• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
711

Influência da inclinação das cúspides, tipo de retenção e envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas sobre implantes /

Rocha, Cibele Oliveira de Melo. January 2015 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Francisco de Assis Mollo Junior / Banca: Ricardo Faria Ribeiro / Resumo: O objetivo do estudo foi avaliar a influência da inclinação das cúspides, do tipo de retenção e do envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas implanto-suportadas. Para o ensaio estático utilizou-se seis grupos (n=10): coroas cimentadas com cúspide de inclinação padrão (CIP) de 33º ou cúspides de inclinação reduzida (CIR) de 20°, parafusadas com o orifício de acesso ao parafuso (OAP) não-restaurado com CIP ou CIR e parafusadas com OAP restaurado com CIP ou CIR. Para o efeito do envelhecimento, 4 grupos foram utilizados (n=20): cimentadas com CIP ou CIR; e parafusadas com OAP não-restaurado com CIP ou CIR, em que 50 % das amostras de cada grupo foram cicladas mecanicamente previamente ao ensaio estático. Coroas de um segundo molar inferior foram confeccionadas sobre análogos de implante hexágono externo 5.0 (Biomet 3i, West Palm Beach, FL). O ensaio estático foi realizado aplicando-se força até a fratura da porcelana e para o efeito do envelhecimento, a ciclagem foi realizada (1 x 106; 125 N; 10Hz) antes do ensaio de resistência máxima à fratura. Após análise estatística observou-se que as médias de resistência à fratura apresentaram efeito significativo para Forma de Retenção (FR) e Inclinação de cúspide (IC) (p<0,01). Para FR apenas as coroas parafusadas não apresentaram diferenças estatísticas entre si (p>0,05), porém ambas apresentaram valores estatisticamente menores do que as cimentadas. Para IC, CIP apresentaram menores valores de resistência à fratura. Após o envelhecimento mecânico foi observado efeito significativo somente para os fatores isolados Forma de Retenção e Inclinação de cúspide (p<0,01), com melhores resultados para coroas cimentadas e CIR, respectivamente. O fator Envelhecimento Mecânico (p=0,659) não apresentou efeito significativo. Diante dos resultados, conclui-se que isoladamente... (Resumo completo, clicar acesso eletrônica abaixo) / Abstract: The aim of this study was evaluate the influence of cusp inclination, type of retention and mechanical aging on fracture strength of implant-supported metal-ceramic (MC) single crowns. To static test, six groups were used (n=10): cemented crowns with 33° standard cusp inclination (SCI) or with 20° reduced cusp inclination (RCI), screwed crowns with screw access hole (SAH) not restored with SCI or RCI and screwed crowns with SAH restored with SCI or RCI. To test aging effect, 4 groups were used (n=20): cemented with SCI or RCI; and screw-retained with SAH not restored with SCI or RCI, in which 50% of specimens of each group were submitted to mechanical aging previously to static test. Crowns of a lower second molar were made on the analog implant external hexagon 5.0 (Biomet 3i, West Palm Beach, FL). The cycling (1.106; 125N; 10Hz) will be performed before the fracture resistance test. The static test was performed in a universal testing machine EMIC DL2000, with load application until porcelain failure. After statistical analysis it was observed that the mean fracture resistance of porcelain showed significant effect (p<0.01), to type of retention (TR) and cusp inclination (CI), respectively. To TR, screwed crowns did not show statistical differences (p>0.05), however, both two showed statistically lower values than cemented. To CI, crowns with SCI showed lower values of fracture resistance. After mechanical aging, TR and CI showed significant effect (p<0.01), with better results to cemented crowns and RCI, respectively. The factor mechanical aging did not show significant effect (p=0.659). According to these results, it was concluded that alone, type of retention and the cusp inclination showed influence on fracture resistance of MC crowns, being cemented crowns and reduced cusps mechanically more resistant against a static and cyclic load. The mechanical aging had no significant... (Complete abstract electronic access below) / Mestre
712

