• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 137
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 140
  • 112
  • 28
  • 25
  • 25
  • 22
  • 21
  • 21
  • 20
  • 20
  • 20
  • 20
  • 19
  • 19
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação do uso do plasma rico em plaquetas no reparo da rotura do manguito rotador / Evaluation of platelet-rich plasma use in the repair of rotator cuff tear

Malavolta, Eduardo Angeli 16 January 2014 (has links)
O plasma rico em plaquetas (PRP) tem sido utilizado na ortopedia como método para melhorar a cicatrização tecidual. Existem poucos estudos com alto nível de evidência sobre o seu efeito no reparo do manguito rotador e os resultados são conflitantes, não havendo consenso sobre sua eficácia. O objetivo primário deste estudo foi avaliar o efeito do uso do PRP em pacientes submetidos ao reparo do manguito rotador por via artroscópica através da escala da University of California at Los Angeles (UCLA). A avaliação clínica através da escala de Constant-Murley, de dor através da escala visual analógica (EVA), a presença de rerroturas na análise da ressonância magnética (RM) e a ocorrência de complicações foram considerados desfechos secundários. Estudo prospectivo, randomizado, duplo-cego. Dois grupos com 27 pacientes (Grupo PRP e Grupo Controle) foram submetidos ao reparo artroscópico em fileira simples de âncoras, sendo que, no Grupo PRP, foi aplicado o concentrado de plaquetas ao final do procedimento. O PRP foi obtido por aférese, aplicado na consistência líquida, com adição de trombina autóloga. Foram incluídas apenas roturas de espessura completa do supraespinal com retração inferior a 30 mm. Os procedimentos foram realizados pelo mesmo cirurgião, entre setembro de 2008 e abril de 2012. Os desfechos foram avaliados através das escalas da UCLA, de Constant-Murley, EVA e pela RM, pré-operatoriamente e aos 3, 6 e 12 meses. A EVA foi aplicada adicionalmente no primeiro e sétimo dia. O nível de significância empregado foi de 5%. Os pacientes apresentaram melhora clínica significativa com o procedimento nos dois grupos (p < 0,001). Evoluíram de 13,63 ± 3,639 para 30,04 ± 4,528 no Grupo Controle e de 13,93 ± 4,649 para 32,30 ± 3,506 no Grupo PRP aos 12 meses (p = 0,046) de acordo com a escala da UCLA, com um poder de 84% e tamanho do efeito de 0,56. De acordo com a escala de Constant-Murley, os pacientes evoluíram de 47,37 ± 11,088 para 76,89 ± 13,198 no Grupo Controle e de 46,96 ± 11,937 para 83,26 ± 11,141 no Grupo PRP aos 12 meses (p=0,061). A avaliação aos 3 e 6 meses não demonstrou diferença significativa. A avaliação pela EVA não demonstrou diferença estatística em nenhum dos tempos de seguimento, evoluindo de 7,00 ± 1,939 no Grupo Controle e de 6,67 ± 1,617 no Grupo PRP no pré-operatório para 1,70 ± 2,127 e 1,04 ± 1,808, respectivamente, aos 12 meses (p = 0,220). Na análise pela RM, o Grupo Controle apresentou uma rerrotura completa e quatro parciais, enquanto o Grupo PRP apresentou duas rerroturas parciais (p = 0,42). Ocorreu um caso de rigidez articular em cada grupo (p = 1). O PRP obtido por aférese, aplicado na consistência líquida e com adição de trombina propiciou melhores resultados pela escala da UCLA aos 12 meses de pós-operatório / Platelet-rich plasma (PRP) has been used in orthopedics as a method to enhance tissue healing. There are few studies with a high level of evidence about its effect on rotator cuff repair, and the results are conflicting, with no consensus about its effectiveness. Clinical assessment as measured by the UCLA (University of California at Los Angeles) shoulder rating scale was established as the primary outcome. The secondary outcomes included clinical assessment on the Constant-Murley scale, pain as measured by a visual analog scale (VAS), the retear rate assessed by magnetic resonance imaging (MRI) and the complication rate. A prospective, randomized, doubleblind trial was conducted. Two groups of 27 patients (PRP Group and Control Group) were subjected to arthroscopic single-row repair. Liquid PRP prepared by apheresis was applied to the PRP Group at the end of the surgical procedure, with autologous thrombin. Complete supraspinatus tears with retraction less than 30 mm were included. The procedures were performed by the same surgeon between September 2008 and April 2012. Outcomes were assessed using UCLA and Constant-Murley scales, VAS and magnetic resonance imaging preoperatively and at 3, 6 and 12 months. The VAS was also applied on days one and seven. The significance level was 5%. The two groups of patients exhibited significant clinical improvement (p < 0.001). The score on the UCLA scale increased from 13.63 ± 3.639 to 30.04 ± 4.528 and from 13.93 ± 4.649 to 32.30 ± 3.506 in the Control and PRP groups, respectively, between the preoperative assessment and after 12 months (p=0.046), with a 84% power and a 0.56 effect size. The score on Constant-Murley scale increased from 47.37 ± 11.088 to 76.89 ± 13.198 in the Control Group and from 46.96 ± 11.937 to 83.26 ± 11.141 in the PRP Group (p = 0.061). Assessment at 3 and 6 months did not identify significant differences. The VAS did not statistically differ at any investigated timepoint and varied from 7.00 ± 1.939 and 6.67 ± 1.617 before surgery to 1.70 ± 2.127 and 1.04 ± 1.808 at the 12-month assessment in the Control and PRP groups, respectively (p = 0.220). The Control Group exhibited one case of complete and four of partial retears, and the Group PRP exhibited two cases of partial retears (p = 0.42). PRP prepared by apheresis, applied in the liquid state with thrombin, promoted better results on the UCLA scale 12 months after surgery
122

Avaliação do uso do plasma rico em plaquetas no reparo da rotura do manguito rotador / Evaluation of platelet-rich plasma use in the repair of rotator cuff tear

