• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 12
  • Tagged with
  • 39
  • 17
  • 13
  • 10
  • 9
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

En undersökning om hur Robotsystem 70 skytten presterar i kyla

Karlsson, Andreas January 2009 (has links)
I denna uppsats har det studerats hur kyla påverkar Robot 70 skyttens prestanda. För att göra detta har en hypotesprövande metod använts. Hypotesen lyder: ”En robotskytts finmotorik påverkas av kyla så till den grad att träff inte är sannolik.” Hypotesen används till hjälp att svara på följande frågeställningar: Frågeställning 1: I vilken utsträckning påverkas robot 70-skyttens finriktningsförmåga av kyla? Frågeställning 2: Hur kan luftvärnsregementet förbättra nyttjandet av Robot 70 gruppens utrustning för att minska kylans påverkan på robotskyttens prestanda? Ett experiment har använts för att verifiera eller falsifiera hypotesen. Sju personer från Luftvärnsregementet har skjutit simulerade avfyringar inom- och utomhus, vid olika temperaturer. Resultatet från robotarna avfyrade inomhus vid 20°C hade en ungefärlig träffsannolikhet för direktträff på 94 %. Avfyringarna i segmentet med lägst uppmätta tumtemperaturer hade enligt mina mätningar en betydligt lägre träffsannolikhet för direktträff. Vad som verkar sänka temperaturen robotskyttens tumme mest, är värmeledning från robotsystemets styrspak. Slutsatsen är att detta verkar beror på att styrspaken är tillverkad av aluminium. Genom att isolera styrspaken kan det undvikas att skyttens tumme kyls ned och därmed minskar dennes träffsannolikhet. / In this essay it has been studied how cold environment can affect the gunner of the RBS 70. In this study, the method of testing a hypothesis has been used. Hypothesis: “The Gunner is affected by cold to such an extent that a hit is not probable” The hypothesis is used in helping to answer the following two questions: 1.      To what level is the RBS 70 Gunner affected by cold? 2.      How can the Swedish AD Regiment improve its use of equipment in order to   reduce the effects of cold weather, on the RBS 70 gunners’ ability to aim?  A test was performed to verify or falsify the hypothesis. Seven people from the Swedish AD Regiment fired simulated missiles both indoors and outdoors, in different temperatures. The results show that the missiles fired indoors at 20°C had an approximated direct hit-ratio of 94 percent. The firings where the thumb temperatures were the lowest had a lot lower direct hit ratio. The greatest issue lowering the gunners thumb temperature was the temperature of the joystick of the sight. The conclusions are that the joystick, which is made of aluminium, must be isolated to avoid cooling the gunners’ thumb. Otherwise it will be harder to hit the target at a low temperature.
22

Undersökning av komfortkyla i en kontorsfastighet

Eriksson, Daniel, Karlsson, Jörgen Unknown Date (has links)
The use of air-conditioning and comfort cooling in offices and stores has been increasing during recent years. Adnot, (2002) reports an increased use in commercial buildings by 200 % from 1990 to 2002. The increase is primarily due to the growing use of electrical equipment generating internal heat. The enhanced public demands of the indoor climate are yet another explanation to the increase. The main cooling method used is mechanical chillers based on vapor compression. Many of these cooling systems are old and will shortly become obsolete which gives the property holder a chance to improve in his cooling system. The office building Mercurius 12 in Karlstad operates activities that require comfort cooling. The cooling method used is conventional vapor compression which is distributed by an airborne system. The property consists of two buildings one built in 1939 and one in 1970. The property is 7700 m2 and accommodates one apartment, offices and stores. The property is currently housing 190 people. The aim of this report is that on a basis of life-cycle costs analyze how a change of cooling methods and cooling needs are connected to the Life-cycle costs of the cooling. The practicability of each change shall also be investigated. The calculation of the life-cycle costs and heat surpluses have been made using generally accepted formulas that has been outlined in Excel. All of the simulated measures to reduce the building's life-cycle costs in terms of internal heat and solar radiation pays off. The higher energy prices, the greater savings. The Cooling tower method is the chilling process that provides the minimum life-cycle costs, both with both air and waterborne distribution system. Vapor compression used with today’s energy prices provides comparatively to the other investigated methods a low life-cycle cost. The vapor compression method is however not as good if the energy price would get higher than today.
23

