Spelling suggestions: "subject:"boron doped diamond"" "subject:"boron doped oiamond""
71 |
Avalia??o do comportamento eletroqu?mico da cotinina no eletrodo de diamante dopado com boro e estudos para sua determina??o em saliva por amperometria pulsada em fluxoAlecrim, Morgana Fernandes January 2016 (has links)
Data de aprova??o ausente. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2016-12-20T14:07:54Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-01-17T18:51:10Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5) / Made available in DSpace on 2017-01-17T18:51:10Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
morgana_fernandes_alecrim.pdf: 1686041 bytes, checksum: c2250fb532be684ddef616d3424c8dc0 (MD5)
Previous issue date: 2016 / A Cotinina (CO) ? o principal metab?lito da nicotina, sendo utilizada como biomarcador para monitorar a exposi??o de um indiv?duo ao tabaco. Os m?todos comumente utilizados para a determina??o desse composto em amostras biol?gicas s?o baseados na cromatografia l?quida, os quais, em geral, s?o dispendiosos e requerem tratamentos tediosos dessas amostras. Dessa maneira, torna-se necess?rio o desenvolvimento de novos m?todos mais simples e r?pidos para determina??o da CO. Nesse contexto, o presente trabalho prop?e o uso eletrodo de diamante dopado com boro (BDD) para detec??o e caracteriza??o eletroqu?mica da CO por t?cnicas voltam?tricas, bem como sua quantifica??o em amostras de saliva por meio da amperometria de m?ltiplos pulsos (MPA) em sistema de an?lise por inje??o em fluxo (FIA). Em meio de tamp?o fosfato a 0,1 mol L-1 (pH 7) a CO apresentou dois processos eletroqu?micos, um an?dico em +1,8 V e um cat?dico em -1,2 V (vs. Ag/ AgCl), sendo o segundo dependente do primeiro e ambos de car?ter irrevers?vel. Foi verificado que o processo de transporte de massas para a oxida??o da CO ? preferencialmente difusional sobre o eletrodo de BDD e que 2 el?trons e pr?tons est?o envolvidos na rea??o eletroqu?mica. O coeficiente de difus?o calculado para a CO foi de 5,7 x 10 -2 cm2 s-1. Para determina??o da CO em saliva, MPA foi utilizada aplicando-se 4 pulsos de potencial, sendo: (1) em +1,8 V/ 400 ms potencial gerador (EG) para oxida??o da CO; (2) em -1,0 V/ 500 ms potencial para elimina??o de interferentes na amostra de saliva, (3) em -1,2 V/ 30 ms potencial coletor para reduzir e quantificar a CO gerada pelo EG; (4) em -145/ 300 ms potencial para limpeza da superf?cie do BDD. A freq??ncia anal?tica te?rica foi obtida de 24 determina??es por hora com uma vaz?o otimizada em 3,0 mL min-1 e a al?a de amostragem de 300 ?L no sistema FIA. Al?m disso, um baixo desvio padr?o relativo de 1,46% foi obtido para 10 determina??es consecutivas de CO 10 ?mol L-1. Nessas condi??es, foi obtida uma faixa linear de 0,5 a 100 ?mol L-1 (R= 0,998) com limite de detec??o calculado em 0,18 ?mol L-1 para CO. Os estudos de adi??o e recupera??o da CO em amostras de saliva foram de 96,77%, Portanto, mediante a caracteriza??o eletroqu?mica e os estudos por FIA-MPA usando eletrodo de BDD, este trabalho apresenta uma alternativa simples, r?pida e de baixo custo para monitoramento do grau de exposi??o ao tabaco pela determina??o da CO em amostras de saliva. / Disserta??o (Mestrado) ? Programa de P?s-gradua??o em Ci?ncias Farmac?uticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, [2016]. / The Cotinine (CO) is the major metabolite of the nicotine an disused as a biomarker to monitor the exposure of an individual to tobacco. The methods commonly used for CO determination in biological samples are based on liquid chromatography, which generally are expensive and require tedious treatments of the samples. Thus, it becomes necessary to develop simpler and faster methods for determining CO. In this context, this paper proposes the use boron-doped diamond (BDD) film electrode for the detection and electrochemical characterization of CO by voltammetric techniques and, CO quantification in saliva samples by multiple-pulse amperometry (MPA) in analysis by flow injection (FIA) system. In phosphate buffer solution 0.1 mol L-1 (pH 7), the CO presented two electrochemical processes, one anodic at + 1.8V and one cathode at -1.2V (vs. Ag/ AgCl), with the second process dependent on the first and both irreversible process. It was found that CO electrochemical processes are controlled by diffusion and, two-protons and two-electrons are involved in the oxidation reaction. The diffusion coefficients calculated for CO was 5.7 x 10 -2 cm2 s-1. In determination of CO in saliva samples, the MPA detection was used applying four potential pulses: (1) at +1.8V/ 400ms ? generator potential pulse (EG) for oxidation of CO; (2) at-1.0V/500ms - potential for remove possible interferents, (3) at - 1.2V/30ms - collector potential pulse potential for reduction of the product generated by EG and CO quantification; (4) at-14.5V/ 300 ms- potential pulse for cleaning BDD electrode. The proposed method obtained a theoretical analytical frequency with 24 determinations per hour by FIA system in flow rate of 3.0 ml min-1 and sample loop of 300?L. Furthermore, a low relative standard deviation of 1.46% was obtained for 10 measurements of CO 10 ?mol L-1. Under these conditions, A good linear range from 0.5 to 100 ?mol L-1 (R = 0.998) was obtained with a detection limit estimated at 0.18 ?mol L-1 for CO. The addition and recovery studies of CO in saliva samples were 96.77%. Therefore, this work presents, by the first time, an electrochemical characterization of the CO and a method simple, fast and low cost for monitoring the degree of exposure to tobacco by CO determination in saliva samples using FIA-MPA technique.
|
72 |
Uso do método do padrão interno em sistemas FIA e BIA e determinação simultânea de diclofenaco e codeína em formulações farmacêuticas por amperometria de múltiplos pulsos / Use of the internal standard method in FIA and BIA systems and determination of diclofenac and codeine in pharmaceutical formulations by multiple pulse amperometryGimenes, Denise Tofanello 25 July 2013 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The present thesis demonstrates, for the first time, the possibility of using of the
internal standard method in FIA or BIA systems with amperometric detection. The
method allows to obtain accurate results in the presence of fluctuations in the system
parameters (injected volume, dispensing rate, ionic strength and accidental insertion of
air bubbles) and in the presence of contamination and/or gradual passivation of the
working electrode surface. Methods for determination of diclofenac (DCF) using FIA
with amperometric detection and simultaneous determination of DCF and codeine (CO)
by BIA with amperometric detection have also been developed.
The internal standard method was implemented in the flow injection analysis with
multiple pulse amperometric detection (FIA-MPA) system by applying a sequence of
potential pulses of the working electrode as a function of time. The analyte (+0.80
V/300ms) and internal standard (-0.05 V/400ms) were detected selectively, one at each
potential pulse. Significant improvements were obtained in the accuracy of the system
when the results before and after normalization (using the internal standard method),
were compared. The following errors were calculated, respectively, before and after
normalization of the results using the internal standard method. Change in flow rate
from 3.0 to 1.0 ml min-1 (-57% e < 1%); volume injection from 300 to 100 μL (-63%
and 3%); ionic strength from 0.60 to 0.77 mol L-1 (-44 and 0,2%) and before and after
the introduction of air bubbles into the system (-9,6% and 1,7%). A significant
improvement was also obtained in the correlation coefficient of the calibration curve in
the presence of problems of passivation or contamination of the working electrode. The correlation coefficient was calculated, respectively, as 0,975 and 0,998, before and after
the normalization of the results by the IS method.
