolars. The teeth were randomly assigned to receive one of the following treatments: (A) Scaling and root planning, by means of hand and rotatory instruments, in order to remove soft and hard deposits as well as all root cementum; (B) Removal of only soft microbial deposits, by polishing the root surface with rubber cups and polishing paste, aiming at maximum root cementum preservation. Both groups were treated with Guided Tissue Regeneration (GTR), with the use of resorbable poliglycolic-lactic-acid membranes (RESOLUT XT®) covering the buccal e lingual aspects of the furcation defect, and the flaps coronally positioned. Four months after the treatment, the animals were sacrificed and the histological sections obtained. Data analysis showed that a superior length (3.59±1.67 vs. 6.20±2.26mm; p=0.004) and a thicker layer (18.89±9.47 vs. 52.29 ±22.48µm; p=0.001) of new cementum were observed for group B (p<0.05). Additionally, group B presented and a superior length of new bone (1.86±1.76 vs. 4.62±3.01mm; p= 0.002) and less soft tissue along the root surface (2.77±0.79 vs. 1.10±1.48mm; p=0.009), and a larger proportion of periodontal regeneration when compared to control (p<0.05). A larger area of new bone (p=0.018) and a smaller area of soft tissue (p=0.024) were also observed for group B (p<0.05 - Wilcoxon). Within the limits of this study, it can be concluded that root cementum may modulate periodontal regeneration / Doutorado / Periodontia / Doutor em Clínica Odontológica
|
74 |
Efecto del plasma rico en plaquetas en la regeneración ósea postexodoncia del tercer molar impactadoQuincho Rosales, Dilmer Armando January 2017 (has links)
Determina el efecto en la regeneración ósea postexodoncia del tercer molar impactado. El estudio se realiza con 20 pacientes con necesidad de exodoncia del tercer molar inferior bilateral. Las exodoncias se efectúan en un mismo tiempo quirúrgico y en uno de ellos, escogido aleatoriamente, se aplica el gel de PRP y el otro tomado como grupo control. La evaluación posoperatoria se lleva acabo hasta pasado los tres meses y medio, los parámetros evaluados son: dolor posoperatorio y curación de herida (efecto clínico), efecto radiográfico y efecto tomográfico. / Tesis
|
75 |
Estudio Prospectivo Comparativo de la Eficacia en el Aumento Horizontal de Crestas Alveolares Atróficas con Regeneración Ósea Guiada y Expansores Motorizados de CrestaNart Molina, José 20 January 2010 (has links)
The purpose of this prospective, randomized, controlled clinical investigation is to evaluate the performance of the Motorized Ridge Expanders (MRE), and to compare its results with the ones achieved utilizing lateral ridge augmentation (LRA). Eight subjects with bilateral ridge deformities were selected. One technique was used on the right site and the other on the left site. Implants were placed six months after the bone augmentation procedures. All the measurements were recorded at 2 and 5 mm from the most coronal part of the crest. The augmentation achieved with both techniques was statistically significant, 1.2 mm in the LRA, 1.5 mm in MRE at 2 mm from the crest; 1.5 mm and 1.6 mm respectively at 5mm from the crest. The differences between the two techniques were statistically insignificant. The amount of expansion achieved in the MRE site appears to be negatively correlated (P-Value <0.05) with the thickness of the cancellous bone, and it is not affected by the thickness of the cortical plate. The MRE technique appears to be as effective as the LRA technique in augmenting the thickness of atrophic ridges. The defect treated with the MRE showed less bone width contraction during the first 6 months of healing. Histologically, the regenerated bone was vital, trabecular in nature and in direct contact with bone graft particles. / El propósito de esta investigación clínica prospectiva y aleatoria es comparar el aumento horizontal de la cresta alveolar obtenido con el uso de los expansores motorizados de cresta (EMC) y con regeneración ósea guiada (ROG). Fueron selecccionados ocho pacientes con deformidades horizontales del reborde alveolar bilaterales que iban a recibir implantes