Energi- och bullerlösningar för fastigheter i tågtrafiken

Karlberg, Christian January 2009 (has links)
No description available.
24

Passiv kylning och uppvärmning av ventilationsluft med geoenergi

Runesson, Annie, Wilsson, Matilda January 2020 (has links)
På grund av den globala uppvärmningen kommer efterfrågan på kyla öka i framtiden och ett alternativ som kan tillgodose användarnas kylbehov men samtidigt sänka byggnadens energiförbrukning är passiv kylning med geoenergi. Furuliden är ett äldre- och gruppboende som tillhör det kommunala bostadsbolaget Allbohus som hyr ut lägenheter och lokaler i Alvesta kommun. Majoriteten av de boende i Furuliden tillhör grupper som är extra känsliga för värme och fastigheten har haft problem med att inomhustemperaturen ibland blivit för varm. Möjligheten att kyla och värma ventilationsluften passivt i Furuliden med hjälp av 8 parallella energibrunnarna som är installerade vid fastigheten har undersökts för ett billigare och ett dyrare alternativ. Detta har gjorts genom beräkningar, programmering samt insamling av offerter. Resultatet visar att energibrunnarna har kapacitet att tillgodose kylbehovet för de båda alternativen.
25

Fjärrkyla på LKAB : Absorptionskylmaskiner, frikyla och dess begränsningar

Kruukka, Erik January 2020 (has links)
LKAB behöver kyla till sina processer för att kunna förädla järnmalm. Ökad tillgång på elektronik och efterfrågan på komfortkyla breder ut sig i samhället idag, vilket leder till ett ökat kylbehov. Flertalet gamla kylanläggningar på LKAB i Kiruna börjar uppnå sin livslängd och behöver ersättas med nya maskiner och ny teknik. Då är utbyggnad av fjärrkylanätet som idag levererar kyla till KK4, KA3 och SAK-labb/kontor extra intressant. Istället för att ersätta gamla kylmaskiner i andra byggnader med nya kan man ansluta sig till de berörda fjärrkyalnätet. Det är ett nät där absorptionskylmaskiner och frikyla tillgodoser kylbehoven vilket även är ett bra val ur en miljömässig synpunkt då man nyttjar spillvärme. Idag klarar detta system av att leverera kyla till nuvarande kunder men frågan är hur mycket mer man kan ansluta till samma nät och vart begränsningarna ligger. Tittar man bara på kylmaskinerna ska man kunna ta ut 3MW kyla vilket är tre gånger så mycket som levereras idag. Begränsningarna ligger således inte där utan det är i de olika kretsarna till/från kylmaskinerna. I denna studie har mätvärden bakåt i tiden varit nödvändiga då endast frikyla använts under tidsperioden då detta examensarbete har utförts. Problem med loggning av data, felinställda givare och avsaknad av mätare har gjort att konkreta beräkningar uteblivit. Denna studie får ses som ett första steg mot en eventuell utökning av kylnätet. Konkreta förslag på hur man ska komma vidare för att kunna utnyttja nuvarande kylanläggnings hela potential tas upp i rapporten. Kan man i framtiden bygga ut fjärrkylnätet skulle man minska elanvändningen och underhållskostnaderna då man får ett färre antal kylmaskiner. / To refine iron ore products cooling is needed at LKAB. The increase of electronic devices and comfort cooling leads to higher cooling demands everywhere in society. Many old cooling machines soon are going to reach the end of their life span and needs to be replaced at LKAB in Kiruna. The development of the current district cooling grid is therefore interesting. Instead of replacing old machines in other buildings with new ones they can be connected to the existing grid. It is consisting of two absorption machines and free cooling and delivering cooling to the buildings KK4, KA3 and SAK-lab/office. The energy to the machines came from waste heat which is good for the efficiency and for the environment. Today the cooling system can manage the demands but how much can be connected to the grid in the future and where the limitations is for the current cooling system has yet no answer. The capacity of the absorption cooling is about 3MW and it is three times more than what is delivered today. So, the limitations are not the installed capacity but instead the different circuits in and out to the cooling machines. In this study previous measurements were important because only free cooling was used during this project. Problems with sensors, logging data and missing flowmeter made it impossible to do concrete calculations. Instead this study is a first step in the right direction to development of the district cooling system well as suggestions for future work. If the grid can be used to full potential the power consumption and the maintenance cost will decrease which is good for the environment and the economy.
26