The internal standard method was also applied to correct errors derived from the
injection procedure (dispensing rate and injected volume) in batch injection analysis
systems (BIA) with amperometric detection when disposable syringes were used. The
results obtained before and after normalization of the results by the IS method were the
following, respectively: repeatability test (RSD = 6.4 and 1.8%; n = 8), correlation
coefficients (R=0.954 and 0.997) and errors obtained in analysis of synthetic samples (E
= 9.4 ± 1.5 and 3.5 ± 0.7%; n = 8).
The determination of DCF by FIA-MPA was implemented by applying two
potential pulses to the BDD electrode using H2SO4 0.1 mol L-1 as supporting
electrolyte: (i) + 1.2 V / 50 ms for oxidation and quantification of DCF, and (ii) 0.0 V /
50 ms for constant electrochemical cleaning of the electrode surface. The system
showed good stability (RSD = 1.0%, n = 10) and high analytical frequency (135
injections h-1). The method showed a linear response between 5 and 50 μmol L-1 and the
detection and quantification limits were as 0.14 and 0.46 mmol L-1, respectively. The
proposed method was applied to determine of DCF in pharmaceutical formulations and
the obtained results were similar to those obtained by HPLC with a confidence level of
95%.
The simultaneous determination of DCF and CO was performed using the
following potential pulses: (i) +1.1 V / 50 ms: oxidation and quantification of DCF; (ii)
+1.4 V / 50 ms: simultaneous oxidation of DCF and CO, (iii) 0.0 V / 200 ms: for
constant electrochemical cleaning of the BDD electrode. The oxidation current from CO
was obtained by the difference between currents detected at 1.4 and 1.1 V by using a correction factor. The system showed good stability (RSD = 0.9% and 1.1 for DCF and
CO respectively, n = 10) and high analytical frequency (~ 300 injections h-1). The
method showed a linear response between 10 and 50 μmol L-1 for DCF and 7.1 and 35.7
μmol L-1 for CO. The LQ and LD were calculated, respectively, at 1.1 and 3.7 μmol L-1,
for DCF and 1.0 and 3.3 mol L-1 for CO. The proposed method was applied for
simultaneous determination of DCF and CO in pharmaceutical formulations and the
obtained results were similar to those obtained by HPLC with a confidence level of
95%.
Keywords: Multiple pulse amperometry, FIA, BIA, internal standard, simultaneous
analysis, boron doped diamond (BDD), codeine, diclofenac. / Esta tese apresenta, pela primeira vez, a possibilidade de usar o método do padrão
interno em sistemas FIA ou BIA com detecção amperométrica. O método permite a
obtenção de resultados precisos na presença de flutuações em parâmetros dos sistemas
(volume injetado, velocidade de injeção, força iônica e inserção acidental de bolhas de
ar) e na presença de contaminação e/ou passivação gradual do eletrodo de trabalho.
Métodos para determinação de diclofenaco (DCF) usando FIA com detecção
amperométrica e simultânea de DCF e codeína (CO) por BIA com detecção
amperométrica também foram desenvolvidos.
O método do padrão interno foi implementado no sistema de análise por injeção
em fluxo com detecção por amperometria de múltiplos pulsos (FIA-MPA) mediante a
aplicação de uma sequência de pulsos de potenciais ao eletrodo de trabalho em função
do tempo. O analito (+0,80 V/300ms) e o padrão interno (-0,05 V/400ms) foram
detectados seletivamente, um em cada pulso de potencial. Melhoras significativas foram
obtidas na precisão do método quando os resultados obtidos antes e após a normalização
(usando o método do padrão interno) foram comparados. As seguintes variações foram
calculadas, respectivamente, antes e após a normalização dos resultados usando o
método do padrão interno. Variação na velocidade de vazão de 3,0 para 1,0 mL min-1
(-57% e < 1%); no volume de injeção de 300 para 100 μL (-63% e 3%); força iônica de
0,60 para 0,77 mol L-1 (-44 e 0,2%) e antes e após a inserção de bolhas de ar no sistema
(-9,6% e 1,7%). Uma melhora significativa também foi obtida no coeficiente de correlação da curva de calibração na presença de problemas de passivação ou
contaminação do eletrodo de trabalho. O coeficiente de correlação foi calculado,
respectivamente, em 0,975 e 0,998, antes e após a normalização dos resultados pelo
método do PI.
O método do padrão interno também foi aplicado para corrigir erros em sistemas
de análise por injeção em batelada (BIA) com detecção amperométrica provenientes do
procedimento de injeção (velocidade de injeção e volume injetado) quando seringas
descartáveis foram utilizadas. Os resultados obtidos antes e após a normalização dos
resultados pelo método do PI foram os seguintes, respectivamente: estudo de
repetibilidade (DPR=6,4 e 1,8%; n = 8), coeficientes de correlação (R=0,954 e 0,997) e
erros obtidos na análise de amostras sintéticas (9,4 ± 1,5% e 3,5 ± 0,7; n = 8).
A determinação de DCF por FIA-MPA foi implementada através da aplicação de
dois pulsos de potenciais ao eletrodo de BDD em meio de H2SO4 0,1 mol L-1 como
eletrólito suporte: (i) +1,2 V / 50 ms para oxidação e quantificação do DCF e, (ii) 0,0 V
/ 50 ms para constante limpeza eletroquímica do eletrodo de trabalho. O sistema
apresentou boa estabilidade (RSD = 1,0%; n=10) e elevada frequência analítica (135
injeções h-1). O método apresentou resposta linear entre 5 e 50 μmol L-1 e os limites de
detecção e quantificação foram calculados em 0,14 e 0,46 μmol L-1, respectivamente. O
método proposto foi aplicado na determinação de DCF em formulações farmacêuticas e
os resultados obtidos foram similares ao obtidos por HPLC a um nível de confiança de
95%.