Implementação de uma prótese ativa para membro superior de baixo custo /

Xavier, Ricardo Taoni January 2016 (has links)
Orientador: Aparecido Augusto de Carvalho / Resumo: This paper describes the implementation a low cost hand prosthesis, a mechanism constituted by sixteen degrees of freedom, five articulated fingers individually, driven by mechanical tendons. Its structure was made in a 3D printer. For the man-machine interfacing, a shield was developed which performs the acquisition of electromyographic signals, with two channels, SD card storage and an electronic system able to generate a database of movements made by the human hand. The Arduino platform was used for processing and programming. The system contains an app with a programmable drive and insertion movements protocol, providing independence to the user. Tests were conducted in which the implemented system performed movements, after storing various functional hand movements. This was possible due to the development of an algorithm capable of recognizing, quantifying and storing the signals produced by muscle contractions. The implemented active prosthesis worked well for patients with congenital deformity and amputee. The total value of the mechanical and electronic components required to implement the active prosthesis and the use of free hardware and software contribute to the low cost of the device. / Mestre
713

Avaliação clínica e radiográfica dos tecidos peri-implantares de implantes osseointegrados que receberam carregamento imediato /

Lemo, Vagner Samy. January 2004 (has links)
Resumo: Um estudo clínico e radiográfico foi realizado para analisar o resultado do tratamento com implantes unitários e unidos (prótese protocolo), instalados e imediatamente carregados. O estudo inclui 10 pacientes que receberam 10 implantes e próteses provisórias unitárias e 5 pacientes que receberam 25 implantes, 5 implantes cada paciente entre os foramens mentoniano, estes foram unidos e receberam uma prótese tipo protocolo. Todas as próteses foram instaladas imediatamente após a cirurgia. Em um intervalo de 6 e 12 meses todos os pacientes foram radiografados e avaliados clinicamente. Não foram registradas perdas no grupo de implantes unitários e o grupo de implantes que recebeu prótese protocolo perdeu 2 implantes. Não houve alterações nos parâmetros periodontais (clínicos e radiográficos) entre os períodos de 6 e 12 meses, e as diferenças encontradas entre os implantes unitários e unidos, parecem estar mais relacionados ao local de inserção (maxila - mandíbula). Podemos concluir que a carga imediata é um procedimento previsível tanto para implantes unitários como em implantes unidos. / Abstract: The study includes 10 patient that received 10 implants and unitary temporary prostheses and 5 patient that received 25 implants, 5 implants each patient one in the area previous of jawbone, these were united and they received a prosthesis type protocol. All of the prostheses were installed immediately after the surgery. In an interval of 6 and 12 months all the patients were x-rayed and evaluated clinically. Losses were not registered in the group of unitary implants and the group of implants that it received prosthesis protocol lost 2 implants. There were not alterations in the periodontal parameters (clinical and radiographic) among the periods of 6 and 12 months, and the differences found among the unitary and united implants, they seem to be more related to the insert place (jawbone - jaw). We can conclude that the immediate load is a previsible procedure so much for unitary implants as in united implants. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Roberto Henrique Barbeiro / Banca: Wilson Trevisan Junior / Mestre
714

Influência da altura da coroa em implantes osseointegrados : estudo pelo método dos elementos finitos tridimensionais /

Moraes, Sandra Lúcia Dantas de. January 2011 (has links)
Resumo: Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração ... (Resumo completo, clicar acesso eletrônco abaixo) / Abstract: The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Jorge Vicente Lopes da Silva / Banca: Fellipo Ramos Verri / Banca: Regina Tamaki / Banca: Estevão Tomomitsu Kimpara / Banca: Cátia Maria Fonseca Guerra / Doutor
715

Avaliação da resistência ao cisalhamento de sistemas para reparo em metalocerâmicas /