Fjärrvärmedriven Absorptionskyla : En ekonomisk undersökning av olika spetslösningar

Strömqvist, Bodil January 2021 (has links)
This independent degree project has been implemented on behalf of FVB Sverige AB in collaboration Sundsvall Energi AB with the initial purpose of mapping manufacturers of hot water driven absorption chillers. After that, several technical solutions are examined to manage the peak load of a theoretical object which cannot produce the cooling power required with only an absorptions chiller, due to limitations in the district heating supply. The market study has shown that the supply of absorption chillers with drive temperatures of 70–90˚C is limited to a few manufacturers. World Energy offers a unit with drive temperatures of 70 ˚C and efficiency (COP) of 0,4. Due to limitations of district heating flow, a unit with drive temperature of 85 ˚C and efficiency of 0,77 is chosen. The technical solutions are dimensioned for a building with a peak power of 264 kilowatt, where the required peak load ranges from 31 to 39 kilowatt. The technical solutions examined are a solar collector system, tap water heat exchanger, and a conventional compressor driven chiller. The solar collectors are dependent on location but use no refrigerants that are affected by the F-gas regulation. The tap water solution consumes large flows of tap water, but the installation is simple. The conventional chiller is not location dependent but uses ozone degrading refrigerants and has a high cost of operation. From an economic perspective the technical solutions are equally profitable with a present net value of approximately 500 000 SEK and pay-back of 13 years. The examination has also shown that the present value is one million crowns in sales of heat and building after a ten-year period. In conclusion the conventional chiller has the biggest prerequisites to be used as a standardised solution for buildings with a bigger cooling load. Based on the technical and economical conditions.
27

En undersökning om två alternativa ventilationsaggregat med kyla på en befintlig byggnad : FTX värmepump med roterande värmeväxlare eller Sorptiv kyla

