• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 11
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Nutrição parenteral como fator de risco para infecção relacionada a cateter venoso central

Beghetto, Mariur Gomes January 2003 (has links)
O uso de cateteres venosos centrais (CVC) para fins diagnósticos e terapêuticos está incorporado à prática médica diária. Complicações sérias, com elevada morbidade e mortalidade, como a sepse, estão associadas a este procedimento. O diagnóstico das infecções relacionadas a cateter é fundamentado em sinais clínicos e laboratoriais. Os fatores de risco para infecção devem ser considerados por ocasião da utilização de CVC e estão relacionados ao paciente, ao cateter, ao tipo de solução administrada, ao profissional que manipula o cateter e ao agente etiológico. A identificação destes fatores permite a intervenção precoce sobre os mesmos e o manejo adequado do CVC e das complicações clínicas relacionadas. / The use of central venous catheters (CVC) for diagnosis and treatment is common in the medical practice. This procedure is associated with severe complications that present high morbidity and mortality rates, such as sepsis. The diagnosis of catheter-related infections is based on clinical signs and laboratorial confirmation through semi-quantitative or quantitative culture of the catheter tip. The risk factors for infection should be considered when using CVC. These factors may be related to the patient, to the catheter, to the type of solution administered, to the professional who handles the catheter and to the etiological agent. The identification of these factors will early intervention and ensure adequate management of CVC- related complications.
32

Nutrição parenteral como fator de risco para infecção relacionada a cateter venoso central

Beghetto, Mariur Gomes January 2003 (has links)
O uso de cateteres venosos centrais (CVC) para fins diagnósticos e terapêuticos está incorporado à prática médica diária. Complicações sérias, com elevada morbidade e mortalidade, como a sepse, estão associadas a este procedimento. O diagnóstico das infecções relacionadas a cateter é fundamentado em sinais clínicos e laboratoriais. Os fatores de risco para infecção devem ser considerados por ocasião da utilização de CVC e estão relacionados ao paciente, ao cateter, ao tipo de solução administrada, ao profissional que manipula o cateter e ao agente etiológico. A identificação destes fatores permite a intervenção precoce sobre os mesmos e o manejo adequado do CVC e das complicações clínicas relacionadas. / The use of central venous catheters (CVC) for diagnosis and treatment is common in the medical practice. This procedure is associated with severe complications that present high morbidity and mortality rates, such as sepsis. The diagnosis of catheter-related infections is based on clinical signs and laboratorial confirmation through semi-quantitative or quantitative culture of the catheter tip. The risk factors for infection should be considered when using CVC. These factors may be related to the patient, to the catheter, to the type of solution administered, to the professional who handles the catheter and to the etiological agent. The identification of these factors will early intervention and ensure adequate management of CVC- related complications.
33

Nutrição parenteral como fator de risco para infecção relacionada a cateter venoso central

Beghetto, Mariur Gomes January 2003 (has links)
O uso de cateteres venosos centrais (CVC) para fins diagnósticos e terapêuticos está incorporado à prática médica diária. Complicações sérias, com elevada morbidade e mortalidade, como a sepse, estão associadas a este procedimento. O diagnóstico das infecções relacionadas a cateter é fundamentado em sinais clínicos e laboratoriais. Os fatores de risco para infecção devem ser considerados por ocasião da utilização de CVC e estão relacionados ao paciente, ao cateter, ao tipo de solução administrada, ao profissional que manipula o cateter e ao agente etiológico. A identificação destes fatores permite a intervenção precoce sobre os mesmos e o manejo adequado do CVC e das complicações clínicas relacionadas. / The use of central venous catheters (CVC) for diagnosis and treatment is common in the medical practice. This procedure is associated with severe complications that present high morbidity and mortality rates, such as sepsis. The diagnosis of catheter-related infections is based on clinical signs and laboratorial confirmation through semi-quantitative or quantitative culture of the catheter tip. The risk factors for infection should be considered when using CVC. These factors may be related to the patient, to the catheter, to the type of solution administered, to the professional who handles the catheter and to the etiological agent. The identification of these factors will early intervention and ensure adequate management of CVC- related complications.
34

"Acesso venoso central para hemodiálise: avaliação prospectiva da ocorrência de complicações" / Central venous access for hemodialysis: prospective evaluation of complications.

