• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 246
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 253
  • 177
  • 171
  • 160
  • 98
  • 36
  • 35
  • 34
  • 32
  • 32
  • 31
  • 30
  • 29
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Controle estatístico de qualidade aplicado a ensaios de material de irrigação / Statistical quality control applied to irrigation materials testing

Rocha, Hermes Soares da 30 November 2016 (has links)
Os ensaios laboratoriais para avaliação técnica ou estudo de material de irrigação envolvem a medição de diversas grandezas, bem como o monitoramento e controle das condições de ensaio. Qualquer sistema de medição e controle naturalmente apresenta instabilidades que podem afetar a qualidade dos resultados de ensaio, implicando em aumento da incerteza no processo de medição. A implementação do Controle Estatístico de Qualidade pode ser promissora para detecção de causas externas de variação, avaliação da variação máxima permitida aos dados de um processo e discriminação das principais componentes de variabilidade de um sistema de medição. Nesse sentido, considerando a hipótese de possibilidade de aprimoramento da qualidade dos resultados de ensaios, a presente pesquisa teve por objetivo utilizar técnicas de controle estatístico de qualidade e análise de sistemas de medição para avaliar o grau de adequação de bancadas de ensaio de emissores de microirrigação, aperfeiçoar os sistemas de medição e controle adotados nas bancadas e diagnosticar a porcentagem de contribuição dos fatores inerentes aos sistemas de medição e controle na variabilidade total das medidas de vazão em ensaios de uniformidade. A pesquisa foi conduzida no Laboratório de Ensaios de Material de Irrigação (LEMI/INCTEI/ ESALQ/USP). Foram elaborados gráficos de controle de Shewhart, média móvel exponencialmente ponderada (MMEP), além de índices de capacidade para o processo de medição da pressão de ensaio, monitoramento de temperatura da água e vazão, consideradas como as variáveis características da qualidade para ensaios de determinação das curvas de vazão em função da pressão de entrada e uniformidade de vazão de emissores de microaspersão e gotejamento. Além disso, realizou-se estudo de repetitividade e reprodutibilidade (Gage RR) do sistema de medição da vazão, para o qual foram utilizadas 10 repetições, sob três turnos de trabalho (manhã, tarde e noite), com 13 emissores na bancada de microaspersão e 25 emissores na bancada de gotejamento. Não houve influência do turno de trabalho nas medidas de vazão obtidas e o aprimoramento do processo de ajuste da pressão de ensaio pela implantação de um controlador proporcional integrativo-derivativo (PID) ao ensaio de microaspersores foi suficientemente detectado pela aplicação dos gráficos de controle. A pressão e temperatura da água se mantiveram estáveis durante cada ensaio, e não foram identificadas causas não aleatórias de variabilidade na rotina de ensaios. O processo de controle e medição da pressão, para as duas bancadas, foi classificado como\"excelente\" quanto ao desempenho e capacidade de se manter entre os limites de especificação e centralização em relação ao valor de referência (alvo desejado). Como esperado, a variabilidade entre emissores foi a componente de maior contribuição na variância total da vazão, correspondendo a 95,47% e 96,77% para microaspersão e gotejamento, respectivamente. A repetitividade e reprodutibilidade do sistema de medição de vazão (Gage RR) foi \"aceitável\" para as duas bancadas, com as respectivas contribuições de 4,53% e 3,23%, em relação à variância total, associados às incertezas do Gage RR. / Laboratory tests for technical evaluation or irrigation material testing involve the measurement of various greatnesses, as well as monitoring and control of test conditions. Any measurement and control system naturally presents instabilities that can affect the quality of the test results, resulting in increased measurement uncertainty. The implementation of the Statistical Quality Control may be promising for detecting causes of variation non-random, evaluation of the tolerance permitted to data of the process and breakdown of the main variability components of a measuring system. In this sense, considering the hypothesis of possibility of improving the quality of test results, the present study aimed at using statistical quality control techniques and measurement systems analysis to assess the reliability of test benches of microirrigation emitters, improve measurement and control systems adopted in the benches and to diagnose percentage of contribution of the factors inherent in the measurement and control systems in the total variability of flow measurements on uniformity tests. The research was carried in Laboratório de Ensaios de Material de Irrigação (LEMI/INCTEI/ ESALQ/USP). Shewhart control charts were developed, exponentially weighted moving average (EWMA), and capability index for the process of measuring the test pressure, temperature monitoring of water and flow, regarded as the quality variables for determination the flow curves as a function of inlet pressure and uniformity of flow for microsprinkler emitters and drip. In addition, it was made study of repeatability and reproducibility (Gage RR) of flow measurement system for which were used 10 repetitions in three work shifts (morning, afternoon and evening), with 13 emitters in the microsprinkler\'s bench and 25 emitters in the drip bench. There wasn\'t influence of the work shift in the obtained measures for flow and the improvement of the adjustment process of the test pressure for the implementation of the integrative-derivative proportional controller (PID) to microsprinklers test was sufficiently detected by control charts. The pressure and water of temperature remained stable during the tests and weren\'t identified non-random causes of variability in routine tests. The process control and measurement of pressure was classified \"excellent\" to performance and capability to remain in the range of specification and centralization in relation to the reference value (desired target), to the two benches. As expected, the variability between emitters was the greater contribution component in the total variance of flow, corresponding to 95.47% and 96.77% for microsprinkler and drip, respectively. The repeatability and reproducibility for flow measurement system (Gage RR) was \"acceptable\" for the two benches, with the contributions respective of 4.53% and 3.23% relative to the total variance, associated with uncertainties of Gage RR.
162

Validação da escala de avaliação da qualidade de vida na doença cerebrovascular isquêmica para a língua portuguesa / Validation of the stroke specific quality of life scale to Portuguese language

