• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
721

Comparação entre o pericárdio bovino decelularizado e o pericárdio bovino convencional utilizado na confecção de biopróteses valvares cardíacas / Comparison between the decellularized bovine pericardium and the conventional bovine pericardium used in the manufacturing of cardiac bioprosthesis

Jean Newton Lima Costa 15 February 2005 (has links)
O pericárdio bovino tratado com glutaraldeído (GTA) e armazenado em formaldeído tem sido utilizado para confecção de biopróteses cardíacas ao longo das últimas décadas, já se tendo acumulado grande experiência com seu manuseio. Sabemos, no entanto, que o uso do GTA associadamente à presença de restos celulares existentes em meio às fibras de colágeno e elastina do pericárdio, são fatores indutores de resposta inflamatória e de enucleação de cristais de cálcio, o que compromete a durabilidade da bioprótese in vivo a longo prazo. No presente trabalho, tivemos como objetivo comparar a resistência mecânica do pericárdio decelularizado com o pericárdio convencional, assim como avaliar sua capacidade de induzir resposta inflamatória em modelo experimental com ratos. Para estudar as duas técnicas, dividimos os pericárdios em dois grupos: Grupo I - pericárdio submetido a tratamento convencional com GTA e Grupo II - pericárdio submetido a tratamento de decelularização previamente ao tratamento convencional com GTA. Após o processamento químico dos pericárdios, as amostras do Grupo II foram histologicamente avaliadas para confirmar a eficácia da decelularização. A seguir, analisamos a resistência mecânica nos dois grupos de pericárdio através dos testes de tração e de desnaturação térmica. Em nossa casuística, os dois grupos tiveram desempenho semelhante. A capacidade de induzir resposta inflamatória foi avaliada em estudo experimental em 50 ratos Wistar, machos, com 3 meses de idade, os quais foram submetidos a implante subcutâneo no abdome de fragmentos de pericárdio dos dois grupos. Igualmente, não evidenciamos diferença significativa. Nossa terceira etapa de avaliação consistiu em confeccionar 3 biopróteses (mitral n. 29) com o pericárdio decelularizado e que foram submetidas a avaliação hidrodinâmica juntamente com uma bioprótese convencional de teste. As biopróteses decelularizadas mostraram ter desempenho hidrodinâmico semelhante à prótese de teste e ao padrão de avaliação de próteses já conhecido da Braile Biomédica (S.J.Rio Preto-SP), todas atingindo a marca de 150 milhões de ciclos. A avaliação histológica do pericárdio das próteses ao fim da ciclagem mostrou padrão microscópico habitual, não tendo havido ruptura ou fragmentação anormal induzida por estresse mecânico. Temos como conclusão que a técnica de decelularização mantém a resistência física do pericárdio em comparação àquele convencionalmente preparado, não levando à fragmentação da matriz de colágeno e elastina e nem à perda de sua resistência mecânica tanto estática quanto dinâmica, além de não ter induzido resposta inflamatória diferente daquela habitualmente encontrada no pericárdio convencional / The bovine pericardium treated with glutaraldehyde (GTA) and stored in formaldehyde has been used in the manufacturing of cardiac bioprosthesis through the past decades, and a great knowledge has been acquired in this field. We know however that the use of the GTA and the presence of cell debris among the collagen and elastin fibers are triggers to induce inflammatory response and calcium deposition in the tissue, what compromises the long term durability of bioprosthesis in vivo. In this paper, our objective was to compare the decellularized and the conventional pericardium mechanical resistance and also its capability of inducing inflammatory response in an animal experimental model. In order to study these two techniques, we divided the pericardia into two groups: Group I- pericardia conventionally treated with GTA and Group II - pericardia previously decellularized and then conventionally treated with GTA. At first, after the pericardia chemical treatment, we performed histological analysis of Group II to certify the efficacy of the decellularization process. Afterwards, we analyzed the mechanical resistance in both groups using the stretching and shrinkage tests. In our samples, both groups had the same performance. The capacity of inducing inflammatory response was evaluated in an experimental study with 50 Wistar rats, male, 3 months old, which were operated to receive the pericardia patches of both groups underneath the dermal layer in the abdomen. We also did not find any difference between the groups. The third step of evaluation was to manufacture three decellularized bioprosthesis and one no decellularized one that were submitted to hydrodynamic tests. The decellularized and the test prosthesis showed the same performance and there was also no difference when compared with the known performance of the Braile Biomédica\'s (S.J.R. Preto-SP) bioprosthesis. They all reached 150 million cicles. The histological avaluation of the bioprosthesis showed the usual microscopic pattern, and there was no abnormal rupture or fragmentation caused by mechanical stress. We have therefore reached to the conclusion that the decellularization technique keeps the physical resistance of the pericardium when compared with the conventionally prepared. It does not cause damage or fragmentation of the collagen and elastin fibers and does not lead to loss of the mechanical resistance. And also, there was no difference in both groups regarding to inflammatory response studied in the animal model
722

