• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 69
  • 53
  • 8
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 282
  • 113
  • 106
  • 81
  • 59
  • 54
  • 45
  • 43
  • 37
  • 36
  • 36
  • 35
  • 33
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

建立衡量跨組織系統績效之量化架構 / BUILD THE QUANTITATIVE FRAMEWORK TO MEASURE THE PERFORMANCE OF INTER-ORGANIZATIONAL SYSTEMS

曾菁美, Tseng,Ching Mei Unknown Date (has links)
跨組織系統(IOS)是一種由兩間或多間企業所共同使用的自動化資訊系統。有越來越多的企業利用跨組織系統來推動企業間的合作互動,因此,如何衡量跨組織系統所產出的績效便是相當重要的課題。本研究主要是提供一個量化的方式來衡量跨組織系統,不單只著重衡量企業內部,同時也將外部的供應商部份納入考量。最後,本研究以一間台灣的PC製造商作為分析個案,針對此個案做事後分析,印證本研究所提出的量化架構。 / IOS (Inter-Organizational Systems) is defined as automated information systems shared by two or more companies. While more and more enterprises use IOS to promote the collaboration between companies, what kinds of values are derived from IOS and how to evaluate these IOS become important to enterprises. This research aims to provide a quantitative approach to measure IOS values, not only considering the benefits within internal enterprise, but also paying attention to those from external processes with suppliers. We try to propose a new evaluated model. In order to justify our framework, we take one Taiwanese PC manufacturer as a case and do the post-hoc analysis. Through the case study, we prove that our model is validated. We propose new four perspectives in our IOS quantitative framework: IT infrastructure perspective, internal business process perspective, business supplier perspective and business performance. Afterwards, we try to determine the processes in each perspective according to perspectives and then find the quantitative indicators to support our measurement. Lastly, we can even calculate the return on investment (ROI) and break-even point that make enterprises can know the IOS operation more clearly. Therefore, the contribution of this research can be two-folded: first, enterprises can build an IOS quantitative framework to evaluate both intra-firm and inter-firm IOS values quantitatively. Second, enterprises can exactly know how the IOS work, inclusive of detailed processes and interactions with suppliers and how many investment and rewards that enterprises really get.
182

En jämförande studie i prestanda mellan React Native och Ionic

Stenqvist, Oscar, Claesson, Tommy January 2019 (has links)
Purpose – To examine if there is any difference regarding performance between the two frameworks Ionic and React Native to ease decisions which one to use when developing mobile applications. Method – A comparative study with hypothesis based on earlier studies are tested with different experiments. Findings – Ionic is performing faster in the majority of the experiments, but at the same time its CPU and memory usage is higher. The results also show that React Native is struggling with larger data-sets. Implications – The study is contributing to a wider knowledge about cross-platform frameworks performance, and therefore facilitates the choice on which framework is more preferable to use. Limitations – The study only includes Ionic and React Native, and no conclusions can therefore be applied to any other cross-platform frameworks. The results are not generalizable to cross- platform native vs cross-platform hybrid, or Android vs IOS / Syfte – Studiens syfte var att undersöka om det är någon skillnad prestandamässigt mellan ramverken Ionic och React Native för att utveckla ett beslutsunderlag och underlätta val av ramverk vid utveckling av applikationer. Metod – En jämförande studie som införskaffat en teoretisk bakgrund genom en litteraturstudie, och sedan framställt hypoteser som testats genom olika experiment. Resultat – Studiens resultat visade att Ionic presterade snabbare än React Native i majoriteten av experimenten, samtidigt som CPU och minnesanvändningen var högre. Resultaten beror antagligen på hur ramverken använder sig av olika tekniker som bland annat DOM och virtuell DOM för att rendera saker på skärmen. Resultaten visar också att React Native har stora problem att rendera större datamängder då applikationen låser sig fram till dess att den lyckats rendera allt. Implikationer – Studien bidrar till att bredda kunskapsbasen och underlätta vid val mellan olika ramverk för utveckling av cross-platform applikationer. Begränsningar – Studien avhandlar bara React Native och Ionic som ramverk, inga slutsatser kan dras för skillnader mellan cross-platform native och cross-platform hybrid. Applikationerna är byggda utan tidigare erfarenhet utav ramverken.
183

Sonographie der Lunge und Analyse der Atmungsmechanik mittels Impuls-Oszilloresistometrie beim lungengesunden und pneumoniekranken Ferkel und Läuferschwein

