• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 6
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 43
  • 43
  • 20
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Determinação do fator de pico de potência utilizando barras de controle, detectores ex-core e redes neurais

SOUZA, ROSE M.G. do P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:44Z (GMT). No. of bitstreams: 1 10895.pdf: 9491478 bytes, checksum: a17089904688d31b0c3d8e9056a263b2 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
32

Cost Evaluation of Building Space Heating; District Heating and Heat Pumps

Sultan, Sahira January 2017 (has links)
Climate change and energy efficiency has become a matter of concern in recent times; therefore, energy efficiency of buildings has drawn major attention. According to the European Commission, EU countries must improve energy efficiency of existing buildings by retrofitting and renovating the buildings. A case study of a renovated commercial building is considered in this degree project. A model of the building is developed in the IDA Indoor Climate and Energy (IDA ICE) software. The model is then augmented to include renovations in the building. Further, the model is simulated in IDA ICE before and after renovations to investigate the impact of renovations on energy consumption of the building for one year. The simulation results indicate peak demands of district heating that occur in the coldest days of the year. The peak demands of energy are expected to increase the district heating cost because they serve as a basis for new pricing model introduced by the energy providers. Hence, it is important from the customer point of view to reduce the peak loads for cost shavings. The project work also provides an insight into the alternative source of energy such as heat pumps to reduce the peak load demands of district heating.
33

Energy Efficiency through Thermal Energy Storage : Possibilities for the Swedish Building Stock

Heier, Johan January 2013 (has links)
The need for heating and cooling in buildings constitutes a considerable part of the total energy use in a country and reducing this need is of outmost importance in order to reach national and international goals for reducing energy use and emissions. One important way of reaching these goals is to increase the proportion of renewable energy used for heating and cooling of buildings. Perhaps the largest obstacle with this is the often occurring mismatch between the availability of renewable energy and the need for heating or cooling, hindering this energy to be used directly. This is one of the problems that can be solved by using thermal energy storage (TES) in order to save the heat or cold from when it is available to when it is needed. This thesis is focusing on the combination of TES techniques and buildings to achieve increased energy efficiency for heating and cooling. Various techniques used for TES as well as the combination of TES in buildings have been investigated and summarized through an extensive literature review. A survey of the Swedish building stock was also performed in order to define building types common in Sweden. Within the scope of this thesis, the survey resulted in the selection of three building types, two single family houses and one office building, out of which the two residential buildings were used in a simulation case study of passive TES with increased thermal mass (both sensible and latent). The second case study presented in the thesis is an evaluation of an existing seasonal borehole storage of solar heat for a residential community. In this case, real measurement data was used in the evaluation and in comparisons with earlier evaluations. The literature reviews showed that using TES opens up potential for reduced energy demand and reduced peak heating and cooling loads as well as possibilities for an increased share of renewable energy to cover the energy demand. By using passive storage through increased thermal mass of a building it is also possible to reduce variations in the indoor temperature and especially reduce excess temperatures during warm periods, which could result in avoiding active cooling in a building that would otherwise need it. The analysis of the combination of TES and building types confirmed that TES has a significant potential for increased energy efficiency in