• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1810
  • 563
  • 151
  • 7
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 2539
  • 1138
  • 541
  • 434
  • 364
  • 355
  • 302
  • 264
  • 238
  • 214
  • 205
  • 185
  • 182
  • 179
  • 178
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
451

Evolution de surface lors de la corrosion de magnésium : nouvelles approches analytiques pour comprendre les mécanismes de corrosion et de protection / Surface evolution of corroding magnesium : new analytical approaches to understand corrosion mechanisms and protection strategies

Maltseva, Alina 26 September 2018 (has links)
Les alliages légers (Al, Mg) sont aujourd’hui majoritairement utilisés dans les industries aéronautique, électronique, automobile. Toutefois, la faible résistance à la corrosion et à l’abrasion de ces alliages restreint leur développement à grande échelle. Les nouveaux concepts de protection contre la corrosion des alliages légers se basent non seulement sur un effet barrière par une couche épaisse d'oxyde (PEO) ou peindre, mais surtout sur une protection active à l’aide d’inhibiteurs de corrosion spécifiques. Ces inhibiteurs de corrosion pourraient être libérés "sur demande" et génèrent un phénomène ‘d’auto guérison’. L’utilisation des méthodes d’analyse in situ and ex situ modernes spectroscopiques pourraient permettre de mettre en lumière l’évolution de systèmes aussi complexe et aider à mieux définir les facteurs régulant ces processus. / Nowadays light alloys (Al, Mg) are widely used in a number of areas such as electronics, aeronautic, automotive and construction industries. However, the low corrosion and wear resistance of these alloys hinders application of Al and Mg alloys on a larger scale. The new concepts for corrosion protection of light alloys should include not only barrier protection by a thick oxide layer (PEO) or by paint but also an active protection by specific corrosion inhibitors which can be released “on request” and ensure so-called “self-healing”. Use of in situ and ex situ spectroscopic methods could bring a new view to the evolution of such a complicated system and help to define factors controlling these processes.
452

Étude physico-chimique du silicium amorphe méthylé pour l'électrode négative de batteries Li-ion / Physico-chemical study of methylated amorphous silicon as a negative electrode material for Li-ion batteries

Koo, Bon Min 05 December 2017 (has links)
Des études antérieures ont montré que l'incorporation de groupements méthyles par dépôt assisté par plasma (PECVD) dans des couches minces de silicium améliore leur cyclabilité lors de leur utilisation comme électrodes négatives pour les batteries Li-ion. Dans le cadre de cette thèse, plusieurs approches ont été adoptées pour mieux comprendre les phénomènes impliqués dans ce nouveau matériau lors de cyclages en condition réaliste.Nous avons montré que la spectroscopie infrarouge operando en géométrie de réflexions totales atténuées (ATR-FTIR) apporte des informations quantitatives sur les phénomènes mis en jeu lors de la lithiation et de la délithiation de la couche active. L'augmentation progressive de l'absorbance pendant la première lithiation permet notamment de suivre la formation d’une phase très riche en lithium LizSi qui envahit progressivement le matériau. Nous avons montré que la concentration z du lithium dans cette phase dépend de la teneur en groupements méthyles. Nous avons expliqué ce phénomène par deux effets distincts : (1) la fragilisation du matériau du fait de la diminution du degré de réticulation et de la cohésion. (2) la porosité qui augmente aux teneurs en méthyles plus élevées. Nous avons par ailleurs obtenu par microscopie électronique en transmission une mise en évidence directe de cette porosité à l’échelle nanométrique et de son accroissement avec la teneur en méthyle.Les mesures de spectrométrie de masse à ionisation secondaire à temps de vol (ToF-SIMS) en collaboration avec Chimie ParisTech ont montré que l’invasion du lithium à partir de la phase LizSi vers la zone non-lithiée est un phénomène très lent (correspondant à un coefficient de diffusion D ~10-19 cm2).Nous avons constaté par spectroscopie ATR-FTIR operando et mesures électrochimiques que l'évolution de la couche de passivation (SEI) dépend du taux du cyclage et de la teneur en groupements méthyles lors du premier cycle.Enfin, les phénomènes se produisant lors de l’interruption de la lithiation électrochimique ont été suivis à différents états de charge par spectroscopie ATR-FTIR operando et spectroscopie d'impédance électrochimique (EIS). Nous avons découvert qu'en début de lithiation, une partie du lithium inséré dans la couche repart vers l'électrolyte et contribue à l'augmentation de l'épaisseur de la SEI formée sur l'électrode. / Previous studies showed that the incorporation of methyl groups in silicon thin films obtained by Plasma Enhanced Chemical Vapor Deposition (PECVD) improves their stability as negative electrodes in Li-ion batteries. In this thesis, several approaches have been used to understand phenomena occurring in the so-called "methylated amorphous silicon" during realistic cycling condition.We have shown that infrared spectroscopy operando in attenuated total reflection geometry (ATR-FTIR) provides quantitative information on the phenomena involved during the lithiation and the delithiation of the active material. The gradual increase of the absorbance during the first lithiation makes it possible to follow the formation of a lithium-rich phase LizSi which gradually invades the material. We have shown that the concentration z of lithium in this phase depends on the content of methyl groups. This behavior has been explained by two distinct effects: (1) the weakening of the material due to the methyl-induced lowering of its reticulation degree and cohesion. (2) the increase of the material porosity at high enough methyl content. Transmission Electron Microscopy (TEM) measurements revealed that a porosity is present at the nanometer scale in the active material and increases with methyl content. Time-Of-Flight Secondary Ion Mass Spectroscopy measurements performed at Chimie ParisTech have shown that the lithium invasion of the pristine active material from the lithium-rich phase is an utterly slow phenomenon (corresponding to a diffusion coefficient D ~10-19 cm2).We observed Solid Electrolyte Interphase (SEI) evolution during first cycle depends on cycling rate and methyl content, using operando ATR-FTIR spectroscopy and electrochemical methods.The evolution of the material after interruption of the electrochemical lithiation at several states of charge has been monitored using operando ATR-FTIR spetroscopy and Electrochemical Impedance Spectroscopy (EIS). Those measurements show that part of the lithium initially inserted in the layer returns to the electrolyte during relaxation and contributes to the growth of the SEI.
453