Klein, Carmen 28 November 2004 (has links) (PDF)
Carmen Klein: Sonographie der Lunge und Analyse der Atmungsmechanik mittels Impuls-Oszilloresistometrie beim lungengesunden und pneumoniekranken Ferkel und Läuferschwein Institut für Bakteriologie und Mykologie der Veterinärmedizinischen Fakultät der Universität Leipzig Bundesinstitut für gesundheitlichen Verbraucherschutz und Veterinärmedizin (BgVV), Fachbereich 4 in Jena eingereicht im Mai 1999, verteidigt am 16. November 1999 (157 Seiten, 52 Abbildungen, 34 Tabellen, 285 Literaturstellen; Anhang mit: 62 Seiten, 15 Abbildungen und 50 Tabellen) Mit der Sonographie der Lunge und der Impuls-Oszilloresistometrie (IOS - engl.: Impulse Oscilloresistometry System) wurden erstmals zwei nichtinvasive diagnostische Verfahren auf ihre Anwendbarkeit und Aussagefähigkeit bei lungengesunden und pneumoniekranken Absatzferkeln und Läuferschweinen bis zu einer Körpermasse von ca. 50 kg geprüft. Die sonographische Untersuchung der Lunge wurde an insgesamt 45 lungengesunden bzw. pneumoniekranken Schweinen durchgeführt. Dazu wurden die Tiere mit 2,0 mg/kg KM Diazepam sediert. Eine Studie an sechs klinisch gesunden Schweinen gab Aufschluß über die Ausdehnung des bei dieser Tierart sonographisch erreichbaren Lungenfeldes. Die bei Pneumonien häufig betroffenen kranioventral gelegenen Lungenabschnitte waren sonographisch gut zu erreichen. Die bei der sonographischen Untersuchung der Lunge des Schweines nachgewiesenen Befunde zeigten eine gute Übereinstimmung mit den in der Literatur an anderen Spezies beschriebenen Resultaten. Beim Schwein wurden folgende Befundbilder abgegrenzt: ? keine Veränderungen : sonographisch o.b.B. ? geringgradige Veränderungen: Kometenschweifartefakte in geringer Ausprägung ? mittelgradige Veränderungen: Kometenschweifartefakte und Konsolidierungen oder echogenes Grundmuster mit Kometenschweifartefakten ? hochgradige Veränderungen: echogenes Grundmuster oder echogenes Grundmuster mit Abszeß oder Nekrose Die Befunde der sonographischen Untersuchung der Lunge wurden bei 34 Schweinen den entsprechenden pathologisch-anatomischen Befunden zugeordnet. Pathologisch-anatomisch unverändertes Gewebe stellte sich mit einer Wahrscheinlichkeit (Sensitivität) von 95,65 % ohne bzw. mit nur geringradigen sonographischen Veränderungen dar. Bei pathologisch-anatomisch verändertem Gewebe wurden mit einer Wahrscheinlichkeit von 74,62 % (Sensitivität) mittel- und hochgradig veränderte sonographische Befundbilder festgestellt. In die histologische Untersuchung wurden insgesamt 49 Gewebeproben einbezogen. Rückschlüsse vom sonographischen Befund auf die Art der histologisch diagnostizierten Pneumonie waren beim Schwein nicht möglich. Es wurde jedoch eine statistisch gesicherte Beziehung zwischen dem Ausprägungsgrad der histologischen Veränderung und den sonographischen Befunden festgestellt. Der Ausprägungsgrad der histologischen Veränderung stand u.a. in direkter Beziehung zum Luftgehalt im Lungengewebe. Die Impuls-Oszilloresistometrie ist ein Verfahren zur Analyse der Atmungsmechanik und wurde am Schwein ebenfalls unter Sedation mit Diazepam (1,5 bis 2,0 mg/kg KM) oder aber nach entsprechendem Training der Tiere ohne jede medikamentelle Ruhigstellung vorgenommen. Die Schweine wurden in einer Hängematte streßarm fixiert und das Meßsystem über eine starre, luftdicht am Kopf abschließende Atemmaske an das Tier adaptiert. Insgesamt 26 Schweine wurden in die Studien zur Untersuchung verschiedener Einflüsse auf das Verhalten der IOS-Parameter einbezogen. Folgende Parameter wurden berücksichtigt: Atmungsfrequenz (Af), Atemzugvolumen (Vt), die Spektralparameter Resistance (R), Reactance (X) und Kohärenz (K) jeweils bei 5, 10, 15 und 20 Hz (R5, ...R20, X5, ...X20, K5, ...K20) sowie die Modellparameter zentrale (Rz) und periphere (Rp) Resistance, Lungencompliance (Cl) und zentrale Inertance (Lz). In einer Variabilitätsanalyse an fünf nicht sedierten, klinisch gesunden Schweinen wurde die Reproduzierbarkeit der Ergebnisse bei drei unmittelbar innerhalb weniger Minuten aufeinander folgend sowie bei an drei Tagen nacheinander zur selben Tageszeit durchgeführten IOS-Messungen überprüft. Innerhalb des kurzen Zeitraumes von wenigen Minuten wurde die Variabilität der Meßergebnisse der meisten IOS-Parameter überwiegend durch inter-individuelle Einflüsse verursacht, während bei der über mehrere Tage reichenden Betrachtungsweise der intra-individuell bedingte Anteil der Variabilität zunahm. Die Entwicklung von Alter und Körpermasse konnten im Rahmen der an elf klinisch gesunden, sedierten Schweinen über einen Zeitraum von 62 Tagen vorgenommenen IOS-Messungen nur teilweise die mit dem Wachstum einhergehenden Veränderungen der IOS-Parameter erklären. Der an acht klinisch gesunden, sedierten Schweinen festgestellte Einfluß der Tageszeit auf die IOS-Parameter war nur gering, stimmte aber von der Tendenz her mit den in der Literatur beschriebenen Angaben überein. An 16 klinisch gesunden Schweinen wurde der Einfluß der Sedation mit Diazepam auf die IOS-Parameter überprüft. Dieses Medikament führte zu einer signifikanten Verringerung von Af und Vt und zu einer Verbesserung der Qualität der IOS-Messungen (K5, K10, K20). An sieben klinisch gesunden, nicht sedierten Schweinen wurden durch Inhalation von Aerosolen mit bestimmten pharmakologisch wirksamen Substanzen (Carbachol, Fenoterolhydrobromid) definierte Zustände am respiratorischen System wie Bronchospasmus und Bronchodilatation ausgelöst und mittels IOS-Messungen nachgewiesen. Die während der bronchospastischen Reaktion vorgefundenen Veränderungen der IOS-Parameter, insbesondere der starke Anstieg der Resistance im unteren Frequenzbereich (R5), das deutliche Absinken der Reactance, insbesondere bei 5 Hz, und die beträchtliche Erhöhung des Modellparameters Rp sind für diesen Zustand des Bronchialsystems charakteristisch. Neun klinisch gesunde, sedierte Schweine wurden zunächst bei physiologischer und anschließend bei stark distal abgebeugter Kopfhaltung untersucht. Durch die starke Flexion im Kopf-Hals-Bereich wurde eine extrathorakal gelegene Obstruktion erzeugt. Hierbei waren die spektrale Resistance (R5 bis R20) und der Modellparameter Rz bei abgebeugter Kopfhaltung signifikant erhöht. Am Beispiel einer experimentell ausgelösten Infektion mit Actinobacillus pleuropneumoniae wurde der Verlauf einer respiratorischen Erkrankung an sieben sedierten Schweinen unter regelmäßiger Durchführung von IOS-Messungen, über einen Zeitraum von 23 Tagen verteilt, beobachtet. Die Resultate der IOS-Messungen 3 Tage p.i. (Resistance im gesamten Frequenzbereich erhöht, starker Anstieg von Rz und Lz ) wiederspiegelten vor allem eine Beteiligung der extrathorakal und zentral gelegenen Bereiche des Respirationstraktes. Durch die zumindest tendenziell vorhandenen Veränderungen bestimmter IOS-Parameter (Verstärkung der negativen Frequenzabhängigkeit, Erhöhung von Rp, Abnahme von Cl) wurde zusätzlich eine Beteiligung der peripheren Bereiche in der Lunge angezeigt. Für einen definierten Zeitraum wurden die IOS-Meßergebnisse den Befunden der sonographischen Untersuchung der Lunge gegenübergestellt. Dabei wurden hohe Korrelationen zwischen auf periphere Veränderungen verweisenden IOS-Parametern und sonographisch ermittelten Veränderungen an der Lunge nachgewiesen. Abschließend ist festzustellen: 1.) Beide getesteten diagnostischen Verfahren sind beim Schwein anwendbar und liefern eine wertvolle Ergänzung der konventionellen Diagnostik am Respirationstrakt dieser Tierart. 2.) Nach sonographischer Untersuchung der Lunge sind mit hoher Wahrscheinlichkeit Aussagen über das Vorhandensein pathologisch-anatomisch sichtbarer pneumonischer Verän-derungen und deren Ausdehnung im sonographisch erreichbaren Lungenfeld möglich. 3.) Die Impuls-Oszilloresistometrie liefert in einem Parameter-Komplex Informationen über den funktionellen Zustand des gesamten respiratorischen Systems. Dieser ist von zahlreichen physiologisch wirkenden Faktoren (u.a. Kopfhaltung, Wachstum, Tageszeit), applizierten pharma-kologisch wirksamen Substanzen (z.B. Diazepam, Carbachol, Fenoterolhydrobromid) und dem Vorhandensein einer Erkrankung des respiratorischen Systems (z.B. Actinobacillus pleuropneumoniae) abhängig. 4.) Da beide Verfahren verschiedene Sachverhalte, den morphologischen (Sonographie) bzw. den funktionellen Zustand (Impuls-Oszilloresistometrie) des respiratorischen Systems widerspiegeln, liefern sie einander ergänzende Aussagen. 