• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 8
  • 8
  • 8
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

MÄTNING AV LUFTTÄTHET I FLERBOSTADSHUS : Gällande krav, praktiskt genomförda mätningar samt en tillämpbar metod

Sörensen, Ida January 2009 (has links)
Stor förvirring råder kring hur lufttätheten ska mätas i flerbostadshus. De metoder som finns och de resultat som erhålls vid täthetsprovning av småhus är inte alltid applicerbara på flerbostadshus även om mätenheterna är de samma. Detta föranleder problemställningen för detta examensarbete: Varför och hur kontrolleras lufttätheten i ett flerbostadshus på ett praktiskt tillämpbart sätt, som också gör det möjligt att jämföra resultat från olika objekt? Metoderna som används för att undersöka detta är litteraturstudier och samtal med erfarna personer, samt demonstration av en mätmetod i fullskala. En diskussion med initiativtagarna till detta examensarbete leder fram till en rekommenderad metod och en mall för hur detta ska utföras. Byggnadsskalets luft-, diffusions- och vindtätning har stor betydelse för en byggnads energianvändning, fuktsäkerhet, termiska komfort och hygien, luftkvalitet, ljudmiljö, spridning av brand samt spridning av luftföroreningar utifrån och in. Lufttätheten är en avgörande faktor både för konstruktionens beständighet och för en god innemiljö i moderna byggnader. Lufttäta hus är dessutom lönsamma i längden för de inblandade aktörerna. På lång sikt även för miljön. Studier som gjorts visar att en byggnads energiåtgång för uppvärmning minskar med nästan 30 % om lufttätheten (egentligen luftgenomsläppligheten) förbättras från 0,8 l/s·m2 till 0,4 l/s·m2. En så stor minskning av energianvändningen kunde inte åstadkommas med andra energiförbättringsåtgärder som undersöktes. I Boverkets Regelsamling för byggande, BBR 2008 har kravet på lufttäthet tagits bort till förmån för ett funktionskrav för energianvändningen, under vilken lufttätheten faller in. Regelsamlingens allmänna råd hänvisar till standarden, SS-EN 13829 för bestämning av luftläckage. De metoder som idag finns att tillgå för att mäta lufttätheten hos byggnader är spårgasmetoden, täthetsprovning med provisorisk vägg, det egna ventilationssystemet, med mottryck i angränsande utrymmen samt med tryckdörr. Den sistnämnda metoden provades på flerbostadshus i Umeå med goda resultat. Observera att resultatet för denna rapport är en mall för mätningsförfarandet och den rekommenderade metoden för att mäta lufttäthet inom NCC i Umeå. Den beskriver en praktiskt tillämpbar metod där resultatet går att jämföra mellan olika objekt. Även en intern mätstorhet som beskriver ytterväggens täthet är framtagen. Mätstorheten och standardens relevans diskuteras. Ändringen i BBR från specificerade krav till funktionskrav anses vara kunskapsdrivande. Det förfarande som beskrivs i resultatet har bedömts vara det mest optimala under rådande förhållanden med den standard som finns. En förändring av standarden skulle kunna leda till en bättre metod som ger mer informativt resultat. / There is a great perplexity about how air permeability should be measured in multiple-unit dwellings. The methods available and the obtained results for determination of air permeability in single-dwelling houses are not applicable for multiple-unit dwellings, even if the derived quantities are the same. This causes the problem for this report: Why and how should the air permeability be determined for a multiple-unit dwelling in a functional and applicable way, which also makes it possible to compare the obtained results from different dwelling units? The methods used to explore solutions are literature studies, conversation with professionals and a full-scale demonstration of one of the methods. A discussion with the initiators of this report leads to the recommended method and a model for how it should be performed. The air-, diffusion- and windtightness of the building envelope are of big importance to the building. The use of energy, moisture transfer, thermal comfort and hygiene, air quality, noise, spreading of fire and spreading of air pollutions are all affected by it. The air tightness is a crucial element for the durability of the building and to secure a good indoor environment. Air tight buildings are also cost-effective in the long run for the involved participants. They are also good for the environment. A study that have been made show that the energy-use for heating buildings will be reduced with almost 30 % if the air permeability improves from 0,8 l/s·m2 to 0,4 l/s·m2. Such a big reduction of the energy use could not be accomplished with any other energy improvement-move that was investigated in the study. The Swedish building regulations, Boverkets Regelsamling för byggande BBR, used to have a demand for the air tightness of buildings. It has been removed in favor of a demand of the function for the energy use, which also include the air tightness. The common advices in BBR refer to the standard, SS-EN 13829 for determination of air permeability. The methods available for determination of air permeability in buildings are the tracer-gas method, determination with a temporary wall, the ventilation system, with corresponding pressure in adjacent spaces and determination with a Blower Door. The last method was demonstrated in multiple-unit dwellings in Umeå, Sweden, with good results. Note that the result of this report is a methodology and how the method should be performed within buildings erected by NCC in Umeå. It describes a functional and applicable method where the results can be compared between different objects. An internal quantity which describes the air permeability of the external wall has been developed. A discussion of the relevance if the derived quantity and the standard has been made. The change in BBR to demands of the function for the energy use has been considered to be a driving force for knowledge. The procedure described in the results has been considered to be the optimum procedure for existing conditions with the standard available. A change in the standard would lead to a better method which would give more informative results.
12