dentales. Una técnica de regeneración se utilizó en el lado derecho y la otra en el lado izquierdo, para un total de 23 muestras, 13 en el lado experimental (EMC) y 10 en el lado control (ROG). Los implantes fueron colocados seis meses después de los procedimientos de aumento óseo, y se obtuvo una muestra de hueso para estudio histológico. Todas las mediciones clínicas se registraron a los 2 y 5 mm de la parte más coronal de la cresta. El aumento logrado con ambas técnicas fue estadísticamente significativo, de 1,2 mm en la ROG y 1,5 mm con los EMC a 2 mm de la cresta; y 1,5 mm y 1,6 mm, respectivamente, a 5mm de la cresta. Las diferencias entre las dos técnicas no fueron estadísticamente significativas. La cantidad de expansión lograda en el sitio de los EMC parece tener una correlación negativa (p <0,05) con el grosor del hueso esponjoso, y no se ve afectada por el grosor de la cortical. Histológicamente se observó osteoconductividad del injerto óseo y más partículas residuales del mismo en el lado experimental. La técnica de los EMC parece ser tan eficaz como la técnica de ROG en el aumento de la anchura de las crestas atróficas. Los defectos tratados con los EMC mostraron una menor contracción del injerto óseo durante los 6 meses de cicatrización. / El propòsit d'aquesta recerca clínica prospectiva i aleatòria és comparar l'augment horitzontal de la cresta alveolar obtingut amb l'ús dels expansors motoritzats de cresta (EMC) i amb regeneració òssiaguiada (ROG). Es van selecccionar vuit pacients amb deformitats horitzontals bilaterals de la cresta alveolar on es col.locaren implants dentals. Una tècnica de regeneració es va emprar en el costat dret i l'altra a la banda esquerra, per a un total de 23 mostres, 13 al costat experimental (EMC) i 10 en el costat control (ROG). Els implants van ser col.locats sis mesos després dels procediments d'augment ossi, i es va obtenir una mostra d'os per estudi histològic.Totes les mesures clíniques es van registrar als 2 i 5 mm de la part més coronal de la cresta. L'augment aconseguit amb ambdues tècniques va ser estadísticament significatiu, de 1,2 mm a la ROG i 1,5 mm amb els EMC a 2 mm de la carena, i 1,5 mm i 1,6 mm, respectivament, a 5mm de la cresta. Les diferències entre les duestècniques no van ser estadísticament significatives. La quantitat d'expansió aconseguida en el lloc dels EMC sembla tenir una correlació negativa (p<0,05) amb el gruix de l'os esponjós, i no es veu afectada per el gruix de la cortical. Histològicament es observar osteoconductividad l'empelt ossi i més partícules residuals d'aquest en el costat experimental. La tècnica dels EMC sembla ser tan eficaç com la tècnica de ROG en l'augment de l'amplada de les crestes atròfiques. Els defectes tractats amb els EMC mostrar una menor contracció de l'empelt ossi durant els 6 mesos de cicatrització.
|
76 |
Desvios lineares e angulares de implantes com guias prototipadas fixadas em modelos experimentais / Linear and angular deviations of implants placed with fixed stereolithographic drill guides in experimental modelsNovellino, Marcelo Michele 11 August 2011 (has links)
Considerando as dificuldades que ocorrem com a localização e o posicionamento de implantes e, ainda, o risco de deslocamento das guias, tomográfica e cirúrgica, durante os procedimentos de diagnóstico e cirúrgico, foi objetivo desta pesquisa avaliar, se a alternativa de introduzir dispositivos para retenção e suporte, nas guias da técnica de cirurgia guiada convencional, interfere na posição e inclinação de implantes no momento da sua colocação. Foram confeccionados 10 modelos simulando tecido ósseo, divididos aleatoriamente em 2 grupos: 5 com a guia tomográfica e cirúrgica da técnica convencional, denominado grupo controle (M); 5 com as guias fixadas a ortoimplantes modificados associados ao sistema de encaixe o ring, representando o grupo experimental (MI). A avaliação dos resultados foi pela sobreposição dos planejamentos virtuais (Implant Viewer), derivados de tomografias computadorizadas pré-cirúrgicas, com as realizadas após a colocação dos implantes. Os resultados obtidos mostraram que não houve diferenças