5.) Beide diagnostischen Verfahren bieten sich beim Schwein vor allen Dingen für den Einsatz zu wissenschaftlichen Zwecken an. Aufgrund ihres nichtinvasiven Charakters ist ein schonender Umgang mit den Probanden möglich. 6.) Die Anwendung der Sonographie der Lunge ist auch in ausgewählten Fällen der tierärztlichen Praxis, z.B. beim Ankauf von Zuchttieren, denkbar. / Carmen Klein: Lung Sonography and Analysis of the Respiratory Mechanics by means of Impulse Oscilloresistometry in Healthy and Pneumonic Piglets and Porkers Institute of Bacteriology and Mycology Faculty of Veterinary Medicine University of Leipzig Germany Federal Institute for Health Protection of Consumers and Veterinary Medicine Jena Branch Germany submitted in May 1999 (157 pages, 52 figures, 34 tables, 285 references, appendix with 62 pages, 15 figures, 50 tables) Two non-invasive diagnostic methods, i.e. lung sonography and impulse oscillometry, were examined for the first time with regard to their applicability and evidence in clinically healthy as well as pneumonic weaned piglets and porkers of up to ca. 50 kg b.w. A total of 45 healthy or pneumonic swine was subjected to lung sonography. For this purpose, the animals were sedated with 2.0 mg/k b.w. diazepam. Six clinically healthy swine were studied to establish the lung area accessible to sonography in this animal species. Sonography was found to cover well the cranioventral sections of the lung often affected by pneumonias. The findings established by lung sonography in the swine showed a good coincidence with results described in literature for other species. The findings in swine revealed the following picture. ? No changes: sonography NAD ? Low-grade changes: little pronounced comet-tail artefacts ? Moderate changes: Comet-tail artefacts and consolidations or echogenic basic pattern including comet-tail artifacts ? High-degree changes: basic echogenic pattern or basic echogenic pattern plus abscess or necrosis Lung sonography findings in 34 swine were assigned to the corresponding pathological-anatomical findings. Tissue considered as unchanged from the pathological-anatomical angle was found to be without or with only minor sonographic changes, with a probability (sensitivity) of 95.65 %. In tissue exhibiting pathological-anatomical changes, sonographic findings showed pictures of moderate and high-degree changes, with a probability (sensitivity) of 74.62 % A total of 49 tissue samples was subjected to histological examination. It was not possible to infer, from the sonographic findings, the type of pneumonia diagnosed histologically in the swine. Nevertheless, a statistically confirmed correlation between the degree of pronouncedness of the histological changes and the sonographic findings was established. The pronouncedness of the histological changes was, like other factors, directly related to the air content of the lung tissue. Impulse oscillometry being a method used to analyze respiratory mechanics was applied to swine either sedated by means of diazepam (1.5 - 2.0 mg/kg b.w.) or non-sedated by medication but trained correspondingly. The animals were fixed in a canvas sling with openings for the limbs, avoiding stress, and the measuring system was adapted to the animal using a rigid face mask hermetically fitting to the animal's head. A total of 26 animals was included in the studies to examine a variety of factors influencing the IOS parameters. The following parameters were considered: Respiratory rate (Af), tidal volume (Vt), the spectral parameters resistance (R), reactance (X) and coherence (K) at 5, 10, 15 and 20 Hz each (R5, ...R20, X5, ...X20, K5, ...K20) as well as the model parameters, central (Rz) and peripheral (Rp) resistance, lung compliance (Cl) and central inertance (Lz). A variability analysis involving five non-sedated, clinically healthy swine served to examine the reproducibility of the results of three IOS measurements either performed consecutively within a few minutes, or on three consecutive days at the same time of the day. During the brief period of a few minutes, the variability of the results of measurements, for most parameters, was due to inter-individual factors while in the case of an analysis over several days, the intra-individual share of variability increased. In the context of the IOS measurements performed in eleven clinically healthy, sedated swine over a period of 62 days, development in terms of age and body weight could only partially explain the variations of the IOS parameters taking place with growth. The influence of the time of the day on IOS parameters studied in eight clinically healthy, sedated swine was found to be small; coincidence with data given in literature, however, was seen as a tendency. The influence of diazepam sedation on the IOS parameters was examined in 16 clinically healthy swine. This medication resulted in a significant reduction of Af and Vt and improved quality of IOS measurements (K5, K10, K20). In seven clinically healthy, non-sedated swine, defined respiratory situations, i.e. bronchospasm and bronchodilatation were generated by aerosol inhalation of pharmacologically active substances such as carbachol and fenoterolhydrobromide and demonstrated by IOS measurements. This state of the bronchial system is characterized by the changes in IOS parameters found at the time of the bronchospasmic reaction, in particular the vehement rise of resistance in the lower frequency range (R5), the obvious drop in reactance, especially at 5 Hz and the noteworthy rise in the model parameter, Rp. Nine clinically healthy, sedated swine were examined first with their heads in a physiological and then, in a vertical position of their heads. The severe bending in the head-neck area produced an extrathoracic obstruction. Spectral resistance (R5 - R20) and the model parameter, Rz were significantly higher at a vertical position of the head. An experimental infection of seven sedated swine with Actinobacillus pleuropneumoniae served as a model to study the course of respiratory disease. The animals were subjected to regular IOS measurements over a period of 23 days. The results of IOS measurements performed 3 days p.i. (elevated resistance over the entire frequency range, vehement rise of Rz and Lz) reflected, above all, an involvement of the extrathoracic and central areas of the respiratory tract. As a result, the modifications of defined IOS parameters (intensification of negative frequency dependency, rise in Rp, drop in Cl) which were present at least as a tendency, indicated an additional involvement of the peripheral lung areas. The results of IOS measurements over a defined period were compared with the findings from lung sonography. High correlations between IOS parameters indicating peripheral changes and lung changes detected by sonography were demonstrated. Conclusions 1.) Both diagnostic methods studied may be used in swine and will provide a valuable completion of conventional diagnosis in the respiratory tract of this species. 2.) With a high probability, lung sonography will provide evidence of the presence of visible pathological-anatomical changes in the lung and their extent in the lung area that is accessible to sonography. 3.) Impulse oscillometry provides a complex of parameters that contain information about the functional state of the entire respiratory system. This state is dependent upon numerous physiological factors (among them position of the head, growth, time of the day), pharmacologically active substances administered (e.g. diazepam, carbachol, fenoterolhydrobromide) and the presence of respiratory disease (e.g. caused by Actinobacillus pleuropneumoniae). 4.) Since the two methods reflect different facts, i.e. the morphological (sonography) and the functional (impulse oscillometry) state of the respiratory system, they supply mutually supplementing information. 5.) Both diagnostic methods offer themselves above all for use in scientific research on swine. Owing to their non-invasive character, it is possible to handle test animals in a non-offensive way. 6.) In specific cases, lung sonography may also be used in the veterinary practitioner's surgery, e.g. for the examination of animals kept for breeding.
184