buildings but also highlighted the fact that there is still much research required before some of the technologies can become commercially available. In the simulation case study it was concluded that only a small reduction in heating demand is possible with increased thermal mass, but that the time with indoor temperatures above 24 °C can be reduced by up to 20%. The case study of the borehole storage system showed that although the storage system worked as planned, heat losses in the rest of the system as well as some problems with the system operation resulted in a lower solar fraction than projected. The work presented within this thesis has shown that TES is already used successfully for many building applications (e.g. domestic hot water stores and water tanks for storing solar heat) but that there still is much potential in further use of TES. There are, however, barriers such as a need for more research for some storage technologies as well as storage materials, especially phase change material storage and thermochemical storage. / Behovet av värme och kyla i byggnader utgör en betydande del av ett lands totala energianvändning och att reducera detta behov är av yttersta vikt för att nå nationella samt internationella mål för minskad energianvändning och minskade utsläpp. En viktig väg för att nå dessa mål är att öka andelen förnyelsebar energi för kylning och uppvärmning av byggnader. Det kanske största hindret med detta är det faktum att det ofta råder obalans mellan tillgången på förnyelsebar energi och behovet av värme och kyla, vilket gör att denna energi inte kan utnyttjas direkt. Detta är ett av problemen som kan lösas genom att använda termisk energilagring (TES) för att lagra värme eller kyla från när det finns tillgängligt till dess att det behövs. Denna avhandling fokuserar på kombinationen av TES och byggnader för att nå högre energieffektivitet för uppvärmning och kylning. Olika tekniker för energilagring, samt även kombinationen av TES och byggnader, har undersökts och sammanfattats genom en omfattande litteraturstudie. För att kunna identifiera byggnadstyper vanliga i Sverige gjordes även en kartläggning av det svenska byggnadsbeståndet. Inom ramen för denna avhandling resulterade kartläggningen i valet av tre typbyggnader, två småhus samt en kontorsbyggnad, utav vilka de två småhusen användes i en simuleringsfallstudie av passiv TES genom ökad termisk massa (både sensibel och latent). Den andra fallstudien som presenteras i denna avhandling är en utvärdering av ett existerande borrhålslager för säsongslagring av solvärme i ett bostadsområde. I detta fall användes verkliga mätdata i utvärderingen samt i jämförelser med tidigare utvärderingar. Litteraturstudien visade att användningen av TES öppnar upp möjligheter för minskat energibehov och minskade topplaster för värme och kyla samt även möjligheter till en ökad andel förnyelsebar energi för att täcka energibehovet. Genom att använda passiv lagring genom ökad termisk massa i byggnaden är det även möjligt att minska variationer i inomhustemperaturen och speciellt minska övertemperaturer under varma perioder; något som kan leda till att byggnader som normalt behöver aktiv kylning kan klara sig utan sådan. Analysen av kombinationen av TES och byggnadstyper bekräftade att TES har en betydande potential för ökad energieffektivitet i byggnader, men belyste även det faktum att det fortfarande krävs mycket forskning innan vissa av lagringsteknikerna kan bli kommersiellt tillgängliga. I simuleringsfallstudien drogs slutsatsen att en ökad termisk massa endast kan bidra till en liten minskning i värmebehovet, men att tiden med inomhustemperaturer över 24 °C kan minskas med upp till 20 %. Fallstudien av borrhålslagret visade att även om själva lagringssystemet fungerade som planerat så ledde värmeförluster i resten av systemet, samt vissa problem med driften av systemet, till en lägre solfraktion än beräknat. Arbetet inom denna avhandling har visat att TES redan används med framgång i många byggnadsapplikationer (t.ex. varmvattenberedare eller ackumulatortankar för lagring av solvärme) men att det fortfarande finns en stor potential i en utökad användning av TES. Det finns dock hinder såsom behovet av mer forskning för både vissa lagringstekniker samt lagringsmaterial, i synnerhet för lagring med fasändringsmaterial och termokemisk lagring.
34

