• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 286
  • 237
  • 100
  • 30
  • 11
  • 9
  • 8
  • 6
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 800
  • 356
  • 232
  • 177
  • 157
  • 114
  • 109
  • 109
  • 104
  • 94
  • 85
  • 84
  • 82
  • 78
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
601

Síntese e caracterização de eletrocatalisadores Pt/C, PtAu/C e PtAuBi/C pelo método da redução via feixe de elétrons para oxidação direta de metanol e etanol / Síntese e caracterização de eletrocatalisadores Pt/C, PtAu/C e PtAuBi/C pelo método da redução via feixe de elétrons para oxidação direta de metanol e etanol

CARDOSO, ELISANGELA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:26Z (GMT). No. of bitstreams: 0 / As células a combustível do tipo PEM (Próton Exchange Membrane) alimentadas diretamente por hidrogênio são consideradas as mais promissoras para a geração de energia elétrica, entretanto o uso de hidrogênio como combustível nestas células apresenta ainda alguns inconvenientes operacionais e de infra-estrutura, o que dificulta o seu uso. Assim, nos últimos anos, uma célula a combustível que utiliza um álcool diretamente como combustível (DAFC - Direct Alcohol Fuel Cell) tem despertado bastante interesse, particularmente aquelas que são alimentadas pelos combustíveis metanol ou etanol, pois apresentam várias vantagens, como por exemplo, a não necessidade de estocar hidrogênio ou gerá-lo através da reforma de hidrocarbonetos.Porém, células que utilizam diretamente metanol como combustível, apresentam correntes relativamente baixas e a oxidação completa do etanol é dificultado pela quebra da ligação CC e também há a formação de intermediários fortemente adsorvidos no eletrocatalisador de platina, como o monóxido de carbono (COads), resultando em baixos potenciais operacionais na célula.Para minimizar o efeito causado pelos venenos catalíticos faz-se necessária a adição de outros metais na composição do eletrodo de Pt. Tais metais devem atuar na reação fornecendo sítios para a adsorção de espécies que contenham oxigênio (OH ou H2O), em potenciais inferiores ao potencial de adsorção de OH na Pt.Este trabalho apresenta estudos da reação de eletro-oxidação destes álcoois, nos meios ácido e alcalino, sobre os eletrocatalisadores Pt/C, PtAu/C e PtAuBi/C, utilizando o método da redução via feixe de elétrons. Os eletrocatalisadores PtAuBi/C foram preparados com diferentes composições atômicas a fim de se avaliar o efeito da adição de bismuto. Os experimentos foram caracterizados por voltametria cíclica e cronoamperometria, utilizando a técnica do eletrodo de camada fina porosa, obtendo informações em relação às atividades dos catalisadores, perfis eletroquímicos e suas estabilidades em relação ao tempo de operação. Os eletrodepósitos foram examinados usando análise de energia dispersiva de raios-X (EDX) e microscopia eletrônica de varredura (MEV) a fim de determinar a composição de fases, o tamanho e a distribuição das nanopartículas metálicas no suporte. Os resultados eletroquímicos mostraram para oxidação eletroquímica de metanol, no meio alcalino, que o catalisador de PtAu/C apresentou melhor atividade eletrocatalítica e, no meio ácido, o catalisador Pt/C foi mais efetivo com relação às demais formulações preparadas e os eletrocatalisadores PtAuBi/C apresentaram-se pouco efetivos. No caso da oxidação do etanol, os dados eletroquímicos mostraram que, no meio ácido os catalisadores PtAu e Pt/C possuem comportamentos similares e os catalisadores PtAuBi/C demonstram baixa atividade. No meio alcalino, o sistema PtAuBi/C obteve melhor desempenho em relação aos demais catalisadores, obtendo maiores valores de correntes à baixos potenciais. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
602

Determinação de parabenos em antitranspirantes empregando voltametria sob eletrodo de diamante e cromatografia liquida de alta eficiencia / Determination of parabens in antiperspirants using voltammetry on boron-doped diamond electrodes and high-performance liquid chromatography