estatisticamente significantes para os desvios angulares (Teste Tukey F= 1,06 e p= 0, 3124) e lineares (Teste ANOVA F = 2,54 e p = 0,11). No entanto, os valores angulares individuais do grupo experimental (MI), mostraram ser mais próximos entre si, com menor variabilidade, quando comparados ao grupo controle. Concluiuse, que o uso de ortoimplantes associados ao sistema de encaixe o ring, pode trazer benefícios à técnica da cirurgia guiada convencional, reduzindo as alterações de posicionamento dos implantes no momento da sua colocação. / Computer guided surgery is an excellent alternative to the proper insertion of implants in patients with an edentulous arch or a partially edentulous area and with appropriate quantity of bone. Considering the difficulties that occur with implants placement and the risk of displacement of radiographic and surgical template during the diagnostic and surgical procedures, the aim of this research was to assess if an alternative devices for retention of radiographic and surgical templates can bring benefits for a more accurate implant placement. Ten models made by a material that simulates bone tissue were randomly divided into 2 groups: 5 with the conventional radiographic and surgical guide, which was called control group (M); 5 with modified orthodontic implants that fixed the radiographic and the surgical templates, representing the experimental group (MI). The evaluation of the results was by matching virtual plans (Implant Viewer), derived from pre-operative cone-beam CT images, with post-operative ones to calculate the deviation between planned and installed implants. The results showed that there was no statistically significant differences for angular (Tukey F = 1.06 and p = 0, 3124) and linear deviations (test ANOVA F = 2.54 and p = 0.11). However, the individual angular values of experimental group (MI) showed to be closer to each other, with lower variability when compared to control group. It was concluded that the use of modified orthodontic implant with o ring attachment can bring benefits to conventional guided surgery technique, reducing changes in ideal implant position.
|
77 |
Avaliação do uso de substituto ósseo sintético associado a membrana de colágeno absorvível na preservação da crista óssea alveolar após extração dentária. Estudo clínico e tomográfico em humanos / Evaluation of synthetic bone substitute use associated with absorbable collage membrane in preserving the alveolar crest after tooth extraction. Clinical and tomographic study in humansSantos, Felipe Anderson Sousa dos 30 January 2015 (has links)
Objetivo: o objetivo deste ensaio clínico controlado aleatorizado foi avaliar o uso de um substituto ósseo sintético associado a uma membrana de colágeno absorvível na preservação da crista óssea alveolar após extração dentária, por meio de análises clínica e tomográfica em humanos. Metodologia: Quatorze pacientes foram selecionados, cada um apresentando ao menos dois dentes anteriores maxilares indicados para extração: no Grupo Teste (GT), o alvéolo pós-exodontia foi preenchido pelo substituto ósseo sintético Reprobone, e no Grupo Controle (GC) houve o preenchimento do alvéolo apenas por coágulo. Em ambos os grupos os alvéolos foram cobertos por uma membrana absorvível de colágeno (BioMend), que por sua vez foi recoberta por um retalho mucoperióstico fechado oclusivamente. Tomografias computadorizadas do tipo Cone Beam foram realizadas no pós-operatório imediato e após 6 meses do procedimento cirúrgico, e as alterações dimensionais horizontais e verticais das cristas ósseas foram quantificadas. Para a análise estatística intragrupo utilizou-se o teste t pareado; para avaliações intergupo, teste t não pareado. Em todas as comparações foi adotado um nível de significância de 5%. Resultados: A Medida Vertical Vestibular reabsorveu 1,5 mm (ou 21,3%) da medida inicial no Grupo Teste (p<0,05) e 1,8 mm (ou 25,8%) no Grupo Controle (p<0,05). A Medida Vertical Palatina diminuiu 0,3 mm em ambos os grupos (p>0,05). A Altura Máxima reduziu 0,5 mm ou 7,9% no grupo com Reprobone e BioMend quando comparada ao baseline (p>0.05), e 1,1 mm ou 14,8% no