• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1977
  • 27
  • 25
  • 25
  • 25
  • 14
  • 13
  • 12
  • 10
  • 6
  • 5
  • 4
  • 4
  • 1
  • Tagged with
  • 2028
  • 1276
  • 728
  • 391
  • 250
  • 178
  • 169
  • 166
  • 158
  • 148
  • 126
  • 119
  • 119
  • 113
  • 112
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Regulamentos tecnicos de apoio para atendimento a NR 13 / Support technical standards to attend NR 13

Vecchi, Rodrigo de 08 November 2009 (has links)
Orientador: Caio Glauco Sanchez / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T18:39:43Z (GMT). No. of bitstreams: 1 Vecchi_Rodrigode_M.pdf: 8478782 bytes, checksum: 86a22fd7ce3d6d0db538dbff0f6c1341 (MD5) Previous issue date: 2009 / Resumo: Procurou-se neste trabalho, reunir uma grande quantidade de normas técnicas de inspeção, de projeto e de ensaios não destrutivos a fim de serem sugeridos e principalmente fornecer dados e critérios necessários para a realização segura e apropriada dos exames e testes tidos como mandatórios ou alternativos na NR13. Para isto foi necessária uma pesquisa detalhada do acervo de normas técnicas existentes em nosso país e também em outros países, a fim de obter informações que pudessem ser confrontadas com casos específicos e reais, cujos dados foram coletados com profissionais qualificados e certificados. Três aspectos foram analisados: os requisitos da norma NR13, que é compulsória e tem abrangência geral, critérios específicos utilizados por normas de enfoque singular, ou seja, para uma única linha de equipamento, de teste ou de inspeção e a experiência prática que trouxe a realidade encontrada em muitos estabelecimentos através do resultado de inspeções realizadas para garantir a segurança na operação de vasos de pressão e caldeiras. Vale frisar que tais inspeções fazem parte de nosso acervo técnico pessoal e estão devidamente registradas no CREA através de mais de 600 ART's recolhidas em 8 diferentes estados brasileiros. Também foram apresentados alguns acidentes gerados, talvez, pela execução errônea de testes e inspeções, seguidos por sugestões que poderiam evitar a ocorrência dos mesmos. Os resultados desse trabalho são de grande importância nos futuros estudos e revisões normativas. / Abstract: It was intended to group a large amount of technical standards that treat about Boilers and Pressure Vessel design and inspections and also non destructive examinations in order to suggest and supply data and criteria to perform appropriate and safe inspections and examinations mentioned as mandatory or alternative at NR13. It was necessary an extensive research into Brazilian and foreign standards to collect information which could be confronted with real and specific cases described by qualified and certificated professionals. Three aspects have been analyzed: NR13 requirements which are mandatory and have only a global sight, criteria used in specific situations for unique kind of equipment, test or examination and practical experience that brought the reality of many companies through the result of inspections performed to guarantee a safe operation of pressure vessels and boilers. It is important to emphasize that these inspections belong to a personal technical performance and are registered at CREA through more than 600 ART's paid in 8 different Brazilian states. It was also presented some accidents probably caused by wrong execution of tests and inspections, followed by suggestions which could avoid them. The results obtained from this job are very important in future studies and revisions of normative standards. / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
202

"Determinação do Tempo de Resposta de Transdutores de Pressão Utilizando o Método Direto".

Sergio Ricardo Pereira Perillo 05 April 1994 (has links)
Neste trabalho são discutidos os diversos métodos para medida de tempo de resposta de transdutores de pressão ligados ao sistema de proteção de uma central nuclear, e apresentados os resultados obtidos através do método de medida direta. Para a realização das medidas foi utilizado um gerador hidráulico de rampa que permite gerar transientes de pressão dos tipos degrau e rampa gerando, simultaneamente, um sinal de teste para o transdutor analisado e para um transdutor de referência. O tempo de atraso entre a resposta do transdutor analisado e o transdutor de referência é chamado de tempo de atraso do transdutor, e indica quão rápido o transdutor analisado responde a uma variação. Foram analisados, neste trabalho, 11 (onze)transdutores de pressão, todos na faixa entre 25 e 400KPa, sendo 9 convencionais (de uso na indústria em geral) e 2 produzidos com classe nuclear (para uso em centrais nucleares)
203