Carreira, Francieli Cristiani 29 February 2008 (has links)
Orientador: Susanne Rath / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-11T06:57:29Z (GMT). No. of bitstreams: 1 Carreira_FrancieliCristiani_M.pdf: 773670 bytes, checksum: 6d050c7c60c651787ea726a2bdbbbd40 (MD5) Previous issue date: 2008 / Resumo: Ésteres do ácido p¿hidróxibenzóico, tais como metilparabeno (MePa), etilparabeno (EtPa) e propilparabeno (PrPa) são conservantes químicos amplamente empregados em cosméticos, fármacos e alimentos. Uma vez que estes compostos estão associados a alergias, dermatites e propriedades estrogênicas, faz-se necessário avaliar a concentração destas substâncias nas diferentes matrizes. A ANVISA estabelece para cosméticos uma concentração máxima de parabenos totais de 0,8 % m/m. Os objetivos deste trabalho foram avaliar o comportamento eletroquímico dos parabenos no eletrodo de diamante dopado com boro e o desenvolvimento de um método voltamétrico para a determinação de MePa, EtPa e PrPa em antitranspirantes tipo roll on. As condições otimizadas do método voltamétrico foram: técnica voltametria cíclica; eletrólito suporte, tampão fosfato 0,1 mol L, pH 7,0; velocidade de varredura, 50 mV s. Nestas condições, os parabenos sofrem oxidação em 0,85 V versus Ag/AgCl, KCl sat. O processo é irreversível e controlado por difusão. Para a quantificação dos parabenos totais, as amostras foram preparadas usando a extração em fase sólida e na quantificação foi usada a hidroquinona como padrão interno. Para avaliar a exatidão do método proposto, os resultados obtidos na análise de amostras de antitranspirantes pelo método voltamétrico proposto foram comparados com àqueles obtido por cromatografia líquida de alta eficiência. Todas as amostras analisadas (12 amostras de fabricantes diferentes) apresentaram um teor de parabenos totais menores do que 0,38 % m/m. Destas, 6 amostras não especificaram corretamente a presença dos parabenos nos rótulos / Abstract: Esters of p-hydroxybenzoic acid, as methylparaben (MePa), ethylparaben (EtPa) and propylparaben (PrPa) have been widely used as chemical preservatives in cosmetics, drugs, foods, and others. As these compounds are linked with allergies, dermatitis and estrogenic properties, it is necessary to control the concentration of these substances in the different matrices. The ANVISA establish a maximum concentration of 0.8 % w/w of total parabens in cosmetics. The aims of this work were the study of the electrochemical behavior of parabens on the boron-doped diamond electrode and the development of a voltammetric method for the determination of parabens in antiperspirants (roll-on). The optimized voltammetric conditions established were: cyclic voltammetry; supporting electrolyte, phosphate buffer 0.1 mol L, pH 7.0; scan rate, 50 mV s. At these conditions, the parabens undergo oxidation at 0.85 V versus Ag/AgCl, KCl sat. The process is irreversible and diffusion controlled. The sample preparation was carried out using solid phase extraction and the total paraben quantitation was done using hydroquinone as internal standard. The accuracy of the method was evaluated through comparison of results obtained from analyses of antiperspirants by the proposed voltammetric method with those obtained by high performance liquid chromatography. All samples analyzed (12 samples of different manufactures) presented a content of total parabens lower than 0.38 % w/w. The presence of parabens in six samples was not correctly specified at the label / Mestrado / Quimica Analitica / Mestre em Química
603

Sintese e caracterização do antimoniato de meglumina usado no tratamento de leishmaniose e desenvolvimento de metodos para especialiação de antimonio / Synthesis and characterization of meglumine antimoniate and develpment of methods for antimony speciation