Digitalisierung der Engineering Prozesse durch System Lifecycle Management (SysLM)

Eigner, Martin 03 September 2021 (has links)
Dieser Beitrag erläutert die Umsetzung der Digitalisierung speziell im Anwendungsgebiet des Engineering. Dabei wird die Digitalisierung, sowohl des eigentlichen Produktes als auch der im Rahmen von Service-orientierten Geschäftsmodellen entwickelten Dienstleistung, vorgestellt. Ein weiterer wesentlicher Punkt der Digitalisierung sind die horizontale und vertikale Integration der technischen und administrativen Arbeitsprozesse entlang des Produktlebenszyklus. Bei den vertikalen Integrationen handelt es ich um die Integrationen der Autorensysteme entlang den Lebenszyklusphasen Anforderungsmanagement, Systemarchitektur, CAD in Mechanik, Elektronik, Softwareentwicklung, Simulation, Test, Prozessplanung und Digitale Fabrik. Bei der horizontalen Integration stehen die administrativen Funktionen wie Freigabe-, Änderungs- und Konfigurationsmanagement über den gesamten Produklebenszyklus und die technische Integration der in den einzelnen Produktlebenszyklus-Phasen erzeugten Informationen im Vordergrund. Hier ist vor allem die Verteilung und Orchestrierung der Funktionen zwischen SysLM, MES und PPS relevant.
185

Adoptionsfaktorer vid implementering av molnbaserad redovisning : En kvalitativ studie på små och medelstora redovisningsbyråer / Factors to cloud-based client accounting adoption : A qualitative study on small and medium accounting practices

Jonsson, Jennifer, Schou, Anton January 2022 (has links)
Syfte: Molnbaserade tjänster har blivit allt vanligare i redovisningsbranschen. Därför syftar denna studie till att undersöka vilka faktorer som ligger till grund för små och medelstora redovisningsbyråers adoptionsbeslut vid implementeringen av molnbaserad klientredovisning. Metod: Studien utgår ifrån den hermeneutiska forskningsfilosofin med en abduktiv ansats då tidigare studier inom området varit få och att vi söker förståelse för motiven bakom människors handlingar. Rent praktiskt har elva semi-strukturerade intervjuer hos små och medelstora redovisningsbyråer genomförts. En modifierad EDI-adoptionsmodell har använts som en del av studiens teoretiska utgångspunkt. Resultat och slutsats: Faktorer som påverkar beslutet följer till stor del den modifierade EDI- adoptionsmodellen. Däremot hade organisatorisk beredskap inte lika stor påverkan som övriga tre kategorier. Dessutom upptäcktes en ny faktor, trygghet. Examensarbetets bidrag: Studien bidrar till en förståelse för vilka faktorer som är av betydelse vid adoption av molnbaserade redovisningssystem. Det bör vara av intresse för leverantörer, men även ge stöd åt redovisningsbyråer som står inför ett sådant beslut. Förslag till fortsatt forskning: Ett förslag är att undersöka vilka faktorer som är av betydelse i framtiden när molnbaserad redovisning är mindre nytt, hur byråer påverkas efter implementeringen samt hur relationerna med klienterna och lönsamheten påverkas. Vidare hade det varit önskvärt att undersöka den nytillkomna faktorn, trygghet, och se om den bör läggas till som en del av en ny modifierad EDI-adoptionsmodell. / Aim: Cloud computing is more interesting now than ever before, especially in the accounting industry. Therefore, this study aims to examine which factors motivate small and medium sized accounting practices to adopt cloud-based client accounting. Method: This study assumes a hermeneutic research philosophy with an abductive approach because of the lack of previous studies in the field and that we are seeking to understand motives behind people's actions. Eleven semi-structured interviews were conducted with employees from small and medium-sized accounting practices. A modified EDI-adoption model was used as a part of the study's theoretical framework. Results and conclusions: The results show that most of the factors follow the modified EDI- adoption model but the organisational readiness didn ́t have as much impact on SMP:s decision as the others. A new factor, safety, was also discovered. Contribution of the thesis: The study contributes to an understanding of which factors that have an impact on SMP:s decision to adopt cloud-based client accounting. The findings should be of interest to different cloud accounting providers such as Fortnox, as well as accounting practices that are thinking about adopting cloud-based client accounting. Suggestions for future research: One suggestion for future research is to study which factors have an impact on SMP:s in the future when cloud-based accounting isn ́t seen as something new and how the client relationships and profitability of the practices will be affected by the adoption. Also, it would be interesting to examine the new factor, safety, and see if it should be a part of the future EDI-adoption model.
186

