271 |
Causes and impact of surface water pollution in Addis Ababa, Ethiopia / Orsaker och effekter av ytvattenföroreningar i Addis Abeba, EtiopienEriksson, Malin, Sigvant, Jonathan January 2019 (has links)
Surface water is globally becoming more and more a scarce resource, and in Addis Ababa the capital of Ethiopia, river water quality has been degraded due to anthropological forcing for many years. Therefore, the study objective was to investigate causes and impact of surface water pollution in Kebena and Great Akaki rivers. The technical aspect of the study focused on analysing the parameters E. coli, phosphate, nitrate and total ammonia nitrogen in 34 different sampling sites in the western part of the Great Akaki catchment. The other aspect was to evaluate authorities’ and companies’ perspective on the water quality, usage and future plans to mitigate further pollution of rivers. Another perspective was to interview households and farmers regarding their view on usage, water quality and health risks. The main finding was a high surface water contamination in both Kebena and Akaki river, throughout the city, mostly from domestic, municipality and industrial wastewater and solid waste. E. coli concentrations exceeded thresholds given by WHO. Concentrations of phosphate and total ammonia nitrogen strongly indicated eutrophication. Nitrate values were lower than expected with no perceived healthrisk. The interview study with authorities, households and farmers indicated irrigation as the main usage. Little to moderate health risks perceived by farm users and high health risks perceived by authorities for farmers were found. Therefore, addressing a stronger collaboration between authorities and the local community is important. In addition, the implementation of mitigation strategies should be strengthened and the stakeholders need to be accountable for their actions. A continued monitoring of pollutants as well as a multi-sectoral approach to solidwaste and wastewater management will help improve the river water quality. / Ytvatten blir globalt allt mer en knapp resurs och i Addis Abeba, huvudstaden i Etiopien, har flodernas vattenkvalitet under många år försämrats på grund av antropogen påverkan. Denna studie syftar till att undersöka orsaker och påverkan på ytvattenföroreningar i floderna Kebena och Akaki. Den tekniska aspekten av studien inkluderar vattenanalyser av parametrarna E.coli, fosfat, nitrat och totalt ammonium kväve som utfördes på 34 olika provtagningsplatser i västra delen av Great Akakis avrinningsområde. Den andra aspekten var att utvärdera myndigheters och företags perspektiv på vattenkvalité, flodvattnets användningsområden och framtida planer för förbättring av föroreningsgraden i floderna. Ett annat perspektiv var att intervjua hushåll och lantbrukare angående deras bild av ytvattenanvändning, om vattenkvaliteten och hälsorisker. Studiens huvudsakliga upptäckt är en genomgående hög föroreningsgrad i stadens flodvatten. Föroreningen består till största del av avlopp och avfall från hushåll, kommuner och industrier. Koncentrationerna av E.coli överskred WHO:s gränsvärden. Halterna av fosfat och totalt ammoniumkväve indikerade övergödning. Nitratvärdena visade lägre halter än förväntat och därmed ingen påvisad hälsorisk. Intervjustudien med myndigheter, hushåll och lantbrukare påvisade att ytvattnet mest används för bevattning av åkermark. Lantbrukarna uppfattade en liten till medelhög hälsorisk med denna användning, medan myndigheter ansåg att lantbrukarna utsattes för en hög risk. Därför är ett starkare samarbete mellan myndigheter och samhället viktigt. Dessutom behöver implementationen av förbättringsåtgärder förbättras och alla aktörer måste göras ansvariga för sina handlingar. En fortsatt övervakning av föroreningar och ett multi-disciplinärt arbetssätt vid avfall- och avloppshantering kommer att vara till hjälp vid förbättring av vattenkvaliteten i floden.
|
272 |
Pesquisa de genes codificadores de enterotoxinas e B-lactamases em Aeromonas jandaei e Aeromas hydrophila provenientes de ambientes aquáticos / Enterotoxins and -lactamases encoding genes investigation in Aeromonas jandaei e Aeromonas hydrophila from aquatic environmentsBalsalobre, Livia Carminato 22 May 2009 (has links)
O gênero Aeromonas está amplamente distribuído em ambientes aquáticos, e estudos recentes incluem o gênero no grupo de patógenos emergentes, devido à sua freqüente associação com infecções locais e sistêmicas em humanos. Este trabalho foi realizado com o objetivo de pesquisar por meio da PCR e confirmar por meio de seqüenciamento, a ocorrência dos genes de virulência act, alt e ast, e resistência cphA, blaIMP, blaVIM, blaSPM-1, blaCTXM, blaTEM e blaSHV, verificando também o perfil de resistência a partir de antibiogramas, e a ocorrência de plasmídios nas cepas estudadas. A partir dos resultados observou-se que das 100 cepas selecionadas inicialmente, 87 pertenciam às espécies A. jandaei (46) e A. hydrophila (41). Dentre as quais pôde-se observar a ocorrência de act, alt e ast, respectivamente em 70,7 por cento (29), 97,6 por cento (40) e 26,8 por cento (11) das cepas de A. hydrophila, e em 4,4 por cento (2), 0 por cento (0) e 32,6 por cento (15) nas cepas de A. jandaei. Os genes blaIMP, blaVIM, blaSPM-1, blaCTX-M, e blaSHV não foram encontrados em nenhuma cepa. O gene cphA foi encontrado em 97,6 por cento (40) e 100 por cento (46) das cepas de A. hydrophila e A. jandaei, respectivamente e o gene blaTEM foi encontrado em 97,6 por cento (40) das cepas de A. hydrophila e em 85 por cento (39) das cepas de A. jandaei. Foi verificada a presença de plasmídio em 10/41 (24,4 por cento) das cepas de A. hydrophila e em 16/46 (34,9 por cento) das cepas de A. jandaei / The genus Aeromonas is widely distributed in aquatic environments, and recent studies include the genus in the emergent pathogens group, due to its frequent association with local and systemic human infections. This work was carried out aiming the investigation and sequencing virulence (act, alt and ast) and resistance (cphA, blaIMP, blaVIM, blaSPM-1, blaCTX-M, blaTEM