Doretto, Keity Margareth, 19-- 25 July 2008 (has links)
Orientador: Susanne Rath / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-11T15:44:21Z (GMT). No. of bitstreams: 1 Doretto_KeityMargareth_M.pdf: 885846 bytes, checksum: 58deaa5a75fe44417e40247d90966df2 (MD5) Previous issue date: 2008 / Compostos orgânicos a base de antimônio ainda são empregados no tratamento de leishmaniose e, no Brasil, o fármaco de primeira escolha continua sendo o antimoniato de N-metilglucamina (ANMG). Este fármaco a base de Sb(V) não possui estrutura química definida, tendo sido relatados, entre outros, a presença de Sb(III) como contaminantes. O objetivo deste trabalho foi a síntese e caracterização de ANMG e o desenvolvimento e validação de métodos analíticos para a especiação de antimônio (Sb(III) e Sb(V)) no ANMG, usando a voltametria de onda quadrada e a cromatografia líquida de alta eficiência associada a um detector de arranjo de diodos (HPLC-DAD). A determinação de Sb(III) no ANMG foi realizada por voltametria de onda quadrada, usando o eletrodo de gota pendente de mercúrio (HMDE) e ácido clorídrico 2,0 mol L como eletrólito suporte. Para a determinação de Sb(V) foi avaliado o uso da voltametria adsortiva com redissolução catódica por onda quadrada usando o ácido cloranílico (AC) como agente complexante. No entanto, o método não apresentou seletividade para a determinação de Sb(V) no ANMG na presença de Sb(III) e N-metilglucamina. Sendo assim, foi desenvolvido e validado um método HPLC-DAD para a especiação de Sb(V) no ANMG, através do complexo formado com AC. A separação foi realizada em uma coluna de fase reversa octadecil híbrida e uma fase móvel composta de solução aquosa de ácido fosfórico pH 2 e metanol por eluição com gradiente e quantificação em 310 nm. Todos os métodos desenvolvidos foram validados mediante avaliação dos seguintes parâmetros: faixa linear, linearidade, sensibilidade, seletividade, precisão intra-ensaio e inter-ensaio, limites de detecção e quantificação e exatidão. O produto de síntese, obtido a partir da reação entre Sb(V) N-metilglucamina, foi caracterizado por análise elementar e espectrometria de massas em tandem por interface de ionização por electrospray (ESI-MS/MS Q-ToF). Foi confirmada a coexistência de várias espécies de antimônio em solução, assim foi possível realizar a especiação de antimônio, quanto ao estado de oxidação, por essa técnica / Organic compounds containing antimony are still employed in the treatment of leishmaniasis and, in Brazil, the drug of choice, continues to be N-methylglucamine antimoniate (ANMG). This drug containing Sb(V) doesn¿t possess a defined chemical structure, and several contaminants Sb(III), among others, has been reported. The aim of this work was the synthesis and characterization of ANMG and the development and validation of analytical methods for antimony speciation (Sb(III) and Sb(V)) in ANMG, using square wave voltammetry (SWV) and high performance liquid chromatography coupled to a diode array detector (HPLC-DAD). The determination of Sb(III) in ANMG was accomplished by SWV, using the hanging mercury drop electrode (HMDE) and 2.0 mol L hydrochloric acid as a supporting electrolyte. For the determination of Sb(V) the use of square wave adsorptive stripping cathodic voltammetry was evaluated, using the HMDE and chloranilic acid (AC) as a complexing agent. However, the method didn¿t present selectivity for the determination of Sb(V) in ANMG in the presence of Sb(III) and N-methylglucamine. Due to this fact, a HPLC-DAD method was developed and validated for the speciation of Sb(V) in ANMG by formation of a compound with AC. The separation was carried out with a reverse phase octadecyl hybrid column with a mobile phase composed of an aqueous phosphoric solution, pH 2 and methanol over gradient elution and quantification at 310 nm. All of the development methods were validated by evaluation of the following parameters: linear range, linearity, sensitivity, selectivity, intra-assay and inter-assay precisions, limit of detection, limit of quantification and accuracy. The product obtained by synthesis using Sb(V) and N-methylglucamine as reagents, was characterized by elementary analysis and by electrospray ionization tandem mass spectrometry (ESI-MS/MS Q-ToF). The presence of several species containing antimony in solution was confirmed and antimony speciation, in relation to the oxidation state, was carried out / Mestrado / Quimica Analitica / Mestre em Química
604