Viviane Ferreira 08 July 2005 (has links)
As complicações de pacientes com insuficiência renal crônica submetidos ao tratamento hemodialítico representam desafios para os profissionais de saúde. A variabilidade de fatores de risco que predispõem a essas complicações têm sido, freqüentemente, investigada na literatura científica. Nesse sentido, objetivou-se descrever as complicações locais e sistêmicas dos pacientes com insuficiência renal crônica a partir da implantação do cateter temporário de duplo lúmen para hemodiálise até sua retirada definitiva. Trata-se de um estudo de segmento que avaliou prospectivamente os pacientes da implantação do cateter até sua retirada definitiva. Para o estabelecimento do grupo estudado foi considerado um período de seis meses consecutivos de julho a dezembro de 2003. Assim, após a aprovação do Comitê de Ética em pesquisa procedeu-se a coleta dos dados. Para análise dos resultados realizou-se a codificação das variáveis no banco de dados do programa Microsoft Excel mediante dupla digitação, e, utilizou-se o programa Software Statistical Package for Social Sciences, versão 10.0 na análise estatística. Dos 64 pacientes avaliados 38 (59,4%) eram do sexo masculino, 20 (31,2%) tinham como causa provável da insuficiência renal a nefroesclerose hipertensiva, e, 35 (54,7%) implantaram o cateter devido à necessidade do tratamento hemodialítico imediato. Totalizou-se no período 145 cateteres implantados, 29 (45,3%) dos pacientes tiveram implantes únicos, 98 (67,6%) dos acessos foram a veia jugular interna direita, 40 (27,6%) das trocas dos cateteres foram devido a febre. O tempo médio de permanência dos cateteres foi de 30 dias. A complicação local mais freqüente em 41 (64%) dos pacientes foi o funcionamento inadequado do cateter com 26 dias de média para a ocorrência, e, a complicação sistêmica mais freqüente em 24 (37,5%) foi a febre com 34 dias de média para sua ocorrência, 27 (42,2%) dos pacientes apresentaram infecção do sítio de inserção, e, 30 (47%) infecção da corrente sanguínea. O Staphylococcus aureus foi o microrganismo mais isolado em 10 (33,4%) das hemoculturas. Observou-se que 45 (70,4%) dos pacientes retiraram definitivamente o cateter devido à punção da fístula arteriovenosa. O estudo apontou aspectos preocupantes, dentre eles, o tempo de permanência do cateter, que expõe sobremaneira o paciente a diferentes complicações, em especial, a infecção. A confecção da fístula arteriovenosa representa uma importante alternativa que contrapõe o uso do cateter temporário. / Complications in chronic renal insufficiency patients under dialysis treatment represent important challenges to health professionals. The variety of risk factors predisposing towards these complications have frequently been discussed in scientific literature. Thus, this study aimed to describe the local and systemic complications of chronic renal insufficiency patients who were using a temporary double-lumen catheter for hemodialysis treatment, until its final withdrawal. A segment research prospectively studied patients from the moment the catheter was inserted until its final withdrawal. A period of six consecutive months, from July to December 2003, was considered to determine the group of patients ti be studied. Thus, after ethical approval, data were collected through interviews, clinical exams and patient record evaluation. For the result analysis, the variables were coded in a database through double data entry in Microsoft Excel and Software Statistical Package Social Sciences, version 10.0 was used for statistical analysis. 38 (59.4%) of the 64 patients were men, 20 (31.2%) showed hypertensive nephrosclerosis as the probable cause of insufficiency renal and 35 (54.7%) inserted the catheter due to the need for immediate hemodialysis treatment. 145 catheters were inserted during the period, 29 (45.3%) of which were single implants and the right internal jugular vein was the access in 98 cases (67.6%). Average catheter permanence time was 30 days. Catheters were substituted in 40 cases (27.6%) due to fever. The most frequent local complication was inadequate functioning in 41 (64%) cases, with an average occurrence of 26 days, while the most frequent systemic complication was fever in 24 cases (37.5%), with an average occurrence of 34 days. Infection of the insertion site occurred in 27 (42.2%) cases and infection of the blood flow associated with the catheter in 30 (49%) cases. Sthaphylococos aureus was the most frequently isolated microorganism in 10 (33.4%) blood cultures. 45 (70.4%) final catheter withdrawals were due to arterio-venous fistula puncture. This analysis revealed various preoccupying aspects, including the catheter permanence time, which highly exposes the patient to different complications, particularly infection.
35