Eduardo Angeli Malavolta 16 January 2014 (has links)
O plasma rico em plaquetas (PRP) tem sido utilizado na ortopedia como método para melhorar a cicatrização tecidual. Existem poucos estudos com alto nível de evidência sobre o seu efeito no reparo do manguito rotador e os resultados são conflitantes, não havendo consenso sobre sua eficácia. O objetivo primário deste estudo foi avaliar o efeito do uso do PRP em pacientes submetidos ao reparo do manguito rotador por via artroscópica através da escala da University of California at Los Angeles (UCLA). A avaliação clínica através da escala de Constant-Murley, de dor através da escala visual analógica (EVA), a presença de rerroturas na análise da ressonância magnética (RM) e a ocorrência de complicações foram considerados desfechos secundários. Estudo prospectivo, randomizado, duplo-cego. Dois grupos com 27 pacientes (Grupo PRP e Grupo Controle) foram submetidos ao reparo artroscópico em fileira simples de âncoras, sendo que, no Grupo PRP, foi aplicado o concentrado de plaquetas ao final do procedimento. O PRP foi obtido por aférese, aplicado na consistência líquida, com adição de trombina autóloga. Foram incluídas apenas roturas de espessura completa do supraespinal com retração inferior a 30 mm. Os procedimentos foram realizados pelo mesmo cirurgião, entre setembro de 2008 e abril de 2012. Os desfechos foram avaliados através das escalas da UCLA, de Constant-Murley, EVA e pela RM, pré-operatoriamente e aos 3, 6 e 12 meses. A EVA foi aplicada adicionalmente no primeiro e sétimo dia. O nível de significância empregado foi de 5%. Os pacientes apresentaram melhora clínica significativa com o procedimento nos dois grupos (p < 0,001). Evoluíram de 13,63 ± 3,639 para 30,04 ± 4,528 no Grupo Controle e de 13,93 ± 4,649 para 32,30 ± 3,506 no Grupo PRP aos 12 meses (p = 0,046) de acordo com a escala da UCLA, com um poder de 84% e tamanho do efeito de 0,56. De acordo com a escala de Constant-Murley, os pacientes evoluíram de 47,37 ± 11,088 para 76,89 ± 13,198 no Grupo Controle e de 46,96 ± 11,937 para 83,26 ± 11,141 no Grupo PRP aos 12 meses (p=0,061). A avaliação aos 3 e 6 meses não demonstrou diferença significativa. A avaliação pela EVA não demonstrou diferença estatística em nenhum dos tempos de seguimento, evoluindo de 7,00 ± 1,939 no Grupo Controle e de 6,67 ± 1,617 no Grupo PRP no pré-operatório para 1,70 ± 2,127 e 1,04 ± 1,808, respectivamente, aos 12 meses (p = 0,220). Na análise pela RM, o Grupo Controle apresentou uma rerrotura completa e quatro parciais, enquanto o Grupo PRP apresentou duas rerroturas parciais (p = 0,42). Ocorreu um caso de rigidez articular em cada grupo (p = 1). O PRP obtido por aférese, aplicado na consistência líquida e com adição de trombina propiciou melhores resultados pela escala da UCLA aos 12 meses de pós-operatório / Platelet-rich plasma (PRP) has been used in orthopedics as a method to enhance tissue healing. There are few studies with a high level of evidence about its effect on rotator cuff repair, and the results are conflicting, with no consensus about its effectiveness. Clinical assessment as measured by the UCLA (University of California at Los Angeles) shoulder rating scale was established as the primary outcome. The secondary outcomes included clinical assessment on the Constant-Murley scale, pain as measured by a visual analog scale (VAS), the retear rate assessed by magnetic resonance imaging (MRI) and the complication rate. A prospective, randomized, doubleblind trial was conducted. Two groups of 27 patients (PRP Group and Control Group) were subjected to arthroscopic single-row repair. Liquid PRP prepared by apheresis was applied to the PRP Group at the end of the surgical procedure, with autologous thrombin. Complete supraspinatus tears with retraction less than 30 mm were included. The procedures were performed by the same surgeon between September 2008 and April 2012. Outcomes were assessed using UCLA and Constant-Murley scales, VAS and magnetic resonance imaging preoperatively and at 3, 6 and 12 months. The VAS was also applied on days one and seven. The significance level was 5%. The two groups of patients exhibited significant clinical improvement (p < 0.001). The score on the UCLA scale increased from 13.63 ± 3.639 to 30.04 ± 4.528 and from 13.93 ± 4.649 to 32.30 ± 3.506 in the Control and PRP groups, respectively, between the preoperative assessment and after 12 months (p=0.046), with a 84% power and a 0.56 effect size. The score on Constant-Murley scale increased from 47.37 ± 11.088 to 76.89 ± 13.198 in the Control Group and from 46.96 ± 11.937 to 83.26 ± 11.141 in the PRP Group (p = 0.061). Assessment at 3 and 6 months did not identify significant differences. The VAS did not statistically differ at any investigated timepoint and varied from 7.00 ± 1.939 and 6.67 ± 1.617 before surgery to 1.70 ± 2.127 and 1.04 ± 1.808 at the 12-month assessment in the Control and PRP groups, respectively (p = 0.220). The Control Group exhibited one case of complete and four of partial retears, and the Group PRP exhibited two cases of partial retears (p = 0.42). PRP prepared by apheresis, applied in the liquid state with thrombin, promoted better results on the UCLA scale 12 months after surgery
123

Efeito da dor crônica no ombro no comportamento motor de uma tarefa de apontamento com o corpo inteiro / Effect of chronic shoulder pain on the motor behavior of a whole body pointing