Estudo de um secador atmosferico por contato indireto com agitação mecanica

Melo, Kiki Pinheiro de 30 July 2002 (has links)
Orientador : Marco Aurelio Cremasco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-02T20:23:50Z (GMT). No. of bitstreams: 1 Melo_KikiPinheirode_M.pdf: 2154978 bytes, checksum: f7a8694958832f2404e8e752ff8c4c92 (MD5) Previous issue date: 2002 / Resumo: No presente trabalho é estudado um secador atmosférico por contato com agitação mecânica, por intermédio da obtenção de curvas de cinética e de fluxo de secagem sob diversas condições operacionais de carga úmida de material, temperatura de aquecimento da superfície metálica, intensidade de agitação mecânica do material úmido e diâmetro da partícula. Os materiais de teste foram o pó de café (após a primeira extração) e esferas de vidro. Os resultados da cinética de secagem apresentaram um período constante de remoção de umidade e justificaram que o secador pode ser utilizado na secagem de materiais com características similares a esfera de vidro e ao pó de café. Já as curvas de fluxo de secagem experimentais foram comparadas com um modelo encontrado na literatura, que é baseado na teoria da penetração. Tais curvas ajustaram-se razoavelmente somente para as esferas de vidro enquanto que para o pó de café este modelo não se ajustou. Por meio de um planejamento experimental 23 somente para o pó de café, verificou-se que, para a variável de resposta umidade final do material, as variáveis independentes temperatura da placa de aquecimento e carga de material apresentaram significância estatística. Já para a variável temperatura final do material somente a temperatura da placa apresenta significância / Abstract: In the present work an atmosferic contact dryer agitated mechanically by scrapers was studied through its drying kinetics and drying flux curves under several operating parameters (material load, plate temperature, rotation speed and particle diameter). Coffee grounds after extraction and glass spheres were used as test materials. The results of the drying kinetics presented a constant period of moisture removal, justifying the fact that the dryer can be used for drying of particulate materials with similar properties. The drying experimental fluxes were also compared with a model found in the literature, which is based on the penetration theory. Such fits were adjusted reasonably only for the spheres of glasses while for coffee grounds the model didn't adjust. Using a 23 experimental planning only for the coffee grounds, was observed that the plate temperature and material load affected the final moisture content of the particle and while the plate temperature affected the final temperature of the particles / Mestrado / Engenharia de Processos / Mestre em Engenharia Química
204

Estudo do reflexo inibitorio retoanal em multiparas, na zona de alta pressão com cateter radial