Santos, Juliana Gomes dos. January 2004 (has links)
Orientador: Renata Garcia Fonseca / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: O reparo em próteses metalocerâmicas é um procedimento útil em determinadas situações clínicas. Recentemente surgiram no mercado alguns materiais designados para tal finalidade que, segundo seus fabricantes, são promissores. Neste trabalho foi avaliada a resistência ao cisalhamento de determinados sistemas de reparo para metalocerâmicas. Foram confeccionadas amostras cilíndricas em liga de NiCr (Vera Bond II) e em porcelana feldspática (Noritake). Após inclusão destas em anel de PVC, suas superfícies foram lixadas (320) e, com auxílio de matriz bi-partida (5 mm diâmetro e 2 mm altura), receberam um dos seguintes tratamentos (n=10): 1) sistema Clearfil SE Bond/Clearfil AP-X (Kuraray), 2) sistema Bistite II DC/Palfique (Tokuyama), 3) sistema Cojet Sand/Z100 (3M-ESPE), 4) jateamento com Al2O3 e sistema Scotchbond Multi Uso Plus/Z100 (3M-ESPE) (grupo controle), e 5) jateamento com Cojet Sand e sistema Scotchbond Multi Uso Plus/Z100. Os corpos-de-prova foram armazenados por 24 horas em água destilada a 37ºC, termociclados (1.000 ciclos - 5º a 55ºC) e, então, deixados nas condições descritas acima por mais 8 dias. O ensaio foi realizado em máquina MTS 810 com velocidade de 0,5 mm/min. Os valores originais foram submetidos à análise de variância (ANOVA) e teste de Tukey. No metal, as médias de resistência dos grupos de 1 a 5 foram respectivamente de 18,40 MPa (B), 8,57 MPa (D), 25,24 MPa (A), 16,26 MPa (BC) e de 13,11 MPa (C) (valor crítico 3,2). Em porcelana, foram de 16,91 MPa (B), 18,04 MPa (AB), 19,54 MPa (AB), 21,05 MPa (A) e de 16,18 MPa (B) (valor crítico 3,7). A melhor opção mediante exposição em metal foi o sistema Cojet Sand. Em porcelana, os sistemas Scotchbond Multi Uso Plus associado ao jateamento com Al2O3, Cojet Sand e Bistite II DC apresentaram os melhores resultados. / Abstract: Fracture of porcelain in metal-ceramic restorations is a common clinical problem and sometimes the repair is a useful solution. Recently some new repair materials with promising results according to their manufactures are available. The aim of this study was to evaluate the shear bond strengths of porcelain repair systems. Fifty disks in NiCr alloy (Vera Bond II) and in feldspatic porcelain (Noritake) were made. The specimens were included in acrylic resin and the surfaces were ground with 320-grit silicon carbide paper. Metal and porcelain specimens were divided into five groups of ten each and the bonding sites received one of the following treatments: 1) Clearfil SE Bond/Clearfil AP-X (Kuraray), 2) Bistite II DC/Palfique (Tokuyama), 3) Cojet Sand System/Z100 (3M-ESPE), 4) air-abrading with Al2O3 and Scotchbond Multi Purpose/Z100 (3M-ESPE) (control group) and 5) air-abrading with Cojet Sand and Scotchbond Multi Purpose/Z100. After storage for 24 hours in distilled water at 37°C, thermocycling (1.000 cycles - 5º and 55ºC) and storage for more 8 days at the same conditions above, the shear bond strength test was performed in a testing machine MTS 810 at a crosshead speed of 0.5mm/min until fracture. Statistical analysis of the data was accomplished by analysis of variance (ANOVA) and Tukey's test. In metal, the bond strengths of groups 1 to 5 were, respectively 18,40 MPa (B), 8,57 MPa (D), 25,24 MPa (A), 16,26 MPa (BC) and 13,11 MPa (C). In porcelain, the bond strengths of the five groups were 16,91 MPa (B), 18,04 MPa (AB), 19,54 MPa (AB), 21,05 MPa (A) and 16,18 MPa (B). The best option when occurs metal exposure is Cojet Sand System. In porcelain, air-abrading with Al2O3 and Scotchbond Multi Purpose, Cojet Sand System and Bistite II DC showed the best results. / Mestre
716

Prótese valvar mitral : 20 anos de seguimento de uma amostra de pacientes operados no Hospital de Clínicas de Porto Alegre, Rio Grande do Sul, Brasil