Punjani, Mariam, Huerta Olivares, Melanie January 2023 (has links)
This thesis is based on comparing two different air-ventilation systems with cooling in a building. Two systems are compared, the first one is FTX with heat pump and a rotating heat exchanger, and the second is a system with sorptive cooling. These systems use different types of energy – electricity and district heating for both cooling and heating. The FTX system (FTX 480) is produced from IV product and the system with sorptive cooling (DCI 3.0) is given from the company Munters. An FTX system recycles heat using a heat exchanger. Sorptive cooling is a technique that lowers the temperature by using district heating which cools the warm air coming from outside. The purpose is to study how effective these systems are looking at the costs of the systems and how they impact the climate. This is done by a life cycle cost analysis and a environmental implant analysis. This thesis is guided and has been given documentation by Statens fastighetsverk. The building that is mentioned in this study is Afrikahuset that is located in Uppsala. Product sheets for the systems have been produced and given by the companies IV product and Munters. Results show that system FTX 480 gives a lower cost and a lower climate effect compared to DCI 3.0 (sorptive cooling). Therefore, FTX 480 has the lowest total cost during the systems lifecycle, provides the lowest energy use on an annual basis and provides the best financial outcome over a 30-year time. In conclusion, a FTX system with heat pump and rotating heat pump is more useful than a system with sorptive cooling. / Examensarbetet jämför två olika ventilationsaggregat med olika metoder för luftburen kyla på en befintlig byggnad. Aggregaten ett från- och tilluftssystem (FTX) med värmepump och roterande värmeväxlare samt ett med Sorptiv kyla. Systemen använder olika energislag – el respektive fjärrvärme för både kyla och eftervärmning. Ett FTX aggregat återvinner värme i första hand med hjälp av en värmeväxlare och värmepump vid låga utetemperaturer, värmepumpen kan sedan användas för att kyla luften sommartid. Sorptiv teknik däremot återvinner även värmen med en värmeväxlare men kyler luften med hjälp av fjärrvärme i sekvens med befuktning och avtorkning. Syftet med arbetet är att undersöka hur ekonomiskt och hållbart dessa system är genom att analysera det ekonomiska utfallet samt klimatpåverkan hos båda systemen genom en livscykelkostnadsanalys och miljöpåverkansanalys. Undersökningen utförs med hjälp och underlag från Statens fastighetsverk. Den befintliga byggnaden är Afrikahuset, en utbildning- och forskningsverksamhet i Uppsala. Produktblad har tagits fram från företagen IV produkt samt Munters. En värdering av el och fjärrvärme resulterar i att en minskad elanvändning bidrar till en mer reducerad klimatpåverkan jämfört med fjärrvärme och att 90 procent av den energi som tillförs är återvunnen energi samt att fjärrvärmen normalt är dyrast. Det finns fördelar med värmedriven kyla då det råder stort värmeöverskott i kraftvärmeverken under sommarperioden vilket är bl.a. som en följd av elproduktionen. Studien visar att ett FTX system med värmepump och roterande värmeväxlare är mer ekonomiskt lönsamt (LCC) och bidrar till en mer positiv miljöpåverkan (LCA). Slutsatsen är att system FTX 480 har lägst totalkostnad under dess livstid, ger lägst klimatpåverkan på årlig basis och ger bäst ekonomiskt utfall unde
28

Feasibility study of evaporative cooling and toilet flushing using rainwater in a public building