Leal, Vilmar Moura 29 January 2003 (has links)
Orientador: Claudio Saddy Rodrigues Coy / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T16:26:48Z (GMT). No. of bitstreams: 1 Leal_VilmarMoura_M.pdf: 1606636 bytes, checksum: 7b12d0641f97608e38b55b8cc93da306 (MD5) Previous issue date: 2003 / Resumo: A fisiologia da evacuação e a fisiopatologia dos distúrbios evacuatórios ainda hoje não são bem compreendidas. A ocorrência destes distúrbios vem aumentando progressivamente, implica em limitações, compromete a qualidade de vida e tem custos significativos. A incontinência fecal acomete cerca de 2% da população, com predomínio em mulheres e que tenham tido partos normais. Com relação à constipação, em 30 a 50% dos casos, a causa é funcional. Os testes para o estudo da fisiologia anorretal têm sido bastante utilizados, especialmente a manometria. No entanto, algumas variáveis deste exame ainda apresentam dúvidas quanto sua interpretação. Dentre estas, destaca-se o Reflexo Inibitório Retoanal (RIRA), freqüentemente descrito como presente, ausente ou inconclusivo. Apenas recentemente vem sendo realizada uma abordagem mais pormenorizada deste. Sendo a pesquisa deste reflexo comumente realizada com cateter axial e considerando a assimetria anatômica do canal anal, seu estudo na zona de mais alta pressão (ZAP) com cateter radial poderia adicionar informações não disponíveis. Objetivo: estudar os parâmetros do reflexo inibitório retoanal em multíparas, com cateter radial. No período entre 2001 e 2002, foram estudadas 36 pacientes, com quatro a seis partos vaginais, com média de idade de 40,7 (30 a 50) anos, Grupo 1 e 10 pacientes, com um a três partos vaginais, com média de idade de 38,5 (31 a 50) anos, Grupo 2. Com relação à função evacuatória do Grupo 1, 63,9% das pacientes encontravam-se assintomáticas, 33,3% apresentavam como queixa constipação e 2,8% incontinência fecal. Dentre as pacientes do Grupo 2, 50% eram assintomáticas e as demais referiam constipação. Todas as pacientes são oriundas do Hospital Getúlio Vargas ¿ Teresina - PI - Universidade Federal do Piauí (UFPI). Foram analisados na ZAP a pressão anal média de repouso (PAM) e os seguintes valores por quadrante: pressão média de repouso pré-relaxamento (PREP), porcentagem de relaxamento (%RELAX), pressão no ponto de máximo relaxamento (PRELAX), tempo de relaxamento (TRELAX) e o tempo de recuperação (TREC). Não houve diferença significante entre as médias de idades dos pacientes dos Grupos 1 e 2 (p = 0,43), assim como entre as médias da pressão anal média de repouso (p = 0,053). Os valores das médias da PREP nos quadrantes apresentaram diferença com significância estatística, no Grupo 2. A comparação dos valores desta variável entre os Grupos 1 e 2 foi estatisticamente diferente nos quadrantes com exceção do anterior. Os valores das médias de PRELAX foram mais baixos e com significância estatística no Grupo 1, a comparação entre os grupos evidenciou diferença estatisticamente significante nos quadrantes 1 e 4. Não foram evidenciadas diferenças significativas entre os valores das médias de %RELAX no Grupo 1 ou Grupo 2, assim como entre os grupos. Também não ocorreu diferença significativa com relação aos valores dos tempos de relaxamento e de recuperação nos dois grupos, assim como a comparação destas variáveis entre os grupos nos diferentes quadrantes. Os dados obtidos nesta casuística permitem concluir que: 1- a PREP nos quadrantes, tende a uma simetria nas pacientes multíparas, provavelmente decorrente de comprometimento global da função esfincteriana; 2- o Reflexo Inibitório Retoanal(RIRA), contrariamente a PREP, pode ter os parâmetros que o compõe manifestados de maneira irregular nos diferentes quadrantes na ZAP, da mesma forma, em decorrência das alterações estruturais mais prováveis nas pacientes do Grupo 1; 3- a utilização do cateter radial no estudo do Reflexo Inibitório Retoanal (RIRA) pode fornecer dados não obtidos com o cateter axial / Abstract: Physiology of evacuation and physiopathology of evacuatories disturbs still today aren¿t well understood. The occurrence of this disturbs has been rising progressively, it implies in limitation, affects the quality of life and has significant costs. Fecal incontinence occurs at about 2% of population, more in women, especially in those who had vaginal delivery history. In relation to constipation, 30 ¿ 50% of the cases, the cause is functional. Physiologies tests have been used more and more frequently, among these tests the pioneer manometry has gain more attention. Therefore same variables of this test have still doubt about its interpretation. Among this doubts there is the inhibitory recto anal reflex (RIRA), frequently described as present, absent or inconclusive. Only recently a more detailed approach of this complex phenomena has been realized. Once the research of this reflex is commonly made with axial catheter, and considering that anatomy of the anal canal is not symmetric, the study of the RIRA in the high pressure zone (HPZ), with radial catheter could add more information that were not available. Aim: to study parameters of inhibitory recto anal reflex in multiparous, with radial catheter. In the period of 2001 to 2002, 36 patients with 4 to 6 vaginal delivery were studied, with average age 40,7 (30 ¿ 50) years old, belong to Group 1 and 10 patients with 0 to 3 vaginal delivery, with average age 38,5 (31 ¿ 50) years old, belong to Group 2. In relation to evacuation function in Group 1, 63,9% of the patients were asymptomatic, 33,3% had constipation and 2,8% had fecal incontinence. Among the patients of Group 2, 50% were asymptomatic and 50% were constipated. All patients were from Hospital Getúlio Vargas ¿ Teresina ¿ PI ¿ Federal University of Piauí ¿ UFPI. This study was approved by Ethical Committee of this university. In HPZ, anal resting pressure (ARP) and the follow values for quadrant: average of resting anal pressure before relaxation (PREP), percentage of relaxation (%RELAX), pressure at the point of maximum relaxation (PRELAX), relaxation time (TRELAX) and recovery time (TREC) were analyzed. There weren't significant difference between average age of the patients in the two groups (p = 0,43) as far as average of resting anal pressure (p = 0,053). The average values of PREP among quadrants had statistics significant differences in Group 2. The comparison of the values of this variable in two groups was statistically different in the quadrants except in the anterior. The values of PRELAX average were smaller and with statistics difference in Group 1, the comparison between groups shows statistics significant differences in quadrants 1 and 4. No significant differences were observed in the values of %RELAX in Group 1 or Group 2, as far as between the groups there were. Also no differences with relaxation and recovery time among quadrants in the groups as far as between groups. The data obtained in this study permit the following conclusion: 1- PREP among quadrants tend to a lack of symmetry in multiparous patient, probably because of global involvement of sphincter function; 2- RIRA in opposition of PREP, can have its parameters manifested of irregular way among quadrants of HPZ, the same way because of structural alterations more probably in patients of Group 1; 3- Use of radial catheter in study of RIRA can produce data that can not be obtained with axial catheter / Mestrado / Medicina Interna / Mestre em Ciências Médicas
205