Ribeiro, Angela Henrique Silva January 2013 (has links)
Este estudo avalia mortalidade, reoperação e eventos hemorrágicos em pacientes submetidos à cirurgia para troca valvar mitral utilizando substituto biológico ou mecânico. O delineamento do estudo foi do tipo coorte histórica. Entre todos os registros, foram selecionados 352 prontuários de pacientes submetidos à cirurgia para troca valvar mitral entre 1990 e 2008, que tiveram seguimento mínimo de 5 e máximo de 23 anos. Para avaliar o tempo de sobrevida, a probabilidade de reoperação e de eventos hemorrágicos, foi utilizada a curva de Kaplan-Meier. Foi aplicado, para comparar as curvas entre os grupos, o teste qui-quadrado de Log-rank. A análise multivariada de Regressão de Cox foi utilizada para identificar preditores independentes de mortalidade, reoperação e eventos hemorrágicos. A sobrevivência em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 87,7%, 74,2%, 69,3% e 69,3% e, para substituto biológico, foi de 87,6%, 71,0%, 64,2%, e 56,6%, respectivamente. Não houve diferença significativa entre a mortalidade entre os dois grupos (p=0,38). Na análise multivariada, os fatores associados com o óbito foram: idade, eventos hemorrágicos e insuficiência renal. A probabilidade de permanecer livre de reoperação em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 94,4%, 92,7%, 92,7% e 92,7% e, para bioprótese, foi de 95,9%, 86,4%, 81,2% e 76,5%, respectivamente (p=0.073), com uma incidência significativamente maior de reoperação para bioprótese (p=0,008). Os fatores associados com reoperação foram: sexo masculino, diâmetro da prótese e endocardite. A probabilidade de permanecer livre de eventos hemorrágicos em 5, 10, 15 e 20 anos após cirurgia utilizando substituto mecânico foi de 95,0%, 91,0%, 89,6% e 89,6% e, para bioprótese, foi de 96,9%, 94,0%, 94,0% e 94,0%, respectivamente (p=0,267). Os fatores associados com eventos hemorrágicos foram: IMC (índice de massa corporal) superior à 30 kg/m2, doença pulmonar obstrutiva crônica, tempo de ventilação mecânica na Unidade de Tratamento Intensivo superior a 30 dias e presença insuficiência mitral. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os dois grupos no seguimento; 2) houve tendência maior à reoperação no grupo com bioprótese; 3) após 10 anos de seguimento, a probabilidade de permanecer livre de reoperação não mudou para pacientes com substitutos valvares mecânicos; 4) a probabilidade de permanecer livre de eventos hemorrágicos não mudou após 10 anos de seguimento para portadores de biopróteses; 5) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 6) o tipo de prótese não foi fator preditor independente associado a nenhum dos desfechos avaliados na análise multivariada. / This study assessed mortality, reoperation and bleeding events in patients who underwent mitral valve replacement surgery with a biological or mechanical substitute. This was a historical cohort study. In total, 352 inpatients clinical health records who underwent mitral valve replacement surgery between 1990 and 2008 with 5 to 23 years of follow-up were selected. A Kaplan-Meier curve was used to evaluate the survival time, the probability of reoperation and bleeding events. A log-rank chi-square test was applied to compare the curves between groups. Multivariate Cox regression analysis was used to identify independent predictors of mortality, reoperation and bleeding events. The 5, 10, 15 and 20 year survival rates after surgery using a mechanical substitute were 87.7%, 74.2%, 69.3% and 69.3%, respectively, while the survival rates after surgery with a biological substitute were 87.6%, 71.0%, 64.2% and 56.6%, respectively. There was no significant difference in mortality between the two groups (p = 0.38). In the multivariate analysis, the factors associated with death were age, bleeding events and renal failure. The probabilities of being free of reoperation at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 94.4%, 92.7%, 92.7% and 92.7%, respectively, while after surgery with a bioprosthesis, they were 95.9%, 86.4%, 81.2% and 76.5%, respectively (p = 0.073); therefore, there was a significantly higher incidence of reoperation for patients receiving a bioprosthesis (p = 0.008). The factors associated with reoperation were male gender, diameter of the prosthesis and endocarditis. The probabilities of remaining free of bleeding events at 5, 10, 15 and 20 years after surgery using a mechanical substitute were 95.0%, 91.0%, 89.6% and 89.6, respectively, while after surgery with a bioprosthesis, they were 96.9%, 94.0%, 94.0% and 94.0%, respectively (p = 0.267). The factors associated with bleeding events were BMI (body mass index) greater than 30 kg/m2, chronic obstructive pulmonary disease, mechanical ventilation at an Intensive Care Unit for longer than 30 days and mitral regurgitation. The authors concluded that: 1) mortality during follow-up was statistically similar in both groups; 2) there was a greater tendency to reoperation in the bioprosthesis group; 3) the probability of survival free from reoperation did not change for patients with mechanical valves after 10 years’ follow-up; 4) the probability of survival free from bleeding events did not change after 10 years’ follow-up for bioprostheses patients; 5) patients’ baseline characteristics were the greatest determinants of late mortality after mitral valve replacement surgery; 6) the type of prosthesis fitted was not an independent predictive factor of any of the outcomes analyzed in the multivariate analysis.
717