Sousa, Marcello Ferraz de Campos de 19 October 2018 (has links)
Em indivíduos saudáveis o desempenho motor e os parâmetros cinemáticos e espaçotemporais da tarefa de alcance já estão descritos na literatura. Até o momento nenhum estudo investigou a influência da dor crônica no ombro nessas variáveis durante a tarefa de apontamento com o corpo todo em diferentes demandas, e nem estabeleceram como é o comportamento motor. Por este motivo, o objetivo do presente estudo foi caracterizar o comportamento motor de uma tarefa de apontamento em indivíduos com dor no ombro e avaliar parâmetros de padrão de movimento, desempenho motor e equilíbrio. Trata-se de um estudo transversal realizado no Laboratório de Bioengenharia Elétrica da Escola Politécnica da USP. Participaram do estudo 20 sujeitos, sendo 11 no grupo controle (GC) e 9 no grupo com dor (GD). O experimento consistiu em realizar um alcance em três angulações distintas (menor, igual e maior que 90°) em duas velocidades (normal e rápida). Foram coletados dados de cinemática e plataforma de força. As principais medidas foram (1) índice de retidão (IR); (2) tempo de reação e movimento (3) deslocamentos angulares e lineares (4) COP e COM. Os resultados mostraram que o GD apresentou pior IR, maior tempo de reação e de movimento, os deslocamentos lineares e angulares foram mais estereotipados, os deslocamentos do COM e a velocidade de deslocamento do COP foram menores e as estratégias de equilíbrio foram menos utilizadas, gerando manutenção do controle em bloco. Desta forma, conclui-se que o comportamento motor é alterado no GD e as variáveis de padrão de movimento, desempenho motor e de equilíbrio foram piores na comparação com indivíduos saudáveis / In healthy subjects the motor performance and the kinematic parameters and spatiotemporal parameters of the task of reaching have already been described in the literature. Until now no study has investigated the influence of chronic shoulder pain on these variables during whole body pointing in different demands and did not establish how motor behavior works. For this reason, the aim of the present study was to characterize the motor behavior of a pointing task in individuals with shoulder pain and to evaluate patterns of movement pattern, motor performance and balance. This is a cross-sectional study conducted at the Bioengineering Laboratory of the Polytechnic School of USP. Twenty subjects participated in the study, being 11 in the control group (CG) and 9 in the pain group (PG). The experiment consisted in achieving a range in three distinct angles (smaller, equal and greater than 90 °) in two speeds (normal and fast). Kinematics and force platform data were collected. The main measures were (1) straightness index (RI); (2) reaction time and movement (3) angular and linear displacements (4) COP and COM. The results showed that the GD presented worse IR, longer reaction time and movement, linear and angular displacements were more stereotyped, the COM displacements and the COP displacement velocity were smaller and the equilibrium strategies were less used, generating maintenance of block control. However, we conclude that motor behavior is altered in GD and the variables of movement pattern, motor performance and balance were worse in comparison with healthy individuals
124

Avaliação comparativa entre os reparos das lesões agudas e crônicas do manguito rotador em estudo experimental / Comparative evaluation between acute and chronic rotator cuff tear repairs in an experimental model

Cavinatto, Leonardo Muntada 03 February 2016 (has links)
Universidade de São Paulo, Faculdade de Medicina; 2015. Introdução: Diante de uma rotura traumática do manguito rotador, não há evidência direta que comprove que os reparos realizados precocemente são mais eficazes que aqueles realizados tardiamente. Para abordar essa questão, ensaios biomecânicos e de morfometria óssea foram realizados após roturas extensas do manguito rotador realizadas precocemente (lesões agudas) e tardiamente (lesões crônicas), mediante a utilização de um modelo experimental em ratos. Método: 30 ratos adultos da raça Wistar foram aleatoriamente divididos em três grupos (I, II e III) e submetidos à secção completa dos tendões do supraespinal e infraespinal nos ombros esquerdos. Após oito semanas, nos animais dos grupos I e II, os tendões rotos pertencentes aos ombros esquerdos foram cirurgicamente reparados, e os tendões equivalentes nos ombros direitos foram seccionados e imediatamente reparados. Quatro semanas após os reparos (para os ratos do grupo II) ou oito semanas após os reparos (para os ratos do grupo I), os animais foram submetidos à eutanásia. Os ratos do grupo III foram submetidos à eutanásia oito semanas após a cirurgia de secção tendínea sem que houvesse ocorrido o reparo dos tendões rotos. Os ombros direitos dos animais do grupo III permaneceram intactos e serviram como controles. Após a eutanásia, todos os ratos tiveram seus ombros dissecados e os espécimes foram encaminhados para a realização de testes biomecânicos e de microtomografia computadorizada. Resultados: Para todos os parâmetros biomecânicos analisados, foram encontradas interações significantes referentes aos fatores tempo de cicatrização e reparo, considerando os reparos precoces e tardios. Com relação ao tendão supraespinal para o período de oito semanas de cicatrização, a força máxima até a falha foi significantemente maior nos reparos precoces em comparação aos reparos tardios (31,81 ± 3,86N vs 19,36 ± 6,14N; p < 0,001), bem como a rigidez (17,22 ± 4,35N/mm vs 10,85 ± 4,25N/mm; p=0,034), a tensão máxima até a falha (4,49 ± 2,02N/mm2 vs 1,97 ± 0,61N/mm2; p < 0,001) e o módulo de elasticidade (13,72 ± 5,29N/mm2 vs 6,47 ± 2,42 N/mm2; p=0,033). Com relação ao tendão infraespinal com oito semanas de cicatrização, a força máxima até a falha foi significantemente maior nos reparos precoces em comparação aos reparos tardios (21,26 ± 3,94N vs 12,74 ± 2,87N; p=0,005), assim como a rigidez (12,86 ± 2,65N/mm vs 7,21 ± 3,30N/mm; p=0,014). O grupo com reparo tardio com oito semanas de cicatrização obteve resultados nos testes biomecânicos semelhantes aqueles obtidos nos testes do grupo com lesão sem reparo com oito semanas de cicatrização. A avaliação microtomográfica não apresentou diferenças significantes na microarquitetura óssea entre os reparos realizados precocemente e tardiamente. Conclusões: Os resultados desse estudo demonstram que as roturas extensas do manguito rotador reparadas precocemente produzem um tecido cicatricial na junção ósteo-tendínea com melhores propriedades biomecânicas que as roturas reparadas tardiamente. Porém, ao analisar a morfometria óssea da porção proximal do úmero, verificou-se que os efeitos são equivalentes, tanto para os reparos realizados tardiamente quanto para os reparos realizados precocemente / Introduction: In the event of a traumatic rotator cuff tear, there is no direct evidence that supports early over late surgical repair. To address this knowledge gap, biomechanical and bone morphometry outcomes were assessed following early (acute) and late (chronic) massive rotator cuff tear repairs in an experimental rat model. Methods: 30 adult Wistar rats were randomly divided into three groups (I, II and III), then subjected to combined supraspinatus and infraspinatus tendon tears of the left shoulder. Eight weeks following the injury, animals from groups I and II had the tendons of the injured shoulder surgically repaired. In addition, these animals were subjected to the same injury on the contralateral shoulder, which was immediately repaired. The rats were euthanized four weeks (group II) or eight weeks (group I) following the repairs. Group III was euthanized eight weeks following the injury, without surgical repair of the left shoulder, and the intact right shoulders of this group were used as controls. Tissues from all groups were harvested and subjected to biomechanical testing and bone morphometry analysis. Results: In all biomechanical parameters analyzed, a significant interaction was observed between healing and repair timing. For the supraspinatus tendon with eight weeks healing time, biomechanical properties were significant increased in the early repair group compared to the late repair group, including maximum load to failure (31,81 ± 3,86N vs 19,36 ± 6,14N; p < 0,001), stiffness (17,22 ± 4,35N/mm vs 10,85 ± 4,25N/mm; p=0,034), maximum stress to failure (4,49 ± 2,02N/mm2 vs 1,97 ± 0,61N/mm2; p < 0,001) and modulus of elasticity (13,72 ± 5,29N/mm2 vs 6,47 ± 2,42 N/mm2; p=0,033). For the infraspinatus tendon with eight weeks healing time, biomechanical properties were also significantly increased in the early repair group, including maximum load to failure (21,26 ± 3,94N vs 12,74 ± 2,87N; p=0,005) and stiffness (12,86 ± 2,65N/mm vs 7,21 ± 3,30N/mm; p=0,014). There were no significant differences between the late repair with eight weeks of healing time and the group without surgical repair for supraspinatus and infraspinatus tendons. Concerning bone morphometry of the humeral head, no significant differences were observed when comparing early and late repair groups. Conclusions: The results from this study indicate that early surgical repair of a massive rotator cuff tear leads to increased biomechanical properties of the tissue after healing. However, proximal humerus bone morphometry was unaffected by surgical repair timing
125