e blaSHV) genes, also verifying the resistance profile of the strains using antibiograms and the occurrence of plasmids. From the 100 strains analyzed in this study, 87 belonged to A. jandaei (46) and A. hydrophila (41) species. Out of which it was observed the occurrence of act, alt and ast, respectively in 70.7 per cent (29), 97.6 per cent (40) and 26.8 per cent (11) of A. hydrophila strains, and in 4.4 per cent (2), 0 per cent (0) e 32.6 per cent (15) of A. jandaei strains. The genes blaIMP, blaVIM, blaSPM-1, blaCTX-M e blaSHV were not found. CphA gene was found in 97.6 per cent (40) and 100 per cent (46) of A. hydrophila and A. jandaei strains, respectively and blaTEM gene was found in 97.6 per cent (40) of A. hydrophila strains and in 85 per cent (39) of A. jandaei strains. Presence of plasmid was found in 10/41 (24.4 per cent) of A. hydrophila strains and in 16/46 (34,9 per cent) of A. jandaei strains
|
273 |
Desenvolvimento e aplicação de eletrodos compósitos impressos à base de grafite e poliuretana / Development and application of graphite and polyurethane screen-printed composite electrodesSaciloto, Thalita Rocha 07 November 2014 (has links)
Um método de fabricação para eletrodos compósitos impressos à base de grafite e resina poliuretana (EIGPU) foi desenvolvido, iniciando-se pela tinta e processo para a impressão, além da otimização dos parâmetros para garantir a aplicabilidade e maximização da resposta dos mesmos. Os parâmetros otimizados na fabricação da tinta foram a composição de 60% grafite e 40% poliuretana (m/m), a natureza e quantidade de solvente, dimensão do conjunto impresso, quantidade de demãos aplicadas no processo de \"screen-printing\", espessura da máscara adesiva e o tipo de isolante que define os contatos elétricos e a área ativa do eletrodo. Também foi proposto e desenvolvido um procedimento de ativação da superfície do eletrodo, que consiste em uma compressão do compósito, seguido de tratamento eletroquímico da superfície do eletrodo de trabalho, que se mostraram fundamentais para o desempenho adequado do sensor. Os resultados desses estudos inciais foram avaliados usando K3[Fe(CN)6], como sonda eletroquímica. Em seguida, o EIGPU foi avaliado quanto ao seu potencial para determinação de analitos de interesse farmacológico, usando como modelo o paracetamola (APAP) e suas misturasb com cafeína (CAF) em amostras de fármacos (LOD=0,81a, 0,84b(APAP), 1,6b(CAF) µmol L-1); ambiental: Zn2+, Pb2+, Cu2+ e Hg2+ simultaneamente em amostras de etanol combustível (LOD=300, 65, 30, 46 nmol L-1, respectivamente) e biológico: epinefrina (EP) em amostras artificiais de fluido cérebro-espinal sintético (LOD=42,8 e 768 nmol L-1, para DPV e SWV, respectivamente). Para isso, foram usadas Voltametria Cíclica (CV), Voltametria de Pulso Diferencial (DPV), Voltametria de Pulso Diferencial de Redissolução Anódica (DPASV) e Voltametria de Onda Quadrada (SWV). Na determinação dos analitos de interesse ambiental, os eletrodos impressos foram modificados com sílica SBA-15, antes e após organofuncionalização com a espécie benzotiazol-2-tiol. Os compósitos modificados foram preparados substituindo quantidades correspondentes de pó de grafite de modo a obter eletrodos com 5% (m/m) do modificador. Antes de realizar as análises, foram feitas as otimizações dos parâmetros envolvidos em cada técnica escolhida e obtidas as curvas analíticas. Em seguida, o EIGPU foi utilizado na determinação dos analitos nas respectivas matrizes. A quantidade dos analitos presentes nas amostras foi determinada pelo método de adição de padrão, em triplicata. Os resultados foram comparados com aqueles obtidos por Cromatografia Líquida de Alta Eficiência (HPLC) e Espectroscopia de Absorção Atômica (AAS), para as análises farmacêuticas e ambientais, respectivamente. / A method for the fabrication of a graphite polyurethane composite based screen printed electrodes (EIGPU) was proposed by developing a ink and a imprinting procedure after optimizing parameters such as ink composition 60% graphite and 40% polyurethane (m/m), nature and quantity of solvent, dimensions of the electrode set, number of ink layers, deepness of the adhesive mask and nature of the insulating that defines the active electrode area and the electrical contacts. Procedures for activating the electrode surface, by mechanically compressing the ink followed by an electrochemical treatment of the surface were also developed. The results of this phase were evaluated using K3[Fe(CN)6] as an electrochemical probe. Than the EIGPU was evaluated regarding its potentialities for the determination of analytes with pharmacological interest using paracetamola (APAP) and its mixturesb with caffeine (CAF) in pharmaceutical formulations (LOD=0,81a, 0,84b(APAP), 1,6b(CAF) µmol L-1), environmental relevance as metal ions Zn2+, Pb2+, Cu2+ e Hg2+ determined simultaneously in ethanol fuel samples (LOD=300, 65, 30, 46 nmol L-1, respectively) and biologically important as epinephrine (EP) contained in artificial cerebro-spinal fluid. (LOD=42,8 e 768 nmol L-1, for DPV e SWV, respectively).These applications were achieved by means of Cyclic Voltammetry (CV), Differential Pulse Voltammetry (DPV), Square Wave Voltammetry (SWV) and Differential Pulse Anodic Stripping Voltammetry (DPASV). In the determination of the metal ions in ethanol fuel, the electrodes were modified with SBA-15 silica organofunctionalized with benzothiazol-2-thiol. The composities were prepared by substituting corresponding amounts of graphite powder in order to have 5% (m/m) of the modifier in the final device. Before performing the analysis several parameters were optimized for each case for each technique before measuring the analytical curves. After, the EIGPU was used in the determination of the different analytes in the chosen matrices. The amount of analytes present in the samples was determined using addition method in triplicate. The results were compared with those obtained using high performance liquid chromatography (HPLC) and Atomic Absorption Spectrocopy (AAS), as comparision methods.