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
723

Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas

Oliveira, José Luiz Góes de 18 July 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Passivity fit of an implant fixed partial denture (FPD) is one of major factor in treatment success. Among various factors that influence the passive fit of a prostheses is the kind of retained. Thus, the aim of this study was to evaluate, with the aid of linear strain gages (gauges), the tension generated around two implants after installation of a three-unit implant FPD. Five groups were analyzed (n = 5): 1. Control (only the abutments on implants); 2. Cement-retained prosthesis; 3. Screw-retained prosthesis made from plastic cylinders; 4. Screw-retained prosthesis made from Co-Cr machined collar abutments; 5. Hybrid prosthesis (cemented / screwed). For the investigation, homogeneous polyurethane experimental model with two parallel external hexagon implants was used. From this model, transfer impression and one master stone cast was made on which all frameworks were made accompanying a wax pattern. Aiming to measure the tensions, four strain gauges for each implant placed in the mesial, distal, buccal and lingual were glued on the top surface of the experimental block. The tests were performed by installing the samples on the implants according to the characteristics of each group. Five repetitions of readings for each specimen were performed. One-way ANOVA and Tukey test were applied to the average values (p <.05). The mean and standard deviation were obtained: Group 1 (48.71 με ± 0.29), Group 2 (60.03 με ± 22.65) and group 3 (254.15 με ± 46.23), Group 4 (215,42 με ± 30.48), Group 5 (70.05 με ± 13.78). These results showed that the cement-retained prostheses have the ability to produce less stress on the peri-implant area when compared to the screw-retained prosthesis (p≤.05). It was observed that the hybrid group had similar performance to the cement-retained prostheses and the control group (p>.05). Furthermore, the screw-retained prosthesis made from plastic cylinders showed similar performance to the Co-Cr machined collar abutments (p>.05). Finally, these results demonstrated that the generated tension to the peri-implant tissues is directly related to the type of retention. / A passividade de assentamento de uma prótese parcial fixa sobre implantes é um fator primordial para o sucesso no tratamento. Dentre vários fatores que interferem na adaptação passiva de uma prótese está o tipo de retenção utilizado. Desta forma, o objetivo deste estudo foi avaliar, com o auxílio de extensômetros elétricos lineares (strain gauges), a tensão gerada ao redor de dois implantes após assentamento de uma prótese parcial fixa implantossuportada de 3 elementos. Cinco grupos foram analisados (n=5): 1. Controle (apenas os munhões sobre os implantes); 2. Prótese Cimentada; 3. Prótese Parafusada confeccionada com cilindros plásticos; 4. Prótese Parafusada confeccionada com cilindros com base de Co-Cr; 5. Prótese híbrida (cimentada/parafusada). Para a investigação, foi utilizado um modelo experimental homogêneo a base de poliuretano com dois implantes hexágono externo paralelos entre si. Visando medir as tensões, foram colados na superfície superior do bloco experimental quatro strain gauges para cada implante, posicionados nas faces mesial, distal, vestibular e lingual. Os testes foram executados instalando os corpos de prova sobre os implantes de acordo com as características de cada grupo. Realizou-se 5 repetições de leituras para cada corpo de prova. Análise de variância e teste de Tukey foram aplicados sobre os valores médios obtidos, utilizando um nível de significância de 0,05. A média e desvio-padrão obtidos foram: Grupo 1 (48,71 με ± 0,29); Grupo 2 (60,03 με ± 22,65); Grupo 3 (254,15 με ± 46,23), Grupo 4 (215,42 με ± 30,48), Grupo 5 (70,05 με ± 13,78). Esses resultados mostraram que as próteses cimentadas geraram menos tensão à região periimplantar quando comparadas às próteses parafusadas (p=0,0004/p=0,0008). Observou-se que o grupo híbrido teve desempenho semelhante às próteses cimentadas e ao grupo controle (p=0,9540/p=0,3402). Além disso, as próteses parafusadas confeccionadas com cilindros plásticos apresentaram desempenho semelhante às confeccionadas com cilindros com a base de Co-Cr (p=0,1580). Por fim, estes resultados demonstraram que a tensão gerada aos tecidos perimplantares está diretamente relacionada ao tipo de retenção.
724