Práticas de enfermagem na inserção, manutenção e remoção do cateter central de inserção periférica em neonatos

Rangel, Regiane Josy Mediote 05 December 2013 (has links)
Made available in DSpace on 2016-08-29T15:38:31Z (GMT). No. of bitstreams: 1 tese_6014_dissertação Regiane Rangel- mestrado enfermagem.pdf: 1219132 bytes, checksum: 553a123acff77348acef8827792df1e5 (MD5) Previous issue date: 2013-12-05 / Uma alternativa de acesso venoso estável, eficaz e muito utilizada em recémnascido (RN) criticamente enfermos na Unidade de Terapia Intensiva (UTIN) é o Cateter Central de Inserção Periférica (PICC). Trata-se de um cateter longo e flexível, inserido através de uma veia periférica que progride até o terço distal da veia cava superior ou veia cava inferior, adquirindo assim propriedade de acesso venoso central. Objetivo: avaliar as práticas de enfermagem na inserção, manutenção e remoção do PICC em RN. Metodologia: Estudo correlacional descritivo transversal retrospectivo. Os dados foram coletados dos prontuários e ficha de acompanhamento do PICC em RN da UTIN de um Hospital Universitário, referentes aos anos de 2009 a 2012. Foram critérios de exclusão: os RN admitidos provenientes de outra instituição com o cateter já inserido; os transferidos para outra instituição com o cateter instalado; os que evoluíram a óbito enquanto usavam o cateter; os que tiveram a inserção do PICC por outro profissional, não enfermeiro. Foram realizadas análises descritivas, o teste t de student, qui-quadrado e ANOVA. O nível de significância adotado foi de 5%. Resultados: a população do estudo foi constituída de 137 RN, principalmente prematuros (67,9%), muito baixo peso (35%) e extremo baixo peso (32,1%). Para a inserção do PICC foram utilizados cateteres 1.9 Fr monolumen de silicone (88,3%) em veias cefálica (41,6%) e basílica (32,1%). O posicionamento inicial da ponta do cateter foi central em 60,6%, principalmente em veia cava superior (34,3%). Ocorreram complicações em 53,3% dos PICC, e as mais comuns foram a obstrução (13,1%), Infitração e/ou extravasamento (12,4%) e exteriorização acidental (8,8%). A média de permanência do PICC foi de 10,5 dias, removidos principalmente por término de terapia (60,3%) e infiltração ou extravasamento (12,5%). O tempo de permanência do cateter foi influenciado pela posição de ponta não central (p = 0,001), complicações (p = 0,014) e remoção não eletiva (p = 0,005). Conclusão: Este estudo proporcionou o conhecimento acerca do estado do uso do PICC e da população que o recebeu na unidade pesquisada. As características encontradas são similares às relatadas na literatura, entretanto destacaram-se o mau posicionamento inicial da ponta do cateter e o número de complicações que determinaram a remoção não eletiva do PICC, demonstrando a necessidade de elaboração de protocolos e rotinas, bem como a realização de programa de intervenção educativa, com vista a garantir a segurança do paciente e a qualidade da assistência de enfermagem aos RN. / A stable and efficient venous access alternative for clinically ill newborns at the Neonatal Intensive Care Unit (NICU) that is frequently used it the Peripherally Inserted Central Catheter (PICC). This is a long and flexible catheter, which is inserted through a peripheral vein progressing to the distal third of the superior cava vein, or the inferior cava vein, acquiring central venous access propertie. Objective: To evaluate the Nursing practices at the insertion, maintenance and removal of the PICC in NBs. Methodology: This is a retrospective transversal descriptive correlational study. Data was collected from the charts and follow-up cards for the PICC in NBs, at the NICU of a University Hospital in the years of 2009, 2011, and 2012. The exclusion criteria were: NBs admited after referral from another institution, with the catheter already inserted; NBs transferred to another institution with catheter already inserted; NBs who have died while using the catheter; NBs who have had the insertion of the PICC done by another professional, and not the Nurse. Descriptive analyses were done, using t Student test, Qui-square test and ANOVA. The significance level adopted was that of 5%. Results: The population of the study was constituted by 137 NB, mainly premature (67.9%), with very low weight (35%), and extreme low weight (32.1%). For the insertion of the PICC, 1.9 Fr silicon monolumen catheters (88.3%) were used, in the cephalic (41.6%) and the basilic (32.1%) veins. The initial positioning of the catheter's tip was central in 60.6% of the cases, most frequently in the superior cava vein (34.3%). There were complications in 53.3% of the PICCs, and the most common of those were; obstruction (13.1%), infiltration and/or overflow (12.4%), and the accidental exteriorization (8.8%). The average permanence of the PICC was of 10.5 days, most commonly removed because of the end of therapy (60.3%), and infiltration or overflow (12.5%). The catheter's permanece time was influenced by the non-central positioning of the tip (p=0.001), complications (p=0.014), and the non-elective removal (p=0.005). Conclusion: This study offered knowledge about the state of the use of the PICC and the population that has received it in the healthcare unit studied. The characteristics found are similar to the ones described in the literature, although the initial malpositioning of the tip of the catheter, as well as the number of complications that determined the non-elective removal of the PICC, were highlighted, showing the need for the creation of protocols and routines, as well as educative intervention programs, in order to guarantee the patient's safety, and the quality of the assistance in NB Nursing care.
36