|
274 |
Desenvolvimento de sensores eletroquímicos e colorimétricos para aplicações em amostras de interesse forense / Development of electrochemical and colorimetric sensors for application in forensic interest samplesAraujo, William Reis de 07 June 2016 (has links)
Esta tese apresenta os estudos e esforços visando ao desenvolvimento de sensores químicos para aplicações diversas na área forense. Foram desenvolvidos métodos eletroanalíticos para detecção e quantificação de alguns compostos comumente encontrados na adulteração de amostras de drogas de abuso (procaína, fenacetina, aminopirina, paracetamol, levamisol), além da cocaína e estudos fundamentais sobre o comportamento eletroquímico desses compostos. Empregaram-se também métodos eletroquímicos para quantificação de compostos tóxicos e perigosos como explosivos (ácido pícrico) e melamina por exemplo. Os trabalhos utilizando sensores eletroquímicos contemplam modificações eletroquímicas das superfícies eletródicas, utilização de sensores com polímeros molecularmentes impressos (MIP) e eletrodos descartáveis em papel utilizando diferentes técnicas voltamétricas e amperométricas, eletrodo disco rotatório (EDR) e microbalança de cristal de quartzo. Além da fabricação de dispositivos analíticos descartáveis em papel empregando detecção eletroquímica utilizou-se também a detecção colorimétrica para quantificação de alguns dos principais adulterantes de amostras de apreensão de cocaína, como procaína e fenacetina, bem como análises e discriminações de compostos explosivos (peroxi e nitro compostos) nessas plataformas portáteis e de baixo custo. Os métodos foram sempre desenvolvidos visando característicos como: facilidade, praticidade, baixo custo e portabilidade para análises diretamente no local de medida com mínima infraestrutura laboratorial. Por fim, são apresentados alguns estudos realizados durante estágio de pesquisa no exterior (Universidade da Califórnia - San Diego (UCSD)) na área de Wearable Sensors, em que foram desenvolvidos métodos para análises de micronutrientes no suor (zinco) e um metabólito (ácido úrico) na saliva usando sensores aplicados diretamente no corpo humano. / This thesis shows studies and efforts to the development of chemical sensors for different applications in the forensic field. Electroanalytical methods were developed for detection and quantification of some compounds (procaine, phenacetin, aminopyrine, acetaminophen, levamisole) commonly found in the drug of abuse adulteration process and cocaine, as well as, fundamental studies about the electrochemical behavior of these compounds. It was also employed electrochemical methods for quantification of hazardous compounds such as explosives (picric acid) and melamine. Analytical methods with electrochemical sensors included electrochemical modification of electrodic surfaces, molecularly imprinted polymers (MIP), and paper disposable electrochemical devices using different voltammetric and amperometric techniques, rotating disc electrode (RDE) and quartz crystal microbalance. In addition to the fabrication of paper disposable analytical devices with electrochemical detection, it was also used the colorimetric detection to quantify some of the major adulterants in cocaine seizure samples, such as procaine and phenacetin, as well as analysis and discrimination of explosive compounds (peroxy and nitro explosives) in these low cost portable platforms. All proposed methods were always developed aming at theses characteristics: ease, convenience, low cost and portability for analysis directly at the measurement site with minimal laboratory infrastructure. Finally, we presented some studies conducted during research internship abroad (University of California - San Diego (UCSD)) in the area of Wearable Sensors, which have been developed methods for micronutrient analysis in sweat (Zn) and a metabolite (Uric Acid) in saliva using sensors applied directly to the human body
|
275 |
Análise de aldeídos de baixa massa molar no ar utilizando eletroforese capilar / Analysis of low molecular-weight aldehydes in air using capillary electrophoresisPereira, Elisabete Alves 07 May 2002 (has links)
Depois dos hidrocarbonetos, os aldeídos de baixa massa molar são os mais abundantes dos gases orgânicos encontrados na atmosfera. Os aldeídos provêm de diversas fontes como as atividades industriais, incompleta combustão de combustível fóssil e biomassa e como resultado de reações fotoquímicas na atmosfera. Os aldeídos são potentes precursores de importantes oxidantes como o nitrato de peroxiacetila (PAN) e ozônio. Eles são reconhecidamente irritante dos olhos e trato respiratório, além de possuir características mutagênicas e carcinogênicas em animais. Considerando o impacto toxicológico e ambiental destes compostos, a prevenção e controle dos aldeídos requerem o uso de novas e versáteis metodologias analíticas. Neste sentido, a eletroforese capilar tem mostrado ser uma técnica alternativa para a análise de aldeídos em amostras ambientais. Este trabalho descreve diferentes metodologias desenvolvidas, em eletroforese capilar, para a separação e análise de aldeídos em amostras de ar (indoor, outdoor) e emissão veicular. As metodologias incluem a separação dos adutos aniônicos bissulfito-aldeído e das hidrazonas aniônicas formadas a partir da reação dos aldeídos com dansilhidrazina (DNSH) e ácido 4-hidrazino benzóico (HBA) por eletroforese capilar em solução livre (free solution capillary electrophoresis, FSCE), bem como a separação das hidrazonas formadas a partir da reação dos aldeídos com 2,4-dinitrofenilhidrazina (DNFH) e 3-metil-2-benzotiazolinona hidrazona (MBTH), utilizando a cromatografia eletrocinética micelar (micellar electrokinetic chromatography, MEKC) . As metodologias foram comparadas em termos de sensibilidade, limite de detecção, procedimento de amostragem, necessidade de purificação dos reagentes derivatizantes e aplicação em amostras de ar. O método do bissulfito apresentou algumas vantagens sobre os métodos estabelecidos na literatura como boa sensibilidade (limite de detecção de 3,4 - 36,9 ng mL-1), rapidez, facilidade de aplicação e pequena manipulação da amostra. A desvantagem é que requer longos tempos de amostragem para a análise de traços (ng mL-1). A metodologia com DNFH apresentou baixa sensibilidade (limite de detecção 0,14 - 2,59 µg mL-1) , necessidade de purificação dos reagentes e solventes. No entanto, o sistema de pré-concentração, na coleta, tornou possível a aplicação do método a amostras de ar indoor. Usando MBTH como agente derivatizante foi possível obter limites de detecção na faixa de 3,1 - 21,1 ng mL-1, análise rápida e pouca manipulação da amostra. O reagente não requer purificação. O principal problema do método é o decréscimo do sinal analítico em função do aumento da cadeia carbônica. O método da DNSH mostrou boa sensibilidade com limites de detecção na faixa de 2,1 - 14,1 ng mL-1 para a detecção UVe 0,96 - 2,6 ng mL-1 para a detecção LIF. O reagente sofre oxidação quando as amostras não são preparadas em acetonitrila ou em outro solvente orgânico. A purificação dos solventes é necessária. O método do HBA mostrou boa sensibilidade com limites de detecção na faixa de 2,7 - 8,8 ng mL-1, rapidez e simplicidade. O solvente deve ser purificado. As hidrazonas sofrem degradação na presença de água e luz. As metodologias estudadas foram aplicadas a amostras reais de emissão veicular, ar indoor e outdoor. Foram verificadas as presenças de formaldeído, acetaldeído e acetona para amostras de ar indoor e outdoor, em concentrações na faixa de ppbv e em amostras veiculares foram encontradas formaldeído e acetaldeído em concentrações na faixa de ppmv. / After the hydrocarbons, the low molecular-weight aldehydes are the most abundant of the organic gases of the atmosphere. The aldehydes are produced from many sources such as industrial activities, incomplete combustion of fossil fuels and biomass or as result of photochemical reactions. Aldehydes are important precursor compounds of photochemical smog and their chemistry has been associated to the generation of harmful oxidants, peroxyacetylnitrate (PAN) and ozone. Aldehydes are recognized irritants of the eyes and respiratory tracts of animais and humans and often carcinogenic and mutagenic characteristics are attributed to them. Because of the toxicological and environmental importance of these compounds, prevention and control of aldehydes have demanded new and versatile analytical methodologies. In this context, capillary electrophoresis has become an interesting alternative technique for environmental analysis. This work describes different CE methodologies developed for the separation and analysis of aldehydes in environmental samples of air (indoors and outdoors) and vehicle exhaust. The methodologies comprise the free solution capillary electrophoresis separation of anionic bissulfite-aldehyde adducts, anionic aldehyde-DNSH derivatives and anionic aldehyde-HBA derivatives as well as the micellar chromatographic separation of aldehyde-DNPH derivatives and aldehyde-MBTH derivatives. These methodologies were contrasted in terms of sensitivity, Iimit of detection, sampling procedure, need for reagent purification and application to air samples. The bissulfite methodology is a novel approach with several advantages over established methods in the literature, such as good sensitivity (range from 3.4 to 36.9 ng mL-1), very easy to implement, speed of analysis and lack of sample manipulation, but it requires long collection volume of air to achieve ng mL-1 detection level. The aldehyde-DNFH derivatives methodology presented poor sensitivity (range from 0.14 to 2.59 µg mL-1). The reagents and solvents must be purified to avoid contamination which will completely interfere with the sample components during analysis. However, the preconcentration achieved during sampling allowed to evaluate aldehyde levels in air samples. Using the MBTH methodology it was possible to obtain a limit of detection range from 3.1 to 21.1 ng mL-1, fast analysis and very little sample manipulation. There is not need for purification of the reagent since it is obtained in grade purity. The main problem with this reaction is that as the length of the aldehyde chain increases, the sensitivity decreases. The aldehyde-DNSH derivatives method presented good sensitivity with a limit of detection range from 2.1 to 14.1 ng mL-1 (UV detection) and 0.96 to 2.6 ng mL-1 (LIF detection). The reagent shows substantial oxidation when the sample is not prepared in acetonitrile or other organic solvent. The aldehyde-HBA derivatives method showed good sensitivity with a limit of detection range from 2.7 to 8.8 ng mL-1, it is fast and simple. However, the solvents must be purified and the derivatives shows substantial degradation in presence of water and light. The developed methodologies were then applied to real samples of indoor, outdoor and automobile emissions. The presence of formaldehyde, acetaldehyde and acetone in indoor and outdoor samples was verified at the low ppbv level and the presence of formaldehyde and acetaldehyde, in automobile samples, was at the ppmv level.