Estudo e desenvolvimento de tecnologias e técnicas para obtenção de prótese auricular com custo-efetividade por meio de modelagem 3d e manufatura aditiva

Artioli, Bárbara Olivetti January 2017 (has links)
Orientadora: Profª. Drª. Maria Elizete Kunkel / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia Biomédica, 2017. / A reconstrução auricular está presente desde 600 a.C. na forma de implante de retalhos de pele. Nos últimos anos, tem ocorrido cada vez mais pesquisas sobre o desenvolvimento de próteses que visam substituir um órgão do paciente sem a necessidade de realização de cirurgias. Novas tecnologias, como processos de aquisição da anatomia e manufatura aditiva, têm sido investigadas como alternativa para a produção de próteses auriculares com uma melhor relação custo/qualidade quando comparada com o processo manual. Nesta pesquisa foi desenvolvida uma metodologia para investigar o uso de quatro métodos de aquisição da estrutura externa do pavilhão auricular de uma voluntária (fotogrametria, escaneamento 3D, reconstrução 3D de imagens de tomografia computadorizada e modelagem 3D parametrizada) para a produção de moldes de prótese auricular por manufatura aditiva (técnica de deposição de material fundido). As próteses auriculares de silicone produzidas com esta metodologia apresentaram um excelente resultado estético com menos 3% de erro dimensional. Além disso, análises mecânicas (ensaios de resistência à tração e dureza) do silicone utilizado revelaram que as próteses produzidas apresentam ótima resistência mecânica que não é alterada pelo processo de pigmentação. Ensaios com pele suína mostraram que, dos quatro adesivos analisados, três apresentaram força de adesão satisfatória. Os resultados demonstram a viabilidade de uma metodologia acessível para a produção de próteses de orelhas utilizando softwares livres, tecnologias e suprimentos disponíveis no mercado brasileiro. / The auricular reconstruction is present since 600 BC through skin flaps implants. In the current years, prostheses have been developed to replace the patient's organ without the use of surgeries. Recently, new technologies, such as anatomical acquisition and additive manufacturing techniques are being applied in the production of auricular prostheses, aiming at obtaining a product with better cost/quality relation when compared to the manual manufacturing process. In this research, a methodology was developed to investigate the use of four methods to acquire the external structure of a volunteer's ear (photogrammetry, 3D scanning, 3D reconstruction of computed tomography images and parameterized 3D modeling) for the production of auricular prosthesis molds by additive manufacture (melt deposition technique). The silicone ear prosthesis produced with the presented methodology shows an excellent esthetic result with only 3% dimensional error. In addition, mechanical analysis (tensile strength and hardness tests) of the used silicone showed that the produced prostheses has excellent mechanical resistance that is not altered by the pigmentation process. Tests with swine skin showed that, of the four analyzed adhesives , three had satisfactory adhesion strength. The results demonstrate the feasibility of an accessible methodology for the production of ear prostheses using free softwares, technologies and supplies available in the Brazilian market.
725

Caracterização microestrutural e mecanica de ligas Ti-Cu para aplicações odontologicas / Microstructure and mechanical characterization of Ti-Cu alloys for dental applications