Reig Moril, Claudia January 2023 (has links)
The project "Feasibility of evaporative cooling and toilet flushing using rainwater in a public building" combines rainwater harvesting with the evaporative cooling technology and toilet flushing and explores the practicality and viability of implementing this innovative system in the city of Gothenburg, Sweden. This study comprehensively investigates various aspects related to water and energy, and the entire system is computationally modelled using the Equation Engineering Solver (EES) software. The primary objective of the project is to assess the feasibility of utilizing harvested rainwater either for employing evaporative cooling for temperature control or for flushing toilets in a commercial building. By leveraging these sustainable practices, the project aims to reduce both water consumption and energy usage, thereby promoting environmental conservation and decreasing the ecological footprint. The study involves an in-depth analysis of several key aspects. Firstly, the local climate and rainfall patterns in Gothenburg are examined to evaluate the availability and adequacy of rainwater as a resource. Secondly, evaporative cooling technology is extensively investigated to determine its efficiency in cooling indoor spaces. The thermal dynamics and cooling potential of the system are analyzed, taking into account factors such as temperature differentials, humidity levels, and air circulation. The Equation Engineering Solver software is employed to simulate and compute the system's performance under varying conditions, allowing for predictions and optimization. For doing that, three cases with different conditions concerning the priorities of cooling and flushing necessities and the water volume in the two existing tanks in the installation have been developed in order to analyse the benefits they would bring in terms of energy and water savings. The comprehensive analysis of the technical and environmental feasibility of the three cases of study provides some advantageous results. Starting by analyzing the water aspect, in the first case, the one that prioritizes the cooling aspect while the water to fill the toilet flushing necessities is provided just if in the second tank there is any water left, a total of 37% and 10% of the requirements would be filled for the AHU and the toilet flushing respectively. Secondly, the case that still prioritizes the cooling demand but water for toilet flushing is provided as long as the storage tank is half full, meets 69% and 8% of the demand of the AHU and the flushing respectively. Laying aside the flushing aspect considering simply cooling in the third case, 75% of the supply within the AHU is met. When it comes to the thermal part, on the one hand, fractions provided by the new evaporative system are 22%, 32% and 49% respectively. This is due to the fact that almost every month in the three cases studied aims for extra cooling since the system does not hold the quantity of water required and therefore, an extra supply from the current cooling device is needed. Nevertheless, the system brings energy savings of 1005.3, 1510.4 and 2022.4 kWh per year. Furthermore, the energy consumption, in the three cases is very similar and low. The conclusions of the project, from a technical point of view, despite considering the fact that the requirements are not entirely met with actual medium contribution fractions either within the water and cooling aspects, with the existing water availability, the tanks and the pumps sizing and the existing AHU, the system is reliable and is capable to perform properly. Therefore, it can be concluded that it is technically feasible. Concerning the environmental feasibility, the key point of the study, depending on the case, the system would bring different savings. On the one hand, the water savings are 40.3, 47.0 and 8.2 m3 yearly for every case respectively, concluding that the second case is the one that would entail the highest water savings to the system. On the other hand, the energy savings hold values of 1005.3, 1510.4 and 2022.4 kWh annually, with the third case bringing the greatest value. Consequently, the three cases can be considered environmentally feasible since all of them achieve the overall objective of the project, the reduction of water and energy usage. However, depending on the savings’ preferences, either the second case with the highest reduction in water or the third case with the highest decrease in energy could be considered the best ones. From a general point of view, the second case could be the most suitable to set since it is the one that saves more water and moreover, it brings an energy reduction between the average values in the first and in the third case. These outcomes provide valuable insights and inform decision-making processes for the successful implementation and adoption of the system, and they guide future implementation strategies and contributions to sustainable urban development. / Projektet " Genomförbarhet för evaporativ kylning och spolning av WC med regnvatten " kombinerar insamling av regnvatten med evaporativ kylningsteknik och toalettspolning och utforskar möjligheten implementera detta innovativa system i Göteborgs stad, Sverige. Denna studie undersöker aspekter som vatten och energi. Systemet är modellerat med hjälp av programvaran Equation Engineering Solver (EES). Det primära syftet med projektet är att bedöma genomförbarheten av att använda uppsamlat regnvatten antingen för att endast evaporativ kyla för temperaturkontroll i en kommersiell byggnad eller för att spola toaletter med. Genom detta syftar projektet till att minska både vattenförbrukning och energianvändning, och därigenom främja miljö och minimera det ekologiska fotavtrycket. Studien gör en djupgående analys av flera nyckelaspekter. För det första undersöks det lokala klimatetoch nederbördsmönstren i Göteborg för att utvärdera tillgängligheten och tillräckligheten av regnvatten som resurs. För det andra undersöks tekniken för evaporativ kylning för att fastställa dess effektivitet vid kylning av inomhusutrymmen. Systemets kylningspotential analyseras med hänsyn till faktorer som temperaturskillnader, fuktighetsnivåer och luftcirkulation. Programvaran Equation Engineering Solver används för att simulera och beräkna systemets prestanda under varierande förhållanden, vilket möjliggör exakta förutsägelser och optimering.För att göra det har tre fall med olika förutsättningar avseende prioritering av kyl- och spolningsbehov samt vattenvolymen i de två befintliga tankarna i anläggningen testats för att analysera deras respektive energi- och vattenbesparingar. Utifrån vattenaspekten kunde det första fallet, den som prioriterar kyla medan vattnet för att fylla toalettens spolningsbehov tillhandahålls om det finns något vatten kvar i den mindre tanken, fylla totalt 37% och 10% av vattenbehovet för evaporativ kyla respektive toalettspolning. För det andra fallet, prioritering av kylbehovet men vatten för toalettspolning tillhandahålls så länge lagringstanken är halvfull, tillhandahåller 69 % och 8 % av behovet av evaporativ kyla respektive spolningen. För det tredje fallet, där allt vatten avses användas till evaporativ uppfylls 75 % av vattenbehovet. När det gäller den energimässiga aspekten tillhandahålls 22 %, 32 % respektive 49 % av det kylbehovs som krävs. Detta beror på att det under de tre studerade månaderna inte finns tillräckligt med vatten och därför krävs extrakyla. Systemet ger ändå en energibesparingar på 1005, 1510 respektive 2022 kWh per år.Projektets slutsatser, ur teknisk synvinkel, är att trots att man beaktar att hela behovet inte helt uppfylls vare sig inom vatten- och kylaspekterna, med den befintliga vattentillgången, tankarna och pumparnas dimensionering och den befintliga AHU:n är systemet pålitligt och kan fungera korrekt. Därför kan man dra slutsatsen att det är tekniskt genomförbart. När det gäller den miljömässiga genomförbarheten, den viktigaste punkten i studien, skulle systemet medföra olika besparingar beroende på fallet. Å ena sidan är vattenbesparingarna 40,3, 47,0 och 8,2 m3 årligen för varje fall, således är det andra fallet är det som skulle medföra störst vattenbesparing för systemet. Å andra sidan är energibesparingen störst för det tredje fallet. Följaktligen kan de tre fallen anses vara miljömässigt genomförbara eftersom de alla uppnår projektets övergripande mål, att minska vatten- och energianvändningen. Men beroende på besparingarnas preferenser kan antingen det andra fallet med den högsta minskningen av vatten eller det tredje fallet med den högsta minskningen av energi anses vara det bästa. Ur en allmän synvinkel kan det andra fallet vara det mest lämpliga att ställa in eftersom det är det som sparar mer vatten och dessutom ger det en energireduktion mellan medelvärdena i det första och i det tredje fallet. Slutligen ger dessa resultat ger värdefulla insikter hur framtida liknande system kan utformas för att bidrag till hållbar stadsutveckling.
29