Energy Efficiency through Thermal Energy Storage : Possibilities for the Swedish Building Stock

Heier, Johan January 2013 (has links)
The need for heating and cooling in buildings constitutes a considerable part of the total energy use in a country and reducing this need is of outmost importance in order to reach national and international goals for reducing energy use and emissions. One important way of reaching these goals is to increase the proportion of renewable energy used for heating and cooling of buildings. Perhaps the largest obstacle with this is the often occurring mismatch between the availability of renewable energy and the need for heating or cooling, hindering this energy to be used directly. This is one of the problems that can be solved by using thermal energy storage (TES) in order to save the heat or cold from when it is available to when it is needed. This thesis is focusing on the combination of TES techniques and buildings to achieve increased energy efficiency for heating and cooling. Various techniques used for TES as well as the combination of TES in buildings have been investigated and summarized through an extensive literature review. A survey of the Swedish building stock was also performed in order to define building types common in Sweden. Within the scope of this thesis, the survey resulted in the selection of three building types, two single family houses and one office building, out of which the two residential buildings were used in a simulation case study of passive TES with increased thermal mass (both sensible and latent). The second case study presented in the thesis is an evaluation of an existing seasonal borehole storage of solar heat for a residential community. In this case, real measurement data was used in the evaluation and in comparisons with earlier evaluations. The literature reviews showed that using TES opens up potential for reduced energy demand and reduced peak heating and cooling loads as well as possibilities for an increased share of renewable energy to cover the energy demand. By using passive storage through increased thermal mass of a building it is also possible to reduce variations in the indoor temperature and especially reduce excess temperatures during warm periods, which could result in avoiding active cooling in a building that would otherwise need it. The analysis of the combination of TES and building types confirmed that TES has a significant potential for increased energy efficiency in buildings but also highlighted the fact that there is still much research required before some of the technologies can become commercially available. In the simulation case study it was concluded that only a small reduction in heating demand is possible with increased thermal mass, but that the time with indoor temperatures above 24 °C can be reduced by up to 20%. The case study of the borehole storage system showed that although the storage system worked as planned, heat losses in the rest of the system as well as some problems with the system operation resulted in a lower solar fraction than projected. The work presented within this thesis has shown that TES is already used successfully for many building applications (e.g. domestic hot water stores and water tanks for storing solar heat) but that there still is much potential in further use of TES. There are, however, barriers such as a need for more research for some storage technologies as well as storage materials, especially phase change material storage and thermochemical storage. / Behovet av värme och kyla i byggnader utgör en betydande del av ett lands totala energianvändning och att reducera detta behov är av yttersta vikt för att nå nationella samt internationella mål för minskad energianvändning och minskade utsläpp. En viktig väg för att nå dessa mål är att öka andelen förnyelsebar energi för kylning och uppvärmning av byggnader. Det kanske största hindret med detta är det faktum att det ofta råder obalans mellan tillgången på förnyelsebar energi och behovet av värme och kyla, vilket gör att denna energi inte kan utnyttjas direkt. Detta är ett av problemen som kan lösas genom att använda termisk energilagring (TES) för att lagra värme eller kyla från när det finns tillgängligt till dess att det behövs. Denna avhandling fokuserar på kombinationen av TES och byggnader för att nå högre energieffektivitet för uppvärmning och kylning. Olika tekniker för energilagring, samt även kombinationen av TES och byggnader, har undersökts och sammanfattats genom en omfattande litteraturstudie. För att kunna identifiera byggnadstyper vanliga i Sverige gjordes även en kartläggning av det svenska byggnadsbeståndet. Inom ramen för denna avhandling resulterade kartläggningen i valet av tre typbyggnader, två småhus samt en kontorsbyggnad, utav vilka de två småhusen användes i en simuleringsfallstudie av passiv TES genom ökad termisk massa (både sensibel och latent). Den andra fallstudien som presenteras i denna avhandling är en utvärdering av ett existerande borrhålslager för säsongslagring av solvärme i ett bostadsområde. I detta fall användes verkliga mätdata i utvärderingen samt i jämförelser med tidigare utvärderingar. Litteraturstudien visade att användningen av TES öppnar upp möjligheter för minskat energibehov och minskade topplaster för värme och kyla samt även möjligheter till en ökad andel förnyelsebar energi för att täcka energibehovet. Genom att använda passiv lagring genom ökad termisk massa i byggnaden är det även möjligt att minska variationer i inomhustemperaturen och speciellt minska övertemperaturer under varma perioder; något som kan leda till att byggnader som normalt behöver aktiv kylning kan klara sig utan sådan. Analysen av kombinationen av TES och byggnadstyper bekräftade att TES har en betydande potential för ökad energieffektivitet i byggnader, men belyste även det faktum att det fortfarande krävs mycket forskning innan vissa av lagringsteknikerna kan bli kommersiellt tillgängliga. I simuleringsfallstudien drogs slutsatsen att en ökad termisk massa endast kan bidra till en liten minskning i värmebehovet, men att tiden med inomhustemperaturer över 24 °C kan minskas med upp till 20 %. Fallstudien av borrhålslagret visade att även om själva lagringssystemet fungerade som planerat så ledde värmeförluster i resten av systemet, samt vissa problem med driften av systemet, till en lägre solfraktion än beräknat. Arbetet inom denna avhandling har visat att TES redan används med framgång i många byggnadsapplikationer (t.ex. varmvattenberedare eller ackumulatortankar för lagring av solvärme) men att det fortfarande finns en stor potential i en utökad användning av TES. Det finns dock hinder såsom behovet av mer forskning för både vissa lagringstekniker samt lagringsmaterial, i synnerhet för lagring med fasändringsmaterial och termokemisk lagring. / <p>QC 20130225</p>
35

Techno-economic analysis of Battery Energy Storage Systems and Demand Side Management for peak load shaving in Swedish industries