Acurácia da ressonância magnética na detecção de roturas e de instabilidade na porção intra-articular do tendão da cabeça longa do bíceps braquial em pacientes submetidos a reparo do manguito rotador / Accuracy of magnetic resonance imaging in the detection of tears and instability in the intra-articular portion of the long head of biceps tendon in patients undergoing rotator cuff repair

Baptista, Eduardo 05 February 2019 (has links)
A literatura a respeito da capacidade da ressonância magnética em avaliar as afecções do tendão da cabeça longa do bíceps é escassa, a despeito da importância destas condições na gênese da dor e da disfunção do ombro. O objetivo primário deste estudo foi analisar o desempenho diagnóstico da ressonância magnética na detecção de roturas e de instabilidade na porção intra-articular deste tendão, comparando os achados de imagem com os dados de cirurgia artroscópica (padrão de referência). Foram objetivos secundários determinar as reprodutibilidades intraobservador e interobservador, avaliar a capacidade da ressonância magnética em classificar os tipos de rotura, avaliar a acurácia da associação entre alterações tendíneas e roturas do manguito rotador na instabilidade, além de pesquisar fatores preditores da acurácia da ressonância magnética. Foi realizado estudo transversal, com segmentos retrospectivo e prospectivo. Os critérios de inclusão foram indicação de cirurgia artroscópica do ombro para reparo do manguito rotador e exame de ressonância magnética préoperatória. Os critérios de exclusão foram: manipulação cirúrgica pregressa no ombro estudado; exames com imagens de má qualidade; intervalo entre exame pré-operatório e procedimento cirúrgico superior a um ano; indicação de técnica cirúrgica por via aberta. Foram estudados 100 ombros de 98 pacientes, operados consecutivamente de abril de 2013 a março de 2017 (47 meses). Todos os pacientes realizaram ressonância magnética de 1,5 Tesla em nossa instituição, sem utilização de contraste intra-articular. Todas as cirurgias foram realizadas pelos mesmos 3 cirurgiões, com 10 a 12 anos de experiência em cirurgia do ombro e cotovelo. Dois radiologistas, com 4 e 8 anos de experiência na área musculoesquelética, avaliaram as imagens de todos os exames, de forma independente e sem conhecimento prévio dos resultados intra-operatórios. Os mesmos casos foram revistos por um dos radiologistas, 4 meses após a primeira análise. Nossos resultados demostraram desempenho diagnóstico moderado da ressonância magnética para detecção de roturas do bíceps, com sensibilidades entre 71,1% a 73,3%, especificidades de 72,7% e acurácia entre 72 e 73%. A reprodutibilidade interobservador foi substancial (coeficiente Kappa de 0,62 a 0,69) e a reprodutibilidade intraobservador foi substancial ou quase perfeita na avaliação das roturas (coeficiente Kappa de 0,74 a 0,82). Houve correlação moderada entre os métodos para classificar o tipo de rotura (coeficiente Kappa de 0,38 a 0,47). Quando consideradas roturas completas, foram calculadas especificidades entre 75,0% e 95,7%, porém sensibilidades de 55,6% a 66,7%. Para o diagnóstico de instabilidade, observa-se sensibilidade de 52,4% a 59,1%, especificidade de 70,5% a 84% e acurácia de 64,4% a 69,5%. A avaliação combinada do deslocamento tendíneo e das roturas do manguito rotador resultou em sensibilidades de 17,5% a 47,7% e especificidades de 72,7% a 90,7%. A reprodutibilidade interobservador foi substancial (coeficiente Kappa de 0,59 a 0,7) e a reprodutibilidade intraobservador foi substancial ou quase perfeita (coeficiente Kappa de 0,76 a 0,80) para avaliação de instabilidade. Não identificamos fatores preditores para acurácia da ressonância magnética na pesquisa dessas afecções / There is paucity of literature regarding the performance of magnetic resonance imaging to assess long head of the biceps tendon disorders, despite the importance of such disorders in the genesis of pain and shoulder dysfunction. The primary objective of this study was to analyze the diagnostic performance of magnetic resonance imaging in the detection of tears and instability of the intra-articular portion of this tendon, comparing imaging findings with data from arthroscopic surgery (reference standard). Secondary objectives were to determine intraobserver and interobserver reproducibility; to evaluate the capability of MRI to classify types of tears; to evaluate the accuracy of the association between tendon displacement and rotator cuff tears to predict instability; to investigate predictive factors of magnetic resonance accuracy. A cross-sectional study was carried out, with retrospective and prospective segments. Inclusion criteria were indication of arthroscopic shoulder surgery for rotator cuff repair and preoperative magnetic resonance imaging. Exclusion criteria were: previous surgical manipulation in the studied shoulder; poor quality images; interval between preoperative examination and surgical procedure above one year; and indication of open surgical technique. We studied 100 shoulders of 98 consecutively operated patients from April 2013 to March 2017 (47 months). All patients underwent magnetic resonance imaging at our institution, using a 1.5 Tesla scanner, without use of intra-articular contrast. All surgeries were performed by the same 3 surgeons, with 10 to 12 years of experience in shoulder and elbow surgery. Two radiologists, with 4 and 8 years of experience in musculoskeletal radiology, evaluated the images independently and without previous knowledge of the intraoperative results. The same cases were reviewed by one of the radiologists, 4 months after the first analysis. Our results demonstrated a moderate diagnostic performance of MRI to detect biceps tears, with sensitivities between 71.1% and 73.3%, specificities of 72.7% and accuracy between 72 and 73%. Interobserver reproducibility was substantial (Kappa coefficient ranged from 0.62 to 0.69), and intraobserver reproducibility was substantial or almost perfect (Kappa coefficient ranged from 0.74 to 0.82). There was moderate correlation between the methods when classifying the type of tear (Kappa coefficient ranged from 0.38 to 0.47). Regarding full-thickness tears, specificities were calculated between 75.0% and 95.7%, but sensitivities from 55.6% to 66.7%. For the diagnosis of instability, sensitivity was from 52.4% to 59.1%, specificity was from 70.5% to 84% and accuracy was from 64,4% to 69,5%. The combined evaluation of tendon displacement and rotator cuff tears resulted in sensitivities from 17.5% to 47.7% and specificities from 72.7% to 90.7%. Interobserver reproducibility was substantial (Kappa coefficient ranged from 0.59 to 0.7), and intraobserver reproducibility was substantial or almost perfect (Kappa coefficient ranged from 0.76 to 0.80) for instability assessment. We did not identify predictive factors for magnetic resonance imaging accuracy in the assessment of these conditions
126