Energieffektiviserande åtgärder för befintlig kontorsfastighet på Umestans företagspark : Energy-efficiency measures for existing office building at Umestans Business Park

Persson, Erica January 2016 (has links)
The work was conducted in the spring of 2016 on behalf of the ÅF Industry in Umeå. This project aimed to provide proposals on energy-saving measures for house 2 at Umestans Business Park based on the total specific purchased energy for 2015. Also for the 3rd floor in the same house suggestions on energy-saving measures were given. This was done with regard to the expected electricity use during 2016. Finally, an investigation on the possibility to classify the floors using of business-electricity was done.Initially was a literature study of today's classification system for buildings done. The focus was to see whether there is a possibility or not to classify leased office space. Both Swedish and international classification systems have been evaluated during the project.All the systems in the building were investigated and the total specific energy could be mapped. All the systems in the building were investigated and the total specific energy could be mapped. Based on the results of the operational-electricity that were emerged during the mapping of house 2, and based on the values of the electricity meter 83353 the business-electricity for floor 3 could be determined. Also for this area a mapping was made to see which areas the business-electricity went to.The results of the mapping of the building showed that the average energy consumption for the total specific purchased energy was 141,1 kWh/m2 per year. Of these districts heating stands for 63%. Of the total share of district heating 81% went to the radiators, this suggests that the building has large transmission losses. The inventory shows that the building's has a low use of electricity. This indicates that the technical systems were well installed with well-adapted operating times. The energy-saving measures that were found to reduce the building's losses were in the areas of windows, ventilation and solar shading. Energy-saving measures for the energy supplied were found in pumps, cooling and lighting.The result of floor 3 shows that the average use of business-electricity is at 36,36 kWh / m2 per year. Of these, 50% goes to lighting.From the results floor 3 could be classified to a Class B using the report "Energy performance of buildings - Energy Classification". To achieve a better classification requires change in the lightning on floor 3 as well as an analysis of any thinkable behavior change among the employees. / Examensarbetet utfördes under våren 2016 på uppdrag av ÅF Industry i Umeå. Detta projekt syftade till att ge förslag på energibesparande åtgärder för hus 2 vid Umestans företagspark baserat på den totalt specifikt köpta energin för år 2015. Även för våningsplan 3 i samma hus gavs förslag på energibesparande åtgärder. Detta skedde med avseende på den verksamhetsel som beräknas användas under år 2016. Slutligen utreddes möjligheten till att klassa våningsplanets användning av verksamhetsel.Inledningsvis utfördes en litteraturstudie på dagens klassningssystem för byggnader där fokus låg på att se till huruvida det finns en möjlighet att klassa hyrda kontorslokaler. Både Svenska och internationella klassningssystem har utvärderats under projektet.Sedan inventerades byggnadens samtliga system och den total specifik köpta energin kunde kartläggas. Utifrån de resultat för verksamhetsel som framkom under kartläggningen av hus 2 samt utifrån värden på elmätare 83353 kunde verksamhetselen för våningsplan 3 fastställas. Även för detta område gjordes en kartläggning för att se till vilka områden våningsplanets verksamhetsel gick.Resultatet för kartläggningen av byggnaden visade att den genomsnittliga energianvändningen för den totalt specifikt köpta energin var 141,1 kWh/m2,år. Av dessa utgjordes 63 % fjärrvärme. Av den totala andelen fjärrvärmen gick 81 % till radiatorerna, detta tyder på att byggnaden har stora transmissionsförluster. Den inventerade byggnadens låga användning av el visade på väl installerade tekniska system med väl anpassade drifttider. De energibesparande åtgärder som återfanns för att minska byggnadens förluster låg i områdena fönster, ventilation och solavskärmning. För den tillförda energin var det områdena pumpar, kyla och belysning som energibesparande åtgärder återfanns.Resultatet för våningsplan 3 visar att den genomsnittliga användningen av verksamhetsel ligger på 36,36 kWh/m2, år. Av dessa går 50 % till våningsplanets belysning.Ur resultatet kunde våningsplan 3 klassas till en klass B med hjälp av rapporten ”Byggnaders energiprestanda – Energiklassning”. För att nå en bättre klassning krävs åtgärder för våningsplanets belysning samt en analys av eventuella beteendeförändringar hos de anställda. / <p>roek0001</p>
30