|
276 |
Détection et caractérisation de défauts sous-jacents à la surface dans des bandes d’acier décapées par thermographie infrarouge stimulée / Detection and characterization of subsurface defects in steel strips using Active Infrared ThermographyTaram, Abdoulaye 21 March 2019 (has links)
Dans le contexte actuel d’ouverture des marchés, le contrôle qualité est primordial dans le domaine de la production sidérurgique où qualité se conjugue avec réduction de coûts de fabrication. Ce contrôle peut être décrit comme un ensemble de systèmes déployés pour vérifier et maintenir le niveau de qualité souhaité. Cela implique une inspection minutieuse, accompagnée le plus souvent d’actions correctives. Cette inspection se traduit par l’utilisation, à différentes étapes de la production, d’outils de Contrôle Non-Destructif (CND) pour détecter des défauts. Etant donné que la détection au stade le plus en amont possible de la production est essentielle pour réduire le coût de la qualité et améliorer la production, des systèmes d’inspection à ultrasons sont utilisés au stade du décapage pour détecter certains défauts internes sans ralentir la cadence de production. Toutefois, le besoin de disposer d’une technique de CND sensible aux défauts sub-surfaciques très proches de la surface pouvant se transformer en défauts surfaciques demeure.Parmi les techniques courantes de CND, la thermographie infrarouge stimulée a été identifiée comme ayant un fort potentiel pour la détection des défauts internes très proches de la surface. En outre, cette technique présente des avantages remarquables : elle est sans contact, relativement rapide et adaptable. Son principe est relativement simple : il consiste à créer un transitoire thermique dans un échantillon et à surveiller la réponse de sa surface avec une caméra infrarouge (IR). La présence d’éventuel défaut interne créerait un contraste sous forme de motifs thermiques irréguliers dans la séquence thermique enregistrée. Cette technique, bien qu’attractive n’est pas encore déployée en ligne de production pour détecter des défauts dans les bandes d’aciers décapées. C’est ce qui constitue d’ailleurs l’innovation majeure de cette thèse.La thèse explore les limites théoriques et expérimentales de la thermographie infrarouge stimulée pour la détection de défauts internes dans des métaux. Elle a abouti aux développements d'outils de laboratoire capables de détecter des défauts très proches de la surface, tant dans des configurations statiques qu’en défilement. Ces développements se sont appuyés sur des simulations numériques en 3D qui ont permis d’évaluer le potentiel de la technique ; gagner en expertise ; obtenir des indications pour optimiser et concevoir les dispositifs expérimentaux. Les connaissances acquises à la suite des développements des outils de laboratoire ont montré qu’il est possible d’implémenter la technique directement dans la chaîne de production, particulièrement au stade de décapage où la bande se déplace généralement à 5 m / s. Par conséquent, un système d’inspection a été construit et déployé avec succès pour l’inspection d’une fraction de bande d’acier en milieu industriel. Les résultats obtenus et présentés dans cette thèse sont très encourageants. Des points d’améliorations sont mis en évidence et leur prise en compte permettra d’aboutir sur un système industriel finalisé, robuste et efficient. / In today’s competitive market, the quality control is vital in steelmaking industry where high quality product must pair with cost reduction. This control can be described as a system used for verifying and maintaining a desired level of quality. It implies careful inspection and corrective action if needed. The inspection can be performed with several Non-Destructive Testing (NDT) techniques to detect defects. Since the detection at the earliest possible stage is vital for the reduction of the quality cost, the ultrasonic systems have been used at pickling stage to detect internal defects without slowing down the production paces. However, there is still a need of a sensitive NDT technique to detect near subsurface defects which may turn into surface defects at downstream stages or even worse, at the customers during forming.Amongst the common NDT techniques, Active Infrared Thermography (AIRT) was identified as having a great potential for the detection of near surface internal defects. As an attractive NDT technique, AIRT has remarkable: it is contactless, relatively fast and versatile. Its principle is relatively simple: it consists in heating the sample and monitoring the surface response with an Infrared (IR) camera. The presence of any subsurface defect appears as specific thermal patterns in the recorded thermal sequence. Despite being an attractive technique, AIRT is not deployed yet to detect subsurface defects in steel strip at pickling stage on an industrial production line which is the innovative part of this thesis.The work provided in the thesis investigates the theoretical and experimental limits of AIRT for the detection of subsurface defects in steel samples. First, the investigation led to the development of laboratory tools capable of detecting near subsurface defects in static as well as moving samples. These developments are supported by 3D simulations which allowed evaluating the potential of the technique; gaining comprehensive knowledge; getting guidance for and/or optimize experimental designs. Then, the knowledge developed in laboratory has allowed outlining that the technique can be implemented directly in production line; especially at pickling stage where the strip travels at typically 5 m/s. Therefore, an inspection system was built and successfully implemented for the inspection of a reduced width of the moving strip in industrial environment. The thesis presents encouraging results and some keys identified points that should be considered for the design of full-integrated industrial AIRT inspection system.