Análise biomecânico por meio de elementos finitos da distribuição de tensões em implantes e osso perimplantar com diferentes diâmetros e comprimentos posicionados na região anterior da maxila / Biomechanical analysis through finite element of stress distribution in implants and surrounding bone with differents diameter and length located in the anterior maxilla.

Eduardo Andrés Borie Echevarria 29 August 2013 (has links)
A reabilitação da região anterior com próteses sobre implantes é um procedimento complexo pela quantidade de fatores que devem ser controlados. Nos casos em que o paciente apresenta estruturas anatômicas ou deficiências ósseas na região da prémaxila, que impeçam o ideal posicionamento de todos os implantes possíveis, o clínico deverá escolher entre um planejamento com prótese em cantilever ou fixa convencional. O sucesso clínico de reabilitação com implantes está relacionado, principalmente, pelo modo com que as tensões mecânicas são transferidas do implante para o osso circundante, sem gerar tensões que possam colocar em risco a longevidade dos implantes e próteses. Assim, o objetivo deste estudo foi avaliar, por meio de análise de elementos finitos, a distribuição de cargas em planejamento com implantes na região anterior da maxila em diferentes posições (incisivo central e lateral), conexões (cone morse e hexágono externo), diâmetros (4mm e 3,75mm), comprimentos (8,5mm e 10mm) e material restaurador (metalocerâmica e resina acrílica). Um modelo de maxila foi obtida a partir de um banco de dados e transformada em um modelo tridimensional por meio do software Invesalius v.3.0. O modelo da maxila foi simplificado e considerada a espessura de 2mm de osso cortical. Os modelos dos implantes utilizados foram fornecidos pela empresa em formato virtual. Foram criados modelos de prótese em cantilever com implantes de 4mm de diâmetro na região dos incisivos centrais e prótese fixa convencional com implantes de 3,75mm de diâmetro na região dos incisivos laterais, ambos com conexões de hexágono externo e cone morse, com comprimentos de 8,5 e 10 mm e restaurações em resina acrílica e metalocerâmicas. Os modelos foram simulados aplicando uma carga oblíqua estática de 150 N em 45º em relação ao longo eixo do implante, distribuída no cíngulo dos quatro incisivos, sendo 37,5 N em cada elemento dental. Os implantes, componentes protéticos, copings e subestrutura metálica foram analisados com tensão equivalente Von Mises, porém as tensões perimplantares no osso cortical e na região apical do osso trabecular, foram analisadas por tensões máxima e mínima principais e deformações máxima e mínima principais. O deslocamento também foi considerado em ambos os tipos de restaurações e a análise geral foi feita em todos os modelos tanto qualitativa quanto quantitativamente. Na análise foi observado que a tensão máxima e mínima principal ocorreu sempre no osso cortical, identificando maiores valores na tensão por compressão. Além disso, o planejamento, seja prótese em cantilever ou fixa convencional, comprimento e sistema de conexão, influíram nas tensões do osso cortical, mas não nas deformações do trabecular. As variáveis que mostraram menores tensões principais na estrutura óssea perimplantar foram: prótese em cantilever, conexão cone morse, implantes com comprimento de 8,5mm e restaurações metalocerâmicas. Com relação à tensão equivalente Von Mises, a conexão cone morse apresentou concentração das tensões máximas na união entre o pescoço do implante e pilar, enquanto o hexágono externo concentrou as tensões na subestrutura metálica, plataforma do pilar e roscas do implante. Os modelos em resina acrílica exibiram os maiores valores de deslocamento. Finalmente, todos os modelos apresentaram valores de tensão e deformação dentro dos limites fisiológicos. / Anterior region rehabilitation thorugh implant-supported prosthesis is a complex procedure by the amount of critical factors that must be controlled. In some cases, when patient has bone defects or anatomic structures in the premaxilla, which avoid the ideal number of implant placement, the clinical must choose between a plan with cantilever or conventional fixed prosthesis. The clinical success with implant rehabilitation is mainly related to the way that mechanical stresses are transferred from the implant to surrounding bone without creating overload that will endanger the long life of implants and prostheses. The aim of this study was to assess through finite element analyses the load distribution in planning with implants located at maxilla anterior region with different positions (central and lateral incisor), connection (external hexagon and morse taper), diameter (4mm and 3.75mm), lengths (8.5mm and 10mm), and restorative material (metalloceramic and acrylic resin). A maxilla image was obtained from a database and converted into a three-dimensional model through InVesalius software v.3.0. The model was simplified and considered a cortical bone thickness of 2mm. Implant models were provided by the company in a virtual file. Models with 4mm in diameter cantilever prosthesis at the central incisor area and 3.75mm in diameter conventional fixed prosthesis at the lateral incisor were developed. Both kinds of models had external hexagon and morse taper connections, lengths of 8.5 and 10mm and metalloceramic and acrylic resin restorations. The models were loaded with 150 N at an angle of 45º to the long axis of implant, at the cingulum area and with a magnitude of the force applied on each unit of 37.5 N. Implants, abutments, copings and metallic substructures were analyzed through Von Mises equivalent stress. However, stresses of perimplantar bone, cortical and trabecular bone were analyzed through maximum and minimum principal stresses, and maximum and minimum principal strains. Also, total deformation was regarded in both kinds of restorations and a general analysis was performed on all models qualitatively and quantitatively. The analyses showed that maximum and minimum principal stresses were identified in all models on cortical bone, observing the higher compression stress values. Moreover, the planning, cantilever or conventional fixed prosthesis, length and connection system influenced the principal stresses on cortical bone but not the strains on trabecular bone. The factors that exhibited the lowest principals stresses in peri-implant bone structure were: cantilever prosthesis, morse taper connection, implant length of 8,5mm and metal-ceramic restoration. Regarding Von Mises equivalent stress, morse taper connection showed a maximum concentration stresses located in the joint between the implant neck and abutment, while external hexagon exhibited stress concentration in the metallic structure, abutment and implant screws. The models with acrylic resin restorations showed the highest total deformation. Finally, all stresses and strains observed were found within physiological limits.
718