A determinação simultânea de DCF e CO foi realizada usando os seguintes pulsos
de potenciais: (i) +1,1 V / 50 ms: oxidação e quantificação de DCF; (ii) +1,4 V / 50 ms:
para oxidação simultânea de DCF e CO; (iii) 0,0 V / 200 ms: para constante limpeza
eletroquímica do eletrodo de BDD. A corrente de oxidação da CO foi obtida pela subtração entre as correntes detectadas em 1,4 e 1,1 V mediante uso de um fator de
correção. O sistema apresentou boa estabilidade (RSD= 1,1 e 0,9% para DCF e CO,
respectivamente, n=10) e elevada frequência analítica (~300 injeções h-1). O método
apresentou resposta linear entre 10 e 50 μmol L-1 para o DCF e entre 7,1 e 35,7 μmol L-1
para CO. O LD e o LQ foram calculados, respectivamente, em 1,1 e 3,7 μmol L-1, para
DCF e 1,0 e 3,3 μmol L-1 para CO. O método proposto foi aplicado na determinação
simultânea de DCF e CO em formulações farmacêuticas e os resultados obtidos foram
similares ao obtidos por HPLC a um nível de confiança de 95%. / Doutor em Química
|
73 |
Eletroxidação de cloranfenicol e outros poluentes organicos utilizando reatores eletroquimicos, constituidos de anodos tipo DSA ou de diamante dopado com boro (DDB) / Electrooxidation of chloramphenicol and otherpollutants using electrochemical reactors composed with a DSA type anode or a boron-doped diamond anodeSpitzer, Marcos 30 September 2005 (has links)
Orientador: Rodnei Bertazzoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-05T06:46:31Z (GMT). No. of bitstreams: 1
Spitzer_Marcos_D.pdf: 1019872 bytes, checksum: 57974ac02038eb53169c99987a119811 (MD5)
Previous issue date: 2005 / Resumo: O método de oxidação eletroquímica foi aplicado a soluções aquosas contendo cloranfenicol (CAP) e outros compostos orgânicos. Para isso, utilizou-se um anodo de óxido condutor, comercial, tipo DSA®, de composição 70TiO2-30RuO2 e um anodo de diamante dopado com boro (DDB) tipo comercial. Cada anodo foi instalado em um reator tipo filtro-presa, em escala de bancada, para processamento de 2 a 3 L de solução em modo de batelo-reciclo. Inicialmente, nos reatores construídos foram realizados estudos voltamétricos, em modo hidrodinâmico. Sobre um catodo de aço inoxidável, antes da evolução de H2, observou-se a redução do grupo NO2 do CAP a HO-NH- a pH=5, e em potenciais anódicos, sobre o DSA®, observou-se o início reação de evolução de O2 a partir de 1 V vs. ECS e que a presença de CAP reduz as correntes de evolução de O2. Sobre o DDB, o CAP é oxidado a partir de 0,6 V resultado na passivação do anodo. A partir de 2,2 V observa-se o início da evolução de O2 sobre o DDB, resultando na eliminação do filme passivador. Em seguida, eletrólises exaustivas foram realizadas, em modo galvanostático, com ambos os anodos, dentro da região de evolução de O2. Cinéticas de pseudo-primeira ordem foram observadas dos decaimentos ds CAP sobre o DSA®, na faixa de 50 a 180 mA cm-2, e sobre o DDB, na faixa de 10 a 30 mA cm-2. Os decaimentos da demanda química de O2 (DQO) e do carbono orgânico total (COT) também apresentaram essa cinética quando as reações de oxidação sobre o DDB tornavam-se controladas pelos processos de transporte de massa. A partir de eletrólises de soluções de K2SO4 com o DDB observou-se a geração de H2O2. Os números adimensionais Sherwood (Se), Reynolds (Re) e Schmidt (Sc) foram determinados a partir de dados de transporte de massa obtidos a partir de cinéticas da degradação do CAP em função da vazão. No reator composto de DSA® observou-se um regime de fluxo laminar a baixo de Re = 2000 e um regime de fluxo turbulento acima desse valor, como esperado para um reator de placas paralelas. No reator de DDB, devido o aumento da área da secção transversal do compartimento entre eletrodos, há uma elevação de turbulência da face do anodo, impedindo a formação de um regime de fluxo laminar bem definido. Utilizando um efluente real contendo fenóis e derivados, foram aplicadas valores apropriados de densidade de corrente (Jap) para aumento dos valores de eficiência de corrente e diminuição dos índices de consumo energético. Aplicando-se um perfil exponencial de Jap (t) obteve-se um rendimento de corrente médio de 95 % e um consumo de 23,5 kWh por kg de O2. Com isso foi possível propor um método de operação de reatores de DDB para elevação dos índices de eficiência. De modo geral, os anodos de Ti/70TiO2-30RuO2 e de DDB ótimos desempenhos para a eletroxidação de cloranfenicol (CAP) e outros compostos orgânicos e para redução da DQO e do COT / Abstract: Electrochemical oxidation was used as a method for organic pollutant degradation in aqueous media. In the technique was used in solutions containing chloramphenicol (CAP) and phenolic compounds. A commercial DSA® type anode, of composition 70TiO2-30RuO2, and a boron-doped diamond anode (BDD) were used. Each anode was mounted in a filter-press type reactor connected to a recirculating flow system with 3 L of capacity. Initially, voltammetric studies were carried out with electrochemical reactors operating in hydrodynamic mode. On the DSA® type anode O2 evolution reaction was observed after 1 V vs. SCE and the current densities for O2 evolution decreased when chloramphenicol was present in solution. On stainless steel cathode, before H2 evolution, reduction of NO2 group to HO-NH- group was observed for CAP molecule, at pH = 5. On DDB, the anode was passived with an organic film at potentials from 0.6 V. Current responses on DDB anode were restored after anodic treatments within O2 evolution range of potentials. On BDD, O2 evolution took place after 2.2 V vs SCE. Galvanostatic experiments were carried out within the range of potentials for O2 evolution. Pseudo-first order kinetics were observed for CAP concentration decay on the DSA® anode, when current densities (Jap) were ranged from 50 to 180 mA cm-2, and from 10 to 30 mA cm-2 on DDB anode. Chemical oxygen demand (COD) and total organic carbon (TOC) showed linear concentration decays when the oxidation reactions were controlled by charge transfer process and it showed exponential decays when these reactions were controlled by mass transfer process. H2O2 production on DDB anode was investigated as function of Jap. Dimensionless numbers and their mass transfer figures of merit were studied from mass transport data of CAP decays as function of several flow rates. In the reactor composed by DSA® anode, a laminar flow was observed below Reynolds (Re) equal 2000 and a turbulent flow was observed above this value. In the BDD reactor, the transition between laminar and turbulent flow was not observed. Using a real effluent composed by phenols and derivates, appropriate values of Jap was applied on DDB reactor to increase the anodic efficiency and to reduce the energy consumption per kg of O2. Applying an exponential profile of Jap in galvanostatic experiments, an anodic efficiency of 95% was reached, corresponding to an energy consumption of 23,5 kWh per kg of O2. From these results an operation method of BDD reactors arose in order to increase the performance of this electrochemical device. Good performances were observed when DSA® and BDD anodes were used in electrochemical oxidation of chloramphenicol and other organic pollutants, especially in BDD case / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
|
74 |