Perda de carga e resistencia convectiva de dissipadores de calor considerando regiões de folga

Tomazeti, Cristina Autuori 23 August 2002 (has links)
Orientador: Carlos Alberto Carrasco Altemani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T17:14:43Z (GMT). No. of bitstreams: 1 Tomazeti_CristinaAutuori_M.pdf: 8198369 bytes, checksum: ecbd927b8c23b103de0afbc23581abc0 (MD5) Previous issue date: 2002 / Resumo: Um modelo compacto foi utilizado para prever a perda de carga e a resistência térmica convectiva de dissipadores de calor com aletas retas. Eles foram montados num duto retangular nas configurações sem folga, com folga lateral, de topo ou folga combinada. As predições do modelo compacto foram comparadas com medidas experimentais. Foi efetuada uma montagem experimental onde foram ensaiados três dissipadores com escoamento forçado de ar. A seção do duto retangular foi ajustada de forma a permitir as regiões de folga. Nas configurações com folga, parte do escoamento de ar escoa através dos canais formados pelas aletas e o restante sofre desvios para as regiões de folga. Em cada um desses ramos paralelos do escoamento, a perda de carga é a mesma e pode ser determinada através do método compacto utilizado. Este método foi baseado em correlações apropriadas para diversos mecanismos de perda de carga e gera um sistema de equações algébricas não lineares. Este sistema foi resolvido através de um método iterativo de solução, baseado no algoritmo SIMPLE. Os resultados obtidos com o modelo compacto foram comparados com os testes experimentais efetuados neste trabalho e com dados a literatura. Conhecendo o escoamento através dos canais aletados do dissipador, o modelo utilizado pode calcular a sua resistência convectiva com correlações de transferência de calor. Esse valor foi comparado com medidas experimentais efetuadas num dissipador de alumínio. Nestes testes, um aquecedor elétrico foi colado na face inferior da base do dissipador. O aquecedor era menor que a base e por isso a sua resistência térmica até a face convectiva era composta por uma parcela condutiva e outra de espalhamento. Com base em trabalhos da literatura, valores estimados desta resistência foram calculados e comparados com as medidas experimentais / Abstract: A compact model to predict the pressure drop and convective thermal resistance of finned heat sinks was used. Configurations without bypass area, with lateral bypass and combined bypass were considered. Comparisons between solutions obtained from compact model with those from experimental procedures, using three heat sinks under forced airflow, were performed. The duct transversal area was set in a way to observe the bypass regions. In configurations with bypass part of the air flows between the fins and the remaining air flow goes through the bypass regions. The pressure drop, which is constant in this case, can be determined via the compact model, based on correlations represented by a non-linear algebraic equations system solved by using SIMPLE algorithm. Experimental results presented in this work were compared with both compact model and the literature. Knowing the airflow through the finned of the heat sink, the presented model can calculate its convective resistance using correlations of heat transference. This value was compared with effected experimental measures in an aluminum heat sink. In those tests, an electric heater was glue in the inferior face of the base of the heat sink. The heater was shorter than the base, therefore its thermal resistance in the convective face was composed by two parcels, one due to conduction and the other related to spreading. Values of this thermal resistance based on literature, were calculated and compared with experimental data / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
206

Quantificação do classico processo de dissociação do virus do mosaico do tabaco (TMV) utilizando alta pressão hidrostatica

Santos, Jose Luis da Rocha 03 August 2018 (has links)
Orientador: Carlos Francisco Sampaio Bonafe / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-03T20:32:34Z (GMT). No. of bitstreams: 1 Santos_JoseLuisdaRocha_M.pdf: 1598289 bytes, checksum: 6d3896c0bb628510e88e64f7f6518770 (MD5) Previous issue date: 2004 / Mestrado
207