Acionamento e controle de um dedo de uma prótese para membro superior com realimentação proprioceptiva de força e temperatura

Vanderlei de Oliveira Del Cura 14 June 2005 (has links)
Este trabalho visa contribuir para redução do grau de rejeição de próteses para membros superiores, tornando-as mais funcionais e eficientes. Tais propósitos são almejados por meio do estudo centrado no desenvolvimento de uma plataforma eletrônica de controle e nos demais constituintes de uma prótese. Dentre eles estão os atuadores, sensores, mecanismos e o programa de gerenciamento, que integra todos os componentes para as ações da prótese. Para esse trabalho foi usado somente um dedo para a execução de todos os testes, sendo esse dedo compatível com o desenvolvimento de uma prótese antropomórfica multifunção. O paciente comanda as ações da prótese ao enviar suas decisões à ela por meio de sinal mioelétrico, mas as ações da mesma são executadas de forma inconsciente. Isto é possível devido ao programa de gerenciamento, que controla os movimentos antropomórficos a partir de trajetórias definidas e também pelas informações de sensações de força e temperatura para o paciente, realimentação proprioceptiva. / This work contributes to minimize the rejection level of upper limb prosthesis, keeping it more function and efficient. This achieved by the development of a control electronic platform and the others prosthesis components, like actuators, sensors, mechanisms and the management program, that integrate all the components to actions of prosthesis. In this work was used only one finger to perform of all tests, and this finger is compatible with the development of a multifunction anthropomorphic prosthesis. The user command comes from myoelectric signal, but the actions in the prosthesis are executed unconsciously. The management program control the anthropomorphic movements based on defined trajectory and create information of force and temperature sensation to the user, proprioceptive feedback.
719