Métodos eletroanalíticos e ensaios de atividade antioxidante no controle de qualidade de mel

Rezende, Stefani Garcia 30 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-12-04T08:42:21Z No. of bitstreams: 2 Dissertação - Stefani Garcia Rezende - 2015.pdf: 1241735 bytes, checksum: dafaf794ccbc058198ef0f2dd475ae74 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-12-04T08:43:59Z (GMT) No. of bitstreams: 2 Dissertação - Stefani Garcia Rezende - 2015.pdf: 1241735 bytes, checksum: dafaf794ccbc058198ef0f2dd475ae74 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-12-04T08:43:59Z (GMT). No. of bitstreams: 2 Dissertação - Stefani Garcia Rezende - 2015.pdf: 1241735 bytes, checksum: dafaf794ccbc058198ef0f2dd475ae74 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-03-30 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The honey is a concentrated source of nutrients, it is used by animals and exploited as a natural resource for homes since antiquity. Many studies have tried to characterize the honey and its quality, but the complex natural process of production, involve that any research is not able to obtain fully satisfactory results. In this work 24 samples. Were studied 24 samples from honey producing regions located around Goiania - GO and some foreign samples (Portugual, USA and New Zelândias), those donated by the Beekeeping Association of the State of Goiás and these purchased in specialty stores in their respective countries . The physical and chemical tests as indicative of deterioration, hydroxymethylfurfural (HMF) and diastase activity (AD), followed parameters proposed by Normative Instruction N. 11/2000 of the Ministry of Agriculture, Livestock and Supply (MAPA). The antioxidant components analysis was used for traditional spectroscopic methods Folin-Ciocalteu (FC), Ferric Reducing Antioxidant Potential (FRAP), 2,2-diphenyl-1-picryl-hydrazyl (DPPH●); and electroanalytical calculated from the oxidation peaks voltammetric differential pulse (DPV) by Electrochemical Index (EI). While mid-infrared method (IR) and methods of multivariate statistical analysis were used for identification and classification of honey from different floral sources and/or regions. As for the deterioration analysis test (HMF and AD) 50% of the samples applied in these tests, for the control of physical and chemical quality, were at odds with the Normative Instruction N. 11/2000 of MAPA. All samples showed the presence of antioxidant compounds exposed by methods FC, FRAP, DPPH● and EI; and the method of FRAP was the one closest to the EI and the DPPH● was inversely proportional to EI, which may conclude that the electroanalytical by DPV is suitable for analysis of antioxidant compounds in honey. The infrared results coupled with chemometric tool, principal component analysis (PCA) and hierarchical cluster analysis (HCA), were not satisfactory for sample groups of the same floral origin and/or region, but suggested trend in results. / O mel é uma fonte concentrada de alimento, é usada pelos animais e aproveitada como recurso natural pelos homens desde a antiguidade. Muitos são os estudos que trataram de caracterizar os méis e sua qualidade, mas o complexo processo de produção natural pelas abelhas faz que nenhuma pesquisa obtenha resultados plenamente satisfatórios. Neste trabalho foram estudadas 24 amostras provenientes de regiões produtoras de mel localizadas no entorno de Goiânia – GO e algumas amostras estrangeiras (Portugal, Estados Unidos e Nova Zelândia). Os testes físico-químicos empregados com indicativos de deterioração foram (de acordo com a Instrução Normativa nº 11/2000 do Ministério da Agricultura, Pecuária e Abastecimento - MAPA): o método do hidroximetilfurfural (HMF) e atividade diastásica (AD). Alem da avaliação da qualidade, foi analisada a capacidade antioxidante mediante: métodos espectrofotométricos tradicionais (Folin-Ciocalteau - FC, Ferric Reducing Antioxidant Potential - FRAP; e 2,2-difenil-1-picril-hidrazil - DPPH●); e métodos eletroanalíticos (Índice Eletroquímico - IE, calculado a partir dos picos de oxidação da voltametria de pulso diferencial - DPV). Os resultados obtidos por os diferentes métodos foram tratados usando técnicas de estatística descritiva e quimiometría como a análise de componentes principais (PCA) ou análise hierárquica (HCA), com a finalidade de classificar e identificar as méis a partir das fontes florais e/ou regiões. Os resultado das análises de deterioração (HMF e AD), 50% das amostras estavam em desacordo com a citada Norma. Respeito à atividade antioxidante, em todas as amostras, contrastou-se uma correlação entre os diferentes métodos de analises (FC, FRAP, DPPH● e IE). O método do FRAP foi o que mais se aproximou do IE e o DPPH● foi inversamente proporcional ao IE, o que pode concluir que a técnica eletroanalítica DPV é satisfatória para análise de compostos antioxidantes em mel.
605