Skog Nestorovic, Benjamin, Lindén, Douglas January 2020 (has links)
The Swedish electrical grid has historically been robust and reliable, but with increased electrification in numerous sectors, out-phasing of nuclear power and a high market diffusion of wind power, the system is now facing challenges. The rotational energy in the system is expected to decrease as a result of higher shares of intermittent energy sources, which can affect the stability of the grid frequency negatively. To manage increased frequency drops, the new Fast Frequency Reserve (FFR) market will be implemented by June 2020 in the Nordic power system. Simultaneously, it is expected that the demand of electricity will increase significantly in the transport and industry sectors in the coming years. Several DSOs already today indicate challenges with capacity and power security and have or will implement power tariffs as an economic incentive to prevent these problems. For energy intensive customers, such as industries, it will become important to reduce power peaks to avoid high grid fees. Several peak load shaving strategies can be utilized by industries to reduce their power peaks and thus the power tariff. The aim of this study is to economically analyze peak load shaving for Swedish industries. This is done using Li-Ion BESS and DSM, and to maximize the utilization of the BESS by including energy arbitrage and FFR market participation into the analysis. Firstly, a literature review is conducted within the topics of peak load shaving strategies, energy arbitrage and ancillary services. Secondly, data is gathered in collaboration with WSP Systems – Energy, the initiators of the project, to conduct case studies on two different industries. These cases are simulated in the modeling software SAM, for technical analysis, and then economically evaluated with NPV. Also, nine scenarios are created for the emerging FFR market concerning the number of activations per year and the compensation price per activation. The results from the case studies indicate that peak load shaving of 1 – 3 % with BESS provides a positive NPV for both case industries. However, higher percentages result in negative NPVs when no additional revenue streams are included. When considering energy arbitrage, it is concluded that the additional revenues are neglectable for both industries. Participating in the FFR market provides similar trends in the results as before. The exception is valid for scenarios with high numbers of FFR activations and compensation prices, where positive NPVs for all levels of peak load shaving can be concluded. The peak load shaving strategy DSM is implemented for one of the industries, where efficiency measures are concluded to have the most impact on the economic evaluation. If all efficiency measures would be implemented, the electricity consumption would be reduced by 17 %. Additionally, the power peaks would be reduced with 18 % and result in a significantly more positive NPV than peak load shaving using BESS. A sensitivity analysis concerning BESS capital cost and power tariff price concludes that the BESS price has a strong relation to the NPV, where a BESS price reduction of 60 % results in an NPV increase of at least 100 %. BESS prices have decreased the past years and are expected to keep decreasing in the future. Hence, investments in BESS can become more profitable and attractive in the coming years. Finally, for future research, it is recommended to combine the methodology from this study together with a load forecasting method. This combined methodology could then be practically applied to case specific industries with high peak loads. / Det svenska elnätet har historiskt sett varit robust och pålitligt, men i takt med ökad elektrifiering i flera sektorer, utfasning av kärnkraft samt ökad mängd installerad vindkraft ställs nu systemet inför nya utmaningar. Bland annat förväntas rotationsenergin i systemet minska som ett resultat av högre andelar intermittenta energikällor i systemet. För att hantera detta kommer den nya Fast Frequency Reserve (FFR) marknaden finnas tillgänglig från och med juni 2020. Samtidigt förväntas även efterfrågan på el inom transport- och industrisektorn öka markant de kommande åren. Redan idag är effektbrist ett problem i vissa regioner, vilket kan komma att förvärras. Många nätägare ska eller har redan infört effekttariffer för utnyttjande av deras elnät, vilket är ett ekonomiskt incitament för att hantera effektproblematiken där kunder med en mer flexibel elkonsumtion kommer gynnas. För större elförbrukare, som exempelvis industrier, kan det bli ekonomiskt betydelsefullt att sänka sina effekttoppar och därmed undvika höga nätavgifter. För att minska effekttoppar finns ett flertal så kallade peak load shaving-strategier, som kan utnyttjas av industrier för att minska kostnaderna för effekttariffen. Syftet med denna studie är att analysera peak load shaving för svenska industrier, med hjälp av ett Li-Ion batterilagringssystem och efterfrågeflexibilitet, samt maximera utnyttjandet av batteriet genom att inkludera energiarbitrage och deltagande i FFR-marknaden i analysen. Ett första steg i arbetet är att utföra en litteraturstudie för de berörda områdena. I ett andra steg insamlas data tillsammans med WSP, initiativtagaren av projektet, för att kunna göra en fallstudie på två industrier. För dessa fallstudier undersöks de tekniska förutsättningarna för att implementera peak load shaving-strategier genom modellering i simuleringsprogrammet SAM. Sedan utreds de ekonomiska förutsättningarna för fallstudierna, där NPV används som ekonomiskt nyckeltal. Dessutom skapas nio scenarion för den kommande FFR-marknaden för att uppskatta kostnader och inkomster. Resultatet av fallstudien visar att 1 – 3 % kapade effekttoppar med batterilagring ger ett positivt NPV för båda industrierna. Över 3 % blir resultatet negativt utan ytterligare inkomstströmmar inkluderade. Energiarbitrage konstateras att bidra med marginella positiva fördelar. Vid inkludering av FFR-marknaden i analysen erhålls liknande trender i resultaten, bortsett från scenarion med relativt högt antal avrop och pris. I dessa fall blir även 4 – 10 % kapade effekttoppar ekonomiskt attraktiva. För en av industrierna utvärderas efterfrågeflexibilitet, där effektivisering av elkrävande processer har störst inflytande på resultatet. Vid implementering av samtliga effektiviseringsåtgärder skulle elkonsumtionen minska med 17 %. Dessutom minskar effekttopparna med 18 %, vilket resulterar i ett signifikant mer positivt NPV, jämfört med användningen av batterilager. En känslighetsanalys gällande batteripris och effekttariffer, konstaterade att batteripriset har en stark påverkan på NPV. Vid en batteriprisminskning på 60 % ökar NPV med minst 100 %. Därmed kan batteriinvesteringar bli mer gynnsamma och attraktiva om batteripriser fortsätter att falla, vilket flera prognoser indikerar. Slutligen rekommenderas framtida studier att kombinera metodiken från detta arbete med en prognostiseringsmetod för elanvändning i industrier. Denna kombinerade metod kan sedan praktiskt tillämpas på fallspecifika industrier med höga effekttoppar.
36