Slöseri i produktionsflödet: Analys av en platsgjuten betongvägg / Waste in the production flow: Analysis of a cast in-situ concrete wall

Fransson, Mattias, Jamtlien, Mattias January 2018 (has links)
Höga byggkostnader och betydande bostadsbrist i Sverige visar att ett effektivare bostadsbyggande krävs. En reducering av slöseri i byggprocessen bidrar till en effektivisering av både tid och kostnad. För att öka förståelsen för vikten av effektivisering synliggör den här studien slöseri i produktionsflödet för en platsgjuten betongvägg i ett bostadsprojekt. Studien visar även var i produktionsflödet det finns förbättringsmöjligheter. Slöseriet synliggjordes genom en tidsstudie som visade på stor potential till förbättring i bostadsprojektets resursflöde, materialflöde och informationsflöde. Mycket tyder på att dessa brister i produktionsflödet beror på allt för kort byggtid, vilket leder till att en fullgod planering inte alltid utförs. / High construction costs and considerable housing shortages in Sweden show that a more efficient housing construction is required. A reduction of waste in the construction process contributes to the efficiency of both time and cost. In order to increase the understanding of the importance of efficiency, this study reveals waste in the production flow of a cast in-situ concrete wall in a housing project. The study also shows where in the production flow there are improvement opportunities. The waste was made visible through a time study which showed great potential for improvement in the housing project resource flow, material flow and information flow. There are many indications that these shortcomings in the production flow are due to a too short construction time, which means that a good planning is not always carried out.
13

Brandstation i Frihamnen / Fire station in housing development district in Stockholm harbour

Tillberg, Erika January 2012 (has links)
En brandstation ställer specifika krav på funktionalitet och flöden - som i det här examensarbetet har fått generera rumsligheter och arkitektoniska händelser. Brandbilarna står uppradade i ett stort och rymligt garage. Ljuset flödar in genom portarna och det stora glastaket. Om hundrafemtio år kanske det inryms en konsthall här istället - så som i Magasin 3 en bit bort.
14

Förbättring av bärighet vid brand : Utvärdering av befintlig betongstomme i hus 08 Falu lasarett

Lindholm, Erik, Malmqvist, Robin January 2021 (has links)
Purpose: this degree project will examine the possibilities of increasing the structural integrity in case of fire of a preexisting concrete building according to the rules in EKS 11, specifically for a hospital building. Furthermore, the degree project will provide solutions to increase the structural integrity in case of fire. Method: the study is based on a technical report provided by Kadesjös Ingenjörsbyrå AB where information about the hospital buildings technical aspects is presented. To examine current rules for fire-resistance rating of the hospital building, the regulations presented in BBR and EKS 11 were studied. Products had to fulfill the criteria of the European testing standards when they were evaluated as solutions that would increase the structural integrity of the building. The products were then evaluated according to the criteria presented in Eurocode 2 when dimensioning with tabulated data. An interview were held with Michael Försth professor in structural and fire engineering. Professor Försth were asked questions to evaluate potential methods and products that could increase the fire-resistance rating of the hospital building. Results: showed that proposed solutions are able to increase the structural integrity in case of fire of the hospital building to a degree where they were able to fulfill the requirements. Not all solutions were appliable on all building components of the hospital buildings. The difference in technical aspects of the solutions were presented. Conclusions: the identified solutions for increasing the structural integrity in case of fire are rock wool insulation, fire protection paint, additional concrete casting on columns and installation of sprinkler system. The solutions differ in technical aspects such as the space they take when implemented, weight increase when implemented, the amount they increase the structural integrity in case of fire when implemented and the method of implementing the solutions.

Page generated in 0.0502 seconds