Santos, André Sobierajski dos 16 March 2007 (has links)
Introdução: A medida da qualidade de vida relacionada à saúde vem se tornando um modelo importante de avaliação em muitos estudos clínicos. Especial consideração deve ser dada à doença cerebrovascular por ser freqüente e de graves conseqüências físicas, sociais, familiares e econômicas. No Brasil não dispomos de um instrumento específico de avaliação da qualidade de vida validado para uso em pacientes com doença cerebrovascular isquêmica. Este estudo avaliou as medidas psicométricas do instrumento de avaliação da qualidade de vida específico para a doença cerebrovascular do tipo isquêmico, adaptado transculturalmente para a língua portuguesa (Stroke specific quality of life scale, SS-QOL). Metodologia: Foram avaliados 50 pacientes com história de doença cerebrovascular do tipo isquêmico, com idade superior a 45 anos e com evolução clínica superior a 3 meses da data do íctus, assistidos no Centro Catarinense de Reabilitação em Florianópolis, Santa Catarina. O instrumento SS-QOL foi aplicado em duas entrevistas com intervalo médio, entre elas, de 2 a 4 semanas. Paralelo a esta medida, foram aplicados, na primeira entrevista, os instrumentos: índice Barthel, inventário de depressão de Beck, escala de doença cerebrovascular do Instituto Nacional de Saúde dos Estados Unidos da América (NIHSS) e o estudo de resultados médicos - versão curta de 36 itens (SF-36). A avaliação da confiabilidade (estabilidade e consistência interna) do SS-QOL foi testada por meio da análise do coeficiente de confiabilidade, com o modelo teste-reteste, e do valor alfa de Cronbach. A validação do constructo e de critério foi estabelecida através da correlação linear entre os resultados obtidos para cada domínio e os resultados obtidos nas medidas escolhidas como padrão ouro para aquele domínio medido pelo coeficiente de correlação de Pearson (r). A capacidade discriminativa do constructo foi testada comparando o escore médio do SS-QOL entre os pacientes que referiam alteração da qualidade de vida e os pacientes que não referiram alteração da qualidade de vida em relação à época antes do infarto cerebral. Ela também foi avaliada comparando o escore médio do SS-QOL em relação à gravidade clínica da doença medida pela escala NIHSS e pelo grau de incapacidade funcional avaliado pela escala de Rankin modificado. Resultados: O SS-QOL, versão para a língua portuguesa, apresentou boa aceitabilidade, não tendo informações perdidas nem porcentagem aumentada de respostas com efeito teto ou solo. A confiabilidade do instrumento foi considerada excelente, com coeficiente de correlação intraclasse de 0,95 (p < 0,001) e o valor alfa de Cronbach de 0,98 (p < 0,001). O grau de correlação linear dos domínios do SS-QOL com as demais medidas escolhidas para cada domínio foi considerado de razoável a moderadamente elevado, com valor de r variando de 0,42 a 0,91 (p < 0,01). O SS-QOL mostrou capacidade discriminativa adequada ao detectar diferenças estatisticamente significantes no escore médio dos pacientes que referiram alteração da qualidade de vida e dos que não alegaram alteração da qualidade de vida em relação a antes de a doença ter ocorrido e no escore médio dos pacientes com doença considerada leve em relação aos pacientes com doença considerada moderada (p < 0,001). A análise de variância revelou diferenças estatisticamente significantes no escore médio dos pacientes estratificados pelo grau de incapacidade funcional (p < 0,01). Conclusão: O SS-QOL, adaptado para a língua portuguesa, apresentou medidas psicométricas consideradas satisfatórias, estando adequado para a utilização como uma ferramenta de avaliação da qualidade de vida em pacientes com doença cerebrovascular na prática médica diária ou em estudos clínicos. / Introduction: Measurement of health related quality of life has become an important evaluation model in many clinical studies. Special consideration must be given to the cerebrovascular disease because it is frequent and has serious physical, social, familial and economic consequences. We do not have, in Brazil, a specific instrument to evaluate health related quality of life validated for stroke patients. This study evaluates psychometric measures of the stroke specific quality of life scale cross-culturally adapted to Portuguese language (SS-QOL). Methodology: We evaluated 50 stroke patients, admitted to the Centro Catarinense de Reabilitação in Florianópolis, Santa Catarina, older than 45 years old with time of lesion superior to 3 months. The SS-QOL was applied in two interviews with average interval, between them, of 2 to 4 weeks. Parallel to the instrument, we applied, in the first interview, the Barthel index, Beck depression inventory, National Institute of Health stroke scale (NIHSS) and the Medical outcome study - short version of 36 items (SF-36). The SS-QOL reliability evaluation (stability and internal consistency) was tested with the analysis of the stability coefficient with test-retest model, and the Cronbach?s alpha value. The construct and criterion validation was established by comparing the linear correlation between the results for each domain and the results of the chosen gold standard measures for that domain measured with Pearson correlation coefficient (r). The discriminant capacity was tested comparing the SS-QOL mean scores of patients who referred changes in the quality of life and those that did not refer it in relation to the prestroke period. It was also evaluated comparing the SS-QOL mean score in relation to disease clinical gravity measured with the NIHSS and the degree of functional incapacity evaluated by Rankin modified scale. Results: The SS-QOL, Portuguese language version has good acceptability. It does not have missing data or increased percentage of ceiling or floor effect. The stability was considered excellent with intraclass correlation coefficient of 0,95 (p < 0.001) and the Cronbach?s alpha value of 0,98 (p < 0,001). The degree of linear correlation of the SS-QOL domains with the chosen measures for each domain was considered reasonable to moderately high with r values varying from 0,42 to 0.91 (p < 0,01). The SS-QOL presented suitable discriminant capacity detecting differences, statistically significant, in the mean score of patients who had referred changes in the quality of life and those that did not refer it in relation to the prestroke period and in the mean score of patients with mild stroke and those with moderate stroke. The variance analysis showed statistically significant differences in the mean score of patients stratified by the functional incapacity degree (p < 0.01). Conclusion: The SS-QOL, adapted to Portuguese language, had psychometric measures considered satisfactory. It is suitable to use as a tool of quality of life evaluation in patients with stroke in the daily clinical practice or clinical studies.
163