Medição Experimental E Predição Da Volatilidade De Flex Fuels

Silva, Fábio Adriano do Nascimento January 2005 (has links)
Made available in DSpace on 2014-06-12T18:07:04Z (GMT). No. of bitstreams: 2 arquivo7863_1.pdf: 836908 bytes, checksum: c35d1fd51137fbbcb28e98993cd96af5 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Compostos oxigenados são usados como aditivos para elevar a octanagem da gasolina automotiva. Esses compostos substituem outros que são ambientalmente mais nocivos, como é o caso do chumbo tetraetila. No Brasil, o oxigenado empregado é o etanol anidro, usado em teores que variam de 20% e 25%. Nos últimos anos foi iniciada a comercialização de veículos equipados com motores projetados para funcionar com misturas de gasolina C e álcool hidratado em qualquer proporção, o flex fuel. Com o objetivo de contribuir para melhor compreender as propriedades do flex fuel, neste trabalho foram medidos dados de pressão de vapor reid na temperatura de 37,8°C, curvas de destilação e massa específica das misturas de gasolina A e etanol anidro, gasolina C (20% e 25%) e etanol hidratado em vários teores (0 a 100%). O método utilizado para a medição da pressão de vapor da gasolina baseia-se nos métodos ASTM D 5191 e ASTM D 6378. Os resultados mostram que a presença do etanol e da água presente no álcool hidratado afetam fortemente a volatilidade do flex fuel em relação à gasolina A. Com uma abordagem do equilíbrio líquido-vapor, considerando o flex fuel como uma mistura pseudoternária gasolina A/etanol/água, os dados foram correlacionados pelo modelo NRTL. O desvio médio obtido foi inferior 0,30 ao desvio padrão de 1,5 kPa esperado nas medidas
208

Consumo alimentar, antropometria e lipídios circulantes de indivíduos ovolactovegetarianos e onívoros: um estudo comparativo

Fernandes Dourado, Keila 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T22:57:48Z (GMT). No. of bitstreams: 2 arquivo3068_1.pdf: 959071 bytes, checksum: 17c6478627525954222cb4bcec741318 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / A relação entre alimentação e doenças em grupos específicos, como o dos vegetarianos, tem requerido atenção dos estudiosos. Se no passado o interesse era o de se evidenciar os problemas causados pela deficiência de alguns nutrientes, hoje é evidente a tendencia em se estudar os possíveis benefícios para a saúde de uma alimentação estritamente ou parcialmente de origem vegetal, como no caso da dieta ovolactovegetariana. O presente estudo avaliou comparativamente as características sócioeconômicas, do estilo de vida, estado nutricional, risco cardiovascular através de indicadores antropométricos de obesidade central, consumo dietético, perfil lipídico e os níveis de pressão arterial de ovolactovegetarianos e onívoros de ambos os sexos. Para cada ovolactovegetariano foram selecionados dois onívoros de mesmo sexo e idade semelhante, visando ao pareamento das amostras nesses critérios e ao aumento do poder dos testes estatísticos. A amostra foi composta por 87 indivíduos, sendo 29 ovolactovegetarianos e 58 onívoros, com média geral de idade de 40 + 13 anos e 58,6% do sexo masculino. Dentro das características socioeconômicas, apenas o número de moradores por domicílio diferiu; os ovolactovegetarianos apresentaram um percentual maior na categoria de 5 ou mais pessoas. Quanto ao estilo de vida, os grupos diferiram apenas no hábito do tabagismo (p=0,00), onde os onívoros apresentaram maior proporção de fumantes. Não houve diferença significativa nos valores médios entre os grupos em nenhuma das variáveis antropométricas estudadas. Com relação à pressão arterial, apenas a pressão arterial sistólica (PAS) apresentou diferença significativa entre os grupos (p=0,02); os onívoros apresentaram maior valor. Os valores médios do colesterol total e LDL foram maiores (p=0,00) nos onívoros, já nos ovolactovegetarianos o nível sérico do TG foi maior (p= 0, 04). No entanto com relação ao HDL, não houve diferença significantiva. Dentre os parâmetros de consumo avaliados, apenas o consumo de energia foi semelhante entre os grupos. Os ovolactovegetarianos consumiram menos lipídios, ácidos graxos saturados, colesterol e proteínas e mais carboidratos e fibras que os onívoros. Apenas o grupo dos onívoros obteve correlação positiva entre o consumo de lipídios e o HDL (r = 0,391) e entre o consumo de ácidos graxos saturados e o HDL (r=0,447) . O presente estudo sugere que embora o perfil de consumo alimentar entre os ovolactovegetarianos seja considerado mais saudável, pelo menor consumo de gordura total, ácidos graxos saturados e colesterol, quando o estilo de vida e o consumo calórico total são semelhantes não há diferenças significativas no estado nutricional e nos indicadores antropométricos de risco cardiovascular. Uma dieta saudável não é decorrente apenas da retirada da carne e da gordura da alimentação. É fundamental evidenciar as vantagens da alimentação diversificada e rica em vegetais, fibras e nutrientes antioxidantes para um perfil lipídico e níveis de pressão arterial desejáveis, que são importantes fatores preventivos das doenças cardiovasculares
209