Andrade, Protasio Nery 28 July 2006 (has links)
Orientadores: Rubens Caram Junior, Adelino Aguiar Coelho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-08T17:54:45Z (GMT). No. of bitstreams: 1 Andrade_ProtasioNery_M.pdf: 9178937 bytes, checksum: f63ed0f47d8aa70b2d3a755e537fbe8f (MD5) Previous issue date: 2006 / Resumo: Em função de características como alta razão resistência/peso, ótima biocompatibilidade, elevada resistência à corrosão e módulo de elasticidade que pode ser controlado pela adição de elementos de liga, o uso de ligas de titânio pela indústria médica e odontológica está em franco crescimento. No presente estudo, ligas do sistema Ti-Cu com teores entre 5 e 15 % em peso de cobre foram fundidas através do processo de fundição por centrifugação em moldes de cobre. A alta taxa de resfriamento imposta pelo molde empregado levou à formação de microestruturas totalmente martensítica. Em seguida, tais microestruturas foram modificadas através tratamentos térmicos, levando a estruturas mais estáveis. A caracterização das amostras obtidas envolveu análise microestrutural através de microscopia óptica e eletrônica de varredura, difração de raios-X, ensaios mecânicos. Os resultados obtidos indicam que as altas taxas de resfriamento envolvidas promoveram a formação da estrutura metaestável _'. O aumento da concentração de cobre levou ao aumento na dureza promovida pela formação do intermetálico Ti2Cu. O Ti2Cu apresentou módulo de elasticidade menor do que a fase _. A fratura dos corpos de prova teve caráter dúctil e é intensamente afetada pela presença de porosidade / Abstract: Due to characteristics like high strength-to-weight ratio, high biocompatibility, enhanced corrosion resistance and the possibility of controlling elastic behavior by proper addition of alloying elements, the use of titanium by medical and dental industries is continuously growing. In this work, Ti-Cu alloys with a Cu content varying from 5% to 15 wt% were prepared by arc melting and cast in copper molds. The high cooling rate imposed by copper mold led to the formation of a completely martensitic structure. Following, the microstructure of these samples were modified by applying proper heat treatments, leading to more stable microstructures. The samples characterization includes microstructure analyzes through optical and scanning electron microscopy, X-ray diffraction method and mechanical tests. The results obtained suggest that application of high cooling rates resulted in the formation of a'metastable phase. As Cu content was increased, hardness also increased due to Ti2Cu intermetallic compound precipitation. The Ti2Cu compound was found to present lower elastic modulus than the modulus of a phase. Finally, it was found that the heat treated samples presented high ductility and their mechanical behavior is affected by porosities / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
726

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Fabiane Lopes Toledo 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.
727

Parametrização dimensional, por modelo de regressão, de próteses de mão para crianças, confeccionadas por manufatura aditiva / Dimensional parameterization, by regression model, of hand prostheses for children, made by additive manufacture

Maia, Bruno Alves 24 August 2016 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-02-16T16:21:52Z No. of bitstreams: 2 Dissertação - Bruno Alves Maia - 2016.pdf: 9862769 bytes, checksum: da6934df826a53e405a0f542815fc54d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2017-02-17T16:53:04Z (GMT) No. of bitstreams: 2 Dissertação - Bruno Alves Maia - 2016.pdf: 9862769 bytes, checksum: da6934df826a53e405a0f542815fc54d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-02-17T16:53:04Z (GMT). No. of bitstreams: 2 Dissertação - Bruno Alves Maia - 2016.pdf: 9862769 bytes, checksum: da6934df826a53e405a0f542815fc54d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-08-24 / The use of artificial limbs provides great improvements in the quality of life of people who were born with malformation or have lost their upper limbs. However, the value of conventional prostheses is not accessible to the majority of the population. In order to change this reality, began to emerge projects using additive manufacturing. The use of such technology allows the manufacture of more accessible and customized prostheses. However, the adequacy of project design is still a problem, due to the lack of data on the size of the upper limbs, especially on children and adolescents. Based on this need, this work seeks to find a way to parameterize the hand dimensions, thus helping in the better dimensioning of the prostheses. Thus, this work looks for a variable that presents satisfactory correlation with the dimensions of the upper limb. After finding such a relationship, a table and a parametric model were created that can estimate the length of the hand from the height. / A utilização de membros artificiais proporciona grandes melhorias na qualidade de vida de pessoas que nasceram com malformação ou perderam os membros superiores. No entanto, o valor das próteses convencionais não é acessível à maioria da população. Com o objetivo de modificar essa realidade, começaram a surgir projetos utilizando a manufatura aditiva. O emprego de tal tecnologia, permite a confecção de próteses mais acessíveis e customizadas. Porém, o dimensionamento adequado dos projetos ainda é um problema, devido à falta de dados relativos ao tamanho dos membros superiores, principalmente sobre crianças e adolescentes. Com base nessa necessidade, este trabalho busca encontrar uma forma de parametrizar as dimensões da mão, auxiliando assim no melhor dimensionamento das próteses. Sendo assim, este trabalho procura uma variável que apresenta correlação satisfatória com as dimensões do membro superior. Após encontrar tal relação, foram criados uma tabela e um modelo paramétrico que conseguem estimar o comprimento da mão a partir da estatura.
728