Reprodutibilidade do teste de sobrecarga hídrica em portadores de glaucoma de ângulo aberto sob tratamento clínico / Reproducibility of the water drinking test in treated glaucomatous patients

Babic, Mirko 28 April 2017 (has links)
OBJETIVO: avaliar a reprodutibilidade dos picos de pressão intraocular e a flutuação obtidas durante o teste de sobrecarga hídrica em pacientes glaucomatosos tratados com um longo intervalo de seguimento. MÉTODOS: análise retrospectiva de 34 pacientes portadores de glaucoma primário de ângulo aberto, sob tratamento clínico, atendidos durante o período de uma semana no ambulatório de um dos investigadores (RSJ). Os pacientes foram submetidos ao teste de sobrecarga hídrica, realizado em duas visitas consecutivas, sem alteração do regime terapêutico. O intervalo médio entre os testes foi de 4,85 (intervalo, 3-6) meses. A reprodutibilidade do pico e a flutuação durante o teste de sobrecarga hídrica foram avaliadas utilizando coeficientes de correlação intraclasse. A análise de Bland-Altman foi utilizada para avaliar a concordância entre os picos de pressão intraocular e a flutuação, medidos entre dois testes consecutivos. RESULTADOS: trinta e quatro olhos de 34 pacientes foram estudados. Não houve diferenças significativas nos valores de pressão intraocular basal (média ± desvio-padrão, 11,73 ± 2,36 e 11,61 ± 2,71 mmHg; p = 0,72) e picos (14,55 ± 3,41 e 15,02 ± 3,66 mmHg, respectivamente; p = 0,163) detectados durante o teste de sobrecarga hídrica entre a primeira e a segunda visitas. Também não houve diferença significativa entre os valores médios de flutuação da pressão intraocular (2,82 ± 1,99 e 3,41 ± 2,54 mmHg, respectivamente; p = 0,135). Os picos de pressão intraocular e a flutuação apresentaram coeficientes de correlação intraclasse de 0,85 (p < 0,001) e 0,50 (p < 0,001), respectivamente. CONCLUSÕES: neste estudo, os resultados demonstraram excelente reprodutibilidade dos picos de pressão intraocular durante o teste de sobrecarga hídrica. Entretanto, a flutuação da pressão intraocular não revelou boa reprodutibilidade / OBJECTIVE: To evaluate the reproducibility of intraocular pressure peaks and fluctuation elicited during the water drinking test in treated glaucomatous patients with a long follow-up interval. METHODS: 34 treated primary openangle glaucoma patients evaluated in retrospective cohort study in a tertiary care practice. All patients underwent the water drinking test performed in two consecutive visits without any change in the therapeutic regimen. The mean interval between tests was 4.85 (range, 3-6) months. Reproducibility of peak and fluctuation during the water drinking test was assessed using intraclass correlation coefficients. Bland-Altman analysis was used to assess the agreement of intraocular pressure peaks and fluctuation measured between two consecutive tests. RESULTS: There were no significant differences in baseline intraocular pressure values (mean ± standard deviation, 11.73 + 2.36 and 11.61+2.71 mmHg; p=0.72) and peaks (14.55+3.41 and 15.02 ± 3.66 mmHg, respectively; p=0.163) detected during the water drinking test between the first and second visits. There was also no significant difference between the average intraocular pressure fluctuation values (2.82 ± 1.99 and 3.41 ± 2.54 mmHg, respectively; p=0.135). Intraocular pressure peaks and fluctuation presented intraclass correlation coefficients of 0.85 (p < 0.001) and 0.50 (p < 0.001), respectively. CONCLUSIONS: Our results demonstrate excellent reproducibility of intraocular pressure peaks during the water drinking test. Intraocular pressure fluctuation did not reveal good reproducibility, though
164

Elaboração e análise de confiabilidade de escala de avaliação funcional do subir e descer escada para portadores de distrofia muscular de Duchenne (DMD) / Reliability of the evaluation of going up and down stairs for DMD

Fernandes, Lilian Aparecida Yoshimura 05 August 2009 (has links)
Instrumentos descritivos de avaliação funcional para portadores de distrofia muscular de Duchenne são limitados, pois classificam e não qualificam e/ou quantificam o desempenho motor. OBJETIVO: Elaborar escala de avaliação funcional do subir e descer escada para portadores de distrofia muscular de Duchenne e analisar confiabilidade intra e inter-examinadores. MÉTODO: 1. Elaboração de guia de avaliação a partir de revisão da literatura. 2. Avaliação do subir e descer escada de 120 registros filmados de 30 crianças com DMD (5 a 11 anos), utilizando o guia. 3. Elaboração da escala considerando grau de dificuldade. 4. Avaliação por peritos e reajustes para geração da versão final da escala e seu manual. 5. Análise estatística utilizando Índice de Correlação Intra-Classe e Correlação de Kappa Ponderado. RESULTADOS: A escala abrange cinco fases para o subir e quatro para o descer escada. Deve ser aplicada por profissional treinado, conforme normas do manual. Encontrou-se classificação excelente na análise da confiabilidade intra e interexaminadores, com valores da Correlação de Kappa Ponderado (> 0.78) e ICC > (0.89), com p < 0.05 entre todas as fases. CONCLUSÃO: A escala pode ser utilizada como ferramenta de avaliação fisioterapêutica descritiva e quantitativa com excelente repetibilidade e reprodutibilidade / Descriptive instruments of functional evaluation for carriers of duchenne muscular dystrophy are limited, because, they classify and do not qualify and/or quantify the motor performance. OBJECTIVE: To elaborate a scale of functional evaluation of going up and down stairs for DMD carriers and to analyze the realibility intra and inter examiner. METHODS: Elaboration of an evaluation guide from the literature review. 2. Evaluation of 120 registers filmed from 30 children (5 to 11 years) with duchenne muscular dystrophy going up and down stairs, using the guide. 3. Elaboration of the scale considering the degree of difficulty. 4. Evaluation by connoisseurs and readjustments for generation of the final version of the scale and its manual. 5. Statistical analysis using Intra-class Correlation Coefficient and Weighed Kappa. RESULTS: The scale encloses five phases for going up and four for going down stairs. It has to be applied by a trained professional, as norms of the manual. It was found an excellent classification on the reliability analysis intra and inter examiner, with values of Weighed Kappa Coefficient (> 0.78) and ICC > (0.89), with p < 0.05 between all phases. CONCLUSION: The scale can be used as a tool of physical therapy evaluation descriptive and quantitative with excellent repeatability and reproducibility
165