Dinamometria isocinética dos músculos rotadores internos e adutores do ombro em nadadores. Estudo comparativo entre nados de braçadas alternadas e simultâneas / Isokinetic dynamometry of the internal rotators and adductors muscles of the shoulder in swimmers. Comparative study of swimming strokes alternate and simultaneous

Secchi, Leonardo Luiz Barretti 04 July 2011 (has links)
OBJETIVO: Comparar a força muscular dos rotadores internos e adutores do ombro (propulsores da natação) dos estilos com braçada simultânea (borboleta e peito) e estilos com braçada alternada (livre e costas). CASUÍSTICA E MÉTODOS: Foram avaliados 46 ombros de nadadores federados dos estilo livre e costas (nado alternado GNA) com idade de 21,8 ± 3,8 anos; peso de 71,2 ± 10,0 kg, altura de 177,6 ± 8,5 cm e IMC= 22,3 ± 1,3; 44 ombros de nadadores federados dos estilos peito e borboleta (nado simultâneo - GNS) com idade de 20,3 ± 4,5 anos; peso de 70,5 ± 9,3 kg, altura 167,2 ± 37,6 cm e IMC= 22,6 ± 1,9; 28 ombros de nadadores recreacionais (grupo recreacional GR) com idade de 24,5 ± 4,5 anos; peso de 70,8 ± 16 kg, altura de 173,4 ± 9,2 cm e IMC= 23,3 ± 3,9 e 42 ombros de indivíduos controle (Grupo - GC) com idade de 25,8 ± 3,5 anos; peso de 68,7 ± 11,2 kg, altura 171,9 ± 9,3 cm e IMC= 23,2 ± 2,6. Todos foram avaliados no dinamômetro isocinético Biodex Multi-joint System 3® (Shirley, NY, USA) nas velocidades de 60º/segundo e 300º/segundo. Foram avaliados os movimentos de adução e rotação interna. As variáveis estudadas foram pico de torque corrigido pelo peso corpóreo (PTPC), trabalho total (TT) e relação agonista/antagonista. RESULTADOS: Não houve diferença na musculatura adutora entre os grupos GNS e GNA nas variáveis PTPC (GNS = 114,4 Nm e GNA = 109,4 Nm) e TT (GNS = 642,9J e GNA = 641,5J). Não houve diferença na relação abdução/adução do ombro entre GNS (67,4%) e GNA (68,3%). Não houve diferença na musculatura rotadora interna entre os grupos GNS e GNA nas variáveis PTPC (GNS = 66,4Nm e GNA = 63,4Nm) e TT (GNS = 517,4J e GNA 526,7J). Não houve diferença na relação rotação externa e rotação interna o ombro entre GNS (65,7%) e GNA (61,5%). CONCLUSÃO: Não há diferença na força muscular dos músculos adutores e rotadores internos do ombro quando se compara nados com braçadas simultâneas e alternadas / OBJECTIVE: To compare the muscle strength of internal rotators and adductors of the shoulder (of the propellants swimming) of styles with simultaneous stroke (butterfly and breaststroke) and stroke with alternating colors (free and back). PATIENTS AND METHODS: We evaluated 46 shoulders of competitive swimmers of freestyle and back (alternating swimming - GNA) aged 21.8 ± 3.8 years, weight 71.2 ± 10.0 kg, height 177.6 ± 8.5 cm and BMI = 22.3 ± 1.3. 44 shoulders of competitive swimmers of styles breast and butterfly (swimming simultaneously - GNS) aged 20.3 ± 4.5 years, weight 70.5 ± 9.3 kg, height 167.2 ± 37.6 cm and BMI = 22.6 ± 1.9. Shoulders of 28 recreational swimmers (group recreational - GR) aged 24.5 ± 4.5 years, weight 70.8 ± 16 kg, height 173.4 ± 9.2 cm and BMI = 23.3 ± 3, 9:42 shoulders of individuals (control group - CG) aged 25.8 ± 3.5 years, weight 68.7 ± 11.2 kg, height 171.9 ± 9.3 cm and BMI = 23, 2 ± 2.6. All were assessed using an isokinetic dynamometer Biodex Multi-joint System 3 ® (Shirley, NY, USA) at 60 ° / second and 300 º / second. We evaluated the movements of adduction and internal rotation. The variables were peak torque corrected for body weight (PTPC), total work (TW) and agonist / antagonist. RESULTS: There was no difference in the adductor muscle between the groups in the variables and GNA GNS PTPC (Nm) (GNS = 114.4 and 109.4 = GNA) and TT (J) (GNS = 642.9 and 641.5 = GNA). There was no difference in the abduction / adduction (%) of the shoulder between GNS (GNS = GNA = 67.4 and 68.3). There was no difference in the internal rotator muscles between the groups in the variables and GNA GNS PTPC (Nm) (GNS and GNA = 66.4 = 63.4) and TT (J) (GNS = 517.4 and 526.7 GNA). There was no difference in the external rotation and internal rotation (%) of the shoulder between GNS (GNS = GNA = 65.7 and 61.5). CONCLUSION: No difference in muscle strength of adductor muscles and internal rotators of the shoulder when comparing births with simultaneous and alternate strokes
127