grupo com BioMend apenas (p<0,05), sendo esta diferença intergrupo estatisticamente significante (p<0,05). A Medida Horizontal Apical diminuiu 0,2 mm no GT, o equivalente a 2,9% (p>0,05), enquanto que no GC diminuiu 0,5 mm ou 7,3% (p<0,05), não havendo diferença estatisticamente significante entre os grupos. A Medida Horizontal Cervical (MHC) perdeu 0,5 mm ou 7,2% no GT e 1,4 mm ou 15,1 % no GC: a análise intragrupo apontou diferença estatística entre os dados iniciais e após 6 meses para este parâmetro (p<0,05), em ambos os grupos, e também foi encontrada diferença estatisticamente significante na avaliação entre grupos para a MHC. Conclusão: Os resultados obtidos demonstraram que o uso do Reprobone associado à Biomend apresentou benefícios e melhores resultados na manutenção vertical e horizontal do rebordo alveolar em comparação ao uso apenas da membrana colágena. / Objective: The aim of this randomized controlled clinical trial was to evaluate the use of a synthetic bone substitute associated with an absorbable collagen membrane in preserving the alveolar crest after tooth extraction, through clinical and tomography analysis in humans. Methods: Fourteen patients were selected, each featuring at least two front teeth jaws indicated for extraction: in Test Group (TG), the post-extraction sockets were filled by the synthetic bone substitute ReproBone, and the control group (CG) was filling the alveoli only by clot. In both groups, the wells were covered with a resorbable collagen membrane (BioMend), which in turn was covered with a mucoperiosteal flap closed occlusally. CT Cone Beam type were performed in the immediate postoperative period and after 6 months of surgery, and the horizontal and vertical dimensional changes of the bone crests were quantified. For intra-group statistical analysis used the paired t test; to intergupo reviews, unpaired t test. In all comparisons was adopted a 5% significance level. Results: Vestibular Vertical Measure reabsorbed 1.5 mm (or 21.3%) of the original measure in the test group (p <0.05) and 1.8 mm (or 25.8%) in the control group (p <0 , 05). The Measured Vertical Palatine 0.3 mm decreased in both groups (p> 0.05). The Maximum Height reduced 0.5 mm or 7.9% for the ReproBone and BioMend compared to baseline (p> 0.05), and 1.1 mm or 14.8% for the BioMend only (p <0.05 ), statistically significant intergroup difference (p <0.05). Measure the horizontal apical decreased by 0.2 mm WG, equivalent to 2.9% (p> 0.05), whereas the CG 0.5 mm or decreased by 7.3% (p <0.05), not statistically significant difference between groups. The Horizontal Cervical Measure (MHC) lost 0.5 mm or 7.2% in GT and 1.4 mm or 15.1% of CG: the intra-group analysis showed statistical difference between the initial data and after 6 months for this parameter (p <0.05) in both groups, and was also a statistically significant difference between groups in the evaluation for the MHC. Conclusion: The results showed that the use of ReproBone associated with BioMend presented benefits and better results in vertical and horizontal maintenance of alveolar ridge compared to using only the collagen membrane.
|
78 |
Avaliação do uso de substituto ósseo sintético associado a membrana de colágeno absorvível na preservação da crista óssea alveolar após extração dentária. Estudo clínico e tomográfico em humanos / Evaluation of synthetic bone substitute use associated with absorbable collage membrane in preserving the alveolar crest after tooth extraction. Clinical and tomographic study in humansFelipe Anderson Sousa dos Santos 30 January 2015 (has links)