Spectroscopie de luminescence et Raman de complexes des métaux du bloc d à température et pression variable : transitions de phase et changement de l'état émissif

Blanc, Pierre-François 08 1900 (has links)
Ce mémoire se penche sur les propriétés photophysiques de différents complexes métalliques, particulièrement leur changement de structure moléculaire, leur état fondamental ainsi que leur état émissif par spectroscopie Raman et de luminescence. Ces techniques spectroscopiques peuvent être utilisées pour détecter et suivre des changements, comme des transitions de phase structurales. Pour ce mémoire, quatre composés seront étudiés par spectroscopie. Le premier est un composé de nickel(II) ayant un ligand azoture pontant, dont l’agencement spatial change avec une diminution de la température, cette dernière causant un changement dans la susceptibilité magnétique du composé. Les spectres obtenus montrent bel et bien un changement abrupt dans le pic du cisaillement du ligand azoture aux environs de 210 K. Les mesures à pression variable montrent également un changement soudain, entre 1 bar et 1,1 kbar. Le deuxième composé contient deux centres de manganèse(II) ayant chacun une coordination inhabituelle de sept, ce qui n’est pas souvent observé. Il s’avère que la spectroscopie Raman n’est pas assez précise pour mesurer un changement dans ce composé. Tous les déplacements de maxima des bandes mesurés se retrouvaient dans un intervalle de 1 cm-1 ; la résolution de l’appareil limite la confirmation s’il y a bel et bien une transition de phase. Les spectres de luminescence ne montrent pas de changement évident non plus. Le troisième composé est un complexe de platine plan carré qui possède des interactions platine(II)-platine(II), et qui montre un spectre de luminescence. Des complexes similaires ont déjà été étudiés par d’autres membres du groupe de recherche; il s’agit donc de compléter la banque de résultats et de comparer avec les données connues. Les résultats ne montrent aucun déplacement dans la transition, mais un amincissement du pic, ce qui est comparable aux données antérieures. Le quatrième composé est également un complexe de platine(II) plan carré, qui montre un spectre de luminescence. Un composé similaire a déjà été étudié par un étudiant de notre groupe de recherche, en rapportant un changement soudain dans le pic de luminescence. Les spectres mesurés montrent un changement de structure, qui se fait de manière graduelle plutôt que soudainement. Ce mémoire est donc axé sur la spectroscopie Raman et de luminescence à températures et pression variables. Les spectres mesurés, notamment les déplacements des maxima, donnent de l’information sur des changements de structure, de l’état fondamental et de l’état émissif. / This master’s thesis is focused on the vibrational spectroscopy of coordination compounds displaying or undergoes spatial or structural changes as well as variations in their ground state and their emitting state, studied via Raman and luminescence spectroscopy. These spectroscopic techniques can be used to detect and observe various changes, such as phase transitions. In this thesis, four compounds will be studied. The first one is a nickel(II) compound featuring azide bridging ligand, whose spatial arrangement changes by lowering the temperature, causing also a change in the magnetic susceptibility of the compound. The spectra we measured show clearly a sudden change in the scissoring vibration for the azide, at temperatures around 210 K. The variable pressure data we collected also show a sudden change between 1 bar and 1,1 kbar. The second compound contains two manganese(II) centers, both having a coordination number of seven, which is rarely seen for this metal center. Raman spectroscopy isn’t accurate enough to detect any structural changes. Any changes of band maxima were under 1 cm-1, at the limits of the instrument’s resolution. Luminescence graphs do not show anything in particular. The third compound is a square planar platinum(II) complex showing platinum(II)-platinum(II) interactions, influencing its luminescence spectrum. Similar complexes have already been studied by other members of this research group; this research will therefore add results to those we already have, and will be compared to these results. The results don’t show any transition, but the peaks are narrowing at low temperature, a behaviour similar to other systems. The fourth compound is also a square planar platinum(II) complex showing a luminescence spectrum. A similar complex has already been studied by a student in this research group, reporting a sudden shift in the luminescence peak. The spectrum shows indeed a structural change, but this change is gradual instead of sudden. This thesis is focusing on variable temperature and pressure Raman and luminescence spectroscopy. The experimental spectra show information about structural change, fundamental state and emissive state.
454