"Implante de stent revestido com paclitaxel em pacientes com infarto agudo do miocárdio em comparação com stent convencional: um estudo prospectivo, com avaliação clínica, angiográfica e ultra-sonográfica" / Paclitaxel-eluting stent implantation for acute myocardial infarction in comparison with conventional stenting : a clinical, angiographic, and IVUS prospective study

Fernando de Martino 13 January 2006 (has links)
Fundamentos: Este estudo tem o objetivo de comparar os resultados clínicos e angiográficos de pacientes com infarto agudo do miocárdio(IAM) tratados com implante de stent revestido com paclitaxel (SRP) versus stent convencional. Métodos e população do estudo: Um grupo de 30 pacientes com infarto agudo do miocárdio foi tratados com stent revestido com paclitaxel (TaxusTM). Um grupo controle com 30 pacientes foi tratado com stent convencional (Express2 TM).Resultados: Aos 6,9±1,2 meses, não ocorreu morte, reinfarto ou trombose intra-stent. Entretanto, pacientes tratados com stent farmacológico tiveram um risco menor de reintervenção (3.3%% vs. 33.3%; p=0.006). A perda luminal tardia foi de 0.2±0.2 mm no grupo de SRP vs. 0.6±0.6 mm (p=0.03) no controle e a reestenose binária foi de 3.3% (RVP)vs. 33.3%(controle) (p=0.006). O percentual médio de obstrução neointimal em pacientes do grupo farmacológico foi de 4,7%±6,8%. Conclusões: O SRP se mostrou seguro e efetivo aos 7 meses em pacientes com IAM / This study aimed to compare the clinical and angiographic outcomes of patients with acute myocardial infarction (AMI) treated with paclitaxel eluting stent (PES) versus conventional stent implantation. Methods and Study Population: A group of 30 patients admitted with AMI was treated with PES (TaxusTM). A control group comprised 30 patients with a similar bare stent (Express IITM). Results: Baseline and procedural characteristics were similar between the PES and control groups. At 6.9±1.2 months, there were no deaths, re-AMI, or stent thrombosis. However, patients treated with PES had a lower risk of repeat revascularization (3.3%% vs. 33.3%; p=0.006). The angiographic late loss was 0.2±0.2 mm vs. 0.6±0.6 mm (p=0.03) and the binary restenosis rate was 3.3% vs. 33.3% (p=0.006) in the PES vs. controls respectively. The average percent neointimal obstruction in patients treated with PES was 4.7±6.8 %. Conclusions: PES appeared safe and effective at 7 months in patients AMI
720

Próteses parciais fixas apoiadas sobre conexão dente-implante rígida: análise do comportamento biomecânico antes e após ciclagem mecânica / Tooth-implant supported rigid connected fixed partial dentures: Biomechanical behavior analysis before and after mechanical cycling