Desenvolvimento de um método por ponto nuvem dos hormônios naturais E1 e E2 em amostras de urina e determinação por CLAE/EC utilizando eletrodo de diamante dopado com boro / Development of a cloud point method of E1 and E2 natural hormones from urine samples and determination by HPLC/EC using boron doped diamondAmorim, Kamila Pereira de 06 August 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T08:39:40Z
No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T08:41:11Z (GMT) No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-08T08:41:11Z (GMT). No. of bitstreams: 2
Dissertação - kamila Pereira de Amorim - 2015.pdf: 1653482 bytes, checksum: 57f33de27efd496be7b4807548727455 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-08-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Cloud point extraction method (CPE) was used for the determination of estrone (E1) and 17β-estradiol (E2) hormones in human urine. The combination of the electrochemical detection techniques with high-performance liquid chromatography (HPLC-EC) was used for the detection and quantification of these hormones. A boron doped diamond electrode (BDD) pretreated cathodically was used as electrode material for all electrochemical measurements. The optimized chromatographic parameters resulted in a mobile phase composition of KH2PO4 (0.01 mol L-1; pH 5.0) / ACN (72:28 V/V), flow 1.2 ml min-1. An applied potential for electrochemical detection of 1.0 V x Ag/AgCl (3.0 mol L-1) was selected from hydrodynamic voltammograms constructed for each hormone changing the potential between 0.3 V and 1.2 V x Ag/AgCl (3.0 mol L-1). Limits of detection (S/N = 3) of 500 ng mL-1 and limits of quantification of 800 ng mL-1 were obtained for both E1 and E2 hormones without any extraction process. Urine samples at pH 5.0 and 7.0 were investigated aiming the influence of pH on the efficiency of the CPE process, and the optimum results for the most current signal of the hormones was obtained at pH 7.0. Extractor solvent volumes were changed in the 0.5-2.5 mL range, and the optimum results were obtained when using 1.0 mL of Tergitol TMN-6 surfactant (10% aqueous solution). From the equation of the calibration curves obtained with and without the CPE procedure it was possible to determine the pre-concentration factor (FC) and all the other parameters involving the efficiency of CPE method. A comparison of the efficiency of CPE method with direct liquid-liquid extraction with the organic solvent CCl4 was carried out and the results showed that the CPE method was quite superior to liquid-liquid extraction. The validation of the method was carried out from intra-day recovery experiments and inter-day and evaluated the accuracy, precision and repeatability. The proposed method was applied to individual samples of urine of 1 man, 1 pregnant woman, 1 woman in fertile age, and 1woman in lactating stage. The values of the variation coefficients of the recovery percentages were lower than 15%. / Método de extração por ponto nuvem (EPN) foi usado para a determinação dos hormônios estrona (E1) e 17β-estradiol (E2) em urina humana. A combinação entre as técnicas de detecção eletroquímica e cromatografia líquida de alta eficiência (CLAE-EC) foi usada para a detecção e quantificação desses hormônios. Um eletrodo de diamante dopado com boro (DDB) pré-tratado catodicamente foi usado como material de eletrodo para todas as determinações eletroquímicas. Os parâmetros cromatográficos otimizados resultaram em uma composição de fase móvel de KH2PO4 (0,01 mol L-1; pH 5,0) / ACN (72:28 V/V) vazão de 1,2 mL min-1. Um potencial aplicado para a detecção eletroquímica de 1,0 V x Ag/AgCl (3 mol L-1) foi selecionado a partir de voltamogramas hidrodinâmicos construídos para cada hormônio variando-se o potencial entre 0,3 V e 1,2 V x Ag/AgCl (3,0 mol L-1). Limites de detecção (S/R = 3) de 500 ng mL-1 e limites de quantificação de 800 ng mL-1 foram obtidos para ambos os padrões dos hormônios E2 e E1 sem qualquer processo de extração. Amostras de urina em pH 5,0 e 7,0 foram investigadas quanto a influência do pH na eficiência do processo de extração, e o melhor resultado referente ao maior sinal de corrente dos hormônios foi obtido em pH 7,0. Os volumes de solvente extrator foram variados na faixa de 0,5-2,5 mL e o melhor resultado referente ao sinal de corrente dos hormônios foi obtido pelo uso de 1,0 mL de solução aquosa 10% do surfactante Tergitol TMN-6. A partir da equação da reta obtida das curvas analíticas, com e sem o procedimento de EPN, foi possível determinar o fator de pré-concentração (FC) e todos os demais parâmetros envolvendo a eficiência do método de EPN. Uma comparação sobre a eficiência dos métodos de EPN com extração direta líquido-líquido com o solvente orgânico CCl4 foi realizada e os resultados mostraram que método de EPN mostrou-se bastante superior a extração líquido-líquido. A validação do método foi feita a partir de ensaios de recuperação intra-dia e inter-dia, sendo avaliadas a exatidão, precisão e repetitividade. O método proposto foi aplicado em amostras individuais de urina de 1 homem, 1 mulher gestante, 1 mulher em idade fértil e 1 mulher lactante. Os valores dos coeficientes de variação das porcentagens de recuperação foram menores que 15%.
|
75 |
Comportamento eletroquímico de nitrofuranos em eletrodos de diamante dopado com boro-modelo para o mecanismo de ação de nitrocompostos com atividades antichagásica / Electrochemical behaviour of nitrofurans on highly boron doped diamond Electrodes-model for the action mechanism of the nitrocompounds with antichagasic activityMurilo Sérgio da Silva Julião 09 March 2007 (has links)
O comportamento eletroquímico do Nitrofural (NFZ) foi estudado em eletrodos de pasta de carbono, carbono vítreo e diamante altamente dopado com boro (EDADB) em tampão Britton-Robinson (BR) usando a voltametria cíclica. Os melhores resultados foram obtidos em EDADB, no qual foi possível estabilizar o radical aniônico (R-NO2•‾) em meio predominantemente aquoso, como também estudar a interação entre o R-NO2•‾ a glutationa (GSH), a L-cisteína (Cis) e o O2. Somente na superfície do EDADB, o NFZ foi diretamente reduzido à amina derivada (R-NH2) no intervalo de 2,02 ≤ pH ≤ 4,03 num processo envolvendo seis (6,0 ± 0,4) elétrons e seis prótons. Na faixa de 7,04 ≤ pH ≤ 12 e meio predominantemente aquoso, a etapa de redução desmembrou-se em seus dois componentes: a redução do NFZ ao nitro radical aniônico (R-NO2•‾) e posterior redução deste ao derivado hidroxilamínico (R-NHOH) em processos envolvendo um e três (3,1 ± 0,1) elétrons respectivamente. No sentido anódico da varredura dos voltamogramas cíclicos registrados em pH 8,06, observou-se a oxidação da hidroxilamina ao derivado nitroso (R-NO), num processo envolvendo 2 (1,7 ± 0,2) elétrons e 2 prótons. Além disto, um novo pico de oxidação não relatado na literatura em qualquer material de eletrodo foi detectado em pH ≤ 8,06, que foi observado não importando se o NFZ havia sido previamente reduzido ou não. O cálculo do número de elétrons, n, envolvido em cada etapa eletroquímica foi satisfatoriamente estimado usando-se a equação de Randles-Sevcik. Na presença de [Tiol] ≤ 3,7 x 10-2 mol L-1, o NFZ é reduzido ao aduto R-NO-Tiol em um processo eletroquímico envolvendo dois elétrons e dois prótons. Por outro lado, o O2 atua como um aceptor de R-NO2•‾ e a constante de equilíbrio para a transferência monoeletrônica