Desenvolvimento de métodos eletroanalíticos para avaliação da capacidade antioxidante / Development and evaluation of electro analytical methods of antioxidant capacity

Benjamin, Stephen Rathinaraj 28 March 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2016-05-19T12:27:41Z No. of bitstreams: 2 Dissertação - Stephen Rathinaraj Benjamin - 2016.pdf: 9705883 bytes, checksum: 750508198f2865e073cf36b649344178 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: on 2016-05-19T12:31:22Z (GMT) / Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2016-05-19T12:48:30Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Stephen Rathinaraj Benjamin - 2016.pdf: 9705883 bytes, checksum: 750508198f2865e073cf36b649344178 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-05-19T13:11:59Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Stephen Rathinaraj Benjamin - 2016.pdf: 9705883 bytes, checksum: 750508198f2865e073cf36b649344178 (MD5) / Made available in DSpace on 2016-05-19T13:11:59Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação - Stephen Rathinaraj Benjamin - 2016.pdf: 9705883 bytes, checksum: 750508198f2865e073cf36b649344178 (MD5) Previous issue date: 2016-03-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study investigated the antioxidant activity using biosensors based on carbon paste electrode (CPE) modified with crude extract of laccase (Pycnoporus sanguineus, activity 2019 U L-1) in different compositions. The biosensor consists of carbon nanotubes activated with DNA (CPEL-DNA: CN) showed the best sensitivity level, 0.0549 μA / μM and 1.2 uM detection limit (LOD) in the concentration range of 20-140 μM of rutin. This biosensor showed excellent stability over 10 days and reproducibility (RSD <5%). This biosensor was used to determine the total amount of phenol in coffee samples (expressed by the equivalent rutin) using electroanalytical technique. For the evaluation of its detection capability, the results were compared with other electroanalytical techniques using analytical basis as samples of commercial coffee from different countries. The CPL-DNA: CN was used to determine the total amount of phenol in coffee samples (expressed by the equivalent rutin). Thus, it was possible to propose the CPL as an analytical tool for the detection of phenols. In this research, we developed several studies using different CPE to investigate the antioxidant natural product profile such as coffee samples, dry extracts of acerola, obtained by cyclic voltammetry (CV),) differential pulse voltammetry (DPV) and square wave voltammetry (SWV), which allowed to conclude classes of antioxidants present in the samples. The quantitative determination of these compounds was performed using the standard addition method by differential pulse voltammetry and electrochemical index (EI) has been proposed for estimating the oxidizing potential between different samples. Carbon paste electrode was also investigated using the different quality control samples commercialized produced from acerola employing DPV for the quantification of ascorbic acid (AA) in all samples, where the limit of detection (LOD) and limit of quantification (LOQ) was 0.31 and 0.96 μM and with excellent recovery between 97.4 to 102.2% The DPPH tests were used to compare the antioxidant activity in coffee and acerola samples. The Folin-Ciocalteu method was used to estimate the antioxidant activity of rutin from coffee samples. These methods proposed had advantages such as simplicity of sample preparation and the speed of the analysis of antioxidant capacity. / Neste trabalho foram realizados ensaios de atividade antioxidante em amostras de acerola, café, bem como de outros extratos secos de frutos vermelhos, empregando-se eletrodos convencionais de pasta de carbono (EPC), bem como biossensores de EPC modificados com extrato bruto de lacase (EPCL), partindo de Pycnoporus sanguineus (atividade 2019 U L-1) em diferentes composições com e sem uso de agentes modificadores, visando avaliar melhor sistema. Para além consolidar o uso de métodos eletroanalíticos, i.e. voltametria cíclica (VC), voltametria de onda quadrada (VOQ) e pulso diferencial (VDP), na análise de produtos naturais, seja para avaliar perfil antioxidante, seja para inferir sobre classes de antioxidantes presentes nas amostras, pode-se neste estudo avaliar o papel de diferentes agentes modificadores. O biossensor constituído de nanotubos de carbono ativado com DNA (EPCL-DNA) apresentou o melhor nível de sensibilidade 0,0549 μA/μM e um limite de detecção (LOD) de 1,2 μM no intervalo de concentração de 20-140 μM de rutina. Além disso, o biossensor mostrou ter uma excelente estabilidade ao longo de 10 dias e reprodutibilidade (RSD < 5%). Para a avaliação da sua capacidade de detecção, os resultados obtidos foram comparados com outras técnicas eletroanalíticas usando como base analítica amostras do café comercial de diferentes países. O EPCL-DNA foi empregado para determinar a quantidade de fenol total nas amostras de café (expressa pelo equivalente de rutina). Com isso, foi possível propor os EPCL como ferramenta analítica para a detecção dos fenóis. A determinação quantitativa desses compostos foi realizada através da construção de curvas de calibração para VPD e o índice eletroquímico foi proposto para estimar o potencial antioxidante entre diferentes amostras. Também foi investigado o uso de EPC para o controle de qualidade de diferentes produtos obtidos a partir da acerola, empregando VPD para a quantificação de ácido ascórbico (AA) em todas as amostras, onde os limites de detecção (LD) e o Limite de quantificação (LQ) foi de 0,31 e 0,96 μM respectivamente e com uma excelente taxa de recuperação entre 97,4-102,2%. Os ensaios de DPPH foram utilizados para comparar a atividade antioxidante nas amostras de café e acerola. O método de Folin-Ciocalteu foi usado para estimar a atividade antioxidante da rutina nas amostras de café. Pode concluir-se que os métodos propostos apresentaram vantagens, como a simplicidade na preparação das amostras e a rapidez do ensaio da capacidade antioxidante.
606

Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense / Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.

Matheus Manoel Teles de Menezes 14 November 2014 (has links)
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito. / Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.
607

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Laura Siqueira de Oliveira 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
608

Desenvolvimento de métodos voltamétricos para a quantificação de LSD utilizando-se o eletrodo de pasta de carbono modificado com complexo de base de Schiff / Development of voltammetric methods for the quantification of LSD using a carbon paste electrode modified by a Schiff base complex

Maria Fernanda Muzetti Ribeiro 29 October 2015 (has links)
Nos últimos anos, vários métodos eletroanalíticos foram desenvolvidos a fim de tornarem mais práticas e acessíveis às análises químicas de substâncias entorpecentes realizadas pela polícia científica. Com a sensibilidade e seletividade compatíveis com as dos métodos instrumentais convencionais, é a portabilidade da técnica eletroanalítica que se sobressai e tem apresentado grande potencial para tais aplicações. O uso de complexos metálicos com as bases de Schiff como modificadores do eletrodo de trabalho, tornou ainda mais promissora a utilização destes métodos para a detecção e quantificação de entorpecentes. Os eletrodos de pasta de carbono também contribuem para a praticidade da eletroanalítica, uma vez que são produzidos de forma simples e barata. Desta forma, neste projeto foram desenvolvidos métodos voltamétricos para a quantificação da dietilamida do ácido lisérgico (LSD), utilizando-se o eletrodo de pasta de carbono modificado com o complexo [UO2(Ac-ophen)]·H2O. A aplicação do KCl como eletrólito suporte, em solução aquosa, diferencia estes métodos do encontrado na literatura. Nas análises, foram empregadas as técnicas de voltametria cíclica, onda quadrada e de pulso diferencial. A linearidade no aumento da corrente frente às variações da concentração do LSD possibilitou a obtenção das curvas analíticas com desvio padrão e limites de detecção e quantificação de 2,45, 0,62 e 1,02 mol L-1, respectivamente, como melhores resultados. As análises de recuperação das amostras, 103 e 108%, demostra a possibilidade da utilização destas no âmbito forense. / The development of electroanalytical methods for forensic science has been growing in recent years by the fact of their practicality and low cost. Once sensibility and selectivity values are compatible to conventional methods, as chromatography and spectrometry, the portability of this system consists on interesting advantages. The simple modification of the carbon paste working electrode with Schiff bases complexes became even more promising to use this method for the detection and quantification of narcotics. The carbon paste electrode itself contributes for the practicality of the analyses, once it is made of simple carbon powder, which can be disposable. This project aimed to develop voltammetric methods for the quantification of the lysergic acid diethylamide (LSD) using a carbon paste electrode modified with the complex [UO2(Ac-ophen)]·H2O. The use of aqueous solution of KCl as supporting electrolyte characterizes a less pollutant methodology, differently of other methods that still use toxic solvents The combination of the differential pulse and square wave voltammetries with the modified carbon paste was crucial for the detection of trace levels of the LSD. The linear response in various concentrations of LSD results on analytical curves with standard deviation, detection, and quantification limits of 2,45, 0,62, 1,02 mol L-1, respectively. And the recovery values of 103 and 108 % indicates the possibility of using this method in the forensic science
609