Glauber Macedo Rama 10 September 2014 (has links)
A associação entre dente e implante em uma prótese parcial fixa (PPF) vêm sido questionada há muitos anos devido a suas implicações clínicas, incluindo a seleção do melhor tipo de união dos elementos protéticos (conexão rígida ou semi-rígida). Este estudo avaliou próteses dento-implanto-suportadas de conexão rígida do tipo cimentada sobre 3 tipos de conexão protética (hexágono externo - HE, hexágono interno - HI e cone morse - CM) e sua relação com o desajuste vertical e falhas na prótese antes e após ciclagem mecânica, além da análise fotoelástica destas situações. Foram confeccionados 21 corpos de prova (7 HE, 7 HI e 7 CM) sobre um modelo mestre que simulou a perda dentária dos elementos 46 e 47, sendo um implante posicionado na área do 47 e um dente preparado com ligamento periodontal simulado em poliéter na área do 45. Sobre este modelo foram confeccionadas PPFs metalocerâmicas de 3 elementos rígidas cimentadas sobre dente e implante (munhão universal). Os corpos de prova foram preparados e submetidos ao ensaio de ciclagem mecânica com uma carga de 120N por 1.000.000 de ciclos, simulando o uso clínico da prótese por 2 anos. Análises do desajuste vertical foram realizadas por meio de microscopia óptica (40x) em todos os períodos de confecção das PPFs (antes da solda, após solda, após aplicação da cerâmica e após ciclagem). O percentual de falhas nas próteses após ciclagem também foi avaliado (trincas/fraturas/decimentações), além da execução do ensaio fotoelástico (carga pontual dental, bipontual nos pilares e oclusal simultânea). Os resultados obtidos para o desajuste vertical indicaram um aumento significante dos níveis de desajuste para todas as etapas de confecção tanto para dente quanto implante (p<0,0001), porém não significante entre os grupos (p>0,059). Para o percentual de falhas na prótese, encontrou-se um índice decrescente na ordem CM>HI>HE. Para análise fotoelástica, encontrou-se um índice de concentração de tensões crescente na ordem CM&lt;HI&lt;HE. Baseado nos resultados encontrados, dentro das limitações do estudo foi possível concluir que: os níveis de desajuste vertical tendem a aumentar nas etapas de confecção da prótese para todas as conexões protéticas; a fadiga mecânica tende a interferir no grau de desajuste vertical a longo prazo pela deformação da estrutura a depender de sua espessura; o aumento no percentual de falhas da prótese tende a ser proporcional ao aumento da rigidez da conexão protética; apesar da redução da rigidez da conexão protética favorecer a longevidade da PPF, esta também tende a aumentar as tensões nos elementos pilares e stress no osso circundante; a utilização da conexão Morse subcrestal para união dente-implante rígida tende a ser preferível pela preservação dos elementos pilares devido a menor concentração de tensões em detrimento da longevidade da PPF, entretanto esta pode ser substituída caso a falha seja irreversível. / The association between tooth and implant in fixed partial dentures (FPD&prime;s) have been questioned for many years due to its clinical implications, including selecting the best kind of connection design (rigid or semi-rigid connection). This study assessed cemented toothimplant supported rigid connected FPD&prime;s on 3 types of implant connections (external hexagon - EH, internal hexagon - IH and morse taper - MT) and its relationship to the vertical misfit and FPD failure before and after mechanical cycling plus the photoelastic analysis of those situations. 21 specimens (7 EH, 7 IH and 7 MT) were fabricated on a master model that simulated tooth loss of elements 46 and 47, with an implant placed on the 47 area and a prepared tooth with simulated periodontal ligament in polyether on the 45 area. On this model, three-element metalloceramic rigid FPD&prime;s were made, cemented to tooth and implant (universal post). The specimens were prepared and subjected to mechanical cycling with a 120N load under 1,000,000 cycles, simulating a 2-year clinical use of the prosthesis. Analyses of vertical misfit were performed by optical microscopy (40x) in all periods of FPD&prime;s fabrication (before welding, after welding, after application of ceramic and after cycling). The FPD failure percentage after cycling was also evaluated (cracks/fractures/loss of cementation), and photoelastic test was performed (dental load only, simultaneous abutment load and occlusal load). The results for vertical misfit indicated a significant increase in the levels of misfit for all stages of fabrication for both tooth and implant (p<0.0001) but not significant between groups (p>0.059). For the FPD failure percentage, we found a decreasing rate in the order MT>IH>EH. The photoelastic test indicated a major amount of tension increase in the order MT&lt;IH&lt;EH. Based on these results, within the limitations of the study it was concluded that: the levels of vertical misfit tend to increase in the prosthesis fabrication steps for all implant connections; mechanical fatigue tends to interfere on vertical misfit in long term due to deformation of the framework depending on its thickness; the FPD failure percentage tends to be proportional to the rigidity increase of the implant connection; despite the decrease of rigidity of the implant connection favors the longevity of the FPD, this also tends to increase tensions on the abutments and stress on the surrounding bone; the use of subcrestal morse taper connection on rigid tooth-implant FPD&prime;s tends to be preferable for the preservation of the abutments due to the lower abutment stress concentration at the expense of longevity of FPD, though this can be replaced if the failure is irreversible.

Page generated in 0.0765 seconds