do R-NO2•‾ para o oxigênio, kO2, é 60. O processo é catalítico e pode ser utilizado para a determinação analítica de NFZ na faixa de 9,9 x 10-7 ≤ [NFZ] ≤ 1,1 x 10-5 mol L-1 em pH 8,06, com sensibilidade amperométrica de 2,2 x 104 µA L mol-1 cm-2 e limite de detecção de 3,4 x 10-7 mol L-1. Os parâmetros analíticos foram similares aqueles obtidos em pH 4,0 usando a redução direta do NFZ à respectiva amina derivada em um processo envolvendo seis elétrons e seis prótons. A caracterização do processo de redução total do NFZ em meio aquoso e velocidades de varredura relativamente baixas, 100 mV s-1, somente foi possível devido às características superficiais intrínsecas do EDADB, o qual estabiliza o radical livre, R-NO2•‾, permitindo trabalhar numa ampla janela de potencial, sem haver perda do sinal de oxidação do R-NO2•‾. / The electrochemical behaviour of nitrofural (NFZ) at carbon paste, glassy carbon and highly boron doped diamond (HBDD) electrodes was studied in Britton- Robinson (BR) buffer using cyclic voltammetry. The best results were obtained at HBDD electrodes, in which it was possible to stabilize the radical anion (R-NO2•‾) in predominantly aqueous medium as well as to study the interaction between the radical anion and glutathione (GSH), L-cysteine (Cys), and O2. Only at HBDD surface, NFZ was directly reduced to the amine derivative (R-NH2) in the pH range of 2.02 to 4.03 in a process involving six (6.0 ± 0.4) electrons and six protons. In the range of pH 7.04 to 12 and, predominantly aqueous medium, the reduction step split into its two components: the reduction of NFZ to the nitro radical anion (R-NO2•‾) and reduction of R-NO2•‾ to hydroxylamine derivative (R--NHOH) in processes involving one and three (3.1 ± 0.1) electrons respectively. On the anodic scan of the cyclic voltammograms and at pH 8.06, it was observed the oxidation of the hydroxylamine to the nitroso derivative (R-NO), in a process involving 2 (1.7 ± 0.2) electrons and 2 protons. In addition and unreported in the literature on any electrode material, was the detection of a new oxidation peak at pH > 8.06, which was observed regardless of whether NFZ had been previously reduced or not. The calculation of n, number of electrons, involved in each electrochemical step was satisfactorily accomplished using the Randles-Sevcik equation. In presence of [Thiol] ≤ 3.7 x 10-2 mol L-1 NFZ is directly reduced to R-NO---Thiol adducts in an electrochemical process involving two electrons and two protons. On the other side, O2 acts as a R-NO2•‾ scavenger and the equilibrium constant for the electron transfer from nitro radical to oxygen, kO2, is 60. The process is catalytic and can be used to the analytical determination of NFZ in the range of 9.9 x 10-7 ≤ [NFZ] ≤ 1.1 x 10-5 mol L-1 at pH 8.0, with amperometric sensitivity of 2.2 x 104 µA L mol-1 cm-2 and detection limit of 3.4 x 10-7 mol L-1. The analytical parameters were similar to those obtained at pH 4.03 using the direct reduction of NFZ to the respective amine derivative in a process involving six electrons and six protons. The characterization of NFZ global reduction process in aqueous medium and at relative low scan rate, 100 mVs-1, was only possible due the intrinsic superficial characteristics of the HBDD electrode, which stabilize the R-NO2•‾ free radical, allowing to work in a large potential window, without losing the R-NO2•‾ oxidation signal.
|
76 |
[pt] DESENVOLVIMENTO DE MÉTODOS ELETROANALÍTICOS PARA A DETERMINAÇÃO DE FUNGICIDAS DA CLASSE DAS ESTROBILURINAS UTILIZANDO ELETRODOS DE FILME DE BISMUTO E DE DIAMANTE DOPADO COM BORO / [en] ELECTROANALYTICAL METHODS FOR THE DETERMINATION OF FUNGICIDES OF THE STROBILURIN CLASS USING THE BISMUTH FILM ELECTRODE AND THE BORON-DOPED DIAMOND29 November 2021 (has links)
[pt] O monitoramento de resíduos de pesticidas é extremamente importante e isso se dá pelo emprego de métodos analíticos adequados para avaliar a sua presença em compartimentos ambientais e a contaminação de alimentos com esses agentes. Os pesticidas da classe das estrobilurinas vêm se tornando os mais utilizados para o controle dos fungos e apesar da propagada baixa toxicidade e rápida degradação, estudos devem ser realizados para averiguar o nível de exposição dos humanos a tais substâncias. Estudos com as estrobilurinas (azoxistrobina, cresoxim-metílico, dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina e trifloxistrobina) utilizando o eletrodo de trabalho de diamante dopado com boro (DDB) foram realizados por voltametria cíclica e voltametria de onda quadrada (SWV) e indicaram dois picos de oxidação (varredura anódica) em potenciais distintos. Dados experimentais e da literatura permitiram supor que para cresoxim-metílico e dimoxistrobina o primeiro pico de oxidação tem um mecanismo irreversível com 2 mols de elétrons por mol de analito e o segundo pico de oxidação com mecanismo quase-reversível. Para picoxistrobina, os dois picos de oxidação são irreversíveis com 2 mols de elétrons por mol de analito. Para piraclostrobina os dois picos de oxidação são quase-reversíveis. Métodos por SWV foram desenvolvidos utilizando DDB para determinação de cresoxim-metílico, picoxistrobina e piraclostrobina. As varreduras anódicas foram feitas entre: +1000 a +1750 mV (medição do sinal em +1420 mV) para cresoxim-metílico; +1100 a +1800 mV (medição do sinal em +1450 mV) para picoxistrobina e +1050 a +2100 mV (medição do sinal em +1280 mV) para piraclostrobina. O eletrólito suporte foi tampão acetato (0,05 mol L-1; pH 4,0) para a determinação de cresoxim-metílico e piraclostrobina e tampão Britton-Robinson (0,04 mol L-1; pH 2,0) para a picoxistrobina. Resposta analítica linear para cresoxim-metílico foi do limite de quantificação, LOQ, (0,9 umol L-1 ou 0,27 mg L-1) até 34,0 μmol L-1 com R2> 0,999. Para picoxistrobina a faixa linear foi do LOQ (0,7 mol L-1 ou 0,25 mg L-1) a 20,0 μmol L-1 (R2> 0,994). Já para piraclostrobina a faixa linear foi do LOQ (0,8 μmol L-1 ou 0,32 mg L-1) a 20,0 μmol L-1 (R2> 0,991). Os métodos foram aplicados na análise de amostras de suco de uva (cresoxim-metílico e piraclostrobina) e águas naturais (picoxistrobina e piraclostrobina). As recuperações variaram de 91,6 a 105,3 porcento dependendo da estrobilurina. Os métodos propostos foram comparados com cromatografia líquida de alta eficiência (HPLC) e os resultados não indicaram diferença significativa entre eles. Amostras de suco de uva comercial foram fortificadas na concentração do limite máximo permitido pela legislação, sendo o analito pré-concentrado dez vezes por extração em fase sólida (SPE), com cartucho C18, obtendo-se recuperações entre 95,4 a 99,5 porcento dependendo da estrobilurina. Dados experimentais indicaram que não houve degradação térmica significativa para as estrobilurinas em soluções aquecidas a 60 °C durante 2 h. Não foi possível propor um perfil simples de cinética para degradação por exposição ao UV para o cresoxim-metílico. Para picoxistrobina e piraclostrobina, um modelo de cinética de segunda ordem pode ser atribuído para a degradação por exposição ao UV. Métodos com a abordagem de análise por injeção em batelada (BIA) com detecção amperométrica no eletrodo de DDB foram desenvolvidos para a determinação de dimoxistrobina e picoxistrobina em águas naturais. Os métodos apresentaram uma frequência de análise de 180 injeções