An economic comparison between two district cooling systems in Halmstad

Le, Alex January 2014 (has links)
The supply of cooling has increased significantly in recent years, the trend shows that the increase will continue one reason is that the standard of living has increased, but EU has also set a requirement that energy consumption must be better at the same time. With “better” means more efficient and environmentally friendly. District cooling today uses either chillers or naturally available cold sources such as deep sea water, lake water or cold air. Cold air is, of course, only available when the seasons permit it and the cold air is not available when comfort cooling is needed for e.g. offices. The only alternative for areas that do not have a cold water source nearby is to use chillers. The most common chillers today are compressor chillers and absorption chillers. The most interesting chiller for the energy and environmental company HEM in Halmstad, is the absorption chiller which is driven by heat. HEM has, during the summer, surplus heat produced in Kristinehed plant which they want to use, they also have an increased inventory of waste during the summer which they get from the municipality of Halland. This heat is, of course, qualified to be used in the making of cold. Absorption chillers is today, however, not as common as compressor chillers which are capable of dealing with most cooling capacities, from small to large, and simultaneously works more or less flawlessly. Most of today’s absorption chillers are of a few hundred kW and upwards while there are no absorption chillers for the smaller effects, they are also very expensive and can have problems with crystallization of the absorbent if the operation is handled incorrectly. But it’s also expensive when it comes to piping of district cooling networks depending on where the pipes are desired, for example if it is the middle of town or over a grass field. A fictional project of the area Sannarp is used for a case study in this thesis where one investment alternative was to extend the existing district cooling pipes and another alternative was to invest in absorption chillers to meet the company's cooling demand. The results were obviously much affected by the area's layout and the distance to the first company starting from the existing pipe. The company's cooling demand also affected the results and the first alternatives investment cost could only be competitive with alternative 2 because the distance was just of the right length. If the distance to the company had been shorter, then the cooling demand for the same company has had to be less. The conclusion of the project was still in the end that and expansion of the current district cooling network to the company was the most feasible and economically advantageous.

Page generated in 0.0791 seconds