|
277 |
Desenvolvimento de métodos espectrofotométricos em condições estacionária e em fluxo para determinação de zinco em amostras biológicas e farmacêuticas / Development of stationary and flow spectrophotometric methods for the determination of zinc in biological and pharmaceutical samplesIvanise Gaubeur 29 June 2001 (has links)
Métodos espectrofotométricos em condições estacionária e em fluxo para determinação de Zn(II) foram desenvolvidos com base na formação do complexo de Zn(II) com di-2-piridil cetona saliciloilhidrazona (DPKSH), em meio de etanol-água 50% (V/V) e pH 4,5. Os complexos de Zn(II) com DPKSH foram caracterizados utilizando diferentes técnicas e as respectivas constantes de formação (βl 1,07x105 e β2 1,05x1010) e absortividades molares, em 376 nm, (εl 1,1x104 e ε2 4,5x104) determinadas. Os parâmetros para o método em condição estacionária foram otimizados e, a seguir, construiu-se a respectiva curva analítica. Obteve-se uma faixa de linearidade (lei de Beer) de (0,0293 a 2,01)x10-5mol. L-1, absortividade molar média (em 376 nm, em meio de etanol-água 50% (V/V) e pH 4,5) de 4,83x104 mol-1.L.cm-1 e limite de detecção igual a 1,24x10-7 mol.L-1 (8,11 µg.L-1). Avaliou-se a interferência de 43 íons. Alguns destes que apresentaram interferência positiva são comuns em preparações farmacêuticas e amostras biológicas, porém tal interferência pode ser facilmente eliminada. Aplicou-se o método desenvolvido à preparações farmacêuticas e amostras biológicas. Comparando-se os resultados com a técnica de absorção atômica com chama, obteve-se grande concordância. O método espectrofotométrico em fluxo foi desenvolvido a partir de alguns parâmetros previamente estudados e estabelecidos. Construiu-se a curva analítica e obteve-se uma faixa de linearidade de (0,332 a 7,04)x 10-5 mol.L-1 e limite de detecção 7,46x10-7 mol.L-1 (48,8 µg.L-1). Aplicou-se o método em preparações farmacêuticas e comparando-se os resultados com a técnica de absorção atômica com chama observou-se grande concordância. Com a finalidade de aplicar o método em fluxo a amostras biológicas, foi acoplada ao sistema uma coluna com resina de troca iônica no lugar da alça de amostragem. Após avaliar alguns parâmetros, construiu-se a curva analítica que apresentou uma faixa de linearidade de (0,126 a 3,15)x10-5 mol.L-1 e limite de detecção 2,12x10-7 mol.L-1 (13,9 µg.L-1). / Spectrophotometric methods in stationary and flow conditions were developed for Zn(II) determination based on the complex formation of Zn(II) with di-2-pyridyl ketone salicyloylhydrazona (DPKSH), in ethanol-water 50% (V/V) medium and pH 4.5. The complexes Zn(II)/DPKSH were characterized by several methods and the respective formation constants (β1 1.07x105 and β2 1.05x1010) and molar absorptivities, in 376 nm, (ε1 1.1x104 and ε2 4.5x104) were determinated. Parameters for the stationary method were optimized and, the analytical curve was obtained. A linear behavior (Beer\'s law) was verified in the range (0.0293 and 2.01)x10-5mol.L-1, the medium molar absorptivity (in 376 nm, ethanol-water 50% (V/V) medium and pH 4.5) and the detection limit are 4.83x104 mol-1.L.cm-1 and 1.24x10-7 mol.L-1 (8.11 ppb), respectively. The interference of 43 ions was evaluated. Some of them that showed present a positive interference are commom in pharmaceutical formulations and biological samples, but such interference could be easily eliminated. The developed method was applied to pharmaceutical formulations and biological samples. The results complied well with atomic absorption (flame atomization) technique. A spectrophotometric method in flow was developed upon some previously established parameters. The analytical curve was determined and a linear range was verified between (0.332 to 7.04)x10-5 mol.L-1, and the detection limit 7.46x10-7 mol.L-1 ( 48.8 µg.L-1). This method was applied to pharmaceutical formulations and the results showed a good agreement with atomic absorption (flame atomization) technique. Aiming at employing the flow method to biological samples an ion-exchange resin column was adapted substituting the sampling handle. After evaluating some parameters the analytical curve was determined and it displayed a linear range of (0.126 to 3.15)x10-5 mol.L-1, and detection limit 2.12x10-7 mol.L-1 (13.9 µg.L-1).