Avaliação clínica e radiográfica de implantes curtos: estudo retrospectivo no período de 7 anos / Clinical and radiographic evaluation of short implants: retrospective study for a period of 7 years

Karen Vaz Ayub 23 February 2018 (has links)
Áreas edêntulas com severa reabsorção óssea têm sido reabilitadas com próteses fixas instaladas sobre implantes curtos, evitando que os pacientes sejam submetidos a cirurgias de reconstrução óssea. Este estudo retrospectivo descreve o comportamento de implantes curtos avaliados em um período de 7 anos. A amostra foi composta por 70 pacientes, de ambos os gêneros, que receberam 136 implantes, de 6 ou 8mm de comprimento (Straumann® bone level e tissue level standard plus) sobre os quais foram instaladas próteses unitárias e múltiplas, cimentadas e parafusadas. Foram realizadas avaliações clínicas e radiográficas mensurando a estabilidade do implante por frequência de ressonância, perda óssea marginal por meio de radiografias panorâmicas, índices de placa e de sangramento marginal, taxas de sobrevivência do implante e da prótese. Dois implantes instalados na mandíbula foram perdidos, resultando em uma taxa de sobrevivência de 98,3%. A taxa de sobrevivência das próteses foi de 100%; a média de perda óssea foi de - 0,28mm; a estabilidade média dos implantes foi de 76,515 ISQ; as médias dos índices de placa e de sangramento foram de 32,83% e 33,21%, respectivamente. A estabilidade do implante foi maior na mandíbula que na maxila (p = 0,006). Os resultados obtidos nesta pesquisa, possibilitam afirmar que os implantes curtos podem ser utilizados com segurança dentro de suas indicações específicas. / Edentulous areas with severe bone resorption have been rehabilitated with fixed prostheses installed on short implants, avoiding surgeries of bone reconstruction. This retrospective study describes the behavior of short implants evaluated during 7 years. The sample consisted of 70 patients, of both genders, who received 136 implants, 6 or 8mm in length (Straumann® bone level and tissue level standard plus) on which single and multiple, cemented and screwed prostheses were installed. Clinical and radiographic evaluations were performed by measuring implant stability by resonance frequency, marginal bone loss by panoramic radiographs, plaque and marginal bleeding rates, the implant and prostheses survival rates. Two implants installed in mandible were lost, resulting in a survival rate of 98,3%. The prostheses survival rate was 100%; mean bone loss was -0,28mm; mean implants stability was 76,52 ISQ; mean plaque and bleeding indexes were 32,83% and 33,21%, respectively. The implant stability was higher in the mandible than in the maxilla (p = 0.006). The results obtained in this research make it possible to state that short implants can be used safely within their specific indications.
729

Contribuição ao projeto de implantes personalizados através de sistemas CAD e prototipagem rápida / Contribution to the design of customised implants by using CAD systems and rapid prototyping