Hedonické nebo pragmatické preference? Komparativní analýza uživatelů platforem Android a iOS z pohledu UX a informačního chování / Hedonic or pragmatic preferences? A comparative analysis of Android and iOS users from the perspective of UX and information behaviour

Scholleová, Klára January 2021 (has links)
The theoretical part of the thesis presents the evolution of the fields of human-computer interaction (HCI) and user experience (UX) including hedonic-pragmatic model of user experience. It further presents platforms and ecosystems in general, the evolution of smartphone market and the platforms of Android and iOS, and explains the basic concepts of information and consumer behaviour. A part of the thesis is a qualitative study examining the differences between the preferences towards smartphones of Android and iOS users, and differences in their information behaviour. It was found out that the participants - users of both platforms have mostly pragmatic reasons for their platform preference but describe them differently; that Android users seek more information at the time of smartphone purchase decision and that some iOS users, unlike Android users, started using their platform based on observation of others' good user experience with it.
187

Sonographie der Lunge und Analyse der Atmungsmechanik mittels Impuls-Oszilloresistometrie beim lungengesunden und pneumoniekranken Ferkel und Läuferschwein

Klein, Carmen 19 April 2000 (has links)
Carmen Klein: Sonographie der Lunge und Analyse der Atmungsmechanik mittels Impuls-Oszilloresistometrie beim lungengesunden und pneumoniekranken Ferkel und Läuferschwein Institut für Bakteriologie und Mykologie der Veterinärmedizinischen Fakultät der Universität Leipzig Bundesinstitut für gesundheitlichen Verbraucherschutz und Veterinärmedizin (BgVV), Fachbereich 4 in Jena eingereicht im Mai 1999, verteidigt am 16. November 1999 (157 Seiten, 52 Abbildungen, 34 Tabellen, 285 Literaturstellen; Anhang mit: 62 Seiten, 15 Abbildungen und 50 Tabellen) Mit der Sonographie der Lunge und der Impuls-Oszilloresistometrie (IOS - engl.: Impulse Oscilloresistometry System) wurden erstmals zwei nichtinvasive diagnostische Verfahren auf ihre Anwendbarkeit und Aussagefähigkeit bei lungengesunden und pneumoniekranken Absatzferkeln und Läuferschweinen bis zu einer Körpermasse von ca. 50 kg geprüft. Die sonographische Untersuchung der Lunge wurde an insgesamt 45 lungengesunden bzw. pneumoniekranken Schweinen durchgeführt. Dazu wurden die Tiere mit 2,0 mg/kg KM Diazepam sediert. Eine Studie an sechs klinisch gesunden Schweinen gab Aufschluß über die Ausdehnung des bei dieser Tierart sonographisch erreichbaren Lungenfeldes. Die bei Pneumonien häufig betroffenen kranioventral gelegenen Lungenabschnitte waren sonographisch gut zu erreichen. Die bei der sonographischen Untersuchung der Lunge des Schweines nachgewiesenen Befunde zeigten eine gute Übereinstimmung mit den in der Literatur an anderen Spezies beschriebenen Resultaten. Beim Schwein wurden folgende Befundbilder abgegrenzt: ? keine Veränderungen : sonographisch o.b.B. ? geringgradige Veränderungen: Kometenschweifartefakte in geringer Ausprägung ? mittelgradige Veränderungen: Kometenschweifartefakte und Konsolidierungen oder echogenes Grundmuster mit Kometenschweifartefakten ? hochgradige Veränderungen: echogenes Grundmuster oder echogenes Grundmuster mit Abszeß oder Nekrose Die Befunde der sonographischen Untersuchung der Lunge wurden bei 34 Schweinen den entsprechenden pathologisch-anatomischen Befunden zugeordnet. Pathologisch-anatomisch unverändertes Gewebe stellte sich mit einer Wahrscheinlichkeit (Sensitivität) von 95,65 % ohne bzw. mit nur geringradigen sonographischen Veränderungen dar. Bei pathologisch-anatomisch verändertem Gewebe wurden mit einer Wahrscheinlichkeit von 74,62 % (Sensitivität) mittel- und hochgradig veränderte sonographische Befundbilder festgestellt. In die histologische Untersuchung wurden insgesamt 49 Gewebeproben einbezogen. Rückschlüsse vom sonographischen Befund auf die Art der histologisch diagnostizierten Pneumonie waren beim Schwein nicht möglich. Es wurde jedoch eine statistisch gesicherte Beziehung zwischen dem Ausprägungsgrad der histologischen Veränderung und den sonographischen Befunden festgestellt. Der Ausprägungsgrad der histologischen Veränderung stand u.a. in direkter Beziehung zum Luftgehalt im Lungengewebe. Die Impuls-Oszilloresistometrie ist ein Verfahren zur Analyse der Atmungsmechanik und wurde am Schwein ebenfalls unter Sedation mit Diazepam (1,5 bis 2,0 mg/kg KM) oder aber nach entsprechendem Training der Tiere ohne jede medikamentelle Ruhigstellung vorgenommen. Die Schweine wurden in einer Hängematte streßarm fixiert und das Meßsystem über eine starre, luftdicht am Kopf abschließende Atemmaske an das Tier adaptiert. Insgesamt 26 Schweine wurden in die Studien zur Untersuchung verschiedener Einflüsse auf das Verhalten der IOS-Parameter einbezogen. Folgende Parameter wurden berücksichtigt: Atmungsfrequenz (Af), Atemzugvolumen (Vt), die Spektralparameter Resistance (R), Reactance (X) und Kohärenz (K) jeweils bei 5, 10, 15 und 20 Hz (R5, ...R20, X5, ...X20, K5, ...K20) sowie die Modellparameter zentrale (Rz) und periphere (Rp) Resistance, Lungencompliance (Cl) und zentrale Inertance (Lz). In einer Variabilitätsanalyse an fünf nicht sedierten, klinisch gesunden Schweinen wurde die Reproduzierbarkeit der Ergebnisse bei drei unmittelbar innerhalb weniger Minuten aufeinander folgend sowie bei an drei Tagen nacheinander zur selben Tageszeit durchgeführten IOS-Messungen überprüft. Innerhalb des kurzen Zeitraumes von wenigen Minuten wurde die Variabilität der Meßergebnisse der meisten IOS-Parameter überwiegend durch inter-individuelle Einflüsse verursacht, während bei der über mehrere Tage reichenden Betrachtungsweise der intra-individuell bedingte Anteil der Variabilität zunahm. Die Entwicklung von Alter und Körpermasse konnten im Rahmen der an elf klinisch gesunden, sedierten Schweinen über einen Zeitraum von 62 Tagen vorgenommenen