Influence des nanoparticules d'argent élaborées par procédé plasma sur la conformation de la fibronectine

Martocq, Laurine 02 February 2024 (has links)
L’objectif de ce projet est d’étudier l’influence de nanoparticules d’argent intégrées dans une matrice organosiliciée sur l’organisation de la fibronectine. L’argent étant connu depuis des siècles pour ses propriétés antibactériennes, l’étude de l’adsorption de protéines au contact de ces nanoparticules est essentielle en vue d’une utilisation dans le domaine biomédical. Dans un premier temps, les nanoparticules ont été intégrées dans une matrice organosiliciée, le tout synthétisé par plasma à basse pression. La présence d’argent dans le plasma durant le dépôt a été analysée par spectroscopie d’émission optique. Puis, la fibronectine a été adsorbée sur les surfaces pour étudier l’influence des nanoparticules. Les surfaces ont été caractérisées par différentes techniques notamment par spectroscopie photoélectronique par rayons X pour identifier la présence d’argent et de la fibronectine. La rugosité des surfaces a également été analysée par microscopie à force atomique et des mesures d’angle de contact dynamique ont été réalisées. Enfin, pour quantifier la fibronectine sur les surfaces et pour connaître l’organisation de la protéine, des tests ELISA ont été effectués. / The objective of this project is to study the influence of silver nanoparticles embedded in an organosilicon matrix on the fibronectin organization. Silver is known for its antibacterial properties for several centuries, the study of protein adsorption in contact of these nanoparticles is essential for a use in biomedical field. First, nanoparticles were embedded in an organosilicon matrix, all synthetized by low-pressure plasma. Presence of silver in the plasma during the deposition was analyzed by optical emission spectroscopy. Then, fibronectin was adsorbed on the surfaces to study the influence of silver nanoparticles. Surfaces were characterized by different methods, especially by X-ray photoelectron spectroscopy to identify the presence of silver and fibronectin. Roughness of the surfaces was analyzed by atomic force microscopy and dynamic contact angle measurements were realized. Finally, to quantify the fibronectin adsorbed on the surfaces and to know the protein organization, ELISA tests were performed.
455

Calibration of multivariate predictive models the study of factors influencing the prediction ability of Raman spectroscopy applied to pharmaceutical tablets / Calibration des modèles prédictifs multivariés : étude des facteurs influant sur la prédiction de concentration de comprimés pharmaceutiques avec la spectroscopie Raman