Paulo César de Freitas Ramos 01 June 2007 (has links)
Nos últimos anos, as tecnologias de prototipagem rápida vem sendo amplamente utilizadas em aplicações na área de saúde, como ferramentas de auxílio na simulação e planejamento cirúrgico, bem como no projeto de implantes personalizados. Este trabalho fornece uma contribuição ao projeto destes implantes nas áreas de cranioplastia e buco-maxila. Baseado em sistemas CAD e nas tecnologias de prototipagem rápida são aplicadas diferentes alternativas para a geração adequada dos modelos médicos, ou biomodelos. Para aplicações em cranioplastias é proposto e implementado algoritmo para ajuste das bordas, permitindo dessa forma o correto ajuste do implante. Os resultados obtidos são aplicados diretamente em estudos de casos reais conduzindo a excelentes resultados e validando o procedimento proposto. / In the last years, the technologies of rapid prototyping have been widely used in medical applications, as supporting tools in the simulation and surgical planning, as well as in the design of customized implants. This work gives a contribution to the design of these implants in the cranioplasty and buco-maxila areas. Based on CAD systems and in the technologies of rapid prototyping, different alternatives are tested for the design of these modes, generically called as biomodels. For cranioplasty applications an algorithm is proposed and implemented for borders adjustment. The obtained results are directly applied in real case studies yielding to excellent results and validating the proposed procedure.
730

Avaliação da posição do modelo auricular virtual gerado por imagem captada com escâner a laser e desenvolvimento de dispositivo posicionador 3D / Evaluation of the position of the virtual auricular model generated by image captured by laser scanning and development of 3D positioner device

Priscila Galzo Marafon 13 March 2013 (has links)
Este trabalho fundamenta a aquisição de modelo digital auricular por meio do escâner de superfície e avalia o posicionamento tridimensional do modelo auricular digital, espelhado segundo medidas antropométricas faciais, com e sem referência anatômica do canal auditivo externo, bem como desenvolve um dispositivo posicionador tridimensional para prótese auricular. Os dados de dez indivíduos voluntários, adultos maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região craniofacial e de ambos os gêneros foram submetidos ao Teste dos Postos Sinalizados de Wilcoxon (p0,05) e a medida angular C6 foi avaliada de forma porcentual. Os resultados demonstram que ocorre assimetria nas medidas lineares da posição dos modelos auriculares direitos e esquerdos espelhados nos respectivos lados contralaterais da face sem a referência do conduto auditivo externo, sendo duas vezes mais frequente no espelhamento do modelo auricular esquerdo no lado direito da face. Observa-se menor assimetria dos modelos auriculares direitos espelhados no lado esquerdo da face e simetria na posição dos modelos esquerdos espelhados no lado direito da face, com a referência do conduto auditivo externo. A medida angular C6 apresenta menor assimetria na posição dos modelos auriculares direitos do que nos esquerdos, espelhados nos respectivos lados contralaterais da face, com e sem a referência do conduto auditivo externo. Conclui-se que a utilização do conduto auditivo externo como referência anatômica proporciona melhor simetria linear e angular da posição dos modelos auriculares virtuais direitos e esquerdos, espelhados nos respectivos lados contralaterais da face. O dispositivo posicionador projetado possibilita o ajuste das assimetrias detectadas no espelhamento de modelos auriculares, promovendo a compensação das discrepâncias evidenciadas durante o planejamento virtual para posicionamento do modelo auricular. / This study substantiates the acquisition of auricular digital model, by means of surface scanner, and assesses the placement of three-dimensional auricular digital models, mirrored according to facial anthropometric measurements, with and without anatomical reference of the external auditory canal, as well as developing a prosthetic device for three-dimensional positioning of the mirrored auricular model. The digital data of ten volunteers, adults over 25 years old, not suffering from congenital or acquired lesions in the craniofacial region and of both genders underwent Wilcoxon Ranking Test (p0.05) and angular measurement C6 was assessed as percentage. The results show that occurs asymmetry regarding the linear measurements in the positioning of the right and left ear models when mirrored in their contra lateral side of the face without reference of the external auditory canal, being twice as common in mirroring the left auricular model on the right side of the face. It is observed less asymmetry in the right auricular models mirrored on the left side of the face and symmetry in the positioning of the left models mirrored on the right side of the face, with the reference of the external auditory canal. The angular measurement C6 shows less asymmetry in the positioning of the models right auricular model than in those of the left, mirrored in their contra lateral side of the face, with or without reference to the external auditory canal. The use of the external auditory canal as anatomical reference provides better linear and angular symmetry in positioning the virtual auricular right and left models, mirrored in their contra lateral side of the face The three-dimensional positioner device designed enables the adjustment of the asymmetries found in mirroring the digital auricular models, providing compensation for discrepancies evidenced during the virtual positioning of the auricular model.

Page generated in 0.0779 seconds