h-1 (dimoxistrobina) e 108 injeções h-1 (picoxistrobina), e precisão satisfatória (abaixo de 5 porcento). Resposta analítica linear para dimoxistrobina foi de 1,3 μmol L-1 (0,41 mg L-1) a 60,0 μmol L-1 com R2> 0,999 e para picoxistrobina foi de 5,3 μmol L-1 (1,95 mg L-1) e 100,0 μmol L-1 (R2> 0,999). Valores de recuperação obtidos nas amostras de águas naturais fortificadas com os analitos foram entre 80,2 e 105,6 porcento dependendo do analito. Além disso, uma estratégia simples para detectar a presença de moléculas interferentes em amostras de água com base na amperometria de múltiplos pulsos foi apresentada com sucesso. Um método voltamétrico de redissolução anódica por pulso diferencial usando o eletrodo de filme de bismuto foi desenvolvido para a determinação de picoxistrobina em amostras de urina e águas naturais. O ciclo de medição começou com a aplicação de um potencial de deposição de -700 mV durante 60 s para a formação in situ do filme Bi e a acumulação do analito. A varredura de potencial foi no sentido anódico entre +790 e +1050 mV. Provou-se que, nas condições empregadas, uma quantidade significativa de filme de Bi ainda está presente na superfície do eletrodo de carbono vítreo após a varredura anódica, com uma velocidade de 40 mV s-1. A presença de Bi é fundamental para a acumulação e oxidação de picoxistrobina (pico máximo em +954 mV) durante redissolução. O eletrólito suporte foi HCl 1,0 mol L-1. Um procedimento de limpeza foi desenvolvido a fim de minimizar o efeito de memória. Resposta analítica linear para picoxistrobina foi observada de 2,8 μmol L-1 (1,0 mg L-1) até 19,0 μmol L-1 (R2> 0,994). SPE permitiu a pré-concentração do analito e eliminou as interferências nas amostras de urina. Recuperações de 89,3 a 104,8 porcento foram encontradas e a interferência das outras estrobilurinas ao método foram avaliadas. O método proposto foi comparado com HPLC e os resultados indicam que não houve diferença significativa entre eles. / [en] The monitoring of pesticide residues is extremely important and this is accomplished by the use of methods to assess their presence in environmental compartments and in food stuff contaminated with these agents. The pesticides of the strobilurin class have become the most widely used for fungi control and despite the low toxicity and rapid degradation, studies should be conducted to ascertain the level of human exposure to such substances. Studies with the strobilurin pesticides (azoxystrobin, kresoxim-methyl, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin and trifloxystrobin) were performed by cyclic voltammetry and square wave voltammetry (SWV) using the boron-doped diamond (BDD). Results indicated two oxidation peaks (anodic scan) at different potentials. Based on experimental data and literature it is assumed that for kresoxim-methyl and dimoxystrobin the first oxidation peak comes from an irreversible mechanism involvieng 2 moles of electrons per mole of analyte while the second oxidation peak is from a quasi-reversible mechanism. For picoxystrobin, the two oxidation peaks are from irreversible processes involving 2 moles of electrons per mole of analyte. For pyraclostrobin, the two oxidation peaks are from quasi-reversible processes. SWV methods were developed for determination of kresoxim-methyl, pyraclostrobin and picoxystrobin using the BDD. The anodic scans were made between: +1000 to +1750 mV (measured signal at +1420 mV) for kresoxim-methyl; +1100 to +1800 mV (measured signal at +1450 mV) for picoxystrobin and +1050 to +2100 mV (measured signal at +1280 mV) for pyraclostrobin. The supporting electrolyte was acetate buffer (0.05 mol L-1, pH 4.0) for the determination of kresoxim-methyl and pyraclostrobin and Britton-Robinson buffer (0.04 mol L-1, pH 2.0) to picoxystrobin. Linear analytical response to kresoxim-methyl was the limit of quantification, LOQ (0.9 μmol L-1 or 0.27 mg L-1) to 34.0 μmol L-1 with R2> 0.999. For picoxystrobin the linear range was from LOQ (0.7 μmol L-1 or 0.25 mg L-1) to 20.0 μmol L-1 (R2> 0.994). Pyraclostrobin presented linear range from LOQ (0.8 μmol L-1 and 0.32 mg L-1) to 20.0 μmol L-1 (R2> 0.991). The methods were applied in the analysis of grape juice samples (kresoxim-methyl and pyraclostrobin) and in natural waters (picoxystrobin and pyraclostrobin). The recoveries ranged from 91.6 to 105.3 percent depending on the strobilurin. The results obtained with the proposed methods were compared with the ones achieved by high performance liquid chromatography (HPLC) indicating no significant difference between them. Commercial grape juice samples were fortified at the maximum concentration allowed legislation and the analytes were pre-concentrated (tenfold) by solid phase extraction (SPE) in a C18 cartridge analyte Recoveries were between 95.4 to 99.5 percent depending on the strobilurin. Experimental data indicate that no significant thermal degradation occurred for strobilurins in solutions heated at 60 °C for 2 h. It was not possible to propose a simple kinetic profile for the UV degradation of kresoxim-methyl. However, for picoxystrobin and pyraclostrobin, a second-order kinetic model explains their degradation profile. Methods using batch injection analysis (BIA) with amperometric detection on a BDD electrode have also been developed for the determination of picoxystrobin and dimoxystrobin in natural waters. The methods showed an analytical frequency of 180 injections h-1 (dimoxystrobin) and 108 injections h-1 (picoxystrobin) and satisfactory precision (less than 5 percent). Linear analytical response for dimoxystrobin was from 1.3 μmol L-1 (0.41 mg L-1) to 60.0 μmol L-1 with R2> 0.999 while for picoxystrobin, the range was from 5.3 μmol L-1 (1.95 mg L-1) to 100.0 μmol L-1 (R2> 0.999). Recoveries achieved for analyte fortified water samples were between 80.2 and 105.6 percent depending on the analyte. In addition, a simple strategy to detect the presence of interfering molecules in water samples, based on multiple pulse amperometry, was successfully introduced. A stripping anodic differential pulse voltammetric method using the bismuth film electrode was developed for the determination picoxystrobin in urine samples and in natural waters. The measurement cycle started with the application of a deposition potential of -700 mV for 60 s for the in situ formation of the Bi film and for the accumulation of analyte. The potential was scanned in the anodic direction between +790 and +1050 mV. It has been proven that, under the conditions employed, a significant amount of Bi film is still present on the surface of the glassy carbon electrode after anodic sweep, with a speed of 40 mV s-1. The presence of Bi is essential for the accumulation and oxidation of picoxystrobin (maximum peak at +954 mV) during stripping. The supporting electrolyte was HCl 1.0 mol L-1. A cleaning procedure was developed to minimize the memory effect. Analytical linear response was observed for picoxystrobin from 2.8 μmol L-1 (1.0 mg L-1) to 19.0 μmol L-1 (R2> 0.994). SPE allowed the pre-concentration of the analyte and elimination of interferences from urine samples. Recoveries from 89.3 to 104.8 percent were found. Interference of other strobilurin the method were evaluated. The proposed method was compared with HPLC and the results indicate no significant difference between them.