Salvas, Joanny January 2010 (has links)
The use of Process Analytical Technology (PAT) is nowadays well spread throughout the pharmaceutical industry, mostly because they allow gaining useful process insight, better monitoring throughout the manufacturing steps, lowering costs associated with the use of wet-chemistry based testing method, and increasing overall efficiency. Most of the PAT methods are based on multivariate predictive models (MVPM).The calibration of such MVPM is a step crucial to the success of the MVPM-based PAT method development. From what could be gathered of today's practices in MVPM calibration, the current trends are aligned on the mantra"the more the better". This means that best-practices suggest that using more calibration points, with more samples, manufactured as closely as possible to the commercial samples, with more precise measuring reference methods, will lead to a more precise, better performing MVPM-based PAT methods. Obviously, it also leads to a costlier and longer to develop method, thus limiting the potential applications as well as lowering the overall gain to expense ratio of these methods.The aim of this work was to investigate the development protocol of MVPM-based PAT methods in order to identify the factors that were most susceptible to influence the performances of the developed method, with the ultimate goal to propose an optimized protocol. A base case of MVPM-based PAT method was used to perform the assessment: the use of Raman spectra collected from intact pharmaceutical tablets to predict their content in 4 minerals and 1 vitamin. From this development case study, two minerals were chosen to be part of the investigation: one that was in high concentration in the product and one that was in low concentration. Eight (8) factors were identified and tested separately on the two data sets created.The tests were guided by a design of experiment that allowed optimizing the total number of predictive models that needed to be made, all the while retaining sufficient data to allow minimal confusions within second-order factorial interactions. Analysis of results gathered from more than 85 multivariate predictive models allowed identifying factors that had an influence on both type of calibration (high and low raw material concentration).The type of equipment and batch size used for calibration samples manufacturing, as well as the number of points and replicates use (to a certain extent) or the calibration algorithm and reference method did not influence the MVPM accuracy when dealing with highly concentrated raw material. For a low-concentration raw material, the significant factors were the type of equipment and number of calibration points used. In both cases, the distribution of the calibration points along the chosen concentration span showed a significant influence on the method performances. Having identified the factors influencing the MVPM-based PAT method, an optimized protocol for future development could be proposed. Using this alternate approach should reduce the required invested man- and lab-time by approximately 30 %. A 31 % reduction in development-related costs is also expected. These results can be achieved with a manageable accuracy decrease varying between 0 and less than 2 % (absolute values), depending on the type of raw material concentration monitored. This study fills a gap in the published literature. No extensive and comprehensive studies had been made, to the author's knowledge, regarding the overall development process of such MVPM-based methods. Several hints for future research and developments are also proposed to follow-up with this project.
456

Optimisation de l'utilisation d'un spectromètre proche infrarouge pour le suivi de l'humidité d'une poudre pharmaceutique lors du séchage dans un lit fluidisé

Demers, Anne-Marie January 2011 (has links)
Le contrôle de la qualité est une étape critique lors de la fabrication de produits pharmaceutiques. Pour accomplir cette tâche, différentes méthodes de laboratoire peuvent être utilisées, mais celles-ci sont habituellement coûteuses et exigent beaucoup de temps. Une alternative suggérée par l'agence réglementaire Food and Drug Administration est l'utilisation d'outils permettant l'analyse en continu, dont entre autres les outils spectroscopiques comme le proche infrarouge par exemple. Une des applications de cette technologie est le suivi de l'humidité d'une poudre pharmaceutique lors de son séchage dans un lit fluidisé. Une sonde à réflectance, qui est attachée au spectromètre, est insérée dans le bol du lit fluidisé et des spectres sont acquis tout au long du procédé. L'interprétation des spectres obtenus nécessite toutefois l'application de l'analyse multivariée et l'utilisation de plusieurs tests statistiques. Une courbe de calibration peut ainsi être construite et être utilisée au lieu des tests réalisés au laboratoire. Néanmoins, les paramètres critiques du spectromètre peuvent influencer la performance de la courbe de calibration bâtie. Par ailleurs, les articles publiés sur le sujet d'intérêt mentionnent que l'emplacement de la sonde, c'est-à-dire son angle et sa hauteur dans le bol, est critique pour l'obtention d'une acquisition spectrale de qualité. Or, aucun article n'a été publié sur la détermination de cet emplacement optimal et aussi sur le type d'embout à utiliser pour s'assurer d'une bonne lecture spectrale. Tout d'abord, des courbes de calibration ont été construites pour deux produits différents, soient un supplément vitaminé et un anti-inflammatoire. La méthodologie utilisée pour ces modélisations chimiométriques était innovatrice, car seulement des échantillons provenant de l'usine étaient utilisés et les spectres acquis avec le spectromètre étaient répliqués pour chaque échantillon collecté. Par la suite, un embout permettant une acquisition spectrale de qualité a été conçu et le nombre moyen de scans/spectre a été déterminé. En ayant fixé ces deux paramètres, la performance de la courbe de calibration construite pour le supplément vitaminé a été évaluée dans le lit fluidisé dans un environnement de production. Enfin, des plans d'expériences réalisés dans le lit fluidisé au laboratoire avec les deux produits ont permis d'évaluer l'effet des paramètres critiques du spectromètre sur les performances des courbes de calibration. Les tests statistiques effectués sur les deux courbes de calibration montrent de bonnes corrélations entre les prédictions par le spectromètre et les valeurs de référence. Par ailleurs, les essais réalisés dans un environnement de production ont démontré qu'un embout comportant une cavité permettant à la poudre de se stabiliser ainsi qu'un faible nombre de scans/spectre assurent une acquisition spectrale de qualité. Uniquement la courbe de calibration construite pour le supplément vitaminé a été évaluée dans un environnement de production ; le modèle chimiométrique réussit à bien prédire la fin de séchage. Enfin, les conclusions obtenues suite aux plans d'expériences réalisés dans le lit fluidisé au laboratoire ne peuvent pas être généralisées à différents produits. Il a aussi été démontré qu'il est difficile d'acquérir des spectres en mode dynamique et d'interpréter les résultats associés aux réplicas d'essais. Des travaux futurs sont suggérés pour investiguer certaines questions suscitées par cette recherche.
457