Validação do questionário do sono infantil de Reimão e Lefèvre (QRL) / The Infant Sleep Questionnaire Reimão and Lefèvre validation (RLQ)

Araujo, Patricia Daniele Piaulino de 04 May 2012 (has links)
INTRODUÇÃO: Na população infantil, a presença da privação ou de alterações no padrão do sono interfere em diversos processos orgânicos, além de influenciar no comportamento e humor, no desempenho neuropsicomotor, na cognição e nos relacionamentos sociais e familiares, prejudicando sua qualidade de vida. Entre os métodos diagnósticos utilizados na investigação dos distúrbios do sono para essa população incluise a utilização de questionários. Estes são instrumentos de simples administração que facilitam o diagnóstico e determinam a presença de distúrbios do sono e parassônias em crianças. O Questionário do Sono de Reimão e Lefèvre (QRL) é um instrumento de avaliação subjetiva desenvolvido em território nacional, que validado, contribuirá para pesquisas clínicas e epidemiológicas, facilitando também a prática clínica do profissional que atua nessa área. OBJETIVOS: 1)verificar se as propriedades de validade (consistência interna e reprodutibilidade) do QRL permitem que este assuma o papel de um instrumento específico de avaliação de características e distúrbios do sono para a população infantil; 2)determinar a prevalência dos distúrbios do sono relacionados às crianças de três a cinco anos de idade e aos seus diferentes gêneros; 3)estabelecer as características do padrão de sono para crianças de três a cinco anos e; 4)conhecer os principais hábitos e rituais para dormir que crianças com essa faixa etária manifestam. MÉTODOS: Estudo prospectivo e observacional para a avaliação da consistência interna e reprodutibilidade do QRL. Para a avaliação da consistência interna, 60 crianças entre três e cinco anos de idade foram divididas em três subgrupos após diagnóstico médico: GICrianças com diagnóstico de distúrbio do sono; GII- Crianças sem a presença de qualquer distúrbio do sono; GIII- Crianças com ou sem a presença de distúrbio do sono. Os resultados do QRL foram comparados com o diagnóstico feito pelo médico neurologista especialista na área do sono. Para o estudo da reprodutibilidade, o questionário foi aplicado em 1021 crianças entre três e cinco anos de idade de creches municipais de São Paulo e reaplicado após um período que variou entre 14 e 21 dias. RESULTADOS: Os índices de correlação entre o QRL e o diagnóstico médico foram elevados nos três grupos estudados, com alta consistência interna (0,80 a 0,86) segundo Coeficiente Alfa de Cronbach. As questões do QRL apresentaram alta concordância para a reprodutibilidade (0,798 a 1,000) segundo coeficiente Kappa. O tempo total de sono variou entre 10 e 11 horas para as crianças entre três e cinco anos. A movimentação excessiva durante o sono (48,5%), o ronco (35,8%), sonolência diurna (33,2%) e enurese noturna (21,9%), foram os distúrbios com maior prevalência. A maior parte dos distúrbios do sono ocorreu diariamente, foram mais comuns ao gênero feminino e tenderam a diminuir com a idade. CONCLUSÕES: A consistência interna e a reprodutibilidade do QRL indicaram que esse é um instrumento adequado para avaliar a presença de distúrbios do sono na população infantil. A prevalência dos distúrbios do sono variou de acordo com o gênero, idade e frequência da manifestação / INTRODUCTION: The pediatric population, sleep deprivation and disturbance of sleep pattern influences several organic process, also influences behavior and mood, neuropsychomotor performance, cognition and relationships, and it is detrimental to quality of life. The diagnostic method used in this population also includes the use of questionnaires. Sleep questionnaires are instruments which easily assist to diagnose sleep disorders and parasomnias in children. Infant Sleep Questionnaire Reimão and Lefèvre (RLQ) is an instrument of subjective evaluation, developed in Brazil, and if validated, will be very helpful for clinical and epidemiologic research as well as for clinical practice. OBJECTIVES: Is to check validity (internal consistency and reproducibility) of RLQ and to verify if it could be used as specific instrument of evaluation of sleep disorders in children; To check prevalence of sleep disorders in children between three to five years old of both males and females; To establish characteristics of sleep patterns in children between three to five years old and recognize the habits and rituals used by these children to sleep. METHODS: Prospective and observational study for evaluation of internal consistency and reproducibility of RLQ. For the evaluation of internal consistency, 60 children were studied. Age ranged from 3 to 5 years old of both males and females. After medical diagnosis, they were divided in three subgroups: GI- Children with diagnosed sleep disorder; GII - Children without the presence of any sleep disorder; GIII - Children with or without sleep disorders. The results of RLQ were compared with reports from medical neurologist specialized in sleep disorders. For the reproducibility of RLQ, the questionnaire was applied twice to 1021 children between 3 and 5 years old, in public schools in Sao Paulo, during a period that ranged between 14 and 21 days. RESULTS: The questionnaire showed high reproducibility Kappa 0.798 to 1.0, the internal consistency was high for all three groups (080 to 0.86) second coefficient alpha Cronbach. The total sleep time ranged from 10 and 11 hours for children between 3 and 5 years old. The most frequently sleep disorders reported was restlessness during sleep (48.5), snoring (35.8 %), daytime sleepiness (33.2%) and enuresis (21.9 %). Most sleep disorders occurred daily, were more common in females and decreased with age. CONCLUSIONS: The internal consistency and reproducibility of RLQ suggested that this is an adequate instrument for evaluation of sleep disorders in children. The prevalence of sleep disorders varies with gender, age and frequency of this disorder
166