Efeito da estimulação elétrica nervosa transcutânea (TENS) no tratamento da dor e capacidade funcional do ombro de pacientes com doença renal crônica / Effect of transcutaneous electrical nerve stimulation (TENS) in the treatment of pain and functional capacity shoulder of patients with chronic kidney disease

Bertoli, Patricia Ribeiro 04 November 2009 (has links)
INTRODUÇÃO: A doença renal crônica (DRC) favorece o desenvolvimento de inúmeras complicações entre elas a amiloidose. Nos ombros os depósitos de amilóide desencadeiam reações inflamatórias e dor intensa o que compromete a qualidade de vida dos pacientes acometidos. As propostas terapêuticas para o tratamento dessa complicação são escassas. OBJETIVO: O objetivo do presente estudo foi avaliar o efeito da estimulação elétrica nervosa transcutânea (do inglês, TENS) no tratamento da dor e capacidade funcional do ombro e dos fatores relacionados à qualidade de vida em pacientes com DRC. MÉTODOS: Trinta pacientes foram avaliados 5 vezes num período de 6 semanas. Na 1ª semana, o aparelho foi programado para não transmitir a corrente elétrica (placebo) e nas 5 semanas subseqüentes, utilizamos corrente de baixa frequência (10Hz, 150 µs, 2xdia, 40 minutos). A dor (escala visual analógica), a funcionalidade do ombro (Escore de Constant e Escala da UCLA) e os fatores relacionados à qualidade de vida (SF-36) foram avaliados. RESULTADOS: Nossos resultados mostram que o tratamento com a TENS reduziu significativamente a dor (p<0,05), melhorou a funcionalidade do ombro (tanto pelo Escore de Constant quanto Escala da UCLA; p<0,05) já na primeira semana e estes benefícios permaneceram até o final do tratamento (5 semanas) quando comparado com o período placebo. Os domínios capacidade funcional, dor, vitalidade e aspectos sociais apresentam uma melhora após 5 semanas de tratamento quando comparado com o período placebo (p<0,05). Foi verificado ainda que este efeito foi observado mesmo com a redução da quantidade de medicação analgésica. CONCLUSÃO: Nossos resultados mostram que a TENS de baixa frequência reduz a dor e melhora a funcionalidade do ombro e os fatores relacionados à qualidade de vida de pacientes com DRC. / INTRODUCTION: Chronic kidney disease (CKD) favors the development of numerous complications such as amyloidosis. In the shoulders, amyloid deposits promote inflammatory reactions and severe pain, which compromises the quality of life of patients with this disease. There are few therapeutic options for the treatment of this complication. OBJECTIVE: The objective of the present study was to evaluate the effect of transcutaneous electrical nerve stimulation (TENS) in the treatment of pain and in shoulder functional capacity, as well as factors related to the quality of life in patients with CKD. METHODS: Thirty patients were evaluated 5 times over a period of 6 weeks. At week 1, the equipment was programmed to not transmit the electrical current (placebo) and in the 5 subsequent weeks we used low frequency current (10Hz, 150 µs, twice a day, 40 minutes). Pain (visual analog scale), shoulder functional capacity (Constant score and UCLA Shoulder Rating Scale) and factors related to the quality of life (SF-36) were evaluated. RESULTS: Our results show that the treatment with TENS significantly reduced pain (p<0.05), improved shoulder functional capacity (using both Constant score and UCLA Shoulder Rating Scale; p<0.05) at week 1 and these benefits remained until the end of the treatment (5 weeks) when compared with the placebo period. The domains of functional capacity, pain, vitality and social functioning present improvement after 5 weeks of treatment when compared with the placebo period (p<0.05). It was also found that this effect was observed even after the administration of analgesics was reduced. CONCLUSION: Our results show that low frequency TENS reduces pain and improves shoulder functional capacity and factors related to the quality of life of patients with CKD.
128

Efeito da dor crônica no ombro no comportamento motor de uma tarefa de apontamento com o corpo inteiro / Effect of chronic shoulder pain on the motor behavior of a whole body pointing