Revestimento antibiofilme para superfícies de dispositivos médico-hospitalares

Leme, Annelisa Farah Silva Paes 14 February 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-09-04T11:52:25Z No. of bitstreams: 1 annelisafarahsilvapaesleme.pdf: 3714457 bytes, checksum: 04f67b418a9032046d649343f4ef5330 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-09-04T13:18:39Z (GMT) No. of bitstreams: 1 annelisafarahsilvapaesleme.pdf: 3714457 bytes, checksum: 04f67b418a9032046d649343f4ef5330 (MD5) / Made available in DSpace on 2018-09-04T13:18:39Z (GMT). No. of bitstreams: 1 annelisafarahsilvapaesleme.pdf: 3714457 bytes, checksum: 04f67b418a9032046d649343f4ef5330 (MD5) Previous issue date: 2014-02-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Biofilmes associados a dispositivos médicos são responsáveis por 85% das infecções de corrente sanguínea relacionadas a catéteres (ICSRC). O objetivo deste trabalho foi testar duas formulações, como revestimento para catéteres venosos centrais (CVC), as quais tiveram a eficácia antimicrobiana e antiaderente avaliadas in vitro e a eficácia e biocompatibilidade, in vivo. A atividade antimicrobiana foi determinada por método turbidimétrico e a concentração inibitória mínima (CIM) foi estabelecida. A microscopia eletrônica de varredura (MEV) avaliou a propriedade antiaderente dos CVC revestidos com a formulação 1 (CVC-R1) e formulação 2 (CVC-R2), comparados aos não revestidos (CVC-NR). Implantes subcutâneos foram inseridos na área dorsal de ratos. O primeiro ensaio compreendeu análises hematológicas e microbiológicas (hemocultura e colonização das superfícies de CVC), a fim de avaliar a eficácia dos revestimentos. A biocompatibilidade foi avaliada no segundo ensaio pela observação das reações inflamatórias após 7 e 21 dias. Ambas formulações apresentaram atividade antimicrobiana frente a todas as cepas testadas. A desagregação do biofilme, com redução significativa da aderência microbiana, foi observada em ambos CVC revestidos. In vivo, foi observada maior eficácia antibiofilme de CVC-R2, com redução da colonização por Staphylococcus aureus ATCC 25923. As reações teciduais provocadas por CVC-R1 e CVC-R2 foram mais pronunciadas inicialmente, contudo, ao longo do experimento, se tornaram estatisticamente semelhantes às do CVC-NR. Ambas as formulações foram biocompatíveis, com maior velocidade de reparo tecidual no grupo CVC-R2. O uso de CVC- R1 e, especialmente de CVC-R2, pode diminuir a incidência de ICSRC. Acredita-se que CVC-R2 apresenta potencial para ser testado clinicamente. / Device-associated biofilms are responsible for 85% of catheter-related bloodstream infections (CRBSI). The aim of this study was investigate two formulations, as central venous catheters (CVC) coating, which were submitted to in vitro evaluation of antimicrobial and anti-adherent efficacy and in vivo evaluation of efficacy and biocompatibility. The antimicrobial activity was assessed by turbidimetric method and the minimum inhibitory concentration (MIC) was determined. The scanning electron microscopy (SEM) was used to assess the anti-adherent property of CVC coated with formulation 1 (CVC-R1) and formulation 2 (CVC-R2), in comparison to uncoated CVC fragments (CVC-NR). Subcutaneous implants were inserted into the dorsal area of rats. The first assay consisted in hematological and microbiological analysis (hemoculture and CVC surfaces colonization) in order to evaluate the coatings effectiveness. The second assay evaluated the biocompatibility by the observation of inflammatory reactions after 7 and 21 days. Both formulations showed antimicrobial activity against all tested strains. The biofilm disaggregation, with reduction in microbial adherence, was noted in coated catheters. In vivo results showed greater antibiofilm efficacy of CVC-R2 since a reduction of Staphylococcus aureus ATCC 25923 colonization was observed. The tissue reactions of CVC-R1 and CVC-R2 groups were initially more pronounced, however, throughout the experiment, the histological parameters have become statistically similar those found in CVC-NR group. Both formulations were biocompatible and a higher speed of tissue repair in CVC-R2 group was noted. The use of CVC- R1, and especially of CVC-R2, may reduce the development of CRBSI, and thereby, CVC-R2 have potential to be clinically tested.
37