Objetivo: o objetivo deste ensaio clínico controlado aleatorizado foi avaliar o uso de um substituto ósseo sintético associado a uma membrana de colágeno absorvível na preservação da crista óssea alveolar após extração dentária, por meio de análises clínica e tomográfica em humanos. Metodologia: Quatorze pacientes foram selecionados, cada um apresentando ao menos dois dentes anteriores maxilares indicados para extração: no Grupo Teste (GT), o alvéolo pós-exodontia foi preenchido pelo substituto ósseo sintético Reprobone, e no Grupo Controle (GC) houve o preenchimento do alvéolo apenas por coágulo. Em ambos os grupos os alvéolos foram cobertos por uma membrana absorvível de colágeno (BioMend), que por sua vez foi recoberta por um retalho mucoperióstico fechado oclusivamente. Tomografias computadorizadas do tipo Cone Beam foram realizadas no pós-operatório imediato e após 6 meses do procedimento cirúrgico, e as alterações dimensionais horizontais e verticais das cristas ósseas foram quantificadas. Para a análise estatística intragrupo utilizou-se o teste t pareado; para avaliações intergupo, teste t não pareado. Em todas as comparações foi adotado um nível de significância de 5%. Resultados: A Medida Vertical Vestibular reabsorveu 1,5 mm (ou 21,3%) da medida inicial no Grupo Teste (p<0,05) e 1,8 mm (ou 25,8%) no Grupo Controle (p<0,05). A Medida Vertical Palatina diminuiu 0,3 mm em ambos os grupos (p>0,05). A Altura Máxima reduziu 0,5 mm ou 7,9% no grupo com Reprobone e BioMend quando comparada ao baseline (p>0.05), e 1,1 mm ou 14,8% no grupo com BioMend apenas (p<0,05), sendo esta diferença intergrupo estatisticamente significante (p<0,05). A Medida Horizontal Apical diminuiu 0,2 mm no GT, o equivalente a 2,9% (p>0,05), enquanto que no GC diminuiu 0,5 mm ou 7,3% (p<0,05), não havendo diferença estatisticamente significante entre os grupos. A Medida Horizontal Cervical (MHC) perdeu 0,5 mm ou 7,2% no GT e 1,4 mm ou 15,1 % no GC: a análise intragrupo apontou diferença estatística entre os dados iniciais e após 6 meses para este parâmetro (p<0,05), em ambos os grupos, e também foi encontrada diferença estatisticamente significante na avaliação entre grupos para a MHC. Conclusão: Os resultados obtidos demonstraram que o uso do Reprobone associado à Biomend apresentou benefícios e melhores resultados na manutenção vertical e horizontal do rebordo alveolar em comparação ao uso apenas da membrana colágena. / Objective: The aim of this randomized controlled clinical trial was to evaluate the use of a synthetic bone substitute associated with an absorbable collagen membrane in preserving the alveolar crest after tooth extraction, through clinical and tomography analysis in humans. Methods: Fourteen patients were selected, each featuring at least two front teeth jaws indicated for extraction: in Test Group (TG), the post-extraction sockets were filled by the synthetic bone substitute ReproBone, and the control group (CG) was filling the alveoli only by clot. In both groups, the wells were covered with a resorbable collagen membrane (BioMend), which in turn was covered with a mucoperiosteal flap closed occlusally. CT Cone Beam type were performed in the immediate postoperative period and after 6 months of surgery, and the horizontal and vertical dimensional changes of the bone crests were quantified. For intra-group statistical analysis used the paired t test; to intergupo reviews, unpaired t test. In all comparisons was adopted a 5% significance level. Results: Vestibular Vertical Measure reabsorbed 1.5 mm (or 21.3%) of the original measure in the test group (p <0.05) and 1.8 mm (or 25.8%) in the control group (p <0 , 05). The Measured Vertical Palatine 0.3 mm decreased in both groups (p> 0.05). The Maximum Height reduced 0.5 mm or 7.9% for the ReproBone and BioMend compared to baseline (p> 0.05), and 1.1 mm or 14.8% for the BioMend only (p <0.05 ), statistically significant intergroup difference (p <0.05). Measure the horizontal apical decreased by 0.2 mm WG, equivalent to 2.9% (p> 0.05), whereas the CG 0.5 mm or decreased by 7.3% (p <0.05), not statistically significant difference between groups. The Horizontal Cervical Measure (MHC) lost 0.5 mm or 7.2% in GT and 1.4 mm or 15.1% of CG: the intra-group analysis showed statistical difference between the initial data and after 6 months for this parameter (p <0.05) in both groups, and was also a statistically significant difference between groups in the evaluation for the MHC. Conclusion: The results showed that the use of ReproBone associated with BioMend presented benefits and better results in vertical and horizontal maintenance of alveolar ridge compared to using only the collagen membrane.