IOS-Messungen nur teilweise die mit dem Wachstum einhergehenden Veränderungen der IOS-Parameter erklären. Der an acht klinisch gesunden, sedierten Schweinen festgestellte Einfluß der Tageszeit auf die IOS-Parameter war nur gering, stimmte aber von der Tendenz her mit den in der Literatur beschriebenen Angaben überein. An 16 klinisch gesunden Schweinen wurde der Einfluß der Sedation mit Diazepam auf die IOS-Parameter überprüft. Dieses Medikament führte zu einer signifikanten Verringerung von Af und Vt und zu einer Verbesserung der Qualität der IOS-Messungen (K5, K10, K20). An sieben klinisch gesunden, nicht sedierten Schweinen wurden durch Inhalation von Aerosolen mit bestimmten pharmakologisch wirksamen Substanzen (Carbachol, Fenoterolhydrobromid) definierte Zustände am respiratorischen System wie Bronchospasmus und Bronchodilatation ausgelöst und mittels IOS-Messungen nachgewiesen. Die während der bronchospastischen Reaktion vorgefundenen Veränderungen der IOS-Parameter, insbesondere der starke Anstieg der Resistance im unteren Frequenzbereich (R5), das deutliche Absinken der Reactance, insbesondere bei 5 Hz, und die beträchtliche Erhöhung des Modellparameters Rp sind für diesen Zustand des Bronchialsystems charakteristisch. Neun klinisch gesunde, sedierte Schweine wurden zunächst bei physiologischer und anschließend bei stark distal abgebeugter Kopfhaltung untersucht. Durch die starke Flexion im Kopf-Hals-Bereich wurde eine extrathorakal gelegene Obstruktion erzeugt. Hierbei waren die spektrale Resistance (R5 bis R20) und der Modellparameter Rz bei abgebeugter Kopfhaltung signifikant erhöht. Am Beispiel einer experimentell ausgelösten Infektion mit Actinobacillus pleuropneumoniae wurde der Verlauf einer respiratorischen Erkrankung an sieben sedierten Schweinen unter regelmäßiger Durchführung von IOS-Messungen, über einen Zeitraum von 23 Tagen verteilt, beobachtet. Die Resultate der IOS-Messungen 3 Tage p.i. (Resistance im gesamten Frequenzbereich erhöht, starker Anstieg von Rz und Lz ) wiederspiegelten vor allem eine Beteiligung der extrathorakal und zentral gelegenen Bereiche des Respirationstraktes. Durch die zumindest tendenziell vorhandenen Veränderungen bestimmter IOS-Parameter (Verstärkung der negativen Frequenzabhängigkeit, Erhöhung von Rp, Abnahme von Cl) wurde zusätzlich eine Beteiligung der peripheren Bereiche in der Lunge angezeigt. Für einen definierten Zeitraum wurden die IOS-Meßergebnisse den Befunden der sonographischen Untersuchung der Lunge gegenübergestellt. Dabei wurden hohe Korrelationen zwischen auf periphere Veränderungen verweisenden IOS-Parametern und sonographisch ermittelten Veränderungen an der Lunge nachgewiesen. Abschließend ist festzustellen: 1.) Beide getesteten diagnostischen Verfahren sind beim Schwein anwendbar und liefern eine wertvolle Ergänzung der konventionellen Diagnostik am Respirationstrakt dieser Tierart. 2.) Nach sonographischer Untersuchung der Lunge sind mit hoher Wahrscheinlichkeit Aussagen über das Vorhandensein pathologisch-anatomisch sichtbarer pneumonischer Verän-derungen und deren Ausdehnung im sonographisch erreichbaren Lungenfeld möglich. 3.) Die Impuls-Oszilloresistometrie liefert in einem Parameter-Komplex Informationen über den funktionellen Zustand des gesamten respiratorischen Systems. Dieser ist von zahlreichen physiologisch wirkenden Faktoren (u.a. Kopfhaltung, Wachstum, Tageszeit), applizierten pharma-kologisch wirksamen Substanzen (z.B. Diazepam, Carbachol, Fenoterolhydrobromid) und dem Vorhandensein einer Erkrankung des respiratorischen Systems (z.B. Actinobacillus pleuropneumoniae) abhängig. 4.) Da beide Verfahren verschiedene Sachverhalte, den morphologischen (Sonographie) bzw. den funktionellen Zustand (Impuls-Oszilloresistometrie) des respiratorischen Systems widerspiegeln, liefern sie einander ergänzende Aussagen. 5.) Beide diagnostischen Verfahren bieten sich beim Schwein vor allen Dingen für den Einsatz zu wissenschaftlichen Zwecken an. Aufgrund ihres nichtinvasiven Charakters ist ein schonender Umgang mit den Probanden möglich. 6.) Die Anwendung der Sonographie der Lunge ist auch in ausgewählten Fällen der tierärztlichen Praxis, z.B. beim Ankauf von Zuchttieren, denkbar. / Carmen Klein: Lung Sonography and Analysis of the Respiratory Mechanics by means of Impulse Oscilloresistometry in Healthy and Pneumonic Piglets and Porkers Institute of Bacteriology and Mycology Faculty of Veterinary Medicine University of Leipzig Germany Federal Institute for Health Protection of Consumers and Veterinary Medicine Jena Branch Germany submitted in May 1999 (157 pages, 52 figures, 34 tables, 285 references, appendix with 62 pages, 15 figures, 50 tables) Two non-invasive diagnostic methods, i.e. lung sonography and impulse oscillometry, were examined for the first time with regard to their applicability and evidence in clinically healthy as well as pneumonic weaned piglets and porkers of up to ca. 50 kg b.w. A total of 45 healthy or pneumonic swine was subjected to lung sonography. For this purpose, the animals were sedated with 2.0 mg/k b.w. diazepam. Six clinically healthy swine were studied to establish the lung area accessible to sonography in this animal species. Sonography was found to cover well the cranioventral sections of the lung often affected by pneumonias. The findings established by lung sonography in the swine showed a good coincidence with results described in literature for other species. The findings in swine revealed the following picture. ? No changes: sonography NAD ? Low-grade changes: little pronounced comet-tail artefacts ? Moderate changes: Comet-tail artefacts and consolidations or echogenic basic pattern including comet-tail artifacts ? High-degree changes: basic echogenic pattern or basic echogenic pattern plus abscess or necrosis Lung sonography findings in 34 swine were assigned to the corresponding pathological-anatomical findings. Tissue considered as unchanged from the pathological-anatomical angle was found to be without or with only minor sonographic changes, with