|
278 |
ALGORITMO CO-EVOLUTIVO PARA PARTICIONAMENTO DE DADOS E SELEÇÃO DE VARIÁVEIS EM PROBLEMA DE CALIBRAÇÃO MULTIVARIADA.Ramos, Jorcivan Silva 07 July 2015 (has links)
Made available in DSpace on 2016-08-10T10:40:28Z (GMT). No. of bitstreams: 1
Jorcivan Silva Ramos.pdf: 779202 bytes, checksum: e48a074121bf6a4260fb48b0324ff286 (MD5)
Previous issue date: 2015-07-07 / This paper presents the development of a co-evolutionary genetic algorithm for the
selection of samples from a data set and the selection of variables from the samples
selected in the context of multivariate calibration . Each sample is divided into the
calibration set for the preparation of the model and validating the calibration set of
model. The algorithm selects samples variables with the goal of building the calibration
models. The results show that the data sets selected by the proposed algorithm models
to produce better predictive ability of the models reported in the literature. / Esse trabalho apresenta o desenvolvimento de um algoritmo genético co-evolutivo
para a seleção de amostras a partir de um conjunto de dados e a seleção de variáveis
a partir das amostras selecionadas no contexto da calibração multivariada. Cada
amostra é dividida em conjunto de calibração para a confecção do modelo e conjunto
de validação do modelo de calibração. O algoritmo seleciona amostras e variáveis com
o objetivo de construir modelos de calibração. Os resultados mostram que os
conjuntos de dados selecionados pelo algoritmo proposto produzem modelos com
melhor capacidade preditiva do que os modelos relatados na literatura.
|
279 |
Desenvolvimento de fases monolíticas de sílica híbrida para microextração em sorvente empacotado (MEPS) de fármacos em amostras de plasma e análise por cromatografia líquida acoplada a espectrometria de massas em tandem (LC-MS/MS) / Synthesis of hybrid silica monoliths for microextraction by packed sorbent (MEPS) to determine drugs from plasma samples by liquid chromatography-tandem mass (LC-MS/MS)Souza, Israel Donizéti de 27 July 2015 (has links)
Segundo a Organização Mundial da Saúde (OMS), a esquizofrenia é reconhecida como um transtorno neuropsiquiátrico grave que afeta mais de 21 milhões de pessoas em todo o mundo. Para diminuir os sintomas associados a esta doença, a maioria dos pacientes esquizofrênicos fazem uso concomitantemente de antipsicóticos, antidepressivos, ansiolíticos e anticonvulsivantes. O desenvolvimento de métodos analíticos para a determinação desses fármacos em fluidos biológicos é importante para ajustar as doses administradas, minimizar os efeitos adversos e verificar a anuência do paciente à terapia. A química analítica moderna tem se direcionado para a simplificação, através da miniaturização dos sistemas analíticos. Neste contexto, pode-se destacar a técnica de microextração em sorvente empacotado (MEPS). O desenvolvimento de novas fases extratoras para MEPS, como, os monolitos de sílica híbrida permitem pré-concentração seletiva dos analitos. Neste projeto monolitos de sílica híbrida funcionalizados com grupos aminopropil ou cianopropil foram sintetizados pelo processo sol-gel. Estes monolitos apresentaram estrutura contínua, uniforme e porosa, como evidenciado pelas imagens de microscopia eletrônica de varredura (MEV). As análises de espectroscopia vibracional na região do infravermelho por transformada de Fourier (FTIR) dos monolitos de sílica híbrida exibiram picos facilmente identificáveis, característicos dos grupos cianopropil e aminopropil. Estes monolitos foram avaliados como fase estacionária para a MEPS para a determinação de fármacos em amostras de plasma por cromatografia líquida acoplada a espectrometria de massa em Tandem (LC-MS/MS). As variáveis MEPS (influência do pH na sorção dos analitos, número de ciclos aspirar/dispensar, etapa de limpeza do sorvente e solvente de eluição) foram otimizadas para aumentar a eficiência da extração. Em comparação com a fase de sílica híbrida aminopropil, a fase de sílica híbrida cianopropil apresentou maior capacidade de sorção para os fármacos em estudo. O método desenvolvido, MEPS/LC-MS/MS, empregando a fase extratora de sílica híbrida cianopropil, apresentou linearidade adequada com concentrações que variaram desde o limite inferior de quantificação (0,05-1,00 ng.mL-1) até o limite superior de quantificação (40-10.500 ng.mL-1) com coeficientes de determinação (R2) maiores do que 0,9955. Este método apresentou precisão com coeficientes de variação (CV) inferiores a 14% e exatidão com erro padrão relativo (EPR) de -12 a 14%. O método MEPS/LC-MS/MS foi aplicado com êxito para análise simultânea de cinco antipsicóticos (olanzapina, quetiapina, clozapina, haloperidol e clorpromazina), em combinação com sete antidepressivos (mirtazapina, paroxetina, citalopram, sertralina, imipramina, clomipramina e fluoxetina), dois anticonvulsivantes (carbamazepina e lamotrigina) e dois ansiolíticos (diazepam e clonazepam) em amostras de plasma de pacientes esquizofrênicos para fins de monitorização terapêutica. / According to World Health Organization (WHO), schizophrenia is recognizably a devastating neuropsychiatric disorder that affects more than 21 million people worldwide. To lessen the symptoms associated with the disease, most schizophrenic patients use other classes of drugs such as antidepressants, anxiolytics, and anticonvulsants concomitantly with antipsychotics. Developing analytical methods to quantify these drugs in biological fluids is important in therapeutic drug monitoring (TDM) to adjust doses, minimize adverse effects, and check patient adherence to the therapy. Regarding miniaturization and automation, microextraction by packed sorbent (MEPS) is a promising sample preparation technique. Sample preparation of biological matrixes is an important step in analytical