|
79 |
Aplica??o da hidroxipropilmetilcelulose na s?ntese de biomateriais para regenera??o e engenharia de tecidos e an?lise de sua toxicidade em cultura de c?lulas adiposo-derivadas humanasFavalli, Paulo Pereira de Souza 14 October 2009 (has links)
Made available in DSpace on 2015-04-14T13:34:47Z (GMT). No. of bitstreams: 1
418546.pdf: 3263858 bytes, checksum: 98405799e09a5518c35fdb38c15ba169 (MD5)
Previous issue date: 2009-10-14 / A regenera??o e engenharia de tecidos passam pela aplica??o de c?lulas precursoras multipotentes associadas a biomateriais, os quais devem oferecer a elas um ambiente tridimensional an?logo ? matriz extracelular existente nos organismos vivos. Aprimorar um hidrogel de hidroxipropilmetilcelulose (HPMC), agregando a ele duas fun??es caracter?sticas de scaffolds, isto ?, ser mold?vel ou favor?vel ? ades?o celular tridimensional, para o uso em regenera??o e engenharia de tecidos foi a inten??o do presente estudo. O desenvolvimento de uma propriedade mold?vel foi obtido baseado em experi?ncias da literatura que citam a s?ntese de HPMC com silano (HPMC-Si). Esta s?ntese permitiu que o hidrogel assumisse o aspecto de gelatina, atrav?s de autorreticula??o em fun??o do pH, mold?vel de acordo com o defeito a ser corrigido. Paralelamente, seguindo outra tend?ncia no desenvolvimento de scaffolds compostos por hidrog?is, sintetizou-se HPMC com pept?deos R-G-D-S (arginina- glicina- ?cido asp?rtico- serina), atrav?s de rea??o por esterifica??o. Isto conferiu ao hidrogel s?tios de ades?o, visando a sua intera??o com c?lulas dentro de um contexto tridimensional. A partir das s?nteses, avaliou-se a viabilidade de c?lulas aderentes adiposoderivadas humanas (CAADh), cultivadas em 2D na presen?a dos hidrog?is HPMC pura, HPMC-Si e HPMC-RGDS, para se determinar a citotoxicidade dos mesmos (ensaio MTT de acordo com a ISO 10993-5), comparando-os entre si e com grupos-controle negativo (CN) e positivo (CP), em 24, 48 e 72h. Os tr?s hidrog?is presentes nas culturas n?o interferiram na viabilidade das c?lulas (% de atividade MTT), durante os 3 momentos observados, quando comparados com o grupo CP (P< 0,001). Ao mesmo tempo, as c?lulas cultivadas em contato com os g?is demonstraram viabilidade semelhante ao grupo CN. Entretanto, ainda que sejam at?xicos em contato com culturas de c?lulas em monocamada, testes de citotoxicidade em 3D devem confirmar a efetividade dos hidrog?is aprimorados HPMC-Si e HPMC-RGDS como scaffolds aplic?veis em regenera??o e engenharia de tecidos.
|
80 |
Modelo experimental em ratos no reparo ?sseo do f?mur utilizando c?lulas mononucleares no plasma rico em plaquetasKopschina, M?rcia Illana 25 February 2010 (has links)
Made available in DSpace on 2015-04-14T13:34:51Z (GMT). No. of bitstreams: 1
422340.pdf: 14563536 bytes, checksum: b6883cbe3401270733359041afa6d671 (MD5)
Previous issue date: 2010-02-25 / INTRODU??O: As c?lulas mononucleares (CMs) da medula ?ssea t?m sido utilizadas em diversas patologias na tentativa de regenera??o tecidual. O objetivo deste estudo foi avaliar a ades?o de c?lulas mononucleares sobre um defeito cr?tico, com a adi??o do plasma rico em plaquetas (PRP) e/ou TGF-β1 (Fator de crescimento transformador Beta 1) e, por fim, verificar o reparo ?sseo dos s?tios defeituosos dos f?mures dos ratos. M?TODOS: Foi criado um defeito cr?tico bilateral nos f?mures de 33 ratos Wistar-Kyoto. C?lulas mononucleares da medula ?ssea, TGF-β e PRP foram adicionadas no lado tratado da les?o e soro fisiol?gico no lado contralateral. Avaliou-se a ades?o de c?lulas mononucleares sobre o defeito cr?tico e o reparo ?sseo. RESULTADOS: A presen?a e conseq?ente ades?o das c?lulas mononucleares administradas nos animais tratados n?o foram evidenciadas atrav?s de t?cnica de PCR. As an?lises radiogr?ficas evidenciam fechamento da les?o nos grupos CMs +TGF-β e CMs + PRP, por?m, n?o podemos afirmar se foi pelos tratamentos administrados ou pela pr?pria regenera??o ?ssea, quando analisadas em 6 e 10 semanas, haja visto n?o apresentarem diferen?as significativas entre os grupos. CONCLUS?ES: a) as c?lulas mononucleares da medula ?ssea n?o aderiram ao defeito cr?tico criado no f?mur do rato; b) N?o foi poss?vel avaliar a efici?ncia relativa dos tratamentos propostos no reparo ?sseo, uma vez que n?o houve diferen?as significativas na avalia??o dos grupos.
|
Page generated in 0.038 seconds