Optimisation et gestion des risques pour la valorisation de la flexibilité énergétique : application aux systèmes d’eau potable / Optimization and risk management for energy flexibility development : application to drinking water systems

Mkireb, Chouaïb 03 July 2019 (has links)
Dans un contexte de croissance démographique dans lequel certaines ressources naturelles sont de plus en plus limitées, une gestion optimisée et conjointe des réseaux publics de l’eau et de l’électricité s’impose. L’ouverture progressive des marchés de l’électricité à la concurrence et les changements de réglementation dans plusieurs pays ont contribué au développement des mécanismes de la flexibilité de la demande, permettant d’impliquer directement les consommateurs dans la gestion de l’équilibre offre-demande du réseau électrique. Les systèmes d’eau potable, étant de grands consommateurs d’électricité, disposent d’une flexibilité grâce à la présence d’ouvrages de stockage d’eau (bâches et réservoirs) et de pompes à vitesse variable. Cette flexibilité, souvent exploitée uniquement à des fins de sécurisation des demandes en eau, peut être valorisée pour permettre une meilleure gestion de l’équilibre du réseau électrique. L’objectif de cette thèse est l’évaluation des valeurs économiques et écologiques relatives à l’intégration de la flexibilité des systèmes d’eau potable dans la gestion opérationnelle du système électrique français. Une étude de l’architecture des marchés de l’électricité en France est d’abord menée pour identifier les mécanismes de flexibilité de la demande les plus adaptés aux contraintes d’exploitation des systèmes d’eau. Des modèles mathématiques d’optimisation sont ensuite proposés et résolus à travers certaines heuristiques, en intégrant les incertitudes relatives aux consommations d’eau, aux prix des marchés ainsi qu’à la disponibilité des équipements de pompage. Les résultats numériques, discutés en se basant sur trois systèmes d’eau potable réels en France, intègrent les aspects économiques (en considérant les risques associés), opérationnels et écologiques. Des réductions importantes des coûts d’exploitation des systèmes d’eau sont estimées à travers la valorisation de l’énergie non consommée pendant les moments de pointe sur le marché spot de l’électricité. En parallèle, la considération des incertitudes permet de sécuriser l’opération des systèmes d’eau en temps réel, et de maîtriser les risques économiques relatifs à l’équilibrage du réseau électrique. De plus, des réductions importantes des émissions de CO2, estimées à environ 400 tonnes par jour en France, peuvent être réalisées en réduisant les volumes d’électricité issus des sources fossiles. / In a context of demographic growth in which natural resources are more and more limited, optimized management of water and power networks is required. Changes in electricity markets regulation in several countries have recently enabled effective integration of Demand Response mechanisms in power systems, making it possible to involve electricity consumers in the real-time balance of the power system. Through its flexible components (variable-speed pumps, tanks), drinking water systems, which are huge electricity consumers, are suitable candidates for energy-efficient Demand Response mechanisms. However, these systems are often managed independently of power system operation, for both economic and operational reasons. In this thesis, the objective is the evaluation of the economic and the ecological values related to the integration of drinking water systems flexibility into power system operation through french demand response mechanisms. An analysis of the architecture of french electricity markets is first conducted, allowing to target the most suitable demand response mechanisms considering water systems operating constraints. Some mathematical models to optimize water systems flexibility are then proposed and solved through original heuristics, integrating uncertainties about water demands, market prices and pumping stations availability. Numerical results, which are discussed using three real water systems in France, integrate the economic aspects inclunding risks, operational and ecological aspects. Significant reductions in water systems operating costs are estimated through the optimization of demand response power bids on the French spot power market during peak times. In parallel, uncertainties consideration secures the operation of water systems in real time, and makes it possible to manage economic risks related to the power grid balancing. In addition, significant savings in CO2 emissions, estimated to around 400 tons per day in France, can be achieved by reducing electricity production from fossil sources.
37