Medidas de bioseguridad en la curación del catéter venoso central por enfermeros de emergencia del Hospital Nacional Daniel Alcides Carrión Callao - 2017

Miranda Contreras, Beatriz January 2018 (has links)
Publicación a texto completo no autorizada por el autor / Determina las medidas de bioseguridad que aplican los profesionales de enfermería en la curación del catéter venoso central. Es un estudio de nivel aplicativo, tipo cuantitativo, método descriptivo de corte transversal. La población está conformada por 20 enfermeros mediante la técnica de observación y la aplicación de la lista de cotejo, previo consentimiento informado. Del 100 % (20), solo 75% aplica las medidas de bioseguridad en la curación del catéter venoso central. Antes del procedimiento 60% aplica y 40% no aplica; durante el procedimiento 20% aplica y 80% no aplica y después del procedimiento 10% aplica y 90% no aplica. Los aspectos que aplican 90% realizan la higiene de manos, 90% la antisepsia de la piel, iniciándose sobre el sitio de inserción del catéter, la zona de unión catéter – piel y la piel adyacente utilizando una gasa estéril impregnada con el antiséptico de elección, y 75% realiza lavado de manos según guía técnica (RM 225-2016); mientras que los aspectos que no aplican 10% no cuentan con el material necesario para la eliminación de desechos biocontaminados, 10% omite realizar la antisepsia de la piel que se inicia sobre la inserción del catéter, así como realizar el lavado de manos según guía técnica (RM 225-2016). / Trabajo académico
38

Diferença do volume presente e requerido de solução para manutenção do cateter venoso central totalmente implantado e fatores associados