Marcello Ferraz de Campos de Sousa 19 October 2018 (has links)
Em indivíduos saudáveis o desempenho motor e os parâmetros cinemáticos e espaçotemporais da tarefa de alcance já estão descritos na literatura. Até o momento nenhum estudo investigou a influência da dor crônica no ombro nessas variáveis durante a tarefa de apontamento com o corpo todo em diferentes demandas, e nem estabeleceram como é o comportamento motor. Por este motivo, o objetivo do presente estudo foi caracterizar o comportamento motor de uma tarefa de apontamento em indivíduos com dor no ombro e avaliar parâmetros de padrão de movimento, desempenho motor e equilíbrio. Trata-se de um estudo transversal realizado no Laboratório de Bioengenharia Elétrica da Escola Politécnica da USP. Participaram do estudo 20 sujeitos, sendo 11 no grupo controle (GC) e 9 no grupo com dor (GD). O experimento consistiu em realizar um alcance em três angulações distintas (menor, igual e maior que 90°) em duas velocidades (normal e rápida). Foram coletados dados de cinemática e plataforma de força. As principais medidas foram (1) índice de retidão (IR); (2) tempo de reação e movimento (3) deslocamentos angulares e lineares (4) COP e COM. Os resultados mostraram que o GD apresentou pior IR, maior tempo de reação e de movimento, os deslocamentos lineares e angulares foram mais estereotipados, os deslocamentos do COM e a velocidade de deslocamento do COP foram menores e as estratégias de equilíbrio foram menos utilizadas, gerando manutenção do controle em bloco. Desta forma, conclui-se que o comportamento motor é alterado no GD e as variáveis de padrão de movimento, desempenho motor e de equilíbrio foram piores na comparação com indivíduos saudáveis / In healthy subjects the motor performance and the kinematic parameters and spatiotemporal parameters of the task of reaching have already been described in the literature. Until now no study has investigated the influence of chronic shoulder pain on these variables during whole body pointing in different demands and did not establish how motor behavior works. For this reason, the aim of the present study was to characterize the motor behavior of a pointing task in individuals with shoulder pain and to evaluate patterns of movement pattern, motor performance and balance. This is a cross-sectional study conducted at the Bioengineering Laboratory of the Polytechnic School of USP. Twenty subjects participated in the study, being 11 in the control group (CG) and 9 in the pain group (PG). The experiment consisted in achieving a range in three distinct angles (smaller, equal and greater than 90 °) in two speeds (normal and fast). Kinematics and force platform data were collected. The main measures were (1) straightness index (RI); (2) reaction time and movement (3) angular and linear displacements (4) COP and COM. The results showed that the GD presented worse IR, longer reaction time and movement, linear and angular displacements were more stereotyped, the COM displacements and the COP displacement velocity were smaller and the equilibrium strategies were less used, generating maintenance of block control. However, we conclude that motor behavior is altered in GD and the variables of movement pattern, motor performance and balance were worse in comparison with healthy individuals
129

Investigação do controle sensório-motor e da relação funcional de torque de rotação do ombro em arremessadores com e sem sintomas de impacto

Zanca, Gisele Garcia 19 August 2010 (has links)
Made available in DSpace on 2016-06-02T20:19:14Z (GMT). No. of bitstreams: 1 3228.pdf: 1290499 bytes, checksum: b265c618eaa3f97d66f4b3ab4a0e214c (MD5) Previous issue date: 2010-08-19 / Universidade Federal de Minas Gerais / Repetitive throwing movement causes adaptations to athletes shoulders and predisposes them to the development of impingement symptoms. The objective of this study was to investigate if there are alterations in sensorimotor control and in the functional torque ratio of shoulder rotation in overhead athletes with impingement symptoms and to distinguish these from alterations due to sporting practice. To this end, three groups of subjects were evaluated: athletes with impingement symptoms, asymptomatic athletes and a control group of nonathletes. The participants were evaluated with a Biodex System 3 isokinetic dynamometer in a seated position with the shoulder at 90º of adduction and 90º of elbow flexion. Sensorimotor control was evaluated using an isometric torque steadiness evaluation. The isometric peak torque and submaximal torque steadiness at 35% peak torque were tested during medial rotation and lateral rotation of the shoulder. For each submaximal repetition, the standard deviation, coefficient of variation and time to stability were calculated. Only the standard deviation during medial rotation was greater in asymptomatic athletes than in control group. The isokinetic evaluation was carried out at the velocities 90°/s e 180°/s and 240°/ in concentric and eccentric modes. Peak torque-to-body weight and the functional torque ratios LREcc/MRCon and MREcc/LRCon were compared between groups. Asymptomatic athletes presented greater peak torque-to-body weight for concentric medial rotation at 180°/s and a lower LREcc/MRCon ratio at 90°/s and 180°/s than CG. The velocity 240°/s was excluded from the analyses because many participants were unable to reach the predetermined velocity in the eccentric tests, principally during lateral rotations. This difficulty was attributed to the low peak torque of lateral rotation that could be generated in this position. Overall, the results demonstrated that overhead sports training leads to adaptations in maximal torque and in the torque steadiness of medial rotation in healthy athletes, which may be related to throwing performance. Nevertheless, it is not possible to conclude that such alterations predispose these athletes to injury, since athletes with impingement symptoms group was not significantly different from the other groups in any of the evaluations. / O movimento repetitivo de arremesso gera adaptações no ombro de atletas, e os predispõe ao desenvolvimento de sintomas de impacto. O objetivo deste estudo foi investigar se há alterações no controle sensório-motor e na relação funcional de torque isocinético de rotação do ombro em atletas arremessadores com sintomas de impacto e diferenciar daquelas relacionadas a adaptações da prática esportiva. Sendo assim, foram avaliados três grupos de indivíduos: atletas com sintomas de impacto, atletas assintomáticos e um grupo controle de sujeitos não treinados. Os participantes foram avaliados no dinamômetro isocinético Biodex System 3, sentados, com o ombro posicionado a 90º de abdução e 90º de flexão do cotovelo. O controle sensório-motor foi avaliado por meio da flutuação do torque isométrico submáximo. O pico de torque isométrico e a flutuação do torque a 35% do pico de torque isométrico foram avaliados durante as rotações medial e lateral do ombro. Para cada repetição submáxima foram calculados o desvio-padrão, o coeficiente de variação e o tempo para atingir a estabilidade. Apenas o desvio-padrão de rotação medial foi maior no grupo de atletas assintomáticos comparado ao grupo controle. A avaliação isocinética foi realizada nas velocidades de 90°/s, 180°/s e 240°/s, nos modos concêntrico e excêntrico. O pico de torque/peso corporal e as relações funcionais de torque de rotação lateral excêntrico/rotação medial concêntrico (RLExc/RMCon) e rotação medial excêntrico/rotação lateral concêntrico (RMExc/RLCon) foram comparados entre os grupos. O grupo de atletas assintomáticos apresentou maior pico de torque/peso corporal de rotação medial concêntrica, a 180°/s, e menor relação RLExc/RMCon, a 90°/s e 180°/s, quando comparado ao controle. A velocidade de 240°/s foi excluída das análises, pois muitos participantes não conseguiram atingir a velocidade pré-determinada nos testes excêntricos, principalmente de rotação lateral. Essa dificuldade foi atribuída ao baixo pico de torque de rotação lateral capaz de ser gerado nessa posição. Em conjunto, os resultados demonstram que o treino de arremesso gera adaptações no torque máximo e na flutuação do torque submáximo de rotação medial em arremessadores saudáveis, possivelmente relacionados ao desempenho do arremesso. Entretanto, não é possível concluir se estas alterações predispõem esses atletas ao desenvolvimento de lesões, uma vez que o grupo de atletas com sintomas de impacto não se apresentou diferente dos outros grupos em nenhuma das situações avaliadas.
130