|
77 |
Porézní borem dopované diamantové elektrody: Charakterizace a využití v elektroanalýze / Porous Boron-Doped Diamond Electrodes: Characterisation and Application for ElectroanalysisBaluchová, Simona January 2021 (has links)
This dissertation thesis presents newly developed electrode materials based on porous boron- doped diamond (BDDporous) and their potential applications in electroanalysis. Particularly, these novel BDDporous electrodes (twelve in total) were thoroughly electrochemically characterised and compared, and the ones with the most promising properties were selected to develop reliable voltammetric methods for detecting the neurotransmitter dopamine. Initially, the impact of selected fabrication parameters on the final properties and electrochemical behaviour of novel BDDporous electrodes was clarified; the following factors were specifically studied: (1) deposition template used, (2) boron-doping level, (3) growth time of the individual layers (i.e., porosity), (4) number of deposited layers (i.e., thickness), and (5) content of non-diamond (sp2 ) carbon impurities. Alterations in deposition conditions naturally resulted in BDDporous electrodes with diverse (i) structural and morphological features, which were investigated by scanning electron microscopy and Raman spectroscopy, and (ii) physical and electrochemical characteristics, examined by cyclic voltammetry. Besides, to assess the suitability of selected BDDporous electrodes for dopamine detection, other parameters, such as susceptibility to...
|
78 |
Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado / Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrodeVasconcelos, Vanessa Moura 11 September 2015 (has links)
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator), dopagem do eletrodo de DDB/Ti (5.000 e 15.000 ppm B/C), concentração inicial dos íons Fe2+ (0-0,10 mmol L-1) e dos corantes (10-250 mg L-1). As degradações dos corantes apresentaram uma cinética de pseudo ordem zero; exceto quando o corante RP-5 foi degradado pelo processo EF, sendo o melhor ajuste ao modelo de pseudo primeira ordem. Além disso, em iguais condições eletroquímicas o corante RP-5 foi degradado em menor tempo em relação ao RA-19; sendo que em todos os processos estudados os corantes foram totalmente removidos. Considerando a OA em célula com os eletrodos de DDB/Ti, a degradação foi positivamente influenciada pelo aumento da densidade de corrente e dopagem do eletrodo, especialmente em relação a cinética. Além disso, os corantes RA-19 e RP-5 foram completamente removidos em 35 e 50 min de eletrólise quando 100 mA cm-2 foi aplicada ao eletrodo de DDB/Ti dopado com 15.000 ppm relação B/C. Em 2 h, 37% em mineralização foi observado para ambos os corantes e a toxicidade do RA-19 diminuiu contra as bactérias Vibrio fischeri. Ainda nessa condição total mineralização foi alcançada após 8 h de degradação. A remoção de COT foi favorecida utilizando o reator contendo os eletrodos de DDB/Nb e CVR ao invés da célula eletroquímica, chegando a percentuais de 84 e 82% em 30 e 90 min para os corantes RA-19 e RP-5 que foram removidos em 7,5 e 5 min, respectivamente, quando a densidade de 41 mA cm-2 foi aplicada ao DDB/Nb durante a degradação via exclusivamente OA. Entre os processos realizados no reator, o EF foi o energeticamente mais favorável, promovendo remoção em COT de 60 e 74% para os corantes RA-19 e RP-5 com consumo energético de 204 e 208 kWh kg-1, além disso, a completa remoção dos corantes ocorreu em 15 e 7,5 min, respectivamente, quando o eletrólito continha íons Fe2+ na concentração de 0,10 mmol L-1 e aplicando-se -0,4 V vs Ag/AgCl ao eletrodo de CVR. Na degradação os corantes via CP o RA-19 e RP-5 foram completamente removidos em 30 e 15 min com mineralização de 72 e 82% em 90 min associada a consumos energéticos de 562 e 745 kWh kg-1, respectivamente, quando 41 mA cm-2 foi aplicada ao DDB/Nb. Por fim, concluiu-se que os resultados das degradações dos corantes foram promissores, já que rápida remoção dos corantes foi observada, além da parcial mineralização. Logo os processos propostos podem ser aplicados na remoção dos corantes em água; sendo necessários realizar mais estudos, principalmente em relação ao material eletródico e configuração do sistema eletroquímico visando a aplicação industrial. / The main problem involving the textile wastewater is theirs high coloration since they present dyes, which are chemically stable and can be toxic and/or carcinogenic. Therefore, when the textile wastewater are discarded in nature in the environment, even in low concentrations, they may cause not only aesthetic and environmental problems, but also can be harmful to human and animal health. In this context, the aim of the study was to evaluate the electrochemical degradation of two textile dyes, Reactive Blue 19 (RB-19) and Black 5 (RB-5) via Anodic Oxidation (AO) using as anodes Boron Doped Diamond electrodes (BDD) supported on titanium or niobium, via Electro-Fenton (EF) process and by combination of processes with electrogenerated H2O2 and AO (CP) using a Reticulated Vitreous Carbon electrode (RVC) as cathode. The degradations assays were carried out in an electrochemical cell with one compartment and in a filter-press flow reactor with two compartments. The efficiency of degradation was monitored by UV-VIS spectrophotometry, High Performance Liquid Chromatography (HPLC) and analysis of Total Organic Carbon (TOC). The variables studied were current density (10-100 mA cm-2 for cell and 4-41 mA cm-2 for reactor), doping of the BDD/Ti electrodes (5,000 e 15,000 ppm B/C), initial concentration of the Fe2+ ions (0-0,10 mmol L-1) and dyes (10-250 mg L-1). The kinetic results showed that the removal of dyes followed the model of pseudo zero order; except when the RB-5 dye was degraded by EF process, which the best fitted was to pseudo first order model. Furthermore, for equal conditions the RB-5 was degraded in less time in comparison to the RB-19. In addition, the dyes were fully removed in all the processes studied. Regarding the AO in cell with BDD/Ti, the degradation was positively influenced by the increasing in current density and doping of the electrode, primarily the kinetics parameters. In addition, total removal of RB-19 and RB-5 was achieved in 35 and 50 min of electrolysis when 100 mA cm-2 was applied to the electrode doped with 15,000 ppm ratio B/C. In 2 h, 37% in mineralization was attained for both dyes and the toxicity effect of the RB-19 decreased against the bacteria Vibrio fischeri. In this condition, total TOC removed was also reached after 8 h. The TOC removal was enhanced using the reactor fitted with BDD/Nb and RVC instead of the electrochemical cell, achieving TOC removal of 84 and 82% in 30 and 90 min for RB-19 and RB-5 which were removed in 7.5 and 5 min, respectively, when 41 mA cm-2 was applied to the BDD/Nb in the degradation exclusively via AO. Among the processes carried out in the reactor, the EF was the energetically most favourable since TOC removal of 60 and 74% for RB-19 and RB-5 with energy consumption of 204 and 208 kWh kg-1 were noted. In addition, the RB-19 and RB-5 were completely removed in 15 and 7.5 min, respectively, when the electrolyte containing 0.10 mmol L-1 of Fe2+ ions and -0.4 V vs Ag/AgCl was applied to CVR electrode. The combination of processes with electrogenerated H2O2 and AO for degradation of the dyes removed the RB-19 and RB-5 in 30 and 15 min with mineralization of 71.6 and 81.8% in 90 min associated to energy consumptions of 562 and 745 kWh kg-1 respectively, when 41 mA cm-2 was applied to BDD/Nb. Therefore, the degradation results of the dyes were promised since quickly removal of the dyes and partial mineralization were observed hence the proposed processes could be used to remove the dyes from water. However, more studies are needed to enable an industrial application, especially regarding the electrode material and configuration of the electrochemical system.