Avaliação como princípio da Gestão da Qualidade Total: testando a confiabilidade interavaliadores de indicadores de qualidade da assistência de enfermagem / Evaluation as the principle of Quality Management: testing the inter- rater reliability of indicators for assessing the quality of nursing care

Vituri, Dagmar Willamowius 05 June 2013 (has links)
A implementação de um sistema de avaliação organizacional por meio de indicadores é imprescindível para uma administração eficiente, na busca da melhoria da qualidade e segurança da assistência, otimização dos recursos, produtividade e satisfação do cliente. A utilização de medidas válidas e fidedignas, no entanto, é condição essencial, pois propicia monitorar a qualidade do cuidado dispensado, subsidia o planejamento de ações corretivas, além de direcionar estratégias e reajuste de metas por meio de ações educativas e de valorização profissional, princípios do Gerenciamento da Qualidade. O objetivo do estudo é testar a confiabilidade interavaliadores de indicadores de qualidade e utilizá-los na avaliação da assistência de enfermagem em hospital público de ensino. Foi desenvolvido em duas etapas: na primeira desenvolveu-se uma pesquisa quantitativa, metodológica, experimental e aplicada, em um hospital terciário público de ensino, que testou a confiabilidade interavaliadores de quinze indicadores de qualidade do cuidado de enfermagem. Na segunda etapa desenvolveu-se uma pesquisa aplicada, descritiva, exploratória, de abordagem quantitativa, do tipo estudo de caso, em duas unidades médico- cirúrgicas da instituição, com um total de 113 leitos, que avaliou a qualidade da assistência de enfermagem por meio da aplicação dos indicadores testados. Os resultados da primeira fase demonstram a fidedignidade dos indicadores, com resultados de Kappa para os indicadores de número 1 a 11 e 15 variando entre 0,956 e 1,000 e Coeficiente de Correlação Interclasse entre 0,951 e 0,992 para os indicadores 12, 13 e 14, o que caracteriza concordância/reprodutibilidade excelente, com p-value menor do que 0,001. Os resultados da aplicação dos indicadores na avaliação da qualidade da assistência mostram que na unidade feminina os menores percentuais de adequação ao padrão relacionam-se aos registros das ações de cuidados, no que tange às identificações (acesso venoso periférico - 44%, equipos - 66%, rótulos de soro - 60%, escala graduada - 33% e sonda gástrica - 58%) e checagens (prescrição de enfermagem - 52%, médica - 75% e registro de sinais vitais - 55%). Na unidade masculina os menores percentuais também se relacionam às identificações (acesso venoso periférico - 58% e sonda gástrica - 71%) e checagens (prescrição de enfermagem - 82%, médica - 86% e registro de sinais vitais - 88%). Com base nos resultados e a partir da aplicação do Ciclo PDCA para Solução de Problemas e ferramenta 5W1H para elaboração do Plano de Ação, a metodologia WebQuest foi proposta como estratégia educativa para enfrentamento dos problemas detectados. Conclui-se que os indicadores testados atendem ao requisito de fidedignidade da medida e os níveis de concordância e confiabilidade obtidos demonstram a relevância deste instrumento para a prática clínica, na avaliação da qualidade da assistência de enfermagem. Nas unidades avaliadas, o desempenho das equipes de enfermagem em relação aos indicadores avaliados se mostrou comprometido, principalmente no que se refere aos registros das ações de cuidados, caracterizando a necessidade de investimentos em capacitação, por meio de formas mais atraentes e estimulantes, que propiciem a busca ativa do conhecimento e que estimulem os servidores a participar das atividades educativas oferecidas pela instituição. / The implementation of an organizational assessment system by means of indicators is essential for an efficient administration in the pursuit of improving the quality and safety of care and optimizing resources, productivity and customer satisfaction. The use of valid and reliable measures, however, is a core condition because it allows for monitoring the quality of the provided care, subsidizes the planning of corrective actions, in addition to directing strategies and readjustment of goals through education and professional development, principles of Quality Management. Thus, this study aims to test the inter-rater reliability of quality indicators and use them in the evaluation of nursing care in a public school hospital. It was developed in two phases: firstly, an applied experimental quantitative methodological research was accomplished in a tertiary public school hospital, in which the inter-rater reliability of fifteen indicators of nursing care quality was tested. In the second phase, an applied descriptive exploratory quantitative research, kind of case study, was accomplished in two medical surgical units of the institution, with a total of 113 beds, which assessed the quality of nursing care through the application of the tested indicators. The results of the first phase show the reliability of the indicators, with Kappa results for the indicators number 1 to 11 and 15 ranging between 0.956 and 1.000 and Intraclass Correlation Coefficient between 0.951 and 0.992 for the indicators 12, 13 and 14, which characterizes excellent concordance/reproducibility, with p-value less than 0.001. The results of the application of the indicators in the assessment of quality care show that in the female unit the lowest percentages of adequacy to the standard relate to the records of care actions, with respect to identification (peripheral venous access - 44%, hoses - 66%, labels of serum - 60%, graduated scale - 33% and gastric hose - 58%) and verification (nursing prescription -52%, medical prescription - 75% and recording vital signs - 55%). In the male unit the lowest percentages also relate to identification (peripheral venous access - 58% and gastric hose - 71%) and verification (nursing prescription - 82%, medical prescription - 86% and recording vital signs - 88%). Based on the results as well as the implementation of the PDCA cycle for Troubleshooting and the 5W1H tool for preparation of the Action Plan, the Web Quest method was proposed as an educational strategy for coping with the problems detected. In conclusion, the indicators tested meet the requirement of reliability of the measures and the levels of agreement and reliability obtained demonstrate the relevance of this instrument in clinical practice for the evaluation of the quality of nursing care. As to the assessed units, the performance of nursing teams in relation to indicators shows insufficient, especially in relation to records of care actions, characterizing the need for investment in more attractive and stimulating training, encouraging the active search for knowledge and stimulating the servers to participate in the educational activities offered by the institution.
167