a probability (sensitivity) of 95.65 %. In tissue exhibiting pathological-anatomical changes, sonographic findings showed pictures of moderate and high-degree changes, with a probability (sensitivity) of 74.62 % A total of 49 tissue samples was subjected to histological examination. It was not possible to infer, from the sonographic findings, the type of pneumonia diagnosed histologically in the swine. Nevertheless, a statistically confirmed correlation between the degree of pronouncedness of the histological changes and the sonographic findings was established. The pronouncedness of the histological changes was, like other factors, directly related to the air content of the lung tissue. Impulse oscillometry being a method used to analyze respiratory mechanics was applied to swine either sedated by means of diazepam (1.5 - 2.0 mg/kg b.w.) or non-sedated by medication but trained correspondingly. The animals were fixed in a canvas sling with openings for the limbs, avoiding stress, and the measuring system was adapted to the animal using a rigid face mask hermetically fitting to the animal''s head. A total of 26 animals was included in the studies to examine a variety of factors influencing the IOS parameters. The following parameters were considered: Respiratory rate (Af), tidal volume (Vt), the spectral parameters resistance (R), reactance (X) and coherence (K) at 5, 10, 15 and 20 Hz each (R5, ...R20, X5, ...X20, K5, ...K20) as well as the model parameters, central (Rz) and peripheral (Rp) resistance, lung compliance (Cl) and central inertance (Lz). A variability analysis involving five non-sedated, clinically healthy swine served to examine the reproducibility of the results of three IOS measurements either performed consecutively within a few minutes, or on three consecutive days at the same time of the day. During the brief period of a few minutes, the variability of the results of measurements, for most parameters, was due to inter-individual factors while in the case of an analysis over several days, the intra-individual share of variability increased. In the context of the IOS measurements performed in eleven clinically healthy, sedated swine over a period of 62 days, development in terms of age and body weight could only partially explain the variations of the IOS parameters taking place with growth. The influence of the time of the day on IOS parameters studied in eight clinically healthy, sedated swine was found to be small; coincidence with data given in literature, however, was seen as a tendency. The influence of diazepam sedation on the IOS parameters was examined in 16 clinically healthy swine. This medication resulted in a significant reduction of Af and Vt and improved quality of IOS measurements (K5, K10, K20). In seven clinically healthy, non-sedated swine, defined respiratory situations, i.e. bronchospasm and bronchodilatation were generated by aerosol inhalation of pharmacologically active substances such as carbachol and fenoterolhydrobromide and demonstrated by IOS measurements. This state of the bronchial system is characterized by the changes in IOS parameters found at the time of the bronchospasmic reaction, in particular the vehement rise of resistance in the lower frequency range (R5), the obvious drop in reactance, especially at 5 Hz and the noteworthy rise in the model parameter, Rp. Nine clinically healthy, sedated swine were examined first with their heads in a physiological and then, in a vertical position of their heads. The severe bending in the head-neck area produced an extrathoracic obstruction. Spectral resistance (R5 - R20) and the model parameter, Rz were significantly higher at a vertical position of the head. An experimental infection of seven sedated swine with Actinobacillus pleuropneumoniae served as a model to study the course of respiratory disease. The animals were subjected to regular IOS measurements over a period of 23 days. The results of IOS measurements performed 3 days p.i. (elevated resistance over the entire frequency range, vehement rise of Rz and Lz) reflected, above all, an involvement of the extrathoracic and central areas of the respiratory tract. As a result, the modifications of defined IOS parameters (intensification of negative frequency dependency, rise in Rp, drop in Cl) which were present at least as a tendency, indicated an additional involvement of the peripheral lung areas. The results of IOS measurements over a defined period were compared with the findings from lung sonography. High correlations between IOS parameters indicating peripheral changes and lung changes detected by sonography were demonstrated. Conclusions 1.) Both diagnostic methods studied may be used in swine and will provide a valuable completion of conventional diagnosis in the respiratory tract of this species. 2.) With a high probability, lung sonography will provide evidence of the presence of visible pathological-anatomical changes in the lung and their extent in the lung area that is accessible to sonography. 3.) Impulse oscillometry provides a complex of parameters that contain information about the functional state of the entire respiratory system. This state is dependent upon numerous physiological factors (among them position of the head, growth, time of the day), pharmacologically active substances administered (e.g. diazepam, carbachol, fenoterolhydrobromide) and the presence of respiratory disease (e.g. caused by Actinobacillus pleuropneumoniae). 4.) Since the two methods reflect different facts, i.e. the morphological (sonography) and the functional (impulse oscillometry) state of the respiratory system, they supply mutually supplementing information. 5.) Both diagnostic methods offer themselves above all for use in scientific research on swine. Owing to their non-invasive character, it is possible to handle test animals in a non-offensive way. 6.) In specific cases, lung sonography may also be used in the veterinary practitioner''s surgery, e.g. for the examination of animals kept for breeding.
188