Avaliação ambiental de exposição a fumos metálicos em fundições / Environmental assessment of exposure to metallic fumes in foundries

Fabiana da Silva Felix 17 June 2004 (has links)
A Universidade de São Paulo (Instituto de Química e Faculdade de Ciências Farmacêuticas) e FUNDACENTRO têm desenvolvido um projeto nos pólos de fabricação de peças de torneiras e registros de Loanda/PR, visando a avaliação do ambiente de trabalho. Considerando as etapas do processo de fundição de latão para a confecção dos produtos, há a presença de fumos metálicos, provenientes da fundição e vazamento, que podem acarretar na intoxicação dos trabalhadores e, conseqüentemente, faz-se necessária a avaliação do risco ocupacional. Esta avaliação consiste da caracterização das partículas através da determinação de seus constituintes em massa por volume de ardo ambiente de trabalho. A concentração para particulados é expressa em &#181;g m-3. Para isso, foi aplicada metodologia específica e reconhecida do National Institute of Organization Safety (NIOSH), a qual recomenda a utilização de espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) para a determinação de As, Cd, Mn, Ni e Pb em amostras de ar. Foi proposta uma alternativa utilizando a voltametria de acumulação com redissolução anódica com eletrodo de gota pendente de mercúrio para a determinação de Cd e Pb, além da voltametria adsortiva com redissolução catódica com o mesmo eletrodo para Ni e voltametria de redissolução catódica com eletrodo de diamante dopado com boro para Mn, sendo que utilizou-se onda quadrada para a obtenção de todos os voltamogramas. De acordo com os resultados obtidos, foram propostas alterações tecnológicas no processo e adequação dos equipamentos de proteção no intuito de proteger a saúde e o bem estar dos trabalhadores, bem como evitar danos ao meio ambiente. / The Universidade de São Paulo, Instituto de Química e Faculdade de Ciências Farmacêuticas (University of São Paulo, Institute of Chemistry and Pharmaceutical Sciences College) and FUNDACENTRO have developed a project at the manufacturing facilities of stopcocks and faucet parts in Loanda/PR, aiming the evaluation of workplaces. Considering the stages of the brass foundry process in manufacturing those products, there are metallic fumes, originating from metal melting and pouring, which can result in human intoxication and, therefore, it is necessary to make an assessment of the occupational exposure. This assessment consists of collecting the particulate, measuring the mass of the contaminant, and then calculating the concentration by dividing the mass by the volume of sampled air. For particulates, concentration is expressed as &#181;g m-3. For this assessment, it was applied a specific and recognized method of the National Institute of Organization Safety Health (NIOSH) which recommends the use of the technique of inductively coupled plasma optical emission spectrometry (ICP OES) to determine As, Cd, Mn, Ni and Pb in air samples. It was proposed an alternative method using the anodic stripping voltammetry with hanging mercury drop electrode (HMDE) to determine Cd and Pb, in addition to cathodic adsorptive stripping voltammetry with HMDE to determine Ni and cathodic stripping voltammetry with boron-doped diamond electrode to determine Mn. For these procedures were used square wave voltammetry to record all the voltammograms. According to the results of this work, we proposed technological changes in the production process and the adequacy of protection equipment in order to protect the health and well-being of workers, as well as to avoid damages to the environment.
610