What can optical spectroscopy contribute to understanding protein dynamics ?

Byrdin, Martin 28 September 2010 (has links) (PDF)
The short answer to the title question is: "a lot". It was transient absorption spectroscopy on geminate recombination in myoglobin that led Hans Frauenfelder to constructing his picture of protein's hierarchical energy landscape [1]. And even before that (in 1973), Joseph Lakowicz and Gregorio Weber at UIUC used quenching of tryptophan fluorescence by oxygen diffusing to solvent-inaccessible protein regions to conclude that "proteins, in general, undergo rapid structural fluctuations on the nanosecond time scale " [2]. The not-so-short answer is that the present text is written at a point where, after a decade of applying transient absorption spectroscopy to understand light induced electron transfer in a variety of enzymes, I am about to change the angle of attack and ask how these techniques and enzymes could be of help to solve some problems that are addressed in the IBS environment, namely protein dynamics, both structural and functional. It is for this reason that the answer will have to be delayed to the third and final part of this opus, "future", that deals with the perspectives. Meanwhile, the first part, "past", will be dedicated to showing on the example of the "paradigm" enzyme -DNA photolyase (the yellow egg hereunder)-, what transient absorption spectroscopy is capable of and the middle part, "present" dresses a short review into various experimental approaches currently used to obtain insight into protein dynamics. In the final section, I will delineate ways how optical spectroscopy could interact with projects existing or emerging in the protein dynamics community at IBS and thus contribute elements of an answer to the title question.
458

Approche expérimentale et théorique de la diffusion Raman exaltée : résonance des plasmons de surface et effet de pointe

Le Nader, Victor 26 October 2010 (has links) (PDF)
Ce travail de thèse s'articule autour des phénomènes d'exaltation de la diffusion Raman grâce aux propriétés optiques des métaux nobles (Or et Argent). Des expériences de Spectroscopie Raman Exaltée de Surface (SERS : Surface Enhanced Raman Spectroscopy) et de Spectroscopie Raman Exaltée par sonde locale (TERS : Tip Enhanced Raman Spectroscopy) ont permis l'exploration des ces phénomènes. Le premier volet de ce travail a consisté en la préparation de substrats « SERS-actifs » et en l'analyse de leurs pouvoir exaltant. Trois types de substrats ont été élaborés au laboratoire afin d'étudier les paramètres d'influence (structuration de la surface, longueur d'onde et polarisation de la lumière incidente, nature du métal, etc...). Le second volet du travail a été consacré à la mise en place d'un dispositif TERS. La conception des pointes métalliques a fait l'objet d'une attention particulière. De plus, un module a été élaboré afin d'associer un système de nano-positionnement de la pointe à un Raman confoncal commercial. Ce module a aussi été conçu pour permettre de focaliser le faisceau laser à l'extrémité de la nano-sonde métallique. La conception des outils ainsi que la compréhension des résultats expérimentaux sont corrélés à une analyse numérique. Les sources électromagnétiques (plasmons de surface et effet de pointe) de l'amplification de la diffusion Raman sont étudiées avec l'appui de simulations numériques par la méthode des éléments finis. Enfin les aspects chimiques des phénomènes d'exaltation sont abordés par DFT (Density Functiunal Theory).
459