Wearable Weather Forecast : Creating a forecast through iOS and Smart Clothes

Juzovitski, Emil January 2017 (has links)
Smart Clothes refers to clothes that have been embedded with computer devices. Items of the category can be used to inform an individual about his health. The technology can likewise be used to track an individuals surroundings. There are many possible uses for Smart Clothes. This thesis is based on the idea of creating a Smart Clothes item that can create weather forecasts independently. In order to create such system unique problems have to be solved. One major problem to overcome is realizing what a mobile application a mobile application has to do in a Smart Clothes system that predicts weather to the user. This thesis tries to answer the problem by examining how an existing weather forecast model can be implemented into an application to later display a forecast to a user. The study is built on an inductive approach and has a purpose to explore the necessary steps in developing a mobile application that predicts the weather. Presenting an implemented prototype is the purpose of the thesis. As such, the purpose becomes to create a mobile application that implements a weather forecast model and translates the created weather forecast into a UI suited for a mobile application. The weather forecast model should use atmospheric pressure differences to create a weather forecast. The goal of the thesis is to find out how the purpose can be achieved, how a mobile application should behave in order to assure that the Smart Clothes system can create a weather forecast for the user. A partial goal is to understand how atmospheric pressure should be converted into a weather forecast and how the weather forecast should be translated into a UI. The result is presented in the form of a prototype, an iOS application. The created prototype uses atmospheric pressure differences to create a weather forecast. The weather forecast is shown to the user through a intuitive user interface. The prototype is tested through a user-test and is evaluated through a thorough model with criteria. The evaluation shows that the prototype is easy to use and understand. There are in the same time improvements to be done for the future. Proposals have been given for improvements. The user-test has shown that the interest in the prototype is higher in situations where the user lacks internet connectivity. There is thus, a link between the prototype's usability and internet connectivity. In other words, people find the prototype to be of a big benefit as it can be used without Internet connectivity. / ”Smart Clothes” refererar till klädesplagg som har integrerats med dataenheter. Plagg i kategorin kan användas för att informera individen om hans hälsa. Teknologin kan likväl användas för att spåra individens omgivning. Det finns många möjliga användningsområden för Smart Clothes. Den här uppsatsen baseras på idén att skapa en Smart-klädesplagg som kan skapa väderprognoser självständigt. Uppsatsen försöker lösa problemet om vad en mobil applikation måste göra i ett Smart-klädessystem som förutspår väder för användaren. Studien bygger på en induktiv forskningsinsats och syftar på att utforska faktorer runt utvecklingen av en mobilapplikation, som är ansedd att integreras i klädesplagg. Att presentera en skapad prototyp är uppsatsens syfte. Detta ger att syftet blir att skapa en mobil applikation som implementerar en väderprognos-modell och omvandlar den skapade prognosen till ett användargränssnitt som passar en mobil-applikation. Väderprognos-modellen ska kunna konvertera skillnader i lufttryck till en väderprognos. Målet av uppsatsen är att finna hur syftet kan uppfyllas, hur en mobil-applikation ska agera för att säkerställa att Smart-klädessytemet kan skapa en väderprognos för användaren. Ett delmål är att förstå hur lufttryck ska omvandlas till en väderprognos och hur väderprognosen ska omvandlas till att användargränsnitt. I egenskap av resultat presenteras en prototyp iOS mobilapplikation. Den skapade prototypen använder skillnader i lufttryck för att skapa en väderprognos. Väderprognosen visas vidare till användaren genom ett intuitivt användargränssnitt. Prototypen testas genom ett användartest och utvärderas genom en utarbetad modell med kriterier. Evalueringen visar att den skapade prototypen är lätt att använda och förstå. Samtidigt finns fortfarande förbättringar att göra i framtiden. Rapporten ger förslag till förbättringar. Användartest indikerar att intresset att använda produkten är högre i situationer då användaren saknar internetanslutning. Således finns det en länk mellan produktens användbarhet och internetanslutning. Alltså, personer finner att prototypen är av stor nytta för att den kan användas även utan uppkoppling till internet.
189

Reaper – Toward Automating Mobile Cloud Communication

Ward, Daniel R 06 August 2013 (has links)
Mobile devices connected to cloud based services are becoming a mainstream method of delivery up-to-date and context aware information to users. Connecting mobile applications to cloud service require significant developer effort. Yet this communication code usually follows certain patterns, varying accordingly to the specific type of data sent and received from the server. By analyzing the causes of theses variations, we can create a system that can automate the code creation for communication from a mobile device to a cloud server. To automate code creation, a general pattern must extracted. This general solution can then be applied to any database configuration. Automating this process frees up valuable development time, allowing developers to make other parts of the application and/or backend service a better experience for the end user.
190

Mobilapplikationsutveckling med en användarcentrerad designfilosofi : enligt ISO 9241-210 / Mobile application development with a user-centred design philosophy : with ISO 9241-210

Aho, Jim, Höijer, Hans January 2012 (has links)
Marknaden för smartphones har vuxit stort under de senaste åren och även utveckling av applikationer till dessa. Då utveckling av applikationer för smartphones skiljer sig från traditionell utveckling så passar inte traditionella utvecklingsprocesser för utveckling till smartphones på ett optimalt sätt. Denna studie undersöker mobilapplikationsutveckling med fokus på användbarhet. Då det råder brist på systemutvecklingsprocesser för mobilapplikationsutveckling så vill denna studie utvärdera ISO standarden ”ISO 9241-210 – Användarcentrerad design för interaktiva system”. Denna standard är en samling av riktlinjer och krav för generell systemutveckling. Studien utvärderar därför lämpligheten att använda ISO 9241-210 för utveckling av mobilapplikationer, då fokus ligger på användbarhet. En prototyp för iPhone utvecklades med ISO 9241-210 som bas och utvärderades sedan för att se om användbarheten var acceptabel. Författarna utvärderade också hur ISO 9241-210 riktlinjer hade implementerats i utvecklingen av prototypen och även utvärderat om riktlinjerna i Apples App Design Strategies har motsvarande riktlinjer i ISO 9241-210. Slutsatsen är att ISO 9241-210 är en bra grund att stå på vid utveckling av mobilapplikationer men att det finns några riktlinjer som kan ges mer eller mindre fokus, beroende på projektets omfattning. / Program: Systemarkitekturutbildningen

Page generated in 0.0557 seconds