Estudo qualitativo de um modelo de propagação de dengue / Qualitative study of a dengue disease transmission model

Santos, Bruna Cassol dos 25 July 2016 (has links)
Em epidemiologia matemática, muitos modelos de propagação de doenças infecciosas em populações têm sido analisados matematicamente e aplicados para doenças específicas. Neste trabalho um modelo de propagação de dengue é analisado considerando-se diferentes hipóteses sobre o tamanho da população humana. Mais precisamente, estamos interessados em verificar o impacto das variações populacionais a longo prazo no cálculo do parâmetro Ro e no equilíbrio endêmico. Vamos discutir algumas ideias que nortearam o processo de definição do parâmetro Ro a partir da construção do Operador de Próxima Geração. Através de um estudo qualitativo do modelo matemático, obtivemos que o equilíbrio livre de doença é globalmente assintoticamente estável se Ro é menor ou igual a 1 e instável se Ro>1. Para Ro>1, a estabilidade global do equilíbrio endêmico é provada usando um critério geral para estabilidade orbital de órbitas periódicas associadas a sistemas autônomos não lineares de altas ordens e resultados da teoria de sistemas competitivos para equações diferenciais ordinárias. Também foi desenvolvida uma análise de sensibilidade do Ro e do equilíbrio endêmico com relação aos parâmetros do modelo de propagação. Diversos cenários foram simulados a partir dos índices de sensibilidade obtidos nesta análise. Os resultados demonstram que, de forma geral, o parâmetro Ro e o equilíbrio endêmico apresentam considerável sensibilidade a taxa de picadas do vetor e a taxa de mortalidade do vetor. / In mathematical epidemiology many models of spread of infectious diseases in populations have been analyzed mathematically and applied to specific diseases. In this work a dengue propagation model is analyzed considering different assumptions about the size of the human population. More precisely, we are interested to verify the impact of population long-term variations in the calculation of the parameter Ro and endemic equilibrium. We will discuss some ideas that guided the parameter setting process Ro from the construction of the Next Generation Operator. Through a qualitative study of the mathematical model, we found that the disease-free equilibrium is globally asymptotically stable if Ro is less or equal than 1 and unstable if Ro> 1. For Ro> 1 the global stability of the endemic equilibrium is proved using a general criterion for orbital stability of periodic orbits associated with nonlinear autonomous systems of higher orders and results of the theory of competitive systems for ordinary differential equations. Also a sensitivity analysis of the Ro and the endemic equilibrium with respect to the parameters of the propagation model was developed. Several scenarios were simulated from the sensitivity index obtained in this analysis. The results demonstrate that in general the parameter Ro and the endemic equilibrium are the most sensitive to the vector biting rate and the vector mortality rate.
168

Validação do teste de trilhas - B (trail making test - B) para uso em pacientes brasileiros com câncer em cuidados paliativos / Validation of Trail Making Test B for Brazilian patients with cancer in palliative care