Separação de bandas fundamentais superpostos e interpretação de espectros no infravermelho de moleculas em fase gasosa

Ferreira, Marcia Miguel Castro, 1951- 14 July 2018 (has links)
Orientador : Adalberto B. M. S. Bassi / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-14T10:17:38Z (GMT). No. of bitstreams: 1 Ferreira_MarciaMiguelCastro_D.pdf: 4900383 bytes, checksum: 6831245c4ca70e75cc1de27f4e497df2 (MD5) Previous issue date: 1984 / Doutorado
210

Ação do enfluorano sobre a pressão intracraniana de cães hiperventilados

Ortenzi, Antonio Vanderlei, 1944- 15 July 2018 (has links)
Orientador : Alvaro Guilherme Bizerril / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-15T00:56:19Z (GMT). No. of bitstreams: 1 Ortenzi_AntonioVanderlei_D.pdf: 865374 bytes, checksum: eae63df5e76e4cd4173fcbfa0563ba09 (MD5) Previous issue date: 1976 / Resumo: Fez-se uma revisão da literatura referente aos efeitos dos anestesicos inalatôrios sobre a pressão intracraniana. Estes produzem vasodiatação cerebral e a aumentam. Contudo, os efeitos do enf1uorano ainda são discutidos e dai o objetivo do presente estudo: verificar a variação da pressão intracraniana de cães hiperventilados e submetidos à inalação do enfluorano concomitantemente ou 15 minutos apôs o inicio da hiperventilação. Em três grupos de dez cães anestesiados com pentobarbita1 sódico(30mg/Kg e.v.) foram determinados, durante ventilação espontânea o pH e as pressões parciais de gás carbônico e oxigênio no sangue arterial com o aparelho "IL Model 313 Automatic pH/8100d Gas Analyser"; a pressão intracraniana media( por punção da cisterna magna) e a pressão arterial media (por cateter na artéria femoral) o foram através de transdutores conectados com o polígrafo "SAN-EI 142-8". A seguir, receberam brometo de pancurônio(0,1 mg/kg e. v.) e foram hiperventilados com o Respirador Universal de Takaoka, uti1izando-se oxigênio a 100%. As determinações foram repetidas após 15, 30, 45 e 60 minutos. Decorridos 15 minutos de ventilação controlada mecânica, era iniciado o gotejamento de uma solução com pentobarbita1 sódico a 0,1% e cloreto sódio a 0,09%, na velocidade de 25 a 30 microgotas por minuto. O primeiro grupo serviu como controle para o método. Enfluorano, por via inalatória, na concentração de 1% em oxigênio obtida através do vaporizador Vaporane foi administrado ao segundo grupo, durante 30 minutos, iniciando-se após 15 minutos de hiperventilação. O terceiro grupo também recebeu este agente desta forma porém se iniciando simultaneamente com a hiperventilação. Houve diminuição estatisticamente significante da pressão arterial, atribuída à redução do debito cardíaco que se acentuou com a inalação do enfluorano. Embora tenha havido variações individuais da pressão intracraniana no sentido de aumento ou diminuição, estas não foram estatisticamente significantes e não puderam ser relacionadas com as modificações de pressão arterial, pressão parcial do gás carbônico e oxigênio e pH do sangue arterial. Concluiu-se que o enfluorano a 1% em oxigênio não altera, de maneira estatisticamente significante,a pressão intracraniana de cães hiperventilados 15 minutos antes do início da sua administração ou concomitantemente a este. / Abstract: Not informed. / Doutorado / Doutor em Ciências Médicas

Page generated in 0.0415 seconds