Desenvolvimento, comparação e aplicação forense de sistemas de injeção em banho e injeção em fluxo, com detecção voltamétrica de chumbo em eletrodo de mercúrio / Development, comparison and forensic application of injection and flow injection systems with voltammetric detection of lead in mercury electrode

Adriana De Donato 10 August 2001 (has links)
Para determinar baixas concentrações de chumbo, oriundo de resíduos de disparo de armas de fogo, aplicou-se a voltametria de redissolução anódica, ASV, com pulso diferencial, PD, para detecção do metal em eletrodo de gota pendente de mercúrio, EGPM. A etapa de redução se dava a -0,6 V vs. Ag/AgCl, durante 25s, com imediata varredura até -0,3V vs. Ag/AgCl. O pico de reoxidação do chumbo surgia a -0,42V vs. Ag/AgCl. A injeção de amostras foi bastante facilitada pela aplicação do sistema de análise por injeção em banho, BIA onde um pequeno volume de amostra é injetado, com o auxílio de um micropipetador automático, diretamente sobre um detector imerso em um volume várias vezes maior que aquele da amostra. Com o intuito de estender a técnica ao EGPM comercial, um adaptador simples, em forma de J, foi desenvolvido e aplicado, o qual dirige o fluxo descendente do micropipetador para cima, diretamente sobre a gota de mercúrio. Foi dada a presença de chumbo, da ordem de 1 ppm, quando se amestrava as mãos encontro de voluntários, do Instituto de Criminalística da Polícia Científica do Estado de São Paulo, com tiras de fita crepe antes e depois de um conjunto de disparos. A extração do chumbo foi feita através da agitação de cada tira de fita crepe, apoiada em tela de Nylon&#174;, com uma mistura de clorofórmio e HCl 0,1 M, com a fase aquosa sendo levada a posterior análise. Outros métodos de coleta também foram testados. Nota-se, também, que é possível determinar o mesmo analito em sistemas de injeção em fluxo, após desoxigenação do eletrólito suporte. Com o uso da técnica de pulso reverso, a desoxigenação pode se tornar desnecessária. / In order to determine low concentrations of lead, originated from gunshot residues, anodic stripping voltammetry, ASV, with differential pulse, DP, was applied to detect the metal in a hanging mercury drop electrode, HMDE. The reduction step was done at -0.6 V vs. Ag/AgCl, for 25s, followed by the immediate scan up to -0.3V vs. Ag/AgCl. The reoxidation current peak appeared at -0.42V vs. Ag/AgCl. The injection of samples was greatly facilitated by the application of the batch injection analysis system, BIA, where a small sample volume is injected, with the aid of an automatic micropipettor, directly onto the detector, which is immersed in a volume many times larger than the sample. Aiming the application of the technique with commercial HMDE, a simple J-shaped adapter was developed and applied, which directs upwards the descending flow of the micropipettor, rightly over the mercury drop surface. The presence of lead was observed at around 1 ppm, after sampling the hands of volunteers, from the Institute of Criminalistics of the Scientific Police of São Paulo State, with strips of adhesive tapes before and after a set of gunshots. Lead extraction was performed shaking each strip, over a Nylon&#174; screen, in a mixture containing chloroform and HCl 0.lM, with the posterior analysis of the aqueous phase. Other collection methods were also tried. It is also possible to determine the same analyte in a flow injection system, after the deoxygenation of the supporting electrolyte. With the aid of the reverse pulse technique, the deoxygenation may become unnecessary.

Page generated in 0.0715 seconds