Santos, Juliano dos 12 July 2011 (has links)
Introdução: Prejuízos na atenção, concentração e execução de tarefas, entre outras funções cognitivas, parecem ser frequentes em doentes com câncer e em cuidados paliativos e podem comprometer o cotidiano desses pacientes. No entanto, há poucos estudos sobre o tema e desconhecem-se testes validados para essa população no Brasil. Objetivo: Validar o Teste de Trilhas B (TT-B) para uso em pacientes com câncer em cuidados paliativos. Método: Trata-se de estudo metodológico, de validação de instrumento, que envolveu pacientes (n=94) em tratamento paliativo no Ambulatório de Quimioterapia do Instituto do Câncer do Estado de São Paulo e seus acompanhantes (n=39). Os avaliados realizaram o TT-B e responderam dados sócio-demográficos, sobre a presença e intensidade de dor, de fadiga, sobre a qualidade do sono, ansiedade e depressão, em dois momentos, com intervalo máximo de sete dias. Os doentes também foram caracterizados quanto à doença e tratamento. As validades convergente e divergente foram testadas pela correlação entre o desempenho no TT-B, mensurado pelo tempo para a realização do teste e o número de erros cometidos, com a intensidade da dor, da fadiga, da ansiedade, da depressão e do repouso atribuído ao sono da noite anterior às avaliações. A validade discriminante foi testada pela comparação do TT-B entre doentes e sadios. A estabilidade do TT-B, em doentes e sadios, foi avaliada por meio de teste e reteste. Resultados: Os doentes tinham câncer colo-retal (47,8%), câncer de mama (15,9%), a totalidade apresentava metástase, foram homens (52,1%), com idade média de 53 anos. Para os doentes, o tempo médio de realização do TT-B foi de 147,5 segundos na primeira e 132 segundos na segunda avaliação e o número de erros médio foi de 1 na primeira e 0,8 na segunda avaliação. Para os acompanhantes o tempo de realização do TT-B foi de 127,3 e 110,7 segundos na primeira e segunda avaliação respectivamente e o número de erros foi 0,9 na primeira e 0,6 na segunda avaliação. O instrumento discriminou doentes de sadios em relação ao tempo utilizado para a realização do teste na primeira (p=0,014) e na segunda (p=0,035) avaliação, indicando melhor desempenho para os sadios, mas não em relação ao número de erros. O teste foi estável entre os sadios nas duas avaliações, tanto em relação ao tempo (p=0,071) quanto em relação ao número de erros (p=0,352) e entre os doentes o instrumento foi estável apenas em relação ao número de erros (p=0,913). O TT-B não demonstrou correlações significativas com dor, fadiga, depressão, ansiedade e descanso, o que causou estranheza. Conclusão: O TT-B está em processo de validação. Mostrou-se capaz de discriminar doentes de sadios e foi estável entre os saudáveis. Recomenda-se a continuidade de estudos com amostras maiores e a utilização do TT-B em paralelo a outro instrumento que avalie a função executiva. / Introduction: Impairments in attention, concentration and execution of tasks, among other cognitive functions, seem to be frequent in patients with cancer in palliative care and they can affect patients daily life. However, there are few studies about the theme and to our knowledge there are no validated tests for this population in Brazil. Objective: To validate Trial Making TestB (TMT-B) for assessment of patients with cancer in palliative care. Methods: Methodological study to validate an instrument that involved patients (n=94) in palliative treatment at the Clinic of Chemotherapy of the Instituto do Câncer do Estado de São Paulo and their healthy accompanying person (n=39). Patients were tested on TMT-B and answered demographic data, questions about the presence of pain and intensity, fatigue, quality of sleep, anxiety and depression, in two moments, with maximum interval of seven days. The patients were also characterized according to disease and treatment. The convergent and divergent validities were tested by the correlation between the performance on TMT-B, measured by the amount of time required to complete the task and the number of mistakes, and pain intensity, fatigue, anxiety, depression and the rest attributed to sleep in the previous night before assessments. The discriminate validity was tested by the comparison of TMT-B between patients and healthy accompany persons. The stability of TMT-B, in patients and healthy companions was evaluated through test and re-test. Results: The patients had colorectal cancer (47.8%), followed by breast cancer (15.9%), the totality presented metastasis, most patients were men (52.1%), mean age was 53 years. For patients, mean time required to complete TMT-B was 147.5 seconds in the first and 132 seconds in the second assessments and the mean number of mistakes was 1 in the first and 0.8 in the second assessments. For the healthy accompany person, the time required to complete TMT-B was respectively 127.3 and 110.7 seconds in the first and second assessments and the number of mistakes was 0.9 in the first and 0.6 in the second assessments. The instrument discriminated patients from healthy accompany persons regarding time required to complete the test in the first (p=0.014) and second (p=0.035) assessments, indicating better performance for the healthy ones, but not in relation to the number of mistakes. The test was stable among healthy people in the two assessments regarding time (p=0.071) and number of mistakes (p=0.352); for patients, the instrument was stable only in relation to the number of mistakes (p=0.913). TMT-B did not demonstrate significant correlations with pain, fatigue, depression, anxiety and rest. Conclusion: TMT-B is in validation process. It was able to discriminate between patients and healthy accompany persons and was stable for the healthy ones. Further studies are recommended with larger samples as well as the use of TMT-B in parallel to other instrument that evaluates the executive function.
169

Sistema de classificação de pacientes na especialidade enfermagem psiquiátrica: validação clínica / Patient system classification in psychiatric nursing: clinical validation

Martins, Paula Andrea Shinzato Ferreira 14 March 2007 (has links)
A escassez de publicações a respeito de dimensionamento de pessoal na enfermagem psiquiátrica motivou o desenvolvimento de um Instrumento para Classificar o Nível de Dependência na Enfermagem Psiquiátrica, etapa inicial para o estabelecimento do número ideal de profissionais na Equipe de Enfermagem da especialidade. Para tornar público um Sistema de Classificação de Pacientes, o pesquisador deve garantir a validade de conteúdo e do constructo, além da confiabilidade da ferramenta, permitindo à comunidade científica sua adoção como método, ou mesmo, como material de referência no desenvolvimento de novos modelos. Desta forma, o instrumento foi construído e teve seu conteúdo validado em estudo anterior. Assim, seus objetivos buscaram a validação clínica, por meio de testes de confiabilidade e validade do constructo, além da verificação de sua aplicabilidade na prática gerencial do enfermeiro. Duas amostras foram utilizadas, sendo n=40 pares de instrumentos preenchidos na Fase 1 da coleta de dados e n=100 instrumentos preenchidos na Fase 3 do estudo, tendo sido aplicados cinco diferentes critérios estatísticos, entre eles: o coeficiente Kappa e a correlação de Spearman. O Instrumento para Classificar o Nível de Dependência na Enfermagem Psiquiátrica foi considerado confiável com índices satisfatórios de concordância e o constructo foi validado, determinando o grau de dependência do paciente portador de transtornos mentais, internado aos cuidados da equipe de enfermagem psiquiátrica / The shortage of publications about personnel dimensioning in psychiatric nursing motivated the development of an instrument to Classify the Dependence Level in Psychiatric Nursing, initial stage to the establishment of an ideal number of professionals in the Nursing Crew of the specialty. In order to make public a Patient Classification System, the researcher must guarantee the validity of the content and of the construct, besides the reliability of the tool, allowing to the scientific community its adoption as a method, or even, as a reference material in the development of new models. Thus, the instrument was built and had its content validated in a previous study. Thus, its purposes aimed at the clinical validation by reliability and construct validity tests, besides the checking of its applicability in the managing practice of the nurse. Two samples were used, being n=40 pairs of instruments filled in Stage 1 of data collection and n= 100 instruments filled in Stage 3 of the study, five different statistical criteria were applied, among them, the Kappa coefficient and the Spearman correlation. The instrument to Classify the Dependence Level in Psychiatric Nursing was considered reliable with good indicators of agreement and the construct was validated, determining the degree of dependence of the patient bearing mental disorders, interned under the cares of the psychiatric nursing crew
170

Elaboração e análise da confiabilidade de uma escala para avaliação dos movimentos generalizados em lactentes com riscos para o desenvolvimento neuromotor / Development and analysis of the reliability of a scale for the assessment of general movements in infants with risks for neuromotor development