Three Essays on Energy Economics and Forecasting

Shin, Yoon Sung 2011 December 1900 (has links)
This dissertation contains three independent essays relating energy economics. The first essay investigates price asymmetry of diesel in South Korea by using the error correction model. Analyzing weekly market prices in the pass-through of crude oil, this model shows asymmetric price response does not exist at the upstream market but at the downstream market. Since time-variant residuals are found by the specified models for both weekly and daily retail prices at the downstream level, these models are implemented by a Generalized Autoregressive Conditional Heteroskedasticity (GARCH) process. The estimated results reveal that retail prices increase fast in the rise of crude oil prices but decrease slowly in the fall of those. Surprisingly, retail prices rarely respond to changes of crude oil prices for the first five days. Based on collusive behaviors of retailers, this price asymmetry in Korea diesel market is explained. The second essay aims to evaluate the new incentive system for biodiesel in South Korea, which keeps the blend mandate but abolishes tax credits for government revenues. To estimate changed welfare from the new policy, a multivariate stochastic simulation method is applied into time-series data for the last five years. From the simulation results, the new biodiesel policy will lead government revenues to increases with the abolishment of tax credit. However, increased prices of blended diesel will cause to decrease demands of both biodiesel and blended diesel, so consumer and producer surplus in the transport fuel market will decrease. In the third essay, the Regression - Seasonal Autoregressive Integrated Moving Average (REGSARIMA) model is employed to predict the impact of air temperature on daily peak load demand in Houston. Compared with ARIMA and Seasonal Model, a REGARIMA model provides the more accurate prediction for daily peak load demand for the short term. The estimated results reveal air temperature in the Houston areas causes an increase in electricity consumption for cooling but to save that for heating. Since the daily peak electricity consumption is significantly affected by hot air temperature, this study makes a conclusion that it is necessary to establish policies to reduce urban heat island phenomena in Houston.
38

New opportunities provided by the Swedish electricity meter reform

Wallin, Fredrik January 2010 (has links)
The reduction of the impact of energy consumption is a priority issue and a major challenge that concerns every country in the world. This is a complex task that needs to be tackled from several angles in the search for areas where optimizations and savings can be made. In Sweden an electricity meter reading reform was fully implemented by 1st July 2009, including 5.2 million customers, and this created new set of circumstances in the Swedish electricity market. The main purpose of this thesis work has been to investigate the possibilities of increasing the use of remote meter readings. Two research questions have been: “How can the electricity market benefit from remote collected meter readings?” and “Where do barriers appear when utilizing meter readings?”. The work started in 2000/2001 to study Internet based applications that visualize electricity consumption patterns. Over these years the daily internet users have increased from approximately 40 % to 73 % and new markets for web-based applications have evolved. These solutions can be important in the forthcoming years as energy portals that hold new energy services. Experiences from new installations indicate that at least interested customers do submit information concerning building and household properties through internet. Still, it is challenging to enable the majority of customers to take part in these new solutions. It may therefore be important to remind customers on a regular basis in order maintain the frequency using the application and to make it habitual. Further the introduction of demand-based pricing allows electricity distribution utilities to achieve a stronger correlation between peak loads in the distribution network area and their revenues.
39