processes: it removes endogenous components from the sample and pre-concentrates trace-level analytes. The development of new phases for MEPS such as the hybrid silica monoliths allows selective pre-concentration of the analytes. The present study reports on the synthesis of two hybrid silica monoliths functionalized with aminopropyl or cyanopropyl groups by the solgel process; evaluates these monoliths as selective stationary phase for MEPS to determine drugs in plasma samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS); and discusses important factors (influence of pH on the sorption of analytes, number of draw/eject cycles, washing step, and elution solvent) related to the optimization of MEPS efficiency. The prepared hybrid silica monoliths consisted of a uniform, porous, and continuous silica monolithic network, as shown by scanning electron microscopy (MEV) images. The Fourier-transform infrared spectroscopy (FTIR) spectra of the hybrid silica monoliths displayed readily identifiable peaks, characteristic of the cyanopropyl and aminopropyl groups. Compared with the aminopropyl hybrid silica phase, the cyanopropyl hybrid silica phase exhibited higher binding capacity for most of the target drugs. The developed method, MEPS/LC-MS/MS, afforded adequate linearity at concentrations ranging from the lower limit of quantification (0.05 to 1.00 ng.mL-1) to the upper limit of quantification (40 to 10500 ng.mL-1); the coefficients of determination (R2) were higher than 0.9955. The precision of the method presented coefficients of variation (CV) lower than 14%; the relative standard error (RSE) of the accuracy ranged from -12 to 14%. The developed MEPS/LC-MS/MS method allowed for simultaneous analysis of five antipsychotics (olanzapine, quetiapine, clozapine, haloperidol, and chlorpromazine) in combination with seven antidepressants (mirtazapine, paroxetine, citalopram, sertraline, imipramine, clomipramine, fluoxetine), two anticonvulsants (carbamazepine and lamotrigine), and two anxiolytics (diazepam and clonazepam) in plasma samples from schizophrenic patients, which should be valuable for TDM purposes.
|
280 |
Padronização e validação analítica do método de extração em fase sólida de levoglucosano em amostras de água de chuva com análises por cromatografia gasosa acoplada à espectrometria de massas / Standardization and validation of analytical method for solid phase extraction of levoglucosan in rainwater samples with analysis by gas chromatography coupled to mass spectrometryFerreira, Marcelo Cardoso 26 October 2012 (has links)
Neste trabalho, o método de extração em fase sólida (SPE) com análises por cromatografia gasosa acoplada à espectrometria de massas (GC-MS) foi desenvolvido para a determinação de levoglucosano em amostras de água de chuva da região de Ribeirão Preto-SP, Brasil. O monossacarídeo levoglucosano foi proposto como um marcador específico para queima de biomassa, uma vez que o mesmo é liberado durante a pirólise da celulose em temperaturas acima de 300ºC. Após a otimização das variáveis SPE, as melhores condições dentre as avaliadas foram as seguintes: cartuchos SPE recheados com a fase extratora quitosana (1,0 g), volume de amostra igual a 5,0 mL, vazão de 1,0 mL min-1, solvente de eluição: metanol (volume igual a 2,5 mL), sem a adição de sal. O método SPE/GC-MS para a determinação de levoglucosano em amostras de chuva apresentou faixa linear no intervalo de concentração de 0,05 µg mL-1 a 0,50 µg mL-1, r 0,9967, exatidão de 95 a 110% e precisão inter ensaios com coeficientes de variação (CV) menores que 15%, exceto para o limite de quantificação (0,05 µg mL-1) o qual apresentou CV inferior a 20%. Segundo as determinações (SPE/GC-MS) de levoglucosano em amostras de água de chuva coletadas no período 03/08/2011 à 09/04/2012, as concentrações médias de levoglucosano na safra de cana-de-açúcar são aproximadamente quatro vezes superior ao período de entressafra. Este fato é justificado pela elevada taxa de queima da palha da cana-de-açúcar na região de Ribeirão Preto-SP no período safra, e consequentemente, maior emissão de material particulado para a atmosfera incluindo levoglucosano, COD, entre outros. / In this work, the method of solid phase extraction (SPE) with gas chromatography - mass spectrometry (GC-MS) analysis was developed for the determination of levoglucosan in rainwater samples collected in the region of Ribeirão Preto-SP, Brazil. The monosaccharide levoglucosan (1,6-Anhydro--D- Glucopyranose) was proposed as a specific marker for biomass burning, since it is released during the pyrolysis of cellulose at temperatures above 300 ° C. After optimization of the SPE variables, the best conditions were found to be as follows: SPE cartridges filled with the extraction phase chitosan (1,0 g), sample volume equal to 5,0 mL, flow rate of 1,0 mL.min-1 and elution with methanol (volume of 2,5 mL) without added salt. The use of the method SPE/GC-MS for to determination of levoglucosan in rainwater samples was in the range of concentration going from 0,05 to 0,50 g.mL-1, r 0,9967. The accuracy was 95-110%, determination of the inter assay precision gare coefficients of variation (CV) less than 15%, except for the limit of quantification (0,05 g.mL-1), for which CV was less than 20%. According to SPE/GC-MS determinations of levoglucosan in rainwater samples collected between 03/08/2011 and 09/04/2012, the average concentrations of this compound found during the harvest of sugar cane were approximately four times those obtained during the off-season. This fact is explained by the high rate of sugar cane burning in Ribeirão Preto-SP during harvest, which culminates in larger emissions of particulate matter to the atmosphere, including levoglucosano and COD, among others.
|
Page generated in 0.0662 seconds