|
79 |
Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado / Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrodeVanessa Moura Vasconcelos 11 September 2015 (has links)
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator), dopagem do eletrodo de DDB/Ti (5.000 e 15.000 ppm B/C), concentração inicial dos íons Fe2+ (0-0,10 mmol L-1) e dos corantes (10-250 mg L-1). As degradações dos corantes apresentaram uma cinética de pseudo ordem zero; exceto quando o corante RP-5 foi degradado pelo processo EF, sendo o melhor ajuste ao modelo de pseudo primeira ordem. Além disso, em iguais condições eletroquímicas o corante RP-5 foi degradado em menor tempo em relação ao RA-19; sendo que em todos os processos estudados os corantes foram totalmente removidos. Considerando a OA em célula com os eletrodos de DDB/Ti, a degradação foi positivamente influenciada pelo aumento da densidade de corrente e dopagem do eletrodo, especialmente em relação a cinética. Além disso, os corantes RA-19 e RP-5 foram completamente removidos em 35 e 50 min de eletrólise quando 100 mA cm-2 foi aplicada ao eletrodo de DDB/Ti dopado com 15.000 ppm relação B/C. Em 2 h, 37% em mineralização foi observado para ambos os corantes e a toxicidade do RA-19 diminuiu contra as bactérias Vibrio fischeri. Ainda nessa condição total mineralização foi alcançada após 8 h de degradação. A remoção de COT foi favorecida utilizando o reator contendo os eletrodos de DDB/Nb e CVR ao invés da célula eletroquímica, chegando a percentuais de 84 e 82% em 30 e 90 min para os corantes RA-19 e RP-5 que foram removidos em 7,5 e 5 min, respectivamente, quando a densidade de 41 mA cm-2 foi aplicada ao DDB/Nb durante a degradação via exclusivamente OA. Entre os processos realizados no reator, o EF foi o energeticamente mais favorável, promovendo remoção em COT de 60 e 74% para os corantes RA-19 e RP-5 com consumo energético de 204 e 208 kWh kg-1, além disso, a completa remoção dos corantes ocorreu em 15 e 7,5 min, respectivamente, quando o eletrólito continha íons Fe2+ na concentração de 0,10 mmol L-1 e aplicando-se -0,4 V vs Ag/AgCl ao eletrodo de CVR. Na degradação os corantes via CP o RA-19 e RP-5 foram completamente removidos em 30 e 15 min com mineralização de 72 e 82% em 90 min associada a consumos energéticos de 562 e 745 kWh kg-1, respectivamente, quando 41 mA cm-2 foi aplicada ao DDB/Nb. Por fim, concluiu-se que os resultados das degradações dos corantes foram promissores, já que rápida remoção dos corantes foi observada, além da parcial mineralização. Logo os processos propostos podem ser aplicados na remoção dos corantes em água; sendo necessários realizar mais estudos, principalmente em relação ao material eletródico e configuração do sistema eletroquímico visando a aplicação industrial. / The main problem involving the textile wastewater is theirs high coloration since they present dyes, which are chemically stable and can be toxic and/or carcinogenic. Therefore, when the textile wastewater are discarded in nature in the environment, even in low concentrations, they may cause not only aesthetic and environmental problems, but also can be harmful to human and animal health. In this context, the aim of the study was to evaluate the electrochemical degradation of two textile dyes, Reactive Blue 19 (RB-19) and Black 5 (RB-5) via Anodic Oxidation (AO) using as anodes Boron Doped Diamond electrodes (BDD) supported on titanium or niobium, via Electro-Fenton (EF) process and by combination of processes with electrogenerated H2O2 and AO (CP) using a Reticulated Vitreous Carbon electrode (RVC) as cathode. The degradations assays were carried out in an electrochemical cell with one compartment and in a filter-press flow reactor with two compartments. The efficiency of degradation was monitored by UV-VIS spectrophotometry, High Performance Liquid Chromatography (HPLC) and analysis of Total Organic Carbon (TOC). The variables studied were current density (10-100 mA cm-2 for cell and 4-41 mA cm-2 for reactor), doping of the BDD/Ti electrodes (5,000 e 15,000 ppm B/C), initial concentration of the Fe2+ ions (0-0,10 mmol L-1) and dyes (10-250 mg L-1). The kinetic results showed that the removal of dyes followed the model of pseudo zero order; except when the RB-5 dye was degraded by EF process, which the best fitted was to pseudo first order model. Furthermore, for equal conditions the RB-5 was degraded in less time in comparison to the RB-19. In addition, the dyes were fully removed in all the processes studied. Regarding the AO in cell with BDD/Ti, the degradation was positively influenced by the increasing in current density and doping of the electrode, primarily the kinetics parameters. In addition, total removal of RB-19 and RB-5 was achieved in 35 and 50 min of electrolysis when 100 mA cm-2 was applied to the electrode doped with 15,000 ppm ratio B/C. In 2 h, 37% in mineralization was attained for both dyes and the toxicity effect of the RB-19 decreased against the bacteria Vibrio fischeri. In this condition, total TOC removed was also reached after 8 h. The TOC removal was enhanced using the reactor fitted with BDD/Nb and RVC instead of the electrochemical cell, achieving TOC removal of 84 and 82% in 30 and 90 min for RB-19 and RB-5 which were removed in 7.5 and 5 min, respectively, when 41 mA cm-2 was applied to the BDD/Nb in the degradation exclusively via AO. Among the processes carried out in the reactor, the EF was the energetically most favourable since TOC removal of 60 and 74% for RB-19 and RB-5 with energy consumption of 204 and 208 kWh kg-1 were noted. In addition, the RB-19 and RB-5 were completely removed in 15 and 7.5 min, respectively, when the electrolyte containing 0.10 mmol L-1 of Fe2+ ions and -0.4 V vs Ag/AgCl was applied to CVR electrode. The combination of processes with electrogenerated H2O2 and AO for degradation of the dyes removed the RB-19 and RB-5 in 30 and 15 min with mineralization of 71.6 and 81.8% in 90 min associated to energy consumptions of 562 and 745 kWh kg-1 respectively, when 41 mA cm-2 was applied to BDD/Nb. Therefore, the degradation results of the dyes were promised since quickly removal of the dyes and partial mineralization were observed hence the proposed processes could be used to remove the dyes from water. However, more studies are needed to enable an industrial application, especially regarding the electrode material and configuration of the electrochemical system.
|
80 |
Cytochrome C biosensor for the determination of trace level arsenic and cyanide compoundsFuku, Xolile Godfrey January 2011 (has links)
In this work, an electrochemical method based on a cyt c biosensor has been developed, for the detection of selected arsenic and cyanide compounds. Boron Doped Diamond (BDD) electrode was used as a transducer, onto which cyt c was immobilised and used for direct determination of Prussian blue, potassium cyanide and arsenic trioxide by inhibition mechanism. The sensitivity as calculated from cyclic voltammetry (CV) and square wave voltammetry (SWV), for each analyte in phosphate buffer (pH= 7) was found to be (1.087- 4.488 Ã10-9 M) and the detection limits ranging from 0.0043- 9.1 μM. These values represent a big improvement over the current Environmental Protection Agency (EPA) and World Health Organisation (WHO) guidelines.
|
Page generated in 0.0495 seconds