Building Energy Efficiency Improvement and Thermal Comfort Diagnosis

Shi, Hongsen 18 June 2019 (has links)
No description available.
40

Charge into the Future Grid : Optimizing Batteries to Support the Future Low-Voltage Electrical Grid

Dushku, Mergim, Kokko Ekholm, Julius January 2019 (has links)
The increase in electric vehicles and photovoltaic power production may introduce problems to the low-voltage distribution grid. With a higher number of electric vehicles, their accumulated charging power might breach the lowest allowed voltage level of the grid. Photovoltaic-modules can on the other hand exceed the highest allowed voltage level, by producing high accumulated power when the solar irradiance is high. Normally, electric distribution companies in Sweden reinforce the existing grid with more resilient infrastructure, such as stronger and larger cables or transformer stations. This is however a costly and time-consuming solution, which could be solved by using alternative means such as already existing resources. This Master's Thesis investigates how smart charging of batteries can support the low-voltage electrical grid with the increase in electric vehicles and photovoltaic power production. To do this, an optimization tool has been developed in Matlab. An existing model of a low-voltage grid is combined with the developed tool, where controllable batteries and photovoltaic-modules can be placed at specific households in the grid. The controllable batteries belong to either electric vehicles or stationary battery systems, and are intended to support the grid by the means of either reducing peak load powers, voltage variations, or a trade-off between them. Furthermore, this thesis investigates the maximum electric vehicle capability for a specific low-voltage electrical grid in Sweden. From the results, it can be concluded that smart charging of batteries can reduce the peak loads as well as voltage variations. The reduction of voltage variations for the entire low-voltage grid is greatest during the summer, when photovoltaic production generally is at its highest. The results also show that a stationary battery system can reduce the voltage variations to a greater extent, compared to an electric vehicle. Also, the introduction of multiple controllable batteries allows further support of the low-voltage grid. Regarding the maximum electric vehicle capability, the results show that the placement of the vehicles and the charging power strongly affect the maximum number of electric vehicles the low-voltage grid can manage. / Ökningen av elbilar och elproduktion från solceller kan ge problem i lågspänningsnätet. Med ett ökat antal elbilar kan den sammanlagrade effekten vid laddning underskrida den minsta tillåtna spänningsnivån i nätet. Solpaneler kan däremot leda till att den högsta tillåtna spänningsnivån överskrids, genom att producera en hög sammanlagrad effekt när solstrålningen är som högst. Vanligtvis förstärker elnätsbolag i Sverige det befintliga nätet med motståndskraftigare infrastruktur, såsom kraftigare och större kablar eller transformatorstationer. Detta är dock en kostsam och tidskrävande lösning, som skulle kunna lösas med alternativa medel, till exempel redan existerande resurser. Detta examensarbete undersöker hur smart laddning av batterier kan ge stöd till lågspänningsnätet, med en ökning av elbilar samt solcellsproduktion. För att undersöka detta har ett optimeringsverktyg utvecklats i Matlab. En befintlig modell av ett lågspänningsnät har kombinerats med det utvecklade optimeringsverktyget, där styrbara batterier samt solcellsproduktion kan placeras vid specifika hushåll i elnätet. De styrbara batterierna är antingen elbilar eller stationära batterisystem, och är ämnade till att stödja lågspänningsnätet genom att antingen reducera effekttoppar, spänningsvariationer eller en kompromiss av båda. Vidare undersöker detta examensarbete det maximala antalet elbilar som ett specifikt lågspänningsnät i Sverige kan hantera. Resultaten visar att smart laddning av batterier kan reducera effekttoppar samt spänningsvariationer. Reduceringen av spänningsvariationerna för hela lågspänningsnätet visar sig vara högst under sommaren, vilket är då solcellsproduktionen generellt är som högst. Resultaten visar även att stationära batterisystem kan reducera spänningsvariationer ytterligare, jämfört med en elbil. Att introducera flera styrbara batterier tillåter ett ännu större stöd till lågspänningsnätet. Angående det maximala antalet av elbilar som ett lågspänningsnät kan hantera visade resultaten att placeringen av elbilarna samt laddningseffekten har en stor påverkan.

Page generated in 0.0953 seconds