Aizawa, Carolina Yuri Panvequio 04 February 2016 (has links)
Introdução: O aperfeiçoamento da assistência pré-natal e dos cuidados intensivos neonatais contribuiu para a redução da mortalidade dos recémnascidos (RN) com riscos para alterações do desenvolvimento neuromotor. Apesar destes avanços, a difícil previsão e prevenção de danos neurológicos está associada ao aumento de crianças com problemas graves como a Paralisia Cerebral (PC). Das avaliações disponíveis atualmente, a que possui melhor valor preditivo de danos neurológicos em bebês até os cinco meses de idade é a \"Avaliação Qualitativa dos Movimentos Generalizados (MGs)\" de Prechtl. No entanto, apresenta pouca aderência na prática clínica devido à sua subjetividade e necessidade de treinamento prévio para aplicação. Objetivos: Desenvolver e analisar a confiabilidade de uma escala de avaliação baseada nos MGs caracterizados a partir da avaliação qualitativa de Prechtl em recémnascidos e lactentes com riscos para alterações no desenvolvimento neuromotor. Método: Estudo observacional transversal com a participação de 30 RNs e lactentes com idade compreendida entre 31 semanas pós-menstrual e 17 semanas pós-termo avaliados no Hospital Universitário da USP. Os MGs normais e anormais foram avaliados segundo a análise qualitativa dos MGs de Prechtl seguindo as três fases: pré-termo (n=7), writhing movements (n=13) e fidgety movements (n=10). A escala foi construída baseando-se nestas fases e foram elaboradas duas versões, sendo analisadas as confiabilidades inter e intra-examinador por meio do ICC e do índice de Kappa. A consistência interna da versão final foi analisada através do alfa de Cronbach. Resultados: Foram analisadas duas versões da escala com três diferentes sistemas de pontuação: respostas do tipo \"SIM ou NÃO\"; do tipo \"SEMPRE, ALGUMAS VEZES e NUNCA\"; e \"SEMPRE, QUASE SEMPRE, ALGUMAS VEZES, QUASE NUNCA E NUNCA\". Os resultados mais significativos foram obtidos com as respostas binárias (SIM ou NÃO), sendo que nas fases pré-termo e writhing movements a pontuação máxima é de 32 pontos e na fase dos fidgety movements é de 12 pontos. A análise da confiabilidade da versão final da escala evidenciou concordância excelente tanto para a confiabilidade intra-avaliador (ICCs: 0.914 a 0.999; Kappa: 0.6 a 1 e 0.606 a 1, considerando a escala binária), como para confiabilidade inter-avaliadores (ICCs: 0.871 a 0.966 para avaliação 1; Kappa: 0.682 a 0.775 para avaliação 1, considerando novamente a escala binária). Apenas o índice Kappa neste caso apresentou concordância boa. Os valores de alfa de Cronbach se mostraram de bons a excelentes (0.866 a 0.980). Verificou-se também que os bebês com MGs anormais apresentaram pontuação abaixo de valores entre 20 e 25 na fase pré-termo e dos writhing movements, e abaixo de valores entre 8 e 12 na fase dos fidgety movements. Conclusão: Foi possível desenvolver uma escala capaz de quantificar os MGs, com pontuação capaz de diferenciar MGs normais de anormais, com excelente confiabilidade inter e intra-avaliador e alta consistência interna. A escala apresenta grande relevância clínica e, aliada ao treinamento no método qualitativo, torna-se um instrumento promissor para a detecção precoce de riscos para atraso do desenvolvimento neuromotor e seleção dos RNs e lactentes para acompanhamento e intervenção precoce / Introduction: The technological improvement of neonatal care and intensive care contributed to reduction of preterm newborn (PTNB) mortality. Despite these improvements, is still difficult to predict and prevent neural damage and neurobehavioral impairments, which are associated to higher proportion of children with severe neurological problems, such as Cerebral Palsy (CP). Between all the available methods of babies\' assessment and examination, the Prechtl´s Method of Qualitative Assessment of General Movements (GMs) shows the higher predictive value to neurological damage. Nevertheless, this assessment is not widely used because of its subjectivity and the necessity of training of the examiners. Objective: To develop a quantitative scale based on GMs in the newborn and infant, and to verify its reliability. Method: Crosssectional observational study involving 30 newborns and infants aged between 31 weeks postmenstrual age and 17 weeks post term age assessed at university hospital of University of São Paulo. The normal and abnormal GMs were evaluated based on the Prechtl´s Method of Qualitative Assessment of GMs following the three phases: preterm GMs (n=7), writhing movements (n=13) and fidgety movements (n=10). The scale was developed based on these phases and Kappa and ICC statistics were applied in the reliability analysis (inter- and intra-observer agreement). Cronbach alpha was applied in the internal consistency analysis. Results: Two versions of the scale were analyzed with three different scoring systems: \"YES or NO\"; \"ALWAYS, SOMETIMES and NEVER; \"ALWAYS, OFTEN, SOMETIMES, ALMOST NEVER and NEVER\". The most significant results were obtained with \"YES or NO\" answers. The total score obtained in preterm and writhing movements phases was 32 points and in the fidgety movements phase was 12 points. Considering the assessment with the final version of the scale, high to very high inter- (ICCs 0.871-0.966; Kappa 0.682-0.775 for the first evaluation, considering \"YES or NO\" answers) and intra-observer reliability (ICCs: 0.914-0.999; Kappa: 0.6-1, considering \"YES or NO\" answers) was found. High to very high Cronbach alpha values was also found (0.866-0.980). The infants showed abnormal GMs score below values between 20 and 25 in preterm phase and writhing movements, and below values between 8 and 12 at fidgety movements age. Conclusion: It was possible to develop a scale able to quantify GMs, with scores that can differentiate normal from abnormal GMs, with excellent inter- and intra-observer reliability and internal consistency. The scale has great clinical relevance and, combined with training in qualitative method, it is a promising tool for early detection of risks for delayed neuromotor development and screening of newborns and infants for monitoring and early intervention

Page generated in 0.0657 seconds