Cinemática escapular : confiabilidade e efeitos pré e pós uma manipulação torácica em sujeitos com e sem sintomas de impacto - um estudo controlado randomizado

Haik, Melina Nevoeiro 21 February 2013 (has links)
Made available in DSpace on 2016-06-02T20:19:21Z (GMT). No. of bitstreams: 1 5121.pdf: 13124971 bytes, checksum: 6e287fe7f29cdce25264d37ed5bc3045 (MD5) Previous issue date: 2013-02-21 / Financiadora de Estudos e Projetos / Background: There is a lack of studies that evaluated within day and between day reliabilities of 3-D scapular kinematics during elevation and lowering of the arm in different shoulder conditions, as well as studies about low-amplitude and high-velocity thoracic spine manipulation (TSM) effects on scapular kinematics in subjects with shoulder dysfunctions. Objective: To establish within day and between day reliability of scapular motion during elevation and lowering of the arm and at rest position and to evaluate the immediate effects of a TSM on pain and scapular kinematics during elevation and lowering of the arm, both in subjects with and without shoulder impingement syndrome (SIS). Methods: Kinematic data were collected using Flock of Birds® electromagnetic device. Subjects were divided in 2 groups: control and impingement. For reliability kinematic data were collected during elevation and lowering of the arm and at rest position on 2 different occasions separated by 3 to 5 days. Forty-nine subjects were tested for within day reliability. Forty-three subjects were reassessed for between day reliability. For kinematic evaluation pre- and ppost-manipulation, scapular kinematics was collected during elevation and lowering of the arm before and immediately after the intervention. Numeric pain rating scale was used to assess shoulder pain during arm movement at pre- and post- intervention. Fifty subjects (31.76 ± 10.91 years) with SIS and 47 subjects (25.76 ± 5.01 years) asymptomatic for shoulder dysfunctions were randomly assigned to one of the groups: manipulation or sham. Results: There was very good within day reliability for assessing scapular internal and upward rotations and tilt from both groups during elevation and lowering of the arm (ICC=0.92-0.99). In general, there was good between day reliability for assessing scapular motion during elevation and lowering of the arm from both groups (ICC=0.54-0.88). There was also good and very good between day reliability for assessing scapular rest position in both groups (ICC=0.66-0.95). Study 2: Subjects with SIS experienced reduced shoulder pain (from 3.29 to 2.45, p<0.01) during arm movement immediately after TSM. Subjects with and without SIS who received TSM and asymptomatic subjects who received sham intervention showed significant increase in scapular upward rotation at post-intervention. Increase in scapular anterior tilt at postmanipulation was also observed in asymptomatic subjects who received TSM. Conclusion: Flock of Birds® electromagnetic tracking system is a reliable device for measuring 3-D scapular motion during elevation and lowering of the arm and at rest position in subjects with and without impingement symptoms over time. TSM is associated with improved shoulder pain and scapular upward rotation in subjects with SIS. Although with questionable clinical relevance, TSM may not be immediately favorable to scapular tilt in asymptomatic subjects. / Além da escassez de evidências a respeito da confiabilidade entre repetições e dias da avaliação cinemática 3-D da escápula durante a elevação e descida do braço em diferentes condições do ombro, estudos sobre os efeitos da manipulação torácica de alta velocidade e baixa amplitude (MT) na cinemática escapular em sujeitos assintomáticos e portadores de disfunções no ombro também são bastante escassos. Objetivo: Determinar a confiabilidade entre repetições e entre dias das medidas do movimento 3-D da escápula durante a elevação e descida do braço e na posição de repouso e avaliar os efeitos imediatos de uma MT na dor e na cinemática da escápula durante a elevação e descida do braço, ambos em sujeitos assintomáticos e portadores da síndrome do impacto (SI). Métodos: Para a avaliação cinemática foi utilizado o dispositivo eletromagnético Flock of Birds®. Os sujeitos foram divididos em 2 grupos (controle e impacto). Os dados cinemáticos para a confiabilidade foram coletados durante a elevação e descida do braço e na posição de repouso em duas ocasiões diferentes separadas por 3 a 5 dias. Quarenta e nove sujeitos foram avaliados para a confiabilidade entre repetições e quarenta e três sujeitos foram avaliados para a confiabilidade entre dias. Para a avaliação pré e pós-manipulação os dados cinemáticos foram coletados durante a elevação e descida do braço antes e imediatamente após a intervenção. A escala numérica de dor mediu a dor durante o movimento do braço antes e após a intervenção. Cinquenta sujeitos (31,76 ± 10,91 anos) com SI e 47 sujeitos (25,76 ± 5,01 anos) assintomáticos para disfunções no ombro foram aleatoriamente designados a um dos seguintes grupos : manipulação ou sham. Resultados: A confiabilidade das medidas entre as repetições foi excelente para as rotações medial e superior e para a inclinação da escápula em ambos os grupos durante a elevação e a descida do braço (CCI=0,92-0,99). No geral, confiabilidade entre dias para avaliar os movimentos escapulares durante a elevação e a descida do braço para ambos os grupos foi boa (CCI=0,54-0,88). A confiabilidade entre dias também foi boa e excelente para as rotações escapulares durante a posição de repouso em ambos os grupos (ICC=0,66-0,95). Houve melhora significativa da dor nos sujeitos com SI (de 3,29 para 2,45, p<0,01) durante o movimento do braço imediatamente após a MT. Os sujeitos com e sem SI que receberam a MT e os sujeitos assintomáticos que receberam a intervenção sham apresentaram significativo aumento na rotação superior da escápula após a intervenção. O aumento na inclinação anterior após a manipulação também foi observado nos sujeitos assintomáticos que receberam a MT. Conclusão: O Flock of Birds® é um dispositivo eletromagnético confiável para medir ao longo do tempo o movimento 3-D da escápula durante a elevação e descida do braço e na posição de repouso em sujeitos assintomáticos e portadores de SI ao longo do tempo. A MT está associada com a melhora da dor e da rotação superior da escápula nos sujeitos com SI. E, apesar da questionável relevância clínica, a MT pode não ser imediatamente favorável para a inclinação escapular nos sujeitos assintomáticos.

Page generated in 0.034 seconds