Imagerie spectrale pour l'étude de structures profondes par tomographie optique diffusive de fluorescence

Montcuquet, Anne-Sophie 17 December 2010 (has links) (PDF)
L'imagerie optique de fluorescence permet de localiser des cibles biologiques comme des tumeurs, marquées par des fluorophores. Pour des applications au diagnostic chez l'Homme où l'épaisseur des tissus atteint plusieurs centimètres, la détection parasite de l'autofluorescence naturelle des tissus compromet la détection de la fluorescence d'intérêt et son élimination est la condition sine qua non d'une localisation correcte de la tumeur. L'objet de cette thèse a été l'étude spectrale de l'auto fluorescence des tissus et la mise au point d'une méthode de séparation de spectres aveugle permettant de supprimer sa contribution des mesures. La Factorisation en Matrices Non-négatives a été privilégiée, et de nouveaux algorithmes ont été proposés et testés sur données réelles. Nous avons démontré les performances de notre méthode dans l'amélioration de la détection des marqueurs et la reconstruction de la position de la tumeur en tomographie optique diffuse de fluorescence.
460

Recherche et Caractérisation des Propriétés Physiques et Chimiques des Compagnons de Faible Masse, Naines Brunes et Planètes Géantes, à l'aide d'observations à Haut Contraste et à Haute Résolution Angulaire

Bonnefoy, Mickaël 22 October 2010 (has links) (PDF)
Mon travail de thèse se place dans le contexte dynamique de la détection directe des compagnons de faible masse (naines brunes, planètes extrasolaires) dans le but de caractériser leurs propriétés physiques et chimiques et de comprendre leurs mécanismes de formation et d'évolution. Cette recherche requiert l'emploi de techniques d'observations à haut contraste et à haute résolution angulaire pour résoudre l'environnement proche des étoiles et ne pas être limité par leur flux. Dans ce cadre, j'ai eu la chance de participer à des campagnes d'observations pour tenter de détecter de nouvelles sources. J'ai élaboré un ensemble d'outils de traitement et d'analyse des données pour extraire les spectres et les flux des objets dans des bandes photométriques. Enfin, j'ai utilisé ces informations pour étudier les propriétés physiques (rayon, masse, âge) et atmosphériques (composition, température effective, gravité de surface) de ces objets. La première partie de ce manuscrit se focalise sur la détection par imagerie des compagnons de faible masse jeunes (< 100 millions d'années). Je décris un ensemble d'outils de réduction et d'analyse, spécifiques à la technique d'imagerie angulaire différentielle, que j'ai mis en place. Ces outils ont été utilisés sur des données provenant de l'instrument NaCo situé au Very Large Telescope (Chili). Ils ont permis de re-détecter la planète extrasolaire β Pictoris b. Ce compagnon est le plus proche de son étoile de toutes les exoplanètes détectées directement. Cette découverte fournit la preuve directe que des planètes géantes se forment en moins de 12 millions d'années à l'intérieur de disques. Je présente enfin l'analyse complémentaire que j'ai mené pour initier la caractérisation de cet objet particulier. Le second volet de mon travail, présenté dans la deuxième partie du manuscrit, est axé sur la détermination des propriétés spectroscopiques dans le proche infrarouge (1.1-2.5 µm) des objets de faible masse jeunes. Ce travail à débuté par l'optimisation et le développement d'outils de traitement et d'analyse des données du spectrographe intégral de champ SINFONI assisté par optique adaptative. Les efforts déployés ont permis d'analyser le spectre du compagnon naine brune/exoplanète AB Pic b. Ce travail s'est poursuivi par la construction d'une bibliothèque de spectres d'objets jeunes. Cette bibliothèque fournie un ensemble de spectres de référence pour l'étude des compagnons détectés. Elle apporte des contraintes inédites sur les dernières générations de modèles d'atmosphère froids. Enfin, j'ai tiré parti de l'expérience acquise sur les instruments NaCo et SINFONI pour caractériser le système binaire TWA 22AB qui pourrait calibrer les modèles d'évolution des objets de faible masse.

Page generated in 0.3361 seconds