Gomes, Alexei Rodrigues January 2013 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2015-12-02T14:01:04Z No. of bitstreams: 1 Alexei Rodrigues Gomes.pdf: 964184 bytes, checksum: d5767e205b935a48ac631790d805cce5 (MD5) / Made available in DSpace on 2015-12-02T14:01:04Z (GMT). No. of bitstreams: 1 Alexei Rodrigues Gomes.pdf: 964184 bytes, checksum: d5767e205b935a48ac631790d805cce5 (MD5) Previous issue date: 2013 / Mestrado Profissional em Enfermagem Assistencial / Introdução: a incidência do câncer cresce no Brasil e no mundo, devido, entre outros fatores, ao aumento da expectativa de vida. A maioria dos tratamentos medicamentosos indicados para os diversos tipos de doenças neoplásicas são feitos por via endovenosa. Para o tempo longo do tratamento, as irritabilidades endoteliais e os danos causados em caso de extravasamento para a região subcutânea, geralmente, é indicada a implantação de cateteres venosos centrais. Estes necessitam ser mantidos pérvios e geralmente usa-se solução fisiológica a 0,9 % com heparina (solução heparinizada) para isto. Observa-se que, na prática diária das instituições que manipulam tais dispositivos, há uma discrepância no que tange ao volume de líquidos a serem introduzidos no interior destes. Assim, este estudo foi norteado pelo seguinte questionamento: qual a quantidade de solução adequada para manutenção do Cateter Venoso Central Totalmente Implantado, tendo em vista as especificidades do cateter e do usuário? Objetivos: verificar a diferença do volume que se usa e o que deveria ser usado para a manutenção desse cateter e que fatores estão associados a essa diferença. Metodologia: pesquisa com abordagem quantitativa descritiva realizada na Unidade I do Instituto Nacional do Câncer, sendo acompanhadas 69 implantações, realizadas por 5 cirurgiões. Para coleta de dados, utilizou-se formulário para levantamento das características do cateter; aplicação de formulário para identificação de dados referentes ao usuário, cirurgião e o procedimento propriamente dito; e formulário de observação não participante. Para os dados referentes à caracterização dos cateteres, elaborou-se uma tabela com tamanhos e respectivos volumes de prime; para o formulário aplicado aos cirurgiões foram elaboradas planilhas com dados para favorecer a análise estatística juntamente com os dados da observação a não participantes e aplicou-se o teste não paramétrico U de Mann Whitney. Resultados: foram encontradas variações entre 0,285 ml a 1,00 ml de volume necessário para o preenchimento do mesmo. A diferença média de volume em mililitros que se usa e que deveriam ser usados foi de cerca de 0,7 ml, tanto para pacientes infantis, quanto para adultos. Conclusão: a quantidade de solução adequada para a manutenção do cateter variou de acordo com o biótipo do usuário e as características dos cateteres, entre outros. Elaboraram-se tabelas com os volumes necessários para preenchimento dos cateteres, levando em consideração os tamanhos e diâmetros dos mesmos / Introduction: The incidence of cancer grows in Brazil and in the world, due, among other factors, to the increase in life expectancy. Most drug treatments indicated for the various types of neoplasic diseases are made intravenously. For the long duration of treatment, endothelial irritabilities, damage in case of leakage into the subcutaneous region are the usual indications for the implantat of central venous catheters. These need to be maintained patent, and generally up to 0.9% saline solution with heparin (heparin solution) is used for this. It is observed that in the daily practice of the institutions that handle such devices, there is a discrepancy with respect to the volume of liquid to be introduced into these. Thus, this study was guided by the following question: What is the appropriate amount of solution to maintain the Totally Implanted Central Venous Catheter in face of the catheter’s and patient’s specificities? Objectives: To investigate the difference of volume that is used and what should be used for the maintenance of the catheter, and what are the factors related to this difference. Methodology: A quantitative descriptive Survey carried out in Unit I of the National Cancer Institute, following 69 insertions performed by 5 surgeons. For data collection, a form was used to assess the catheter’s characteristics, a form to identify data about the user, the surgeon and the procedure itself; and a form for non-participant observation. A table with the sizes and the volume of prime is presented. Worksheets with data about the surgeons was created to prompt the statistical analysis, as well as data of non-participating observation. The nonparametric Mann-Whitney U test was applied. Results: Variations between 0.285 ml to 1.00 ml of volume were found to be required to fill the catheter. The average difference in volume that is used and that which should be used was of about 0.7 ml for both children and adult patients. Conclusion: The appropriate amount of solution to maintain the catheter varied depending on the biotype of the patient and the features of the catheters. Tables were prepared with the data about the required volumes to fill the catheter, taking into account their size and diameter

Page generated in 0.055 seconds